Capacitor Switching Contactors Type K3...-A, K3...-K

Similar documents
High Reliable Components for Power Factor Correction and Power Quality

High Reliable Components for Power Factor Correction and Power Quality

Latch for Contactors 4-pole see page 36. Ratings Rated Aux. Contacts Type Coil voltage 2) AC2 Current Built-in Additional 24 24V= DC 5

Micro Contactor MA Series

Contactor Catalogue. According to CE, IEC 947, EN Pole & 4 Pole Contactors 4kW - 160kW Thermal Overload

Essential equipment for all your requirements

Approved Standards. Ordering Information. Mini Contactor Relays 4-pole J7KNA-AR. Model Number Legend. Main contactor. Accessories

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Approved Standards. Motor Contactor. Main contactor. Accessoires. 21 Motor Contactor J7KN

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Contactors RAST 5 D778E131

Model Number Legend. Motor Contactor J7KN. Motor Contactor J7KN 1

Contactors Motor-Starters D677E121

Approved Standards. Ordering Information. Thermal Overload Relay J7TKN. Model Number Legend. Thermal Overload Relay. Accessories

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

D509E. Manual Motor - Starters

Contactors KNL A 68 KNL6, KNL9, KNL12, KNL16, KNL18, KNL22, KNL30. Dimensional drawing of KNL KNL6, KNL9, KNL12, KNL16, KNL18 KNL22, KNL30

Medium Voltage Capacitors

AF40... AF96 3-pole contactors Technical data

RSC09 RSC16 RSC22 RSC38 RSC43 RSC63 RSC-AUX

CI-TI Contactors and motor starters Types CI 61 - CI 98

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

ASL09..S 3-pole Contactors - Spring Terminals

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Automatic COSYS PFC. Automatic power factor correction system NEW

Technical Information

3RT14 Contactors with 3 Main Contacts

Power Factor Correction Capacitors Type LKT

General Catalogue. Quality made in D946E173

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Modular Contactors and Switches D681E121

Other Devices. Installation Contactors Z-SCH. Connection diagrams Z-SCH NO 3 NO / 1 NC. Permitted Installation Positions

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

Contactor Types CI 61-98

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

Index. Page. General 4 Approvals 5 Technical Information 9 Mounting Information 10

Power Factor Correction Capacitors in sheet steel cases

MSW. MSW Catalog Number Sequence. Standard Features MSW 25 B- 3

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

Chapter 08 Dynamic power factor correction systems (real time PFC) Dynamic power factor correction systems (real time PFC) Optimised, thermal design

FUSES. Safety through quality

TAE pole Contactors

3 - Protection components Motor circuit-breakers

LV Capacitor CLMD03 Power Module Instruction manual

Film Capacitors Power Factor Correction

Power Factor Correction

DATASHEET - DILMC9-10(24VDC) Technical data General. Contactor, 3p+1N/O, 4kW/400V/AC3. Catalog No Eaton Catalog No. XTCEC009B10TD.

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

contactor may be required to interrupt up to 200% current. The N.O. contacts are equipped with permanent magnet blowouts to meet this requirement.

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

Film Capacitors - Power Factor Correction

Series CA5 Contactors

HHD HIGH VOLTAGE FUSES GERMAN DIN STANDARD. The temperature limiting function of the fuse striker pin. Design and construction.

Technical Information

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Modular contactor for installation into distribution boards

MODVAR Low voltage reactive power compensation modules Installation manual

Description. Positive safety relays

HARMONIC FILTER REACTOR

SD Series Non-Fused Load Switches

Pre wired limit switches

AE 9... AE 40 Contactors NE... Contactor Relays

Ktec Contactors and thermal overloads

C1000 Series Automatic Cap Bank

UL & CSA Technical data A/AE9 A/AE/AF110, AL9 AL40 AC & DC operated

Series CA6 Contactors

For Info: Phone: Fax:

AF series contactors (9 2650)

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

About us. Switchgear Factory, Mumbai

multicond Power capacitors Data sheet: multicond

VB6, VB7 3-pole mini reversing contactors with screw terminals 4 to 5.5 kw AC operated

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

MAKING MODERN LIVING POSSIBLE. Technical brochure. Minicontactors CI 5-

NSL..S 4-pole / 8-pole Contactor Relays - Spring Terminals

1 3RT1016-1A**1 1 3RT1017-1A** RT1025-1A** RT1025-3A** RT1034-1A** RT1034-3A**0 175.

XMC0 Series. Definite Purpose Contactors

CI-TI Contactors and Motor Starters Type CI 6-50

Miniaturized limit switches

Installation Contactors RIC, RAC

Technical data for manual motor starters Type MS325

Application Mini Contactors for Motors and Resistive Loads

AF series contactors (9 2650)

Bulletin 825 SMM Smart Motor Manager

Modular contactors and relays

3TM Vacuum Contactors

FUJI Magnetic Contactors and Motor Starters

Motor Starting Solutions Open Type Version, in Kit Form

NEW. Heavy Duty Capacitors. Power Factor Correction Capacitors Type LKT. It s all about saving your money! Features that matter:

Power Factor Correction Equipment

max pole for t=15 ms

Components for EEx e Panels

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

Mini Contactors CI 4-

Transcription:

Type K3...-A, K3...-K Features that matter: Patented design with significant damping on inrush-current Long-life contactors tested by FRAKO up to 100,000 switching operations Suitable for unchoked and choked Power Factor Correction Systems Very high operational reliability 21

Description Capacitor contactors for unchoked power factor correction systems During the switching of unchoked power factor correction capacitors a peak-switching current of 200 times of the nominal current can occur. This load is stressing the capacitors and the switching contacts of the contactors immensely. This can lead to welded main contacts of contactors. Therefore modern power factor correction systems are currently equipped with special capacitor contactors additionally with resistance wires. The in-rush current will be damped strongly by the resistors. After approximately 5 ms the main contacts of the contactor are switching in and taking over the current supply to the capacitors. Further to this the leading contacts open up and no cur- to avoid an additional power loss. Capacitor contactors with leading transition contact and additional resistance wires offer the following advantages to power factor correction system applications: Improvement of the voltage quality during the switching process Long life of the contactors High operational reliability of the power factor correction system Extension of the maintenance periods of the power factor correction systems Suitable for choked and unchoked power factor correction systems due to leading transition contacts opening during permanent operation. Capacitor contactors for choked power factor correction systems When choked power factor correction systems are switched, the peak-switching current is essentially lower because of the high inductivity of the harmonic systems. By using special wear-resistant contact material for these applications it is possible to use capacitor contactors without series resistors. These special capacitor contactors offer the following advantages for choked power factor correction systems: Safe switching on and off of choked capacitor steps Improved voltage quality through chatter-proofed switching operations Long-life of the contactors (> 100,000 switching operations) High operational reliability of the power factor correction system 22

Rated operational power at / Hz Aux. contacts Type Article-No. Weight Ambient temperature: built-in add. C C Coil voltage 380 V 415 V 6 V 380 V 415 V 6 V 220 240V Hz 400 V 440 V 690 V 400 V 440 V 690 V kvar kvar kvar kvar kvar kvar NO NC pcs. kg/pc. 0-12.5 0-13 0-20 0-12.5 0-13 0-20 1 1 K3-18K10 230 89-00280 0.34 10-20 10.5-22 17-33 10-20 10.5-22 17-33 3 K3-24K00 230 89-00279 0.62 10-25 10.5-27 17-41 10-25 10.5-27 17-41 3 K3-32K00 230 89-00278 0.62 20-33.3 23-36 36-55 20-33.3 23-36 36-55 3 K3-K00 230 89-00277 1.0 20-23-53 36-82 20-23-53 36-82 3 K3-62K00 230 89-00276 1.0 20-75 3) 23-75 3) 36-120 3) 20-23-64 36-100 3 K3-K00 230 89-00286 1.0 33-80 36-82 57-120 33-75 36-77 57-120 6 4) K3-90K00230 89-00356 2.3 33-100 5) 36-103 5) 57-148 5) 33-90 5) 36-93 5) 57-148 5) 6 4) K3-115K00230 89-00357 2.3 1HN.. or HA.. snap-on 2HB.. for side mounting and 1HN.. or HA.. snap-on 3) Consider the max. thermal current of the contactor K3- A: 4) 2HB.. on the left or right side and 4 HN.. or HA.. snap-on 5) Consider the min. cross-section of conductor at max. load I th 130 A e. Operating Conditions: Capacitor switching contactors are protected against contact welding for a prospective making current of 200 x l e. acc. to IEC 947-4-1, IEC 947-5-1, EN 947-4-1, EN 947-5-1, VDE 06 Type K3-18K K3-24K K3-32K K3-K K3-62K K3-K K3-90K K3-115K Max. frequency of operations z 1/h 120 120 120 120 120 80 80 80 Contact life: unchoked capacitor banks S x 10 3 2 1 1 1 1 120 100 75 Contact life: choked banks S x 10 3 400 300 300 300 300 200 200 200 at C A 0-18 14-28 14-36 30-48 30-72 30-108 -115-144 at C A 0-18 14-28 14-36 30-48 30-72 30-87 -108-130 Fuses gl (gg) from/to A 35/63 /80 63/100 80/1 125/1 1/200 1/200 1/2 L1 L2 L3 Mounting Instructions Typical Circuit Diagram A1 A2 1 2 3 4 5 6 used only, because abnormal temperatures within the area of the resistor spirals cannot be excluded. Auxiliary Contact Blocks Rated operational current Contacts Type Article-No. Weight AC15 AC1 230 V 400 V 690 V A A A For contactors NO NC kg/pc. 3 2 10 K3-24 to K3-115 1 1 HB11 89-00294 0.02 for side mounting 3 2 10 K3-18 to K3-115 1 HN10 89-00281 0.02 23

Rated operational power at / Hz Aux. contacts Type Article-No. Weight Ambient temperature: built-in add. C C Coil voltage 380 V 415 V 6 V 380 V 415 V 6 V 220 240 V Hz 400 V 440 V 690 V 400 V 440 V 690 V _ kg/pc. kvar kvar kvar kvar kvar kvar NO NC pcs. 12.5 13 20 12.5 13 20 1 4 K3-18A10 230 89-00288 0.23 20 22 33 20 22 33 6 K3-24A00 230 89-00289 0.48 25 27 41 25 27 41 6 K3-32A00 230 89-00290 0.48 33.3 36 55 33.3 36 55 6 K3-A00 230 89-00291 0.85 53 82 53 82 6 K3-62A00 230 89-00292 0.85 75 3) 75 3) 100 64 100 6 K3-A00 230 89-00293 0.85 80 82 120 75 77 120 9 4) K3-90A00 230 89-00358 2.2 100 5) 103 5) 148 5) 90 5 ) 93 5) 148 5) 9 4) K3-115A00 230 89-00359 2.2 4HN.. or HA.. snap-on 2HB11 on the left or right side and 4HN.. or HA.. snap-on 3) Consider the max. thermal current: I 130 A 4) 2HB.. on the left or right side and 7 HN.. or HA.. snap-on 5) Consider the min. cross-section of conductor at max. load th L1 L2 L3 Mounting Instructions Typical Circuit Diagram A1 A2 1 2 3 4 5 6 used only, because abnormal temperatures within the area of the resistor spirals cannot be excluded. Dimensions Capacitor switching contactors, AC-operated K3-18K... 98 35-36 94 Contactors, AC-operated K3-18A10 35-36 65.5 61.5 59 49- ø5 M3.5 85 59 49- ø5 M3.5 K3-24K00 K3-32K00 35 119.5 115.5 K3-24A00 K3-32A00 35 87.5 83.5 ø4.5 ø4.5 65 65 M5 115 M5 24 63 63

Dimensions Capacitor switching contactors, AC-operated K3-K00 K3-62K00 K3-K00 128.5 124.5 Contactors, AC-operated K3-A00 K3-62A00 K3-A00 96 92 ø5.5 ø5.5 110 100 95 1 110 100 95 M6 M6 7.5 68 7.5 68 K3-90K00 K3-115K00 90 152.5 75 120 115 K3-90A00 K3-115A00 90 75 120 115 155 137 70 155 137 70 M8 M8 31.5 31.5 9 31.5 31.5 9 Main Contacts Type K3-18K K3-24K K3-32K K3-K K3-62K K3-K K3-90K K3-115K Switching of three-phase current pfc-systems 690 V A 0 18 14 28 14 36 30 48 30 72 30 108 115 144 Rated operational power 220 240V kvar 0 7 5 11 5 14 12 20 12 28 12 33 20 20 55 380 400 V kvar 0 12.5 10 20 10 25 20 33.3 20 20 75 33 80 33 100 415 440 V kvar 0 13 10.5 22 10.5 27 23 36 23 53 23 75 36 82 36 103 0 V kvar 0 15 12 25 12 30 26 40 26 26 75 43 100 43 120 525 V kvar 0 15 12 25 12 32 26 43 26 64 26 80 105 125 6 690 V kvar 0 20 17 33 17 41 36 55 36 82 36 120 57 120 57 148 1000 V kvar 85 1 85 200 690 V A 0 18 14 28 14 36 30 48 30 72 30 87 108 130 Rated operational power 220 240 V kvar 0 7 5 11 5 14 12 20 12 28 12 30 20 40 20 380 400 V kvar 0 12.5 10 20 10 25 20 33.3 20 20 33 75 33 90 415 440 V kvar 0 13 10.5 22 10.5 27 23 36 23 53 23 64 36 77 36 93 0 V kvar 0 15 12 25 12 30 26 40 26 26 70 43 90 43 110 525 V kvar 0 15 12 25 12 32 26 43 26 64 26 75 95 115 6 690 V kvar 0 20 17 33 17 41 36 55 36 82 36 100 57 120 57 148 1000 V kvar 85 1 85 180 Consider the max. thermal current: I th 130 A Consider the min. cross-section of conductor at max. load 25

Data according to IEC 947-4-1, EN 947-4-1, VDE 06 Main Contacts Type K3-18A K3-24A K3-32A K3-A K3-62A K3-A K3-90A K3-115A Switching of three-phase current pfc-systems 690 V A 18 28 36 48 72 108 115 144 Rated operational power 220 240V kvar 7 11 14 20 28 33 55 380 400 V kvar 12.5 20 25 33.3 75 80 100 415 440 V kvar 13 22 27 36 53 75 82 103 0 V kvar 15 25 30 40 75 100 120 525 V kvar 15 25 32 43 64 80 105 125 6 690 V kvar 20 33 41 55 82 120 120 148 1000 V kvar 1 200 690 V A 18 28 36 48 72 87 108 130 Rated operational power 220 240 V kvar 7 11 14 20 28 30 40 380 400 V kvar 12.5 20 25 33.3 75 90 415 440 V kvar 13 22 27 36 53 64 77 93 0 V kvar 15 25 30 40 70 90 110 525 V kvar 15 25 32 43 64 75 95 115 6 690 V kvar 20 33 41 55 82 100 120 148 1000 V kvar 1 180 Consider the max. thermal current: I th 130 A Consider the min. cross-section of conductor at max. load Main Contacts Type K3-18 K3-24 K3-32 K3- K3-62 K3- K3-90 K3-115 Maximum ambient temperature Operation open C 40 to + (+90) enclosed C 40 to +40 Storage C to +90 Short circuit protection for contactors without thermal overload relay Coordination-type 1 according to IEC 947-4-1 Contact welding without Hazard of persons Max. fuse size gl (gg) A 100 100 100 1 1 1 200 2 Mechanical life AC-operated S x 10 6 10 10 10 10 10 10 5 5 DC-operated S x 10 6 10 10 10 10 10 10 5 5 Short time current 10s-current A 144 184 240 3 4 592 680 880 Power loss per pole At l e /AC3 400 V W 0.5 0.7 1.3 2.2 3.9 5.5 4.3 6.0 With reduced control voltage range 0.9 up to 1.0 x U s and with reduced rated current I e /AC1 according to I e /AC3 26