Similar documents
RatioAir Burners. Model RA0750. Data /31/05. Main Specifications - RA0750

RatioAir Burners. Model RA1000. Data /31/05. Main Specifications - RA1000

Eclipse RatioAir Burners

Eclipse RatioAir Burners

Data /1/07 Eclipse RatioAir Burners Model RA0040

Eclipse Vortometric Burners Series HI

VALUPAK. Packaged gas burners

Capacities and Operating Data

Design and Application Details

VALUPAK. Packaged gas burners

North American 4485 Tempest SE

Eclipse Single-Ended Radiant Tube Burners

Design and Application Details

Product Information. Model: LNVG, LNVLG Burner Sizes: 13, 15, 17, 20, 21, 25 GENERAL DESCRIPTION U.L. STANDARD EQUIPMENT

PROFIRE V SERIES TECHNICAL DATA INFORMATION PACKET

Design and Application Details

GAS BURNERS TYPE JR Forced Draft Burners 3450 RPM motor and squirrel cage blower Leakage test, pilot and main gas cocks Gas electric pilot and gas ign

Low emissions, high performance natural gas burners

GEMINI GAS CONTROL PRODUCT INFORMATION

2.0 Burner Operating Parameters and Requirements

KINEMAX. Medium velocity gas or oil burners

MULTIFIRE. High temperature dual fuel burner

TORCH BURNERS LOW, MEDIUM, AND HI-PRESSURE SERIES DESCRIPTION LOW-PRESSURE SERIES MODEL : T,TA,TB,RTA,RTB ET,ETA,ETB,RETA,RETB 12 ET 12 RETB

TriOx Triple Air Staged Ultra Low NOx Burner

Design and Application Details

M SERIES TECHNICAL DATA INFORMATION PACKET

ECLIPSE AIR HEAT BURNERS Series AH, DAH, TAH & CAH

PT-M90 Automatic Full-Sequence Modulation Gas Control System

Burner Capacity Information, BBC 1110/2110. Burner Capacity Information, BBC 3110

LVDT/HC PILOT BURNER. External raw gas pilot burner

D SERIES TECHNICAL DATA INFORMATION PACKET

Info 110 4/98. RatioMatic Burners. RM Series version through 600 Sizes. 750 through 2000 Sizes

D SERIES TECHNICAL DATA INFORMATION PACKET

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

North American 4575 HiRAM

Specifications of OPTIMA SLS Burners

1630 SERIES CYCLOPS TM ULTRA 4 LOW NOX TM HOT AIR BAFFLE BURNER

36H Gas Control Product Information

PROFIRE E SERIES TECHNICAL DATA INFORMATION PACKET

Economite RE Series. Power Gas Burners. MADE in the USA

PROFIRE TO 92.4 mmbtu/hr High turndown burner for large firetube and watertube applications.

D SERIES BURNERS 4.2 TO 42.0 MMBTU/HR

Specifications of STICKTITE and PILOTPAK Nozzles

Field proven low emissions. State-of-the-art low NOx firing - adjustable for application flexibility

Power Flame Incorporated

Assembly Numbers. For these products, please order per the following product numbers: (configured products are those with alphanumeric text)

PROFIRE. 4.2 TO 42.0 mmbtu/hr High-efficiency burner technology for the most stringent emissions requirements.

MAXON OVENPAK LE LOW EMISSIONS, HIGH PERFORMANCE GAS BURNERS

X4 Installation and Operation Manual - POWER FLAME INCORPORATED

S1 SERIES TECHNICAL DATA INFORMATION PACKET

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

1470 SERIES HOT AIR GAS BURNER

1466 SERIES COLD AIR GAS/OIL BURNER

IMMERSION FIRED HOT WATER BOILER

Makotherm Thermal / Catalytic Oxidizer Operation and Maintenance Manual

XID ENHANCEMENT SYSTEM IMPROVED EFFICIENCY AND PERFORMANCE

FORM NO. GTZ-542 Supersedes Form No. GTZ-503 Rev. 1

W801T (Downflow) Series Models with Input Rates from 75 to 125 kbtu [15 to 37 kw] (80% A.F.U.E. )

36C and 36D Gas Control Product Information

Packaged Gas Burner. Low CO and NOx emissions. Direct spark ignition. Factory pre-set for ease of start-up and operation

Specifications of LVDT/HC-pilot burner. Materials of construction. Duct burners - LVDT/HC-pilot burner. combustion systems for industry

TZ80MSX (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 125 kbtu [15 to 37 kw] FORM NO. GTZ-544 Supersedes Form No. GTZ-503 Rev.

LP BURNER SERIES.

Specifications of MAXON VALUPAK burners for 50 Hz operation

420-19,100 MBH GPH MODEL ACO/ACGO GAS AIR OR STEAM LIGHT OIL ATOMIZING FORCED DRAFT BURNERS

Performance Selection Data

APX Nozzle-mix line burner

INDUSTRIAL MICRODIFFUSION DUAL-FUEL BURNERS

GAS-FIRED CONDENSING MOBILE HOME FURNACE DOWN FLOW & DIRECT VENT (SEALED COMBUSTION) FURNACE SPECIFICATIONS

Specifications of STICKTITE and PILOTPAK Nozzles

Low Temperature Burners - STICKTITE and PILOTPAK Nozzles

ACL HIGH EFFICIENCY BURNER ASSEMBLY PATENTED BURNER WARNING

PARTS LIST FOR SH-100LP, SH-155LP AND SH-375LP

7. SERVICING AND COMPONENT ADJUSTMENTS

Built-in Slam-Shut Valve. Independent pneumatic control Accuracy class: ±5% Response time: 1 second. 1/2, 11/16, and 3/4-inch (13, 18, and 19 mm)

Start-up Instructions

Rheem Classic Plus Series Downflow Gas Furnace

G196 Series BASOTROL Redundant Combination Gas Valve with Manual Shutoff Valve

OIL FIRED LOWBOY FURNACE SPECIFICATIONS

1200 SERIES FTR HOT AIR BAFFLE BURNER

BLOC U A-12G BLOC U C-12G

BBG Gas Beta Burner. Designed for low pressure air operation. Rugged heavy gauge steel construction

W801S (Downflow) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

Gas Conversion Kits and Instructions

Pilot Capacities/Specifications

Type HSR Pressure Reducing Regulator for Residential, Commercial or Industrial Applications

SureFire II TM Pilot Forced Draught. Gas pilot type SP-32-xx-FD. Instruction Manual 1. INTRODUCTION 2. OPERATION PRINCIPLE AND TECHNICAL SPECIFICATION

MAXON OVENPAK LE. Low emissions, high performance gas burners. Technical Catalog

Airejet. Low NOx Coal Burner. Type: Design features: NO X removal efficiencies:

MP GS/GD. Toll Free Phone, (US & Canada): (800) Toll Free Fax, (US & Canada): (800)

LVG SERIES. Gas Limiting Orifice Valve. Features. Benefits. Combustion Excellence Since 1888 LVG-1

GF802D SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (U.S. & Canadian Models)

95G2E PRODUCT SPECIFICATIONS 95% TWO-STAGE CONSTANT TORQUE GAS FURNACES CONTROLS VENTING CONFIGURATIONS HEAT EXCHANGER DESIGN INSTALLATION FEATURES

Burner Selection Criteria

INSTALLATION INSTRUCTIONS FOR THE 45RM1, 45RM2, 45RM4, 45FS1, 45UVFS1 FIBER OPTIC FLAME SCANNERS

DEXEN INDUSTRIES Inc. GENERAL CATALOG. DEXEN INDUSTRIES Inc.

W801S (UPFLOW/ HORIZONTAL) SERIES Models with Input Rates from 50 to 150 kbtu [15 to 44 kw] (80% A.F.U.E. )

CHALLENGER Propane to Natural Gas Instructions

The Combustex Pilot Pro 900 Ignition System with Pilot Tip and Flame Sensor

Applies to: Models F, B, FE, and BE with spark pilot

Transcription:

Data 330-3 9/15/07 Eclipse ImmersoJet Burners Model 3 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr) 440,000 550,000 850,000 Minimum Input (Btu/hr) 28,000 28,000 28,000 Air Inlet Pressure ("w.c.) @Max. Input Air pressure at burner inlet (Tap "A") 7.7 11.5 26.0 Blower Motor Horse Power.33.5 As Specified Main Gas Pressure ("w.c.) into regulator Max. Min. 27.7 10 27.7 14 27.7 27 Tube Backpressure ("w.c.) 1.6 2.6 6.1 Weight-less actuator (lbs) 95 100 60 CO emissions (ppm) <100 <100 <100 Piping Flame Detection Fuel (1) N.P.T. or B.S.P. Flamerod or U.V. Scanner. Natural gas, Propane, Butane For any other mixed gas, contact Eclipse for orifice sizing. (1) Different fuels require different nozzles and orificies. All information is based on laboratory testing with a tube effective length of 22 feet. Different tube sizes and conditions may affect the data. All information is based on standard tube design. Changes in the tube will alter performance and pressures. All inputs based upon gross caloric values. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air and gas piping practices.

Performance Data 200 Typical Operational Curve & Ignition Zone (Nat. Gas, Propane & Butane) % Excess Air 100 Ignition Zone Operational Curve 0 0 25% 50% 75% Input as a percentage from low fire to high fire Low Fire 28,000 Btu/hr. (Regardless of Blower) High Fire: 440,000 Btu/hr (6" w.c. Blower) 550,000 Btu/hr (10" w.c. Blower) 850,000 Btu/hr (Remote Blower) 18 Gas Orifice P vs. Input Measured from Tap "B" to Tap "D" 14 Air Orifice P vs. Input @ 3% O2 Measured from Tap "A" to Tap "C" Pressure Drop ("wc) 16 14 12 10 8 6 4 Natural Gas Propane Gas Butane Gas Pressure Drop ("wc) 12 10 8 6 4 Natural Gas Propane Gas Butane Gas 2 2 0 0 100 200 300 400 500 600 700 800 900 Input x1000 Btu/hr. 0 0 100 200 300 400 500 600 700 800 900 Input x1000 Btu/hr. 2 Eclipse Model 3 IJ, v2, Data 330-3, 9/15/07

775 (30.5) Dimensions & Specifications Dimensions in mm (inches) B D Filter/silencer option shown in gray. A C 1" NPT or BSP (Gas Inlet) 120 (4.72) A 428 (16.85) 301 (11.84) Note: See Remote Blower drawing below for Tap locations. View A A ø200 (7.87) ø230 (9.06) Flame Rod 42 (1.65) Spark Rod 352 (13.84) To Gas Inlet C L A 6 (.236) Adapter to tank wall 101.6 (4) Max. 45 o 4X90 o 68 (2.7) ø86.5 (3.41) 4x ø12 (.47) Low Pressure Blower High Pressure Blower B A 60Hz 50 Hz C D 324 (12.74) 353 (13.88) 291 (11.44) 291 (11.44) 234 (9.20) 255 (10.02) 638 (25.08) 698 (27.45) 430 (16.91) 490 (19.27) 1" NPT or BSP (Gas Inlet) 96.89 SQ. (3.81) Tap "B" Remote Blower 2-1/2" NPT or BSP Air Inlet Tap "A" Tap "C" 289 (11.37) 92.8 (3.65) 169 (6.65) Tap "D" 120 (4.72) 428 (16.85) See above drawing for Spark and Flame Rod dimension details. 403.5 (15.78) Eclipse Model 3 IJ, v2, Data 330-3, 9/15/07 3

Data 330-4 9/15/07 Eclipse ImmersoJet Burners Model 4 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 6" w.c. Packaged (60Hz) 10" w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr) 830,000 1,000,000 1,800,000 Minimum Input (Btu/hr) 100,000 100,000 100,000 Air Inlet Pressure ("w.c.) @Max. Input Air pressure at burner inlet (Tap "A") 7.8 10.5 33 Blower Motor Horse Power.5 1.0 As Specified Main Gas Pressure ("w.c.) into regulator Max. Min. 125 10 125 13 125 34 Tube Backpressure ("w.c.) 2.0 3.8 12.2 Weight-less actuator (lbs) 115 120 75 CO emissions (ppm) <100 <100 <100 Piping Flame Detection Fuel (1) N.P.T. or B.S.P. Flamerod or U.V. Scanner. Natural gas, Propane, Butane For any other mixed gas, contact Eclipse for orifice sizing. (1) Different fuels require different nozzles and orificies. All information is based on laboratory testing with a tube effective length of 51.75 feet. Different tube sizes and conditions may affect the data. All information is based on standard tube design. Changes in the tube will alter performance and pressures. All inputs based upon gross caloric values. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air and gas piping practices.

Performance Data 200 Typical Operational Curve & Ignition Zone (Nat. Gas, Propane & Butane) % Excess Air 100 Ignition Zone Operational Curve 0 0 25% 50% 75% Low Fire 100,000 Btu/hr. (Regardless of Blower) Input as a percentage from low fire to high fire High Fire: 830,000 Btu/hr (6" w.c. Blower) 1,000,000 Btu/hr (10" w.c. Blower) 1,800,000 Btu/hr (Remote Blower) 16 Gas Orifice P vs. Input Measured from Tap "B" to Tap "D" 12 Air Orifice P vs. Input @ 3% O2 Measured from Tap "A" to Tap "C" 14 Natural Gas 10 Natural Gas 12 Propane Gas Propane Gas Pressure Drop ("wc) 10 8 6 4 Butane Gas Pressure Drop ("wc) 8 6 4 Butane Gas 2 2 0 0 200 400 600 800 1000 1200 1400 1600 1800 Input x1000 Btu/hr. 0 0 200 400 600 800 1000 1200 1400 1600 1800 Input x1000 Btu/hr. 2 Eclipse Model 4 IJ, v2, Data 330-4, 9/15/07

775 (30.5) Dimensions & Specifications Dimensions in mm (inches) B D Filter/silencer option shown in gray. C A A 1-1/2" NPT or BSP Gas Inlet 491 (19.3) 309 (12.2) Note: See Remote Blower drawing below for Tap locations. View A A Flame Rod 39 (1.5) Spark Rod 147 (5.79) 420.6 (16.54) To C L Gas Inlet A 12 (.472) Adapter to tank wall 101.6 (4) Max. 87 (3.4) Low Pressure Blower High Pressure Blower B A 60Hz 50 Hz C D 374 (14.70) 404 (15.88) 315 (12.38) 348 (13.68) 263 (10.34) 304 (11.95) 725 (28.50) 786 (30.90) 452 (17.77) 512 (20.13) Remote Blower 1-1/2" NPT or BSP Gas Inlet 110 SQ (4.33) Tap "D" 491 (19.3) Tap "B" 3" NPT or BSP Air Inlet Tap "C" 345 (13.58) 147 (5.79) See above drawing for Spark and Flame Rod dimension details. 100 (3.94) Tap "A" 509 (20.03) 198 (7.8) Eclipse Model 4 IJ, v2, Data 330-4, 9/15/07 3

Data 330-6 9/15/07 Eclipse ImmersoJet Burners Model 6 IJ Version 2 Main Specifications PARAMETER BLOWER SIZE Blower Type 10"w.c. Packaged (60Hz) 15"w.c. Packaged (60Hz) Remote Blower Maximum Input (Btu/hr) 2,000,000 2,500,000 3,600,000 Minimum Input (Btu/hr) 300,000 300,000 300,000 Air Inlet Pressure ("w.c.) @Max. Input Air pressure at burner inlet (Tap "A") 9 14.4 30 Blower Motor Horse Power 1.5 3.0 As Specified Main Gas Pressure ("w.c.) into regulator Max. Min. 125 14 125 21 125 41 Tube Backpressure ("w.c.) 2.6 4 8.3 Weight-less actuator (lbs) 275 290 185 CO emissions (ppm) <100 <100 <100 Piping Flame Detection Fuel (1) N.P.T. or B.S.P. Flamerod or U.V. Scanner. Natural gas, Propane, Butane For any other mixed gas, contact Eclipse for orifice sizing. (1) Different fuels require different nozzles and orificies. All information is based on laboratory testing with a tube effective length of 50.4 feet. Different tube sizes and conditions may affect the data. All information is based on standard tube design. Changes in the tube will alter performance and pressures. All inputs based upon gross caloric values. Eclipse reserves the right to change the construction and/or configuration of our products at any time without being obliged to adjust earlier supplies accordingly. Plumbing of air and gas will affect accuracy of orifice readings. All information is based on generally acceptable air and gas piping practices.

Performance Data % Excess Air 200 100 Typical Operational Curve & Ignition Zone (Nat. Gas, Propane & Butane) Ignition Zone Operational Curve 0 0 25% 50% 75% Input as a percentage from low fire to high fire Low Fire 300,000 Btu/hr. (Regardless of Blower) High Fire: 2,000,000 Btu/hr (Low Pressure Blower) 2,500,000 Btu/hr (High Pressure w.c. Blower) 3,600,000 Btu/hr (Remote Blower) 18 Gas Orifice P vs. Input Measured from Tap "B" to Tap "D" 9 Air Orifice P vs. Input @ 3% O2 Measured from Tap "A" to Tap "C" Pressure Drop ("wc) 16 14 12 10 8 6 4 Nat. Gas Propane Butane Pressure Drop ("wc) 8 7 6 5 4 3 2 Nat. Gas Propane Butane 2 1 0 0 500 1000 1500 2000 2500 3000 3500 4000 Input x1000 Btu/hr. 0 0 500 1000 1500 2000 2500 3000 3500 4000 Input x1000 Btu/hr. 2 Eclipse Model 6 IJ, v2, Data 330-6, 9/15/07

1016 (40) 259 (10.2) Dimensions & Specifications Dimensions in mm (inches) D Filter/silencer option shown in gray. A C A 1.5" NPT or BSP Gas Inlet 491 (19.3) Note: See Remote Blower drawing below for Tap locations. ø167.5mm (6.59") View A A 8 x 45 o 22.5 o 294 (11.57) B o/ 328mm (12.91") 8 x o/ 12mm o/ 360mm (0.47") (14.17)" Flame Rod 31 (1.2) Spark Rod 80 (3.1) Low pressure blower High pressure blower 211 (8.31) A 508mm (20.00") 533mm (20.98") 676 (26.61) B 60 HZ 50 HZ 330mm (12.99") 362mm (14.25") 560 (22.05) To C LGas Inlet 306mm (12.04") 320mm (12.60") C 958mm (37.71") 1013mm (39.88") A 12 (.472) Adapter to tank wall 101.6 (4) Max. D 545mm (21.45") 604mm (23.78") 1.5" NPT or BSP Gas Inlet Tap "C" 4" NPT or BSP Air Inlet Remote Blower Tap "A" Tap "D" 342mm (13.46") 126mm (4.96") Tap "A" Tap "B" See above drawing for Spark and Flame Rod dimension details. 211mm (8.31") 491 (19.3) 211 (8.3) 676mm (26.61") Eclipse Model 6 IJ, v2, Data 330-6, 9/15/07 3