Connect - Contact - Control. Connectors. High Power Connectors for industrial trucks Catalogue A84.en

Similar documents
Connectors. LV Series High Power Connectors for faster charging of industrial trucks Catalogue A84.en. more information here: schaltbau-gmbh.

Connect - Contact -Control. Charging Connectors LV Series A84.en

S840, S845, S846 Series Single-break changeover, NC or NO contacts, positive opening operation and wiping action Catalogue D40.en

Contactors. CL1115/02, CL1215/02, CL1315/02 1, 2 and 3 pole AC and DC NO contactors for voltages up to 1,500 V Catalogue C25.en

S826, S926 Series Dual changeover switches with positive opening operation and wiping contacts Catalogue D26.en

Contactors. C110B/80, C110B/120 C110B/200, C110B/300 Single pole DC NO contactors for industrial trucks Catalogue B71.en

Series S847 Changeover switches featuring wiping, galvanically isolated, double-break contacts and positive opening operation Catalogue D47.

Contactors. CH1130/02 Series Single pole high-voltage contactor up to 3 kv Catalogue C170.en. Connect - Contact - Control

Connectors. M Series Circular Modular Connectors Catalogue A10.en

Connnectors. B Series Connectors for rail vehicles Catalogue F160.en. More information here: schaltbau-gmbh.com

Connect - Contact - Control. Brochure. l Connectors

SD, SE, SDE, SCO series Multipole switchgear for rail vehicles: Disconnecting switches, Earthing Switches, Disconnector with Earthing Switches,

Brochure Connectors. More information here: schaltbau-gmbh.com

Play it safe Connectors Switches Contactors. Material Handling. Improved performance for rapid charging

S870, S970 Series. Snap-action switches. Positive opening operation Self-cleaning contacts Catalogue D70.en

Connect - Contact - Control. Connectors. Series Circular Modular. Connectors. Manual A10-M.en

Contactors. CT1115/04, CT1130/04 CT1215/04, CT1230/04 CT1315/04, CT1330/04 1, 2 and 3 pole power contactors for AC and DC Catalogue C20.

SCHALTBAU CONNECTIONS ALL FROM ONE SOURCE

l Snap-Action Switches

l Snap-Action Switches

Connect - Contact - Control. Fuses for high-voltage switchgear F-HS, F-VS Series Ø 60. F 185.en

Play it safe Connectors Switches Contactors. New Energy. Special Switchgear Solutions

S880 Series Snap-action switches with positive opening operation and self-cleaning contacts Catalogue D80.en

Contactors. Brochure. Contactors for industry, rolling stock and battery-powered vehicles Emergency disconnect switches

Connect - Contact - Control. Circular Audio Miniature Connectors Series NF07 Series NF10 12,5 Ø max. max. cable diameter.

REMA TECHNICAL INFORMATION DIN 80, 160, 320. Page 1 of 13

Installation Instructions (Translation) Marking. Description. Danger, warning and note symbols. Technical data. ANTARES ExtSet.

Han K 3/0, K 3/2 / Han HC Modular. Contents Technical characteristics Han K 3/0, Han K 3/ Inserts Han K 3/0, Han K 3/

Installation and operating instructions. Solar charge controller MPPT 10 A / 20 A Z Z

7000 Series Buccaneer

Directory chapter 08. InduCom Robust and EMI protected D-Sub interfaces

Electronic Circuit Breaker ESS20-0..

Connectors. ZH Series Inter-car jumpers to UIC 552 Installation and Maintenance Instructions Manual F122-m.en

X-COM - and X-COM S-SYSTEM Pluggable Rail-Mounted Terminal Blocks

Operating Instructions

General characteristics and technical data Series MCS

CrossBoard. The new basic system

Viking 3 - Screw connection Disconnect terminal blocks

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

ALFRA Akku-Compact Flex Handstanze Art.-Nr / Prod.-No / N art / Nº de prod

Switches Unlimited Phone: * Fax:

7000 Series Buccaneer

Electronic Circuit Breaker ESS20

MINI MCR-SL-UI-UI(-SP)(-NC)

Operating instructions Solenoid interlock TKM/TKF. 1. About this document. Content

HIGH POWER CONNECTORS MOLDED REMA CONNECTOR (MRC) 320

Datasheet. System pitch mm (0.400 inch) - SU/BU BUZ 10.16HP/02/180F AG BK BX

Data sheet E-DAT Industry RJ45 field plug black Cat.6 Class E A

POWER TRIPLE LOCK* Connector System

Europe Series Connectors

Connect - Contact - Control. Charging Connectors LV Series A 84.en

6000 Series Buccaneer. Secure, quick connector mating and release. 30 twist locking Tamperproof lock prevents accidental un-mating

REMA BATTERY CONNECTOR DIN320

Type Operating Instructions. Bedienungsanleitung Manuel d utilisation. 2/2-Way Solenoid Valve 2/2-Wege-Magnetventil Électrovanne à 2/2 voies

Han Q 1/0 Axial Screw Protected. Available February 2017

Cam-Lok Single Pole Connectors

Safety instructions. Always... Never... Fire hazard! Dear customer,

Distribution Blocks & Bus-bar Solutions

Technical Data Sheet VENUS FLA SCM

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

Powerline QC. Single Power Connectors. Ten 47 Limited

AMPLIMITE* HDP- 20 and Economy

UTS In-line receptacle

Cam-Lok Single Pole Connectivity. The industry standard for reliable service under the most severe operating conditions.

Data sheet C6 A RJ45 field plug pro

TRANSPORTATION TECHNOLOGY. Customizing is Our Standard

INSTRUCTION MANUAL. Maintenance-free Absorbent Glass Mat technology and valve-regulated batteries. (AGM / VRLA)

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 high voltage contacts Quick and easy assembling Protection class IP68 acc.

Page 2-4 Page 2-8. Page Page 2-13

REMA BATTERY CONNECTOR DIN 80

Industrial plug-in connectors HEAVYCON EVO. efficient at a twist of the wrist

Technical Data, High Power 2-way* Cannon APD / ISO Connectors. Electrical Data. Mechanical Data. Environmental Data (acc.

Single pole connectors

Modular Bayonet connectors: a flexible solution for data and signals transmission in railways harsh environment.

Contents Technical characteristics Han A Technical characteristics Han 3 A with HARAX Termination

8WH6 ipo Plug-In Terminals

IEC TERMINAL BLOCKS. Screw Clamp Connection. Feed Through DIN Rail 433. Ground DIN Rail 439. Fuse Holder DIN Rail 445. Disconnect DIN Rail 448

General characteristics

Power distribution components

Powerline. Single Power Connectors. Ten 47 Limited

OBE, OBEXU, ON BOARD Battery Chargers

FISCHER ULTIMATE TM SERIES RUGGED COMPACT LIGHTWEIGHT KEY FEATURES

Industrial Switchgear New Products Catalogue Pole Switching with the DILMP Contactors

Engineered installation products Solutions for control panel applications

DX³ RCCBs - ID 4P up to 100 A

Operating voltage up to 5 kvdc Operating current up to 4,5 A 2-6 High voltage contacts Quick and easy assembling Protection class IP68 acc.

Data sheet... OMNIMATE Signal - series LM LM 5.00/04/90 3.5SN OR BX

Selection Guide Motor Control Device Solutions

Reliable Protection. Simplified Wiring. CI-K enclosure system

Short-circuit current limiter S800-SCL-SR

Battery Chargers Sealed or Valve Regulated Lead Acid Batteries Models: PSC A AND PSC A

8WH2 Spring-Loaded Terminals

Add-on blocks and accessories For BG series mini-contactors For BF series contactors For B series contactors...

Manual Motor Starters. Meta-MEC

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Amphenol. eries SJT. Series SJT. VG 96912, Series 1 PAN JN 1003

For air dampers and control valves of oil or gas burners

Installation manual wall-mounted distributor

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

SECTION SECTION. EATON 2014 Arrow Hart Buyers Guide

Transcription:

Connect - Contact - Control 1 LV-HPC Connectors Series High Power Connectors for industrial trucks Catalogue A84.en

High Power Connectors LV-HPC Series More Power for Faster Charging With the new LV-HPC Series Schaltbau charging connectors satisfy the requirements of DIN VDE 063-589 for a high current-carrying capacity. Thus an active energy and battery management system that optimises the current flows and preserves the battery becomes possible. After use, the batteries can be quickly recharged so as to minimize downtimes. Due to its modular design, the charging connector can be adapted to customer requirements. Additional pilot contacts are available for use with battery management systems, which constantly monitor the condition of the (li-ion) battery, thereby guaranteeing maximum battery life. Charging connectors must keep to the maximum temperature difference that is allowed to occur due to the charging process. The contact system of the LV-HPC Series is designed in such a way that the contacts are capable of carrying high currents with minimal self-heating. In addition to pilot contacts, optional adapters for water top up and electrolyte circulation systems are available. For details refer to catalogue A841 "Multifunctional Adapters for Charging Connectors" or visit our website at www.schaltbau-gmbh.com Features NEW! NEW! Battery receptacle High Power Battery receptacle Battery receptacle Dry-cell»T«Example: Cross section of mated connectors with 4 V keying NEW! NEW! High Power Charging plug Charging plug Vehicle plug Universal»U«Charging plug Dry-cell»T«Schaltbau Power Bridge Keying according to DIN VDE 063 589 for wet-cell and dry-cell batteries Higher current-carrying capacity The new LV-HPC charging connectors comply with DIN VDE 063 589 for a higher current-carrying capacity. High-quality, screw-machine power contacts Due to an improved design, the contacts feature a higher currentcarrying capacity, minimum contact heating and a continuous low conctact resistance. With constant contact force over its working life, the connector is less susceptible to wear and tear while mating and unmating. Modular design Standardized individual components can be used across the entire connector series. They allow for a customized and cost-effective realisation of your applications, and avoid unnecessary stocking of items. The mated shells of the LV-HPC Series connectors provide positive locking resistance to shock, vibration and other decoupling forces that may occur under normal conditions of use. Intermateable with connectors of other manufacturers The LV-HPC Series is intermateable with all commercially available charging connectors to DIN VDE 063-589 of comparable design - even when used with air tube adapter. Keying to DIN VDE 063-589 Colour coded keying plugs are used for keying of conventional battery voltages. The colours stand for: Red: Wet-cell battery, allowing for higher amparage Grey: Wet-cell battery Green: Dry-cell battery Yellow: Vehicle plug, universal The diagram shows a cross section of mated LV-HPC Series charging connectors keyed to 4 V. High resistance to acids and extremes of temperature The material used for the connector shells including strain relief is made of a thermoplastic that is highly resistant to sulphuric acid of high concentration. Exceeding the usual range of -5 C to +90 C, the proven housing material makes for the connector s ruggedness and suitability for use with temperatures ranging from -40 C to +110 C. Optional adapters for electrolyte circulation and pilot contacts : Schaltbau LV-HPC series charging connectors can be equipped with optional air tube adapters for use with batteries with electrolyte circulation system. Pilot contact adapter: To be fitted with optional pilot contacts which provide a datal link between the battery management system and the charger. For detailed information on adapter options refer to:

3 Specifications Series Standard LV 30/400 LV160/50 LV80/10 Rated operating current * 1 Main contacts Pilot contacts DIN VDE 063-589 30 A / 400 A* 1 0 A 160 A / 50 A* 1 0 A 80 A / 160 A* 1 0 A Rated voltage DIN VDE 063-589 150 V 150 V 150 V Keying Rated operating voltage Keying plug DIN VDE 063-589 4 / 36 / 48 / 7 / 80 / red* 1 / grey: wet-celll battery, green: dry-cell battery, yellow: vehicle plug Main contacts Number of Contact diameter Wire gauge AWG 5 (16 mm²) AWG 3 (5 mm²) AWG 1 (35 mm²) AWG 1/0 (50 mm²) AWG 3/0 (70 mm²) AWG 4/0 (95 mm²) DIN VDE 063-589 10 mm + LV RH 50/35* * 1 8.5 mm + LV RH 50/5* + LV RH 50/35* * 1 6 mm + LV RH 5/16* * 1 Pilot contacts Number of Contact diameter Wire gauge AWG 13 (.5 mm²) DIN VDE 063-589 4 mm 4 mm.3 mm Auxiliary contacts Number of Contact diameter Wire gauge AWG 13 (.5 mm²) DIN VDE 063-589 4 mm 4 mm.3 mm Adapter for air tube size 6 mm 9...10 mm DIN VDE 063-589 * 6 * 6 * 6 Crimped connection Main contacts Pilot contacts w/ crimping* 3 crimping w/ crimping* 3 crimping w/ crimping* 3 crimping Ingress protection rating (IP code) IEC 6059 IP3* 4 IP3* 4 IP3* 4 Temperature range -40 C... +110 C* 5-40 C... +110 C* 5-40 C... +110 C* 5 Mating cycles DIN VDE 063-589 > 5,000 > 5,000 > 5,000 Shells PBT GF30 (PBB and PBDE free) Strain relief Flammability rating UL 94-V0 UL 94-V0 UL 94-V0 Handle styles Snap-on Screw-on Handle colour Black Red (for emergency cutout) Approvals C US C US C US See Page 6, 7 Page 8, 9 Page 10, 11 * 1 For 400 A, 50 A and 10 A use corresponding red keying plug and observe the wire gauges as indicated by the DIN VDE 063-589 standard. See also page 14 for detailed information on maximum current carrying capacity of cables depending on wire gauge, and battery pulse charging. * Reducers: Included with contacts whose terminals are designed for a bigger AWG wire size reducing it down to a smaller size. * 3 Assembly and crimping instructions, will be provided on request * 4 IPx3 when mounted horizontally * 5 Observe current-carrying capacity curves, refer to page 7 (LV30/400), page 9 (LV160/50) and page 11 (LV80/10) respectively * 6 For air tubes with large inside diameters use extra adapter, see page 9: Extra air tube adapters.

4 Components, spare parts 16 3 4 5 15a 15b 1 10b 5 6 8 10a 11 13 4 3 14 15c 9 7 4 3 1a 1b Item 1a 1b Identification Plug shell Receptacle shell LV30/400 LV160/50 LV80/10 LV30/400 G-P LV30/400 G-SP LV30/400 G-SL LV160/50 G-P LV160/50 G-SP LV160/50 G-SL LV80/10 G-P LV80/10 G-SP LV80/10 G-SL Slider LV30 S LV160 S LV80 S Description Shell to enclose pin contacts Receptacle with pre-assembled item 10a Receptacle with added item 15a Locks main contacts in place (LV30 also auxiliary contacts) 3 Clamp LV30 D LV160 D LV80 D x for strain relief 4 Screw for clamp SC 3.5x19 SC 3.5x5 5 Keying plug 6 7 Main contact (socket) Main contact (pin) Reducer 8 9 10a 10b 11 1 13 14 15a 15b 15c Aux. contacts Pilot contact adapter Pilot contacts Pilot contact set Spacer Extra air tube adapter 16 Handle red red grey green yellow AWG 4/0 (95 mm²) AWG 3/0 (70 mm²) AWG 1/0 (50 mm²) AWG 3 (5 mm²) AWG 4/0 (95 mm²) AWG 3/0 (70 mm²) AWG 1/0 (50 mm²) AWG 3 (5 mm²) 70/50 (AWG 3/0 to 1/0) 50/35 (AWG 1/0 to 1) 50/5 (AWG 1/0 to 3) 5/16 (AWG 3 to 5) Socket AWG 13 (.5 mm²) Pin AWG 13 (.5 mm²) Receptacle Plug Socket AWG 13 (.5 mm²) Pin AWG 13 (.5 mm²) Adapter + socket contacts Adapter + pin contacts for receptacle for receptacle for plug Black, snap-on Red, snap-on Black, screw-on Red, screw-on LV30 S10/95 LV30 S10/70 LV30 S10/50 LV30 P10/95 LV30 P10/70 LV30 P10/50 LV RH70/50 LV RH50/35 LV30 BCC-.5-Ag LV30 SCC-.5-Ag LV50/400 NrS LV50/400 NrP LV160/30 Ngr LV160/30 Tgn LV160/30 Uge LV160/30 PA-S LV160/30 PA-P BCC-.5-Ag SCC-.5-Ag LV160/30 P-S/S LV160/30 P-P/S LV160/30 LV-S LV160/30 DS-L SC 3.5x19 LV160/50 S8.5/50 LV160 P8.5/50 LV RH50/35 LV RH50/5 LV160 BBC-.5-Ag LV160 SBC-.5-Ag LV160/30 LV-P LV80/160/30 V-S 6/6 LV80/160/30 V-S 6/10 LV160/30 H3 LV160/30 H4 LV160/30 H1/S LV160/30 H/S SC 3.5x16 LV10 NrS LV10 NrP LV80 Ngr LV80 Tgn LV80 Uge LV80/10 S6/5 LV80 P6/5 LV RH5/16 LV80 BBC-.5-Ag LV80 SBC-.5-Ag LV80 PA-S LV80 PA-P LV80 BBC-.5-Ag LV80 SBC-.5-Ag LV80 P-S/S LV80 P-P/S LV80 LV-S LV80 DS-L LV80 LV-P LV80 H1 LV80 H LV80 H1/S LV80 H/S x self-tapping screw for strain relief: Wire gauge AWG 1/0 max. (50 mm²) Wire gauge AWG 3/0, AWG 4/0 (75/90 mm²) for battery receptacle, high amparage, wet-cell for charging plug, high amparage, wet-cell for battery receptacle/charging plug, wet-cell for battery receptacle/charging plug, dry-cell for vehicle plug x main contact for battery receptacle x main contact for charging plug/vehicle plug Reducing AWG 3/0 down to AWG 1/0 Reducing AWG 1/0 down to AWG 1 Reducing AWG 1/0 down to AWG 3 Reducing AWG 3 down to AWG 5 x auxiliary contact for battery receptacle x aux. contact for charging plug/vehicle plug Adapter for pilot contacts, sockets Adapter for pilot contacts, pins x pilot contact for battery receptacle x pilot contact for charging plug/vehicle plug Set, including items 10a, 11 Set, including items 10b, 1 for air tube with inside Ø 6 mm for securing air tube adapter (item 15a) in receptacle shell (item 1b) for air tube with inside Ø 6 mm for air tube with inside Ø 6 mm for air tube with inside Ø 9...10 mm for receptacle / plug shell for receptacle/ plug shell, including screws

5, pre-assembled cables LV-HPC Series Series LV30/400 LV160/50 LV80/10 Keying plug R N T U Example: Amparage Standard High 30 A 400 A * 1 160 A 50 A * 1 80 A 10 A * 1 Red, wet-cell, high amparage Grey, wet-cell battery Green, dry-cell battery Yellow, vehicle plug, Universal * Contacts, wire gauge LV30/400 P95 Pin AWG 4/0 (95 mm²) P70 Pin AWG 3/0 (70 mm²) P50 Pin AWG 1/0 (50 mm² * 3 ) S95 Socket AWG 4/0 (95 mm²) S70 Socket AWG 3/0 (70 mm²) S50 Socket AWG 1/0 (50 mm² * 3 ) LV160/50 P50 Pin AWG 1/0 (50 mm²) P35 Pin AWG 1 (35 mm² * 3 ) P5 Pin AWG 3 (5 mm² * 3 ) S50 Socket AWG 1/0 (50 mm²) S35 Socket AWG 1 (35 mm² * 3 ) S5 Socket AWG 3 (5 mm² * 3 ) LV80/10 P5 Pin AWG 3 (5 mm²) P16 Pin AWG 5 (16 mm² * 3 ) S5 Socket AWG 3 (5 mm²) S16 Socket AWG 5 (16 mm² * 3 ) LV30/400-R-S95-0--L0-H3 None Black, snap on * 5 Red, snap on * 5 Black, screw on * 6 Red, screw on * 6 Black, snap on * 6 Red, snap on * 6 None * 4 None aux. contacts Handle H0 H1 H H1/S H/S H3 H4 L0 L1 Aux. contacts 0 Pilot contacts None 0 pilot contacts * 4 *1 Higher current-carrying capacity in compliance with DIN VDE 063 589; requires red keying plug R. * Yellow keying plug only supplied with charging and vehicle plug. *3 Contact supplied with reducer. *4 Schaltbau LV-HPC charging connectors can be equipped with optional pilot contacts or air tube adapters for electrolyte circulation systems. Do you need other optional components? You will find more information in our catalogue A841 "Multifunctional adapters for LV-HPC Series charging connectors". *5 Only available for LV80/10 Series *6 For use with LV160/50 and LV30/400 Series Schaltbau Power Bridge Modular design for scalable solutions between vehicle, battery and charger. The LV- HPC Series connectors guarantee a currentcarrying capacity of 400 A. Shell Handle Slider Main contacts Aux. contacts Adapter for * 4 pilot contacts or air tube Keying plug LV-HPC: Charging plug/vehicle plug, front view Do you need assembled connectors? Pre-assembled cables If so, do not hesitate to contact us! We supply receptacles and plugs complete with preassembled cables of different lengths and wire gauges and with a variety of cable terminal ends Cables and terminal ends: Welding cables with rubber jackets according to DIN VDE 08-6, e.g. H01N-D Flex battery terminal conductor Perfect battery terminal conductor Battery terminal conductor with cable lug Wire gauges: AWG 5... 4/0 (16... 95mm²) Wire connection: Main contacts: w/ crimping Pilot/aux. contacts: crimping Marking of cables: Red shrink tube - terminal Blue shrink tube - terminal Product named on rubber jacket of cable for the the battery to suit your requirements. Schaltbau guarantees a constant high quality of the pre-assembled connector. Strain relief: All cables are secured against stress and strain by the strain relief clamp being an integral component of the connector shell. : For air tube with inside diameter Ø 6 mm, wall thickness 1.5 mm, Shore 73 hardness. Quality assurance: DIN EN ISO 9001:000 EN ISO 14001:1996 Minimum ordering quantities: A minimum quantity of 50 applies for orders directly fom Schaltbau. For orders below that minumum quantity we recommend an authorized manufacturing sales partner in your vicinity. Schaltbau supplies connectors complete with pre-assembled battery terminal conductors to suit your application. Flex battery terminal conductor Perfect battery terminal conductor Note: Presented in this catalogue are only stock items which can be supplied in short delivery time. For some variants minimum quantities apply. Please do not hesitate to ask for the conditions. Special Varianten: If you need a special variant, please do not hesitate to contact us. Maybe the type of charging connector you are looking for is among our many special designs. If not, we can also supply customized designs. In this case, however, minimum ordering quantities apply. Battery terminal condoctor with cable lug

6 LV30/400 Series Dimension diagrams, Contacts Charging plug / vehicle plug LV30/400 41.6 83 69 IP3 150 V DC 30/400 A Ø6.65 IP3 150 V DC 30/400 A 6.1 9.5 IP3 150 V DC 30/400 A 110 67.7 53.5 4 16 181.5 186.5 Strain relief (clamp) LV160/30 H3, black [ ] LV160/30 H4, red [ ] LV160/30 H1/S, black [ ] LV160/30 H/S, red [ ] Battery receptacle LV30/400 41.7 83 69 IP3 150 V DC 30/400 A Ø6.65 IP3 150 V DC 30/400 A 94 6. IP3 150 V DC 30/400 A 67.8 110 54 4 17 176 181 Strain relief (clamp) LV160/30 H3, black [ ] LV160/30 H4, red [ ] LV160/30 H1/S, black [ ] LV160/30 H/S, red [ ] Main contacts, aux. contacts Main contacts Type Wire gauge Rated current HPC* Standard HPC* Standard Aux. contacts Type Wire gauge Rated current LV30 S10/95 Socket AWG 4/0 (95 mm²) AWG 4/0 (95 mm²) 400 A 30 A LV30 BCC-.5-Ag Socket AWG 13 (.5 mm²) 0 A LV30 P10/95 Pin AWG 4/0 (95 mm²) AWG 4/0 (95 mm²) 400 A 30 A LV30 SCC-.5-Ag Pin AWG 13 (.5 mm²) 0 A * High Power Connector, to be used with red keying plug Note: Wire gauge: Reducers also reduce the current rating. High Power Connectors: Connectors with high current-carrying capacity require a wire gauge of AWG 4/0 (95 mm²). The use of reducers is not allowed. Maximum current-carrying capacity curves: Determined solely by the wire gauge the use of reducers has no bearing on the maximum currentcarrying capacity curve. The values are only valid for the main contacts with w/ crimping. Reduced scale diagrams / dimensions in mm

7 LV160/50 Series Dimension diagrams, Contacts Charigng plug / vehicle plug LV160/50 34 83 69 Ø6.65 IP3 150 V DC IP3 150 V DC 160/50 A 160/50 A 94 54.6 IP3 150 V DC 160/50 A 110 60. 48 4 11 170 175 Strain relief (clamp) LV160/30 H3, black [ ] LV160/30 H4, red [ ] LV160/30 H1/S, black [ ] LV160/30 H/S, red [ ] Battery receptacle LV160/50 30.6 83 69 IP3 150 V DC 160/50 A Ø6.65 IP3 150 V DC 160/50 A 94 54.7 IP3 150 V DC 160/50 A 110 60. 54 4 17 176 180 Strain relief (clamp) LV160/30 H3, black [ ] LV160/30 H4, red [ ] LV160/30 H1/S, black [ ] LV160/30 H/S, red [ ] Main contacts, aux. contacts Main contacts Type Wire gauge Rated current HPC* Standard HPC* Standard Aux. contacts Type Wire gauge Rated current LV160/50 S8.5/50 Socket AWG 1/0 (50 mm²) AWG 1/0 (50 mm²) 50 A 160 A LV160 BCC-.5-Ag Socket AWG 13 (.5 mm²) 0 A LV160 P8.5/50 Pin AWG 1/0 (50 mm²) AWG 1/0 (50 mm²) 50 A 160 A LV160 SCC-.5-Ag Pin AWG 13 (.5 mm²) 0 A * High Power Connector, to be used with red keying plug Reduced scale diagrams / dimensions in mm Note: Wire gauge: Reducers also reduce the current rating. High Power Connectors: Connectors with high current-carrying capacity require a wire gauge of AWG 1/0 (50 mm²). The use of reducers is not allowed. Maximum current-carrying capacity curves: Determined solely by the wire gauge the use of reducers has no bearing on the maximum currentcarrying capacity curve. The values are only valid for the main contacts with w/ crimping.

8 LV80/10 Series Dimension diagrams, Contacts Charging plug / vehicle plug LV80/10 6 69 56 IP3 150 V 80/10 A DC Ø6.4 78. IP3 150 V 80/10 A DC 95.9 40 IP3 150 V 80/10 A DC 100 35.5 30.3 74. 18 17 Strain relief (clamp) LV80 H1, black [ ] LV80 H, red [ ] LV80 H1/S, black [ ] LV80 H/S, red [ ] Battery receptacle LV80/10 3.1 69 56 IP3 150 V 80/10 A DC Ø6.4 78. IP3 150 V 80/10 A DC 96 40 IP3 150 V 80/10 A DC 100 35.5 30.3 74. 18 17 Strain relief (clamp) LV80 H1, black [ ] LV80 H, red [ ] LV80 H1/S, black [ ] LV80 H/S, red [ ] Main contacts, aux. contacts Main contacts Type Wire gauge Rated current HPC* Standard HPC* Standard Aux. contacts Type Wire gauge Rated current LV80/10 S6/5 Socket AWG 3 (5 mm²) AWG 3 (5 mm²) 10 A 80 A LV80 BCC-.5-Ag Socket AWG 13 (.5 mm²) 0 A LV80 P6/5 Pin AWG 3 (5 mm²) AWG 3 (5 mm²) 10 A 80 A LV80 SCC-.5-Ag Pin AWG 13 (.5 mm²) 0 A * High Power Connector, to be used with red keying plug Note: Wire gauge: Reducers also reduce the current rating. High Power Connectors: Connectors with high current-carrying capacity require a wire gauge of AWG 3 (5 mm²). The use of reducers is not allowed. Maximum current-carrying capacity curves: Determined solely by the wire gauge the use of reducers has no bearing on the maximum currentcarrying capacity curve. The values are only valid for the main contacts with w/ crimping. Reduced scale diagrams / dimensions in mm

9 Adapters Pilot contact adapter,, Multifunctional adapter Adapter options for customizing your LV-HPC Series charging connector: Pilot contact adapter Adapter to be fitted with additional pilot contacts for monitoring the battery state and other control functions. Pilot contact adapter LV30/400 Series LV160/50 Series LV80/10 Series Set*: Adapter + x socket contact LV160/30 P-S/S LV80 P-S/S Set*: Adapter + x pin contact LV160/30 P-P/S LV80 P-P/S * See also table on page 4 Air supply for batteries with electrolyte circulation system. Electrolyte circulation ensures that the electrolyte is gently mixed by an airstream while the battery is being recharged and prevents the battery acid from becoming layered in the individual cells. This results in a shorter charging time and in reduced energy and water consumption. Pilot contact adapter Adapter fitted with pilot contacts for additional control functions For receptacle shell* Spacer* LV30/400 Series LV160/50 Series LV80/10 Series LV160/30 LV-S LV160/30 DS-L LV80 LV-S LV80 DS-L For plug shell* LV160/30 LV-P LV80 LV-P * See also table on page 4 Air supply for batteries with electrolyte circulation system Multifunctional adapter Multi purpose adapter for water top up and electrolyte circulation systems. The new feature that the flow of air and/or water is shut off when the connector is unmated ensures that no acid particles enter the interior of the vehicle. For more information, especially on the multifunctional adapter: Multifunctional adapter Adapter for water top up or air supply of batteries with electrolyte circulation system Extra air tube adapters Accessories 185 173.5 LV80 LV-S LV80 LV-P LV160/30 LV-S LV160/30 LV-P Ø6 150 Air tube inside Ø 6 mm LV80 LV-S LV80 LV-P LV160/30 LV-S LV160/30 LV-P Ø6 150 Air tube inside Ø 9...10 mm Air tube Air tube For air tubes with inside diameter Ø 6 mm and thicker wall For air tubes with inside diameter Ø 9... 10 mm Do you need an adapter for air tubes with greater inside diameter or thicker walls? The extra air tube adapter becomes necessary when air tubes are used with: Inside diameter Ø 9... 10 mm Inside diameter Ø 6 mm and thicker wall Extra air tube adapter Fig. Adapter for air tube with inside diameter 6 mm and thicker wall Adapter for air tube with inside diameter 9... 10 mm LV80/160/30 V-S 6/6 LV80/160/30 V-S 6/10 Reduced scale diagrams / dimensions in mm

10 Tools Crimp tools, Extraction tools Accessories Hydraulic crimping tool Stocko WHPH 10 for the main contacts Crimp tool CWZ-600 for both pilot and auxiliary contacts w/ crimping of main contacts The applicable standard for crimping the main contacts is IEC 6035- Solderless crimped connections. Schaltbau requires w/ crimping of main contacts. For that purpose Schaltbau recommends the use of the hand tool WHPH 10 and for major quantities the hydraulic crimping heads WHK 8S, WHK 8 and WHK 9 respectively of the company Stocko. Order from: Stocko (www.stocko.de) or retailer : Stocko WHPH 10 or comparable tool of other manufacturers Crimping of pilot and auxiliary contacts The applicable standard for crimping of pilot and auxiliary contacts is IEC 6035- Solderless crimped connections. Schaltbau recommends the use of crimp tool CWZ-600 for wire sizes AWG 5... 9 (0.14... 6.00 mm²). Crimping of pilot and auxiliary contacts is done by means of a set of dies size AWG 13 (.5 mm²). For that purpose, slide crimp ferrule of contact (pin or socket) over the stripped wire until it shows in the inspection hole. Feed the contact with the inserted wire in the crimp tool as far as it will go. Close the tool handles beyond the lock-in position. Order from: Schaltbau GmbH : Crimp tool CWZ-600 Extraction tool AWZ-C/H for pilot contacts of the LV160/50 and LV30/400 series Extraction tool LV160 AWZ-B for aux. contacts of the LV160/50 series Extraction tool LV80 AWZ-B for both pilot and aux. contacts of the LV80/10 series AWZ-C/H Extraction tool for pilot and aux. contacts The tools are designed for the removal of pilot and auxiliary contacts from the assembled connector. Insert tool from front and push until contact is unlocked and can be pulled out from the rear of the connector. Series Type of contact Extraction tool / LV30/400 Pilot contact BCC-.5-Ag SCC-.5-Ag AWZ-C/H Aux. contact LV30 BCC-.5-Ag LV30 SCC-.5-Ag None* LV160/50 Pilot contact BCC-.5-Ag SCC-.5-Ag AWZ-C/H Aux. contact LV160 BBC-.5-Ag LV160 SBC-.5-Ag LV160 AWZ-B LV80/10 Pilot contact LV80 BBC-.5-Ag LV80 SBC-.5-Ag LV80 AWZ-B Aux. contact LV80 BBC-.5-Ag LV80 SBC-.5-Ag LV80 AWZ-B * Aux. contacts of the LV30/400 Series are secured from falling out of the shell by means of the slider. Assembly instructions Main contacts with w/ crimp points Even adjustment of main contacts in plug/receptacle shell improves mating and unmating forces Main contact (here: socket contact) Cable (e. g. H01N-D) Bearing surface Battery terminal end (here: cable lug) Parallel alignment of crimp points of main contacts and cable lugs to bearing surface Assembly of main contacts After assembly of the main contacts, we recommend mating of the connector halves before tightening the strain relief screws. This ensures an ideal concentricity of the main contacts. Mounting of plug or receptacle shell For mounting the plug or receptacle shell of LV160/50 and LV30/400 Series connectors onto material handling vehicles or equipment use M6 screws with Ø 6.4 mm washers (according to DIN 134). For LV80/10 Series connectors use M6 pan head and socket head screws (according to DIN 91) without washers. Tightening torque 3 Nm max. Mating and unmating forces In order to ensure easy engaging and disconnecting the mating and unmating forces should remain within normal range (150 N max.). To minimize torsion forces in the cable: adjust both main contacts evenly in the shell (see left-hand diagram) align crimp points in parallel to bearing surface of cable lug; this is particularly important in case of short cables where there is not much room for manoeuvre (see right-hand diagram)

11 Keying Voltage keying, Application keying Schaltbau charging connectors feature keying to DIN VDE 063 589. Keying plugs of different colours make it easy to identify the right connector visually. Voltage keying: There are six standard battery voltages to choose from: 4, 36, 48, 7, 80,. The voltages are marked on the sides of the hexagonal keying plug. The keyed voltage shows in the inspection hole of the plug and receptacle shell. Application keying: This type of keying only allows for mating of connector halves for the same battery type. Thus a battery receptacle for dry-cell batteries is only intermateable with the charging plug for dry-cell batteries.. Keying plug Identification Assembled in Battery Keying Charger/vehicle 4 V 7 V 4 V 7 V 4 V 7 V 4 V For high amparage HPC Used for battery Features tongue Colour RED For high amparage HPC Used for charger Features groove Colour RED Battery receptacle [ ]* 1 Charging plug [ ]* 1 Battery receptacle HPC Red 4 V * 4 V * HPC Red Grey Charging plug 4 V 4 4 V 7 7 V 4 V 7 7 V 36 4 V 96 7 V 7 V Used for Battery / charger Colour GREY Used for Battery / charger Colour GREEN Battery receptacle [ ]* 1 Charging plug [ ]* 1 Battery receptacle [ ]* 1 Dry-cell»T«Charging plug [ ]* 1 Dry-cell»T«Battery receptacle Grey Green 4 V * Yellow Charging plug Vehicle plug Universal»U«4 V 7 V Used for Vehicle Colour YELLOW Vehicle plug [ ]* 1 Universal»U«*1 Keyed voltage, shows in inspection hole: [ ] = receptacle, [ ] = plug Battery receptacle Dry-cell»T«4 V * * Cross section of mated connectors keyed to 4 V Green Charging plug Dry-cell»T«Safety instructions Disconnecting when live or under load Disconnecting the connector when live or under load is generally only permitted under exceptional circumstances or in the case of imminent danger to operational safety according to EN 1175-1. If the charging connector is used without auxiliary contacts the life of the main contacts can be considerably shortened because of contact welding when engaging or disengaging the connector. When unmating the connector when live or under load, an arc is generated. That is why disconnecting under load is prohibited in the neighbourhood of explosives and other ignition sources. Inverse-polarity protection In order to guarantee inverse-polarity protection the LV-HPC Series must always be fitted with a pilot contact adapter or an air tube adapter when intended for intermating with existing connectors of comparable design made by other manufacturers. Schaltbau, therefore, delivers LV-HPC Series connectors generally with a pilot contact adapter pre-assembled in the receptacle shell or an added air tube adapter with connectors for electrolyte circulation systems! Inverse-polarity protection guaranteed when engaging connectors of the same LV-HPC Series Visual inspections Be sure to make visual inspections regularly. Improper handling of the connector, e.g. when hitting the floor with some impact, can result in breakage, visible cracks and deformation. Defective and/or leaky parts must be replaced instantaneously!

Schaltbau GmbH For detailed information on our products and services visit our website or give us a call! with compliments: Schaltbau GmbH Hollerithstrasse 5 8189 Munich Germany Phone +49 89 9 30 05-0 Fax +49 89 9 30 05-350 Internet www.schaltbau-gmbh.de e-mail contact@schaltbau.de RoHS 011/65/EC Schaltbau GmbH manufactures in compliance with RoHS. The production facilities of Schaltbau GmbH have been IRIS certified since 008. Quality you can count on Schaltbau Certified to DIN EN ISO 14001 since 00. For the most recent certificate visit our website. Quality you can count on Schaltbau Certified to DIN EN ISO 9001 since 1994. For the most recent certificate visit our website. Electrical Components and Systems for Railway Engineering and Industrial Applications Connectors Connectors manufactured to industry standards Connectors to suit the special requirements of communications engineering (MIL connectors) Charging connectors for battery-powered machines and systems Connectors for railway engineering, including UIC connectors Special connectors to suit customer requirements Snap-action switches Snap-action switches with positive opening operation Snap-action switches with self-cleaning contacts Enabling switches Special switches to suit customer requirements Contactors Single and multi-pole DC contactors High-voltage AC/DC contactors Contactors for battery powered vehicles and power supplies Contactors for railway applications Terminal bolts and fuse holders DC emergency disconnect switches Special contactors to suit customer requirements Electrics for rolling stock Equipment for driver's cab Equipment for passenger use High-voltage switchgear High-voltage heaters High-voltage roof equipment Equipment for electric brakes Design and engineering of train electrics to customer requirements A184/1308/0.0 Printed in Germany We reserve the right to make technical alterations without prior notice. For updated product information visit www.schaltbau-gmbh.de. Issued 08-013