Rental Industry Safety Tester Safe Check 5s

Similar documents
Date received into service; / /.

INSTRUCTION MANUAL MARTINDALE CM52 CLAMP METER. ELECTRIC Trusted by professionals. Other products from Martindale:

KD1E Range Potential Indicators

Switching DC Power Supply

1.Safe testing IMPORTANT:

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Phase Sequence Tester

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Declaration of Conformity

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

TESTER SET SOCKET & VOLTAGE

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

INSP-3 Wiring Inspection Tester

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

R&S RT-ZC02 R&S RT-ZC03 AC/DC Current Probe User Manual

WARNING MANUFACTURER ASSUMES NO LIABILITY IF UNIT OPERATED IN AN UNSAFE MANNER.

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

PY-11 Voltage & Continuity Tester

DALI 650mA LED Driver

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

SafetyPAT Plus A B P/N:

Instruction Manual. Model 307A Analog Insulation & Continuity Meter

CONTACTS EGR VALVE TESTER 66248

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

INSTALLATION AND OPERATING INSTRUCTIONS OF THE INTERNATIONAL ISOBOX SERIES ISOLATION TRANSFORMERS.

KMP Insulation-Continuity Tester. Users Manual

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

650mA Phase Dimmable LED Driver

INSTALLATION GUIDE AND USER MANUAL

POWERED BY KT71 / Portable Appliance Tester. Instruction Manual

SimplePAT. Battery Powered Portable Appliance Tester. User Manual Issue 1.0

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

CONTACTS RELAY TESTER 66249

1 This instrument must only be used by a competent and trained person and operated in strict accordance with the instructions.

HST-BL-2830MS & HST-BL-2830MS-USA

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

1000mA - 650mA Phase Dimmable LED Driver

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Users Manual. Phase Rotation Indicator

Thyristor power controller TE10A. Burst-firing Single-cycle Advanced Single-cycle

PRM-2 PHASE SEQUENCE TESTER PRM-3 PHASE SEQUENCE & MOTOR ROTATION TESTER User s Manual

M OTO R. The electric motor. DC - direct current voltage.

GUIDELINES ON ELECTRICAL SAFETY AT WORKPLACES

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

Avoid nasty shocks Electrical safety for industry

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

INSTALLATION GUIDE AND USER MANUAL

DC POWER SUPPLY ALIMENTATION C.C.

BM kv Digital Insulation Tester USER MANUAL

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

DRAFT COPY, NOT FOR DISTRIBUTION

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

362 Clamp Meter. Users Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

User s Manual Power Supply. IM E 2nd Edition. Yokogawa Electric Corporation

MOTOR. The electric motor. DC - direct current voltage.

Models beginning with MO, MK, 7B, 6S, 6F or 5B. Product Description. Technical Specifications. Installation Instructions.

Non-Contact Phase Rotation Tester

1 INTRODUCTION SPECIFICATIONS Electrical Data General Data... 3

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

DC Master 24/ A

PHASE CONVERTERS OPERATING & MAINTENANCE INSTRUCTIONS. MODEL NO: PC40 and PC60. PART Nos:

USER MANUAL. Insulation Tester + DMM. Model MG320

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

MANUAL. Single charger

OPERATIONS AND APPLICATIONS MANUAL MODEL NUMBER PM6. 6 KV DC HIGH POTENTIAL TESTER WITH MEGOHMMETER Version 2.0

1 AMP CURRENT SOURCE

System 3 ZB1PS Device Chassis. Operator s Manual

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

Safety Precautions. Damages resulting from failure to observe these safety precautions are exempt from any legal claims whatever.

DKG-114 MANUAL AND REMOTE START UNIT

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

OPERATING INSTRUCTIONS

OPERATION & MAINTENANCE INSTRUCTIONS

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Automatic Battery Charger Switching mode with Micro-controlled Input: Vac / Output: 12Volt DC

SL101 Manual_SL101 User Manual 05/10/ :06 Page 1. Instruction Manual

EV100. Electric Vehicle Supply Equipment Tester. Operating Instructions

Multi-Mover Charger for model L25

For technical questions and replacement parts, please call

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Mini Multimeter with Non-Contact Voltage Detector (NCV)

BMRX Series Rotary Level Indicator

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Operators and Maintenance Manual. Display EEM MOT 01 FE02.02

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Technical Information Manual

OPERATION & MAINTENANCE INSTRUCTIONS

Electric Vehicle Charging Station

Transcription:

Rental Industry Safety Tester Safe Check 5s Feb 2006 2006 Clare Instruments Inc. Issue 2.0 Firmware Version : 1.2a

Limited Warranty & Limitation of Liability Clare Instruments Inc, guarantees this product for a period of one year. The period of warranty will be effective at the day of delivery. In order to ensure the continued performance of this product Clare recommends that this tester be serviced and calibrated on an annual basis, by Clare Instruments Inc. or any of Clare s authorised service center using Clare s approved parts and components. Any unauthorised modifications, tampering or physical damage sustained through negligent use or handling will void your warranty. Copyright 2005 All rights reserved. Nothing from this edition may be copied for reproduction, or made public in any form or manner, either electronically, mechanically, by photocopying, recording, or in any manner, without prior written consent from Clare Instruments Inc. This also applies to accompanying drawings and diagrams. Due to a policy of continuous development Clare Instruments Inc. reserves the right to alter the equipment specification and description outlined in this publication without prior notice and no part of this publication shall be deemed to be part of any contract for the equipment unless specifically referred to as an inclusion within such contract. i

Table of Contents BEFORE STARTING... 2 SAFETY... 3 WARNING... 4 INTRODUCING THE TESTER... 5 Introduction...5 Standard Accessories...5 Optional Accessories...5 SPECIFICATIONS... 6 Input Rating...6 Ground Bond Test...6 Short to Case Test...6 Short to Line Test...6 Leakage Test...6 PURPOSE OF THE TESTS... 7 Ground Bond Test...7 Short to Case Test...7 Short to Line Test...7 Leakage Test...7 Extension Cord Test...7 DEFINITIONS... 8 SWITCHING ON THE TESTER... 8 ii

SUPPLY POWER OUTLET FAULTS... 8 USING THE TESTER... 9 Testing Metal Case (Class 1) Products...9 Testing Double Insulated (Class 2) Products...9 Testing Extension Cords...10 RUN/LEAKAGE Test Self Test Facility...10 REPAIR AND CALIBRATION... 11 MAINTAINING THE TESTER... 12 Cleaning the Tester...12 User Maintenance...12 NOTES... 13 iii

DECLARATION OF CONFORMITY for the Clare Safe Check 5s Manufactured by: Seaward Electronic Ltd., Bracken Hill, Peterlee County Durham. SR8 2SW England Millennium Statement This product is Millennium compliant, and conforms fully to the document BSI DISC PD2000-1. Statement of Conformity Based on test results using appropriate standards, the product is in conformity with Electromagnetic Compatibility Directive 89/336/EEC and Low Voltage Directive 73/23/EEC Standards used: EN 61010-1 (2001) Safety Requirements for Electrical Equipment for Measurement, Control, and Laboratory Use. EN 61326: (1998) Class A. Electrical equipment for measurement, control and laboratory use EMC requirements. The tests have been performed in a typical configuration. This Conformity is indicated by the symbol, i.e. Conformité Européenne 1

Before Starting Upon receipt of your Tester: 1. Check that all the component parts are present: Safe Check 5s Tester Instruction Manual 2. Read the operating instructions fully before conducting any tests. 3. Contact Clare Instruments if you need information on training in Electrical Safety Testing. Courses can be arranged at Clare, or at the customer location. 4. Clare Instruments reserve the right to update the software in any instruments returned to them for repair or otherwise, without notifying the customer previously. Clare Instruments Inc. can be contacted at: Clare Instruments U.S. Inc, 6304 Benjamin Road, Suite 506, Tampa, Florida. Telephone: 813 886 2775 Fax: 813 886 2754 Email: usa@clareinstruments.com Internet: www.clareinstruments.com 2

Safety Note: Please read the following Safety Instructions before use! Safety Precautions The manual contains specific warning and caution statements. A Warning will identify the conditions and actions that pose hazard(s) to the user. A caution will identify the conditions and actions that may damage the Tester. Symbols used within this manual and on the Tester are shown below: Risk of electric shock Warning of potential hazard Conformité Européenne Use of the instrument in a manner not specified may impair safety. Read the following safety information carefully before attempting to operate the instrument. 3

Warning Due to the potential hazards associated with any electrical circuit it is important that the user is familiar with the instructions covering the capabilities and operation of this instrument. The user should ensure that all reasonable safety precautions are followed and if any doubt exists should seek advice before proceeding. This product is designed for use by suitably trained competent personnel and should be operated strictly in accordance with the instructions supplied. Failure to comply with these instructions may expose the user to electrical hazard. This Tester performs a number of electrical tests, which involve supply voltages and high currents. Never touch the Product being tested, or the test leads, whilst a test is in progress. Never remove the cover and touch any internal components whilst the tester is switched ON. Always check all test leads for signs of damage prior to use. Never use damaged or defective leads, to perform any test. Always ensure the power outlet to the Tester provides an adequate Ground connection. This manual contains information and warnings, which must be adhered to, to ensure operator safety during operation. It is essential that this manual be read fully before proceeding to test. Should the Tester behave abnormally do not continue with the testing. Disconnect immediately and contact Clare Instruments for servicing (see Chapter 5 - Maintaining the Tester). 4

Introducing the Tester Introduction The Clare Safe Check 5s Tester is a powerful tool to assist in the verification of the safety of electrical and electronic equipment. A range of tests are provided, with innovative features to aid difficult test situations, which allow testing of a wide variety of equipment. The Tester is designed to be easy to use, and also includes the following innovative features: Automatically checks supply power outlet for faults. Accurate Ground Bond, Short and Leakage Current measurements. Simple PASS FAIL indication. Automatic selection of correct tests. Supply Input 120V AC 60Hz (GROUNDED). 20 Amp thermal circuit breaker (located on the rear of the Tester) Versatile range of test outputs: Self test facility Standard Accessories Accessory Operating Manual Quick Reference Guide Part Number SC5s-OM SC5s-QR Optional Accessories Accessory Calibration Checkbox Product Number Labels (250) Pass Labels (500) Part Number SC5-CB CLARE-PNL CLARE-PL 5

Specifications Input Rating Supply Voltage... 120 Vac RMS Frequency... 50/60 Hz Fuse... 20 Amp thermal circuit breaker Ground Bond Test Test Voltage...6 Vac (Nominal) Test Current... 7A (Typical) Fail Level...500mΩ Short to Case Test Test Voltage...6 Vac (Nominal) Test Current... 20 μamps (Typical) Fail Level... 150kΩ Short to Line Test Test Voltage...6 Vac (Nominal) Test Current... 1 Amp (Typical) Fail Level...3Ω Leakage Test Test Voltage... 120 Vac Fail Leakage Current... 0.75 ma Accuracy Levels +/-10% at 22 C and 40% relative humidity. This product is IP40 rated. 6

Purpose of the Tests Your Safety Tester Ground Bond Test This test is to ensure the connection between the ground wire and ground pin in the power cord of the product and the metal casing are connected by a sufficiently low impedance. A test current is applied between the ground pin of the power cord and the ground clip. A high current is normally used to stress the connection to a fault condition. The length of the test is limited to prevent damage due to overheating. Short to Case Test A low voltage test to ensure there is no short present between the line conductor and the case. Short to Line Test A low voltage test to ensure there is no short between the line and neutral conductors. Leakage Test A supply voltage test to ensure there is no harmful leakage in the equipment under test. Extension Cord Test This test confirms the safety and integrity of 120V power cords. The cord test performs a ground bond test on the ground wire and then does continuity and polarity checks on the Line and Neutral conductors, between the plug and socket of the extension cord. 7

Definitions Equipment Under Test - the electrical / electronic apparatus (EUT) which is the subject of testing. Tester - the Clare Safe Check 5s tester. Un-powered Tests - the EUT is the subject of electrical tests using stimuli generated within the Tester. User - The test operative using the Tester to perform tests on an EUT Switching on the Tester Connect the power cord to a 120 Volt 60Hz Grounded supply. Switch on the Tester. The amber test indicators should illuminate. If the Green PASS and Red FAIL indicators illuminate there is a fault. Supply Power Outlet faults If a fault is detected, indicated by the Green PASS and Red FAIL indicators, switch the tester off immediately and correct the fault. Seek assistance if you are unsure how to proceed. The tester will not allow you to perform any tests while a fault is present. The type of fault can be determined by the buzzer. o Buzzer Continuous Mains power has been connected to the male test plug. Remove any power cords connected to the tests connectors o Short beeps (0.2s duration) Supply Ground fault. The installation ground has a fault. Consult a qualified electrician. o Long beeps (0.5s duration) Line/Neutral fault. The installation line and neutral connections are crossed. Consult a qualified electrician. 8

Using the Tester WARNING - do not touch or hold the EUT during testing. Ensure the EUT cannot move when under test. Testing Metal Case (Class 1) Products Before connecting to the Tester a visual inspection must be carried out to ensure the EUT has no loose cables on plugs or cable entries, and to verify the condition of the supply cord. Connect the EUT to the appropriate test output socket. Ensure the EUT is switched on and properly supported. Connect the ground clip to a metal part on the body of EUT. WARNING During LEAKAGE tests the product will be powered at line voltage and will operate. Make sure the ground clip is not connected to moving parts. Press and hold the TEST button to begin test sequence. If the TEST button is released at any time the sequence will be aborted. If any test fails all outputs are switched off and the FAIL indicator will flash for 3 seconds accompanied by the buzzer sounding. As each test is performed the indicator will flash. When a test is complete the next test in the sequence will start automatically. After the SHORT to LINE test has finished the LEAKAGE test will not start until the TEST button has been released and the RUN/LEAKAGE button has been pushed. Press and hold the RUN/LEAKAGE button to start the LEAKAGE test. If the RUN/LEAKAGE button is released at any time the test sequence will abort. WARNING During LEAKAGE tests hazardous voltages may be present. Do not touch the EUT during LEAKAGE tests. When all tests are successfully completed the PASS indicator will flash for 3 seconds. Testing Double Insulated (Class 2) Products Before connecting to the Tester a visual inspection must be made to ensure the EUT has no loose cables on plugs or entries, and to verify the condition of the supply cord. Connect the EUT to the appropriate test output socket. Ensure the EUT is switched on and properly supported. Connect the ground clip to body of EUT. 9

Press and hold the TEST button to begin. If the TEST button is released at any time the sequence will abort. If any test fails all outputs are switched off and the FAIL indicator will flash for 3 seconds accompanied by the buzzer. As the SHORT to LINE test is performed the indicator will flash. After the SHORT to LINE test has finished the LEAKAGE test will not start until the TEST button has been released and the RUN/LEAKAGE button has been pushed. Press and hold the RUN/LEAKAGE button to start the LEAKAGE test. If the RUN/LEAKAGE button is released at any time the test sequence will abort. WARNING During LEAKAGE tests hazardous voltages may be present. Do not touch the EUT during LEAKAGE tests. Testing Extension Cords Before connecting to the Tester a visual inspection must be made to ensure the EUT(in this case the extension cord set) has no loose cables on plugs or sockets, and to verify the condition of the supply cord. Connect the socket end of the EUT to the Tester output plug (male) and the plug end of the EUT to the appropriate test socket output. Press and hold the TEST button to begin the tests (three stages). If the TEST button is released at any time the sequence will abort. As the CORD TEST is performed the indicator will flash to indicate that the Ground bond test (1 st stage), then the continuity & polarity tests (2 nd stage), then the line/neutral short test (3 rd stage) are being performed respectively. If any test fails all outputs are switched off and the FAIL indicator will flash for 3 seconds accompanied by the buzzer. When all tests are successfully completed the PASS indicator will flash for 3 seconds. RUN/LEAKAGE Test Self Test Facility Ensure there are no EUTs connected to the tester. Select CLASS 2 Double Insulated using the rotary switch. Press and hold the TEST button to begin. If the TEST button is released at any time the sequence will abort. After the SHORT to LINE test has finished the LEAKAGE test will not start until the TEST button has been released and the RUN/LEAKAGE button has been pushed. 10

Before beginning the LEAKAGE test press the Leakage Self Test button on the rear of the tester Press and hold the RUN/LEAKAGE button to start the LEAKAGE test. If the RUN/LEAKAGE button is released at any time the test sequence will abort. The LEAKAGE test should fail Note: the Leakage Self Test button must be pressed for the full duration of the LEAKAGE test If the LEAKAGE test does not fail, contact Clare Instruments Inc. for service Repair and Calibration Please return with a detailed fault report to: Clare Instruments U.S. Inc, 6304 Benjamin Road, Suite 506, Tampa, Florida Telephone: 813 886 2775 Fax: 813 886 2754 Email: usa@clareinstruments.com Internet : www.clareinstruments.com 11

Maintaining the Tester Cleaning the Tester The Tester case can be cleaned with a damp cloth and a small amount of mild detergent. Prevent excessive moisture around the socket panel or at the rear of the unit. Do not allow liquids to ingress into the Tester, or around the socket panel. Do not use abrasives, solvents, or alcohol to clean. If any liquid is spilt onto the Tester case, the Tester should be returned for inspection, stating the cause of the defect. User Maintenance The Tester is a rugged quality instrument. However, care should always be taken when using, transporting and storing this type of equipment. Failure to treat the product with care will reduce both the life of the instrument and its reliability. If the Tester is subject to condensation, allow the Tester too completely dry before use. Always check the Tester and all the test leads for signs of damage and wear before use. Do not open the Tester under any circumstances. Keep the instrument clean and dry. Avoid testing in conditions of high electrostatic or electromagnetic fields. Maintenance should only be performed by authorized personnel. There are no user replaceable parts within the Tester. The unit should be regularly calibrated (at least annually). 12

Notes 13