How Much Can a Campus Save on Utility Bills By Turning a 5-Workday Week Into a 4-Workday Week?

Similar documents
Meter Insights for Downtown Store

Portland General Electric Company Eleventh Revision of Sheet No. 7-1 P.U.C. Oregon No. E-18 Canceling Tenth Revision of Sheet No.

BrightRidge Large Commercial and Industrial Rates October 2017 Billing Cycle All Rates Subject to TVA s Fuel Cost Adjustment (separate schedule)

The impact of electric vehicle development on peak demand and the load curve under different scenarios of EV integration and recharging options

How it works How your HAN device helps you monitor electricity use

Phone (602) Toll Free (800) Fax (602) CALENDAR OF FILING DEADLINES AND SEC HOLIDAYS

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. TIME-OF-USE GENERAL POWER RATE--SCHEDULE TGSA (November 2018)

Small General Service Time-of-Use Rate Schedule GS-TOU3

WIM #48 is located on CSAH 5 near Storden in Cottonwood county.

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after January 1, 2014.

PET(S) FIRST & LAST NAME: January 2019

WIM #37 was operational for the entire month of September Volume was computed using all monthly data.

Per Meter, Per Month. Effective July 1, 2018 Customer Charge Flat Charge $8.86

FLORENCE ELECTRICITY DEPARTMENT. GENERAL POWER RATE--SCHEDULE GSC (October 2015) Availability

Manitoba Hydro Customer Consultation. Industrial Rates Workshop

VC ACADEMIC CALENDAR. Sun Mon Tue Wed Thu Fri Sat. Sum 10 Wk. & Sum II Final Exams. Cancel Fall 16 wk. & Fall I Non-Pays

Energy Performance Information Request Timeline

TERRITORY: This rate schedule applies everywhere PG&E provides electric service. I

A Guide to the medium General Service. BC Hydro Last Updated: February 24, 2012

NORTHEAST NEBRASKA PUBLIC POWER DISTRICT RATE SCHEDULE LP-2 Large Power Service. Effective: For bills rendered on and after February 1, 2019.

ELECTRIC SCHEDULE AG-ICE Sheet 1 AGRICULTURAL INTERNAL COMBUSTION ENGINE CONVERSION INCENTIVE RATE - EXPIRATION TRANSITION RATE

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

Effect of DG Installation on Customer Load Shapes

WIM #41 CSAH 14, MP 14.9 CROOKSTON, MINNESOTA APRIL 2014 MONTHLY REPORT

RATE APPLICATION MANUAL. Kansas City Board of Public Utilities

Driver Speed Compliance in Western Australia. Tony Radalj and Brian Kidd Main Roads Western Australia

ENERGY MANAGEMENT AT COOPER TIRE

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-27 CUSTOMER GENERATION PRICE PLAN FOR RESIDENTIAL SERVICE

North Dakota Commercial and Industrial Electric Prices

PAG Environmental Planning Advisory Committee Sun Link Streetcar Update May 1, 2015

CALENDAR OF FILING DEADLINES AND SEC HOLIDAYS

Executive Summary. Solid Waste Management Program Analysis and Recommendations for Silver City, New Mexico

Commu 2018 nity Calendar

EXPERIENCE IN A COMPANY-WIDE LONG DISTANCE CARPOOL PROGRAM IN SOUTH KOREA

Prairie View A&M University Whole Campus Energy Analysis. Final Report. Prairie View A&M University. The Governor's Energy Office

2012 Water Consumption Statistics Report. Water Services Department

Use of National Household Travel Survey (NHTS) Data in Assessment of Impacts of PHEVs on Greenhouse Gas (GHG) Emissions and Electricity Demand

September 21, Advice No , NEW Schedule 50 Retail Electric Vehicle Charging Rates

FLORENCE ELECTRICITY DEPARTMENT. MANUFACTURING SERVICE RATE--SCHEDULE TDMSA (October 2015) Availability

Annex 1. Field Report: Solar Electric Light Fund Energy Harvest Control Study

Revised Cal. P.U.C. Sheet No E Cancelling Original Cal. P.U.C. Sheet No E

PERPETUAL CALENDAR. Fall Semester August September October November December S M T W H F S S M T W H F S S M T W H F S S M T W H F S S M T W H F S

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. Availability

Michigan. Traffic. Profile

Provisional Review of Fatal Collisions. January to December 31 st 2017

Docket No EI Date: May 22, 2014

Residential Time-of-Day Service Rate Schedule R-TOD

CHOOSE TOSAVE. Take control of your electric bill by choosing the pricing plan that is right for you. Time-of-Use. Peak Demand. Demand Time-of-Use

Residential Lighting: Shedding Light on the Remaining Savings Potential in California

Plug- in Electric Vehicles History, Technology and Rates. Ben Echols

Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017

Use the calendars that follow for your request. Write in your arrival times and leaving times on all dates requested.

WIM #29 was operational for the entire month of October Volume was computed using all monthly data.

Large Power Service Time of Use

Key Findings. February 2009 Caltrain Annual Passenger Counts

MARKET RATES UPDATE Paula Gold-Williams Cory Kuchinsky

10605 Central Ave NW Albuquerque, NM For Reservations call (505) Direct Line (505) ext.1000

CHOOSE TOSAVE. Take control of your electric bill by choosing the pricing plan that is right for you. Time-of-Use. Peak Demand. Demand Time-of-Use

MISSOURI SERVICE AREA

DRIVER SPEED COMPLIANCE WITHIN SCHOOL ZONES AND EFFECTS OF 40 PAINTED SPEED LIMIT ON DRIVER SPEED BEHAVIOURS Tony Radalj Main Roads Western Australia

Michigan. Traffic. Profile

CITY OF LOS ANGELES INTER-DEPARTMENTAL MEMORANDUM

WIM #40 US 52, MP S. ST. PAUL, MN APRIL 2010 MONTHLY REPORT

Schedule TOU-EV-7 Sheet 1 GENERAL SERVICE TIME-OF-USE, ELECTRIC VEHICLE CHARGING

National Household Travel Survey Add-On Use in the Des Moines, Iowa, Metropolitan Area

Docket 50-ER-108 Algoma Utilities. Final Form Rate and Rule Tariff Sheets Amendment 78. Filed By: Public Service Commission of Wisconsin

WAKE TRANSIT PLAN Summer 2018

Group 3: Pricing from 1 April 2018 and load management

Cost Reflective Tariffs

11. Electrical energy tariff rating

Revised Cal. P.U.C. Sheet No E Cancelling Revised Cal. P.U.C. Sheet No E

Agricultural Service Rate Schedule AG

SALT RIVER PROJECT AGRICULTURAL IMPROVEMENT AND POWER DISTRICT E-21 PRICE PLAN FOR RESIDENTIAL SUPER PEAK TIME-OF-USE SERVICE

WIM #39 MN 43, MP 45.2 WINONA, MN APRIL 2010 MONTHLY REPORT

CAMPUS CONNECTOR MONDAY - THURSDAY. bold italicized times denote p.m. Monday - Thursday continued on next page. Effective August 29th, 2016

FOR IMMEDIATE RELEASE

Schedule TOU-EV-8 Sheet 1 GENERAL SERVICE TIME-OF-USE, ELECTRIC VEHICLE CHARGING, DEMAND METERED

July 24, Project IR

Working through the electric motor replacement maze

STANDBY SERVICE. Transmission Service Primary Service Secondary Service

Madison BRT Transit Corridor Study Proposed BRT Operations Plans

ELECTRIC POWER BOARD OF THE METROPOLITAN GOVERNMENT OF NASHVILLE AND DAVIDSON COUNTY. LARGE MANUFACTURING SERVICE RATE SCHEDULES (November 2018)

WIM #40 is located on US 52 near South St. Paul in Dakota county.

EXHIBIT A ORDINANCE NO. O CITY OF LAURINBURG, NORTH CAROLINA SCHEDULES OPR RESIDENTIAL TIME-OF-USE SERVICE

Water Consumption Statistics Report

Agenda Cover Memorandum

Technical Memorandum Analysis Procedures and Mobility Performance Measures 100 Most Congested Texas Road Sections What s New for 2015

Expansion Projects Description

Electric Rates. for residential and farm customers. January 2016

SERVICE CLASSIFICATION NO. 7 LARGE GENERAL TIME-OF-DAY SERVICE

NCAA Division I Championship Subdivision Football Recruiting Calendar August 1, 2017, through July 31, 2018

Schedule D DOMESTIC SERVICE

C-BOA Tool. Comparison of Peak Demand Savings Estimation Methods. February 7, of 14

STANDBY SERVICE. RULES AND REGULATIONS: Terms and conditions of this schedule and the General Rules and Regulations govern use of this schedule.

FOR IMMEDIATE RELEASE

ENERGY MANAGEMENT 4/22/2014. What are your approximate yearly energy costs? (Electricity, natural gas, etc.)

Rate Schedules. Effective 1/1/2019

Power Metrics International INC Richmond Terrace Staten Island, NY 10302

2017 Adjusted Count Report February 12, 2018

Oregon Withholding Tax Tables

Transcription:

How Much Can a Campus Save on Utility Bills By Turning a 5-Workday Week Into a 4-Workday Week? Jijun Zhou Research Associate Energy System Laboratory Texas A&M University Guanghua Wei, P.E. Assistant Research Engineer Energy Systems Laboratory Texas A&M University Tim Giebler Research Associate Energy Systems Laboratory Texas A&M University Dan Turner, Ph.D., P.E. Professor Dept. of Mechanical Engineering Texas A&M University ABSTRACT The recent budget cuts campaign mandated by the governor s office had all state agencies in Texas looking for ways to reduce revenue spending. One of the cost savings opportunities perceived by many university officials is to convert a typical 5-workday week into a 4- workday week (e.g., Monday to Thursday) with 10 working hours each day during the universities summer session. The potential savings come from the fact that the universities can be partially shut down during the prolonged weekends (Friday to Sunday). It is believed that the savings from partially shutting down an extra workday is much more significant than the marginal energy increase caused by the extended working hours during workdays. This paper analyzes the potential energy cost savings of this approach for three real cases. The savings can be largely estimated by comparing whole-campus electricity consumptions between typical weekdays and weekends (or holidays). Energy overheads caused by the extended working hours (two more hours per working day) were also estimated. A limited shutdown scenario (similar to a typical weekend schedule) and a more aggressive shutdown scenario (similar to a typical holiday schedule) during the weekend periods are presented. The potential savings opportunities were from 0.32% to 1.53% of the annual electricity bills for different universities. INTRODUCTION Several universities within the Texas A&M University Systems were investigating the possibility of utility energy savings by switching from a typical 5-workday week to a 4-workday week during the university s summer session (June August). The four working days are Monday through Thursday, 10 hours a day. By converting Friday from a typical weekday to a weekend day, the university will shut down most of the entire campus during the 3-day weekend, just like a long holiday (Christmas Break). Potential savings were estimated for three universities Texas A&M University at Corpus Christi, Prairie View A&M University and Texas A&M International University, to help university officials make decision as whether it is worthwhile to take this approach in an effort to cut utility expenditures. CASE STUDY I TEXAS A&M UNIVERSITY AT CORPUS CHRISTI Texas A&M University Corpus Christi (TAMUCC) has a total conditioned area of approximately 1 million square feet, with a total annual electricity bill of nearly $1.5 million in the year of 2002. The summer months applicable for 4-workday weeks are June, July and August. The weighted average electricity price during this period is $0.0457/kWh from Monday to Friday, and $0.0359/kWh for Saturday and Sunday, based on the current electricity utility contract between the university and the utility company.

Whole Campus Electric (kwh/day) 110,000 100,000 90,000 80,000 70,000 60,000 50,000 40,000 TAMUCC Whole Campus Electricity vs. Outside Air Temperature Weekday Weekend Holiday Poly. (Weekday) Poly. (Weekend) Poly. (Holiday) 30,000 20,000 34 36 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 Outside Air Temperature (deg F) Figure 1. TAMUCC Daily campus electricity consumption for weekdays, weekends and holidays Figure 1 shows the whole campus electricity (WCE) consumption (daily) profiles for weekdays, weekends and holidays. Daily WCE difference between a typical weekday and a typical weekend is around 20,000 kwh; Daily WCE difference between a typical weekend and a typical holiday is around 10,000 kwh; Daily WCE difference between a typical weekday and a typical holiday is around 30,000 kwh. Interestingly, the prolongation of 2 hours during the working days (Monday through Thursday) probably will not increase the campus HVAC load substantially. Most of the air-handing units had been operated from around 6:30 a.m. to 10:30 p.m. anyway though the working hours were from 8:00 a.m. to 5:00 p.m. Upon switching to the 4-working-day week schedule, operating schedules for most airhandling units schedules will remain unchanged for the 10-hour working days. Activity related electricity consumption (lighting, computers, printers, and other plug loads) during the four working days (Monday to Thursday) would be slightly higher than the current level due to the prolongation of the working hours. Assume that 25% of the campus lighting and other plug loads (mainly offices) would need to run 2 more hours per working day, or 8 hours a week, and that the average campus office lighting and plug loads is 2 Watts per square foot. For a total campus area of approximately 1,000,000 square feet, this amounts to an increase in electricity consumption of around 4,000 kwh per week due to the extra 2 hours from Monday to Thursday. Based on the above assumptions and analysis, the potential energy cost savings for a 4-workday week (instead of a 5-workday week) are calculated for the following two scenarios. Scenario 1 Limited Shutdown Under this scenario, the campus will be partially shutdown on Fridays and Saturdays, just like the typical weekend operation. The campus will be shutdown more aggressively on Sundays, like the typical holiday operation.

Table 1. TAMUCC: Breakdown of 4-weekday week WCE savings for limited shutdown scenario Weekly Electricity Savings (kwh) Total Weeks Subtotal Savings (kwh) Electricity Price ($/kwh) Subtotal Savings ($) Mon - Thu (4,000) 12 (48,000) 0.0457 $ (2,193.60) Friday 20,000 12 240,000 0.0457 $ 10,968.00 Saturday - 12-0.03592 $ - Sunday 10,000 12 120,000 0.03592 $ 4,310.40 Total 312,000 $ 13,084.80 Table 2. TAMUCC: Breakdown of 4-weekday week WCE savings for extensive shutdown scenario Weekly Electricity Savings (kwh) Total Weeks Subtotal Savings (kwh) Electricity Price ($/kwh) Subtotal Savings ($) Mon - Thu (4,000) 12 (48,000) 0.0457 $ (2,193.60) Friday 30,000 12 360,000 0.0457 $ 16,452.00 Saturday 10,000 12 120,000 0.03592 $ 4,310.40 Sunday 10,000 12 120,000 0.03592 $ 4,310.40 Total 552,000 $ 22,879.20 100,000 90,000 80,000 70,000 May 2003 Whole Campus Electricity Consumption (kwh/day) (Memorial-day holiday shutdown period May 23-26 shown in patten) 90.0 88.0 86.0 84.0 kwh/day 60,000 50,000 40,000 30,000 20,000 10,000 82.0 80.0 78.0 76.0 74.0 72.0 deg F 0 T F S S M T W T F S S M T W T F S S M T W T F S S M 70.0 Figure 2. TAMUCC whole campus electricity daily consumption and outside air temperature

Table 3. TAMUCC: Electricity consumption of the 4-workday-week vs. the baseline week WCE kwh Savings Energy Costs $ Savings Average OAT 5-work-day week (May 12-May 18) 479,532 kwh $ 18,868.63 84.16 4-work-day week (May 19-May 25) 424,495 kwh 55,037 kwh $ 16,629.71 $ 2,238.92 84.11 This essentially converts the Fridays into weekends and Sundays into holidays, in terms of electricity energy consumption. The Saturdays remain the same. Total savings potential is estimated at $13,084 for this shutting down scenario, or approximately 0.87% of the year 2002 electricity bill. Table 1 shows the savings breakdown. Scenario 2 Extensive Shutdown This essentially converts all three days into holidays. Total savings potential is estimated at $22,879 for this shutting down scenario, or approximately 1.53% of the year 2002 electricity bill. Table 2 shows the savings breakdown. reduction measure (ECRM) was studied for the university due to state budget shortfall. Daily electricity consumption and averaged ambient temperature data from May 22 to August 19, 2002 were used for the analysis. Two scenarios were considered. The first scenario uses the Saturday profile as the baseline and calls for a limited shut down for Friday operation. The second scenario uses the Sunday consumption profile as the baseline and calls for a similar operating schedule during Fridays and Saturdays. Estimated annual energy savings are $7,021 and $13,001 for the two scenarios, respectively. This represents 0.32% to 0.6% of the total annual electricity costs. Verification The savings projection was verified with real data when the university practiced its first extensive shut down from May 23 to May 26, 2003 (the Memorial Day). Operating schedules for major HVAC equipment during this period was similar to those for holidays. Figure 2 shows the whole campus daily electricity consumption data for the period from May 01 to May 26, 2003. It is easy to notice the reduced electricity consumption during the long Memorial holiday weekend (Friday to Monday). Compared with the week immediately prior to it, electricity consumption during the 4- workday week was reduced by 55,037 kwh, as shown in Table 3. The actual cost savings was around $2,239 per week, which is higher than the estimated savings of $1,906 per week. CASE STUDY II PRAIRIE VIEW A&M UNIVERSITY Prairie View A&M University (PVAMU) is located in Prairie View, Texas. The weather is typical for south central Texas, hot and humid in summer and mild in the winter. The total conditioned area is approximately 1.3 million square feet. Similar energy consumption Whole Campus Electricity Consumption Patterns Figure 3 is a time-series plot showing whole campus electricity consumption from May 22 to August 19, 2002. Also included is the ambient temperature for that period. Figure 4 is a scatter plot showing weekday energy consumption vs. weekend consumption. Also included is a holiday profile (Memorial Day, July 4, Christmas break) to show consumption data for a complete shutdown. The potential energy savings were evaluated based on the following conditions and assumptions. The extra two hours of operation during the four workdays will not increase the HVAC load substantially since all air handling unit operating schedules remain the same during the work day. The new schedule will be implemented from May 19, 2003 to August 16, 2003, for a total of 13 weeks period. Current operation practice turns off heating when ambient temperature is over 70 F or so. Therefore, no gas energy savings are estimated. The avoided cost of electricity energy is $0.046/kWh. No demand savings are considered since the new operating schedule will not have significant impact on electric demand.

140,000 100 Daily Electricity Consumption (kwh) 120,000 100,000 80,000 60,000 40,000 20,000 95 90 85 80 75 70 Averaged Ambient Temperature (F) 0 65 5/22/02 5/29/02 6/5/02 6/12/02 6/19/02 6/26/02 7/3/02 7/10/02 7/17/02 7/24/02 7/31/02 8/7/02 8/14/02 Electricity Consumption (kwh) Averaged Ambient Temperature (F) Figure 3. PVAMU whole campus electricity consumption for summer of 2002 Daily Electricity Consumption (kwh) 140,000 130,000 120,000 110,000 100,000 90,000 80,000 Monday-Friday Saturday Sunday Holidays Linear (Monday-Friday) Linear (Saturday) Linear (Sunday) 70,000 60,000 50 55 60 65 70 75 80 85 90 Averaged Ambient Temperature (F) Figure 4. PVAMU: Scatter plot of the consumption vs. averaged ambient temperature

Table 4. PVAMU: Breakdowns of potential savings for a limited shut down. Weekly Electricity Savings (kwh) Total Weeks Energy Savings (kwh) Cost Savings* Monday - Thursday (5,260) 13 (68,380) $ (3,145) Friday 17,000 13 221,000 $ 10,166 Saturday - 13 - $ - Sunday - 13 - $ - Total 152,620 $ 7,021 * The number in parenthesis is negative cost savings, or cost penalties Table 5. PVAMU: Breakdowns of potential savings for a complete shut down. Weekly Electricity Savings (kwh) Total Weeks Energy Savings (kwh) Cost Savings Monday - Thursday (5,260) 13 (68,380) $ (3,145) Friday 22,000 13 286,000 $ 13,156 Saturday 5,000 13 65,000 $ 2,990 Sunday - 13 - $ - Total 282,620 $ 13,001 In Figure 4, the linear trend lines represent the statistical average value for each data group. Daily electricity consumption difference between Saturday and Sunday is approximately 5,000 kwh; Daily electricity consumption difference between weekday and Sunday is about 22,000 kwh. Electricity consumption profile during the workdays will be similar to current usage. However, activity related electricity consumption in offices during the four workdays would be slightly higher than the current level due to the prolongation of the working hours (lights, computers, printers, copy machines and other plug loads will stay on longer if they are currently being turned off at 5:00pm or 6:00 pm). Assuming that 25% of the campus lighting and other plug loads (mainly offices) would need to run 2 more hours per working day, or 8 hours a week, and that the average campus office lighting and plug loads is 2 Watts per square foot. For an area of approximately 1,300,000 square feet for major buildings, this amounts to an increase in electricity consumption of around 5,200 kwh per week. 4-workday/week operation (instead of a 5- workday/week operation) is calculated for the following two scenarios. Scenario 1 - Limited shutdown on Fridays, i.e., Friday operation will be similar to current Saturday operation. Sunday s operation remains the same. Total savings potential is estimated at $7,021, or approximately 0.32% of the total annual electricity costs, as shown in Table 3. Scenario 2 - Complete shutdown on Fridays and Saturdays, i.e., Friday and Saturday s operation will be similar to current Sunday operation. Sunday s operation remains the same. Total savings potential is estimated at $13,001, or approximately 0.60% of the total annual electricity costs, as shown in Table 4. CASE STUDY III TEXAS A&M INTERNATIONAL UNIVERSITY Texas A&M International University (TAMIU) is located in Laredo, Texas. The weather is very hot in the summer and moderate in the winter. The hot weather typically lasts more than half of the year. The total conditioned area is approximately 565,000 square feet. Results Based on the above assumptions and analysis, the potential energy cost savings for a

Whole Campus Electric (kwh / day) 45,000 40,000 35,000 30,000 25,000 TAMIU Whole Campus Electric vs. Outdoor Air Temperature data points for all available days weekday holiday weekend Linear (weekday) Linear (weekend) All available June, July, and August 2002 data points are located in this temperature range 20,000 38 40 42 44 46 48 50 52 54 56 58 60 62 64 66 68 70 72 74 76 78 80 82 84 86 88 90 92 Outdoor Air Temperature ( F), from 3/11/02 through 2/4/03 Figure 5. TAMIU whole campus electricity for weekdays, weekends and holidays Whole campus 15-minute electric data was readily available because of metering installed at the central plant. The campus electric data was examined from March 10, 2002 through February 4, 2003. Data were analyzed for the Monday through Friday workweek, weekends, and holidays time periods. The holidays taken into account were Spring Break (3/14 and 3/15), July 4 th, Thanksgiving Break (11/28 and 11/29), Christmas Break (12/23/02 1/1/03), and Martin Luther King Jr. Day (1/20/03). The National Weather Service (NWS) outdoor temperature data for the Laredo airport were averaged on a daily basis for examination of the temperature dependency of the campus electricity consumption. The weekend electrical profile on average is 5,000 to 6,000 kwh per day lower than the Monday through Friday average during the warm weather. Examination of the data showed a maximum of 10,000 kwh / day difference. The present energy charge is $0.047 / kwh. The savings per week would be approximately $330 if the TAMIU operated all three days like the current Sunday profile. If Friday was operated like the current Saturday, i.e. a partial shutdown for both Friday and Saturday and then a complete shutdown on Sunday, the savings would be about $235 per week. Therefore, expected savings from a 4-day workweek, for 13 weeks, would vary from $3,000 to $4,300 (or 0.62% to 0.89% of the annual electricity bill), depending on whether there was complete or partial campus shutdown. CONCLUSIONS Energy savings by turning a typical 5- workday-8-hour week to a 4-workday-10-hour week during summer months were investigated for three independent universities within the Texas A&M University Systems. The estimated cost savings range from 0.32% to 1.5% of the annual electricity bills for different shutdown scenarios. Potential energy savings are mainly dependent on the activity level of weekends and holidays as compared to normal working days. The bigger the difference is, the bigger the energy savings are. It is worth mentioning that universities may enforce activity-related plug loads to the lowest level during the prolonged weekend (Friday to Sunday) to maximize the energy savings. The energy consumption during these weekends may be reduced to a level even

lower than typical holidays for similar weather conditions. AKNOWLEDGEMENTS The authors of this paper would like to thank the physical plant directors and the HVAC supervisors of the three universities involved in this study for their generous support in providing some important operational data. This study is partially funded by the TAMUS Energy Systems Lab s continuous commissioning projects contracted with these universities.