Pow-R-Way III Busway Service and Solutions

Similar documents
Pow-R-Flex low ampere busway

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Dry-Type Transformers Mini-Power Centers

Pow-R-Way III Low Voltage Busway. Product Focus. Pow-R-Way III Offers a Full Line of Low Voltage Busway to Meet the Needs of a Global Marketplace

100-Ampere Busway. Effective November 2005 New Information. Elbow, Busway and Cable Tap Box. Technical Data TD E

Pow-R-Way III low voltage busway. Meeting the needs of a global marketplace

Busway Construction. Bus Bars

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

BUSWAY Low Voltage (Pow-R-Flex)

Unitole UP kv Primary substations Motor control centres

MP-4000 Motor Protection

Capabilities Brochure

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

Busway. Siemens STEP 2000 Course. STEP 2000 Courses distributed by

WavePro LT Busway Cost effective solution for electrical distribution

Introduction. Upon completion of Busway you should be able to:

SPX9000 FR10 FR12 Adjustable Frequency Drives

6.1. Low Voltage Busway. Low Voltage Busway Pow-R-Way and 100V. Features, Benefits and Functions

PowerWave Bus System. For More Information Use your QR Reader THE NEXT GENERATION OF FLEXIBLE POWER DISTRIBUTION

Unitole UP kv Primary substations Motor control centres

Medium Voltage Metal-Enclosed Switches

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

SECTION LOW VOLTAGE DISTRIBUTION EQUIPMENT

W-VACi MV circuit breakers

Flexible, Customizable Power Solutions for Mission Critical Success

XIRIA Green, Smart, Compact solution

Xiria 24 kv Ring Main Unit

Low voltage busway Pow-R-Flex low ampere busway

Safety, Reliability and Performance verified with the KEMA KEUR mark. Series G Moulded Case Circuit Breakers

Medium Voltage Metal-Enclosed Switches

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Overview Brochure Integrated Power Distribution. Medium Voltage Assembly Solutions

Flexible. Intelligent. Trendsetting.

GE Consumer & Industrial Electrical Distribution. Spectra Series Busway. Busway vs. Wire & Conduit. imagination at work

Data Bulletin. Wire Temperature Ratings and Terminations INTRODUCTION WHY ARE TEMPERATURE RATINGS IMPORTANT?

Selection and Application Guide. busway system. Cost-effective Power Distribution Compact Design

Xiria 12 kv Ring Main Unit in IEC and ENATS design

Put the Power in Your Hands

Flexible, Customizable Power Solutions for Mission Critical Success

10 Commercial, Industrial, Agricultural Services

Engine Generator Circuit Breakers

Generator Fire Safety: Generator assemblies should be located outside the building.

O & M Manual for the EATON Generator Ready Loadcenter

SECTION PANELBOARDS

EATON Corporation David May J.C. Moots

www. ElectricalPartManuals. com Section 13 Switchgear Low Voltage

Get smart. Reduce energy consumption

HIGH POWERBAR COPPER UL857

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Innovac SVS/08 - SVS/ kv modular switchgear

City of Banning Electric Utility - Residential Self Generating Facility Program (Photovoltaic Systems <48kW)

Tradition. Technology. Innovation.

TO COME. CEP7 Solid-State Overload Relay for Motor Control Centers and Enclosed Control

Flexible, Customizable Power Solutions for Mission Critical Success

Introduction. Features. Intelligent Technologies Motor Control Center Structures

POWERBUS 225 Busway and Plug-In Units

A. This Section includes ac, enclosed controllers rated 600 V and less, of the following types:

PDI PowerWave 2 Bus System

Specification made simple for selective coordination in a compact size

Selection and application guide

POWERCON CORPORATION

Power Mod. Introduction.

Application guide. Tmax Link OEM UL 891 Switchboard Program

Multi-Pak Group Control

A. This Section includes Low Voltage Switchgear Work, as indicated on the drawings, and as specified herein.

Bulletin VX05 VANEAXIAL FANS

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

EXPLOSIONPROOF PROTECTION SIMPLIFIED PLEXPOWER LIGHTING AND POWER PANELBOARDS

EZTray. Cable Management Made Easy

Midwest Dry Type Transformers

Powering business worldwide

The easiest and fastest way to select and specify the right fuse

1. Division 26 Section "Elevator Shunt-Trip Fused Disconnect Switches".

Customer Requirements Downtown Secondary Network Service

Reliably Switching Highest Currents up to 2200 A

SECTION 500 METERING AND ASSOCIATED EQUIPMENT

W-SLC Medium Voltage fused contactor truck A safe, reliable and efficient motor starter

Electrical Safety and Reliability: Short-Circuit Current Rating (SCCR) Equipment SCCR made easy

Supply-Side PV Connections

A. Submit manufacturer's literature and technical data before starting work.

Features, Benefits and Functions

UNIVERSITY OF WASHINGTON Facilities Services Design Guide. Electrical. Switchboards. Basis of Design. Design Evaluation

Bolted Contact Pringle Switch. Cutler-Hammer Bolted Contact Pringle. Effective Date March 16, 2009 Replaces TD T.K

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

Busway Products Medium Voltage Busway Nonsegregated Phase Bus

Modular Standardized Electrical and Control Solutions for Fast Track Projects

4.5. Switchboards. Contents Description Instant Service Switchboards Product Selection...

GE Industrial Solutions. Spectra Series * Busway

Design Standards NEMA

Fuseology. Fuse Holders, Fuse Blocks, Power Distribution Blocks & Surge Suppression. Optima Fuse Holders & Overcurrent Protection Modules.

Cutler-Hammer. Installation Instructions for the Digitrip OPTIM Pole Trip Unit Installation and Operation with L-Frame Series C Circuit Breakers

RV Park Equipment Product Focus. Power Pedestals Distribution Equipment

IT. IEC Contactors, Starters, Overload Relays, and Accessories Product Focus

New Products for Integrated Electrical Systems/Questions and Answers/Resources. necdigest. Bringing a new level of electrical protection into the home

PlexPower Fused Factory Sealed Panelboard with Bus Bar Up to 30 Amps. Stainless Steel Enclosures

Quick selector reference guide. Pow-R-Stock panelboards, safety switches, and transformers

POWERPLEX PANELBOARD 1

A. Provide a complete system of overcurrent protective devises as indicated on the drawings, and as specified herein.

Conduit and Wire. Wire and Cable Whips. Bus Duct, Cable Trays, Overhead or Under Floor Raceways, Strut or Channel Systems

Combining the IQ250/260 & Power Xpert Gateway 600A equals intelligent hardware.

Transcription:

Pow-R-Way III Busway Service and Solutions Capabilities Busway Field Measurement Services Final Field Fit Program Express Bus Program Busway Value Calculator

Burj Dubai World's tallest building under construction, powered by Eaton's Cutler-Hammer Pow-R-Way III Busway.

Busway Pow-R-Way III SERVICE AND SOLUTIONS Taking Busway to New Heights! As a leader in providing quality, cutting-edge electrical distribution equipment, Eaton understands the importance of offering superior service and product solutions to its customers. This is often the difference that places Eaton above other manufacturers of electrical distribution equipment. Cutler-Hammer Pow-R-Way III Busway is becoming the preferred means of connecting electrical equipment in power distribution systems, due to its electrical efficiencies and cost-saving characteristics. To help ensure projects are kept on schedule, Eaton s Busway Team offers the following services and solutions: Busway Field Measurement Services This service is ideal for any project where there is an increased potential for making measurement errors. Final Field Fit Program This program was established to effectively manage the dimensional uncertainties that are often inherent in busway layouts. Express Bus Program This expedited shipment program is designed to help meet the needs of accelerated job site completion schedules or to help get critical loads on-line and operating. Busway Value Calculator This unique software program allows the installer to compare the total installed cost of busway installations against traditional cable/ conduit installations. All of the above programs are outlined in further details. To take full advantage of these programs or to obtain additional information, please contact your local Eaton sales office. Taipei 101 World's current tallest complete building, powered by Eaton's Cutler-Hammer Pow-R-Way III Busway.

Busway Field Measurement Services It s Better with Busway! Eaton s Busway Measurement and Layout Don t Lose Sleep Over Your Busway Project! Leave the details to us! On-site measurement by experienced factory trained personnel Cost-efficient and guaranteed to fit Solutions for every application: New installations Final field fits Add to existing Coordinate between new or existing equipment Rely on Eaton s busway measurement and layout service for your most complex projects. This service is your way to save time and money.

The purpose of the factory measurement service is to measure and provide layout drawings for each bus run. We are there to take the worry out of laying out the busway and avoid mistakes in measuring and laying out the busway, which could cost you time and money. In order to make the most of our site visit, we have outlined what to expect from our service and what we need in the way of preparation before our visit. 7 5-1/4 1 0 15 2-3/16 Service 4 5/8 1st Floor Our on-site measurement personnel are factory trained and experienced with busway products. We use handheld laser distance measuring tools to save time and ensure an accurate measurement. One set price includes travel expenses, site visit and measurement, and layout drawings for your approval. Expedited approval drawings within 2 weeks from the site visit. 3 4-1/2 F 2 6-3/4 4 7 5 1-1/2 10 7 Site Preparation The following information should be worked out before scheduling your on-site measurement: Are the walls, floor and other obstacles the busway will penetrate or be routed around in place for measurement? Are the termination points identified and in a fixed location? Where is your gear lineup? Will it be sitting on a pad? What are the utility requirements if applicable? Where is the transformer to be set? What are the on-site requirements and restrictions? (Minimum headroom, maximum height, etc.) Where is the busway being routed outside and throughout the building? What other trades are also occupying the area and where are they being routed? We will need the assistance of one person on the job site who is familiar with all of the above and can work with us for the day to complete the measurements for the busway layout. Scheduling To help ensure the best possible service, we only send engineers and technicians who are trained and experienced in busway measurements and layouts. As a result, we have a limited number of personnel available. Requests are fulfilled on a first come first serve basis. Please allow 2 weeks notice to schedule a site visit. We will accommodate expedited requests whenever possible. An additional fee will apply if service is required in less than 2 weeks. Guarantee Most variance in the layout dimensions can be accommodated with our Pow-R- Bridge coupling, which allows 1-inch adjustment per joint connection. Should there be a measurement error that exceeds this adjustment, we will provide a replacement piece in a timely manner at no additional charge. 1 1 Note This free replacement does not include changes made in the layout or site after the factory rep has completed the measurements. 2 8 F 4 11-3/4 MSB Rear EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Field Measurement Services 5

Final Field Fit Program Pow-R-Way III Low Voltage Busway The Exact Fit the First Time Eaton is dedicated to producing a quality product and delivering it on time. The Final Field Fit Program was established to effectively manage the dimensional uncertainties that are often inherent in busway layouts. This program has been successful for many years and it provides the assurance of an exact fit the first time. It allows for busway runs to be released for manufacture when certain dimensions are not yet determined. It also eliminates the costly delays that can occur when sections have to be remade in order to accommodate last-minute job site changes in routing. Benefits include: Exact fit the first time Eliminates incorrect pieces Facilitates on-time project completion

1. Customer Faxes Dimensions for F01 Final Field Fit piece shipped within 5 to 10 working days. 2. Details on Process Greenwood provides this information for customer reference: Drawing number Order number Phone number Fax number Customer must fill in this information before faxing to Greenwood: Final field fit piece dimension. Shipping information: Name Company name Phone number Fax number Date Other field fit items Requested shipping date What is a Final Fit Piece? A field fit section of busway is typically an elbow or a short section of feeder that is intentionally left out of a run for later shipment. It is most often a mutually agreed upon section between the customer and the plant. In Figure 1, the field fit piece is identified as item F01, a downward elbow flange. Upon release of the order, this item is kept on hold for field measurement. The contractor will install the busway (items A01 through A12) and is then able to obtain an exact dimension for the final field fit piece. In this case, the measurement for item F01 should be made from the top of SWGR 1 up to the outside edge of the busway (dimension A ) and from the outside edge of the busway back to the edge of the housing of item A12 (dimension B ). When Should the Program Be Used? If you are uncertain of the exact dimensions on long runs or if you have pathway obstructions that will require job site routing of the busway, this program can help you. Here s How the Final Field Fit Program Works 1. Review busway requirements with your Greenwood product engineer. Together, you can determine which piece should be field fit. Release all the busway except the field fit piece. (There is a limit to the number of field fit pieces that can be supplied, so please consult your Greenwood product engineer.) 2. The contractor installs the busway and measures the field fit piece dimensions. 3. The contractor can fax the dimensions directly to the Greenwood product engineer on the Final Field Fit Program Fax Sheet Figure 2. The contractor simply fills in the requested information and transmits the form. The Final Field Fit Fax Release Form is customized to each order and shipped to the job site with the busway. The field fit items will match the F items shown on the construction drawings provided by Eaton. It will also reference the Cutler- Hammer drawing number and General Order number. 4. The field fit piece will ship within 5 to 10 working days after receipt. Offset and combination offset fittings may take longer to ship. Also, if more than 5 field fit pieces release at the same time, the shipment lead-time may take longer than 5 to 10 working days. Contact the factory for lead-times. 1 2 A = B = Edge of Housing A12 (13 Min) B C L BUS T F01 A11 2 0 Final Field Fit Program Fax Release! Fax Direct to Greenwood factory. Ref. Drawing: G.O.#: Item #: Phone #: 864-942-6310 Fax #: 864-942-6339 Customer to provide dimensions indicated by letters on field fit section of busway. Edge of Housing "A" Dimension = "B" Dimension = B C L BUS Top of Gear 2 0 A (8.62 Min) 10 0 Name: Company: Phone #: Fax #: Date: List other field fit items released at this time: Requested Ship Date: A C L Cutout 20 0 Top of Switchgear T F Oppos 2 of A12 A12 Edge of Housing C A12 BUS (13 Min) B Hold F01 1 9 2 0 (8.62 min) A Swgr 1 Front A10 Standard ship lead-time is 5 to 10 working days from receipt of complete information. EATON CORPORATION Pow-R-Way III Busway Service and Solutions Final Field Fit Program 7

Express Busway Program Quick-Ship SM A Quick Dependable Solution Eaton s electrical business continues to be the leader in providing service and product solutions to its customers. When you need a complete run of busway fast to get critical electrical loads running or meet time-sensitive deadlines, Cutler-Hammer Express Bus is the solution.

Product Offering Indoor Plug-in Busway 800 to 2500 amperes copper Indoor Feeder Busway 800 to 2500 amperes copper Corner Joints Forward (right) Rearward (left) Upward Downward Tap Boxes End tap box Plug-in tap box Bus Plugs Fusible Circuit breaker Accessories End closer Wall/floor flange Hangers Program Highlights Eaton will ship 12 total pieces of busway in 5 working days or 24 total pieces in 10 working days after receipt of released order. Total pieces are inclusive of end tap boxes and corner joints. For pricing, special requests or needs, please contact your local Eaton sales office. Plug-in units and additional hangers are stocked and available in the warehouse. How the Program Works By using the electronic form in Outlook, it's quick and easy as 1-2-3. 1. Write in the catalog numbers and quantities of the pieces needed. 2. Write in and extend the pricing. Obtain book and net multipliers from your local sales office. 3. Fill out all the information in the electronic form on Outlook for EatonCare order entry. Fax in a copy of the distributor purchase order. Once received, your order will be entered in the system and shipped within 5 to 10 working days based upon the number of pieces ordered. Note: Order must be entered by your local Eaton sales representative. Pow-R-Way III Busway Feeder and plug-in indoor busway with copper conductors are available in 10-feet (3.0 m) and 6-feet (1.8 m) lengths. They can be used interchangeably without the use of special adapters or special splice plates, provided they are the same current and system rating. Pow-R-Way III is constructed with a lightweight and rugged, two-piece all-aluminum extruded housing, which is rated as a 50% ground path. Copper bus bars for plug-in applications have full-sized conductor tabs welded to their side edges to form the plug-in contact surfaces. Tabs are the same exact thickness as the conductors and are fully rated up to 800 amperes. Corner Joint Elbows When it comes to bends and turns in a bus run, the Pow-R- Way III corner joint is the most compact elbow in the industry. Given the complexity of today s industrial and commercial distribution systems, and the need to coordinate layouts with HVAC, plumbing and lighting requirements, space quickly becomes a critical factor. The Pow-R-Way III corner joint elbow can be installed in areas where traditional 90-degree elbows could never have been accomplished before. Due to its compact design, the corner joint also allows for layouts that provide optimum utilization of space. Critical section length that would normally be required for a traditional elbow leg length can now be dedicated to maximizing usable plug-in section length. The corner joint is as reliable as traditional elbows. It is seismically certified and exceeds the requirements of both the UBC and CBC (Zone 4). The corner joint is UL listed for indoor applications. Fittings and Accessories End cable tap boxes are available for all ratings in the Express Bus program. Plug-in cable tap boxes are also available and are listed in Catalog CA08101001E, Section 17. One horizontal hanger will be included for every 10 feet (3.0 m) of busway. Please specify flatwise or edgewise. Additional Information Product Brochure BR01701001E Technical Data TD01701001E Distribution Catalog CA08101001E Consulting Application Guide CA08104001E Electrical Solutions Catalog CA08105001E ABCs of Planning/Installation IM01701002E EATON CORPORATION Pow-R-Way III Busway Service and Solutions Express Busway Program 9

UPWARD/DOWNWARD CORNER JOINTS Wire Ampere Rating Copper Upward Shown T F X LC X LC L C (X) Upward (X) Downward Inches mm Inches mm 3-Phase 3-Wire 800 4.70 119.4 4.35 110.5 Housing Ground 1000 4.70 119.4 4.35 110.5 1200 4.70 119.4 4.35 110.5 1600 4.70 119.4 4.35 110.5 2000 4.70 119.4 4.35 110.5 2500 4.70 119.4 4.35 110.5 3-Phase 4-Wire 800 4.71 119.6 5.00 127.0 Housing Ground 1000 4.71 119.6 5.00 127.0 1200 4.71 119.6 5.00 127.0 1600 4.71 119.6 5.00 127.0 2000 4.71 119.6 5.00 127.0 2500 4.71 119.6 5.00 127.0 FORWARD/REARWARD CORNER JOINTS C L C L C L X Y T F Forward Shown C L Wire Ampere Rating Copper (X) (Y) Inches mm Inches mm 3-Phase 3-Wire 800 0.94 23.9 5.38 136.7 Housing Ground 1000 1.25 31.8 5.69 144.5 1200 1.50 38.1 5.94 150.9 1600 2.25 57.2 6.69 169.9 2000 2.88 73.2 7.31 185.7 2500 4.12 104.6 8.57 217.7 3-Phase 4-Wire 800 0.94 23.9 5.38 136.7 Housing Ground 1000 1.25 31.8 5.69 144.5 1200 1.50 38.1 5.94 150.9 1600 2.25 57.2 6.69 169.9 2000 2.88 73.2 7.31 185.7 2500 4.12 104.6 8.57 217.7 END CABLE TAP BOXES Wire Ampere Rating Copper LC L W Tap Box Width Length Inches mm Inches mm 3-Phase 3-Wire 800 12.00 304.8 50.00 1270.0 Housing Ground 1000 12.00 304.8 50.00 1270.0 1200 12.00 304.8 50.00 1270.0 1600 20.50 520.7 50.00 1270.0 2000 20.50 520.7 50.00 1270.0 2500 24.50 622.3 50.00 1270.0 3-Phase 4-Wire 800 12.00 304.8 50.00 1270.0 Housing Ground 1000 12.00 304.8 50.00 1270.0 1200 12.00 304.8 50.00 1270.0 1600 20.50 520.7 50.00 1270.0 2000 20.50 520.7 50.00 1270.0 2500 24.50 622.3 50.00 1270.0 10 EATON CORPORATION Pow-R-Way III Busway Service and Solutions Express Busway Program

DANGER DANGER DANGER EXPRESS BUS: PLUG-IN BUSWAY EXPRESS BUS: FEEDER BUSWAY Wire Ampere Rating Copper Copper 10' 0" Plug-in Length 6' 0" Plug-in Length 10' 0" Feeder Length 6' 0" Feeder Length Catalog Number Catalog Number Catalog Number Catalog Number 3-Phase 3-Wire 800 BX08C3HP120I BX08C3HP072I BX08C3HF120I BX08C3HF072I Housing Ground 1000 BX10C3HP120I BX10C3HP072I BX10C3HF120I BX10C3HF072I 1200 BX12C3HP120I BX12C3HP072I BX12C3HF120I BX12C3HF072I 1600 BX16C3HP120I BX16C3HP072I BX16C3HF120I BX16C3HF072I 2000 BX20C3HP120I BX20C3HP072I BX20C3HF120I BX20C3HF072I 2500 BX25C3HP120I BX25C3HP072I BX25C3HF120I BX25C3HF072I 3-Phase 4-Wire 800 BX08C4HP120I BX08C4HP072I BX08C4HF120I BX08C4HF072I Housing Ground 1000 BX10C4HP120I BX10C4HP072I BX10C4HF120I BX10C4HF072I 1200 BX12C4HP120I BX12C4HP072I BX12C4HF120I BX12C4HF072I 1600 BX16C4HP120I BX16C4HP072I BX16C4HF120I BX16C4HF072I 2000 BX20C4HP120I BX20C4HP072I BX20C4HF120I BX20C4HF072I 2500 BX25C4HP120I BX25C4HP072I BX25C4HF120I BX25C4HF072I EXPRESS BUS: FITTINGS Wire Ampere Rating Copper Upward Corner Joint Downward Corner Joint Forward Corner Joint Rearward Corner Joint Catalog Number Catalog Number Catalog Number Catalog Number 3-Phase 3-Wire 800 BX08C3HAUCJI BX08C3HADCJI BX08C3HAFCJI BX08C3HARCJI Housing Ground 1000 BX10C3HAUCJI BX10C3HADCJI BX10C3HAFCJI BX10C3HARCJI 1200 BX12C3HAUCJI BX12C3HADCJI BX12C3HAFCJI BX12C3HARCJI 1600 BX16C3HAUCJI BX16C3HADCJI BX16C3HAFCJI BX16C3HARCJI 2000 BX20C3HAUCJI BX20C3HADCJI BX20C3HAFCJI BX20C3HARCJI 2500 BX25C3HAUCJI BX25C3HADCJI BX25C3HAFCJI BX25C3HARCJI 3-Phase 4-Wire 800 BX08C4HAUCJI BX08C4HADCJI BX08C4HAFCJI BX08C4HARCJI Housing Ground 1000 BX10C4HAUCJI BX10C4HADCJI BX10C4HAFCJI BX10C4HARCJI 1200 BX12C4HAUCJI BX12C4HADCJI BX12C4HAFCJI BX12C4HARCJI 1600 BX16C4HAUCJI BX16C4HADCJI BX16C4HAFCJI BX16C4HARCJI 2000 BX20C4HAUCJI BX20C4HADCJI BX20C4HAFCJI BX20C4HARCJI 2500 BX25C4HAUCJI BX25C4HADCJI BX25C4HAFCJI BX25C4HARCJI EXPRESS BUS: TAP BOXES & ACCESSORIES Wire Ampere Rating Copper End Cable Tap Box End Closer Wall/Floor Flange Catalog Number Style Number Style Number 3-Phase 3-Wire 800 BX08C3HAETRI BVD0156G01 BVD0299G01 Housing Ground 1000 BX10C3HAETRI BVD0156G02 BVD0299G02 1200 BX12C3HAETRI BVD0156G03 BVD0299G03 1600 BX16C3HAETRI BVD0156G05 BVD0299G05 2000 BX20C3HAETRI BVD0156G06 BVD0299G06 2500 BX25C3HAETRI BVD0156G08 BVD0299G08 3-Phase 4-Wire 800 BX08C4HAETRI BVD0156G01 BVD0299G01 Housing Ground 1000 BX10C4HAETRI BVD0156G02 BVD0299G02 1200 BX12C4HAETRI BVD0156G03 BVD0299G03 1600 BX16C4HAETRI BVD0156G05 BVD0299G05 2000 BX20C4HAETRI BVD0156G06 BVD0299G06 2500 BX25C4HAETRI BVD0156G08 BVD0299G08 Please specify voltage: X=1 208/120 volts X=2 480/277 volts X=3 600/347 volts X=6 600 volts Hangers: Vertical and horizontal hangers are available. For horizontal hangers, please specify Hook or Angle and Flatwise or Edgewise. Plug-in Units: For fusible and circuit breaker plug-in units, please see catalog CA08101001E, Section 17. Dimensions: For physical dimensions, ratings and product details, please see Technical Data TD01701001E. EATON CORPORATION Pow-R-Way III Busway Service and Solutions Express Busway Program 11

Busway Value Calculator Pow-R-Way III Low Voltage Busway The Advantages of Busway There are many definite advantages to busway over cable and conduit distribution systems: Less Man-hours for Installation Busway is engineered and built to fit your specific layout needs. It is shipped to the job site ready for installation. Busway can be installed quickly and efficiently with only 40% of the labor required to install a conduit and wire system. Compact Size Due to its sandwich style design, busway has a very compact cross-sectional area and therefore occupies far less space than multiple conduits. Reusable, Expandable, Flexible As distribution needs change, you can easily relocate existing busway runs or add new sections to extend bus runs into other areas of your facility. A Safe and Versatile Design Pow-R-Way III meets the requirements of UL, NEMA, CSA and IEEE. Additionally, Pow-R-Way III is seismically qualified to both the UBC and CBC, exceeding Zone 4 worst case levels. The conductor bars are totally enclosed in a nonventilated aluminum housing which provides the highest short circuit ratings in the industry today. All bus plugs are polarized to prevent improper installation and the plug-in outlets are rated as IP2X for finger safety to IEC 529. Lower Installed Cost The savings in labor can generate a total installed cost reduction of as much as 40% compared to a conduit and cable installation.

Busway Saves Time and Money Myth Busway is more expensive than cable and conduit. Fact With the higher wholesale costs of cable and conduit, busway is very competitive when comparing material costs. However, it is the reduction in the number of man-hours required for installation that provides a significantly lower installed cost with busway than with pipe and wire. Myth Busway requires accurate layout and measurements. That takes too much time and effort and leaves room for errors. Fact Accurate layouts can be done quickly with the help of Eaton s Cutler-Hammer Greenwood plant. Customer approval drawings are mailed 2 weeks after receipt of the order. The Final Field Fit Program provides the means to effectively manage the dimensional uncertainties that are often inherent in busway layouts. The savings realized with a busway installation should compensate for the time and effort required. Myth In the low to mid-range (225 1600 ampere) ratings, there are no savings. Fact Busway can be competitive at any rating. A number of variables determine the installed cost of a distribution system. Contact Eaton for application assistance. Evaluating a Comparison When you evaluate your own job comparison, try an aluminum or copper busway alternate against copper cable. As you can see from the table above, aluminum and copper busway required approximately 1/3 of the installation time. Pow-R-Way III has many features that are beneficial, such as Class B insulation, an integral housing ground, an isolated ground option and a 200% neutral option. Contact your Eaton sales engineer for more information. To learn more about Eaton s innovative Cutler-Hammer products and solutions call 1-800-525-2000, for engineering services call 1-800-498-2678, or visit www.eaton.com. THERE IS AN APPLICATION FOR BUSWAY IN EVERY MARKET Facility Type Application Busway Advantage High Rise Riser feeder busway with Lower installed costs and Construction plug-in sections to distribute more efficient distribution power at each floor. of power. Industrial Feeder busway for tie runs The versatility of busway Plant between switchgear and multiple provides the user with the load plug-in busway to feed individual processes. ability to easily expand the distribution system as needs change. Institutional Single load feeder busway The compact cross-sectional and plug-in busway to feed size of busway allows for the specific loads. maximum utilization of needed space. Commercial Main service entrance feeder Safe distribution of power busway and plug-in busway for with the added value of tenant feeds and distribution. tenant metering from IQ Energy Sentinel bus plugs. 2000 Ampere Utility Connection 2000 Ampere Utility Connection Switchboard or Switchgear Machine A Busway Machine B Motor Control Center Machine C Myth Busway takes too long to get to the job site while pipe and wire is always available. Fact Our lead-times are more competitive than ever and Greenwood can handle most Quick-Ship requests to meet the project requirements. Switchboard or Switchgear Panelboard Panelboard Machine A Cable and Conduit Machine B Motor Control Center Machine C EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Value Calculator 13

Determine a Cost- Effective Solution The Busway Value Calculator has been developed to help customers determine if Cutler-Hammer Pow-R-Way III Busway or cable and conduit is the most cost-effective solution for any given application. This user-friendly tool does a side-by-side total installed cost comparison between busway and cable and conduit. With the lightweight, compact design of Pow-R-Way III Busway, there are significant labor cost savings resulting in an overall installed cost savings over cable and conduit systems. How It Works The Busway Value Calculator utilizes the NECA labor unit system to help calculate the labor costs associated with installing cable and conduit systems as well as busway systems. There are no hidden tricks and the user has full control of the comparison. While default pricing is included, all data, from the NECA labor unit values to material costs, can be adjusted to match your costs and efficiencies. This also allows you to see cost impacts as different variables change. Based upon your fully burdened labor rate and material costs, the calculator configures a material cost comparison, labor cost comparison and a total cost comparison as well as bills of material for both. Most selections may be made via drop-down menus. Once the ampere rating of the system is selected, the Busway Value Calculator automatically sizes the conduit and cable and determines the number of each per phase. This is done per NEC guidelines and tables. This may also be done manually within the program. The final comparison results may be printed in a report format or exported as a Word document and saved. Listed below is a cost comparison for a 1600 ampere tie run between two switchboards. The bill of material is for 300 feet, 3-phase, 4-wire with ground, eight elbows and two switchboard connections. Rigid conduit is used with 500 kcmil THHN copper cable. The fully burdened labor rate is set at $35.00 per hour. Sample Cost Comparison CONDUIT & CABLE METHOD Equipment Quantity Material Labor Total Cost 3 1/2" Rigid Steel Conduit 1500 ft. $14,880.00 $13,125.00 $28,005.00 Elbow(s) 40 $1,560.00 $3,500.00 $5,060.00 Bushing-Lock Nuts 10 $168.00 $490.00 $658.00 Pull Boxes 3 $96.00 $225.75 $321.75 Trapeze Hangers 39 $351.00 $2,593.50 $2,944.50 Conduit Channel Clamps 105 $367.50 $220.50 $588.00 500 kcmil THHN Wire 6320 ft. $30,968.00 $9,732.80 $40,700.80 250 kcmil Ground Wire 1580 ft. $3,950.00 $1,769.60 $5,719.60 Compression Lugs 50 $390.00 $1,750.00 $2,140.00 Method Total $86,137.65 BUSWAY METHOD Equipment Quantity Material Labor Total Cost 1600 Ampere Feeder Busway 300 ft. $50,880.00 $9,450.00 $60,330.00 Busway Elbow(s) 8 $2,110.40 $302.40 $2,412.80 Busway Gear Flange 2 $796.00 $378.00 $1174.00 Busway Hanger Rods 39 $13.00 $137.00 $149.00 Method Total $64,066.49 Note: All busway components are based on indoor, copper design with 50% integral housing ground. 14 EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Value Calculator

Additional Comparisons In addition to the installed cost comparison, the Busway Value Calculator does a space savings comparison and voltage drop comparison between busway and cable and conduit systems. Space Savings With the compact design of the Pow-R-Way III Busway, it occupies far less space than that of multiple conduits. In the sample comparison shown, conduit would occupy 92 square inches of space along the run compared to only 32 square inches for Pow-R-Way III Busway. Voltage Drop Efficiencies With Pow-R-Way III Busway only having one or two conductors per phase and the Pow-R-Bridge joint design, its voltage drop is much lower than that associated with cable. In the sample comparison shown, the line-to-line voltage drop for cable is 39.1 volts at the end of the run. Pow-R-Way III Busway only has an 8.8 drop in voltage at the end of the run. This means much lower losses allowing a more efficient use of energy. Volts 45 40 35 30 25 20 15 10 5 0 Cable Space Savings Voltage Drop Comparison Busway Conductor System For a free copy of the Busway Value Calculator software, please contact your local Eaton sales office. Also look for our newly updated Web-based version to be made available in the near future. EATON CORPORATION Pow-R-Way III Busway Service and Solutions Busway Value Calculator 15

Eaton s electrical business is a global leader in electrical control, power distribution, uninterruptible power supply and industrial automation products and services. Eaton s global electrical brands, including Cutler-Hammer, Powerware, Holec and MEM, provide customer-driven PowerChain Management solutions to serve the power system needs of the industrial, institutional, government, utility, commercial, residential, IT, mission critical and OEM markets worldwide. Eaton Corporation is a diversified industrial manufacturer with 2006 sales of $12.4 billion. Eaton is a global leader in electrical systems and components for power quality, distribution and control; fluid power systems and services for industrial, mobile and aircraft equipment; intelligent truck drivetrain systems for safety and fuel economy; and automotive engine air management systems, powertrain solutions and specialty controls for performance, fuel economy and safety. Eaton has 62,000 employees and sells products to customers in more than 125 countries. For more information, visit www.eaton.com. Eaton Corporation Electrical Group 1000 Cherrington Parkway Moon Township, PA 15108 United States 877-ETN-CARE (877-386-2273) Eaton.com PowerChain is a trademark of Eaton Corporation. Cutler-Hammer and Pow-R-Way III are registered trademarks of Eaton Corporation. UL is a registered trademark of Underwriters Laboratories Inc. CSA is a registered trademark of the Canadian Standards Association. NEMA is the registered trademark and service mark of the National Electrical Manufacturers Association. Uniform Building Code (UBC) is a trademark of the International Conference of Building Officials (ICBO). IEEE is a registered trademark of The Institute of Electrical and Electronics Engineers, Incorporated. Outlook is a registered trademark of Microsoft Corporation. 2007 Eaton Corporation All Rights Reserved Printed in USA Publication No. BR01701002E / Z5761 August 2007