Product Data. SYSTXBBECC01-B Evolutionr Connext Control INDUSTRY LEADING FEATURES/BENEFITS. EVOLUTION r CONNEX t CONTROL

Similar documents
Product Data. SYSTXBBECW01-A, SYSTXBBECC01-A & SYSTXBBECN01-A Evolutionr Connext Control. EVOLUTION r CONNEX t CONTROL

Product Data. SYSTXCCITC01---B Infinityr System Control INDUSTRY LEADING FEATURES/BENEFITS INFINITYR SYSTEM CONTROL

Product Data. SYSTXBBUIZ01 -D Evolutiont Zone Control. EVOLUTION t ZONE CONTROL

Product Data. SYSTXCCUIZ01-- V Infinityt Zone Control. INFINITY t ZONE CONTROL

Installation and Start-Up Instructions

Product Data ZONEKIT4ZCAR. Comfort Zone Residential Zoning System

Installation and Start Up Instructions

INFINITY ZONING QUICK START GUIDE

SYST0101ZP Ion Damper Control Installation and Start---Up Instructions

Product Data. S Up to 19 SEER / up to 13 EER S Microtube Technologyt refrigeration system Sound

Design Guide INTRODUCTION

ULTRA-ZONE FORCED AIR ZONE CONTROLS EWC

Blank-off. HVAC unit screws. Spacer for 1" filter ILL. 3. Screw

Installation Instructions

Installation Instructions

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN. Rev.

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

Digital Room Thermostats with Touch Screen LCD

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 06/18

Screw. (Note 4) Spacer for 1" filter ILL. 3. Screw

598B TWO-SPEED AIR CONDITIONER WITH PURON REFRIGERANT. Sizes 024, 036, 048, and 060. Form No. PDS 598B.24.7

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

Two temperature sensors to protect against freezing and high head pressure in both the indoor evaporator and the outdoor condenser

Digital Fan Coil Thermostats with 0(2)-10 VDC Fan Output

SE8300 Series Installation Guide 24 Vac Low Voltage

22 POINT FULLY PROGRAMMABLE HVAC CONTROLLER

GMS9/GCS9 SERIES 93% AFUE

BAPI-Stat 3 Room Sensor

Installation Instructions

ZIP Economizer Fault Detection and Diagnostics (FDD) Table

BAPI-Com, Two Wire Multifunction Sensor with Setpoint Slider (BA/BS4SCOM) Temperature/Humidity Sensor

BAPI-Com, Two Wire Multifunction Sensor BA/BS4SCOM Temperature/Humidity Sensor Installation and Operating Instructions

SetPoint 501 and 501s Controllers Installation and Operation Manual

Installation Guide. DigiTract 4. Two Stage Heat/Cool Comfort Control System. Zoning Systems. That s all we do. Part #DT4MAN Rev.

ComfortPoint Programmable Lon, VAV/Unitary Controllers

EVlink Electric Vehicle Charging Solutions Powering the Future of Sustainable Mobility

OTEC Transfer switch open transition

Installation Manual. Mixing Box Control Systems Installation, Operation, and Maintenance Manual. 605 Shiloh Road Plano, Texas

PRODUCT PORTFOLIO. Electric Vehicle Infrastructure ABB Ability Connected Services

Product Data. Features/Benefits. 35K Bypass Terminal. 110 to 4400 cfm

Orchestrate your entire home from a single interface. The beauty of interoperability.

2011 International Comfort Products, LLC

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

APC Smart-UPS. GUIDE SPECIFICATIONS FOR 1000VA & 2000VA Smart-UPS 230VAC Uninterruptible Power Supply

BAPI-Stat 4 Room Humidity Sensor (BA/ B4 -H200 Series)

Metasys Zoning Package Installation

COIL WINDING TECNHOLOGY LINE. Advanced High-Tech Solutions for Coil Winding Process Control

Smart Wi-Fi Sprinkler Timer and Flow Meters

Metasys Zoning Package

Lester Electrical ChargerConnect App User s Guide

Cooling Capacity CFM in. w.c. (125 Pa)

INSTALLATION INSTRUCTIONS TABLE OF CONTENTS

Installation Instructions

CONNECTED SERVICEs TACHOGRAPH SOLUTIONS

SMT-150 Installer Manual

BAC Custom Engineered Controls

Installation Instructions

ZoneTouch V2 Zone Control System Installation Manual

APPLICATION GUIDE. Simplicity LINC GATEWAY OVERVIEW. 24 must be grounded close to the Simplicity LINC

Product Data. that this product meets the S 95% AFUE S Two -stage operation

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Up to 96% AFUE, Single Stage, PSC Gas Furnace EASIER TO SELL

TECHNICAL SPECIFICATIONS

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

SP-32 & SP-32D SP-33, SP-33D SP-34, SP-34D. Description. Specifications. Single Stage Temperature Control

Cooling mode. Temperature adjustment button. Override button. 24 VAC COM AN1 COM OPEN CLOSED T2/AN2 T2/COM T3 T3 COM SENSOR COM C-Over COM NSB

Silver Series Thermal Dispersion Airflow Measurement Technology

SLIMZONE CLASSIC /

Product Data. S Variable-speed ECM blower motor. S Two heating stages. S Humidity control when using a humidity sensing thermostat

CONSTANT PRESSURE CONTROLLERS

GE Measurement & Control

BAPI-Stat Quantum Temperature Sensor with Display and Slider Setpoint

Description. functions including single duct pressure dependent or pressure independent systems.

GMH95/GCH9 PRODUCT SPECIFICATIONS 95%/93% AFUE HEAT REPLACEMENT MULTI-POSITION, TWO-STAGE (CONVERTIBLE), MULTI-SPEED GAS FURNACE

CRECOMZR054B00 CRECOMZR055B00. VERTICAL AND HORIZONTAL ECONOMI$ER2 ACCESSORY MEDIUM ROOFTOP UNITS 15 to 27 1/2 TONS WARNING TABLE OF CONTENTS

BAPI-Stat Quantum Temperature Sensor with Display, Button Setpoint, Fan or System Mode Control

VisionPRO 8000 Thermostats

CM707 (UK Version) PROGRAMMABLE THERMOSTAT FEATURES PRODUCT SPECIFICATION SHEET

Orion BMS Purchasing Guide Rev. 1.2

Aurora Universal Protocol Converter (UPC) Zone Sensors. Submittal Data English Language/IP Units SD1582EW 10/14

Ductless Split Systems

EVlink Parking charging stations. Simpler for drivers. Smarter for your city.

MiG2 TIME SWITCHES. 1, 2 & 4 Channel, 365 Day, Energy Saving Time Switches

Transfer switch OTEC and OTECSE open transition

Cooling Capacity CFM in. w.c. (125 Pa)

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

CH5000 Heat Recovery Ventilator

SMT-AZC INSTALLATION / OPERATION MANUAL

Model No. DFC-X Support DIRECT FIRED DIGITAL TEMPERATURE CONTROL INSTALLATION, OPERATION, AND MAINTENANCE MANUAL

Hardware Installation. Tracer AH541 Version 2 Air-Handler Controller CNT-SVN02B-EN

Johnson Controls Rooftop Units

Combined Ventilation Controller RVWS-T-224HA

RC-DO. Room controllers with display and manual forced ventilation function

Ductless Split Systems

Installation, Service, and Troubleshooting Instructions

50JZ 7 to 14 kw ( ) STANDARD EFFICIENCY. SINGLE-PACKAGE 50 Hz. ELECTRIC HEAT PUMP UNITS with optional ELECTRIC HEAT

Control, Performance and Flexibility

Commerical Comfort System (CCS) Variable Air Volume (VAV) Zone Pressure Independent Damper Controller

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

SPECIFICATION SHEET. C5000 ( cfm)

Transcription:

SYSTXBBECC01-B Evolutionr Connext Control Product Data A12479 NOTE: Evolutionr Connext Control compatible with Evolutionr rated indoor equipment only. US Patents: Carrierr U.S. Pat No. 7,243,004, Carrierr U.S. Pat No. 7,775,452, pointsett U.S. Pat No. 7,415,102 EVOLUTION r CONNEX t CONTROL Bryantr specializes in creating a customized home comfort system tailored to your needs with our broad selection of residential heating and cooling products. The Evolutionr Connext Control is the ultimate control center for all of your system components. When you add an Evolutionr Connext Control to a compatible variable speed furnace, fan coil, Evolution r System split or package unit, or small packaged product, you will enjoy longer heating and cooling cycles at lower fan speeds for a more consistent temperature throughout your home. By adding a variable speed, multi-stage, or 2 -stage outdoor unit, you will enjoy extra benefits which include better humidity and temperature control as well as a more energy efficient comfort system. When paired with Evolutionr Zoning controls, the Evolutionr Connext Control allows you to create up to 8 zones of customized comfort. The Evolutionr Zoning system does not require a bypass damper, leaving air temperature (LAT) sensor, or field -installed power transformer. Always install the latest version of software to enable all features of the system. Over-the-Air software updates for Wi-Fi models connected to the Evolution server are automatically downloaded. Software updates via MicroSD are available on HVACpartners, or at www.myevolutionconnex.com. INDUSTRY LEADING FEATURES/BENEFITS Bryant s revolutionary Evolutionr Connext Control is the smart control of the future. Its unique system self-configuration and diagnostics capabilities make installation and service fast and accurate, helping to avoid costly call -backs. The Evolutionr Connext Control features a high resolution display, making it easier to read. Intuitive prompts let you program everything from humidity levels to fan speeds, giving you the ultimate control over your home comfort. Other features include: 2 -wire connection to Evolutionr System two or morestage outdoor equipment (including geothermal split units) 4 -wire installation from each major component in the system Evolutionr Zoning System compatibility Occupancy sensing to provide comfort when spaces are occupied; schedules can maximize energy savings Intuitive on -screen prompts for ease of installation and service Perfect Humidityt System settings are the default no longer requiring increased system setup Complete integration of the temperature, humidity and ventilation in every season Auto mode selection to satisfy simultaneous heating and cooling demands via more aggressive Auto Changeover algorithm - -installer must enable 7 -day programmability with Lifestyle Comfort Profiles and Touch -N -Gor features; complies with California Title 24 programmability requirements Easy timed -override schedule Simplified vacation schedules Day -at -a -glance programming for simplified ease of use Programmable fan by period TrueSenset Dirty Filter Detection Indoor Air Quality pop up reminders General maintenance reminder messaging Wi-Fir remote access capability Upload photo, dealer info, and software updates locally via MicroSD card. Software updates available automatically when connected to the Evolution web server Compatible with home automation through the SYSTXBBRCT01 or SYSTXBBRWF01 system access modules, or via Amazon Alexa control Compatible with communicating Evolutionr System Small Packaged Products Wi --- Fir is a registered trademark of Wi---Fi Alliance Corporation.

MODEL NUMBER NOMENCLATURE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 S Y S T X B B E C W 0 1 -- B Product Type Evolutionr System Version B Brand Bryant 01 Packaged Quantity Model Type ECC --- Evolutionr Connext Control with Wi ---Fir capability Fig. 1 - Unit Dimensions A170101 2

PRODUCT DATA INFORMATION Compatible Communicating Products Compatible with most Evolutionr System indoor and outdoor equipment built since 2004; see equipment specifications for details. Home Automation System Interface A cloud -to -cloud Open API (Application Program Interface) is available for ECC and ECW model Evolution Connex Controls. See the Evolution Systems Open API Getting Started Guide available on HVACpartners.com or contact EvolutionOpenAPI@bryant.com for more information. The Evolutionr Connext control may also connect to a variety of Home Automation systems. Note that not all Home Automation systems may be compatible. Reference the latest version of the Application Specification titled SAM Remote Access Application Specification, available on HVACpartners.com to learn more. Work with the home automation supplier to see if the systems are compatible. If not, you may provide the Evolution System Open API Getting Started Guide or the SAM Remote Access Application Specification to the home automation supplier to develop an interface with the Evolutionr Connext system. Always be sure to obtain the latest version of the application specification from HVACpartners, as we continually update and add home automation interfaces. NOTE: The ability to remotely access and adjust the settings of the Evolutionr Connext Control with the MyEvolution web and mobile applications or other system interfaces is dependent on the compatibility of the user s computer, home network, and/or mobile device, the Evolutionr Connext Control and/or the MyEvolution web server or other system interfaces with, and the the availability of, the user s Internet service provider or mobile device carrier service. Bryant Heating and Cooling Systems makes no representations or warranties, express or implied, including, to the extent permitted by applicable law, any implied, including, to the extent permitted by applicable law, any implied warranty of merchantability or fitness for a particular purpose or use, about the compatibility of the user s computer, home network, and/or mobile device, with the Evolutionr Connext Control, and/or the MyEvolution web server or other system interfaces, with, and the availability of the user s Internet service provider or mobile device carrier service, or that the ability to remotely access and adjust the settings of the Evolutionr Connext Control will not be negatively affected by the network - related modifications, upgrades, or similar activity of the user s Internet service provider or mobile device carrier service. Physical Characteristics Dimensions: See drawing Appearance: Black glass front, silver plastic body Electrical Characteristics/Communication Input Volt 24VAC Each device in the Evolutionr System has a four-pin connector labeled ABCD. It is recommended that the following color code be used when wiring each device: A Green = Data A+ B Yellow = Data B - C White = 24VAC (Com) D Red = 24VAC (Hot) Always verify that the IDU and ODU are well-grounded, and that there are less than 10 volts AC/DC as measured between the cabinets of the IDU and ODU, while the equipment is operating at full capacity. If there is a larger voltage difference between the cabinets of the IDU and ODU, recheck the equipment grounding. Environmental Requirements: Operating Temperature/Relative Humidity: User interface and all sensors: 32_F to 104_F / 0_C to40_c, 95% RH non -condensing Storage Temperature/Relative Humidity: User interface: - 40_F to 134_F /-40_C to 56.7_C, 95% RH non -condensing Feature Specifications: Temperature set point range: 50_F to90_f / 10.0_C to 32.0_C Separate heat and cool setpoints Programming days: 7 day Programming periods: Up to 5 periods per day Advanced Smart Setback (with programming) Touch -N -Gor feature Occupancy sensing Non -Programmable (installer selectable) Auto Changeover* (may be disabled) Simultaneous Heat Cool Demand Algorithm for zoned systems Programmable fan (installer selectable) Humidity Sensor Offsets Auto Changeover Timer (installer adjustable) Smart Recovery (in heating and cooling) Hold function Copy functions: copy day of week; copy zones Permanent memory Humidity display and control Temperature sensor offsets (indoor and outdoor) TrueSenset Dirty Filter Detection with compatible indoor equipment * See Installation Instructions for details on Auto Changeover and Simultaneous Heat/Cool Demand Algorithm operation. Wiring Requirements: Power supply: 24VAC, 40 VA (minimum), 60 Hz, via indoor equipment ABCD Connector. Zoning systems with a large number of dampers, especially multiple dampers per zone, may require a separate, dedicated, field -installed 24vac power supply. The SAM module requires an independent, isolated, field -supplied 24vac power supply. Wiring material: Standard thermostat wire 18 to 22 gauge. Use 18 AWG wiring for wire lengths over 25 feet. Shielded, twisted pair cable for te ABCD communication bus is optional, and may be helpful in electrically noisy environments, or for zoning systems with Smart Sensors. NIM Requirements: IDU NON---COMMUNICATING ODU NIM REQUIRED? Furnace 1 --- stage A/C No Furnace 2 --- stage A/C Yes Furnace 1 --- stage HP Yes Furnace 2 --- stage HP Yes Fan Coil 1 --- stage A/C No Fan Coil 2 --- stage A/C Yes Fan Coil 1 --- stage HP No Fan Coil 2 --- stage HP Yes 3

Evolutionr Connext Control with Wi --- Fir Remote Access Capability Evolutionr Network Interface Module (NIM) EQUIPMENT SYSTXBBECC01---B SYSTXBBNIM01* * Required for ventilator control * Required for Hybrid Heat applications with non---communicating heat pumps * Required for use with 2---stage (non---communicating) AC or HP Evolutionr Remote Room Sensor (RRS) ABCD Equipment Communication Connector (Green Plug; 10 pack) Decorative Trim Plate --- Gray (six pack) Decorative Trim Plate --- Black (six pack) Decorative Trim Plate --- White (six pack) Decorative Trim Plate --- Silver (six pack) Outdoor Air Temperature Sensor Wireless Access Point (WAP) --- Optional Evolutionr Remote Access Module, Broadband Cat---5 Wired Evolutionr Remote Access Module, Broadband Wi---Fir Wireless Accessory Power Transformer for SAM Modules** OPTIONAL ACCESSORIES SYSTXBBRRS01* SYSTXGRPLG10 SYSTXNNGB06 SYSTXNNBB06 SYSTXNNWB06 SYSTXNNSB06 TSTATXXSEN01---B SYSTXXXGWR01 SYSTXBBRCT01 SYSTXBBRWF01 SYSTXNNXFM01** * Not required, but may be used to remote sense indoor room temperature. { Backplate dimensions 6.83 in. (173.5 mm) wide X 5.97 in. (151.7 mm) high ** Available from RC/Totaline Evolutionr Damper Control Module (4 Zone) Evolutionr Smart Sensor** ZONING EQUIPMENT SYSTXBB4ZC01 SYSTXBBSMS01-E NOTE: Each piece of the zoning equipment is purchased separately allowing for customization of the zoning application. **Smart Sensor dimensions are 3.375 in. (85mm) side x 4 in. (101 mm) high { One Damper Control Module for up to 4 zones. A second Damper Control Module is required for zones 5 8. DAMPER ACCESSORIES & REPLACEMENT PARTS 45º Actuator for round dampers DAMPACT45DEG-R 90º Actuator for rectangular dampers DAMPACT90DEG-R Damper Control Module 1-amp Fuse ATO1* *Available from RC. Round Dampers Rectangular Dampers ROUND & RECTANGULAR DAMPERS 6in. DAMPRND06INC-B 8in. DAMPRND08INC-B 10 in. DAMPRND10INC-B 12 in. DAMPRND12INC-B 14 in. DAMPRND14INC-B 16 in. DAMPRND16INC-B 8in.X10in. DAMPREC08X10-B 8in.X14in. DAMPREC08X14-B 8in.X18in. DAMPREC08X18-B 8in.X24in. DAMPREC08X24-B 10 in. X 10 in. DAMPREC10X10-B 10 in. X 14 in. DAMPREC10X14-B 10 in. X 18 in. DAMPREC10X18-B 10 in. X 24 in. DAMPREC10X24-B 4

Slip-In Dampers SLIP -IN DAMPERS Side mount, 8 X 8 Bottom mount, 8 X 8 Side mount, 8 X 10 Bottom mount, 8 X 10 Side mount, 8 X 12 Bottom mount, 8 X 12 Side mount, 8 X 14 Bottom mount, 8 X 14 Side mount, 8 X 16 Bottom mount, 8 X 16 Side mount, 8 X 18 Bottom mount, 8 X 18 Side mount, 8 X 20 Bottom mount, 8 X 20 Side mount, 8 X 22 Bottom mount, 8 X 22 Side mount, 8 X 24 Bottom mount, 8 X 24 Side mount, 10 X 10 Bottom mount, 10 X 10 Side mount, 10 X 12 Bottom mount, 10 X 12 Side mount, 10 X 14 Bottom mount, 10 X 14 Side mount, 10 X 16 Bottom mount, 10 X 16 Side mount, 10 X 18 Bottom mount, 10 X18 Side mount, 10 X 20 Bottom mount, 10 X 20 Side mount, 10 X 22 Bottom mount, 10 X 22 Side mount, 10 X 24 Bottom mount, 10 X 24 Side mount, 12 X 12 Bottom mount, 12 X 12 Side mount, 12 X 14 Bottom mount, 12 X 14 Side mount, 12 X 16 Bottom mount, 12 X 16 Side mount, 12 X 18 Bottom mount, 12 X 18 Side mount, 12 X 20 Bottom mount, 12 X 20 Side mount, 14 X 14 Bottom mount, 14 X 14 Side mount, 14 X 16 Bottom mount, 14 X 16 Side mount, 14 X 20 Bottom mount, 14 X 20 Side mount, 16 X 16 Bottom mount, 16 X 16 Bottom mount, 16 X 20 DAMPSLS08X08-B DAMPSLB08X08-B DAMPSLS08X10-B DAMPSLB08X10-B DAMPSLS08X12-B DAMPSLB08X12-B DAMPSLS08X14-B DAMPSLB08X14-B DAMPSLS08X16-B DAMPSLB08X16-B DAMPSLS08x18-B DAMPSLB08X18-B DAMPSLS08X20-B DAMPSLB08X20-B DAMPSLS08X22-B DAMPSLB08X22-B DAMPSLS08X24-B DAMPSLB08X24-B DAMPSLS10X10-B DAMPSLB10X10-B DAMPSLS10X12-B DAMPSLB10X12-B DAMPSLS10X14-B DAMPSLB10X14-B DAMPSLS10X16-B DAMPSLB10X16-B DAMPSLS10X18-B DAMPSLB10X18-B DAMPSLS10X20-B DAMPSLB10X20-B DAMPSLS10X22-B DAMPSLB10X22-B DAMPSLS10X24-B DAMPSLB10X24-B DAMPSLS12X12-B DAMPSLB12X12-B DAMPSLS12X14-B DAMPSLB12X14-B DAMPSLS12X16-B DAMPSLB12X16-B DAMPSLS12X18-B DAMPSLB12X18-B DAMPSLS12X20-B DAMPSLB12X20-B DAMPSLS14X14-B DAMPSLB14X14-B DAMPSLS14X16-B DAMPSLB14X16-B DAMPSLS14X20-B DAMPSLB14X20-B DAMPSLS16X16-B DAMPSLB16X16-B DAMPSLB16X20-B 5

E2017 Bryant Heating & Cooling Systems D 7310 W. Morris St. D Indianapolis, IN 46231 Edition Date: 05/17 Catalog No. PDSSYSTXBBECC---01 Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations. Replaces: New 6