- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Application Explosionproof circuit breaker enclosures are used where hazardous materials are handled or stored. These units are used for overload and short circuit protection, control of lighting and power circuits. Features Precision machined flame path between box and cover. Bolt on stainless steel slotted mounting feet. Stainless steel, captive Quad-Lead cover bolts are standard (disengaged in 1-1/ turns). Ground lug package and installation instructions for termination of ground wire enclosed. External operating handle with stops for limiting handle travel. Breaker operators can be locked in the ON or OFF position (up to 3 padlocks). External flange maximizes internal space. Standard outlets top and bottom for line and load wiring. Plugged 1/" outlets top and bottom for breather and drain. Breakers mounted on a galvanized steel removable pan. Enclosures are designed to accept GE, Square D and Cutler-Hammer circuit breakers. O-ring gasket insures watertight integrity. - and 3-pole versions are standard. For 4-pole versions, contact your local representative. For 65,000 AIC ratings contact your local representative. Standard Materials Bodies and covers: copperfree (4/10 of 1% max.) aluminum Cover bolts, hinges, breaker and operator shafts: stainless steel Hinges: stainless steel O-ring: neoprene Standard Finishes Bodies and covers: gray epoxy powder coat inside and outside standard Options Must be listed in alphanumeric sequence at the end of the catalog number. Auxiliary switch (1A or 1B), add suffix AS1. Auxiliary switch (A or B), add suffix AS. Breather, NEMA 4X (includes outlet and installation), add suffix BR. Drain, NEMA 4X (includes outlet and installation), add suffix DN. External grounding stud, add suffix EGS. Plastic nameplate, " x 4", 1/8" black letters on white surface, 3 lines max, specify legend, add suffix NP. Shunt trip (specify voltage), add suffix ST. Under voltage release (specify voltage), add suffix UV. For +50 C (+1 F) breaker rating, add suffix V. For 65,000 AIC rating, contact your local sales representative. NEC Certifications and Compliances UL Standard: UL 103 UL Listed: E84577 CSA Standard: C. No. 5, C. No. 30, C. No. 5.1 CSA Certified: 05308 GE is a registered trademark of General Electric Company. Square D is a registered trademark of Schneider Electric. Cutler-Hammer is a registered trademark of Eaton Corporation. Visit our website at www.emerson.com or contact us at (800) 61-1506. March 017
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Catalog Numbering Guide N E A B 1 3 15 C O-Z/Gedney NE Series Enclosure Type: B - Bolted Line Voltage: - 40 4-480 6-600 Suffix for Other Options/Features: Must be listed in alphanumeric sequence (See Options) E - Explosionproof Breaker Frame: 1-100-150AF - 50AF 4-400AF 6-600AF 8-800AF 1-100AF Breaker Trip: 15-15AT 0-0AT 5-5AT 30-30AT 35-35AT 40-40AT 50-50AT 60-60AT 70-70AT 80-80AT 90-90AT 10-100AT 1-15AT 15-150AT 17-175AT 0-00AT - 5AT 5-50AT 30-300AT 35-350AT 40-400AT 45-450AT 50-500AT 60-600AT 70-700AT 80-800AT 10-1000AT 1-100AT Enclosure Size: A - 15-50 AT B - 60-100AT C - 15-150AT E - 175-5AT F - 50-400AT D - 400-600AT L - 700-800AT G - 1000-100AT Number of Poles: 3-3 Pole 4-4 Pole (Contact your local representative) Indicate Breaker Manufacturer: C - Cutler-Hammer (standard) S - Square D G - GE To complete the catalog number please add the appropriate suffix for other options/features. These suffixes can be found in the modifications table in this section. Visit our website at www.emerson.com or contact us at (800) 61-1506. March 017
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Circuit Breaker Interrupting Ratings (Symmetrical RMS Amps) Breaker Type 40 Vac 480 Vac 600 Vac Cutler-Hammer EHD 18,000 14,000 FD 65,000 35,000 18,000 HFD 100,000 65,000 5,000 JD 65,000 35,000 18,000 HJD 100,000 65,000 5,000 KD 65,000 35,000 5,000 HKD 100,000 65,000 35,000 LD 65,000 35,000,000 HLD 100,000 65,000 35,000 MDL 65,000 50,000 5,000 HMDL 100,000 65,000 35,000 ND 65,000 50,000 5,000 HND 100,000 65,000 35,000 GE TED 18,000 18,000 14,000 THED 65,000 5,000 18,000 TFK 5,000,000 18,000 THFK 65,000 5,000 18,000 TJK4 4,000 30,000,000 THJK4 65,000 35,000 5,000 TJK6 4,000 30,000,000 THJK6 65,000 35,000 5,000 TKM8 4,000 30,000,000 THKM8 65,000 35,000 5,000 TKM1 4,000 30,000,000 THKM1 65,000 35,000 5,000 GE is a registered trademark of General Electric Company. Cutler-Hammer is a registered trademark of Eaton Corporation. Visit our website at www.emerson.com or contact us at (800) 61-1506. March 017
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Breaker Frame Size 100 150 100 150 150 Breaker Type/ Interrupting Capacity EHD 18,000 AIC @ 40 Vac FD 65,000 AIC @ 40 Vac EHD 14,000 AIC FD 35,000 AIC FD 18,000 AIC Volts 480 Vac, 15/50 Vdc 15/50 Vdc 480 Vac, 15/50 Vdc 15/50 Vdc 15/50 Vdc Amp Catalog Numbers Rating -Pole 3-Pole 15 NEAB115C NEAB1315C 0 NEAB10C NEAB130C 5 NEAB15C NEAB135C 30 NEAB130C NEAB1330C 35 NEAB135C NEAB1335C 40 NEAB140C NEAB1340C 50 NEAB150C NEAB1350C 60 NEBB160C NEBB1360C 70 NEBB170C NEBB1370C 80 NEBB180C NEBB1380C 90 NEBB190C NEBB1390C 100 NEBB110C NEBB1310C 15 NECB11C NECB131C 150 NECB115C NECB1315C 15 NEAB1415C NEAB13415C 0 NEAB140C NEAB1340C 5 NEAB145C NEAB1345C 30 NEAB1430C NEAB13430C 35 NEAB1435C NEAB13435C 40 NEAB1440C NEAB13440C 50 NEAB1450C NEAB13450C 60 NEBB1460C NEBB13460C 70 NEBB1470C NEBB13470C 80 NEBB1480C NEBB13480C 90 NEBB1490C NEBB13490C 100 NEBB1410C NEBB13410C 15 NECB141C NECB1341C 150 NECB1415C NECB13415C 15 NEAB1615C NEAB13615C 0 NEAB160C NEAB1360C 5 NEAB165C NEAB1365C 30 NEAB1630C NEAB13630C 35 NEAB1635C NEAB13635C 40 NEAB1640C NEAB13640C 50 NEAB1650C NEAB13650C 60 NEBB1660C NEBB13660C 70 NEBB1670C NEBB13670C 80 NEBB1680C NEBB13680C 90 NEBB1690C NEBB13690C 100 NEBB1610C NEBB13610C 15 NECB161C NECB1361C 150 NECB1615C NECB13615C Standard Conduit Outlets (Inches) 1-1/ -1/ 1-1/ -1/ 1-1/ -1/ For higher interrupting capacities, contact your local representative. Cutler-Hammer breaker provided as standard. For GE breaker change C to G; For Square D breaker change C to S. To complete the catalog number please add the appropriate suffix for other options/features. These suffixes can be found under Options. Visit our website at www.emerson.com or contact us at (800) 61-1506. March 017
- and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Breaker Frame Size 50 400 600 800 100 Breaker Type/ Interrupting Capacity JD 18,000 AIC JD 35,000 AIC KD 5,000 AIC KD 35,000 AIC LD 5,000 AIC LD 35,000 AIC MDL 5,000 AIC MDL 50,000 AIC MDL 5,000 AIC MDL 50,000 AIC Volts 15/50 Vdc 15/50 Vdc 15/50 Vdc 15/50 Vdc 15/50 Vdc Amp Catalog Numbers Rating -Pole 3-Pole 70 NEEB670C NEEB3670C 90 NEEB690C NEEB3690C 100 NEEB610C NEEB3610C 15 NEEB61C NEEB361C 175 NEEB617C NEEB3617C 00 NEEB60C NEEB360C 5 NEEB6C NEEB36C Standard Conduit Outlets (Inches) 50 NEFB65C NEFB365C 4 15 NEFB461C NEFB4361C 175 NEFB4617C NEFB43617C 00 NEFB460C NEFB4360C 5 NEFB46C NEFB436C 50 NEFB465C NEFB4365C 300 NEFB4630C NEFB43630C 350 NEFB4635C NEFB43635C 400 NEFB4640C NEFB43640C 450 NEDB6645C NEDB63645C 500 NEDB6650C NEDB63650C 600 NEDB6660C NEDB63660C 300 NELB8630C NELB83630C 350 NELB8635C NELB83635C 400 NELB8640C NELB83640C 450 NELB8645C NELB83645C 500 NELB8650C NELB83650C 600 NELB8660C NELB83660C 700 NELB8670C NELB83670C 800 NELB8680C NELB83680C 600 NEGB1660C NEGB13660C 800 NEGB1680C NEGB13680C 1000 NEGB1610C NEGB13610C 100 NEGB161C NEGB1361C 3 4 4 () 4 () 4 To complete the catalog number please add the appropriate suffix for other options/features. These suffixes can be found under Options. For higher interrupting capacities, contact your local representative. Cutler-Hammer breaker provided as standard. For GE breaker change C to G; For Square D breaker change C to S. Visit our website at www.emerson.com or contact us at (800) 61-1506. March 017
NE Bolted Circuit Breaker Enclosure - and 3-Pole, Non-Interchangeable Trip. Bolted Enclosure Type. Class I, Division 1 and, Groups B, C, D Class II, Division 1 and, Groups E, F, G Dimensions in Millimeters (Inches) Enclosure Only Enclosure Size Catalog Number Dia. Number A AEAB 1 B AEBB 1 C AECB 1 E AEEB 1 F AEFB-50 1 F AEFB-400 D AEDB L AELB 3 G AEGB 4 Dimensions in Millimeters (Inches) Mounting Inside Outside A B J C D E F G H 139.7 (5.50) 15.4 (6.00) 60.3 (10.5) 15.9 (8.50) 41.3 (9.50) 41.3 (9.50) 409.7 (16.13) 543.1 (1.38) 333.5 (13.13) 457. (18.00) 574.8 (.63) 689.1 (7.13) 69.1 (7.5) 69.1 (7.5) 1035.0 (40.75) 115.6 (45.38) 170.0 (50.00) 358.9 (14.13) 78.6 (19.00) 155.7 (6.13) 165.1 (6.50) 89.0 (11.38) 85.7 (11.5) 85.7 (11.5) 85.7 (11.5) 457. (18.00) 473. (18.63) 508.0 (0.00) 73.0 (10.75) 508.0 (0.00) 758.9 (9.88) 758.9 (9.88) 758.9 (9.88) 1079.5 (4.50) 1073.1 (4.5) 154.0 (60.00) 133.3 (5.5) 139.7 (5.50) 16.0 (6.38) 183.8 (7.63) 04.7 (8.06) 04.7 (8.06) 193.8 (7.63) 15.9 (8.50) 54.0 (10.00) 70.0 (10.63) 79.4 (11.00) 416.0 (16.38) 416.0 (16.38) 346. (13.63) 606.5 (3.88) 635.0 (5.00) 387.3 (15.5) 50.7 (0.50) 638.3 (5.13) 749.3 (9.50) 889.0 (35.00) 889.0 (35.00) 96.1 (37.88) 116.1 (47.88) 1651 (65.00) 4.5 (8.84) 7.8 (8.97) 43.5 (9.59) 311.9 (1.8) 313.4 (1.34) 30.8 (1.63) 35.3 (1.81) 361.9 (14.5) 534.0 (1.38) Number of Outlets 4 6 Dimension mm (in) K 50.8 (.00) 58.6 (.31) 88.9 (3.50) 101.6 (4.00) 106.4 (4.19) 106.4 (4.19) 109.4 (4.31) 17.0 (5.00) 111. (4.38) Approximate Weight kgs (lbs) 17.4 (38) 5.85 (57) 47.17 (104) 65.77 (145) 77.11 (170) 77.11 (170) 103.4 (8) 190.06 (419) 57.19 (567) Visit our website at www.emerson.com or contact us at (800) 61-1506. March 017