McQuay. Vertical Water Source Heat Pump. FCV, FCG & FCW 036 & 042 Vintage B. WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1)

Similar documents
McQuay. Vertical Water Source Heat Pump. FCV, FCG, FCW Vintage B. WFAS,WFDD,WFDE,WFDL,WFDS,WFME,WFMS Design A (1)

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 030, 036, 042 Design 1. Replacement Parts List No Revision B 10/2016

McQuay. Ceiling Concealed Water Source Heat Pump. CCH, CCG, CCW 015, 019 Vintage A. Last Manufactured: 1995

McQuay. Ceiling Mounted Water Source Heat Pump. WCRH, WCRW 048, 060, 070 Design 1. Replacement Parts List No Revision C 10/2016

McQuay. Enfinity Ceiling Mounted Water Source Heat Pump. WCCH, WCCW 019, 024 Design 1. Last Manufactured: 2008

McQuay. Enfinity Horizontal Water Source Heat Pump. WCRH, WCRW 007, 009, 012 Design 1. Replacement Parts List No Revision B 02/2018

McQuay. Console Water Source Heat Pump. European Unit WWME, WWMJ, WWMK, WWML Designs A, B (1, 2) Last Manufactured: 2004

Applied Decentralized Products Water Source Heat Pump / Rev.A HWH024D, HWH030D HWW024D, HWW030D PL

McQuay. Console Water Source Heat Pump. WMH, WMG, WMK, WCH, WCG 007, 009,012 Vintage B. Last Manufactured: 1998

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 007, 009, 012 Design 4. Replacement Parts List No Revision L 02/2018

McQuay. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

Daikin McQuay. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW 042, 048, 060, 070 Design 5

AAF. Console Water Source Heat Pump. CWC, CWG, CWH, CWJ, CWK Vintage B. Last Manufactured: 1994

McQuay. Incremental. PFEC, PFES, PFHC, PFHS Suite II, 2 Motor 007, 009, 012, 015 Designs A(1), B(2) Last Manufactured: 2001

McQuay Climate Control Singer

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design C (3)

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision S 01/2018

Daikin. Enfinity Horizontal Water Source Heat Pump. WCCH, WCCW Design 2. Replacement Parts List No Revision F 04/2018

McQuay. Water Source Heat Pump. HPH, HPV Vintage A, B. Last Manufactured: Replacement Parts List No Revision B 05/2012

Daikin. SmartSource Compact Vertical Water Source Heat Pump. WGCV 048, 060, 070 Design 1. Replacement Parts List No Revision D 01/2018

McQuay. Console Water Source Heat Pump. Replacement Parts List No Revision Q 07/2016

McQuay Climate Control. Water Source Heat Pump. CC, CG Vintage E, F, G. Last Manufactured: 1986

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

McQuay. Thinline Vertical Fan Coil Floor Mounted. TSF Vintage G. Last Manufactured: 1997

McQuay. HiLine Fan Coil. HSB Vintage B. Last Manufactured: Replacement Parts List No Revision C 09/2016

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 1. Replacement Parts List No Revision I 12/2015

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 007, 009, 012 Design 1

Daikin McQuay. Enfinity Vertical Water Source Heat Pump. WVFC, WVFW Design 1. Replacement Parts List No Revision V 11/2018

Daikin Daikin McQuay. SmartSource Single Stage Vertical Water Source Heat Pump. WGSV 007, 009, 012 Design 1

Daikin McQuay. Incremental. Suite II, 2 Motor PDES Design C (3) Last Manufactured: 2008

Daikin Daikin McQuay. SmartSource Single Stage Horizontal Water Source Heat Pump. WGSH 015, 019 Design 1

McQuay. Water Source Heat Pump Replacement Chassis. VF Vintage H. Last Manufactured: 1992

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW 036 Design 2. Replacement Parts List No Revision A 12/2015

McQuay Climate Control. Horizontal Water Source Heat Pump. CC, CG, CW Vintage C, D. Last Manufactured: 1986

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision C 03/2018

Daikin McQuay. Large Capacity Fan Coil Direct Drive. HCDB, HHDB Design 1. Replacement Parts List No Revision B 03/2016

McQuay. Incremental. MEK, MHK Vintage A. PKES, PKHS, PRKC, PRKH Design A (1) Replacement Parts List No Revision G 07/2017

McQuay. Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage B. FSCD, FSHD Design A (1)

McQuay. Cabinet Unit Heater. CHB, CHF Vintage A. FCHB, FCHF Design A (1) Last Manufactured: 2010

McQuay. Seasonmaker Horizontal Fan Coil. TSC Vintage G. Last Manufactured: Replacement Parts List No Revision C 08/2016

Daikin McQuay. Large Capacity Fan Coil Belt Drive. HCBB, HHBB Design 1. Replacement Parts List No Revision E 03/2018

McQuay. Seasonmaker Large Capacity Fan Coil Direct Drive. SCD, SHD Vintage A. Last Manufactured: 1986

Daikin McQuay. Vertical Stack Water Source Heat Pump. WVHC, WVHF, WVHW Design 3 009, 012 Design 4

McQuay. Large Capacity Fan Coil Belt Drive. SCB, SHB Vintage B. FCZA, FCZC, FCZH, FHZA, FHZC, FHZH S08 - S30 Design A (1)

McQuay. Central Station Air Handlers Low Pressure. LHD, LYF, LSL, LML, LWL Vintage C. LML, LSB Vintage E. Last Manufactured: 1999

McQuay. Seasonmaker Fan Coil. TSF, TSB, TSC Vintage C. Last Manufactured: Replacement Parts List No Revision D 09/2016

McQuay Climate Control Singer. Water Source Heat Pump. VF, VG, VP Vintage C. Last Manufactured: 1982

McQuay Climate Control. Commercial Unitary Rooftop. CUR Vintage F. Last Manufactured: 1996

Daikin McQuay. Thinline Horizontal Fan Coils and Cabinet Unit Heaters. FCHC, FCHH, FCHR FHHC, FHHH, FHHR 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage D. LML, LSB, MMM, MSB Vintage E

McQuay Air-Cooled Reciprocating Chiller ALR

McQuay. Central Station Air Handler. LHD, LML, LSL, LWL, LYF, MMM, MSL, MWL Vintage C. Last Manufactured: 1984

McQuay. Air-Cooled Global Reciprocating Condensing Unit. ACR Vintage A. Last Manufactured: 2003

McQuay. Reciprocating Condensing Unit. ALP Vintage C. Last Manufactured: Replacement Parts List No Revision W 10/2017

Daikin. PreciseLine Horizontal Large Capacity Blower Coil. BCHD Design 1. Replacement Parts List No Revision A 03/2019

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

McQuay Central Station Air Handler Medium Pressure MSL

McQuay. Evaporative Condenser Cooled Chiller. EGR Vintage A. Last Manufactured: Replacement Parts List No Revision B 07/2010

McQuay Climate Control Singer. Rooftop Unit. ER, R 080 Vintage A, B, C, D. Last Manufactured: 1996

ComfortPac 42 x 16. PTAC, PTHP Sizes Design C (3) Replacement Parts List No Rev. J 2/2012

ComfortPac 42 x 16. PTAC, PTHP Sizes Vintages B and B+ (2) Replacement Parts List No Rev. P 1/2012

McQuay Singer Climate Control. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage C. Last Manufactured: 1990

Westinghouse. Rooftop Heating and Cooling. IK 300 Vintage 0, 1, 2, 3, 4, 5. Last Manufactured: 1975

Westinghouse. Rooftop Heating and Cooling. IK 180 Vintage 0, 1, 2, 3, 4. Last Manufactured: 1975

McQuay. Thinline Vertical Fan Coil. FCVC, FCVH, FCVS FHVC, FHVH, FHVS, FHWC 02, 03, 04, 06, 08, 10, 12 Design 1

McQuay Climate Control Singer. Rooftop Unit. ER, R 250 Vintage C, D. Last Manufactured: Replacement Parts List No Revision C 04/2002

FHP MANUFACTURING PARTS PRICE LIST

FHP MANUFACTURING PARTS PRICE LIST

Product Manual C: Horizontal Water Source Heat Pumps Standard and Extended Range Unit Sizes 1 /2 to 10 Tons (1758 to Watts)

Daikin McQuay. Roofpak Condensing Unit Medium Cabinet, Standalone Standard & Digital Compressor Models

McQuay Climate Control Singer. Rooftop Unit. ER, R 160 Vintage A, B, C, D. Last Manufactured: 1996

McQuay Enfinity TM. Horizontal & Vertical Water Source Heat Pump 1/2 to 5 Ton. Catalog

McQuay. Thermal Systems Absorption Chiller ME, MF Vintage A. Last Manufactured: Replacement Parts List No New 05/2001

McQuay. Seasonpak Reciprocating Chiller. WHR Vintage C. Last Manufactured: Replacement Parts List No Revision I 05/2016

McQuay. Steam/Hot Water Unit Heater. UDH Vintage C. Last Manufactured: Replacement Parts List No Revision New 07/2010

Daikin McQuay. VAV Air Terminal Unit MQ FCI6, FVI5, THI5. Replacement Parts List No Revision J 07/2017

Hoshizaki America, Inc.

McQuay. Global Air-Cooled Scroll Chiller. AGZ Vintage A Two-circuit. Last Manufactured: 2005

REPLACEMENT PARTS MANUAL

McQuay. Self-Contained Unit Ventilator UAEQ 024, 036, 044, 054. UARQ, UERQ, UGRQ 024, 030, 040, 048 Design F (6)

Centrifugal Chiller. PF/PFH Size: 063. Replacement Parts List No Revision V 05/2012

Prodigy Eclipse ECC, EH330 and EH430 C or D Service Parts

Daikin. Magnitude TM Magnetic Bearing Centrifugal Chiller. WME 0501S, 0502S, 0701S, 0702S Vintage B

McQuay. Water-Cooled Screw Chiller. PFS Vintage B. Last Manufactured: Replacement Parts List No Revision D 02/2017

EMIP60 ISO. EM Series, Inch Pounds - 60 Hz EM (iso) Spec Guides Drawings Spec Sheets Extended Range Ratings Low Temp Heating.

REPLACEMENT PARTS MANUAL

Daikin McQuay. Roofpak Condensing Unit Small Cabinet, Standalone Standard & Digital Compressor Models

REPLACEMENT PARTS MANUAL

REPLACEMENT PARTS MANUAL

McQuay Climate Control Singer. Water Source Heat Pump. LE, LG, LL, LM, WA, WE, WG, WH, WM, WR, WW Vintage B. Last Manufactured: 1990

REPLACEMENT PARTS MANUAL

Parts List. Stackable Crescent Cuber. Models KM-1601MRJ/3. hoshizakiamerica.com

Product Data. 50RHR,50RVR 50RHS,50RVS Horizontal and Vertical Aquazone Water Source Heat Pumps

WATER SOURCE HEAT PUMPS REPLACEMENT PARTS MANUAL MODELS: General Notes. Contents. Important

Parts List. Stackable Crescent cuber. Models KM-1301SAH-E KM-1301SWH-E KM-1301SRH-E. hoshizakiamerica.com

TECHNICAL GUIDE GENERAL HIGH-EFFICIENCY WATER SOURCE HEAT PUMPS AND WATER COOLED AIR CONDITIONERS

Parts List. Stackable Crescent Cuber. Models KM-1301SAH/3, SWH/3, SRH/3. hoshizakiamerica.com

McQuay. Centrifugal Chiller WPV 320A - 350A. Last Manufactured: Replacement Parts List No Revision E 12/2017

Eclipse 2000 Service Parts

McQuay. Two-Stage Centrifugal Chiller WTC 700. Replacement Parts List No Revision B 07/2017

Transcription:

Replacement Parts List 057103500 Revision P 03/2016 McQuay Vertical Water Source Heat Pump FCV, FCG & FCW 036 & 042 Vintage B WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 036 & 042 Design A (1) WFDA, WFDD, WFDE, WFDG, WFDL WFDS, WFME, WFMS 042 Design B (2) To find your Daikin Applied parts distributor, call 1-800-377-2787 or visit www.daikinapplied.com

Contents About the Model Changes... 2 Parts List Revision History... 3 Nomenclature Serial... 4 Model FCV, FCG, FCW... 5 WFDD, WFDE, WFDL, WFDS, WFME, WFMS... 6 Field Installed Accessories... 7-11 Refrigeration Circuit Diagrams... 12 Compressor and Condenser Components FCV, FCG, FCW... 13 WFDD, WFDE, WFDS, WFDL, WFME, WFMS Design A (Code 3= 1)... 14 Design B (Code 3= 2)... 15 Compressor and Condenser Components FCV, FCG, FCW... 16 WFDD, WFDE,WFDS, WFDL, WFME, WFMS Design A (Code 3= 1)... 17 Design B (Code 3= 2)... 18 Fan Deck Assembly FCV, FCG, FCW Vintage B... 19 WFDD, WFDE, WFDS, WFDL, WFME, WFMS Design A... 19 WFDD, WFDE, WFDS, WFDL, WFME, WFMS Design B... 20 Controls Electromechanical- FCV, FCG, FCW... 21 Mark IV Controller- FCV, FCG, FCW, WFME, WFMS... 22 MicroTech Controller- FCV, FCG, FCW... 23 MicroTech 2000 Controller FCV, FCG, FCW, WFDA, WFDE, WFDD, WFDG, WFDS, WFDL... 24 Critical Parts List FCV, FCG, FCW Vintage B... CPL1 WFDD, WFDE,WFDS, WFDL, WFME, WFMS Design A... CPL2 WFDD, WFDE,WFDS, WFDL, WFME, WFMS Design B... CPL3 About the Model Changes In 1999 the model numbering nomenclature for the Floor Mounted Water Source Heat Pump changed: The FCV "B" Vintage unit is now the WFDL, WFDS or WFMS Design "A" or "B" unit. The FCW "C" Vintage unit is now the WFDD, WFDE or WFME Design "A" or "B" unit. The unit's components did not change when the nomenclature did (a few engineering changes have taken place since this RPL was last issued, and the part number changes are noted). The complete model number nomenclature currently used has been added to this revision. Unless otherwise noted, all components listed in this revision apply to both the current and the original model numbered units. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 2

Parts List Revision History Revision Date Description A 9-19-96 Updated RPL layout to be consistant w/ OnLine format. B 4-28-98 Page 10 & 11 - Added Fusible Plug and Solenoid 24VAC. NOTE: The page #'s referenced above may have changed due to the Rev. C reformatting. C 5/99 Reformatted. Added MicroTech 2000 components, new serial number nomenclature, complete model nomenclature. D 8/00 Page 9- Ref. # 1 size 012 208/230V pn changed to 060703201. Page 10- Ref. # 116 reversing valve size 012 p/n changed to 066533701. E 8/03 Added WFDD, WFDE, WFDL, WFDS, WFME, WFMS nomenclature. Reformatted to current standards. Cleaned up art. Renumbered footnotes in publication order. Page 5- Code 2 Vintage changed to B. Page 6- Added new (subsequent pages renumbered). Page 7,8- FIA reformatted. Pages 9 thru 11- Added new. Page 13- Ref. # 1 Added compressor manufacturer's number and capacitor specs. Revised heading to specify unit usage. P/N for grommet and sleeve for size 036 changed to 802003084 and 021487300 respectively. Pages 14, 15- Added new. Page 16- P/N for limit switch clip changed to 802017215. Pages 17,18- Added new. Page 19- Divided diagram and component table into two separate pages. Page 20- Ref. # 330 added motor for 380V units built 1/01 and later. Ref. # 332 added housing for units built 7/00 and later. Added cutoff plate. Page 22- Added transformers for units built after 3/01. Changed p/n for 208/230/60/1 size 024 compressor contactor to 0733226401. Added sensors for units built after 2/00. Page 24- Added transformers for units built after 3/01. Changed p/n for 208/230/60/1 size 024 compressor contactor to 0733226501. Added sensors for units built after 2/00. Page 25- Ref. # 451 p/n changed to 062555801. Ref. # 457 p/n changed to 062555901. F 04/04 Pages 16,17,18 - 'Size' headings on components list corrected. G 11/05 Page 10 - Added Programmable Thermostat with remote sensor pn 106710801 to Mark IV Unit Thermostats and Subbases table. H 10/09 Page 16-18 Add to reversing valve description "until 3/05" for p/n 067290301. Add reversing valve "3/05 and later" pn 106694120. Add to reversing valve solonoid description "until 3/05" for p/n 066541901. Add reversing valve solonoid "3/05 and later" pn 106694202. Add footnote change made 3/05 and later so the same component could be used for MicroTech and Mark IV units. I 2/10 Page 13,14,15- Deleted compressor vendor information. J 2/12 Page 4- Change Serial nomenclature. Page 22- Add Mark IV board p/n 056792402. Page CPL1-CPL2 Add Critical Parts List. K 6/13 Update to CS6 format. Upadate Serial. Numerous changes done. Add model WFDA & WFDG. Page 19- Delete Ref# 412. Add Cabinet or chassis components and footnote 1. Page 23- Add Alerton p/n 106393501. Delete Panels and Cabinet section on page 25 of Revision H. CPL1-3 Add Critical Parts List. L 7/13 Pages 16-18- Add drain pan p/n 060852402 and base pan p/ns 107743301 & 107743302. M 2/14 Rebrand to Daikin. N 1/15 Page 1- Add date of final mfg. Page 19- Ref 330 Change size 042 1/3 HP to 1/2 HP. Ref 331 Change capacitor to 910120044. CPL1- Delete Mark IV- DC. p/n 056792401. Change water temp sensor p/n 107201601 to 106110801. Delete air temp sensor 107201601. O 06/15 Page 19- Change 042 motor from 1/2 HP to 1/3 HP. Add motor mount kit p/n 062200601. P 03/16 Rebrand Daikin. Numerous changes. Page 19 Add page, Fan Deck Assy, (Vin A/Des A). Page 20 Change page to Fan Deck Assy (Des B). CPL1-3 Update all CPLs & change motors for CPL3 to 1/2HP p/ns 060704601 & 060704603. Daikin Applied, 13600 Industrial Park Blvd., P.O. Box 1551, Minneapolis, MN 55440 (763) 553-5330 WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 3

Nomenclature Serial Until February, 1999 7 6 A 00000 00 Plant Identification 7 = Auburn Year Manufactured Y= 1993 Z= 1994 5= 1995 6 = 1996 7 = 1997 8 = 1998 9 = 1999 A = January B = February C = March D = April E = May F = June Engineering Revision Serial Month Manufactured G = July I = August J = September K = October L = November M = December Serial February, 1999 and later AUB U 99 05 00148 Plant Identification Abbreviation AUB = Auburn Serial (build sequence) U= Unit Week of Manufacture Year of Manufacture 99= 1999 00= 2000 01= 2001 etc. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 4

Nomenclature Model - FCV, FCG, FCW FCV 036B L G L 1 1 W Y Y MTV A A Y 1 D M Y W Q Code 01 02 03 04 05 06 07 08 09 10 11 12 14 15 16 17 18 19 20 21 Code 01: Model Type FCV= Floor Mounted Vertical Water Source Heat Pump FCW= Floor Mounted Vertical WSHP, Extended Range FCG = Floor Mounted Cooling Only Code 02: Unit Size and Vintage 036B = 36,000 BTU Cooling 042B = 42,000 BTU Cooling Code 03: Control System E= Electromechanical Control M= Mark IV Control C= Microtech Control L= MicroTech Control 2000 Code 04: Unit Voltage F= 208/230/60/3 G= 208/230/60/1 N= 265/60/1 Q= 380/50/1 T= Code 05: Unit Arrangement L= Left Hand Return Air R= Right Hand Return Air Code 06: Construction Type 1= Standard E= Extra Quiet Code 07: Coaxial Heat Exchanger 1= Copper Inner Tube/Steel Outer Tube C= Cupro-Nickel Inner Tube/Steel Outer Tube Code 08: Water Regulating Valve* W= Water Regulating Valve Y= None Code 09: Starting Control R= Random Start Relay (only used with Electromechanical control) Code 10: Overflow Protection F= Float Switch (only used with Electromechanical control) Code 11: Controls SDR= Shutdown Relay Electromechanical Control Only NSR= Night Setback Relay Electromechanical Control Only NSD= Night Setback and Demand Control Relay Electromechanical Control Only SDN= Shutdown and Night Setback Relay Electromechanical Control Only MTR= Timed Output Relay MicroTech or MircoTech 2000 only MTV= Motorized Valve MicroTech or MircoTech 2000 only MBS= Boilerless System Relay MicroTech or MircoTech 2000 only MFD= Fresh Air Damper MicroTech or MircoTech 2000 only Code 12: Auxiliary Relay A= Aux. Relay Y= None Code 13: Filter* A= Throwaway Code 14: Paint* Y= None Code 15: Finned Tube Coil* 1= Copper Tube/Aluminum Coil Code 17: Fan Housing/Wheel and Motor Assembly* D= Direct Drive 2 speed Code 18: Logo and Nameplate* M= McQuay (may also have been labeled SnyderGeneral) Code 19: Construction Code* Y= None Code 20: Agency Listing* W= ETL, CSA, MEA, ARI Y= None Code 21: Warranty A= Standard Q= Extended 4-year Compressor Warranty (5 year total) S= Extended 4-year Refrigerant Circuit Warranty (5 year total) *Codes were not listed in price book. These are standard items that will only change in the case of a special, which will be denoted with an "X" in the appropriate code. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 5

Nomenclature Model WFDA, WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS WFDD 1 036 K Z 00 Z 00 AA 12 Z Z B 1 Code 01-02 03 04 05 06 07 08 09 10 11 12 13 14 15 Codes 01 & 02: Model WFDA= Floor Mounted Vertical WSHP, DDC controls/alerton, Std Range. WFDD= Floor Mounted Vertical WSHP, MicroTech control (less board), Extd Range. WFDE= Floor Mounted Vertical WSHP, MicroTech control Extd Range. WFDG= Floor Mounted Vertical WSHP, DDC controls, Geothermal Range. WFDS= Floor Mounted Vertical WSHP, MicroTech control, Std Range. WFDL= Floor Mounted Vertical WSHP, MicroTech control (less board), Std Range. WFMS= Floor Mounted Vertical WSHP, Mark IV control, Std Range. WFME= Floor Mounted Vertical WSHP, Mark IV control, Extd Range. Code 03: Design (Vintage) 1= Design A 2= Design B (042 only) Code 04: Size (1000's BTUH) 036, 042 Code 05: Unit Voltage E = 208/230/60/1 F = 208/230/60/3 J = 265/60/1 K = N = (Mark IV units only) Code 06: Coil Options Z= None Code 08: Hand Orientation Z= Not Applicable Code 09: Controls 00= None Code 10: Discharge AA= Top Discharge Code 11: Return Air/ O.A. 11= Left Hand 12= Right Hand Code 12: Power Connection Z= None Code 13: Color Z= None Code 14: SKU A= Stock B= Standard Leadtime C= Extended Leadtime Code 15: Product Style 1= 1st Style Change Code 07: Heating Options 00= None WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 6

Field Installed Accessories FCV, FCG, FCW Units Thermostat for Mark IV Units Description Thermostat Subbase Standard Manual Changeover Thermostat & Subbase. Honeywell T834C with no LED. Mounts vertically. 073319501 N/A System "Heat-Off-Cool" switch and fan "On-Auto" switch. (incl. subbase) Standard Automatic Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319701 System "Off-Auto" switch and fan "On-Auto" switch. Standard Manual & Auto. Changeover Thermostat & Subbase. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319001 073319801 System "Off-Heat-Auto-Cool" switch and fan "On-Auto" switch. Deluxe Auto. Changeover T-stat & Subbase w/ Night Setback. Honeywell T874/Q674. LED for "Service." Mounts horizontal. Requires grounding of unit "U" terminal. 073318801 073320001 Night setback bulb set 12 o F below day heating setpoint. System "Off-Auto" switch and fan "On-Auto" switch. Standard Auto. Changeover Thermostat & Subbase- For Operating Two Units. Honeywell T874/Q674. LED for "Service." Mounts horizontal. 073319101 073319601 System "Off-Auto". Programmable Electronic Thermostat & Subbase. 067114201 N/A Honeywell Chronotherm III (1 Stage Heat, 1 Stage Cool). N/A= Not Applicable. Thermostat Accessories Description Part Universal Thermostat Guard- Honeywell TG512A. 066406601 Clear plastic with ring base, lock and keys. Programmable Thermostat Guard- Honeywell TG511A. 066406702 Clear plastic with ring base, lock and keys. Deluxe Locking Cover for T874/Q674 Thermostats.- Honeywell TG504A. Applies only to T874/Q674 stats. Replaces standard cover. Includes cover, lock & keys. 073318501 1 Clear plastic with ring base, lock and keys. Deluxe Locking Cover for T874/Q674 T-stats w/ Override Switch.- Honeywell TG504A. Applies only to T874/Q674 stats. Replaces standard cover. Includes cover, lock & keys. 056972401 1 Clear plastic with ring base, lock and keys. Adapter Plate for T874/Q674 Thermostats. 073319301 Allows for horizontal thermostat to be mounted on a vertical junction box. 7- Day Time Clock (not available for 50 cycle power). Includes spring carryover. 802005716 Override Timer- 1 Hour 802005717 Override Timer- 6 Hour 802005718 Locking Control Access Cover 055145201 1 Do not use with Deluxe ACO Thermostat with override and Subbase 073318801, 073318901, 073320001. Filters Description Part 1 Inch Thick Throwaway Filter. Replacement for standard filter. 060604808 2 Inch Thick Throwaway Filter. Fits into 2" thick filter rack. 060687109 2 Inch Thick Pleated Filter. 35% efficient. 060759809 2 Inch Cleanable Filter. 060687009 Full Perimeter Return Air Duct Collar & 2" Filter Rack. 062558501 WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 7

Field Installed Accessories FCV, FCG, FCW Units Hoses & Valves Description Specification Part Fire- Rated Rubber Supply/Return Hoses. Steel Braided 2 ft. long, 3/4" I.D. 061269003 hose with one MPT and one MPT swivel fitting. 2 per unit. 3 ft. long, 3/4" I.D. 061269004 Condensate Hose Assy. Requires trap by others. Clear plastic, 30" long 060687701 1 per unit. (Includes fitting to be soldered on unit.) Fire rated, 24" long 061300001 Fire rated, 36" long 061300002 Ball Valve. Combination shutoff and balancing valve with 3/4" FPT 802026098 memory stop. 2 per unit. Unit Accessories Description Specification Part Auxiliary Relay. 24 volt DC relay to be wired to low voltage terminal block to allow a set of 803005073 SPDT pilot duty contacts to operate miscellaneous devices when the fan or compressor operate. Contact rating is 3 amp at 24 volts. Boilerless System Kit for Mark IV Control Units. 2 Includes electronics and sensor to lock out compressor operation at 50 o F 062522201 to 60 o F EWT and provide SPNO contacts to a field supplied electric heater control system. Code 03 must be "M". Multiple Unit Control Panel. 2 Master & 1 Slave 803005159 Allows master unit to be controlled by any t-stat. Slave units "follow" with paralleled operation. Not recommended with Boilerless System. Control of 3 units 056794201 Motorized Valve. Includes prewired valve operator, conduit assembly with leads and 3/4" FPT 060977301 quick connects. Valve shuts water flow off for variable pumping. 300 psig maximum oppressure. Requires control relay below. Control Relay for Motorized Valve 859004354 Auxiliary Relay Kit for DDC Controller Interface. 3 3 Relays 062522203 4 Relays 062522202 2 Kit components listed on page Field Installed Accessories- Kit Components. 3 Kit components listed below. Auxiliary Relay Kit for DC Mark IV- Components Description Part 3 Relay Kit 4 Relay Kit Relay 802005691 3 3 Relay 802005206 N/A 1 Terminal Board 802007694 1 1 RC Filter Assembly 061048001 3 3 Resistor 060813301 1 1 Capacitor 061048101 1 1 Supressor Assembly 061073401 N/A 1 Supressor 803007214 N/A 1 Diode 803007215 N/A 1 N/A= Not Applicable. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 8

Field Installed Accessories WFDA, WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Units Relays Description Part Auxiliary Relay. 24V, Normally Open. Used with WFDL & WFDS Units. 061019403 Dry Contact Relay 5 VDC in; AC/DC out, Normally Open, SPST. Replaces the standard 24V relays in the 049265603 MicroTech panel. Used with WFDL & WFDS Units. Motorized Valve Control Relay Kit Used on WFMS units with Motorized Valve. Kit contains circuit board 859004354 p/n 803005073 and 6-pin plug p/n 061370301. Pump Restart Relay Used on Mark IV units (WFMS) in conjunction w/ LWC to restart when compressor 061419001 starts. One relay required per 200 units along a 2-wire daisy chain. Time Schedule Relay. 24 VDC relay controls the Mark IV (WFMS) "U" terminal. One required per time 049265602 clock output. Replaces 24 VAC relay. MicroTech Wall- Mounted Room Sensors Description Part Sensor w/ LED, Tenant Override 073302301 Sensor w/ LED, Tenant Override, Tenant Setpoint 073302901 Sensor w/ LED, Tenant Override, Thermostat 073302401 Sensor w/ LED, Tenant Override, Tenant Setpoint, Thermostat 073303001 Hoses Description Specification Part Hose Assy- Fire Rated Condensate 3/4" X 2' 061300001 3/4" X 3' 061299901 Hose Assy- Fire Rated Supply/Return 3/4" X 2' 061269003 3/4" X 3' 061269004 Hose Assy- Plastic Condensate 3/4" X 30" 060687701 Flow Control Hose Kit- Fire Rated Supply/Return 3.0 GPM 106582913 Includes: Supply Ball Valve, Y-Strainer, and 24" Stainless Steel Hose. 3.5 GPM 106582914 Return Flow Controller, Ball Valve, (2) P/T, 24" Stainless Steel Hose. 4.0 GPM 106582915 4.5 GPM 106582916 5.0 GPM 106582917 5.5 GPM 106582918 6.0 GPM 106582919 6.5 GPM 106582920 7.0 GPM 106582921 7.5 GPM 106582922 8.0 GPM 106582923 9.0 GPM 106582924 10.0 GPM 106582925 11.0 GPM 106582926 12.0 GPM 106582927 13.0 GPM 106582928 WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 9

Field Installed Accessories WFDA, WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Units Description Part Combination Shutoff/Balancing Valve with Memory Stop (2 per unit) 802026098 Motorized Valve Kit 4. With valve/operator, conduit assy. Shuts water flow off. 300 PSIG. 4 Requires Motorized Valve control relay (see relays on previous page). Heat Pump Loop Installation Kits and Control Panels Description Specification Part Heat Pump Loop Installation Kit Controls Main Water Loop Temp. Includes Flow Switch p/n 046499800, 055331701 Immersion Sensor 049763201, O.A. Sensor p/n 049763301. Open Lower Loop Installation Kit Controls Main Water Loop Temp. Includes Flow Switch p/n 046499800, 055331702 Immersion Sensor 049763201. Loop Water Control Panel 5 LWC16 w/modem 066005213 Provides 9 (LWC16) or 17 (LWC24) outputs for heat rejection and heat LWC16 no modem 066005211 addition stages and time clock (6 max.) schedules. LWC24 w/modem 066005214 LWC24 no modem 066005212 Remote Alarm Panel 6. Monitors LWC Panel Status. 055335401 5 See RPL 055234900 for complete LWC panel parts list. 6 Panel components listed on following page. Immersion Sensor, Thermostat Guard Description Part Immersion Sensor 049763201 Thermostat Guard. Honeywell TG12A 1009. Clear plastic guard w/ ring base, lock and key. 105571103 Mark IV Unit Control Accessories Description Specification Part Multiple Unit Control Panel. Master & 1 Slave 803005159 Allows master unit to be controlled by any t-stat. Slave units "follow" Control of 3 units 056794201 6 with paralleled operation. Not recommended with Boilerless System. 3 24 VDC Aux. Relay 803005073 Boilerless System Kit. 6 062522201 6 Components listed on page following page. Ball Valves and Motorized Valves Filters and Filter Rack Description Part Filter Rack- 2" Return Air Duct Collar, Vertical. 7 062558501 Filter- 1" Throwaway 060604808 Filter- 2" Throwaway 060687109 7 Includes Top Channel p/n 062557401; Bottom Channel p/n 062557501; LH Side Angle p/n 062557601; RH Side Angle p/n 062557701. Mark IV Unit Thermostats and Subbases Description Part Thermostat Standard MCO 105570703 Subbase- Standard MCO 073319501 Thermostat and Subbase- Deluxe ACO w/ NSB & OR 105571003 Thermostat and Wallplate- Electronic, Non-Programmable 107210201 Thermostat and Wallplate- Electronic, Programmable 107210301 Thermostat, Programmable, with remote sensor 106710801 WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 10

Field Installed Accessories Kit Components Boilerless System Kit Description Part Qty. Control Box 056388301 1 Cover- Control Box 062521101 1 P.C. Board 803005127 1 Sensor- Temperature 802007871 1 Harness Assembly 060844501 1 Inverter Relay 803005073 1 Resistor 060813301 1 300 Remote Alarm Panel (RAP) 301 303 302 304 Ref. Description Part Qty. 300 Electrical Box 065812601 1 301 Switch- Silence 065812501 1 302 LED- Red 065810801 1 303 Horn- Alarm 065810901 1 304 LED- Yellow 065810803 1 310 311 Multiple Unit Control Panel 313 Ref. Description Part Qty. 310 Cover- Control Box 106436101 1 311 Circuit Board 056794001 1 312 Stand Off- Circuit Board 802028090 6 313 Box 850007827 1 312 WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 11

Refrigeration Circuit Diagrams FCV/FCW only 721 722 112 116 71 94 146 136 95 151 92 137 1 139 147 Compressor Mounting Detail 11 10 Compressor Bracket Base 12 Mounting Stud WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 12

208/60/1 230/60/1 208/60/3 230/60/3 265/60/1 208/60/1 230/60/1 208/60/3 230/60/3 Refrigeration Circuit Compressor and Compressor Components FCV, FCG, FCW 036 042 Ref Description Part 1 Compr, 32000 BTUH 066542801 1 1 Compr, 32000 BTUH 066542802 1 1 Compr, 32000 BTUH 066542803 1 Compr, 32000 BTUH 066542805 1 Compr, 32000 BTUH Rev. 00-02 060603602 1 Compr, 32000 BTUH Rev. 03 & later 066542803 1 Compr, 38000 BTUH 066542901 1 1 Compr, 38000 BTUH 066542902 1 1 Compr, 38000 BTUH 066542903 1 Compr, 38900 BTUH Rev. 00-02 060603601 1 Compr, 38000 BTUH Rev. 03 & later 066542903 1 N/S Capacitor, 35MFD 440V 067291515 1 1 1 Capacitor, 40MFD 440V 802007858 1 1 N/S Capacitor Bracket 850010570 1 1 1 1 1 N/S Capacitor Boot 067291603 1 1 1 1 1 N/S Crankcase Heater FCW units 061452301 1 1 1 1 Crankcase Heater FCW units 061452310 1 10 Hex Nut- Compressor Mount 8 802012035 4 4 4 4 4 4 4 4 4 4 4 4 4 11 Sleeve- Compressor Mount 8 021487300 4 4 4 4 4 4 4 4 4 4 4 4 4 12 Grommet 8 802003084 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Compressor Mounting Sleeve 9 044074900 4 4 4 4 4 4 4 4 4 4 4 4 4 Compressor Mounting Sleeve 9 802003425 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Lower Compressor Spacer 9 060687901 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Top Compressor Spacer 9 060687801 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Compressor Mounting Spring 9 060688001 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S= Not shown on diagram. 8 These mounting components are used on units with standard construction (Code 06= 1). 9 These mounting components are used on units with extra quiet construction (Code 06= E). WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 13

208/60/1 230/60/1 208/60/3 230/60/3 265/60/1 208/60/1 230/60/1 208/60/3 230/60/3 Refrigeration Circuit Compressor and Compressor Components WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Design A (Code 3= 1) 036 042 Ref Description Part 1 Compr, 32000 BTUH 066542801 1 1 Compr, 32000 BTUH 066542802 1 1 Compr, 32000 BTUH 066542803 1 Compr, 32000 BTUH 066542805 1 Compr, 38000 BTUH 066542901 1 1 Compr, 38000 BTUH 066542902 1 1 Compr, 38000 BTUH 066542903 1 N/S Capacitor, 35MFD 440V 067291515 1 1 1 Capacitor, 40MFD 440V 802007858 1 1 N/S Capacitor Bracket 10 850010570 1 1 1 1 1 N/S Capacitor Boot 11 067291603 1 1 1 1 1 N/S Crankcase Heater 12 061452301 1 1 1 1 Crankcase Heater 12 061452310 1 10 Hex Nut- Compressor Mount 802012035 4 4 4 4 4 4 4 4 4 4 4 4 4 11 Sleeve- Compressor Mount 021487300 4 4 4 4 4 4 4 4 4 4 4 4 4 12 Grommet, until 06/06 802003084 4 4 4 4 4 4 4 4 4 4 4 4 4 Grommet, 06/06 & later 668057101 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S= Not shown on diagram. 10 Not used after 7/00. 11 After 2/00 no longer used on 208/230/60/1 units. 12 WFDD, WFDE, WFME units only. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 14

208/60/1 230/60/1 208/60/3 230/60/3 Refrigeration Circuit Compressor and Compressor Components WFDA, WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Design B (Code 3= 2) 042 Ref Description Part 1 Compr, 38000 BTUH 066542901 1 1 Compr, 38000 BTUH 066542902 1 1 Compr, 38000 BTUH 066542903 1 1 N/S Capacitor, 40MFD 440V 802007858 1 1 N/S Crankcase Heater 12 061452301 1 10 Hex Nut- Compressor Mount 802012035 4 4 4 4 4 4 11 Sleeve- Compressor Mount 021487300 4 4 4 4 4 4 12 Grommet 668057101 4 4 4 4 4 4 N/S= Not shown on diagram. 12 WFDD, WFDE, WFME units only. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 15

Refrigeration Circuit Condenser, Evaporator, Switches, Valves, Fusible Plug Components FCV, FCG, FCW Ref. Description Part 036 042 71 Condenser, Rev. 00-02 Copper Inner Tube 060602101 1 Condenser, Rev. 00-02 Copper Inner Tube 060602201 1 Condenser, Rev. 03 & later Copper Inner Tube 107741201 1 Condenser, Rev. 03 & later Copper Inner Tube 107741301 1 Condenser, Rev. 00-02 CU-NI Inner Tube 060602102 1 Condenser, Rev. 00-02 CU-NI Inner Tube 060602202 1 Condenser, Rev. 03 & later CU-NI Inner Tube 107741202 1 Condenser, Rev. 03 & later CU-NI Inner Tube 107741302 1 92 Evaporator Coil 056915801 1 Evaporator Coil 056911801 1 94 Strainer 060623704 1 Strainer 060676205 1 95 Capillary Tube Rev. 00-02 802001041 5 Capillary Tube Rev. 00-02 060634703 6 Capillary Tube Rev. 03 060911908 5 Capillary Tube Rev. 03 060911909 6 112 Reversing Valve 1 until 2/05 067290301 1 1 Reversing Valve 2/05 to 3/11 106694104 1 1 Reversing Valve 3/11 & later 910110420 1 1 116 Solenoid, Reversing Valve 1 Mark IV Units until 2/05 066541901 1 1 MicroTech 2000 Units until 2/05 067010001 1 1 All Units 2/05 to 3/11 106694207 1 1 All Units 3/11 & later 910110439 1 1 136 Low Temp Limit Switch FCV/FCG Units 066540601 1 1 FCW Units 066540603 1 1 N/S Clip, Low Temp. Limit Switch 802017215 1 1 137 Low Pressure Switch not used 139 Fusible Plug Assy 850008345 1 1 Fusible Plug Only 850001662 1 1 146 High Pressure Switch until 11/00 802005813 1 1 High Pressure Switch 11/00 & later 106035801 1 1 147 Accumulator FCW Units 060722401 1 1 Accumulator FCW Units 802025545 1 1 151 Shrader Valve 802026161 2 2 721 Water Regulating Valve FCV/FCG Units 802026198 1 1 FCW Units 802026162 1 1 722 Shrader Valve 802026161 1 1 N/S Motorized Valve 060977301 1 1 N/S Motorized Valve Relay 859004354 1 1 N/S Base Pan LH 107743301 1 1 N/S Base Pan RH 107743302 1 1 N/S Drain Pan Assy 060852402 1 1 N/S= Not shown on diagram. 1 The reversing valve and reversing solonoid valve were changed on 2/05, so the same component could be used on MicroTech and Mark IV units. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 16

Refrigeration Circuit Condenser, Evaporator, Switches, Valves, Fusible Plug Components FCV, FCG, FCW WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Design A (Code 3= 1) Ref. Description Part 036 042 71 Condenser, Copper Inner Tube, until 07/02 107741201 1 Condenser, Copper Inner Tube, 07/02 & later 073331501 1 Condenser, Copper Inner Tube 107741301 1 92 Evaporator Coil 056915801 1 Evaporator Coil 056911801 1 94 Strainer 060623704 1 Strainer 060676205 1 95 Capillary Tube 060911908 5 Capillary Tube 060911909 6 112 Reversing Valve 1 until 2/05 067290301 1 1 Reversing Valve 2/05 to 3/11 106694104 1 1 Reversing Valve 3/11 & later 910110420 1 1 116 Solenoid, Reversing Valve 1 Mark IV Units until 2/05 066541901 1 1 MicroTech 2000 Units until 2/05 067010001 1 1 All Units 2/05 to 3/11 106694207 1 1 All Units 3/11 & later 910110439 1 1 136 Low Temp Limit Switch Std Range Units 066540601 1 1 Low Temp Limit Switch Ext Range Units 066540603 1 1 N/S Clip, Low Temp Limit Switch 802017215 1 1 137 Low Pressure Switch not used 139 Fusible Plug Assy 850008345 1 1 Fusible Plug Only 283 F 106057401 1 1 146 High Pressure Switch until 11/00 802005813 1 1 High Pressure Switch 11/00 & later 106035801 1 1 147 Accumulator Ext Range Units 060722401 1 1 Accumulator Ext Range Units 802025545 1 1 151 Shrader Valve 802026161 2 2 722 Shrader Valve 802026161 1 1 N/S Base Pan LH 107743301 1 1 N/S Base Pan RH 107743302 1 1 N/S Drain Pan Assy 060852402 1 1 N/S= Not shown on diagram. 1 The reversing valve and reversing solonoid valve were changed on 2/05, so the same component could be used on MicroTech and Mark IV units. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 17

Refrigeration Circuit Condenser, Evaporator, Switches, Valves, Fusible Plug Components WFDA, WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Design B (Code 3= 2) Ref. Description Part 042 71 Condenser Copper Inner Tube 073331203 1 92 Evaporator Coil 056911801 1 94 Strainer 060676205 1 95 Capillary Tube 060911909 6 112 Reversing Valve 1 until 2/05 067290301 1 Reversing Valve 2/05 to 3/11 106694104 1 Reversing Valve 3/11 & later 910110420 1 116 Solenoid, Reversing Valve 1 Mark IV Units until 2/05 066541901 1 MicroTech 2000 Units until 2/05 067010001 1 All Units 2/05 to 3/11 106694207 1 All Units 3/11 & later 910110439 1 136 Low Temp Limit Switch Std Range Units 066540601 1 Low Temp Limit Switch Ext Range Units 066540603 1 N/S Clip, Low Temp Limit Switch 802017215 1 137 Low Pressure Switch not used 139 Fusible Plug Assy 850008345 1 Fusible Plug Only 106057401 1 146 High Pressure Switch until 11/00 802005813 1 High Pressure Switch 11/00 & later 106035801 1 147 Accumulator Ext Range Units 060722401 1 Accumulator Ext Range Units 802025545 1 151 Shrader Valve 802026161 2 722 Shrader Valve 802026161 1 N/S Base Pan LH 107743301 1 N/S Base Pan RH 107743302 1 N/S Drain Pan Assy 060852402 1 N/S= Not shown on diagram. * The reversing valve and reversing solonoid valve were changed on 2/05, so the same component could be used on MicroTech and Mark IV units. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 18

Fan Deck Assembly FCV, FCG, FCW- Vintage A WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFM- Design A (1) 334 Cabinet/Chassis components 335 330 332 333 Unit Size/ Quantity 036 042 Ref. Part Description Part 208-230/601 208-230/60/3 265/60/1 208-230/601 208-230/60/3 330 Motor, 1/2 HP 060704601 1 1 Motor, 1/2 HP 060704603 1 Motor, 1/2 HP 060704602 1 Motor, 1/2 HP, (until 01/01) 060704604 1 Motor, 1/2 HP, (01/01 & later) 060704603 1 Motor, 1/3 HP 060961801 1 1 Motor, 1/3 HP 060961803 1 Motor, 1/3 HP, (until 01/01) 060961804 1 Motor, 1/3 HP, (01/01 & later) 060961803 1 332 Blower Housing, (until 07/00) 060699604 1 1 1 1 1 Blower Housing, (07/00 & later) 060699607 1 1 1 1 1 Blower Housing 057478601 1 1 1 1 333 Inlet Ring 060828801 1 1 1 1 1 Inlet Ring 060829001 1 1 1 1 334 Blower Wheel 802000037 1 1 1 1 1 Blower Wheel 061406601 1 1 1 1 335 Capacitor, 7.5MFD 440V 067291505 1 1 1 1 1 Capacitor, 7.5MFD 440V 037516404 1 1 1 1 N/S Bracket, Capacitor 850010570 1 1 1 1 1 1 1 1 1 N/S Cutoff Plate (until 07/00) 057479001 1 1 1 1 1 Cutoff Plate (07/00 & later) 13 057479002 1 1 1 1 1 N/S Cabinet/Chassis components 1 1 1 1 1 1 1 1 1 1 N/S= Not shown on diagram. 1 Please contact Daikin Applied with unit model and serial number for part numbers on cabinet/chassis components. 13 The cutoff plate was used with the blower housing 060699604 (the original size 036 housing). WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 19

Fan Deck Assembly WFDA, WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS Design B (Code 3= 2) Cabinet/Chassis components 334 335 330 332 333 Unit Size 042 Ref. Part Description Part 208-230/601 208-230/60/3 330 Motor, 1/2 HP 060704601 1 1 Motor, 1/2 HP 060704603 1 1 332 Blower Housing 057478601 1 1 1 1 333 Inlet Ring 060829001 1 1 1 1 334 Blower Wheel 061406601 1 1 1 1 335 Capacitor, 7.5MFD 440V, (until 02/09) 067291505 1 1 1 1 Capacitor, 7.5MFD 440V, (02/09 to 04/12) 669241701 1 1 1 1 Capacitor, 7.5MFD 440V, (04/12 & later) 910120044 1 1 1 1 N/S Bracket, Capacitor 850010570 1 1 1 1 N/S Cabinet/Chassis components 1 1 1 1 1 N/S= Not shown on diagram. 1 Please contact Daikin Applied with unit model and serial number for part numbers on cabinet/chassis components. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 20

208/60/1 230/60/1 208/60/3 230/60/3 265/60/1 208/60/1 230/60/1 208/60/3 230/60/3 Controls Electromechanical FCV, FCG, FCW Components 036 042 Ref Description Part N/S Main Control PC Board Electromechanical (C03=E) 060679202 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Stand Off- PC Board 802028115 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Nylon Nut 802012415 4 4 4 4 4 4 4 4 4 4 4 4 4 N/S Compressor Contactor 073322301 1 1 1 1 Compressor Contactor 073322401 1 1 1 1 Compressor Contactor 073322501 1 1 Compressor Contactor 073322201 1 Compressor Contactor 073322601 1 1 N/S Fan Relay 056992205 1 1 Fan Relay 056992201 1 1 N/S Transformer until 3/01 060614101 1 1 1 1 1 1 1 1 Transformer 3/01 & later 060614102 1 1 1 1 1 1 1 1 Transformer 060676001 1 1 Transformer until 3/01 060630701 1 Transformer 3/01 & later 060614101 1 1 N/S Random Start Relay C09= R 802005496 1 1 1 1 1 1 1 1 1 Random Start Relay C09= R 802005498 1 1 1 1 N/S Shutdown Relay C11= SDR or SDN 061019403 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Night Setback Relay C11= NSR or SDN 802005728 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S N.S.B. & Demand Relay C11= NSD 802007881 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Aux. RelayCircuit Board C12= A 803005073 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Fault Relay C12= F 802005206 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Bracket for Optional Relays 063168001 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Float Switch C10= F 803005260 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Terminal Block 802007432 2 2 N/S Terminal Block Mount 061131001 1 1 N/S= Not shown on diagram. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 21

208/60/1 230/60/1 208/60/3 230/60/3 265/60/1 208/60/1 230/60/1 208/60/3 230/60/3 Controls Mark IV Controller** FCV, FCG, FCW, WFME, WFMS Components 036 042 Ref Description Part N/S Main Control PC Board Mark IV Rev. -00 14 until 4/94 060638806 1 1 1 1 1 1 1 1 1 1 1 1 1 Mark IV DC 4/94 to 3/05 056792401 1 1 1 1 1 1 1 1 1 1 1 1 1 Mark IV AC 3/05 & later 056792402 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Stand Off- PC Board 802028115 5 5 5 5 5 5 5 5 5 5 5 5 5 N/S Nylon Nut 14 802012415 5 5 5 5 5 5 5 5 5 5 5 5 5 N/S Compressor Contactor 073322301 1 1 1 1 Compressor Contactor 073322401 1 1 1 1 Compressor Contactor 073322501 1 1 Compressor Contactor 073322201 1 Compressor Contactor 073322601 1 1 N/S Fan Relay 056992205 1 1 Fan Relay 056992201 1 1 N/S Transformer until 3/01 060614101 1 1 1 1 1 1 1 1 Transformer 3/01 & later 060614102 1 1 1 1 1 1 1 1 Transformer until 3/01 060676001 1 1 Transformer 3/01 & later 060676002 1 1 Transformer until 3/01 060630701 1 Transformer 3/01 & later 060630702 1 Transformer until 1/01 060614101 1 Transformer 1/01 to 3/01 4EPC7926 1 Transformer 3/01 & later 107228901 1 N/S Aux. Relay Circuit Board 14 C12= A 803005073 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Fault Relay 14 C12= F 802005206 1 1 1 1 1 1 1 1 1 1 1 1 1 N/S Terminal Block 802007432 2 2 N/S Terminal Block Mount 061131001 1 1 N/S= Not shown on diagram. * FCV, FCG, FCW code 03= M. 14 Never applied to WFME or WFMS units. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 22

208/60/1 230/60/1 208/60/3 230/60/3 265/60/1 208/60/1 230/60/1 208/60/3 230/60/3 Controls MicroTech Controller FCV, FCG, FCW Components 036 042 Ref Description Part N/S PC Board- Main Controller MicroTech Controller 060959401 1 1 1 1 1 1 1 1 1 1 1 N/S Stand Off- PC Board 802028115 1 1 1 1 1 1 1 1 1 1 1 N/S Terminal Block- 3 Pole 049759001 2 2 2 2 2 2 2 2 2 2 2 N/S Terminal Block- 4 Pole 049759002 1 1 1 1 1 1 1 1 1 1 1 N/S Compressor Contactor 073300101 1 1 1 1 Compressor Contactor 073322501 1 1 1 1 Compressor Contactor 073322501 1 1 Compressor Contactor 073300101 1 N/S Fan Relay 047356506 1 1 1 1 Fan Relay 047356506 1 1 1 1 Fan Relay 056992205 1 1 Fan Relay 047356506 1 N/S Transformer until 3/01 060614101 1 1 1 1 1 1 1 1 Transformer 3/01 & later 060614102 1 1 1 1 1 1 1 1 Transformer 060676001 1 1 Transformer until 3/01 060630701 1 Transformer 3/01 & later 060630702 1 N/S Transformer 24V- 9V 060949301 1 1 1 1 1 1 1 1 1 1 1 N/S Timed Output Relay C11= MTR 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Boilerless System Relay C11= MBS 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Fresh Air Damper Relay C11= MFD 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Motorized Valve Relay C11= MTV 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Air Temp Sensor Assy 060988402 1 1 1 1 1 1 1 1 1 1 1 Sensor Only until 12/99 4EZS9158 1 1 1 1 1 1 1 1 1 1 1 Sensor Only 12/99 & later 106110801 1 1 1 1 1 1 1 1 1 1 1 N/S Water Temp Sensor Assy 060988406 1 1 1 1 1 1 1 1 1 1 1 Sensor Only until 12/99 4EZS9158 1 1 1 1 1 1 1 1 1 1 1 Sensor Only 12/99 & later 106110801 1 1 1 1 1 1 1 1 1 1 1 N/S= Not shown on diagram. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 23

208/60/1 230/60/1 208/60/3 230/60/3 265/60/1 208/60/1 230/60/1 208/60/3 230/60/3 Controls MicroTech 2000 Controller FCV, FCG, FCW, WFDE, WFDS Alerton Controller- WFAS Components 036 042 Ref Description Part N/S PC Board- Main Controller MicroTech Controller 15 until 5/08 073312502 1 1 1 1 1 1 1 1 1 1 1 MicroTech Controller 15 5/08 to 9/12 073312504 1 1 1 1 1 1 1 1 1 1 1 MicroTech Controller 15 9/12 & later 250808401 1 1 1 1 1 1 1 1 1 1 1 Alerton 106393501 1 1 1 1 1 1 1 1 1 1 1 N/S Stand Off- PC Board 802028115 1 1 1 1 1 1 1 1 1 1 1 N/S Terminal Board- 7 Pos. LoVolt 073315201 1 1 1 1 1 1 1 1 1 1 1 N/S Terminal Block- ELUPC 061365602 1 1 1 1 1 1 1 1 1 1 1 N/S Compressor Contactor 073300101 1 1 1 1 Compressor Contactor 073322501 1 1 1 1 Compressor Contactor 073322501 1 1 Compressor Contactor 073300101 1 N/S Fan Relay 047356506 1 1 1 1 1 1 1 1 1 Fan Relay 056992205 1 1 N/S Transformer until 3/01 060614101 1 1 1 1 1 1 1 1 Transformer 3/01 & later 060614102 1 1 1 1 1 1 1 1 Transformer until 3/01 060676001 1 1 Transformer 3/01 & later 060676002 1 1 Transformer until 3/01 060630701 1 Transformer 3/01 & later 060630702 1 N/S Timed Output Relay 16 C11= MTR 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Boilerless System Relay 16 C11= MBS 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Fresh Air Damper Relay 16 C11= MFD 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Motorized Valve Relay 16 C11= MTV 061019403 1 1 1 1 1 1 1 1 1 1 1 N/S Bracket for MTR, MBS, MFD or MTV 063168001 1 1 1 1 1 1 1 1 1 1 1 1 N/S Air Sensor Assy 058946502 1 1 1 1 1 1 1 1 1 1 1 Receptacle 4EGA9159 1 1 1 1 1 1 1 1 1 1 1 Sensor Only until 2/00 073305601 1 1 1 1 1 1 1 1 1 1 1 Sensor Only 2/00 & later 107201601 1 1 1 1 1 1 1 1 1 1 1 N/S Water Temp Sensor Assy 058946201 1 1 1 1 1 1 1 1 1 1 1 Sensor Only until 2/00 073305701 1 1 1 1 1 1 1 1 1 1 1 Sensor Only 2/00 and later 107201601 1 1 1 1 1 1 1 1 1 1 1 N/S= Not shown on diagram. * FCV, FCG, FCW code 03= L. 15 Does not apply to WFDDL or WFDL units. 16 Does not apply to WFDS, WFDL, WFDE or WFDD units. WSHP: FCV,FCG,FCW Vint. B; WFD_, WFM_ Des. A&B, Sizes 36/42 Rev. P 03/16 RPL 0571035/ Page 24

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Vertical WSHP FCV, FCG, FCW 036, 042 Vintage B Critical Components Unit Sizes Voltage Part Control Control Board, Mark IV- AC ALL ALL 056792402 Control Board, MicroTech ALL ALL 060959401 Control Board, MicroTech 2000 ALL ALL 250808401 Electromechanical ALL ALL 060679202 Compressor Compressor 036 208/230/60/1 066542801 Compressor 036 208/230/60/3 066542802 Compressor 036 066542803 Compressor 036 265/60/1 066542805 Compressor 036 066542805 Compressor 042 208/230/60/1 066542901 Compressor 042 208/230/60/3 066542902 Compressor 042 066542903 Compressor 042 066542903 Blower Motor Motor,1/2HP 036 208/230/60/1 060704601 Motor,1/2HP 036 208/230/60/3 060704601 Motor,1/2HP 036 060704603 Motor,1/2HP 036 060704603 Motor,1/2HP 036 265/60/1 060704602 Motor,1/3HP 042 208/230/60/1 060961801 Motor,1/3HP 042 208/230/60/3 060961801 Motor,1/3HP 042 060961803 Motor,1/3HP 042 060961803 Fan Housing and Wheel Fan Housing 036 N/A 060699607 Fan Housing 042 N/A 057478601 Wheel, Blower 036 N/A 802000037 Wheel, Blower 042 N/A 061406601 Sensor Air Temp Sensor ALL N/A 107201601 Water Temp Sensor ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 571035 Rev. P 03/2016 CPL Page 1 of 3

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Vertical WSHP WFDD, WFDE, WFDG, WFDL, WFDS, WFME, WFMS 036, 042 Design A (1) Critical Components Unit Sizes Voltage Part Control Control Board, Mark IV- DC ALL ALL 056792401 Control Board, Mark IV- AC ALL ALL 056792402 Control Board, MicroTech 2000 ALL ALL 250808401 Compressor Compressor 036 208/230/60/1 066542801 Compressor 036 208/230/60/3 066542802 Compressor 036 066542803 Compressor 036 265/60/1 066542805 Compressor 036 066542805 Compressor 042 208/230/60/1 066542901 Compressor 042 208/230/60/3 066542902 Compressor 042 066542903 Compressor 042 066542903 Blower Motor Motor,1/2HP 036 208/230/60/1 060704601 Motor,1/2HP 036 208/230/60/3 060704601 Motor,1/2HP 036 060704603 Motor,1/2HP 036 060704603 Motor,1/2HP 036 265/60/1 060704602 Motor,1/3HP 042 208/230/60/1 060961801 Motor,1/3HP 042 208/230/60/3 060961801 Motor,1/3HP 042 060961803 Motor,1/3HP 042 060961803 Fan Housing and Wheel Fan Housing 036 N/A 060699607 Fan Housing 042 N/A 057478601 Wheel, Blower 036 N/A 802000037 Wheel, Blower 042 N/A 061406601 Sensor Air Temp Sensor ALL N/A 107201601 Water Temp Sensor ALL N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 571035 Rev. P 03/2016 CPL Page 2 of 3

Critical Daikin Applied OEM Parts Are What Your HVAC Unit Needs! McQuay Vertical WSHP WFDA, WFDD, WFDE, WFDG, WFDL, WFME, WFMS 042 Design B (2) Critical Components Unit Sizes Voltage Part Control Control Board, Mark IV- DC ALL ALL 056792401 Control Board, Mark IV- AC ALL ALL 056792402 Control Board, MicroTech 2000 ALL ALL 250808401 Alerton ALL ALL 106393501 Compressor Compressor 042 208/230/60/1 066542901 Compressor 042 208/230/60/3 066542902 Compressor 042 066542903 Compressor 042 066542903 Blower Motor Motor,1/2HP 042 208/230/60/1 060704601 Motor,1/2HP 042 208/230/60/3 060704601 Motor,1/2HP 042 060704603 Motor,1/2HP 042 060704603 Fan Housing and Wheel Fan Housing 042 N/A 057478601 Wheel, Blower 042 N/A 061406601 Sensor Air Temp Sensor 042 N/A 107201601 Water Temp Sensor 042 N/A 107201601 Call Your Local Daikin Applied Parts Distributor For All Your Parts Needs. To Locate A Distributor, Go To www.daikinapplied.com or Call 1-800-37PARTS 571035 Rev. P 03/2016 CPL Page 3 of 3