SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

Similar documents
US Panorama. New SACE Emax 2 UL 1066 From Circuit Breaker to Power Manager

ZX-Family Gas-insulated medium voltage switchgear

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

ABB Low voltage systems MNS Platform

System pro M compact Miniature Circuit Breaker SU200M for branch circuit protection acc. to UL 489

Protection and Connection Motorized and automatic transfer switches IEC Technical guide

Low Voltage Systems MNS and MNS is PowerCenter

Fuse-links type CEF-VT Rated voltages 3/7.2 kv - 10/24 kv Rated current 0.5 A 6.3 A

SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

ZX2 Gas-insulated medium voltage switchgear

SU200M Datasheet. Branch protection acc. to CSA C22.2 No.5 / UL 489

Fuse-links type CEF-S Rated voltages: 6/12 kv 30/40.5 kv Rated currents: 6.3 A 63 A

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

MEDIUM VOLTAGE PRODUCTS. Fault Current Limiters I S. -limiter and FC-Protector The worldʼs fastest switching devices

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

Product Brochure. Generator Circuit-Breaker HVR-EBCB For hydro or pump storage power plant

System pro M compact Supplementary protector S 200 PR for ring-tongue applications acc. to UL1077

1SDC210015B0203. Tmax. T Generation.

Low Voltage Main Distribution Board

Modular Standardized Electrical and Control Solutions for Fast Track Projects

cor Long Run Experience

Manual motor starters Overview and benefits

Semi-pantograph disconnector type DSSP, up to 300 kv Maximum reliability and minimal maintenance

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

TriLine PowerModules Overview with Planing Examples

Advanced retrofitting kits solutions for Megamax Megamax Emax 2

AF / AF09Z pole Contactors AC / DC Operated - with Screw Terminals

Thermal overload relay TF140DU and TF140DU-V1000

Electronic overload relays EF205 and EF370

Technical catalogue - Edition SACE Emax 2 New low voltage air circuit-breakers

Product brochure Generator circuit-breaker HVS-63S System type GCB with innovative built-in monitoring

Catalogue March InLine II - ZLBM/ZHBM Fuse Switch Disconnector

Surge arrester POLIM-C.. HD

ABB central inverters PVS to 2091 kva

Surge arrester POLIM-H.. ND

Surge arrester POLIM-H..SD

AF / AF38Z pole Contactors AC / DC Operated - with Screw Terminals

Electronic overload relay EF65, EF96 and EF146

AF / AF30Z stack 3-pole Contactors AC / DC Operated - with Screw Terminals

Mini contactors B6, BC6 with 3 pole

DATA SHEET FOR 1 TYPE COMPARTMENTALISED / NON - COMPARTMENTALISED. ( a ) CIRCUIT BREAKER FEEDERS FULLY DRAWOUT / NON DRAWOUT

AF / AF16Z pole Contactors AC / DC Operated - with Screw Terminals

NF31E-.. / NFZ31E-.. Contactor Relays AC / DC Operated - with Screw Terminals

Outdoor live tank SF6 circuit breaker EDT with integrated current transformer up to 72.5 kv

1ZSC AAA EN, REV. 7. Transformer bushings type GSBK Technical guide

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Thermal overload relay TF65 and TF96

ZX-Family Gas-insulated medium voltage switchgear

ZS4-SF Screw Clamp Terminal Blocks For 5 x 20 fuses

ABB i-bus KNX DG/S x DALI-Gateway Basic

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

ZS4-S Screw Clamp Terminal Blocks Disconnect with blade


ZS35-PEN Screw Clamp Terminal Blocks Ground + Neutral

US CATALOG. ProLine Panelboard and breakers

ZS35 Screw Clamp Terminal Blocks Feed-through

Redundancy unit CP-C.1-A-RU Accessory for CP-C.1 range power supplies

1ZSE EN, REV. 7. Oil SF 6. bushings type GOEK Technical guide

Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Uncompromising safety and comfort Miniature Circuit Breaker SU 200 M for branch circuit protection per UL and CSA

Brochure. Modular Systems wind portfolio Power Collection and Grid Connection products

Selective main circuit breakers S 750 series Technical Data

ZS4-SF1 Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses

Contact us. ABB France Electrification Products Division Low Voltage Products and Systems 3, rue Jean Perrin F Chassieu cedex / France

DS201 - DS202C New residual current circuit-breakers with overcurrent protection (RCBOs)

ZS4-SF1-T Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with test socket

Dead Tank Circuit Breaker 145PM40-C Compact design with enhanced reliability

Data Sheet Manual Motor Starter Ex9S32 Series

ZS10-S-R2 Screw Clamp Terminal Blocks Disconnect with lever

ZS4-SF1-R Screw Clamp Terminal Blocks For 5 x 20 and 5 x 25 fuses - with blown fuse indicator

ZS10 Screw Clamp Terminal Blocks Feed-through

ZS50-PE Screw Clamp Terminal Blocks Ground

ZS6-S Screw Clamp Terminal Blocks Disconnect with blade

Thermal Overload Relays

ZS4 Screw Clamp Terminal Blocks Feed-through

ZS6-3S Screw Clamp Terminal Blocks Feed-through with 3 connections

ZS4-PE Screw Clamp Terminal Blocks Ground

Transformers. Reduced emission painting for transformers Lower volatile organic compound painting systems

Data Sheet Manual Motor Starters Ex9SN Series

PQstorI One stop solution for energy storage and power quality

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

ZS10-ST Screw Clamp Terminal Blocks Test disconnect with sliding link

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

ZS6 Screw Clamp Terminal Blocks Feed-through

Voltage limiting device HVL

MEDIUM VOLTAGE PRODUCT. TJC 4 Indoor voltage transformers

SYSclad switchboard equipped with draw out type vacuum circuit breaker closed dooroperationoperation. SYSclad 12 17,5kV A.

ZS10-PE Screw Clamp Terminal Blocks Ground

Manual motor starter magnetic only MO325

Data Sheet Manual Motor Starter Ex9S32 Series

ZK2.5-SP-4P PI-Spring Terminal Blocks Disconnect with plug - with test socket

ZS4-D-CH Screw Clamp Terminal Blocks Component holder

ZK6 PI-Spring Terminal Blocks Feed-through

Emergency stops Award winning design

DBL distribution blocks 3x1 pole

System pro M compact Miniature Circuit Breaker S 200 M UC for DC and AC applications

ZS4-PE Screw Clamp Terminal Blocks Ground

Transcription:

LOW VOLTAGE SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

2 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML Robustness and reliability up to 20 g A modern ship s operational ability is fully dependent on its onboard electrical infrastructure. Over the years, the growth in the number of electrically powered subsystems on a typical naval vessel has made this infrastructure ever more complex and extensive, and has led to a steady increase in power requirements. For over 50 years, ABB SACE has been building shockproof equipment for navies around the world. The considerable installed base of the company s products on ships of the world s main navies underlines the reliability of ABB SACE electrical equipment. Since the 1950s, the company has been manufacturing circuit breakers with special features not available on the same series of equipment destined for general use. Based on this long experience, ABB SACE is proud to offer a new family of air circuit breakers for naval applications. Common data Rated service voltage Ue [V] 690 Number of poles 3 Rated insulation voltage Ui [V] 1000 Version Withdrawable Rated impulse withstand voltage Uimp [kv] 12 Automatic circuit breaker according to IEC 60947-2 Frequency [Hz] 50-60 Switch disconnector according to IEC 60947-3

3 Automatic circuit breakers SACE Emax 2 /ML E2.2 /ML E4.2 /ML E6.2 /ML Performance levels N S H N H V H V Rated uninterrupted current Iu @ 40 C Rated ultimate short-circuit breaking capacity Icu [A] 800 800 800 3200 3200 2000 4000 4000 [A] 1250 1250 1250 4000 4000 2500 5000 5000 [A] 1600 1600 1600 3200 6300 6300 [A] 2000 2000 2000 4000 [A] 2500 2500 2500 [A] 400-415 V [ka] 66 85 100 66 100 150 100 150 440 V [ka] 66 85 100 66 100 150 100 150 500-525 V [ka] 66 66 85 66 85 100 100 130 690 V [ka] 66 66 85 66 85 100 100 100 Rated service short-circuit breaking capacity Ics [%Icu] 100 100 100 100 100 100 (1) 100 100 Rated short-time withstand current Icw Rated short-circuit making capacity (peak value) Icm (1s) [ka] 66 66 85 66 85 100 100 100 (3s) [ka] 50 50 66 50 75 (2) 75 100 100 400-415 V [ka] 145 187 220 145 220 330 220 330 440 V [ka] 145 187 220 145 220 330 220 330 500-525 V [ka] 145 145 187 145 187 220 220 286 690 V [ka] 145 145 187 145 187 220 220 264 Utilization category (according to IEC 60947-2) B B B B B B B B Breaking 1) Ics: 125 ka for 400...440 V voltage 2) E4.2H 3200 A: 66 Icw (3 s) Breaking time for I<Icw [ms] 40 40 40 40 40 40 40 40 Breaking time for I>Icw [ms] 25 25 25 25 25 25 25 25 Switch-disconnectors SACE Emax 2 /ML E2.2 /ML E4.2 /ML E6.2 /ML Performance levels N/MS H/MS N/MS H/MS V/MS H/MS X/MS Rated uninterrupted current Iu @ 40 C Rated short-time withstand current Icw Rated short-circuit making capacity (peak value) Icm [A] 800 800 3200 3200 2000 4000 4000 [A] 1250 1250 4000 4000 2500 5000 5000 [A] 1600 1600 3200 6300 6300 [A] 2000 2000 4000 [A] 2500 2500 (1 s) [ka] 66 85 66 85 100 100 120 (3 s) [ka] 50 66 50 75 (1) 75 100 100 400-415 V [ka] 145 187 145 187 330 220 264 440 V [ka] 145 187 145 187 330 220 264 500-525 V [ka] 145 187 145 187 220 220 264 690 V [ka] 145 187 145 187 220 220 264 Rated short-circuit making capacity (peak value) Icm AC-23A AC-23A AC-23A AC-23A AC-23A AC-23A AC-23A 1) E4.2H/MS 3200 A: 66 KA Icw (3 s)

4 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS SACE Emax 2/ML circuit breakers effectively and simply control naval electrical installations with the highest availability and continuity of service. These circuit breakers are based on standard versions with design enhancements that guarantee operation in critical environmental conditions. SACE Emax 2/ML is a family of low-voltage air circuit breakers withstanding impacts up to 20g and certificated RINA MIL.

5 The low-voltage electrical distribution plants inside the modern ship are driven by these following growing need: Ensure service continuity by minimizing the time needed to identify and isolate faults Guarantee space optimization Optimize energy efficiency by analyzing energy consumption Reliability and service continuity SACE Emax 2 /ML is the most advanced and complete solution for ensuring service continuity. With redundant actuators and communication modules built in, Emax 2 /ML takes electrical system reliability to new levels. ABB s solution is the only one available that uses both a communication bus and electrical connections to prevent, detect and isolate electrical faults. Its unique digital zone selectivity function correctly identifies the fault zone faster and isolate it reducing the stress in the remaining active zone. As a result, the electrical protection is more robust and costly shutdowns are more effectively prevented. Moreover SACE Emax 2 /ML features enhancements to the standard three-pole withdrawable circuit breaker that guarantee operation under stressful conditions: Shock resistance High temperatures and humidity range in a saline atmosphere; ML air circuit breakers can be used in ambient conditions where air temperature varies between -25 C and +70 C (-13 F and +158 F) Presence of vibrations that are persistent and have a high amplitude in specific frequency ranges Dimension and weight optimization SACE Emax 2 /ML is the most compact circuit breaker on the market, which makes it possible to reduce the size of circuit boxes up to 30%. SACE Emax 2 /ML circuit breakers offer maximum protection, best efficiency and ratings of up to 6,300 A. The different levels of rated nominal current and breaking capacity levels have been studied to ensure optimal sizing for all ships configurations. SACE Emax 2 /ML makes it possible to standardize the circuit-breaker support structures, considerably simplifying construction of the switchboards themselves. SACE Emax 2 /ML offers the higher performances in the least space. Moreover, it allows optimal sizing of the installation and better protection of cables, busbar ducts and supports. Less space is required in the switchgear and in the metal structures. The result is less oversizing, lower weight and, therefore, higher saving related to space optimization. Performance Next-generation ships will use more advanced microgrid technologies to overcome current power distribution challenges. Electrical distribution on a ship is an islanded microgrid, connecting multiple power generators and energy storage systems, that manages directional power flows. By using smart technologies to protect, connect and control the electrical system, ships can operate more efficiently and productively. Emax 2 /ML low-voltage circuit breaker is the industry s first smart circuit breaker. Its embedded connectivity and load management software provides a comprehensive energy management solution. The load profile optimization functions of Emax 2 reduce CO 2 emissions and fuel costs. The innovative circuit breaker safeguards a ship s mission-critical loads and generators, using advanced adaptive protection to maximize productivity under all conditions. For your installations, choose the reliability, quality and experience of ABB.

6 SACE EMAX 2/ML LOW-VOLTAGE AIR CIRCUIT BREAKERS FOR NAVAL APPLICATIONS Additional information We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG.

7

ABB SACE A division of ABB S.p.A. L.V. Breakers Via Pescaria 5, 24123 Bergamo - Italy Phone: +39 035 395.111 Fax: +39 035 395.306-433 abb.com/lowvoltage Copyright 2017 ABB. All rights reserved. Specifications subject to change without notice. 1SDC200068B0201 REV A 26.9.2017