PowerCore Dust Collectors Series CPC

Similar documents
DCE 2000 Series Dust Collectors

Unicell Dust Collectors Series C10-90

Unimaster Dust Collectors Series UMA

Unicell Dust Collectors Series C required for. required for maintenance. Controller j

Unimaster Dust Collectors Series UMA

Dalamatic Insertable Dust Collectors Series DLM V

Dalamatic Cased Dust Filters Series DLM 15

Dalamatic Cased Dust Collectors Series DLM 15

DCE 100 Series Dust Filter

DCE 100 Series Dust Filters

Unimaster Dust Collectors Series UMA

Installation, Operation and Maintenance Manual. EVC Controller (from February 2007)

PowerCore Dust Collectors

POWERCORE SMAllER. SMARTER DuST COllECTORS.

Dalamatic Concept Dust Collectors Series D60-225

Dalamatic Dust Collectors

DALAMATIC DUST COLLECTORS

Unicell Dust Collectors

DUST COLLECTORS DOWNFLO OVAL

Powercore Smaller. Smarter

Unicell. Filtration Engineered for Performance

TORIT POWERCORE DUST COLLECTORS TG SERIES. Silver Award

Small centrifugal fans made of plastic

Continuous Baseload. Prime Power

VARIO. VARIO Separation of fine dust particles. The VARIO series is particularly suitable for separation of fine dust.

PACKAGED DOWNFLO EVOLUTION DUST COLLECTORS. The Complete Plug-and-Play Solution

Torit PowerCorE. VH Series

XLR TM. Next generation air filtration

4016TAG1A 4016TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Ratings. Basic technical data

Centrifugal fan with highly efficient EC drive motor

Downflo Systems. Containment. With Triple-Sealed Bag-In/Bag-Out for filters and hopper discharge

DOWNFLO OVAL DUST COLLECTORS HIGH VACUUM DFO2-4

Technical Data 4008TAG 4008TAG1 4008TAG Series. Diesel Engine - ElectropaK

TAG2A TAG3A. Series kwm 1500/1800 rpm kwm 1500/1800 rpm ElectropaK. Ratings. Basic technical data

BULLETIN 456. July 1997 VANEAXIAL FANS. Type W Direct Drive/Belt Driven. Model VW Direct Drive. Model VWBD Belt Driven

TORIT POWERCORE DUST COLLECTORS TG SERIES

Ratings TAG2A (1500 rpm)...1: TAG2A (1800 rpm)...1: TAG3A (1500 rpm)...1: TAG3A (1800 rpm)...

TORIT POWERCORE DUST COLLECTORS TG SERIES

TORIT POWERCORE DUST COLLECTORS TG SERIES. Silver Award

TORIT POWERCORE DUST COLLECTORS

FILTRATION TECHNOLOGY PHARMACEUTICAL, NUTRACEUTICAL, & COSMETIC INDUSTRIES

INSTALLATION AND OPERATION MANUAL

ULTRA-WEB HIGH EFFICIENCY NANOFIBRE FILTERS

Torit powercore. tg series. Silver Award

DOWNFLO EVOLUTION DUST COLLECTORS

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting K

1104D-44TG2 1104D-44TG kwm 1500/1800 rpm. ElectropaK. Series. Basic technical data. Performance

Our older, classic EBA cowl-mounted air cleaner (shown on the right) has been replaced with our ERA Air Cleaner.

DOWNFLO OVAL DUST COLLECTORS

Bifurcated Case Axial Fans (BIFA)

Downflo. Oval Dust Collectors POWERED BY

Affordable portable filtration unit

Off-line filter / cooler unit FGSL

Type MSA. Splitter thickness 200 mm FOR INCREASED INSERTION LOSS AND BROADBAND ATTENUATION EVEN IN THE LOW FREQUENCY RANGE

TORIT POWERCORE DUST COLLECTORS TG SERIES

Air Boss CA3000C & CA6000C. Installation Operation Maintenance Manual. Cartridge Air Cleaners

Technical Data. 400 Series 403D-15G. ElectropaK

AXIAL FANS Catalogue CN0050C01 May 2008

Medium Pressure Centrifugal Fans

PRELIMINARY. Engine Speed Standby Power Prime Power Continuous Power. RPM kwm BHP kwm BHP kwm BHP. Litre / hour

FilterMax DF. Modular dust multi purpose collector. Models

Oil/air cooler BLK ATEX-3GD


Vent-Axia Sabre Sickle Roof Fans (VSR)

CA3000C & CA6000C Cartridge Air Cleaners

Technical Data TWG2A TWG3A Series. Diesel Engine - ElectropaK rev/min. Basic technical data

FilterMax DF. Modular dust multi purpose collector. Models

Oil-injected. Installed motor power kw/ hp Free air delivery from 0.47 to m³/min, Pressure 3-40 bar CONTENTS

Cummins and Fleetguard are registered trademarks of Cummins, Inc. Mann+Hummel is a registered trademark of Mann+Hummel GMBH

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

NCF fans 50 Hz. Protection class IP 55

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS SERIE BV

Datasheet. Flamcomat - Pressureless Expansion System

Performance. Perkins Engines Company Limited. Perkins Engines Company Limited. Peterborough PE1 5FQ United Kingdom Tel: +44 (0)

CAV controllers. Type RN-Ex. For the precise control of constant volume flows in potentially explosive atmospheres (ATEX) PD RN-Ex 1

FIXED DISPLACEMENT HYDRAULIC VANE PUMPS BV SERIES

VORTICENT C E RANGE Centrifugal fans

Check out your benefits: Screw compressors S series

CAV controllers. Type VFL. Volume flow limiter for insertion into ducting PD VFL 1

1106A-70TAG4. Series kwm 1500 rpm ElectropaK. Basic technical data. General installation

1506A-E88TAG5. Series. 293 kwm 1500 rpm 333 kwm 1800 rpm. Basic technical data

Square Duct Fans - ESTOC TARGE Range. Estoc Targe Features. Electrical Supply. Sizes 355, 400, 450, 500, 560 and 630.

CAV controllers. Type EN-Ex. For the precise control of normal and high constant volume flows in potentially explosive atmospheres (ATEX)

abc CPD7948/075 Rotors, rotor shafts and rotor casings are coated with an anti-corrosive and anti wear coating to prolong element life and efficiency.

TAG3. Diesel engine - ElectropaK. Series kwm 1500 rpm. Basic technical data. Ratings. Total weight of ElectropaK

Dryflo Mist Collectors

FilterMax F. Modular dust collector with integrated pre-separator. Models

@Perkins. Technical Data. 400 Series 403D-11G. ElectropaK

DOWNFLO OVAL DUST COLLECTORS

Copyright CBR - HEIDELBERGCEMENT GROUP FILTRATION SOLUTIONS FOR MINING & MINERAL INDUSTRY

@Perkins. Technical Data Series TAG1A TAG2A TAG3A. Diesel Engine - Electropak. Basic technical data

Portable filtration unit / 650 CFM (305 L/s) Portable filtration unit / 1500 CFM (710 L/s) For 1 or 2 arms configuration

Mixed Flow Roof Fans (RMH)

Square Duct Fans - ESTOC Range. Estoc Features. Electrical Supply. Product Code. Sizes 355, 400, 450, 500, 560, 630 and 710.

4008 TAG1A 4008 TAG2A. Series kwm 1500 rpm kwm 1500 rpm ElectropaK. Basic technical data.

Air Motors to 3.9 hp (0.16 to 2.9kW) Comprehensive range Lubrication free Stainless steel High torques. More Than Productivity

Shut-off dampers. Type AK-Ex. For low-leakage shut-off of volume flows in potentially. explosive atmospheres (ATEX) PD AK-Ex 1.

RA / Internal Gear Pump Model GP2, Series 2X Fixed Displacement. Typical application:

Vane Pumps. VMQ Series Vane Pumps For Industrial and Mobile Applications Displacements to 215 cm 3/ r (13.12 in 3 /r) Pressures to 260 bar (3800 psi)

Underground Tank Applications Installation Guide

Transcription:

PowerCore Dust Collectors Series CPC PowerCore dust collector with dust container (without fan). (CPC-6 illustrated). Suitable for inside locations and outside when fitted with optional weather cowl. 600 required for maintenance A j h n 0 minimum clearance 500 required for maintenance B 500 required for maintenance Cleaned air outlet Hinged access door Compressed air inlet ½" BSP Parallel (may be fitted either side) m k p C without optional explosion relief (as illustrated) D with optional explosion relief Manometer connections Controller Contaminated air inlet E 80 litre dust container q F G Filtration Number Type area of filter (Ultra-Web ) packs Inlet spigot DIMENSIONS in mm (inside dia.) A B C D E F G h j k m n p q CPC-3 18.6 m 2 3 0 mm 1247 915 1385 1385 17 959 981 850 345 25 444 0 270 848 CPC-4 24.8 m 2 4 0 mm 1247 1169 1385 1385 1237 959 1305 850 345 25 444 0 270 995 CPC-6 37.2 m 2 6 300 mm 60 995 1553 1769 1657 1717 57 00 5 25 825 260 423 1275 CPC-8 49.6 m 2 8 300 mm 60 1169 1553 1769 1657 1717 1231 00 5 25 825 260 423 1275 CPC-12 74.4 m 2 12 0 mm 60 1728 1553 1919 17 1717 1790 00 5 25 825 260 423 1317 Publication 3021C (GB) 0211 Donaldson reserve the right to alter design without notice. Freedom from patent restrictions must not be assumed.

PowerCore dust collector with dust container (with integral fan) Suitable for inside and outside locations. (CPC-6F illustrated). 600 required for maintenance A j h n r minimum clearance for fan removal 500 required for maintenance B 500 mimimum clearance k Cleaned air outlet (positioned on left-hand side for CPC-12F) Hinged access door m p C without optional explosion relief (as illustrated) D with optional explosion relief Fan terminal box Manometer connections Controller Compressed air inlet ½" BSP Parallel (may be fitted either side) Contaminated air inlet 80 litre dust container E q F G Filtration Number Type area of filter Inlet spigot Fan DIMENSIONS in mm (Ultra-Web (inside dia.) a B C D E F G h j k m n p q r ) packs K5 CPC-3F 18.6 m 2 3 0 mm K7 SF 1247 915 28 28 17 959 981 850 312 508 444 0 993 848 650 K K7 CPC-4F 24.8 m 2 4 0 mm SF 1247 1169 2163 2163 1237 959 1305 850 312 563 444 0 48 995 700 K K 60 2331 2547 00 335 548 260 11 700 CPC-6F 37.2 m 2 6 300 mm K11 60 995 2331 2547 1657 1717 57 00 335 548 825 260 11 1275 700 K15 2180 2641 2857 12 425 733 380 1511 15 K11 60 2331 2547 00 335 548 260 11 700 CPC-8F 49.6 m 2 8 300 mm 1169 1657 1717 1231 825 1275 K15 2180 2641 2857 12 425 733 380 1511 15 K15 CPC-12F 74.4 m 2 12 0 mm 60 1728 2553 2919 17 1717 1790 00 500 7 825 260 1423 1317 10 ART 562 2

Alternative hopper and support arrangements (CPC-6 illustrated) Universal hopper Contaminated air inlet C d 1397 A Universal hopper B Type a B C d CPC-3U and CPC-3FU 959 mm 981 mm 1801 mm 1666 mm CPC-4U and CPC-4FU 959 mm 1305 mm 21 mm 1813 mm CPC-6U and CPC-6FU 1717 mm 57 mm 2442 mm 94 mm CPC-8U and CPC-8FU 1717 mm 1231 mm 2442 mm 94 mm CPC-12U and CPC-12FU 1717 mm 1790 mm 2505 mm 2136 mm Contaminated air inlet Rotary valve hopper C 380 d Rotary valve (optional) A Rotary valve hopper B Type a B C d CPC-3R and CPC-3FR 959 mm 981 mm 1801 mm 1666 mm CPC-4R and CPC-4FR 959 mm 1305 mm 21 mm 1813 mm CPC-6R and CPC-6FR 1717 mm 57 mm 2442 mm 94 mm CPC-8R and CPC-8FR 1717 mm 1231 mm 2442 mm 94 mm CPC-12R and CPC-12FR 1717 mm 1790 mm 2505 mm 2136 mm 3

Fan selection 500 Static pressure at fan inlet (mm W.G.) 450 0 350 300 250 0 150 0 50 UNIT RESISTANCE (CPC-3 K5 and CPC-4) SF K K7 K11 UNIT RESISTANCE (CPC-6 and CPC-8) UNIT RESISTANCE (CPC-12) ART 562 K15 0 00 00 3000 00 5000 6000 7000 8000 9000 Air volume (m 3 /h) Unit performance curves Estimated data These curves indicate static pressure available at fan inlet for a given volume when fitted inside a PowerCore CPC dust collector. To select the most suitable fan for a given application: 1 Determine the air volume, in m 3 /h, needed to entrain the dust. 2 Read off the unit resistance, in mm W.G., at air volume required. 3 Assess pressure drop over dust collector, prior to cleaning, usually 0 mm W.G. 4 Estimate pressure drop through connected system i.e. between point of entrainment and collector inlet. 5 The sum of 2, 3 and 4 = W.G. required. 6 Consult graph for fan performance available. Noise levels Machinery noise levels are an important consideration in the design and selection of new equipment. Several EC Directives and National Laws/Regulations adopting these directives make reference to airborne noise emissions. Actions that employers are required to comply with if employees are subjected to a daily personal noise exposure Lep,d of 80 db(a) or more are also specified. All readings were taken in normal industrial areas, i.e. semi-reverberant surroundings, with local equipment silent. Measurements were taken at maximum air flow conditions at 1.0 metre radius from the equipment housing and 1.6 metres above base level, using a precision sound level meter and octave filter. K5 K7 SF K K11 K15 ART 562 (2.2 kw) (3.0 kw) (4.0 kw) (5.5 kw) (7.5 kw) (11.0 kw) (11.0 kw) 75 db(a) 77 db(a) 75 db(a) 75 db(a) 79 db(a) 79 db(a) 79 db(a) Noise levels of installed equipment may vary due to site conditions. Estimated data. 4

Compressed air requirements Type Atmospheric Working compressed air volume F.A.D. air pressure a b at 12 s intervals c Pulse duration CPC-3 6.2 bar 90 psig 16 m 3 /h 9.4 cfm 0 ms CPC-4 6.2 bar 90 psig m 3 /h* 11.8 cfm* 0 ms CPC-6 6.2 bar 90 psig 16 m 3 /h 9.4 cfm 0 ms CPC-8 6.2 bar 90 psig m 3 /h* 11.8 cfm* 0 ms CPC-12 6.2 bar 90 psig 25 m 3 /h 14.7 cfm 0 ms a Normal operating pressure. b Recommended atmospheric air volume of clean, dry compressed air. c Recommended initial settings; these may be varied with experience. * Estimated data. Net weights Collector with dust container Type Fan type Net weight (approx.) CPC-3 3 kg CPC-3F K5 K7 SF K 563 kg 588 kg 639 kg 618 kg CPC-4 484 kg K7 690 kg CPC-4F SF 741 kg K 7 kg CPC-6 704 kg K 914 kg CPC-6F K11 974 kg K15 97 kg CPC-8 767 kg CPC-8F K11 K15 43 kg 1175 kg CPC-12 987 kg CPC-12F K15 ART 562 1443 kg 1448 kg Collector with universal hopper Type Fan type Net weight (approx.) CPC-3U 418 kg CPC-3FU K5 K7 SF K 578 kg 603 kg 654 kg 633 kg CPC-4U 500 kg K7 706 kg CPC-4FU SF 757 kg K 736 kg CPC-6U 728 kg K 937 kg CPC-6FU K11 997 kg K15 1121 kg CPC-8U 781 kg CPC-8FU K11 K15 57 kg 1189 kg CPC-12U 00 kg CPC-12FU K15 1456 kg ART 562 1461 kg All weights shown indicate heaviest configuration. Collector with rotary valve hopper Type Fan type Net weight (approx.) CPC-3R 433 kg CPC-3FR K5 K7 SF K 593 kg 618 kg 669 kg 648 kg CPC-4R 515 kg K7 721 kg CPC-4FR SF 772 kg K 751 kg CPC-6R 743 kg K 953 kg CPC-6FR K11 13 kg K15 1136 kg CPC-8R 796 kg CPC-8FR K11 K15 72 kg 14 kg CPC-12R 15 kg CPC-12FR K15 1472 kg ART 562 1477 kg 5

Foundation Details (CPC-12 illustrated) e d e f e g 4 holes 24 mm for M12 foundation bolts A 0 c g For collectors with dust container, fix base with suitable bolts (4 holes 12 mm) f e f h 646 h f B FRONT OF COLLECTOR Type a B c d e f g h CPC-3 959 mm 981 mm 819 mm 841 mm 70 mm 1 mm 169.5 mm 57.5 mm CPC-4 959 mm 1305 mm 819 mm 1165 mm 70 mm 1 mm 169.5 mm 219.5 mm CPC-6 1717 mm 57 mm 1547 mm 887 mm 85 mm 130 mm 528.5 mm 75.5 mm CPC-8 1717 mm 1231 mm 1547 mm 61 mm 85 mm 130 mm 528.5 mm 162.5 mm CPC-12 1717 mm 1790 mm 1547 mm 16 mm 85 mm 130 mm 528.5 mm 442 mm Electrical requirements IPC Controller, IPC (DR) Controller or Total Control Board (TCB): Voltage input (IPC or IPC (DR)): AC version: 5-1V, 0-2V (±%), Single Phase, 50/60Hz dc version: 24V Voltage input (TCB): 0V AC, Three Phase, 50Hz Fan motor: To suit local voltage 6

Cleaned air outlet details for collectors with fan (outlet grille removed) 3 pitches @ 115 mm 1 150 1 3 pitches 60 145 570 2 pitches 4 pitches 600 700 4 pitches 145 14 holes threaded to accept M6 set screws 325 14 holes threaded to accept M6 set screws 370 18 holes threaded to accept M6 set screws 430 60 CPC-3F and CPC-4F CPC-6F and CPC-8F CPC-6F K15, CPC-8F K15 and CPC-12F Cleaned air outlet details for collectors without fan DIN 24154/2 4 FRONT OF COLLECTOR 575 12 holes threaded to accept M bolts equally spaced on 448 mm p.c.d. 500 7

Universal hopper outlet flange details 50 4 pitches @ 130 mm 560 460 4 pitches @ 130 mm 16 holes 12 mm for M bolts 50 460 50 560 Rotary valve hopper outlet flange details 25 50 2 pitches @ 151 mm 25 352 252 2 pitches @ 151 mm 8 holes 14 mm for M12 bolts 25 50 252 50 352 Rotary valve outlet flange details (for rotary valve supplied by Donaldson) 250 395 8 holes 14 mm for M12 bolts equally spaced on 350 mm p.c.d. 8

Optional explosion relief (CPC-3, -4, -6 and -8) (showing flange mounting details) 42.5 5 pitches 42.5 254 42.5 495 3 pitches 37.5 42.5 795 Rear ELEVATION CPC-3 and CPC-4 All holes 12 mm for M bolts. If a vent duct is not connected to the explosion relief flange, then a minimum clearance of 500 mm should be made to the rear of the collector to ensure efficient operation of the explosion venting process. Consideration should be given to the local surrounding area with regards to the pressure and flame effects. 95 9 pitches 95 98 15 97.5 557.5 3 pitches 55 1500 CPC-6 and CPC-8 (Explosion relief may be fitted either side) Top and vertical flange holes mm for M8 bolts. Bottom flange holes threaded to accept M8 bolts. If a vent duct is not connected to the explosion relief flange, then a minimum clearance of 500 mm should be made to the side of the collector to ensure efficient operation of the explosion venting process. Consideration should be given to the local surrounding area with regards to the pressure and flame effects. 9

Optional explosion relief (CPC-12) (showing flange mounting details) 95 9 pitches 95 98 15 97.5 707.5 4 pitches 55 1500 CPC-12 (Explosion relief may be fitted either side) Top and vertical flange holes mm for M8 bolts. Bottom flange holes threaded to accept M8 bolts. If a vent duct is not connected to the explosion relief flange, then a minimum clearance of 500 mm should be made to the side of the collector to ensure efficient operation of the explosion venting process. Consideration should be given to the local surrounding area with regards to the pressure and flame effects. Optional weather cowl (CPC-6 illustrated) 733 22 (CPC-3 and 4) = 575 = 112 (CPC-6, 8 and 12) 225 Cleaned air outlet

Optional TCB Controller (CPC-6 illustrated) 252 TCB Controller (may be fitted either side*) * The TCB Controller must be fitted on the opposite side to the explosion panels on CPC-6, CPC-8 and CPC-12 collectors fitted with explosion relief. Design Limits (standard equipment) temperature range: - to +60 C Pressure limits: Collectors without fan: -500 mm W.G. (For positive pressures please refer to Donaldson) Collectors with fan: as fan performance curves from shut-off to operating pressure dimension tolerances: ±5 mm on main dimensions; ±2 mm on detail dimensions Paint finish: Quick air drying RAL 5019 (blue), spatter finish, semi-gloss Equipment is available suitable for use in a potentially explosive atmosphere (Directive 94/9/EC) satisfying the requirements for group II category 2G or 2D and 3G or 3D T135 C 11

www.donaldson.com Humberstone Lane Thurmaston Leicester LE4 8HP England Tel +44 (0)116 269 6161 Fax +44 (0)116 269 3028 Email: IFS-uk@donaldson.com Research Park Building No. 1303 Interleuvenlaan 1 B-3001 Leuven (Heverlee) Belgium Tel +32 (0)16 383 970 Fax +32 (0)16 383 938 Email: IFS-europe@donaldson.com