Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

Similar documents
General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

Requires Ductwork and Blower

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

V05 General Purpose Bench Fume Hood

Supreme Air Fume Hood Option Availability

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

Protector XStream Laboratory Hoods

Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

LABORATORY FUME HOODS OF 5

F. VAV hoods shall have a restricted bypass plate.

SECTION LABORATORY FUME HOODS

Fume Hoods Overview OVERVIEW

FUME HOOD SELECTION GUIDE

PERCHLORIC ACID FUME HOOD H25. Fume Hoods. 48"- 60"- 72"- 96" long

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

Laboratory Fume Hoods & Enclosures

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

Accessories Standard Service Fixture Kits

CORPORATION DURALAB CORPORA

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

LABORATORY FUME HOODS

Bedcolab Vanguard Laboratory Fume Hoods

Pre-Wired and Pre-Piped

Laboratory Fume Hoods & Enclosures

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

How to Use a Chemical Fume Hood Safely

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Ventilated Balance Enclosures

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

Protector Demonstration Hoods

new fume hoods providing performance and protection

Lab Safety & Energy Optimization. Introduction & Agenda

LABORATORY FUME HOODS

Model ND-2 Specification

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

HEMCO. Laboratory Fume HoodsR

Design Requirements The system shall be designed, manufactured, tested and installed in compliance with the current versions or issuance of:

Products & Capabilities

Supreme Air Series VENTURI FUME HOOD. Operation Maintenance Technical Manual KEWAUNEE

Polypropylene Total Exhaust Fume Hoods

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

KEWAUNEE encouraging new discovery

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Fume Hood Operation & Maintenance Manual

Labconco 48, 60, and 72 Hoods

Centrifugal Filtered Supply Roof Blowers

Completing Your Fume Removal System

AUDIO-VISUAL EQUIPMENT

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

Protector Echo Filtered Fume Hoods

LABORATORY CABINETRY AND SPECIALTIES: FUME HOODS

Thermo Scientific Hamilton Air Flow Products. Table of Contents

DIAGNOSTIC TESTING USING ASHRAE 110. Gerhard Knutson, Ph.D., CIH Knutson Ventilation, Inc

Protector Airo Filtered Fume Hoods

3.5 Exposure Control Measures

Square Inline Fans with Multi-Directional Discharge

Inline and Roof Mounted Fans

Modified Downdraft Paint Booth Nut and Bolt Assembly Pre-Punched Panel Flanges

KVR Capture Jet. KVR- Capture Jet Round Island Hood with Perimeter Jets. Round Island Hood with Perimeter Jets

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

AUDIO-VISUAL EQUIPMENT

.3 Section Vibration Isolation and Seismic Control..2 ANSI/AMCA 210/ASHRAE 51 Laboratory Methods of Testing Fans for Rating.

Industry best 5 year fan housing warranty, 1 year motor warranty

User s Manual. LabShield. Laboratory Fume Hoods. Air Foil By-Pass Models: 6714, 6716, ADA Models: 8796, 8798, Demonstration Hood 6725G

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

W-VI Series - Internal Make-up Air Wall Canopy

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

SECTION METAL LOCKERS. A. ADAAG Americans with Disabilities Act, Accessibility Guidelines.

Protector Controlled Atmosphere Glove Boxes

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures

Refrigerators/Freezers

Direct Gas-Fired Heating

ADVANCED SAFETY ENGINEERING FOR EFFECTIVE HANDLING OF HAZARDOUS PARTICULATE DRUGS AND POWDERS IN A CLASS II, TYPE A2 BIOLOGICAL SAFETY CABINET

SECTION ISOLATOR SERIES LABORATORY FUME HOODS

SECTION AXIAL HVAC FANS

Tube Axial Inline Fans

MODEL TUB TUBEAXIAL UPBLAST PROPELLER ROOF EXHAUSTER

LABGARD FEATURES

MODEL TXD DIRECT DRIVE CENTRIFUGAL UPBLAST ROOF EXHAUSTER

Series 301. Horizontal Laminar Flow Clean Bench. C l e a n B e n c h e s. s o l u t i o n s. Series 301 Horizontal Laminar Flow Clean Bench

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

Quiet-Duct Conic-Flow Silencers Section Specifications

Complete HVAC Capability

PennBarry Fan Guide Specification. Laboratory Exhaust System: Model vplume

Tube Axial Fan Page Specifications & Dimension Data Performance Data

Centrifugal Roof Supply Fans Models RSF and RSFP. Forward Curved

B. Base occupied space sound level estimates on ARI 885. C. Terminal heating coils shall conform to ARI 410.

CENTRIFUGAL UPBLAST ROOF EXHAUSTERS Model VRBK

Transcription:

Supreme AirLV- LOW CONSTANT VOLUME FUME HOODS KEWAUNEE encouraging new discovery

Supreme Air LV Fume Hood Low Velocity Low Volume Full Access

Hold-Open Catch for set-up sash position Flush Mounted Convergent Airflow Airfoil Cord access through sash handle Stainless steel cable reinforced nylon sash belt and sprocket Optional Air Alert 600 airflow alarm Safe, Energy Efficient Design Patent pending, self-closing sash to 1 for less exhaust volume and maximum protection. Patented Dynamic Barrier bypass provides safe flow of clean air between experiment and user. Unique interstitial, vertical slot baffles for exceptional turbulence free airflow and minimal upper vortex roll. Spoiler shaped sash handle directs air away from user. User Friendly Design Flush sill airfoil allows obstruction free access to fume hood. 35 1 /2" high safety glass sash for optimal unobstructed sight into fume hood. Stainless steel cable reinforced, notched nylon belt and aluminum sprocket sash counterweight system for level, smooth, quiet sash operation. 2 sash opening with automatic hold-open latch for easy loading and unloading of hood. Rear baffles removable for easy cleaning and hood maintenance. Triangular shaped access panels with staggered service outlets for easy set-up and maintenance. Unique rear outleted anti-splash cupsink mounts at front of hood worksurface without interfering with cabinet storage below. Notched sash handle for neat and easy cord and hose management. Available with recommended Air Alert 600 airflow alarm with digital readout, visual and audible alarms, and onboard data logging. Tested Safe at all Sash Positions Supreme Air LV fume hoods have been tested using the ANSI/ASHRAE 110-1995 procedure to verify compliance with ANSI/AIHA Z9.5-2003. In addition the hoods have been tested using severe dynamic challenges (including the walk-by simulation apparatus of EN 14175) to confirm their superior containment capability. Unique Interstitial Vertical Slot Baffles, easily removed for cleaning and maintenance. Unique triangular gasketed access panel and staggered service outlets for improved hose management Unique rear outlet, anti-splash cupsink mounts at front of hood without intruding on under-hood storage space

Turbulent Free Airflow for Superior Containment at All Sash Positions Self-closing sash to 1 above worksurface, flush sill airfoil, unique baffle configuration, and 35 1 /2" high unobstructed view into hood for ultimate safety, unsurpassed comfort, and improved exhaust air savings. Sash at Set-up Position Sash latched fully open with full containment at face velocities as low as 55 fpm. Dynamic Barrier Upper Bypass for safe contaminate-free air behind sash with minimal upper vortex roll. Vertical Interstitial Baffle Slots for improved linear airflow though face opening. Sash at Working Postion Hold-open latch released. Sash automatically closes to working position Convergent Airflow Airfoil flush mounted for easy access provides sweeping airflow across the worksurface. Sash Fully Closed Full 35 1 /2" high viewing area

Supreme Air LV Fume Hood Low Constant Volume Vertical Rising Sash 4'-0" 5'-0" 6'-0" 7'-0" 8'-0" LV05 543448-00 LV05 543460-00 LV05 543472-00 LV05 543484-00 LV05 543496-00 Liner Options: K = KMER Kewaunee Modified Epoxy Resin G = Kemglass Fiberglass reinforced polyester S = Type 304 Stainless Steel The blank left in the fume hood catalog numbers is for designating the desired lining. Example: LV05K543448-00 would designate a 4' hood with a KMER lining. DIMENSIONS HEIGHT LENGTH DEPTH Overall Dimension 89 3 /4" * 4 60" 72" 84" 96" 36 1 /4" Work Top 37" * 39" 51" 63" 75" 87" 24" Clearance (sash up) 103" *............... * Subtract 1" in height if wood base cabinets are used. Overall Hood Length Airflow Requirements 55 FPM at 2 Sash Opening 84 FPM at 1 Sash Opening Sash Height Opening Sq. Ft. * * Includes free area contributions from sash clearance spaces and bypass opening. Static pressures shown are for the pressure drop through the hoods only. The total pressure drop through the hood and the duct system must be calculated to select the proper exhaust fan. Accessories Include: Two 120 volt AC 20 amp GFI receptacles, single-tube, T-5 fluorescent light fixture with 20 amp light switch. No wiring for the electrical fixtures is included unless H-Option is added to part number. Hoods with H-Option are UL listed. Optional Accessories: Each front post and interior end liner is punched for up to five (5) remote control service fittings. Service fittings, fan, fan switch, work top, cupsink, and base units must be ordered separately. CFM Static Pressure 66 FPM at 2 Sash Opening 100 FPM at 1 Sash Opening Sash Height Opening Sq. Ft. * CFM Static Pressure 4'-0" / 4 2 7.85 432.15 1 5.15 515.20 5'-0" / 60" 2 10.27 565.15 1 6.73 673.20 6'-0" / 72" 2 12.69 698.20 1 8.31 831.25 7'-0" / 84" 2 15.10 831.10 1 9.90 990.15 8'-0" / 96" 2 17.52 964.15 1 11.49 1148.20 Add On Options: Rough-In for 4' 5' 6' Hoods Vertical Section Electric & Plumbing Options: G = Front Load Fixtures H = Pre-Wired to Top of Hood UL Listed Interior Lighting Options: K = Vapor Proof Light L = Explosion Proof Light Sash Options: 3 = Tempered Glass Sashes Other Options: D = Distillation Rack E = Fire Extinguisher M = Air Alert 600 Alarm O = St. Steel Airfoil 6 = Tissue Screen 7 = St. Steel Duct Collar To specify option, add option letter or number to the end of the part number. Example: LV50K543448-00H. 1" 1" Pipe Space Below Work Top Plumbing Access (both sides) EQ EQ 2" 10" 11 15/ 16 " O.D. Exhaust Collar 4 60" 72" 10" 7/" 1 2 1 4 " Rough-In for 7' 8' Hoods 363/ 4 " Pipe Space Below Work Top Plumbing Access (both sides) 21" 24" 42" 4 21" 24" 2" 7/" 1 2 1115/ 16 " O.D. Exhaust Collars 84" 96" 1 4 " 363/ 4 " 103" Clearance Sash Up 89/" 3 4 54" 17/" 1 4 35/" 1 2 2 Opening 1/" 1 4 5" 41/ 5" 363/ 4 " 24" 35/" 3 4 " 1 2 22" 341/ 1/" 1 2 85"

Section 11610 Supreme Air LV Fume Hood (abbreviated) 1.01 SUMMARY AND SCOPE Based on Kewaunee Scientific Corporation's Supreme Air LV Series fume hood design, furnish and install all fume hoods, work tops, and understructures. Furnishing and installing all filler panels, knee space panels and scribes as shown on drawings. 1.02 REQUIREMENTS Fume hoods shall be of LV aerodynamic entry design to insure maximum operating efficiency. Sash and air entry framework of the hood shall minimize eddying of air currents at low velocities and vertical slot rear baffle system shall minimize turbulence in all portions of the hood interior. 1.03 SUBMITTALS The fume hood shall be factory tested per ANSI/ASHRAE 110-1995. Provide certification that the fume hood meets ANSI Z9.5 criterion of AM 0.05ppm plus SME maximum not to exceed 0.05ppm. 2.01 MANUFACTURER The basis of this specification is the Supreme Air LV fume hood as manufactured by Kewaunee Scientific Corporation, 2700 West Front Street, Statesville, North Carolina. 2.02 MATERIALS AND CONSTRUCTION A. Fume Hood Frame: Steel angle rigid frame construction for independent support of interior and exterior components. B. Side Walls: Double wall ends, maximum 4.5" wide, with interior end panels and sash track flush with the facia. C. Airfoil: Flush convergent z-cross section airfoil mounted to the worktop, 12 gauge painted steel. (Optional: stainless steel.) D. Duct Collar: 12" diameter polyethylene bell-mouthed duct collar. E. Lighting: Single-tube T-5 fluorescent light fixture. F. Vertical Sash: Frameless vertical sash of 1 /4" laminated safety glass with 2 opening and 35 1 /2" interior viewing height. G. Sash System: Vertical opening of 1 programmed into toothed belt-drive sash system such that openings greater than 1 will gently and precisely return to 1 when sash released. Sash lockout at 2 for set-ups. Stainless steel cable reinforced notched belt-drive counterweight system. H. Baffle system: Interstitial vertical slots and lower horizontal slot. Back baffle panels shall be easily removable. I. Fume Hood Electrical Services: The hood superstructure shall be pre-wired and be UL listed. Electrical services shall consist of two 20 amp, 120 volt AC, GFI duplex receptacles and a 20 amp light switch. Cover plates shall be stainless steel. J. Hood Worksurface: Epoxy resin hood worksurface shall be 1 1 /4" thick molded epoxy resin made in the form of a watertight pan, not less than 3 / deep to contain spillage with a 6" wide safety ledge across the front edge. The worksurface and cupsink shall be available in either black or grey. K. Cupsink: Anti-splash design, 3 1 /2" x 5 1 /2 oval, with horizontal rear outlet not extending more than 7" below worksurface. L. Service Fittings: (Choose one) 1. Front Mounted Remote Control Fittings: Service fitting valves shall be mounted on the facia with the working components of the valve accessible from the hood exterior. Valves shall be furnished with 2 1 /4" diameter, 2" high, round handles with color-coded index buttons and color-coded service outlets. 2. Rod Type Remote Control Fittings: Service fitting valves shall be mounted to the hood side liners with extension rods to the front facia. Valves shall be furnished with black four-arm handles with color-coded index buttons and color-coded service outlets. M. Access Opening: The interior end liner panels shall be furnished with a triangular gasketed opening that provides access to the service piping and valves to facilitate installation and maintenance. Valve outlets shall be mounted on a line parallel to the rearward-facing angled edge of the access panel. N. Fume Hood Finish: After the metal component parts have been completely welded together and before finishing, they shall be given a five-stage metal preparation water treatment consisting of: a caustic rinse, a water rinse, iron phosphate treatment, a water rinse, and a deionized water rinse. After this treatment, the metal shall be dried at 325 degrees Fahrenheit. The steel surfaces shall be coated with a corrosion-resistant powder coat finish 0.0023" inches thick which shall then be fused in an oven at a temperature of 375 degrees Fahrenheit for 20 minutes. Any liquid-based paint system is unacceptable due to VOC's and other environmental issues. O. Fume Hood Liners: (Choose one) 1. KMER Epoxy Resin Lining: Interior liner panels shall be 1 /4" thick epoxy resin sheets of a white color. Interior liner panels shall be fastened using stainless steel screws with plastic covered heads. Flame spread of material as measured by ASTM E84 shall be 6.2 or less. Fiberglass reinforced plastics or polyesters shall not be acceptable substitute liner material for epoxy resin. 2. Stainless Steel Lining: Interior liner panels shall be 16 gauge Type 304 stainless steel with a No. 4 finish. Interior liner panels shall be fastened using stainless steel screws. 3. Kemglass Reinforced Polyester Lining: Interior liner panels shall be 1 /4" thick fiberglass reinforced polyester sheet. Panels shall be fastened using stainless steel screws with plastic covered heads. P. Fume Hood Bypass System: All bypass air shall pass through a front-to-back unperforated dynamic barrier bypass. Laboratory air shall always be the source of bypass air. Q. Digital Face Velocity Alarm System: (Optional) Fume hoods shall be provided with an alarm system to detect low hood face velocities. The system shall have an air velocity sensor mounted on the interior side liner of the hood connected to a perforated averaging tube running across the entire front interior of the hood. The velocity monitor shall have a digital display indicating the actual the air velocity through the hood face in feet per minute. The alarm signals shall activate any time the face velocity falls below the low velocity alarm set point or rises above the high velocity alarm set point. There shall be both visual and audible alarm signals. The audible alarm shall have a mute. Low alarm contacts shall be provided for remote monitoring. A scroll-type recorded read-out of alarm events for the past 60 minutes will also be displayed. Supreme Air LV fume hoods are covered by one or more of the following United States and Canadian patents: 4,856,420 1,275,847 5,241,788 Des. 346,437 5,407,389 5,718,626 5,797,790 6,290,202 B1 6,350,194 B1 6,450,875 B1 2,192,879 5,447,468 5,582,472 Des. 388,986 5,951,133 5,994,644 6,047,838 6,112,913 6,113,199 6,301,837 B1 For full specifications, visit Kewaunee s web site. KEWAUNEE ScientificCorporation P.O. Box 1842 Statesville, NC 28687-1842 Phone: (704) 873-7202 Fax: (800) 932-3296 E-mail: marketing@kewaunee.com Web Site: www.kewaunee.com LVFHB-03/04 Copyright 2004 Printed in U.S.A. 03/04