800SVRM-7 5/04 RATE-OF-FLOW CONTROL 800 SERIES CONTROL VALVES

Similar documents
PRESSURE CONTROL 800 SERIES CONTROL VALVES

Holding. Resistance. Inrush. Watts. Amps. Amps. (ohm)

PRESSURE REDUCING VALVE

PRESSURE REDUCING VALVE

ELECTRIC & HYDRAULIC VALVES

PRESSURE REDUCING CONTROL VALVE

Mustang Series PRESSURE REDUCING CONTROL VALVE. M115 (Globe) M1115 (Angle) Schematic. Standard Components. Options & Accessories.

PRESSURE REDUCING VALVE

200 Series - Plastic Hydraulic/Electric Control Valves. Water Control Solutions

PERFORMANCE & DIMENSIONS SECTION 3

50-01 (Full Internal Port) (Reduced Internal Port) Pressure Relief. & Pressure Sustaining Valve MODEL

LEAD FREE * LFF115 (Globe) LFF1115 (Angle)

800 SERIES control valve accessories guide

Pneumatics, Automation & Control Solutions

LEAD FREE * LFM115 (Globe) LFM1115 (Angle)

NYLON & PVC VALVES MINING DIVISION PRESSURE REDUCING VALVES ENSURE DOWNSTREAM PRESSURE PVC NYLON

PARTS & ASSEMBLY DRAWINGS SECTION 1. Jacket

800 Series Control Valves

Deep Well Pump Control Valve

Tekleen LPF USERS AUTOMATIC FILTERS, INC. MANUAL

Test Which component has the highest Energy Density? A. Accumulator. B. Battery. C. Capacitor. D. Spring.

BERMAD Waterworks. Pressure Relief/Sustaining Valve. Model: WW Series. Features and Benefits. Major Additional Features

Pilot Valves Catalogue

Cla-Val. Service Training Manual. Simple solutions plus learning with a purpose

Check Valves Check Valves are the simplest form of directional control valves, but they can also be used as pressure controls.

Booster Pump Control Valve

SERIES Waterman* DESCRIPTION FLOW PRESSURE PAGE NO.

TECHNICAL VALVES PRINCIPLE OF OPERATION DOROT PLASTIC VALVES. 3-Way Control System. 2-Way Control System T48

HYDRAULIC CONTROL VALVES

EZH and EZHSO Series. Pressure Reducing Regulators. EZH and EZHSO Series. Introduction. Scope of the Manual. Product Description !

DOROT CONTROL VALVES CATALOGUE

DWS 41. Installation Data 44 Performance Specs DWS & DW-PRV Series

Sanitary Turbine Flow Meter - TA3 Installation, Operating & Maintenance Manual

Introduction. System Components

To ensure proper installation, digital pictures with contact information to before startup.

BERMAD Irrigation. IR-300 Basic Valve. 300 Series. ??????? Basic Valve

Series 44 Installation Instructions

OBSOLETE DOCUMENT. PRX Series Pilots for Pilot-Operated Pressure Reducing Regulators. PRX Series. Introduction. Product Description

Tekleen ABW USERS AUTOMATIC FILTERS, INC. MANUAL

Wet pipe low flow foam/water manifold system

1000 SERIES VALVES & TWIG WIRELESS CONTROLS

April 2004 / BULLETIN for Supermarket Systems DDR-20 OLDR-15

TR-QS Wafer-Style Turbine Flow Meters Installation, Operating & Maintenance Manual

Flow Control & Pressure Reducing Valve with Hydraulic Control (Sizes 3''- 12"; DN80-DN300)

CATALOGUE AUTOMATIC CONTROL VALVES

LOAD SENSE SECTIONS. Series 20. Directional Control Valves NEED NEW PIC VALVES STANDARD FEATURES SPECIFICATIONS

Adjustable Differential Relay A1

Series 500 Valves. Product Catalogue. Series 500 Valves. Series 500 Valves. Catalogue. Edition 10/2012

Operator's Manual. Models (¾") (1") (1½ ) (2 ) (3") (4") (6") (8")

Daniel. Liquid Control Valves Technical Guide. Technical Guide DAN-LIQ-TG-44-rev0813. DAN-LIQ-TG-44-rev0208. February 2008.

Super Gal. Super Gal. Model 75 - High Capacity Plastic Control Valve. Product Catalogue. Super Gal Catalogue. Model 75.

Float Valve MODEL. Schematic Diagram. Optional Features. Typical Applications. Installation. Product Dimensions Data:

Check List for Optimal Filter Performance

WATERWORKS. Reach Optimum Efficiency with OCV Control Valves.

LogSplitterPlans.Com

INSTALLATION, OPERATION AND MAINTENANCE Threaded and Wafer Style Flowmeters

List prices are for individual parts See following pages for illustration of parts by number

3-Way heavy duty flow control, with pressure compensated, solenoid and load sensing controlled priority flow

Solenoid valve. Solenoid Coil

and RD5000 or by the Utility section in the Series 20 valves. 7. The internal pilot pressure is used to initiate the spool shift when a solenoid is en

SECTION ELECTRONIC ACTUATED PRESSURE REDUCING VALVES AND ACCESSORIES

SERIES 14 INSTALLATION INSTRUCTIONS and field service check list

(770) Turning Parts Changers Into TROUBLESHOOTERS!

ME 360 Test #3 Spring 08 5/5/08. Closed book, closed notes portion of test. Total of 25 out of 100 points for questions #1 to #6.

BERMAD Irrigation. High Performance Plastic Valves. 100 Series - Water Control Solutions

Product Catalogue. Series 75 Valves. Valves. Catalogue. Series 75. Edition 09/2017

t2_ il PioC Oper. led Relet Valve Symbol ~~~ CHAPTER 12 Pilot Operated Pressure Control Valves

Flow Control Valve IOM 770-U

Types 1098-EgR and 1098H-EgR Pressure Reducing Regulators

Structural Simplicity and Superior Hydraulic Performance. Valve Operation Guide

GPM Hydraulic Consulting, Inc. P.O. Box 689. Social Circle, GA Hydraulic Consulting, Inc

Valve Operation Guide

Pilot Oil Supply Circuit

specification DAtA V R0 pilot operated tank blanket VAlVe, pressure regulating VAlVe SERIES V500

Type 310A-32A Pressure Reducing Regulator

Pilot-Operated Regulators

General Valve Assembly Information

TECHNICAL PAPER 1002 FT. WORTH, TEXAS REPORT X ORDER

BASIC FOAM FIREFIGHTING OPERATIONS Red and Green Systems

Series Roll Seal

AVIATION FUELING CONTROL VALVES

FLOOD PROTECTION SHUT DOWN VALVE (3 and smaller)

The full WeatherTRAK Flow3 Installation and Maintenance Manual is available online at

P99 Pressure Reducing Regulator

Booster Pump Control Valve

To ensure proper installation, digital pictures with contact information to before startup.

611H Flo-Con Pressure Regulators & Valves

Mark 5108 Series. Back Pressure Regulating Valves Mark 5108 Series. Back Pressure Regulating Valves. Valve Features. Operation

AgXcel GX5 Install Guide for Integration into Trimble. where precision meets the soil... PO Box 1611 Kearney, NE

DELUGE VALVE MODEL: SD-DVA TECHNICAL DATA : VALVE OPERATION TRIM DESCRIPTION DESCRIPTION PRESSURE THREADED OPENING

Model 1100 Turbine Flow Meter

Pressure Control Valves

WARCO CHEMAG SERIES GH FILTERS

IOM IR-910M0-X. Hydrometer Magnetic Drive with solenoid control

Exercise 4-1. Flowmeters EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION. Rotameters. How do rotameter tubes work?

GROUP 11 HYD. PUMPS & VALVES

Differential Piston Control Valves Pressure, Level and Flow Control

BERMAD Irrigation. Hydraulic Control Valves 900 series - Hydrometers. Water Control Solutions

Causes and Cures of Regulator Instability

2000 Series Heavy-Duty Irrigation Valves Recommended Applications Golf Courses Landscapes Parks Right-of-ways

Transcription:

RATE-OF-FLOW CONTROL

RATE-OF-FLOW WITH SOLENOID & EXTERNAL FILTER.2

.3

RATE-OF-FLOW & PRESSURE REDUCIN G WITH SOLENOID & EXTERNAL FI LTER.4

RATE-OF-FLOW & PRESSURE SUSTAINING WITH EXTERNAL FILTER.5

RATE-OF-FLOW WITH SOLENOID & EXTERNAL FILTER.6

RATE-OF-FLOW & PRESSURE REDUCING WITH SOLENOID ACTUATED HYD. RELAY & EXT. FILTER SOLENOID ENERGIZED: RATE-OF-FLOW CONTROL LIMITS THE FLOW RATE PASSING THROUGH THE VALVE. RATE-OF-FLOW CONTROL IS SET TO 110-120% ABOVE SYSTEM FLOW RATE. DURING SYSTEM FILLING, RATE-OF-FLOW CONTROL WILL RESTRICT FLOWRATE TO DESIRED SETPOINT. AS DOWNSTREAM PRESSURE RISES TO PRESSURE REDUCING SETTING, THE CONTROL AUTOMATICALLY SHIFTS TO PRESSURE REDUCING REGULATER TO HOLD A CONSTANT OUTLET PRESSURE REGARDLESS OF VARYING INLET PRESSURE AND/OR CHANGING FLOW RATE. SOLENOID DE-ENERGIZED: THE VALVE WILL CLOSE. H2 9408 - EXTERNAL FILTER KIT SIGNAL PORT MODEL # D2 D3 D4 D11 D12 D13 D18 E24 E45 H2 D18 9778-001 8" RATE-OF-FLOW CONTROL REMOTE(900-3800 GPM) D18 9778-002 8" RATE-OF-FLOW CONTROL IN-VALVE(900-3800 GPM) D18 9778-003 6" RATE-OF-FLOW CONTROL REMOTE(500-2000 GPM) D18 9778-004 6" RATE-OF-FLOW CONTROL IN-VALVE(500-2000 GPM) D18 9778-005 3" RATE-OF-FLOW LO-FLO CONTROL REMOTE(120-400 GPM) D18 9778-006 4" RATE-OF-FLOW LO-FLO CONTROL REMOTE(200-540 GPM) D18 9778-007 6" RATE-OF-FLOW LO-FLO CONTROL REMOTE(330-1010 GPM) D18 9778-008 8" RATE-OF-FLOW LO-FLO CONTROL REMOTE(490-1530 GPM) GPM 2000 1800 NELSON IRRIGATION CORPORATION E24 E45 #6 RESTRICTOR FLOW DIRECTION DWNSTRM VALVE - SOLENOID VALVE KIT VENT UPSTREAM SOLENOID COIL 8980 - MANUAL SELECTOR VALVE KIT THREAD INTO CONTROL CHAMBER NORMALLY CLOSED 2RN PLUG UPSTRM BACCARA 3W NO 1.2 VOLTAGE NORMALLY OPEN A U E T O C L OS O N E P COMMON DOWN STREAM VALVE NELSON IRRIGATION CORPORATION 200 PSI TO BYPASS THE SOLENOID SELECT "OPEN" AND THE VALVE WILL REGULATE. VENT DOWNSTREAM D2 9529-001 PRESSURE-REDUCING KIT 5-50 PSI (.3-3.4 BAR) D3 9529-002 PRESSURE-REDUCING KIT 10-120 PSI (.7-8.3 BAR) D4 9529-003 PRESSURE-REDUCING KIT 25-200 PSI (1.7-13.8 BAR) SMALL PILOT FOR 2" AND 3" VALVES D11 9691-003 PRESSURE-REDUCING KIT 3-25 PSI (.2-1.7 BAR) D12 9691-001 PRESSURE-REDUCING KIT 5-50 PSI (.3-3.4 BAR) D13 9691-002 PRESSURE-REDUCING KIT 10-120 PSI (.7-8.3 BAR) VALVE SIZE 2 INCH 3 INCH 4 INCH 6 INCH 8 INCH TUBING SIZE.7

RATE-OF-FLOW INTEGRAL WITH VALVE Installation Instructions for the Model D18 Rate-Of-Flow Control In order to minimize the risk of shipping damage, the model D18 Rate-Of-Flow Control is removed from its 800 Series control valve prior to shipment. Follow these steps to install the Rate-Of-Flow control: 1. Remove all packaging material and note the direction of the flow arrows on the 800 Series valve and the Rate-Of-Flow Control. 2. Thread the Rate-Of-Flow Control into the sensing paddle housing. 3. Connect the control tubing marked 1 to fitting 1 and 2 to fitting 2 (see Figure 1). 4. Install the 800 Series valve in the line. Connect at These Points 2 1 First-Time Start-Up Adjust Before Tightening Jam Nut 1. Set the Rate-Of-Flow adjustment screw to its minimum setting to fill the system slowly. 2. After the system is full and operating, turn the Rate-Of-Flow adjusting screw to increase the 1 flow rate as desired. Read the flow scale with 2 the jam nut out of the way. (Go to step 4 if no other pressure control is used on the valve.) Flow Sensing Flow Direction 3. If a pressure reducing control is also on the Paddle valve, set the Rate-Of-Flow 10-20% higher than normal operating flow. The next time the system 5 Diameters 800 Series Valve is started, the valve will automatically open to the Rate-Of-Flow set point. When normal operating flow Figure 1 is reached, the pressure reducing pilot will take over. To determine which of the two pilots is controlling the valve, feel for pressure on the number 2 tubing line while the valve is flowing (see Figure 2). To find if the Rate-Of-Flow is set Look Here for too low, push on the tube in the direction shown in Figure 2. Ring Movement If the tube has pressure the ring will not move easily, indicating that the Rate-Of-Flow has control of the valve. Turn the 2 adjusting screw in more to give control to the pressure reducing pilot. If the ring moves easily into the fitting, the pressure reducing control is in control of the valve. Read the scale on the adjustment screw with the jam nut out of the way. Tighten the jam nut to lock-in the setting. 4. Fine tune the setting and determine the system response to the valve using a flow meter and pressure gages. Figure 2 Performance Note The Rate-Of-Flow Control works by means of a flow-sensing paddle on the upstream side of the valve. For better valve operation and accuracy, avoid pipe size changes, flow meters, pumps and elbows upstream of the Rate-Of-Flow valve. A straight length of pipe five pipe diameters long helps take out the turbulence and will improve the valve performance. The Rate-Of-Flow is not intended to replace a flowmeter..8

800SVRM-9 12/09 Rate-Of-Flow installed on Nelson Flanged Pipe Spool Follow these steps to install and setup the Rate Of Flow on a pipe: 1. Remove all packaging material and note the direction of the flow arrows on the flanged pipe spool and the Rate Of Flow. 2. Thread the Rate Of Flow control into the sensing paddle housing. 3. Connect the control tubing marked 1 to the upstream fitting 1, and the control tubing marked 2 to fitting 2 (see Figure 3) and vent at the points shown by the arrows in the sketch. 4. Install the flanged spool and 800 Series valve. Follow steps 3 and 4 in "First Time Start Up" and try to avoid upstream turbulence as noted above. Flow Sensing Paddle Connect at These Points Adjust Before Tightening Jam Nut Connect to Upstream 2 1 1 Threaded Outlet Connect to Valve Chamber Flow Direction Flanged Pipe Spool 800 Series Valve Figure 3 Pump Control Valve using Rate-Of-Flow Control The Nelson 800 Series Pump Control Valve using Rate-Of-Flow control is an automatic valve designed to be installed on the discharge side of a pump to prevent surges due to rapid opening of the valve. It is a solenoid operated valve designed to be used with a flow sensing paddle. The 3-way solenoid either applies upstream pressure to the sleeve control chamber to close the main 800 Series valve or vents the sleeve control chamber to atmosphere allowing the main 800 Series valve to open. 1. The solenoid is synchronized with the pump controls to allow the pump to start and stop while the valve is closed thus eliminating any pressure surges. 2. The pump starts against a closed valve which begins to open slowly as the solenoid is energized with the pump. 3. Finally, the 800 Series valve opens full to allow maximum flow with minimal head loss. 4. When finished, the pump is signalled to stop, the solenoid is de-energized causing the main valve to close against the still running pump. The solenoid can be supplied with various operating voltages..9