TRANSFORMER RECTIFIER

Similar documents
Ordering Information. Switching Power Supply S82F. Industrial-Grade Power Supply for General or Peak Load Applications SWITCHING POWER SUPPLIES

Technical Data. Low Voltage Regulation System LVRSys. Flexible solution for power utilities. Voltage stabilization for industrial grids

On Grid Wind Turbine(wind solar hybrid)controller

ROBUST LED DRIVERS. EasyLine Industry. EasyLine INDUSTRY , , , , , , ,

PRO POWER 2 0 A L I T H I U M B AT T E RY C H A R G E R M O D E L : P P - L B C V E R S I O N : V 1. 0

Switching Power Supply

TL-W. Standard Flat Sensors in Many Different Variations. Flat Inductive Proximity Sensor. Ordering Information

LINEAR LED DRIVERS. ComfortLine Selectable Current (Output Terminal) ComfortLine SELECTABLE CURRENT (OUTPUT TERMINAL)

Medium Voltage Metal-Enclosed Switches

Medium Voltage Metal-Enclosed Switches

2 SLR Series Line Reactors... 50

AC/DC Arc Furnace and Ladle Furnace Transformers

JUNCTION BOX FOR CATHODIC PROTECTION

User Manual of Battery Charger

EMPAC Metal enclosed capacitor bank for wind applications

Vacuum Circuit Breaker VS1

ZX2 Gas-insulated medium voltage switchgear

Key features. DESIGNS: - Conservator type - Hermetically sealed

55185 EMERGENCY PACK FOR LED PANEL TECHNICAL DATA SHEET

E2E2. Proximity Sensor with a Long Screw Length. Long-barrel Inductive Proximity Sensor. Ordering Information. Sensors DC 2-Wire Models

Inductive Proximity Sensor

MESG 12 / 17.5 / 24 / 36 KV

AME. Rectifier - Battery charger. Industrial applications: Key features:

SLOVAK UNIVERSITY OF TECHNOLOGY Faculty of Material Science and Technology in Trnava ELECTRICAL ENGINEERING AND ELECTRONICS.

Metal-Enclosed Switches. Medium Voltage. Medium Voltage Metal-Enclosed Switches Contents

Differential Pressure Transmitter

Section S7 - DC and AC auxiliary services installations

Power Voltage Transformers for Air Insulated Substations

ATevo SERIES BATTERY CHARGER

E2EZ-X2D1-N E2EZ-X2D2-N

GX-5SU(B) is just 5.4 mm 0.213in in diameter, the smallest in existing DC two-wire sensors. It saves you space.

AT EVO SERIES BATTERY CHARGER

132/11 kv, 25 MVA MOBILE SUBSTATION

Power consumption Wire/transformer sizing. Motor. Spring return. Motor. Spring return. EMC Low voltage directive

Industrial Chargers and

CENTAURI ENERGY SERVER TECHNICAL DATA kw POWER

ABB central inverters ULTRA-750/1100/ kW to 1560kW

LEAB ChAmp. Product Specification. Idavägen Växjö Tel Fax Art 00438XX 00338XX

3.6 Kwp Solar system Supply, Installation, Commissioning & Maintenance of Solar Systems to YEMAC office in HADDA street, Sana a city

SMPPT. Solar Charge Controller with Maximum Power Point Tracking. Installation & Operation Manual

ALR output Powerfull PROGRAMMABLE POWER SUPPLY 640 WATTS 0-32V 0-20A POWERFUL. Specifications

HGM501 Gen-set Controller USER MANUAL. Smartgen Technology

Features. 2-wire type available. Max. operation distance: 1.5 mm 0.06 in (Stable sensing range 0 to 1.2 mm 0.05 in)

User Manual. Solar Charge Controller 3KW

General. Main electric circuits Fuses compartment Operating mechanisms Cables connection compartment

Medium voltage products UniSec DY800 New 24 kv air-insulated medium voltage switchgear to e-distribuzione specifications

D Series: UPS UPTO - 300KVA - Three / Three Phase

Features. Description. Table of Contents

Basic Switch Style Inductive Prox TL-M. Ordering Information. General-purpose Inductive Prox in a Basic Switch Housing

MV Air Insulated Switchgear TAP17. Technical Data TGOOD

LS0512R Solar Light Controller

AMS. Rectifier - Battery charger. Industrial applications: Key features: VRLA batteries with output voltage from 24, 48, 110, 220 Vdc up to 30A

EVO AT SERIES BATTERY CHARGER

EVO SERIES BATTERY CHARGER SERIES BATTERY CHARGER

DC/DC converter SINGLE OUTPUT

2.5 mm. (0.10 in) E2S -Q25 E2S -Q26. Output configuration. 2.5 mm. End face E2S -W15 E2S -W16 End face PNP

LS0512 Solar Charge Controller

Type SIMOPRIME A4, up to 24 kv, Air-Insulated Medium-Voltage Switchgear

8DJ. Maintenance-free for lifetime

AT SERIES EVO BATTERY CHARGER

Inductive voltage transformers

Inductive voltage transformers

SWITCHCRAFT. Switchcraft Europe GmbH SWITCHCRAFT

INTER PLANT STANDARD STEEL INDUSTRY SPECIFICATION FOR STATIC EXCITATION CONVERTORS FOR SYNCHRONOUS MOTORS (FIRST REVISION)

AT30 SERIES BATTERY CHARGER

Ordering Information. Long Barrel Inductive Prox. E2E2 2-Wire DC. Reduce Wiring to Control Devices with 2-Wire Inductive Prox Sensors

(DC/DC) SERIES to 96.5% (typical) Product Lineup. Ordering Information. Features. General Description. Super high efficiency

Indoor Integrated Power System

Current accuracy class. Sensor principles

LED Driver Linear / area fixed output industry. Driver LCI 65W 150mA 400mA TOP INDUSTRY sl TOP series

Power Conversion Systems 2005/2006. Schaefer the Power to make it happen.

Analog Input Terminal

Owner s Manual. DC-DC Step Down Converter

SSL-1500 (12V/24V/48V) / SSL-3000 (12V/24V/48V)

DART Charger Product Description, Information and Specification

User s Manual. Wind/Solar Hybrid Street Light Controller. Please Read This User Manual Carefully Prior to. Installation and Operation of This Product.

USER MANUAL. Insulation Tester + DMM. Model MG320

GE Consumer & Industrial Power Protection. New. SecoGear kV Metal-clad Switchgear. GE imagination at work

LED Driver Linear / area fixed output industry. Driver LCI 100W 350mA 900mA TOP INDUSTRY sl TOP series

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

Technical Data. Windy Boy 6000US. Windy Boy 5000US. Windy Boy 7000US

Film Capacitors Power Factor Correction

User Manual. UPower Series. Inverter/charger

Solar Inverter Manual

Proximity Sensor. Shield Size Sensing distance Output configuration Models Shielded M12 3 mm NO E2EQ-X3D1 E2EQ-X7D1 M30 10 mm E2EQ-X10D1

Ordering Information. Long Barrel Inductive Prox E2E2 2-WIRE AC. Rugged Inductive Prox Sensors Meet IP67 Requirements

Supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p) 10% max. 100 to 220 VAC (90 to 250 VAC), 50/60 Hz

WARNING WARNING. ECM3000 Control Motor User's Manual CAUTION NOTICE SAFETY PRECAUTIONS

User Manual Solar Charge Controller 3KW

40W POWER LINE COMMUNICATIONS SMART LED POWER DRIVER

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 2

Compact Integrated Distribution Substation (CIDS)

GL-6 SERIES. Miniature Inductive Proximity Sensor. High Performance in Surprisingly Small Body. Marked. Extremely Small.

Horizontal Circuit Switchers

Horizontal Circuit Switchers

output Output Voltage min (ma)

1. Electronic Stabilizer and Technical Development. 2. Electronic Stabilizer General

Anti-spatter Inductive Prox E2EQ. Ordering Information. Weld-Sputter Resistant DC 2-Wire Cylindrical Sensors. H Rugged fluoroplastic coated brass

PROJOY PORTFOLIO PROJOY ELECTRIC CO., LTD

Power Supplies. 11/2 Introduction

Transcription:

TRANSFORMER RECTIFIER voltage from the commercial electrical power grid or an engine-generator. A transformer with tap adjustments in the secondary side provides a method to reduce and adjust the output voltage level and to isolate the DC circuit from the input power system. A rectifying circuit next converts the adjusted AC voltage to produce a DC voltage output. > AC Supply > Circuit Breaker > Transformer > Rectifying Elements > Meters > DC Output Terminals > Fuses > Surge Protection Ningbo Yuxi acquire an electronic manufacture-changlian with more than 40years of history in 2014, this factory Sinopec is still in operating in Ningbo. This acquisition enable Yuxi have the full capability to supply high end electronic Product Line: > YX-DJ-1 Air Cooled Type > YX-DJ-2 Oil Cooled Type > YX-FPS-1 Explosion Proof Type > YX-HPS-1B HFS Type > YX-SFS-1 Solar Type 46

Product Line: YX - DJ - 1 switching function of operation mode, and function of anti-jamming and anti-lightning to increase reliability greatly. The TR has adopted key-press operation.multimeters can be shown by multiple digital meters at the same time. Operation and control are simple and intuitive. The TR can be connected with computer to transmit parameters and working state remotely and control operation mode and potential given value remotely, which has realized intelligent management. 47

AC Input DC Output Current Current Limiting Constant Current DC Output Voltage Set Potential Precision of Constant Potential Precision of Constant Current Input Impedance Working Style Cooling Ripple Fuses Control Meters Oil Terminals Resist of AC Interference Enclosure Protection Dimension (approx.) Weight (approx.) Ambient temperature range Relative Humidity Single phase AC220V±10% or Three phase 380V ±10% Frequency 47.5Hz~63Hz 0-50A 55-66A 0-50A 0-50V (continuous adjustment) 0 - ± 3V ± 5mV ± 1 % 10MΩ Constinuous Air Cooling 3 % Manual / Automatic Digital DC Ampere Meter, Digital DC Voltage Meter, Digital Potential Meter Oil level sensing device, Oil temperature indicator DC Output ( positive ) - 2nos DC Output ( negative ) - 2nos AC Input ( 220V ) - 1nos Reference electrode grounding - 1nos Reference electrode - 1nos 24V Outdoor type, Standard Painted Sheet Steel IP55 grade 1120 mm x 960 mm x 780 mm 80 kg - 30º to + 60º 90 % 48

Product Line: YX - DJ - 2 are equipped in control box. The degree of protection of enclosure is IP65. 49

AC Input DC Output Current Current Limiting Constant Current DC Output Voltage Set Potential Precision of Constant Potential Precision of Constant Current Input Impedance Dielectric Strenght Working Style Cooling Ripple Fuses Control Meters Oil Terminals Resist of AC Interference Enclosure Protection Dimension (approx.) Weight (approx.) Ambient temperature range Relative Humidity Three phase 380V ±10% Frequency 50 ± 10 % 102-110 % Rated Current Output 0-20V (continuous adjustment) 0 - ± 3V ± 5mV ± 1 % 10MΩ 1500V, 50Hz, 1 minute without breakdown Constinuous Oil Cooling 5 % Manual / Automatic Digital DC Ampere Meter, Digital DC Voltage Meter, Digital Potential Meter Oil level sensing device, Oil temperature indicator DC Output ( positive ) - 2nos DC Output ( negative ) - 2nos AC Input ( 380 V ) - 1nos Reference electrode grounding - 1nos Reference electrode - 1nos 24V Outdoor type, Standard Painted Sheet Steel IP65 grade 1120 mm x 960 mm x 780 mm 90 kg - 30º to + 60º 90 % 50

Product Line: YX - FPS - 1 directive. It is used in the place in which there are requirements for explosion-proof to protect metal structures and equipments, such as pipelines, cables, tanks and piers and so on by impressing current. 51

AC Input DC Output Current Current Limiting Constant Current DC Output Voltage Set Potential Precision of Constant Potential Precision of Constant Current Input Impedance Dielectric Strength Working Style Cooling Ripple Fuses Control Meters Oil Terminals Resist of AC Interference Enclosure Protection Dimension (approx.) Weight (approx.) Ambient temperature range Relative Humidity Three phase 380V ±10% Frequency 50 ± 10 % 102-110 % Rated Current Output 0-20V (continuous adjustment) 0 - ± 3V ± 5mV ± 1 % 10MΩ 1500V, 50Hz, 1 minute without breakdown Constinuous Oil Cooling 5 % Manual / Automatic Digital DC Ampere Meter, Digital DC Voltage Meter, Digital Potential Meter Oil level sensing device, Oil temperature indicator DC Output ( positive ) - 2nos DC Output ( negative ) - 2nos AC Input ( 380 V ) - 1nos Reference electrode grounding - 1nos Reference electrode - 1nos 24V Outdoor type, Explosion Proof Exod II BT3, IP65 1055 mm x 750 mm x 1645 mm 90 kg - 30º to + 60º 90 % 52