Square D www.squared.com FOR CURRENT INFORMATION Molded Case Circuit Breakers for Mining s These circuit breakers with the properly selected trip range provide protection for trailing cables in compliance with the Federal Register for Mining s. The thermal-magnetic circuit breakers listed below have thermallyresponsive trip elements in addition to adjustable instantaneous trip Thermal-Magnetic For Mining s Class mechanisms. They allow for independent selection of thermal and magnetic trip characteristics. The circuit breakers are identified by a T" in the suffix of the catalog number. See selection chart below. For MAG-GARD instantaneous trip magnetic-only circuit breakers refer to Square D Digest. Adjustable Magnetic Trip Range - s* Low 75 1 0 7 0 High 1 2 5 0 12 10 00 Circuit Breaker FAL3 FAL3 FAL3 KAL3 KAL3 KAL3 KAL3110 KAL31 KAL31 KAL3175 KAL3 KAL3 KAL3110 KAL31 KAL31 KAL3175 KAL3 KAL32 KAL32 LAL31 LAL31 LAL3175 LAL3 LAL32 LAL32 KAL31 KAL31 KAL3175 KAL3 KAL32 KAL32 KAL31 KAL3175 KAL3 KAL32 KAL32 LAL31 LAL3175 LAL3 UVL32 LAL32 LAL30 LAL33 LAL3 MAL30 MAL33 KAL3 KAL32 KAL32 LAL3 LAL32 LAL32 LAL30 LAL33 LAL3 Suffix 13T 14T 1T T T T T T T $ 32. 32. 778. 4. 4. Adjustable Magnetic Trip Range - s* Low High 0 11 12 10 17 00 00 0 00 22 00 0 00 0 00 0 0 Circuit Breaker MAL30 MAL33 MAL3 MAL34 MAL3 KAL32 KAL32 KAL32 LAL32 LAL30 LAL33 LAL3 MAL33 MAL3 MAL34 MAL3 MAL3 LAL30 LAL33 LAL3 MAL30 MAL33 MAL3 MAL34 MAL3 MAL3 MAL3 MAL3 LAL33 LAL3 MAL3 MAL34 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 MAL3 Suffix T T 31T 31T T T T T T T T T 44T 44T 44T T T T 4T 4T $4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 4. 3. 3. 4. 4. 3. 3. 4. 3. 3. 3. 3. * Magnetic trip setting tolerances are -% and +% from nominal values shown. MAG-GARD is a Registered Trademark of Square D Company or related companies. DE1 Discount Schedule 5-13
Selection Information Class 0,, www.squared.com A Frame A Frame GJL Circuit Breaker Type FA (2 V) FA FH FHh FH FC FI FY GJL of Poles 1, 2, 3 1 2, 3 1 1 2, 3 2, 3 2, 3 1 3 Current Range Interrupting s 2 Vac 10 18 5 5 0 14 UL/CSA/NOM 4Y/277 Vac 18 18 5 5 0 14 5 (ka RMS) 4 Vac 18 5 0 5 (/ Hz AC) Y/347 Vac 14 18 18 Vac 14 18 DC s 2 Vdc 5c 10c 10 10c 10c 0 Vdc b IEC 4/2 Vac (Icu/lcs)f 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 10/2.5 /1.5 5/5 IEC / Hz For additional IEC ratings, see Supplemental Digest. Special s Fed. Specs W-C-375B/GEN HACR (2, 3-pole) Connections/Terminations Unit Mount I-Line Rear Connection Drawout Optional Lugs Accessories and Modifications Shunt Trip ag a a a a Undervoltage Trip ag a a a a Auxiliary Switches ag a a a a Alarm Switch ag a a a a a a a Motor Operator Handle Operators Mechanical Interlocks (3-pole) d d d Handle Padlock Attachment Cylinder Lock (3-pole) a a a a Optional GF Protection e e e e e Trip System Type Thermal-magnetic Instantaneous-only (MCP) Molded Case Switch (Automatic) Electronic Enclosures (Pages -51-54) General Purpose (NEMA 1) Raintight (NEMA 3R) Dustight (NEMA 12) Watertight (NEMA 4, 4X, 5) Explosion Proof (NEMA 7, 9) Height IN (mm) (2) (2) (2) 8 (3) 4.72 (1) Dimensions (3P Unit Mount) Width IN (mm) 4.5 (114) 4.5 (114) 4.5 (114) 4.5 (114) 3.54 () Depth IN (mm) 4.13 (105) 4.13 (105) 4.13 (105) 4.75 (121) 3.94 () Pages (Unit Mount)/(I-Line) -/8- Pages -/8- Pages -/8- Page -21 Note: All circuit breakers on this chart are UL Listed and CSA Certified unless otherwise noted. a Factory-installed option only e Requires factory-installed G Shunt trip and 3-pole module. b Ungrounded UPS systems only. f Dual UL and IEC ratings and CE markings on circuit breakers. For additional IEC ratings, see Supplemental Digest. See Supplemental Digest. g Not available on 1-pole FA (2 V). c 1-pole has 1 Vdc rating only. h 5 ka @1 Vac. d Requires breaker with WB suffix. -4 05 Schneider Electric
Thermal-magnetic Molded Case Circuit Breakers Frame Class www.squared.com Thermal-magnetic molded case circuit breakers shown on pages - -24 are permanent trip UL Listed, CSA Certified, IEC rated, and also meet the requirements of Federal Specification W C 375B/GEN as indicated on pages -4-7. For I-Line molded case circuit breakers, see listings on pages 8-8-28. Interrupting s (ka) FAL 1-pole s FAL/FHL 2-pole s FAL/FHL/FCL 3-pole s FAL2 FAL4 FCL 2 V 10 18 (1P), (2, 3P) 4 V 18 5 V Circuit Breaker Termination Options (Third character of catalog number) F=No Lugs L=Lugs both ends M=Lugs ON end only P=Lugs OFF end only Accessories. pages -3-38 Optional Lugs.. pages -43, -44 Dimensions.. pages -49, - Enclosures pages -51-54 F-frame A, Thermal-magnetic (2 Vac) Trip Settings Standard Interrupting Hold Trip 1-pole, 1 Vac 2-pole, 2 Vac 3-pole, 2 Vac a FCL 2-pole circuit breaker built using 3-pole module. b FCL circuit breakers are not rated for 2 Vdc. FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL12 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL22 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL32 F-frame A, Thermal-magnetic (4 Vac) Trip Settings Standard Interrupting Extra High Interrupting Hold Trip 1-pole, 277 Vac, 1 Vdc FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL1 FAL14 2-pole, 4 Vac, 2 Vdcba FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL24 3-pole, 4 Vac, 2 Vdcb FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL34 $ 8. 8. 8. 8. $........ FCL2. FCL2 5. FCL2 5. FCL2 5. FCL2 5. FCL24 $ 1. 1. 1. 1. FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL3 FCL34 $ $ 32. 32. 32. 32. $3. 3. 3. 3. 3. 3. 3. 3. 3. Terminal Wire Range ALFA ALFA or ALFA ALFA or ALFA ALFA or Terminal Wire Range FA Lugs FC Lugs $ 95. 95. $1. 1. 1. 1. 1. 1. 1. 1. 1. ALFA ALFA ALFA ALFA ALFA ALFA CUFA4 (1) #14 #10 AWG Cu only ALFA4 (1) #14 #3 AWG Cu or (1) #12 #1 AWG Al CUFA4 (1) #14 #10 AWG Cu only ALFA4 (1) #14 #3 AWG Cu or (1) #12 #1 AWG Al - 10/23/04 DE2 Discount Schedule 04 Schneider Electric 10/23/04
www.squared.com Thermal-magnetic Molded Case Circuit Breakers, 2 Frame Class 5,, 734, 8 FIL3 GJL 3-pole circuit breaker F-frame A, Thermal-magnetic ( Vac) Trip Settings Hold Trip 1-pole, 277 Vac, 1 Vdc 2-pole, Vac, 2 Vdc 3-pole, Vac, 2 Vdc Standard Interrupting High Interrupting Current Limiting Terminal Wire Range FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL2 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 FAL3 $ $4. 4. 4. 4. 4. 4. 4. 4. 4. FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL1 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL2 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 FHL3 $1. 1. 1. 1. 1. 1. 1. 1. 1. $ 2. 2. 2. 2. $ 5. 5. 5. 5. 5. 5. 5. 5. 5. FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL2 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 FIL3 $ $ ALFA ALFA ALFA ALFA ALFA ALFA QBL 2 and 3-pole 2 s Powerpact G-frame A, Thermal-magnetic (Y/347 Vac) 3-pole, Vac, Vdc Trip Settings J Interrupting Terminal Wire Range Hold Trip 10 10 10 10 1 1 1 1 1 1 GJL3 GJL3 GJL3 GJL3 GJL3 GJL3 GJL3 GJL3 GJL3 GJL3 $ 132. 132. 132. 132. #8 #1/0 AWG Al Interrupting s (ka) FAL FHL FIL 2 V (1P: A), 5 (2, 3P) 0 4 V 18 (2, 3P) 0 V 14 18 (2, 3P) GJL QB QD QG QJ 2 V 10 5 d 4 V 5 V 18c c GJL is rated 18 ka at Y/347 Vac. d 3-pole QJ circuit breakers are rated at 8Y/1 Vac only. Accessories.. pages -3-38 Optional Lugs. pages -43, -44 Dimensions pages -49, - Enclosures. pages -51-54 04 Schneider Electric 7/14/04 7/14/04 Powerpact Q-framea 2 A, Thermal-magnetic (2 Vac) Trip Settings Hold Trip B Interrupting D Interrupting G Interrupting J Interrupting u 2-pole, 2 Vac 0 1 QBL2 $31. QDL2 $ 72. QGL2 $1014. QJL2 $12. 0 1 QBL2 31. QDL2 72. QGL2 1014. QJL2 12. 0 1 QBL2 31. QDL2 72. QGL2 1014. QJL2 12. 10 2 QBL22 31. QDL22 72. QGL22 1014. QJL22 12. 110 10 2 QBL22110 31. QDL22110 72. QGL22110 1014. QJL22110 12. 1 10 2 QBL221 31. QDL221 72. QGL221 1014. QJL221 12. 1 10 2 QBL221 31. QDL221 72. QGL221 1014. QJL221 12. 175 10 2 QBL22175 31. QDL22175 72. QGL22175 1014. QJL22175 12. 0 10 2 QBL220 31. QDL220 72. QGL220 1014. QJL220 12. 2 10 2 QBL222 31. QDL222 72. QGL222 1014. QJL222 12. 2 10 2 QBL222b 42. QDL222b 1029. QGL222b 1313. QJL222b 5. 3-pole, 2 Vac 0 1 QBL3 832. QDL3 1189. QGL3 128. QJL3 184. 0 1 QBL3 832. QDL3 1189. QGL3 128. QJL3 184. 0 1 QBL3 832. QDL3 1189. QGL3 128. QJL3 184. 10 2 QBL32 832. QDL32 1189. QGL32 128. QJL32 184. 110 10 2 QBL32110 832. QDL32110 1189. QGL32110 128. QJL32110 184. 1 10 2 QBL321 832. QDL321 1189. QGL321 128. QJL321 184. 1 10 2 QBL321 832. QDL321 1189. QGL321 128. QJL321 184. 175 10 2 QBL32175 832. QDL32175 1189. QGL32175 128. QJL32175 184. 0 10 2 QBL320 832. QDL320 1189. QGL320 128. QJL320 184. 2 10 2 QBL322 832. QDL322 1189. QGL322 128. QJL322 184. 2 10 2 QBL322b 18. QDL322b 128. QGL322b 2. QJL322b 2310. a Replacement lugs are not available for Powerpact Q-frame circuit breakers. Lugs for the Powerpact Q-frame circuit breakers accept (1) #4 AWG 0 kcmil. b 2 A lugs are suitable for copper conductors only. ude2a DE2 Discount Schedule u u u -21
www.squared.com Electrical Accessories Used on Thermal-magnetic and Electronic Trip Circuit Breakers Molded Case Circuit Breakers Factory-installed Electrical Accessories Accessory SHUNT TRIP GROUND- FAULT SHUNT TRIP UNDER VOLTAGE TRIP TIME DELAY UNIT AUXILIARY SWITCHES ALARM SWITCHES Description Trips the circuit breaker from a remote location by means of a trip coil energized from a separate circuit. A 1 V shunt trip will operate at 55% or more of rated voltage. All other shunt trips will operate at 75% or more of rated voltage. For use with momentary or maintained push button. Sure Trip Capacitor Unit requires 48 Vdc shunt trip. Leads: (2) Black #18 AWG Cu. Trips the circuit breaker electrically using the signal from a Micrologic Ground-Fault Module. For use only with obsolete GP Ground-Censor system or add on ground-fault module. Leads: (2) Orange #18 AWG Cu. Trips the circuit breaker electrically when a control circuit falls below to % of nominal (not field adjustable). Picks up at 85% of nominal voltage. UVR must be energized in order to close the circuit breaker. Leads: (2) Brown #18 AWG Cu leads. Provides adjustable time delay for UVR of 0.1 to 0. second before circuit breaker trips. For use only with -1121 UV trip. Adjustable time delay (0.1 to 0. second). I-Line unit requires 1.5 in. (38 mm) of mounting space. Leads: (2) Brown #18 AWG Cu and (2) Black/White #18 AWG Cu. Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. Max. Load = FA, FH, FC, FI, KA, KH, LC, LE, LI, LX, LXI. 10 A @ 1 2 Vac π hp @ 1 2 Vac, 5 A @ Vdc Leads: Yellow for A, Blue for B, Striped for common #18 AWG Cu. Used with control circuits and actuated only when the circuit breaker has tripped. Standard construction includes a normally open contact. Max. Load = 10 A @ 1 2 Vac Max. Load = A @ Vdc Leads: (2) Red #18 AWG Cu. Rated Voltage Coil Burdene Suffix List Adderf AC 24 21 VA -1042a $ 3. 1 24 VA -1021c 3. 8 107 VA -1021 3. 2 4 VA -1021 3. 277 14 VA -1037a 3. 4 VA -1037a 3. DC 24 3 VA -1027 3. 48 3 VA -1028 3. 1 44 VA -1029 3. 2 VA -10b 3. -Gb 3. AC 24 1 2 DC 24 DC 48 AC 1 5 VA 8 VA 8 VA 2 VA 3 VA -1143b -1121-1124 -1127-1128 No. Unit Mt. I-Line 3. 3. 3. 3. 3. UVTD UVTDI 1294. 1A/1B See See -1212 8. 2A/2B load info. in App. load info. in App. -12 4. 3A/3B text at left text at left -134d 533. 1A 1A 1B 1B AC 2 DC 28 AC 2 DC 28 See load info. in App. text at left -2-2 -2103-2103 8. 8. 8. 8. Electrical accessories are available on all molded case circuit breakers except FY, QB, QD, QG, QJ and QOM1 circuit breakers. All AC electrical accessories shown at left are rated for / Hz. Add % to accessory price for each field-installable accessory that is factoryinstalled. See page -38 for field-installable accessories. Note: Alarm switch is the only accessory available for 1-pole FA circuit breakers. Combination accessories may be ordered by description, i.e., 1021 and 1212. a Not available on FI, KI or KC circuit breakers. b Not available on LC, LE, LI, LX, LXI circuit breakers. c LC, LE, LI, LX, and LXI circuit breakers operate at 75% or more of rated voltage. d Not available in FA, FC, FH, FI and KI circuit breakers. e Coil burden values do not apply to LC, LE, LI, LX and LXI. Consult Field Sales Office for more information. f List price for field-installed accessories. See page -38. UVTD Wiring Diagram Time Delay Unit UVTD Black Wire 1 Vac White Wire Neutral Brown Wire Brown Wire SQUARE D CIRCUIT BREAKER with 1 Vac / Hz ma Undervoltage Trip GJL Circuit Breaker Accessories Electrical and mechanical accessories listed below are for use with GJL instantaneous-trip and thermal-magnetic circuit breakers. All AC electrical accessories shown below are rated for / Hz. Shunt Trip for GJL Circuit Breaker Undervoltage Trip for GJL Circuit Breaker Alarm/Auxiliary Switch for GJL Circuit Breaker Field-installable Electrical Accessories for GJL Circuit Breakers Accessory Description Rated Voltage Coil Burden No. Shunt Trip Undervoltage Trip Trips the circuit breaker from a remote location by means of a trip coil energized from a separate circuit. All shunt trips will operate at 55% or more of rated voltage. Trips the circuit breaker electrically when a control circuit falls below to % of nominal voltage. (Not field adjustable.) Picks up at to 85% of nominal voltage. UVR must be energized in order to close the circuit breaker. AC 1 8 2 277 4 DC 24 48 1 2 AC 1 8 2 277 4 DC 24 48 1 2 ma 29 ma ma 22 ma 13 ma 2 ma 1 ma 48 ma 24 ma ma 29 ma ma 22 ma 13 ma 2 ma 1 ma 48 ma 24 ma GSA GSB GSC GSD GSH GSO GSP GSR GSS GUA GUB GUC GUD GUH GUO GUP GUR GUS $ Auxiliary Switch Monitors circuit breaker contact status and provides a remote signal indicating the circuit breaker contacts are OPEN or CLOSED. s: 3A- Vac, A-4 Vac, 0.3A-2 Vdc, 0.8A-1 Vdc AACg 198. Alarm Switch Used with control circuits and is actuated only when the circuit breaker has tripped. s: 3A- Vac, A-4 Vac, 0.3A-2 Vdc, 0.8A-1 Vdc AACg 198. Field-installable External Accessories DIN Rail Adapter Hardware that allows mounting on x mm DIN rail. GYR 2.00 Terminal Shields Used to prevent accidental contact with live parts. GYT.00 Padlock Attachment Prevents access to unauthorized personnel. Locks in OFF position only. Suitable for padlock with a shaft diameter up to 0.312 in. (8 mm). AHP 13.10 Cover Screw Seal (10) Cover Screw Seals to prevent unauthorized removal of circuit breaker cover. ACS 12. g Same accessory depends on installation location. Switch has common and both normally open and normally closed contacts. See pages - -42 for accessories for Powerpact circuit breakers. 05 Schneider Electric DE2 Discount Schedule -37