Supreme Air Fume Hood Option Availability

Similar documents
Supreme Air Venturi KEWAUNEE. Laboratory Fume Hoods. encouraging new discovery...worldwide

Supreme Air Venturi Laboratory Fume Hood Catalog. ehpricesales.com

General Purpose Walk-In Fume Hood

General Purpose Walk-In Fume Hood

Pre-Wired and Pre-Piped

V05 General Purpose Bench Fume Hood

Supreme AirLV- FUME HOODS. KEWAUNEE encouraging new discovery LOW CONSTANT VOLUME

Supreme Air. Fume Hoods KEWAUNEE LABORATORY. encouraging new discovery

Accessories Standard Service Fixture Kits

Laboratory Demonstration Space Located at Price Research Center North Winnipeg. Fume Hoods. ehpricesales.com

Protector XStream Laboratory Hoods

Fume hood construction details. VANGUARD FUME HOODS Listed by Intertek to UL 1805 standard page 1. Features

Fume hood construction details VANGUARD FUME HOODS. Listed by Intertek to UL 1805 standard. page 1. Features

Fume Hoods Overview OVERVIEW

Protector Special Application Hoods Laboratory Hoods for Radioisotope, Perchloric Acid and Acid Digestion Use Fiberglass 28, Demonstration and Canopy

Protector XL Floor-Mounted Laboratory Hoods Features & Benefits

FUME HOOD SELECTION GUIDE

SECTION LABORATORY FUME HOODS UNIFLOW LE SERIES

Requires Ductwork and Blower

Laboratory Fume Hoods & Enclosures

Supreme Air Series VENTURI FUME HOOD. Operation Maintenance Technical Manual KEWAUNEE

F. VAV hoods shall have a restricted bypass plate.

.1 Special Building Areas 8. Laboratories..3 Laboratory Casework (section ).4 Chemical storage cabinets (section )

Protector XStream Laboratory Hood is shown with SpillStopper Work Surface , Protector Acid Storage Cabinet and Protector

LABORATORY FUME HOODS OF 5

Direct Gas-Fired Heating

PERCHLORIC ACID FUME HOOD H25. Fume Hoods. 48"- 60"- 72"- 96" long

LABORATORY FUME HOODS

Purifier Logic Class II Biosafety Cabinets FEATURES & BENEFITS

FVC2100/2200 TEK-AIR TECHNICAL PRODUCT DATA SHEET FUME HOOD FACE VELOCITY MONITOR AND CONTROLLER. Application. General Description

Application. Tek-Air Systems, Inc. 41 Eagle Road Danbury, CT (203) FAX: (203) SALES FAX: (203)

SECTION LABORATORY FUME HOODS

BMC. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION M E M B E R

RDM. Laboratory Fume Hoods SEFA SCIENTIFIC EQUIPMENT & FURNITURE ASSOCIATION

Bedcolab Vanguard Laboratory Fume Hoods

new fume hoods providing performance and protection

How to Use a Chemical Fume Hood Safely

Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Alpha System ADAPTABLE KEWAUNEE LABORATORY FURNITURE. encouraging new discovery

Annexure-1. Annexure- 1 TECHNICAL SPECIFICATIONS FOR THE MODULAR LABORATORY FURNITURE (CNSNT/RL-4)

Ventilated Balance Enclosures

Section Fume Hoods Specifications 6/1/14 LABORATORY FUME HOODS

Labconco 48, 60, and 72 Hoods

CORPORATION DURALAB CORPORA

FUME HOOD. Installation and Operations Manual

Clean Air Products Straight Thru Standard Profile Single Door Air Shower Purchase Specification

AUDIO-VISUAL EQUIPMENT

DetectAir KEWAUNEE FILTERED FUME HOODS. encouraging new discovery

LABORATORY FUME HOODS

January, 2014 Page 1 of 6

LABGARD FEATURES

SECTION WIRING DEVICES

3.5 Exposure Control Measures

A. Each cabinet must be constructed and installed in accordance with EN12469:2000.

Laboratory Fume Hoods & Enclosures

Fume Hood Operation & Maintenance Manual

Protector Demonstration Hoods

INSTALLATION MANUAL. Melink Corporation (513) Revision

PRECISION UK Ltd DUPLEX AGSS PLANT

AUDIO-VISUAL EQUIPMENT

SLIM LINE FUME HOOD MONITOR

HOOD ACCESSORIES HOOD ACCESSORIES HOOD ACCESSORIES

500-YH SINGLE DUCT AIR TERMINAL UNIT FORM EG1 (1101)

ANATOMY DISSECTION TABLES

.2 Section Waste Management and Disposal..5 Section Thermometers and Pressure Gauges Piping Systems.

AIR ZONE INTERNATIONAL MIXED-FLOW AIR COLUMN UNIT

DEPAUL UNIVERSITY. Fume Hoods Manual. Environmental Health & Safety. April 2017

Thermo Scientific Hamilton Air Flow Products. Table of Contents

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

DESIGN STANDARDS WASHINGTON UNIVERSITY SCHOOL OF MEDICINE

Explosion Proof Electric Fan/Blower - C1D1-1/3 HP Engine - Fan Only- 50' SOOW w/ EPP Cord Cap

Design Requirements The system shall be designed, manufactured, tested and installed in compliance with the current versions or issuance of:

Lab Safety & Energy Optimization. Introduction & Agenda

ZONE PRESENCE SENSOR FEATURES SPECIFICATIONS TABLE OF CONTENTS. VAV system using a Zone Presence Sensor.

100% OUTSIDE AIR MAKE-UP UNITS WITH DISCHARGE TEMPERATURE CONTROL & c.pco DIRECT DIGITAL CONTROL MODULE

ELVORON HOME ELEVATOR

th Avenue Spring Lake, MI Ph:

HORIZONTAL SLIDING DOORS

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

500-YVI PARALLEL FAN-POWERED AIR TERMINAL UNIT FORM EG3 (404)

SDL Single-Duct, Low-Height, VAV Terminals

HEPA AIR FILTRATION SYSTEM

PURCHASE SPECIFICATIONS FOR NUAIRE PHARMAGARD NU-NR797 NEGATIVE PRESSURE RECIRCULATING STERILE ISOLATOR

Quotations are invited for Fume Hoods for Chemistry Laboratory Pre Qualification Criteria

Fume Hood Program. Program originated: 08/2008 Updated: 06/2016. Gordon Krueger Environmental Safety Specialist

DESIGN GUIDELINES LOW VOLTAGE SWITCHGEAR PAGE 1 of 5

REDISHIP Biosafety Cabinets, Fume Hoods and Balance Enclosures

East Central College

SECTION HVAC POWER VENTILATORS

Protector. Storage Cabinets, Base Stands & Fume Hood Accessories

PROTECTOR FIBERGLASS ENCLOSURES

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

TSS Single-Duct VAV Terminals

500-YCI SERIES FAN-POWERED AIR TERMINAL UNIT FORM EG2 (404)

---:...-- Environmental Health & Safety RADIATION PROCEDURES MANUAL. Procedure Cover Sheet. Procedure Number: EHS REV 2

TXH TOTAL EXHAUST HOOD. Installation and Operations Manual

Design Standard - Fume Hoods & Fume Hood Exhausts

SINGLE DUCT TERMINAL UNITS

Refrigerators/Freezers

Submittal 30 [762] 36 [914] 40 [1016] 50 [1270] 60 [1524] 70 [1778]

Transcription:

Supreme Air Fume Hood Option Availability Options V05 V06 V07 V15 V16 V25 V26 Kemglass Liner ( 1 /4") G KMER Liner ( 1 /4") K Type 316L Stainless Steel Liner (16 ga) L Type 304L Stainless Steel Liner (16 ga) S Phenolic Resin Liner ( 1 /4") T Laminated Safety Glass Sash G1 Tempered Glass Sash G2 Rod Control Needle Valve Fittings F1 Rod Control Ball Valve Fittings F2 Front Load Fittings F3 Variable Air Volumn (VAV) V Air Alert 600 Alarm - Vertical Sash A1 Air Alert 600 Alarm - Combo/Horzontal Sash A2 Air Alert 300 Alarm A3 Sash Stop/Sash Open Safety Label L Distillation Rack - Preparation D Safety Shield S Tissue Screen T Specification Grade GFCI Receptacles S_ Hospital Grade GFCI Receptacles H_ Fan/Blower Switch - 1hp motor rated K Pre-Wired U Type 304L Stainless Steel Airfoil O Type 304L Stainless Steel Sash Pulls Q Type 316L Stainless Steel Duct Collar C Cord Port P1 Auto Sash Return R1 Auto Sash Operator R3 VFH-12/16-22

Supreme Air Fume Hood Options VAV Restricted Bypass - Option V Venturi fume hoods are designed for operation on variable air volume (VAV) exhaust systems when used with a fume hood face velocity controller (not provided with hood). On standard Venturi hoods, the size of the air by-pass provides sufficient area that, with 100 feet per minute by-pass velocity with the sash closed, the exhaust volume will be 25 CFM per square foot of internal hood worksurface. This by-pass size is not appropriate for all VAV applications due to functional differences in face velocity controllers and variations in room exhaust requirements. If a different by-pass size is required, it should be specified at the time the hood is ordered. Air Alert Fume Hood Monitor Option A1 & A2 ENTER + AIRFLO W M O NITO R SAFE ALARM - Air Alert 600 Fume Hood Monitor consists of a thermistor sensor mounted on the fume hood interior wall and connected to fume hood containment cavity by a sensor port. A tube to the fume hood fascia completes monitored air path. The monitor measures and records the fume hood face velocity and sounds an alarm when the airflow falls below safe levels. Green, amber, and red LEDs signal safe, marginal, and low face velocity conditions. Alarm and lights are augmented by a digital liquid crystal readout and a visual one-hour "Event Timeline" that records alarm occurrences and their length for a continually updated one-hour time interval. Mounted on the hood fascia, the control monitor also contains "enter", "+", and "-" buttons that offers the hood user a variety of alarm features. Alarm setpoints, metric or classical units, alarm delay intervals, nighttime setback, and muting options are all programmable. The Air Alert 600 operates on 9-30 volts AC or DC and comes complete with an adapter that can be plugged into any 120 VAC receptacle. KEW AUNEE AIR ALERT 600 Option A1 Air Alert 600 Vertical Sash Fume Hoods Option A2 Air Alert 600 Combination & Horizontal Sash Fume Hoods Air Alert Fume Hood Monitor Option A3 Air Alert 300 consists of a thermistor sensor mounted through the end wall of the hood, and a control monitor that gives both a visual and audible alarm. The alarm monitors the fume hood face velocity and sounds an alarm when the airflow falls below safe levels. A glowing green light signals when conditions are again safe. The control monitor, which is mounted on the hood fascia, also contains a test/ reset button that allows the hood user to verify alarm readiness. The Air Alert 300 operates on a 9 volt DC circuit and comes complete with an adapter that can be plugged into any 120 VAC receptacle. Sash Stop Label Option L Half-Size Actual Label 2 1 /2" x 4" Sash Open Safety Label Designed to be used with a sash stop but may be used on any hood to indicate proper sash position for safe fume hood operation. Label is mounted on the left post at the sash stop position, close to the Sash Stop Controller Panel. Label is printed in black on clear vinyl. VFH-12/16-23

Supreme Air Fume Hood Options Stainless Steel Duct Collar Option C Stainless Steel Duct Collar may be specified on any Venturi fume hood as an addition to the standard FRP plenum and duct collar assembly. (Type 316L Stainless Steel) Distillation Rack Preparation Option D Venturi Fume Hoods may be prepared to accept a lattice style distillation rack. The rack consists of vertical and horizontal 1 /2" diameter rods, fastened with rod clamps to form a lattice of approximate 12 squares. Rods are available in Stainless Steel, Duralumin, or Fiberglass Reinforced Polyester (FRP) rods. Rod Assemblies must be Ordered Separately. (see below) Stainless Steel Rods Hood FRP Rods 48" High Interior 60" High Interior Length 48" High Interior 60" High Interior VDRS480148 VDRS600148 4'-0" / 48" VDRP480148 VDRP600148 VDRS480160 VDRS600160 5'-0" / 60" VDRP480160 VDRP600160 VDRS480172 VDRS600172 6'-0" / 72" VDRP480172 VDRP600172 VDRS480196 VDRS600196 8'-0" / 96" VDRP480196 VDRP600196 Duralumin Rods Hood 48" High Interior 60" High Interior Length VDRA480148 VDRA600148 4'-0" / 48" VDRA480160 VDRA600160 5'-0" / 60" VDRA480172 VDRA600172 6'-0" / 72" VDRA480196 VDRA600196 8'-0" / 96" Sliding Safety Shield Option S Sliding Safety Shield designed to provide protection to fume hood users from small explosions, splattering of chemicals, breaking glass, etc. Designed to be used on Vertical Rising Sash Bench Hoods only, this 12" wide x 1 /4" thick polycarbonate shield slides the full length of the hood face opening on ball bearing rollers suspended from a track at the top of the sash opening, with a guide at the bottom to keep the shield from swinging. When the shield is not in use, it can be easily removed from the upper track and stored until it is needed again for safety purposes. VFH-12/16-24

Supreme Air Fume Hood Options Stainless Steel Airfoil Option O Stainless Steel Airfoil in lieu of standard powder coated steel airfoil. Stainless Steel Sash Pulls Option Q Stainless Steel Pulls integrated into spoiler shaped sash foil. Tissue Screen Option T Tissue Screen protects the back baffle area just above the safety slot. Fabricated of perforated stainless steel, the screen blocks tissue and other light material from being swept up behind the upper baffle and into the exhaust system. VFH-12/16-25

Fume Hood Options Electrical Fixture Options Specification Grade GFCI Option S_ Hospital Grade GFCI Option H_ SK = GFCI-Specification Grade Black SV = GFCI-Specification Grade Ivory SW = GFCI-Specification Grade White SG = GFCI-Specification Grade Grey SR = GFCI-Specification Grade Red 120 volt GFCI specification grade, 20 amp, ground fault protected, double duplex receptacle. Note: One ground fault circuit interrupter will protect all outlets on the same circuit. When fume hood is pre-wired, each double duplex is wired to a separate circuit. HK = GFCI-Hosptial Grade Black HV = GFCI-Hosptial Grade Ivory HW = GFCI-Hosptial Grade White HG = GFCI-Hosptial Grade Grey HR = GFCI-Hosptial Grade Red 120 volt GFCI hospital grade, 20 amp, ground fault protected, double duplex receptacle. Note: One ground fault circuit interrupter will protect all outlets on the same circuit. When fume hood is pre-wired, each double duplex is wired to a separate circuit. Fan/Blower Switch Option K K = Fan/Blower Switch Motor rated starter switch with pilot light mounted in a single gang receptacle box complete with face plate, 120 volt pilot light, and double pole toggle switch with thermal overload protection for up to 1 HP single phase, 60 hertz 120/240 volt AC motors. (Thermal unit not provided) Mounted on left fascia post above Light/ Sash Stop Control Panel. Pre-wired Option U Pre-wired All Venturi Fume Hoods may be pre-wired at the factory. Pre wired hoods are wired using three circuits: one for each of the double duplex receptacles in each side post, and one for the Light/Sash Stop Control Panel. Hoods are wired using flexible metallic conduit to a single junction box located at the top of the hood for a single point connection. Pre-wired ADA Venturi Fume Hoods are furnished with only two circuits, one for the double duplex receptacles on the right side post, and one for Light/Sash Stop Control Panel on the left side post. Pre-wired hoods configured with a Fan/Blower Switch (Option K) include an extra circuit. VFH-12/16-26

Fume Hood Options Cord Port Option P1 Cord Ports provide convenient, safe passage of wires and tubes for equipment connections. Provided in both side posts. Replaces lowest service fitting holes. Auto Sash Return Option R1 Auto Sash Return Option provides an automatic sash return that lowers the sash to 18" from the full-open set-up position. When the sash is raised to the full open position a sash lock holds the sash open for set-up purposes. By pressing the electronic sash stop release button, the sash automatically closes to the 18" operating height. Auto Sash Operator Option R3 Automatic Sash Operator uses an Overhead Motion Sensor to monitor the area in front of the hood for the presence of lab personnel. Scanning at regular intervals, when it senses there has been no movement within the programmed period of time, it automatically closes the sash slowly and safely. When personnel are present, the sash will be able to be opened and closed manually. In addition to the motion sensor, a photoelectric sensor placed on the sash creates a light beam which scans the sash area for obstructions in the path of the sash. When an obstruction exists, the sash will halt its descent, and a warning light will signal that an obstruction exists. Once the obstruction is removed, the Sash Operator warning light will reset, and the unit will reengage. The Automatic Sash Operator is factory installed on the fume hood with all required mechanical connections to the sash shaft for proper operation, and prewired to a junction box located on the top of the hood. VFH-12/16-27