Unrestricted. Air Core Reactor Applications Current Limiting Reactors

Similar documents
ABB POWER SYSTEMS CONSULTING

Final Draft Report. Assessment Summary. Hydro One Networks Inc. Longlac TS: Refurbish 115/44 kv, 25/33/ General Description

Study of Fault Clearing by A Circuit Breaker In Presence of A Shunt Capacitor Bank

Review paper on Fault analysis and its Limiting Techniques.

AIR CORE REACTORS. Phoenix Electric Corporation

A system fault contribution of 750 mva shall be used when determining the required interrupting rating for unit substation equipment.

Wheeler Ridge Junction Substation Project Description and Functional Specifications for Competitive Solicitation

Independent Testing Laboratory for High Voltage Equipment

Noxon Rapids Reactor Project. Scott Wilson June 9, 2016 Tracy Rolstad

CHAPTER 4 PROTECTION REQUIREMENTS

Nissin s Products for Electric Railway System

Feasibility Study. Shaw Environmental, Inc. 12MW Landfill Gas Generation Interconnection. J.E.D. Solid Waste Management Facility. Holopaw Substation

Medium Voltage Metal-Enclosed Switches

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Interconnected Electric System Protection Requirements

SOFE

SWITCHGEAR DIVISION PRODUCT PROFILES

Increasing Wanzhou Power Transfer Capability by 550kV Fixed Series Capacitor FSC Fengjie

BHARAT ALUMINIUM COMPANY LTD. SPECIFICATIONS FOR SYNCHRONOUS GENERATOR GENERAL Make : Jinan Power Equipment Factory Type : WX2

Energy Transmission & Distribution Services - Italy. SVEPPI laboratory...our services for your success. Answers for energy.

HARMONIC FILTER REACTOR

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group April 17, 2009 Slide 1

APPENDIX E: Project Need and Description

Development and Operational Advantages of a Solid State Circuit Breaker with Current Limiting

Overview Gas Insulated Switchgear Modular and flexible, kV. ABB Group May 15, 2013 Slide 1

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

Modular Capacitor Systems Reactive Compen. sation. Copyright 2002 ABB. All rights reserved.

TRANSMISSION PLANNING CRITERIA

C1000 Series Automatic Cap Bank

Medium Voltage Metal-Enclosed Switches

EH2741 Communication and Control in Electric Power Systems Lecture 3. Lars Nordström Course map

EL PASO ELECTRIC COMPANY SHORT CIRCUIT ANALYSIS FOR XXX S PROPOSED GENERATION INTERCONNECTION

MODELLING OF 25 kv ELECTRIC RAILWAY SYSTEM IN EMTP-RV

An Alternative to Reduce Medium-Voltage Transient Recovery Voltage Peaks

Interconnection Feasibility Study Report GIP-222-FEAS-R3

PID 274 Feasibility Study Report 13.7 MW Distribution Inter-Connection Buras Substation

Interconnection Feasibility Study Report GIP-226-FEAS-R3

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

CIS-IEEE 2017 Conference Renewable Energy Session Renewable Energy s Impact of Power Systems

Dynamic Control of Grid Assets

PJM Generator Interconnection R81 Emilie (Fords Mill) MW Impact Study Re-Study

Chapter 6 Generator-Voltage System

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

DESIGN CONSIDERATIONS FOR APPLICATION OF SHUNT CAPACITORS IN HEAVY HATER PLANT (TUTICORIN)

6545(Print), ISSN (Online) Volume 4, Issue 2, March April (2013), IAEME & TECHNOLOGY (IJEET)

Reactive Power Compensation using 12 MVA Capacitor Bank in 132/33 KV Distribution Substation

ABB n.v Power Quality in LV installations

APPENDIX E: Project Need and Description

EMPAC Metal enclosed capacitor bank for wind applications

Medium Voltage Metal Enclosed Thyristor Switched Harmonic Filter Banks

Maximum temp. rise in oil by 40 thermometer above design ambient (deg C) specified time Short circuit rating (Sec) for As per IS 2026

New 115 kv Disconnect Switches at Bloomsburg MTS

Safe, fast HV circuit breaker testing with DualGround technology

Electrical Power Electric power electrical electric power Electric power electric electric

Southern Company Interconnection Process. Dexter Lewis Research Engineer Research and Technology Management

8DJ. Maintenance-free for lifetime

XXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXXX TRANSMISSION AND FACILITIES STUDY. Short Circuit Analysis

Medium Voltage. Power Factor Correction Reactive Compensation Harmonic Filters. Electrical Power Quality Management at its best.

Long distance bulk transmission

43-SDMS-04 REV. 00 SPECIFICATIONS FOR

16.13 Unit Substation to 15kV Construction Standards Page 1 of 7

15 Nelson-Marlborough Regional Plan

Final Written Examination.

AIR INSULATED METAL ENCLOSED SWITCHGEAR AND CONTROLGEAR

Shunt Capacitor Bank Protection in UHV Pilot Project. Qing Tian

System Impact Study Report

Power System HVDC Applications

Experience on Technical Solutions for Grid Integration of Offshore Windfarms

Power Systems Trainer

XXXXXXXXXXXXXXXXXXXX GENERATION INTERCONNECTION FACILITIES STUDY SHORT CIRCUIT ANALYSIS FOR PROPOSED GENERATION AT NEWMAN 115 kv BUS

Bharat Heavy Electricals Limited (High Pressure Boiler Plant) Tiruchirappalli , TAMIL NADU, INDIA CAPITAL EQUIPMENT / MATERIALS MANAGEMENT

CUSTOMER/ TWIN ARROWS PROJECT

ECE 421 Project 1, Group 3 HVDC. Brian Beilstein, Robert Germick, James Haney, Alexander Joss, Matt Murphy, Shutang You

Chapter 3.1: Electrical System

Targeted Application of STATCOM Technology in the Distribution Zone

Form G5-1 PACIFIC GAS AND ELECTRIC COMPANY GENERATION PRE-PARALLEL INSPECTION

Interconnection Feasibility Study Report GIP-157-FEAS-R2

Type SDV6 distribution circuit breaker. Top performance - proven reliability. Answers for energy.

SINAMICS SM150. Siemens product performance features. Competitor product profile. Components. Power, transport units. Service friendliness

Power Quality. Power Factor Wiring and Service. Background. Introduction. bchydro.com

Welcome. Power Survey International

Modular contactors and relays

THE PROTECTION OF INDUSTRIAL CAPACITOR BANKS BY CURRENT LIMITING FUSES. By M.J. Smart and B. Wadcock

MESG 12 / 17.5 / 24 / 36 KV

Power Voltage Transformers for Air Insulated Substations

Renewable and Distributed Energy Resource Technologies

CONNECTION ASSESSMENT & APPROVAL PROCESS. Cardinal Substation Modification of 115kV Substation

Relative Power Factor Correction costs

Auxiliary Relay (7PJ11) and Trip Relay (7PJ12)

High Voltage Surge Arresters Buyer s Guide Section Transmission Line Arrester PEXLINK

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

132/11 kv, 25 MVA MOBILE SUBSTATION

Interconnection Feasibility Study Report GIP-IR373-FEAS-R1

MIPSYCON 2014 Can a Grid be Smart without Communications? A Look at an Integrated Volt Var Control (IVVC) Implementation

First Applications on AltaLink s Network. Roggero Ciofani, P. Eng. Colin Clark, P. Eng.

Magnetically Controlled Reactors Enhance Transmission Capability & Save Energy Especially in Compact Increased Surge-Impedance- Loading Power Lines

Fall 1997 EE361: MIDTERM EXAM 2. This exam is open book and closed notes. Be sure to show all work clearly.

SF6 GAS INSULATED METAL ENCLOSED SWITCHGEAR (GIS)

APPENDIX C FACILITY ILLUSTRATION

Renewable Energy Systems 14

Superconducting Cable Systems for Urban Areas AmpaCity Project - Germany

Transcription:

Unrestricted Air Core Reactor Applications Current Limiting Reactors

Faults on Electrical System - Basic Concepts Three major concerns arise from this scenario: 1- The mechanical stresses on the transformer windings are proportional to the square of the current ( F ~ I 2 ) 2 - The ability of the equipment to withstand the fault current without damage 3 - Equipment wear-out

Reactor as current limiting device Used to limit fault currents to values lower than would otherwise exist; Can be applied in a variety of different configurations at: Distribution Voltages Neutral Grounding Reactors Feeder Reactors Bus Tie Reactors Transformer Secondary Reactors

Reactor as current limiting device Used to limit fault currents to values lower than would otherwise exist; Can be applied in a variety of different configurations at: Transmission Voltages Bus Tie Reactors Line Reactors

The Impact of Current Limiting Reactors 1. With No Reactors N.O. Tie N.C. Tie HV Bus 3 [ka] 14.4 25.4 SLG[kA] 15.7 28.6 2. Add Series Reactors : 13.8 kv- 300 A, 2.9%, 0.77 ohms 3 [ka] 6.1 7.4 SLG[kA] 6.2 7.6 3. Add NGR Reactors @ both Transformers: 13.8 kv-300 A, 0.77 ohms 3 [ka] 14.4 25.4 SLG[kA] 6.2 12 50MVA 12.5% N.C. / N.O. 13.8 kv Distribution Circuits HV Bus 50MVA 12.5% N.C. / N.O. 13.8 kv Distribution Circuits HV Bus 50MVA 12.5% N.C. / N.O. 13.8 kv Distribution Circuits

Applying Current Limiting Reactors Current Limiting Reactors Concerns Reactor losses Negligible Voltage regulation TRV l X R Negligible at a Normal Power Factor If Any Issue, Can be Resolved Very Easily Can be resolved by further reduction of Short Circuit current with larger reactor

Eletronorte (Brazil) : Tucurui Generating Station (500kV)

Eletronorte 500 kv CLR A power plant with two power houses in one dam; Power House #1: Completed in 1995; 12 generators of 350 MVA each (4,200 MVA); Power House #2: Completed in 2006; 11 generators of 390 MVA each (4,290 MVA); Each power house has its own air insulated substation which, allowing for system flexibility, were to be operated in parallel; This would have caused the short circuit capability of the equipment associated with the original substation (40 ka), to be exceeded.

Eletronorte 500 kv CLR Options 1. Operate two stations independently 1.Reduced Reliability 2. Makes Operation difficult 2. Change all the equipment in the TUC #1 Very Expensive Extensive down time (hence not practical) 3. Use a current limiting reactor

Eletronorte 500 kv CLR To achieve parallel operation of the two substations without exceeding any rating of existing equipment, Eletronorte selected to install bus tie reactors connecting the two substations. The following reactor characteristics requirements were specified: - Rated Voltage : 550/ 3 kv - Rated Current: 2,600 A - Rated Short Circuit: 10 ka / 27 ka (1.0 Sec.) - Rated Reactance: 20 Ohms - Rated Power: 135 MVA / Phase - Min. Q factor: 400 Due to the importance and high profile of the installation, Eletronorte also specified the following: - System Reliability: 100 % - System availability: 100 % - Max. RRTRV: 5.0 kv/ Sec (on any breaker, for any fault) - Turn Key installation in 240 days after signing of contract

Eletronorte 500 kv CLR Simplified One Line Diagram Tucurui - Stage 1 : 4,200 MVA 12 X 350 MVA Tucurui - Stage 2 : 4,290 MVA 11 X 390 MVA 500 kv 500 kv 500 kv 500 kv CLR 69 kv Supply Maraba 1 Maraba 2 V. Conde 1 Maraba 3 Maraba 4 V. Conde 2 230 kv Supply

Eletronorte 500 kv CLR Reactor in any of the three phases can be be replaced by the reserve one. TUC # 1 TUC # 2 A1 B1 C1 C2 B2 A2

Eletronorte 500 kv CLR TRV Protection Scheme TRV Capacitor TRV Capacitor 2,600 Amp, 20 Ohm TRV Capacitor Taps for capacitor monitoring & harmonic measurements

Eletronorte 500 kv CLR 22 nf CC (across reactor) 14 nf (line to ground)

11.5 m Current Limiting Reactors Eletronorte 500 kv CLR System Voltage : 550 kv Impedance : 20 Rated current : 2600 A Rated Power: 135 MVA / Phase Thermal Short Circuit: 10 KA / 1 Sec. Mechanical Peak: 27 KA BIL / SIL : 1550 / 1180 kv Losses / Efficiency : 280 kw / 99.79 % RRTRV control: < 5.0 kv/ sec Weight : 32,000 kg (2 coils) (insulator excluded) Estimated Savings: US$ 100 M

East China Power Si Jing Station (500kV)

Shanghai s 500 kv System - Basic Single Line Diagram XUHANG 500 kv NANQIAO 500 kv EHV CLR 500 kv 14 Ω 2400 A HUANGDU 500 kv SIJING 500 kv SHIPAI 500 kv EHV CLR 500 kv 14 Ω 2400 A HVDC From 3 Gorges (Future) HUXI 500 kv

Si Jing 500 kv CLR TRV Protection Diagram TEHCP 500S C = 2 X 14.000 pf Line L = 53.05 mh Station TEHCP 500H C= 2 X 16.000 pf

Si Jing 500 kv CLR

Si Jing 500 kv CLR Rated System Voltage Rated Frequency Rated Current Rated Inductance / Impedance Rated Power 2400 A 500 kv 50 Hz 80.64 MVAr 44.56 mh / 14 Ω Losses / Efficiency : 128 kw / 99.8 % Rated Short Circuit current (3 Secs.) Peak Short Circuit Current BIL across Coil / Insulator SIL across Coil / Insulator Capacitance to ground (line side) Capacitance to ground (Station side) Capacitance across coil 40 KA TRV Protection 16 KA 1550 kv 1175 / 1300 kv NA 2 * 14 nf 2 * 16 nf

Furnas 345kV - Brazil

Mogi das Cruzes SE Furnas 345 kv CLR Installation Characteristics - Rated Voltage : 345 kv - Rated Current : 2,100 A - Inductance: 24.05 mh - Rated Power: 40 MVA / phase - BIL / SIL: 1,300 / 850 kv - Losses / Eff.: 133 kw / 99.7% - TRV control: Not required - Weight = 28,600 lbs. (13,000 kg) - Operational Since Dec. 1998 Estimated Savings:> US$ 10 M (only equipment)

KEPCO 345 kv CLR South Korea

Korea Electric Power 345 kv CLR Buk-Busan Impedance = 5.9 System Voltage = 345 kv Rated current = 2200 A No TRV Protection Required