Part No EWP & FAN DIGITAL CONTROLLER INSTRUCTIONS

Similar documents
LCD EWP /FAN DIGITAL CONTROLLER Installation Instructions

ELECTRIC WATER PUMP (EWP ) & LCD EWP /FAN CONTROLLER INSTALLATION INSTRUCTIONS. EWP80, EWP115, EWP130, & EWP150 Combo Packs

ELECTRIC WATER PUMP (EWP ) KIT INSTALLATION INSTRUCTIONS

EWP 110 INSTALLATION INSTRUCTIONS

DAVIES, CRAIG PROPRIETARY LIMITED A.B.N A.C.N MELBOURNE AUSTRALIA

INSTALLATION INSTRUCTIONS

Digital Controller 12 volt only

Davies Craig THERMACTIC FANS 1

Max. Current. 3 V - 15 V DC 10 Amps. 20 V - 27 V DC 5.5 Amps. 3 V - 15 V DC 10 Amps. 20 V - 27 V DC 5,5 Amps. 3 V - 15 V DC 10 Amps

PLEASE READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO COMPLY MAY VOID DAVIES, CRAIG WARRANTY.

Electric Water Pump (EWP )

ELECTRIC FAN. As a primary cooling source electric fans provide:

Electric Water Pumps

Transmission Oil Coolers Ultra-Cool & Hydra-Cool

FAN-PWM-V3. Instructions

SAVE THESE INSTRUCTIONS

ENGINE COOLING FAN Toyota Celica ELECTRIC COOLING FAN RADIATOR COOLING FAN SYSTEM TEST ENGINE COOLING Toyota Engine Cooling Fans

Introduction. TyreGuard 400 Assembly. Unit Conversion DAVIES, CRAIG PTY LTD TYREGUARD

Optimized Idle Aftermarket Installation Kits On-Highway Truck Applications (P/N: )

SIGNET Temperature Transmitter

In This DIY We Will Show You How To Install Recon Backup Lamps (part # To Run On A Separate Switch & In Reverse.



AP500 FAULT FINDING NEW INSTALLATION

C.E. Niehoff & Co. C505, C527, C531, and C534 Alternators Troubleshooting Guide CAUTION. Testing Guidelines. Hazard Definitions WARNING

Information Booklet WW20072

UNISTEER Performance Products UNIVERSAL HOT ROD ELECTRA-STEER KIT

Signet Temperature Transmitter

Multi-colour LED Status Light - using it as a diagnostic tool:

PRODUCT INSTALLATION GUIDE

WirelessAIR Advanced Integrated Remote

INSTALLATION INSTRUCTIONS

UNIVERSAL ELECTRA-STEER FOR 2 COLUMN 220w Plain w Polished w Plain w Polished

INSTALLATION INSTRUCTIONS

C FORD F250 / F L POWERSTROKE DIESEL WITH AUTOMATIC TRANSMISSIONS ONLY

About this catalogue:

30140 F5 Dual Fan Controller

install guide OEM-CH(RS)-CH5-[FLRSCH5]-EN

VAM-HD Basic Installation

Body Electrical System

Modulating Furnace Information. Warning on Meter Setting - Read First!

Installation Instructions

Visit for more technical information & downloads

VC-30 / VC-40 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

Installation and Operating Instructions. MPPT Solar System Controller ISC3040

Installation and Operating Instructions. Solar System Controller ISC3030

Installation and Operating Instructions. Solar System Controller ISC3020

install guide DIR-CH(RS)-CH5-[AKX-CH5]-EN

PERFECT FIT IN-DASH HEAT/ COOL/ DEFROST FORD FAIRLANE & CROWN VICTORIA

VC-4820 Programmable DC-DC Converter with Battery Charger function USER'S MANUAL

K+R Performance Engineering, Inc.

AUTOMATIC AIR CONDITIONER > COMPONENT DIAGNOSIS > BLOWER MOTOR CONTROL SYSTEM > SYSTEM DESCRIPTION > SYSTEM DESCRIPTION

TurfDefender Electronic Leak Detector Kit Reelmaster 5000, 6000 and 5010 Series Traction Units

Revision THERMO TECHNOLOGIES. USDT 2001 Differential Controller. Installation and User s Guide

SAISBM V36W Installation Instructions

Do isolate the power supply from other high power systems such as Stereos and Alarms

CA-510a Installation Instructions

HA PRO INSTALLERʼS MANUAL. HA-008 v3. User s/installer s Manual

INSTALLATION INSTRUCTIONS

Ford Racing 4.6L 3V Crate Engine Control Pack

Off Road Only (ORO) LiteSPOTs 8 Light Kit

PLATINUM. Sport Haltech 13B Terminated Engine Harness QUICK START GUIDE

ME AGS Auto Gen Start Network System with Inverter and Remote for Coach Generators Operator s Manual

DX: Engine Coolant Temperature (ECT) Sensor

MULTIRACK GARNET. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. 688 Manual. Page 1. Printed in Canada

Water Heater Unit. Thermo Top C Additional Heater. Installation Instructions. FORD Connect. Gasoline and Diesel. not with automatic transmission

Power Distribution System User s Manual. Model: PDS-100

Control System. Part B, Section 1. This section covers the following unit configurations. Model Voltage 1, 2 Pump Piston (E, F, or G)

MULTIRACK. Optic / Thermistor Rack Control for Trucks MODEL 688S / 688D MANUAL. Printed in Canada

Installation Instructions

3 in 1 TRAIL CHARGER with LOCKOUT

CAUTION. Even Brakes with a black cable need second vehicle kit Even Brakes with a blue cable need second vehicle kit 98450

WOT Box Installation Instructions VW / Audi

ODYR-25-1 & SLX-25-1 rev. A VACUUM/BOOST PRESSURE, TEMP, and EGT GAUGE

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Model APS-25CH Installation Manual

Installation Manual for the Pantera Ignition Switch Bypass

All cores due 30 days after invoice date - no credit after 60 days.

OIL FIELD ELECTRIC ACTUATOR INSTRUCTION MANUAL SPECIAL APPLICATIONS ACTUATORS Q 6.0.1

CUSTOMER WIRING INSTRUCTIONS TO SUIT: BA-BF XR6 and XR8 Universal Auto or Manual Trans

Part #82064 Add-A-Stage EFI Nitrous System

A) 8 Pin Female. CUSTOMER WIRING INSTRUCTIONS TO SUIT : Ford EL Manual Universal Instructions

SB SWITCH CONTROL BOX

CARM INTERNATIONAL TOWING MODULES

ELITE 1000/1500 Dodge SRT QUICK START GUIDE HT

The Power Systems Industry Experts. Installation Instructions. PT100 Stationary Generator Monitoring System

SSV2BR INSTRUCTIONS INSTALLATION INSTRUCTIONS

Nero 6600H/6601H. Installation Guide. Commercial Vehicle Productivity and Security. Antenna Configuration

PLATINUM Sport Haltech GM LS1 / LS6 Terminated Engine Harness (HT045650) QUICK START GUIDE

Model APS-25N Installation Manual

EGT-100 Operations and Installation Manual

POWERTRAIN CONTROL MODULE (PCM) - NGC

MAGNETO REPLACEMENT. Pre-Unit Twin Cylinder Motorcycles. ELECTRONIC IGNITION SYSTEM For 4 Stroke. With 12 VOLT Electrics, POS/ NEG Ground

MR6F LED Windshield Lights

Wiring diagrams on page 29 are for reference only. For detailed vehicle wiring refer to Navistar documents.

SAFETY PRECAUTIONS SAFETY FIRST!... 1 ABOUT THE CODE READER CONTROLS AND INDICATORS... 3 DISPLAY FUNCTIONS... 4

SERIES 700/700E FACTORY KEYLESS UPGRADE INSTALLATION MANUAL

ROADMASTER, Inc NE 127th Ave. Vancouver, WA Fax roadmasterinc.com ROADMASTER, Inc.

PRODUCT INSTALLATION GUIDE

SECTION 12M - SUPPLEMENTAL RESTRAINT SYSTEM (VERSIONS 8.0 AND 8.1)

Transcription:

77 Taras Avenue P.O. Box 363 Altona North Vic 3025 Australia Phone: +61(0)3 9369 1234 Fax: +61(0)3 9369 3456 Email: info@daviescraig.com.au Web: www.daviescraig.com.au Part No. 8020 - EWP & FAN DIGITAL CTROLLER INSTRUCTIS FOR INSTALLATI OF DAVIES, CRAIG DIGITAL CTROLLER FOR USE WITH THE EWP (ELECTRIC WATER PUMP), OR ELECTRIC FAN AND EBP (ELECTRIC BOOSTER PUMP). Congratulations on your purchase of the Davies, Craig EWP & Fan Digital Controller, designed to regulate the operation of the EWP / EBP by varying the pump speed in response to the temperature of the engine and by switching your Thermatic Fan on and off. The Digital Controller works best with the removal of the engine thermostat. The Controller has a push-button on the control panel which adjusts the target temperature (set point). Generally, higher engine temperatures will give improved fuel efficiency and lower temperatures more power, but it is recommended that engine operational temperatures be checked with the manufacturer. In combination with a Davies, Craig Thermatic Fan, the temperature of the whole cooling system can be set to the temperature you want. The Digital Controller will run the EWP after ignition shutdown to eliminate heat soak, and cool down the engine evenly. This controller is only suitable for 12V negative earthed electrical systems. PLEASE READ THESE INSTRUCTI IN THEIR ENTIRETY BEFORE YOU START WORK KIT CTENTS: Refer Figure 1: Item No. Part Description Qty No. 1. 8120 EWP Digital Controller 1 Assembly 2. 8411 Wiring Harness 1 (Includes 10Amp Fuse) 3. 8414 Sensor Assembly 1 4. 0613 Self Tapping Screw 4 5. 0415 In-Line Adaptor 1 6. 8512 Hose Clamps 2 7. 0574 Ring Terminal 1 8 1 2 8. 8510 Rubber Sleeves 2 Not Shown Not Shown 8920 Installation Instructions 1 8921 Sensor Installation Instructions 1 7 6 5 4 3 Figure 1: EWP & Fan Digital Controller - Hardware components. P/NO: 8920 Page 1 of 8

INSTALLING THE EWP & FAN DIGITAL CTROLLER (Refer Figure 2 below) Do not begin the installation of the EWP & Fan Digital Controller prior to the EWP being installed. Refer to the EWP Installation Instructions for details. Note: Wiring provided with EWP kit not required when using the Digital Controller, but keeps the wiring for Pump bleeding purposes. 1. The Controller must be fitted inside the passenger compartment. Locate a hole in the firewall (approx. 20mm in diameter) where the harness wiring (including the sensor & pump T-connector ) will be able to pass through. If a spot of adequate size cannot be located, then as a last resort, wires can be cut and re-joined. 2. Pass the T-connector of the wiring harness though the firewall into the engine bay and connect to pump. 3. Pass the black sensor cable through the firewall and out to the thermostat housing. 4. Connect the wiring harness to the controller and mount the controller (using 2 of the screws provided) in an appropriate position, such as near the fuse box, so that there is access to the temperature adjustment button --- avoid mounting the controller where it may be exposed to direct sunlight. Ensure a good earth connection using the self-tapping screw provided. NOTE: The earth(ground) lead must be connected to a metal part of the body. 5. An additional screw is provided for mounting the Controller fuse holder where necessary. 6. Connect the red wire from the wiring harness to the battery positive using the ring terminal provided. Connect the green wire from the wiring harness to an ignition source the wires may be spliced then soldered if necessary. Ensure no wire is exposed, by insulating the join with electrical tape. 7. Mount Remote Test Light in a location, which will be visible. The Test Light may be fitted by inserting it through a 4.6mm drilled hole in a plastic area of the interior/dashboard, or simply with adhesive tape. The Remote Test Light has pin connections to assist installation. Heat shrink or insulation tape can be applied to these pin connections once the test light is mounted. This will ensure the connection points are insulated and secure. NOTE: In carrying out the wiring procedure, please bear in mind that it is advantageous to minimise voltage drop and this can be achieved by keeping the wiring as short as possible. REMOTE TEST LIGHT SENSOR TO BE INSTALLED IN THERMOSTAT HOUSING OR IN-LINE ADAPTOR EARTH (Ground) FUSE HOLDER T CNECTOR +VE IGNITI SOURCE Fan Relay See wiring diagram: fig.5, page 5 BATTERY PASSENGER COMPARTMENT FIREWALL ENGINE BAY Figure 2: Digital Controller Wiring Diagram. P/NO: 8920 Page 2 of 8

OUTPUT OUTPUT VOLTAGE VOLTAGE (V) (V) INSTALLING EWP & FAN DIGITAL CTROLLER SENSOR There are two installation methods available: a) IN-THERMOSTAT HOUSING METHOD (Refer to separate instruction sheet) b) IN-LINE ADAPTOR METHOD (Preferred - Refer to separate instruction sheet) BLEEDING THE COOLING SYSTEM 1. Fill the cooling system with appropriate coolant. 2. Disconnect the controller T connector from the pump. Using the wiring harness provided in the EWP kit, cut the blue and black wires close to the relay holder, discard the remainder and connect the T connector to the pump. Loosely connect the blue wire to the battery positive and the black to negative. With the radiator cap off, run for 5-10 minutes to ensure that there is no air trapped in the cooling system. Continue to fill with coolant as the air is removed from the system. Disconnect the wiring from the battery to the pump and discard. Re-connect the pump to the controller T connector. Re-fit the radiator cap before starting the engine. 3. Check hose clamps after a few hours operation of normal temperature and again after 20 hours running. Check for leaks. OPERATI CTROLLER ALGORITHM-PUMP OPERATI Figure 3 shows the typical operational curve of the pump. The SET POINT is the temperature at which full battery/system voltage is supplied to the pump. This can be set to any of the 5 SET POINTS available: 75ºC/165 F,80ºC/175 F,85ºC/185 F, 90ºC/195 F, 95ºC/205 F. CTROLLER OPERATI LED CHECK: Every time ignition is turned, all LED s will be on for 5 secs before returning to the normal operation mode. This feature allows for checking that all LED s are operational. Area A - Pump pulsing at 6V: 10sec, 30sec Area B Pump pulsing at 6V: 10sec, 10sec Area C Pump voltage increases with increasing temperature, Fan begins the operation when the temperature reaches 3ºc/5.4 F above the set point 14 12 10 8 6 4 2 A B C 10 SEC, 30 SEC LINEAR RAMP FROM 6V TO SYSTEM VOLTAGE 10 SEC, 10 SEC 0 AMBIENT 60 65 70 C -20 75-15 80-10 85-5 90 TARGET 95 100 F 36 27 18 9 (SET POINT) COOLANT. RELATIVE TO TARGET ( C) Figure 3: EWP Operation Curve. F A N O N DIAGNOSTICS: To avoid any premature diagnostic indication during temporary events especially where the engine is for very short periods, the diagnostic functions will be activated 2 minutes after ignition is switched. OVER-RUN MODE: To eliminate heat-soak after ignition shutdown, the Controller will continue to run the EWP for 2 minutes or until the temperature has reduced to 5 C/9 F below set-point whichever occurs first. The Over-Run feature will eliminate heat soak but will be more effective when used in conjunction with a Thermatic Fan. P/NO: 8920 Page 3 of 8

Figure 4: Controller Operation EWP LED LED DISPLAY: The following identifies each LED and its operational status: LED (GREEN): ING 75ºC/165 F LED = Sensor temperature is below 75ºC/165 F. = ACTUAL sensor temperature. PWR LED (AMBER): = The controller has power. EWP LED (GREEN): ING = EWP operating in pulsing mode Refer Figure 5, areas A & B. = Electric Water Pump (EWP ) running between 6V Battery Voltage: Refer Figure 5, area. C FAN LED (GREEN): = Fan operating TEST LED (RED): = System warning has been triggered. Therefore, refer to Diagnostic Chart in order to determine possible Cause, and take measures to correct the problem. REMOTE TEST LIGHT (RED): This light will flash whenever the TEST LED is on. The purpose of this light is to provide remote indication when the TEST LED has been activated. OVER-RUN MODE: During Over-Run mode: - Actual sensor temperature will be indicated by GREEN temperature LED. - PWR LED will flash - EWP LED will be solid and pump will run at full battery voltage. - FAN LED will be solid and Fan will run until temperature below the target temp. P/NO: 8920 Page 4 of 8

SETTING THE EWP & FAN DIGITAL CTROLLER The Digital Controller can be set in accordance with your requirements. The factory set-point on the controller is 85 C/185 F. This setting can be changed by using the set-point adjustment button on the control panel as follows: i. Pushing the SET button once will indicate the present setting with an amber LED. ii. iii. iv. When SET button is held down, the set-point settings will be scrolled through. Button should be released when desired set-point is reached. The LED will then flash and the setting must be confirmed ( locked in ) by holding button down for 2 sec. If setting is not confirmed within 5 sec, controller will revert to previous setting. To check SET point, see (i) above. It is recommended that initially the set-point be set to approximately the mechanical thermostat opening temperature. Use a lower set-point to run the engine colder or a higher set-point to run the engine hotter. Generally, running the engine slightly colder will increase the power and running the engine slightly hotter will improve the fuel efficiency. To verify SET temperature, run the engine and monitor existing engine temperature gauge. CTROLLER INSTRUCTIS For your convenience, brief operating instructions are available on the reverse side of the controller. Davies Craig Thermatic FanWiring to the Digital Controller Please follow the below instructions 1&2 if you are using the wiring loom provided with Davies Craig Thermatic Fan. 1. Cut the green wire from the Fan wiring loom to a sufficient length, this wire (with relay) to be joined with the black traced green wire from the Digital Controller 2. Cut the black wire before the ring terminals attached, and then join sufficient length of wire to connect the battery positive as shown in the diagram below (85). Please discard the ring terminal part. (-ve) Fan Motor 86 30 Relay Relay 87 Blue Red Battery +ve 85 Black CNECT THE BLACK WIRE FROM 85 TO BATTERY +VE. Figure 5: Fan to Controller wiring diagram P/NO: 8920 Page 5 of 8

CTROLLER FOR FAN LY CNECTI The Davies, Craig Digital Controller is programmed to earth the electric fan relay at 3 C above the target set point. The Controller will run the fan until the coolant temperature is below the target point. To enable fan only control without using an Electric Water Pump, connect the supplied remote LED to the controller wires labelled PUMP as shown below Pump Connector A 12V LED connected to the Pump connector Please refer to the figure 5 for fan to controller wiring details. Please call Davies, Craig at (03)93691234 if you required another remote LED to complete the wiring. EWP& FAN DIGITAL CTROLLER TECHNICAL SPECIFICATI Input Voltage Output Voltage Max. Current Operating Temperature 12VDC to 15VDC 6V to 15V 12A -20ºC to 60ºC (-4ºF to 140ºF) Setting Temperatures 75º, 80º, 85º, 90º, 95ºC Fan Cut in Temperature Sensor Type Time Out Weight Dimensions (165º, 175º, 185º, 195º, 205ºF) 3ºC/5.4 F above the set temperature Thermistor in waterproof housing 2 Min. (or Set 5ºC/9 F) after ignition 90 grams (3.2 oz.) Figure 6: Closing the pump loop 101mm (L) X 95mm (W) X 35mm (D) [4 (L) X 3-3/4 (W) X 1-3/8 (D)] These installation instructions will suit most situations. However, many conditions of engine design, environment and driving conditions or styles may call for other configurations not described here. Advice is available from Davies, Craig and we would very much appreciate your feedback. INSTALLATI RECOMMENDATIS For improved heater performance on vehicles which have the heater inlet (return) and outlet ports in the mechanical pump housing, Davies, Craig has developed the Electric Booster Pump, EBP, which fits into the heater hose and boosts flow through the heater circuit and/or cylinder heads. There is more information on our web page www.daviescraig.com.au LPG (Liquid Petroleum Gas) vehicles require constant flow through the LPG converter and if the EWP is used in conjunction with the Digital Controller, we recommend the installation of an EBP (Electric Booster Pump) to overcome freezing of the converter body at start up. P/NO: 8920 Page 6 of 8

TABLE 1: COOLING SYSTEM DIAGNOSTIC CHART The following table lists the Digital EWP & Fan Controller diagnostic capability for your cooling system and the LED diagnosis sequence. NOTE: In all instances where the TEST light is, the EWP is running at full battery voltage. 1 2 3 4 5 6 7 8 9 10 Blown Fuse: Controller does not operate. Low Voltage: Battery Voltage < 11V. High Voltage: Battery Voltage > 15.0V CDITI Sensor Read Error 1: Open-circuit on sensor lead or thermistor. Sensor Read Error 2: Short-circuit of sensor leads. Low Operating Temp Fault: Sensor Temp < 30ºC/86 F after two minutes. Over-Temperature: Sensor Temperature is at least 10ºC/18 F above SET point. Set-Point Error: SET point value stored is invalid. Pump Connection Error: Open circuit on pump leads or pump leads not connected. Microprocessor Error: Controller Programme Invalid. TEST PWR LED SEQUENCE TROUBLESHOOTING Check fuse or connection. Check battery, alternator and/or regulator. Check battery or regulator. Check sensor wiring. Check sensor wiring. Check engine temperature. Check sensor installation or cooling system. e.g. Fans Re-set-; if this fails contact Davies, Craig. Check pump wiring and operation. Contact Davies, Craig. NOTE: When a temperature related error has occurred, this may not necessarily be associated with the pump but could be associated with the overall cooling system. e.g Fans, fan thermal switch, coolant level. Therefore, inspection should not be limited to the pump alone in trying to isolate the cause EWP (75º/C165 F) (80ºC/175 F) (85ºC/185 F) (90ºC/195 F) PLEASE RETAIN THESE INSTRUCTIS FOR FUTURE REFERENCE (95ºC/205 F) P/NO: 8920 Page 7 of 8

CAUTIS Engine temperature must be monitored closely at all times but especially immediately after installation and until pump operation and capacity have been proved. Do not use the vehicle s engine management system or wiring connected to the vehicle s engine management system as an ignition source because it may cause failure of the management system and/or the electrical system. The ignition source must be a steady positive supply of 12-14VDC. WARRANTY We warrant that for a period of two years from the date of purchase, we shall carry out, free of cost, any repairs that are reasonably necessary to correct any fault in the operation of your Electric Water Pump provided that such a fault is directly attributable to a defect in the workmanship or materials used in the manufacture of the part(s) and is not due to installation other than described in these instructions. Labour and consequential costs are excluded DAVIES, CRAIG PTY. LTD. REGISTER YOUR WARRANTY AT: http://www.daviescraig.com.au/warranty-content.aspx P/NO: 8920 Page 8 of 8