Vigilec doble. Pump controlller and protection for two (3ph/1ph) pumps INSTALLATION AND OPERATION

Similar documents
Pump controller and protection for one pump Multicontrol. +info: INSTALLATION AND OPERATION. Mod. Vigilec mini (V1N)

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

ECONOMISER SERIES E2T USER MANUAL

SPEEDRIVE INSTRUCTIONS MANUAL

Application Engineering

TPAK Series COOLANT PUMP

CONTENTS. Earth leakage and overload/short circuit protection systems with self-reclosing Associated breaking element

Application Engineering

MODEL 422 Submersible Pump Controller

Combined Ventilation Controller RVWS-T-224HA

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

NOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

DIN Rail UPS DC UPS/Battery Detection System Model: BDS-DIN-UPS Installation/Operation Manual

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

DIN Rail UPS Model: DIN-UPS Installation/Operation Manual

Install a module ME or MT

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

DEEP SEA ELECTRONICS PLC

KD LV Motor Protection Relay

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

Installation and Operating Instructions

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

ALIEM USER MANUAL R. Bocconi. REV. DATE Checked and Approved R. T.

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

TPHK Series Immersible Pump

SDS Enclosed Star-Delta Starter User Guide

Instruction Manual. Q Series 2 Motor Control Modules - OEM

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

Document: PRODSPEC-140 Revision: G DCN No Date: October 1, 2014 Product: 10-amp EnerGenius NRG Battery Charger

1. GENERAL SAFETY INSTRUCTIONS 2. GENERAL SAFETY RULES GENERAL OBSERVATIONS.

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

Product selection table

INSTRUCTION AND USE MANUAL

Protection and control. Self-reclosing overload and earth leakage protection

OPERATING INSTRUCTIONS MCP-MT1

Bulletin 825 SMM Smart Motor Manager

DKG-114 MANUAL AND REMOTE START UNIT

Compact System NRGS 11-2 NRGS Original Installation Instructions English

OPERATING INSTRUCTION: DGC-6D/6D1I

MODEL 235P INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 08/2009 II_235P_B1

Code: FPT F32AM1A MECC-ALTE ECP 28-VL / 4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 30,0/24,0 32,5/26,0 46,97 ESPAÑA

MANUAL CONTROL UNIT FOR ROTATING HEAT EXCHANGER. MicroMax. Article no. F IBC control Made in Sweden

Designed for ease of integration with automation systems

BIGLA30-T/BIELA14-T Event Codes Quick Reference EXPLANATION CORRECTIVE ACTION PARTS TO CARRY ON SERVICE CALL

Code: DEUTZ BF4M 1013 FC MECC-ALTE ECP 34-1L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP)

TECHNICAL SPECIFICATIONS

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

BE SURE POWER IS DISCONNECTED PRIOR TO INSALLATION! FOLLOW NATIONAL, STATE, AND LOCAL CODES! READ THESE INSTRUCTIONS ENTIRELY BEFORE INSTALLATION!

Code: VOLVO TAD 731 GE MECC-ALTE ECP 34-2L/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 150,0/120,0 165,0/132,0 238,44

SB 2000 PUSH TO SEARCH NEXT STAG E. Aerotech, Inc. FORM: QM 1320

Flight Systems. Replacement for KASSEC DESCRIPTION

Installation and Operating Instructions

EC DECLARATION OF CONFORMITY

IBC control. MicroMax MANUAL. With adjustable boost function and threshold value. Since Set of EMC-glands as an option

Protection and control P. 1 /2. Smart earth leakage protection

Code: KOHLER KDI1903M MECC-ALTE ECP 28-M/4. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 18,9/15,2 20,8/16,6 30,07

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Frequency changer variable speed pressure booster units

INSTRUCTION MANUAL MODEL PS VDC POWER SUPPLY

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

HGM1770 Automatic Generator Control Module OPERATING MANUAL Smartgen Electronic

HF 32/1/B Universal load cell

MVE2XX. Globe Valves Actuators. Power. Model Force (N)

PVM 5 PVM 10 PVM 15 PVM 20 PVM 32 FCD20 FCD 20 FCD 30 FCD 40 FC. 20 FC. 30 FC. 40 FC. 20 FC. 30 FC. 40 FC. 20 FC. 30 FC. 40

3200NT Timer Service Manual

Brake Pack SB50W. Standard AC Motors A-143. Standard AC Motors Intro duction. Brake Pack. AC Speed Control Motors Inverter.

TECHNICAL MANUAL. Inverter / Charger Combi. Combi SW 12V 1600VA Réf : PF Combi SW 24V 3800VA Réf : PF NOT_COMBI_SW-00

MANUAL ELECTRIC FIRE PUMP CONTROLLERS METRON SERIES M450

PD-Series Ground Fault Circuit Protection

ADVANCED PID TROUBLESHOOTING

Emotron DCM Control Unit

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Cat/DCG-6D1I/07-08/03/Ver 1 Page 2/10

USERS MANUAL MCD REMOTE OPERATOR

Type SOQ Negative Sequence Time Overcurrent Relay

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

Heavy duty slurry pumps

R & D SPECIALTIES ROTROL I USER'S MANUAL

SYMBOL LEGEND DANGER WARNING NOTE THIS INDICATES DANGER TO THE LIFE AND HEALTH OF THE USER IS APPROPRIATE PRECAUTIONS ARE NOT TAKEN

SDM72 Start on Demand Modules

ASSA ABLOY Series Power Operator Installation and Instruction ASSA Manual ABLOY ASSA ABLOY

DEEP SEA ELECTRONICS PLC

CONTROL UNIT OMEGA 800-R. User manual

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Controls. THERMAL OVERLOAD RELAYS RW..D (up to 40A)

NRBM Series. Between main circuit terminals: 2,000V AC, 1 minute Between main circuit and auxiliary contact: 2,000V AC, 1 minute

NEW ZEALAND POST OFFICE NEGATIVE 50V D.C. TO POSITIVE 50V D.C. SUPPLY NOTES PR 2157 ISSUE 1 APRIL 1977

DUAL DIGIT COUNTDOWN TIMER MANUAL

User Manual. T6 Tachometer. Online: Telephone: P.O. Box St. Petersburg, Florida 33736

Code: VOLVO TAD 734 GE MECC-ALTE ECO 38-1LN. VOLTAGE HZ PHASE COS Ø PRP kva/kw LTP kva/kw AMP. (LTP) 400/ ,8 250,0/200,0 275,0/220,0 397,4

ECU-02 Ver2.1 Automatic Engine Control Unit Operators Manual

HIB Enclosed Inverter User Guide

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

3.0 CHARACTERISTICS E Type CO-4 Step-Time Overcurrent Relay

Transcription:

V2P/V2T Vigilec doble INSTALLATION AND OPERATION V2P V2T Pump controlller and protection for two (3ph/1ph) pumps (V2P: control by pressure switches/ V2T: control by pressure transducer)

General Description Control and protection unit made for two pumps with automatic alternation, operated by two pressure switches (V2P) or by a built-in pressure transducer (V2T). Three-phase and single-phase. Dual voltage supply: 230 / 400 VAC. Automatic pump alternation in case of failure or deactivation of one of them. Electronic overload protection relays, adjustable from 0 to 13 A. Air-break detection in booster tanks (selectable). Phase failure protection. Mains power switch. Power contactor. MAN-0-AUTO selection by push button (for each pump). Pilot lights for VOLTAGE, ON / OFF, LOW LEVEL and OVERLOAD. Alarm reset push button. Dry running protection by level probes controller or fl oat. Remote control by contact or voltage from 6 to 400 VAC / VDC. Pump and air-break alarm contact outputs. All the control elements at 12 VDC, and isolated for a higher safety. High protection cable gland. Magnetic circuit breaker (MCB) Power Protection. Installation Mounted on a wall. Clevis mounting in detail Clevis screws to box Depth: 120 mm. Box (Backside) Clevis screws to wall CLEVIS Sheet 2

Front configuration A ON/OFF push button: AUTOMATIC mode (fi xed green circle light): Push this button to get the unit working automatically, according to established controls and protections. MANUAL mode (fl ashing green circle light): Press this button for at least 4 seconds to force the pump running, remaining the pump temperature protection only. Release the button to get back to automatic mode. D C A B G E F B STOP button. Stops the motor and doesn t allow starting it under any circumstances. If there is a voltage failure, the selected position (STOP or AUTO) remains in memory, continuing the selected mode once voltage is restored. C MOTOR ALARM. Red pilot light. D MOTOR RUNNING. Green pilot light. E LOW LEVEL. Amber pilot light. Switched off when high level fl oat is deactivated. F RESET push button. Resets the unit after overload, and keeps alarm for 5 minutes (acoustic device etc). G VOLTAGE green pilot light. Illuminated if powered. Sheet 3

230V 0 1 L1 T1 2 3 L2 T2 4 5 L3 T3 6 I O 13 NO 14 A1 A2 1 L1 T1 2 3 L2 T2 4 5 L3 T3 6 I O 13 NO 14 A1 A2 AIR 3 2 1 4 5 6 7 8 9 + Internal configuration A Control and selection voltage (0,1A). B Magnetic circuit breaker. 400 V C Main switch. D Contactors. 230 V P E Transformer. F Conector. 1 5 3 Kg/cm G Set-point pressure adjust (mod. V2T). 2 6 4 H I Maximum current adjust. Control terminal blocks. L N N L R N S T C MOTOR 1/2 2 4 6 2 4 6 U V W L N AIR ALARM MIN MAX REMOTE P1 P2 J Pressure sensor (mod. V2T). Check that all the connections are correct and that the selection voltage fuse is positioned correctly. Installation We recommend to connect individual connecting tag wires to the terminal block. 1) Open unit and move up the top, like in fi gure, to facility the connection and adjustment unit. General switch should be in OFF position. 2) Connect MAINS SUPPLY directly to MAIN SWITCH. 3) Connect the MOTORS directly to the respective contactors. 4) Connect the pressure switches to the respective terminals: P1 : High pressure; P2 : Low pressure. Mod. V2P. 4) Install the adaptor in the pressure tank, as high as possible, in the air chamber. Connect the fl exible pipe between the adaptor and the unit. Mod. V2T. 5) Connect the PROBES (if it is neccesary) to the respective TERMINALS (1: minimum, 2: maximum). Lower probe (yellow) will be install some centimetres higher than the Sheet 4

pump intake. Upper probe (red) will be install according to level and volume well, at suitable height for a greatest advantage of fl ow well performance. The cables of probes will be suffi ciently isolated, since a reinforcement contact or leak to earth could cause a bad operation of the equipment. The maximum longitude recommended for the cables of probes is of 300 mts. and the minimum section, 0,5 mm². A correct ground connection it is essencial for the effective operation of the level control. It is recommended to connect to any point of the pipe or the pump (screw, fl ange, valve), to a pick, or by means of a third probe submerged in the bottom of the recipient, in case this was insulating (glass fi ber and plastics in general). Protected against wrong connections. 6) REMOTE terminals can be connected to a remote control device (See Starting). Protected against wrong connections. If this input is not used, it must also be linked. 7) The controller offers two current-free contacts for alarm signalling or working (thermal gap / air level loss / high rated startings). Wiring diagram MAIN SWITCH WAYS TO CONNECT THE MOTOR CONTACTOR CONTACTOR CONTACTOR AIR BREAK PUMPS ALARM (Only in Mod. V2P) SINGLE-PH REMOTE. PRES. 1 PRES. 2 THREE-PHASE MAINS SUPPLY INPUT (230-400 VAC) MOTOR THREE-PHASE MOTOR SINGLE- PHASE WITH EXTERNAL CAPACITOR MOTOR SINGLE- PHASE WITH BUILT-IN CAPACITOR FLOAT SWITCH All the input signal contacts are current-free, and activates the pump when turn on. Sheet 5

System Operation REMOTE CONTROL (EJ. TIMER, PROGRAMMER, ETC.) SENSOR REMOTE CONTROL (EJ. TIMER, PROGRAMMER, ETC.) UP TO 6 KM. CABLE 2x1,5 UP TO 6 KM. CABLE 2x1,5 PRESS 1 (Main) PRESS 2 (Secundary) 4 mm. fl exible pipe Recommended to do the pressure tap in the top of the hydropneumatic tank. HIGH LEVEL PROBE LOW LEVEL PROBE HIGH LEVEL PROBE LOW LEVEL PROBE OPERATION WITH PRESSURE SWITCHES. (MOD. V2P). P1: High level pressure switch. When closed, it starts only one pump. P2: Low level pressure switch. When closed, it starts the second pump. In case of failure of P1 pressure switch, it starts both pumps anyway, with a delay between them. OPERATION WITH PRESSURE LEVEL. (MOD. V2T). STARTING: If pressure drops 10% under set point, it starts the maintenance pump with 1 second delay. If pressure remains at 10% under set point, it starts the support pump 5 seconds after. STOP: If pressure exceeds 10% over set point, it stops the support pump with 1 second delay. If pressure remains 10% over set point, it stops the maintenance pump 7 seconds after. OPERATION WITH AUXILIARY INPUTS. LEVEL: In case of level loss in suction mode, both pumps stop automatically. Once level is recovered, the fi rst pump starts with 1 second delay and the second one 5 seconds after. REMOTE: If remote circuit opens, both pumps stop likewise, they both starting successively when circuit closes. SUPPLY: When powered, there is a stepped starting too of both pumps, if pressure demands it. Sheet 6

LEVEL PROBES START-UP. The lower level probe should be installed some centimetres over the pump suction level. The upper level probe should be located depending on well level and volume, at an appropriate height for an optimum use of well fl ow. It is essential for a good performance of the level control that ground connection is correct. If this is not possible, a third probe should be connected to the ground terminal block and located in well bottom. Pump (1 or 2) starts when the maximum level is reached and stops when drops to the minimum level, if pressure requests it. Important: If level probes are not to be used, maximum and ground terminal blocks must be linked. PUMP THERMAL PROTECTION. In case of overload in any of the pumps, or phase failure, there will be a thermal trip of the pump 7 seconds after anomaly detection. During these 7 seconds, alarm pilot light is fl ashing. AUTOMATIC RESET SWITCH. Located on the back side of the unit front cover, it has two positions: A POSITION (RESET ON): In case of thermal failure trip happened after the fi rst minute of pump running, the pump turns to reset alarm mode. In this case, the pump alarm pilot light remains switched on, but turns off for an instant (0.5 seconds) every 4 seconds. In 15 minutes, the pump will be automatically reset. B POSITION (RESET OFF): In case of thermal failure trip, reset is only available manually, pushing the reset button. PUMP ALTERNATION DUE TO ALARM. In case of maintenance pump thermal failure, the second pump substitutes it. ALARM OUTPUT (ALARM). Alarm output closes contact 6 seconds after level loss failure, or thermal failure in any of the pumps. Once level is restored or alarms reset, this output is disconnected after 2 seconds delay. AIR BREAK ALARM (AIR). This alarm is activated if the maintenance pump tries to re-start within an interval lower than 2 minutes. The output is activated only while the maintenance pump is running. If the start intervals reach 3 minutes, this alarm will be automatically disconnected. Pressing the reset button deactivates the air break alarm too. PUMP JAMMING PREVENTION. To prevent pump jamming (long resting periods), the unit activates it for 1 second every 23 hours of inactivity (only in AUTO mode). Sheet 7

System adjustment The adjustment is possible only if the motor is connected to the unit, otherwise, the low current alarm will be activated. Also, pump adjustment should be made in 0 position, otherwise the second pump is started due to overload in the fi rst pump. Light ON Light FLICKS OFF Maximum Current Adjustment 1.- Turn right to the limit Turn right Start motor. Green. (inside the unit) (front side) Wait 1 minute 2.- Turn slowly to the left until red light fl icks. Turn left......red light flicks 3.- Then, turn slightly to the right until red light stops fl ickering (OFF). Turn right... If......pump stops and overload alarm trips (red light ON)......red lights off...then push RESET and turn a little more to the right. Warning: Adjustment to the maximum value (13A) cancels any protection. Sheet 8

VIGILEC DOBLE V2T Control by pressure internal transducer System Operation Once fit the set point pressure, the equipment will fix maximum and minimum levels, situated on 10 per cent upper and lower the set point. In this case, the unit will control the pumps to keep the pressure within this range. PRESSURE Booster SUPPORT Low water consumption High water consumption SUPPORT MAINTENANCE MAINTENANCE MAINTENANCE SUPPORT 4sec 5sec 7sec 5sec 5sec 7sec SET POINT t<7sec TIME Booster. When activating the equipment,there is a small starting delay of 4 seconds, with the purpose of avoiding the instantaneous starting of the pumps. As at the begining the pressure is below the minimum, it will start the maintenance pump. If in 7 seconds the pressure has not raised over the minimum level, it will take the support pump. When pressure goes up over the maximum level, the support pump will stop. If pressure stays 5 seconds over the maximum level, the maintenance pump will also stop. Sheet 9

VIGILEC DOBLE V2T Control by pressure internal transducer Low water consumption. If pressure falls below the minimum level, the maintenance pump starts. Once reached the maximum level, the maintenance pump stops. If before 7 seconds the pressure raises over the minimum, the support pump will not enter. High water consumption. When falling the pressure below the minimum level, the maintenance pump starts. If pressure stays below the minimum more than 7 seconds, the support pump will start. Once both pumps booster the pressure until the maximum level, support stops. As when stops support the pressure decreases, maintenance will not stop. Once again pressure goes down until the minimum level, the support pump will start again. If the pressure stays more than 5 seconds on the maximum, maintenance will stop. Sheet 10

Specifications Voltage 230 / 400 Vac (selec.) - 50/60 Hz Permissible voltage fl uctuations +10% - 15% Maximum current 12 Amp (for each pump) AC3 Overload adjustment 0-13 A (adjustable) Underload trigger <0,5 A Probe voltage/sensitivity 24 Vac / 9 Kohm Remote connection Contact or voltage 6 to 400 Vac/Vdc Pressure switch connection (Mod. V2P) 12 Vdc - 10 ma Set-point pressure adjustment (Mod. V2T) 2-9 Kg / cm² Differential (Mod. V2T) ±10 % Maximum pressure permissible (Mod. V2T) 40 Kg / cm² Accuracy (Mod. V2T) ±0,1 Kg / cm² Pressure tank connection (Mod. V2T) Flexible (ø4 mm) tube with racor Input connection (power supply) Direct to main switch Output connection (motor pump) Direct to contactor 4 mm² Mounting Clevis wall mounting Weight 3,5 Kg Protection -10 + 55 ºC Operating temperature range IP56 Troubleshooting Problem Cause Solution The equipment does not work and the voltage light is off even when the system is connected to a power source. The equipment works but the contactor do not. The motor alarm lights on (Light indicator C ). Level control do not running correctly. Selection voltage fuse is fused (fuse 0,1 A). Incorrect input connection (singlephase installation). Phase failure. Voltage selection fuse incorrectly positioned. Inside overcurrent adjustment very low or critical. Mains phase failure. Motor overload. Motor underload. High and low level probes, inverted. Ground connection incorrect. Probes or Remote wire cut.. Check and replace selection voltage fuse (5x20 / 0,1A). Connect correctly. Check phase state. Select the correct position according to the entry voltage. Check the overcurrent adjustment. Check the three phases. Check the pump (jammed impeller, over/under voltage conditions,overcharge, etc.). Check the pump (dry well, dead head, etc.). Place the probes in correct position. Check the ground connection. Check the ground connection.. Sheet 11

EC DECLARATION OF COMPLIANCE WITH THE LOW VOLTAGE & ELECTROMAGNETIC COMPATIBILITY DIRECTIVES. TOSCANO LINEA ELECTRONICA, S.L. declares that the equipment described in this manual complies with the provisions of the modified LOW VOL- TAGE directive (Directive DC 2004/108/CE) and with the modifi ed ELECTROMAGNETIC COMPATIBILITY directive (Directive DC 2006/95/CE) and with national legislation based upon them. It also complies with the provisions of the following European standards and draft standards: NF EN 60.439-1 / EN 50.081-1 / EN 50.082-2. TOSCANO LINEA ELECTRONICA, S.L. Autovía A-92, Km. 6,5-41500 - Alcalá de Guadaíra - SEVILLA - ESPAÑA Tfno. 34 954 999 900 - Fax. 34 95 425 93 60 / 70 www.toscano.es - info@toscano.es Custom Service +34 954 999 900 English interviwer ISO9001:2000 Certifi ed by Bureau Veritas