UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Similar documents
Master DIALOG INDUSTRY RANGE

Master Plus kva

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

UPS Multi Sentry 10-20kVA

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Master MPS kva kva 3:1 3:3 VFI TYPE

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS kva kva 3:1 3:3 VFI TYPE

Master Plus kva

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

Technical Data Sheets

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Data Sheets

UPS Multi Power 1-28 x 42 kw up to 1MW

TECHNICAL DATA SHEET KVA UPS Systemss

Technical data sheets

Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

Technical Data Sheets

HAIRF UPS. X5 Series KVA

MKN-DSP SERIES - THREE PHASE

Technical Data Sheets

SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

Technical Data Sheets

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Technical Data Sheets

SR series. on-line

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

POWER kva

POWER kva

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Data Sheets

EFFEKTA Power Supplies

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

Technical Data Sheets

PowerValue 11/31 T kva

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

POWERTRONIX QUASAR 5-40 KVA

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

Industrial PFC UPS System

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

TLE Series UPS 400/500 kw With eboost Technology

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

YOUR POWER IN SAFE HANDS. E Series UPS

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

SENTINEL VA

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

TLE Series UPS 160/200/225/250 kw with eboost Technology

» Sophisticated» Reliable» Intelligent

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Three Phase UPS Systems Range: 10 to 500kVA

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

D Series: UPS UPTO - 300KVA - Three / Three Phase

60 to 160 kva.

SitePro UPS 400Vac / CE. GE Consumer & Industrial August 2004

UPS. MODULAR from 10 to 60kVA THE GLOBAL SPECIALIST IN ELECTRAL AND DIGITAL BUILDING INFRASTRUCTURES

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

1.1 GENERAL CHARACTERISTICS

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

PowerWave 33 Efficient power protection for today s IT and process-related work environments

Aurora Single Phase Emergency Lighting Inverters

SmartOnline SUT Series 3-Phase 208/120V 220/127V 40kVA 40kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

ConceptpowerTM Modular kVA

PowerScale TECHNICAL SPECIFICATIONS

APC Smart-UPS RT. GUIDE SPECIFICATIONS FOR 2400VA and 3000VA Smart-UPS RT 100 and 120VAC Uninterruptible Power Supply

PowerScale kva Technical Specifications

MGE TM Galaxy TM 7000 GFC

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

UNIVERSITY OF CALCUTTA Centre for Research in Nanoscience and Nanotechnology JD-2, Sector-III, Salt Lake City Kolkata

On-line, Single Phase, Double Conversion UPS

TLE Series UPS 750/1000 kw With eboost Technology

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

Liebert. FP 50Z kva

S2000 PRODUCT RANGE. Ultra compact

Technical Data Sheet. Uninterruptible Power Supply. Critical Power. imagination at work

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

SmartOnline 3-Phase In/Out 120/208V 20kVA 16kW On-Line Double-Conversion UPS, Extended Run, SNMP, Webcard, Tower, DB9 Serial, Hardwired

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION SYSTEM DESCRIPTION... 4

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

Transcription:

SENTRY HPS HM/HT provides maximum protection for vital mission-critical networks, security applications (electro-medical) and industrial applications thanks to its outstanding mechanical and electrical design. The load is powered continuously by the inverter with a filtered, stabilized and regulated sine wave supply. The input and output EMI filters considerably increase the immunity of the load to mains disturbances and surges. The SENTRY HPS HM/HT series uses on-line double conversion technology (VFI) with an isolation transformer on the inverter output. SENTRY HPS HM/HT is supplied with Watch&Save 3000 software as standard and can be remotely monitored using the PowerNetGuard system from anywhere in the world. Additional battery extension packs allow the standard battery runtime to be extended up to several hours. Minimum Impact on Supplies - Easy Source Input current distortion <4% for the with filter with sinusoidal absorption to remove the risk of resonance with other input supply users or phase shift capacitor sets. The absorbed current distortion is independent of input supply parameters such as impedance. This enables to deliver maximum performance levels regardless of the installation environment. With these input features Sentry HPS can achieve significant savings in terms of sizing and power supply sources - isolation transformers and generators over less sophisticated power systems. Maximum Battery Care Battery deep discharge protection Temperature compensating charger Built-in automatic and manual battery test feature Simple to Install Capability to install the UPS into any distribution system (neutral not required on rectifier input) Capability to separate the rectifier/bypass power networks and to power these from two separate sources, without Galvanic isolation Illustrative photo A2B, s.r.o., Horská 1, SK 010 03 Žilina Považský Chlmec 1 / 5

High Reliability Extremely high shortcircuit current to ensure compatibility with the most difficult transformer applications (lighting, drives and industrial processes) and an isolation transformer on the inverter output Full microprocessor control with no-break static and manual bypasses IGBT technology Other Characteristics 0.8 power factor makes suitable for powering ICT and industrial loads High level diagnostics: event log with 128 messages, states, measurements and alarms - available from the built-in LCD in several languages BACK FEED protection: to avoid energy feeding back into the mains supply should a fault occur Options Isolation transformers Various lead acid battery types including 5 year, 10 year and 20 year design life, VRLA, NiCad options and runtimes up to several hours Communications software Solutions for low input current distortion Closed loop parallel kit option (to be ordered with the unit) Low consumption levels can achieve efficiencies >98% thanks to a selectable Economy Mode which can be used in stable electrical environments to provide power supply continuity should the mains fail. UPS Maximum Reliability and Availability Connect up to 8 units in parallel or N+1 redundancy, even of different power ratings. The UPS continue to work in parallel even if one of the interconnecting communication cables is disconnected (CLOSED LOOP). Advanced Communication Compatible with TeleNetGuard for remote maintenance Advanced, multi-platform communication for all operating systems and network environments: Watch&Save 3000 monitoring and shut-down software included, with SNMP agent, for Windows 9x, ME, NT 4.0,2000, XP, Vista and 2003 server; Mac OS X, Linux, Novell and Unix operating systems The UPS is supplied with a cable for direct connection to the PC (Plug and Play) RS232 serial por Dry contacts Installation slot for an Emergency Power Off (EPO) interface to allow the UPS to be switched off remotely in an emergency. Installation slot for connecting auxiliary contact bypass LCD or LED remote control panel Graphic panel for remote control Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and frequency variations. The interface also enables more economic use of the battery charger. No-break power architectures The range features a wide range of modules and configurations that can be manufactured into one complete system to solve your power problems. Each system is therefore unique and we ask that you consult our engineers for your specific application. Application Servers Local Area Network (LAN) Data centers Telecommunications Industrial equipment Electro-medical equipment Illustrative photo A2B, s.r.o., Horská 1, SK 010 03 Žilina Považský Chlmec 2 / 5

Technical Data Three-phase input Single-phase output Models HM8 HM10 HM15 HM20 HM30 HM40 HM60 HM80 HM100 Power (kva) 8 10 15 20 30 40 60 80 100 Input HM8 HM10 HM15 HM20 HM30 HM40 HM60 HM80 HM100 400 Vac three-phase + N Voltage range ± 20% Frequency range 45 65 Hz Power factor > 0,92 with harmonic filter Current harmonic distortion < 5% with harmonic filter Soft start 0 100% in 10 By-pass HM8 HM10 HM15 HM20 HM30 HM40 HM60 HM80 HM100 230 Vac 1-fáza Permitted voltage range ± 15% (selectable from ± 10% to ± 25%) Rated frequency 50 / 60 Hz Permitted frequency range ± 2% (selectable from ± 1% to ± 5%) Standard features BackFeed protection; split bypass line Batteries HM8 HM10 HM15 HM20 HM30 HM40 HM60 HM80 HM100 Type VRLA AGM / GÉL; NiCd Maximum recharge current (A) 0,2 x C10 AC ripple voltage < 1% Output HM8 HM10 HM15 HM20 HM30 HM40 HM60 HM80 HM100 (kva) 8 10 15 20 30 40 60 80 100 Active power (kw) 6,4 8 12 16 24 32 48 64 80 230 Vac (single-phase) Regulation of the output voltage 220 244 Vac phase/neutral Crest factor 3 : 1 Distortion 2% (linear load) Static stability ±1% Dynamic stability ±5% Frequency 50 / 60 Hz (configurable) Overload 110% / 125% / 150% of the rated current for 5h / 10 min / 1 min Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5%) with mains supply present System HM8 HM10 HM15 HM20 HM30 HM40 HM60 HM80 HM100 Weight (kg) 190 200 220 230 290 340 440 520 650 Dimensions (wdh) (mm) 555x720x1200 800x740x1400 1070x740x1400 Remote signalling Dry contact Remote controls EPO and Bypass Communication 2 x RS232/C + remote contacts Operating temperature 0 C +40 ºC, optimal +15 C / +25 C Humidity < 95% non condensing Noise 54 dba 60 dba 65 dba at 1m Protection degree IP20 Efficiency >91% >92% Compliance EN 62040-1; EMC EN 62040-2; Smernice 73/23/EC, 93/68/EC, 89/336/EC, EN 62040-3 A2B, s.r.o., Horská 1, SK 010 03 Žilina Považský Chlmec 3 / 5

Technical Data Three-phase input Single-phase output Models HT10 HT15 HT20 HT30 HT40 HT60 HT80 Power (kva) 10 15 20 30 40 60 80 Input HT10 HT15 HT20 HT30 HT40 HT60 HT80 400 Vac 3-fázy + N Voltage range ± 20% Frequency range 45 65 Hz Power factor > 0,9 with harmonic filter Current harmonic distortion < 5% with harmonic filter Soft start 0 100% in 10 By-pass HT10 HT15 HT20 HT30 HT40 HT60 HT80 400 Vac three-phase Permitted voltage range ± 15% (selectable from ± 10% to ± 25%) Rated frequency 50 / 60 Hz Permitted frequency range ± 2% (selectable from ± 1% to ± 5%) Standard features BackFeed protection; split bypass line Batteries HT10 HT15 HT20 HT30 HT40 HT60 HT80 Type VRLA AGM / GÉL; NiCd Maximum rechard current (A) 0,2 x C10 AC ripple voltage < 1% Inverter output HT10 HT15 HT20 HT30 HT40 HT60 HT80 Rated power (kva) 10 15 20 30 40 60 80 Active power (kw) 8 12 16 24 32 48 64 Number of phases 3 + N 400 Vac (selectable) Regulation of the output voltage 348 424 Vac phase/neutral Crest faktor 3 : 1 Static stability ±1% Dynamic stability ±5% Frequency 50 / 60 Hz (selectable) Overload n 110% / 125% / 150% of the rated current for 5h / 10 min / 1 min Frequency stability ± 0,05% on mains failure ± 2% (selectable from ± 1% to ± 5%) with mains supply present System HT10 HT15 HT20 HT30 HT40 HT60 HT80 Weight (kg) 210 480 220 490 230 500 282 552 330 450 555 Dimensions (whd) (mm) 555 x 720 x 1200 800 x 740 x 1400 Remote signalling Dry contact Remote controls EPO and Bypass Communication 2 x RS232/C + remote contacts Operating temperature 0 C +40 ºC, optimal +15 C / +25 C Relative humidity < 95% non condensing Color Light grey (RAL 7035) Noise 54 dba / 1m 60dBA / 1m 62dBA / 1m Protection IP20 Efficiency >90% >91% >92% Compliance EN 62040-1; EMC EN 62040-2; Smernice 73/23/EC, 93/68/EC, 89/336/EC, EN 62040-3 Internal batteries Yes Yes Yes Yes None None None A2B, s.r.o. reserves the right to change any specifications without prior notice. A2B, s.r.o., Horská 1, SK 010 03 Žilina Považský Chlmec 4 / 5

A2B, s.r.o., Horská 1, SK 010 03 Žilina Považský Chlmec 5 / 5