CUSTOMER SUMMARY PAGE. 600 Stillwater Rd Service Address: 800 Stillwater Rd. Customer Name: City of Mahtomedi Account Number(s):

Similar documents
ON-SITE ASSESSMENT REPORT. <Engineering Firm> Presented to: <Customer> <Presentation Date> Funding by: <Report Date>

2151 Arapahoe Ave Boulder, CO Additional Service Address: Brendan Watt Site Contact: Brendan Watt Phone: (303) Phone: (303)

2017 Commercial & Industrial Program K-12 Schools Program Rebate Application

Energy Efficiency Program Overview

OREGON SCHEDULE 115 COMMERCIAL AND INDUSTRIAL ENERGY EFFICIENCY RETROFIT INCENTIVES 20,000 SQUARE FEET OR LESS NO NEW SERVICE Page 1

Lighting Rebate 2016 Rebate Application Nobles Cooperative Electric, P.O. Box 788, Worthington, MN Ph:

Xcel Energy s Energy Efficiency Programs. Derek Shockley Trade Relations Manager Commercial and Industrial

Prescriptive Lighting Rebate Application

Economics of Integrating Renewables DAN HARMS MANAGER OF RATE, TECHNOLOGY & ENERGY POLICY SEPTEMBER 2017

Meter Insights for Downtown Store

Business Member Information Company name Billing address. City State ZIP. Installation address (if different from above) Account number.

North Dakota Commercial and Industrial Electric Prices

Thomas Alston Director of Business and Policy Development. Presented By N. Scottsdale Rd, Suite 410 Scottsdale Arizona 85257

Prescriptive Rebate Program

UNDERSTANDING YOUR ENERGY BILL

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Grocery and Convenience Stores October 11, 2012

COMMERCIAL HVAC REBATES

Lighting Efficiency Lighting Retrofit Rebate Application

Appendix G - Danvers Electric

Lighting Retrofit Incentive Application for Business Customers

Commercial-in-Confidence Ashton Old Baths Financial Model - Detailed Cashflow

Lighting and Lighting Controls Energy Savings Opportunities Technical Training Series

Facilities Energy Report Fiscal Year 2016 Third Quarter

RIVERTON BOARD OF EDUCATION RIVERTON PUBLIC SCHOOL ENERGY ASSESSMENT. for NEW JERSEY BOARD OF PUBLIC UTILITIES CHA PROJECT NO

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

COMPARISON OF FIXED & VARIABLE RATES (25 YEARS) CHARTERED BANK ADMINISTERED INTEREST RATES - PRIME BUSINESS*

CHERRY HILL TOWNSHIP SCHOOLS CHERRY HILL HIGH SCHOOL WEST 2101 CHAPEL AVENUE WEST CHERRY HILL, NJ FACILITY ENERGY REPORT

TVA Distributor Retail Rates and Comprehensive Services Program Power Factor Case Studies. Gerald Johns, P.E. Power Utilization Engineer, TVA

work 2013 Lighting Rebate New equipment & construction Instructions for completing the NE&C LIGHTING Rebate Worksheet General Note:

Thank you for requesting information on our utility auditing services!

INDUSTRIAL EQUIPMENT INCENTIVES FOR OREGON BUSINESS CUSTOMERS

HILLSBOROUGH TOWNSHIP SCHOOL DISTRICT AMSTERDAM ELEMENTARY SCHOOL ENERGY ASSESSMENT. for NEW JERSEY BOARD OF PUBLIC UTILITIES CHA PROJECT NO.

Section A: CUSTOMER INFORMATION. Customer Name Electric Account Number Rate Application Number. Facility Address City State Zip Code

Company name Date submitted. Billing address City State ZIP

BERGEN COUNTY JUSTICE CENTER 10 MAIN ST. HACKENSACK, NJ, FACILITY ENERGY REPORT

HILLSDALE SCHOOL DISTRICT MEADOWBROOK ELEMENTARY SCHOOL ENERGY ASSESSMENT. for NEW JERSEY BOARD OF PUBLIC UTILITIES CHA PROJECT NO OCTOBER 2012

Balance from your previous bill $0.00 Meter # Basic Charge: 17 $ /day 3.23* Energy charge:¹ 2

HVAC Rebates Rebate Application

Pepco & Delmarva Power. Commercial & Industrial Energy Savings Program Small Business Program October 3, 2012

LIGHTING INCENTIVES FOR BUSINESS CUSTOMERS

HILLSDALE SCHOOL DISTRICT GEORGE G. WHITE MIDDLE SCHOOL ENERGY ASSESSMENT. for NEW JERSEY BOARD OF PUBLIC UTILITIES CHA PROJECT NO OCTOBER 2012

Contents. 04 Overview. 05 Residential Energy Efficiency Program. 07 Heating Ventilation and Air Conditioning (HVAC) Systems

Lighting Retrofit Incentive Application for Business Customers

HVAC Rebates Rebate Application

Better Buildings by Design Chuck Reiss Reiss Building and Renovation Hinesburg, Vermont

Average Retail Electricity Costs in North Carolina

ALZ Electrical Solar Consumer Guide

June 26, Ms. Rose LaFergola Purchasing Agent Township of Manalapan Manalapan, New Jersey Energy Audit for Manalapan Township

The Rebate Program can change without notice. CPS Energy reserved the right to discontinue the program at any time.

Solar*Rewards Frequently asked questions system size and customer usage

Lighting Retrofit Incentive Application for Business Customers

Electric Utility Incentive Programs. Marcus Wilcox, President Cascade Energy, Inc.

Past Due. Account Charges. Contract Charges Security Deposit Due - Jun 09, , Customer Service. Jun 19, PAST DUE $1,693.

CHOOSE TOSAVE. Take control of your electric bill by choosing the pricing plan that is right for you. Time-of-Use. Peak Demand. Demand Time-of-Use

Efficiency Works Business

40KW Solar System for Apple Sauce Co

Energy Conservation Efforts

ROXBURY BOARD OF EDUCATION ROXBURY HIGH SCHOOL ENERGY ASSESSMENT. For NEW JERSEY BOARD OF PUBLIC UTILITIES CHA PROJECT NO

Electrical Power Analysis of the Cal Poly Organic Farm for the Cal Poly SuPER Project

NJ Solar Market Update As of 6/30/15

INTECH AUGUST QHSE PERFORMANCE

2017 Colorado Phase 2 Regulatory Rate Review Frequently asked questions

Lighting Retrofit Incentive Application for Business Customers

UNITIL ENERGY SYSTEMS. INC. CALCULATION OF THE EXTERNAL DELIVERY CHARGE

Energy Saving Options for Small ISDs. Presented by Casey Stone, PE, CEM

CL&P s new time-of-use (TOU) rates

NHPUC No. 3 - Electricity Delivery Thirtieth Revised Page 4 Unitil Energy Systems, Inc. Superseding Twenty-Ninth Revised Page 4

CHOPTANK ELECTRIC COOPERATIVE, INC. P.S.C. Md. No. 3 Sixteenth Revised Page No A LIGHTING SERVICE Rate Schedule L - S AVAILABILITY

Minimum operation time is 1,000 hours annually. Equipment is listed on the DLC QPL. Minimum operation time is 1,000 hours annually

EXHIBIT A-2 Amending Chapter TMC (all additions and amendments effective April 1, 2018) Chapter ELECTRIC ENERGY REGULATIONS AND RATES 1

Prescriptive Program Rebate Application

Manager of Market Strategy and Planning September 22, 2008

Heber Light & Power Electric Service Rule No. 14 NET METERING SERVICE

Lighting Efficiency Lighting Retrofit Rebate Application

Lighting Efficiency Lighting Retrofit Rebate Application

Cooling Efficiency 2017 Cooling Equipment Rebate Application

Lighting Rebate large business retrofit Instructions for completing the Retrofit LIGHTING Rebate Worksheet

Lighting Efficiency Lighting Retrofit Rebate Application

Incentives for Energy Efficient Lighting (Effective August 8, 2015 through December 15, 2015 * )

Best Practices in Energy Efficiency

Montana Renewable Energy Association

Months Investor Presentation

Prescriptive Program Rebate Application

NJ Solar Market Update As of 2/29/16

This presentation was given as part of a workshop on November 14, Presenters were:

Small Business Lighting (Peak demand under 400 kw) LIGHTING RETROFIT REBATE APPLICATION

Southern California Edison Revised Cal. PUC Sheet No E Rosemead, California (U 338-E) Cancelling Revised Cal. PUC Sheet No.

Guide for Contractors September 2016

Residential Time-of-Day Service Rate Schedule R-TOD

INTECH JUNE QHSE PERFORMANCE

CHOOSE TOSAVE. Take control of your electric bill by choosing the pricing plan that is right for you. Time-of-Use. Peak Demand. Demand Time-of-Use

CITY OF GRAND ISLAND UTILITIES DEPARTMENT ELECTRIC RATE SCHEDULE Effective October 1, Ordinance No. 9133

Continuous Efficiency Improvement Loop

NYSERDA R&D Time-Sensitive Pricing Demonstration: Advanced Metering, TOU Pricing and Technologies for Multifamily Buildings

Lighting Technologies

MSU Mankato and Ameresco. GESP Project. August 29, Ameresco, Inc. 2017, All Rights Reserved

This presentation was given as part of a workshop on February 7, Presenters were:

OCEAN COUNTY ADMINISTRATION BUILDING FACILITY ENERGY REPORT 101 HOOPER AVENUE TOMS RIVER, NJ 08753

PART 2 GUIDELINES. To be eligible to receive a financial incentive, the following conditions must be met:

POST-VISIT ACTIVITY: STANDARD VERSION TEP BRIGHT STUDENTS: THE CONSERVATION GENERATION

Transcription:

CUSTOMER SUMMARY PAGE Customer Name: City of Mahtomedi Account Number(s): 51-5660076-3 Service Address: Additional Service Address: 600 Stillwater Rd Service Address: 800 Stillwater Rd Mahtomedi, MN Mahtomedi, MN Additional Service Address: Customer Contact: Bob Goebel Site Contact: Phone: 651-773-9730 Phone: Xcel Energy Rep: Scott Heimstead Energy Auditor: Rachel Kemper Phone: 715-737-4210 Company: Michaels Engineering Fax: Phone: (608) 785-1900 Building Type: Municipal Peak Demand (kw): 20 Electric Service Provided by: Xcel Energy Gas Service Provided by: Xcel Energy Fire Dept. Square Footage: 8,400-ft2 Date of Site Visit: November 17, 2009 City Hall Square Footage: 2,500-ft2

DISCLAIMER OF WARRANTIES AND LIMITATION OF LIABILITY The suggestions in this Energy Assessment ( Assessment ) are provided as a service to Xcel Energy customers and are based on a visual analysis of conditions observed at the time of the survey, information provided by the customer and from Xcel Energy, and costs based on the energy assessor s experience on similar projects. The performance guidelines provided in the Assessment are for informational purposes only and are not to be construed as a design document. Xcel Energy will not benefit in any way from a customer s decision to select a particular contractor or vendor to supply or install the products and measures suggested by the energy assessor. Xcel Energy and the energy assessor do not guarantee that any specific level of energy or costs savings will result from implementing any energy conservation measures described in this Assessment. Xcel Energy and the energy assessor shall not, under any circumstances, be liable to the customer in the event that potential energy savings are not achieved. Xcel Energy advises that customers check with their Xcel Energy Account Manager to determine the estimated value of their rebate (if any) and to verify that the equipment qualifies for Xcel Energy programs prior to implementation of any conservation measure. Some measures identified in this report may qualify for an Xcel Energy Custom Efficiency rebate. Custom Efficiency projects require pre-approval prior to purchase and installation. The customer is responsible for submitting project information to their Xcel Energy Account Manager to obtain pre-approval for Custom Efficiency projects and to determine the eligible custom rebate amount. XCEL ENERGY IS PROVIDING THIS INFORMATION AS A SERVICE TO YOU, OUR CUSTOMER. THE INFORMATION AND SUGGESTIONS IN THIS ASSESSMENT ARE PROVIDED ON AN AS IS BASIS ONLY, AND XCEL ENERGY MAKES NO REPRESENTATIONS OR WARRANTIES OF ANY KIND WITH RESPECT TO THIS ASSESSMENT. XCEL ENERGY DISCLAIMS ALL SUCH REPRESENTATIONS AND WARRANTIES, INCLUDING BUT NOT LIMITED TO WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. Neither Xcel Energy nor any of its directors, employees or other representatives will be liable for damages arising out of or in connection with the use of this Assessment, and you, the customer, knowingly and voluntarily release Xcel Energy from any such liability in connection with this Assessment. This is a comprehensive limitation of liability that applies to all damages of any kind, including (without limitation) compensatory, direct, indirect, or consequential damages, loss of data, income or profit, loss or of damage to property and claims of third parties.

Table of Contents 1. Energy Conservation Opportunities... 2 Table 1: Recommended Measures... 2 2. Facility and Operations Description... 3 3. Energy Profile... 3 Figure 1: Total Annual Energy Expense... 3 Table 2: City Hall Annual Electric Consumption Previous 12 months... 4 Figure 2: City Hall Electric Energy End Use Profile... 4 Table 3: Fire Department Annual Electric Consumption Previous 12 months... 5 Figure 3: Fire Department Electric Energy End Use Profile... 5 Table 4: City Hall Annual Gas Consumption Previous 12 months... 6 Figure 4: City Hall Gas Energy End Use Profile... 6 Table 5: Fire Department Annual Gas Consumption Previous 12 months... 7 Figure 5: Fire Department Gas Energy End Use Profile... 7 4. Energy Conservation Opportunities... 8 4.1. Summary of Recommendations... 8 Table 6: Energy Conservation Opportunities... 8 4.2. Conservation Opportunity Analysis... 8 Task 1 Install Programmable Thermostats With Setback / Setup Features... 8 Task 2 Replace Incandescent Bulbs... 9 Task 3 Maintain/Repair Weather-stripping... 9 Task 4 Install Occupancy Sensors... 9 Task 5 Install Garage Door Timers... 9 Task 6 Install High Efficient Boiler... 9 Task 7 Install High Efficiency Water Heaters... 10 4.3. Strategic Opportunity Analysis... 10 Task 8 Install Saver s Switches on Air Conditioning... 10 Task 9 Use Energy Star Equipment... 10 5. For More Information... 10 6. Equipment Inventory... 11 Table 7: Natural Gas Equipment Inventory... 11 Table 8: Electric Equipment Inventory... 11 Table 9: Lighting Inventory... 11 7. Glossary... 12

Executive Summary City of Mahtomedi requested that Xcel Energy perform an energy assessment to identify energysaving opportunities that show potential for improvement and investment options for the facility located at 600 Stillwater Rd in Mahtomedi, MN. This is the first step toward developing a longterm energy plan for City of Mahtomedi. Michaels Engineering visited City of Mahtomedi business site on November 17, 2009, and met with Bob Goebel. This energy assessment recommends strategic opportunities such as eligibility for direct load control (Saver s Switch) and areas for energy-related process improvement and describes key energy conservation opportunities. The City Hall lighting consists of T8 fixtures and recessed fixtures with both fluorescent and incandescent bulbs. The Fire Department lighting consists of T8 fixtures and a small amount of incandescent fixtures. Lighting controls consist of manual switching. The City Hall is heated and cooled by split-style furnace and condensing unit systems, controlled with programmable thermostats. The Fire Department is heated by a gas-fired boiler and gas-fired radiant heaters. Sections of the Fire Department are cooled with rooftop condensing units. Manual thermostats control the heating and cooling systems at the Fire Department. Domestic hot water is supplied by gas water heaters in both facilities. The building construction is masonry. The insulation and roofing could not be observed at the time of the audit. Regardless, the addition of insulation is not considered cost effective for this situation. The cost of adding insulation would be prohibitively expensive because it would require re-roofing of the building. Weather-stripping appeared to be intact on the facility doors and windows. Key strategic opportunities include direct load control (Saver s Switches) and using Energy Star rated equipment whenever replacement is necessary. The project cost and energy savings results presented in this report are based on rough quantities, load estimates, and hours of operation, etc. The energy calculations are performed based on similar applications in different facilities, rules of thumb, and engineering experience. The calculations and cost estimates are intended to be ballpark estimates for planning purposes only and should not be considered investment-grade. 1

1. Energy Conservation Opportunities Table 1: Recommended Measures Energy Conservation Opportunities Annual Cost Savings ($) Capital Cost ($) Simple Payback (Years) Xcel Energy Incentives ($)* 1 Program City Hall Thermostats to Setback $ 160 $ - 0.00 $ - Install Programmable Thermostats in Fire 2 Station $ 358 $ 400 1.12 $ - 3 Replace Incandescent Bulbs $ 106 $ 130 1.22 $ - 4 Repair/Maintain Weather Stripping $ 356 $ 500 1.40 $ - 5 Install Occupancy Sensors $ 188 $ 480 2.17 $ 72 6 Install Garage Door Timers $ 236 $ 600 2.55 $ - 7 Install Condensing Boiler** $ 436 $ 1,500 3.44 * 8 Install High Efficiency Water Heater** $ 100 $ 500 5.00 * 9 Install Saver's Switches n/a $ - 0.00 $ 130 10 Use Energy Star Equipment Varies Varies Varies $ - *Items marked with an asterisk are custom efficiency projects and may require pre-approval to qualify for an Xcel Energy rebate. Please check with your Xcel Energy representative before purchasing/implementing the measure. **Items marked with two asterisks include incremental costs, the difference between high efficiency and standard efficiency equipment. 2

2. Facility and Operations Description City Hall is approximately 2,500-ft2, which includes approximately 50% office space with the remaining space being a large meeting room and mechanical areas. The Fire Department is approximately 8,400 ft- 2. The main level of the Fire Department comprises of a large apparatus bay, a control center and day-room and mechanical space. The second level contains an office, a small kitchen, and a meeting room. The City Hall schedule is from 8:00 AM to 4:30 PM on weekdays with evening meetings and limited weekend occupancy. The Fire Department is in use 24/7. City of Mahtomedi owns the buildings and has plans to combine the two buildings into one within the next few years. City Hall is heated and cooled by four split-style furnaces and condensing units, controlled by programmable thermostats. The apparatus bay in the Fire Department is heated by two gas-fired radiant heaters and a gasfired boiler heats the remaining areas with condensing units for cooling, all controlled with manual thermostats. The domestic hot water for both facilities is provided by gas-fired water heaters. The City Hall is lit with 4-foot 3-lamp 32-Watt T8 fixtures in the office area and meeting room, along with a small amount of recessed incandescent lighting in the meeting room. The hallway is lit with recessed fluorescent fixtures. The Fire Department is lit with 4-foot 2-lamp T8 fixtures throughout the apparatus bay, office, day room and rest rooms. The meeting room is lit with 4-foot 1-lamp T8 fixtures. Manual switching is used to control lights. The Fire Department has a 5-horespower air compressor, a Breathing Air System and an oxygen fill station as well as battery charges and additional fire/safety equipment. The Fire Department also has laundry machines including an industrial size washer and an electric dryer. The utility rates used in the analysis are based upon 2009 data and represent the approximate incremental expenses. 3. Energy Profile The following figures and tables identify your electric and natural gas use. Figure 1: Total Annual Energy Expense $9,164 $8,768 Gas Electric 3

Table 2: City Hall Annual Electric Consumption Previous 12 months Month Days Total Total Cost Cost/ kwh Energy kwh $ $ Jan 32 2,939 $ 295 $ 0.10 Feb 31 2,724 $ 281 $ 0.10 Mar 29 2,337 $ 249 $ 0.11 Apr 30 2,316 $ 242 $ 0.10 May 29 2,152 $ 217 $ 0.10 Jun 32 2,347 $ 152 $ 0.06 Jul 30 2,584 $ 198 $ 0.08 Aug 29 2,502 $ 193 $ 0.08 Sep 32 2,705 $ 212 $ 0.08 Oct 29 2,249 $ 229 $ 0.10 Nov 29 2,327 $ 229 $ 0.10 Dec 33 2,866 $ 289 $ 0.10 Total 365 30,048 $ 2,786 Avg 30 2,504 $ 232 $ 0.09 Definition of terms can be found in the glossary. Figure 2: City Hall Electric Energy End Use Profile kwh End Use Office, Misc. 19% Air Conditioning 19% Lighting 62% 4

Table 3: Fire Department Annual Electric Consumption Previous 12 months Month Days Actual Demand Power Factor Billed Demand Total Energy Total Cost Cost/ kwh Load Factor kw kw kwh $ $ Jan 35 18.00 0.916 18.00 6,120 $ 518 $ 0.08 0.40 Feb 28 17.00 0.919 17.00 5,120 $ 466 $ 0.09 0.45 Mar 30 16.00 0.927 16.00 4,840 $ 454 $ 0.09 0.42 Apr 30 16.00 0.927 16.00 5,120 $ 460 $ 0.09 0.44 May 31 17.00 0.917 17.00 4,880 $ 437 $ 0.09 0.39 Jun 30 17.00 0.891 17.00 5,960 $ 531 $ 0.09 0.49 Jul 30 19.00 0.881 19.00 6,760 $ 648 $ 0.10 0.49 Aug 31 19.00 0.871 20.00 7,080 $ 692 $ 0.10 0.50 Sep 30 19.00 0.862 20.00 6,520 $ 651 $ 0.10 0.48 Oct 30 19.00 0.916 19.00 6,200 $ 541 $ 0.09 0.45 Nov 29 20.00 0.897 20.00 5,440 $ 485 $ 0.09 0.39 Dec 32 18.00 0.906 18.00 5,640 $ 497 $ 0.09 0.41 Total 366 69,680 $ 6,378 Avg 31 17.92 0.903 18.08 5,807 $ 532 $ 0.09 0.44 Definition of terms can be found in the glossary. Figure 3: Fire Department Electric Energy End Use Profile kwh End Use Air Office, Misc. Conditioning 15% 15% Compressed Air 22% Lighting 48% 5

Table 4: City Hall Annual Gas Consumption Previous 12 months Month Days Total Total Cost Cost/CCF Degree CCF/DD Energy Days (DD) Therms $ $ Jan 32 491 $ 525 $ 1.07 1,812 0.27 Feb 31 448 $ 450 $ 1.00 1,545 0.29 Mar 29 357 $ 313 $ 0.88 1,223 0.29 Apr 30 227 $ 185 $ 0.82 714 0.32 May 29 88 $ 77 $ 0.88 279 0.32 Jun 32 56 $ 53 $ 0.95 110 0.51 Jul 30 7 $ 25 $ 3.64 6 1.17 Aug 29 8 $ 26 $ 3.28 5 1.60 Sep 32 9 $ 26 $ 2.94 17 0.53 Oct 29 26 $ 43 $ 1.67 138 0.19 Nov 29 138 $ 137 $ 0.99 527 0.26 Dec 33 362 $ 375 $ 1.04 1,328 0.27 Total 365 2,217 $ 2,238 7,704 Avg 30 185 $ 186 $ 1.60 0.50 Definition of terms can be found in the glossary. Figure 4: City Hall Gas Energy End Use Profile CCF End Use Water Heating 4% Space Heating 96% 6

Table 5: Fire Department Annual Gas Consumption Previous 12 months Month Days Total Total Cost Cost/CCF Degree CCF/DD Energy Days (DD) Therms $ $ Jan 32 1,566 $ 1,649 $ 1.05 1,812 0.86 Feb 31 1,288 $ 1,259 $ 0.98 1,545 0.83 Mar 29 961 $ 826 $ 0.86 1,223 0.79 Apr 30 523 $ 419 $ 0.80 714 0.73 May 29 157 $ 142 $ 0.90 279 0.56 Jun 32 104 $ 99 $ 0.95 110 0.95 Jul 30 58 $ 74 $ 1.27 6 9.67 Aug 29 61 $ 78 $ 1.27 5 12.20 Sep 32 69 $ 81 $ 1.17 17 4.06 Oct 29 104 $ 127 $ 1.22 138 0.75 Nov 29 524 $ 484 $ 0.92 527 0.99 Dec 33 1,277 $ 1,293 $ 1.01 1,328 0.96 Total 365 6,692 $ 6,530 7,704 Avg 30 558 $ 544 $ 1.03 2.78 Definition of terms can be found in the glossary. Figure 5: Fire Department Gas Energy End Use Profile CCF End Use Water Heating 10% Space Heating 90% 7

4. Energy Conservation Opportunities The project cost and energy savings results presented in this report are based on rough quantities, load estimates, and hours of operation, etc. The energy calculations are performed based on similar applications in different facilities, rules of thumb, and engineering experience. The calculations and cost estimates are intended to be ballpark estimates for planning purposes only and should not be considered investmentgrade. 4.1. Summary of Recommendations For detailed description, please refer to the Conservation Opportunity Analysis section following this table. Table 6: Energy Conservation Opportunities Energy Conservation Opportunity Payback less than 2 years (low/no cost opportunities) Demand Savings Energy Savings Thermal Savings Annual Cost Savings Xcel Energy Incentives Simple Capital Cost Payback (kw) (kwh) (Therms) ($) ($) (Years) ($)* 1 Program City Hall Thermostats to Setback - 458 131 $ 160 $ - - 1a Install Programmable Thermostats in Fire Station - 424 338 $ 358 $ 400 1.12 2 Replace Incandescent Bulbs 0.5 814 - $ 106 $ 130 1.22 Repair/Maintain Weather 3 Stripping - 538 286 $ 356 $ 500 1.40 Payback 2 10+ years 1 Install Occupancy Sensors - 2,519 - $ 188 $ 480 2.17 $ 72 2 Install Garage Door Timers - - 244 $ 236 $ 600 2.55 3 Install Condensing Boiler** - - 452 $ 436 $ 1,500 3.44 * Install High Efficiency Water 4 Heater** - - 104 $ 100 $ 500 5.00 * Discount Rate Opportunities 1 Install Saver's Switches n/a n/a n/a n/a $ - - $ 130 2 Use Energy Star Equipment Varies Varies Varies Varies Varies Varies *Items marked with an asterisk are custom efficiency projects and may require pre-approval to qualify for an Xcel Energy rebate. Please check with your Xcel Energy representative before purchasing/implementing the measure. **Items marked with two asterisks include incremental costs, the difference between high efficiency and standard efficiency equipment. 4.2. Conservation Opportunity Analysis Task 1 Install Programmable Thermostats With Setback / Setup Features The Fire Department heating and cooling systems are currently controlled by manual thermostats. Install wall-mounted programmable thermostats in the Fire Department and set the temperature back 10ºF during low occupancy periods such as over night. Additionally, ensure the thermostats at City Hall are 8

programmed to setback 10ºF during unoccupied periods. Programmable thermostats allow the spaces to be set back to lower conditioning requirements when not in use, saving energy. Task 2 Replace Incandescent Bulbs Some of the lighting in the meeting room at City Hall and in the Women s restroom at the Fire Department consists of incandescent fixtures. Replace the incandescent bulbs with screw-in compact fluorescent lamps (CFLs). CFLs consume approximately one-quarter the energy incandescent bulbs consume. Be sure to install dimmable CFLs in fixtures with dimming capabilities. Note that there is no rebate available for screw-in compact fluorescent fixtures. Task 3 Maintain/Repair Weather-stripping Weather stripping deteriorates over time, especially around heavily used doors, which can leaves gaps of 1/8-inch or larger between doors and windows and their frames. Regularly inspect windows and doors and repair worn weather-stripping in these openings to reduce heating and cooling costs. This task will save energy, but is not eligible for an Xcel Energy rebate, since it is replacing existing deteriorated equipment. Task 4 Install Occupancy Sensors Restroom, break room, the kitchen and day room lighting is currently controlled by manual switching. Lights are sometimes left on at times when these spaces are unoccupied. Install wall-mounted infrared occupancy sensors in single restrooms and offices. Ceiling-mounted dual technology occupancy sensors may be required in the larger restrooms and the day room. This would reduce lighting energy usage. Xcel Energy offers incentives of $12 per wall-mounted sensor and $36 per ceiling mounted sensor, contact your account representative for more details. Task 5 Install Garage Door Timers The Fire Department garage doors are currently manually controlled and often stay open when the crew responds to a call. Install garage door timers to close the doors to reduce the heating costs for the apparatus bay. The estimated savings is rough due to limited information. Task 6 Install High Efficient Boiler The Fire Department is currently heated with an 80 percent efficient boiler. Replace the boiler with a condensing boiler when it is time to replace the existing boiler. Condensing boilers recover energy normally discharged through the flue. A condensing boiler uses a heat exchanger to pre-heat the incoming water by condensing the water vapor produced by the burning of the natural gas. Typical condensing boilers have an efficiency of 90% or greater, compared to about 80% for conventional 9

designed boilers. Xcel Energy does offer incentives for installing high efficient boilers, contact your account representative for more details. Task 7 Install High Efficiency Water Heaters The water heaters that supply hot water for these buildings have a rated efficiency of 80%. Install high-efficiency water heater with a rated efficiency of 94% or higher when the time comes to replace the water heater in the Fire Department, for example the A.O. Smith Cyclone is 97 percent efficient. Xcel Energy may offer incentives for this measure, check with your account representative for more details. 4.3. Strategic Opportunity Analysis Task 8 Install Saver s Switches on Air Conditioning Saver s Switches cycle air conditioning for short periods during peak usage periods determined by Xcel Energy. The use of Saver s Switches results in a credit of $5 per ton of air conditioning installed and controlled (per month for the four summer months). Install Saver s Switches on the Fire Department air conditioners as the City Hall is already taking advantage of this incentive. Task 9 Use Energy Star Equipment Whenever equipment replacement is necessary, consider installing Energy Star rated equipment. Possible items include refrigerators, water heaters, printers, copiers, and computers. 5. For More Information In addition to the energy conservation measures we recommend in this energy assessment, Xcel Energy offers cash rebates and a variety of payment and billing programs to better manage your cash flow. BillWise from Xcel Energy SM programs include payment options like: Auto Pay a simple and convenient way to have monthly energy payment automatically withdrawn from a bank account on the day it is due. EFT (Electronic Funds Transfer) allows simplification of the bill paying process and improving cash management by directly transferring money from your account to Xcel Energy. Pay By Phone allows quick and secure transfer of energy payment from a bank account directly to Xcel Energy, right over the phone, at no cost. Credit/Debit Cards Payments allows payment of energy bill online or by phone using a credit or debit card for a small fee. The Billing options include EDI (Electronic Data Interchange), which allows receipt of your energy bill electronically the day after the billing cycle is complete. More information on all these programs can be obtained by discussing eligibility requirements with your Xcel Energy representative. You also can call the Business Solution Center at 1-800-481-4700 or visit us at xcelenergy.com for more information about qualifying for cash rebates, discount rates or billing/payment options. 10

6. Equipment Inventory Table 7: Natural Gas Equipment Inventory Equipment Location Quantity BTUH Input Efficiency Therms/yr Carrier Furnace City Hall 1 60,000 93% 356 Carrier Furnace City Hall 1 80,000 93% 474 Carrier Furnace City Hall 1 100,000 93% 593 Carrier Furnace City Hall 1 120,000 93% 711 AO Smith Water Heater City Hall 1 50,000 80% 84 Slant Fin Boiler Fire Dept 1 275,000 80% 3,471 Radiant Heaters Fire Dept 2 100,000 80% 2,525 Bradford White Water Heater Fire Dept 1 76,000 80% 696 TOTAL 8,909 Table 8: Electric Equipment Inventory Equipment Location Quantity HP Tons Kwh/yr Carrier Condensing Unit City Hall 1 n/a 3 2,160 Carrier Condensing Unit City Hall 1 n/a 4 2,880 Carrier Condensing Units City Hall 2 n/a 5 7,200 Lennox Condensing Unit Fire Dept 1 n/a 5 8,000 Lennox Condensing Unit Fire Dept 1 n/a 1.5 2,400 Air Compressor Fire Dept 1 5 n/a 5,115 Oxygen Fill Station Fire Dept 1 4 n/a 4,092 Breating Air System Fire Dept 1 6 n/a 6,139 TOTAL 37,986 Table 9: Lighting Inventory Fixture Type Location Quantity Watts kwh/yr 4' 3L T8 City Hall- Offices 23 85 4,888 Recessed- Fluorescent City Hall- Hallway 15 26 975 Recessed- Incandescent City Hall- Mtg Rm 10 100 500 4' 3L T8 City Hall- Mtg Rm 16 85 1,360 4' 2L T8 Fire Dept- Bay & Day Rm 60 58 24,360 4' 2L T8 Fire Dept- Rst Rms 12 58 1,392 4' 1L T8 Fire Dept- Mtg Rm 20 34 1,360 Metal Halide Fire Dept- Exterior 6 295 6,195 TOTAL 41,030 11

7. Glossary The following definitions will help you understand the information and how it relates to your energy bills. Actual Demand is the highest average 15 minutes of demand over a billing period. Billed Demand is the actual demand plus the adjusted demand for power factor correction. CCF is 100 cubic feet of natural gas. For the purposes of measuring energy use, a therm and a CCF of natural gas are equivalent. Load Factor is a measure of efficiency. Load factor is the ratio of average load in kilowatt supplied during a designated period to the peak load occurring that period. Load Factor = kwh supplied in a period Peak kw in a period X Hours in a Period Power Factor measures how effectively your equipment uses electric current from the utility. Power factor is a measure of how effectively the current delivered to the equipment is converted into useful energy, and is shown as a percentage. If your power factor is below 90 percent Xcel Energy, like many utilities, charges extra for low power factor, because it costs the utility more to build and operate the additional equipment that carries the extra current to operate your equipment. Therm: A therm is a unit of energy equivalent to 100,000 BTU. 12