Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180. ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

Similar documents
II DISTRIBUTION & SUBSTATION TYPE C

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PHASERS. Operating and Instruction Manual. a n d A C C E S S O R I E S

COOPER POWER. SERIES ELF Current-Limiting Dropout Fuse Installation Instructions. Fusing Equipment MN132028EN. Pull ring. Housing

COOPER POWER SERIES. S.T.A.R. type LVR faulted circuit indicator installation instructions. Fault Indicators MN320005EN

COOPER POWER SERIES. K-Limiter back-up current-limiting fuse installation instructions. Fusing Equipment MN132010EN

COOPER POWER SERIES. 200 A Fused Loadbreak Elbow Connector Replacement Fuse Installation Instructions. Fusing Equipment MN132021EN

COOPER POWER SERIES. 600 A 15/25 kv class T-OP II connector assembly installation instructions. Deadbreak Apparatus Connectors MN650048EN

Effective November 2016 Supersedes February 2012 (S )

OPERATING INSTRUCTION

Live Wire Owner s Manual

User Guide. Model Insulation Tester / Megohmmeter. Introduction

COOPER POWER SERIES. Screened Separable Connectors MN650023EN. Effective October 2016 Supersedes March 2012 (IS )

4" ENVIRONMENTAL E-SERIES PUMPS OWNER'S MANUAL. DANGER warns about hazards that will cause. WARNING warns about hazards that can cause

COOPER POWER SERIES. Screened Separable Connectors MN650024EN. Effective October 2016 Supersedes March 2012 (IS )

ELB ELB

COOPER POWER. SERIES CMU Medium voltage power fuse installation instructions. Fusing Equipment MN132032EN

Model Battery Powered Milliohm Meter

NECO Pumping Systems

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

COOPER POWER SERIES. 200 A loadbreak junction 15 and 25 kv class installation instructions. Loadbreak Connectors MN650015EN

MAINFRAME HOT RUNNER TEMPERATURE CONTROL SYSTEMS. Instruction Manual

Plastic Tube Flar ing Syste m

IB PowlVac ITE-HK Remote Racking Device

HIGH VOLTAGE DIGITAL AMMETER

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Operator's Manual. Storage System. Ultrasound Probe Cabinet. Manufactured by:

DIGITAL VOLTAGE INDICATORS

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

INSTRUCTION MANUAL PET Fax: (503)

Mini Multimeter with Non-Contact Voltage Detector (NCV)

COOPER POWER SERIES. Edison Modular Fuse (EMF) Installation Instructions. Fusing Equipment MN132031EN

INSP-3 Wiring Inspection Tester

R & D SPECIALTIES ROTROL I USER'S MANUAL

PY-11 Voltage & Continuity Tester

OPERATING INSTRUCTION

GWI Rev. 1 October 2007 Supersedes Rev. 0 Dated February 2004

Installation and Operation Guide

COOPER POWER SERIES. S.T.A.R. Hot line voltage indicator installation instructions. Fault Indicators MN320011EN. Indicator boot.

User's Manual. Earth Ground Resistance Tester. Model Introduction

IMPORTANT SAFETY INSTRUCTIONS

User s Manual. Automatic Switch-Mode Battery Charger

MODEL No s: PP3, PP3K

ibusway for Data Center

COOPER POWER SERIES. Testing a motor capacitor on a voltage regulator procedure instructions. Voltage Regulators MN225064EN

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Replacement of 600-Ampere Bushing and 200-Ampere Bushing-Well Adapters

BREAK-SAFE Load Break & Pick-up Tool

Dielectric Withstand Tester

INSTRUCTION MANUAL PORTABLE APPLIANCE TESTER

with lcd display 12-42v

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

INSTALLATION MANUAL MODEL #100947, AMP MODEL #100949, AMP RELIANCE CONTROLS ARL SERIES AUTOMATIC TRANSFER SWITCH

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Easy/Tran TF STANDBY POWER FURNACE SWITCH TOOLS NEEDED FOR INSTALLATION. PARTS LIST for Easy / Tran TF FURNACE TRANSFER SWITCH

COOPER POWER SERIES. Electronic control battery testing, charging, and replacement instructions. Reclosers MN280074EN

S Fault Indicators. S.T.A.R. Type TPR Faulted Circuit Indicator Installation Instructions. Contents INSTALLATION PROCEDURES

COOPER POWER SERIES. 600 A 15, 25, and 35 kv Class Cleer Loadbreak Bushing Insert Installation Instructions. Loadbreak/Deadbreak Connectors MN650016EN

CurrentGuard. CurrentGuard. CurrentGuard. Plus. Surge Protective Devices. Installation,Operation and Maintenance Manual PN

Effective June 2016 New Issue

Installation Instructions For Motor Control Center (MCC) Units

SINGLE STICK DIGITAL VOLTMETER

UNDERGROUND CABLE TESTER

Use and Care Guide. Part # SC SV-OS-BZ SC SV-OS-W Model #

Users Manual. Phase Rotation Indicator

INSTRUCTION MANUAL DM5B Fax: (503)

S&C Vista Underground Distribution Switchgear

INSTALLATION INSTRUCTIONS

3 Phase Smart Controller

UBC Technical Guidelines Section Edition Commissioning of Electrical Systems Page 1 of 5

High-voltage primary bushings installation instructions

Model RP310 Owner's Manual & Installation Instructions

Table of Contents Title Page No.

SAFETY PRECAUTIONS AND WARNINGS...

Phase Sequence Tester

COOPER POWER SERIES. KA1169R Closing Coil Transfer-Switch Accessory Operation. Reclosers MN280069EN

COOPER POWER SERIES. QD5 Quik-Drive tap-changer reversing neutral stationary contact asssembly kit A26 installation instructions

48" Vanguard Slant Wall and Cone Belt Drive Fans Installation & Operator s Instruction Manual

PowerLogic High Density Metering System 4-Meter Enclosure Installation Guide

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Operator s Manual. Automatic Electric Jack Leveling. The leveling system shall only be operated under the following conditions:

COOPER POWER SERIES. High-voltage primary bushings installation instructions. OEM Equipment MN800008EN

Component Test Fixture

VOLTMETER/PHASER a n d A C C E S S O R I E S

ENTRANCE EQUIPMENT ER D PAGE 1 OF 5

i3000s/i2000 Flex AC Current Probe

Henny Penny Rotisserie Display Model SCD-6/8 TECHNICAL MANUAL

Battery Charger Retrofit Kit Q-DCCHG1 for DC Cabinet Retrofit Manual

Effective March 2015 Supersedes S August 2012

COOPER POWER SERIES. UltraSIL polymer-insulated D-73P disconnect switches installation instructions. Switches MN008004EN

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

COOPER POWER SERIES. HX-CB loadbreak fuse cutout installation instructions. Fusing Equipment MN132011EN

3-PHASE SMART CONTROLLER STP-SCIIIC INSTALLATION GUIDE

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Digitrip Retrofit System for ITE K-3000, K-3000 S, K-4000 and K-4000 S Breakers

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

T R A N S F O R M I N G T E C H N O L O G I E S, L L C O U T S T A N D I N G A L T E R N A T I V E S I N S T A T I C C O N T R O L

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

Transcription:

Manufacturing & Service: Bierer & Associates Inc. Patent No. 6,885,180 ST Series Service Tester Phase Identifier Operating Instructions ST500PGN

REV. ED. 101229 CONTENTS Limitation of Warranty and Liability Safety Message Definitions 2 Product Safety Information 3 Design and Function 4 Meter Set-Up and Testing Testing on Known Voltage 5 Testing URD / Overhead Service Conductors 6 Testing Overhead Service Connectors 7 Identify Pedestal / Transformer Conductors from Meter Base 8 Identify Pedestal / Transformer Conductors from Standard Electrical Outlet 9 Testing De-Energized URD Primary Cable for Dead 10 Testing IN/OUT Feed on Energized URD Primary Cable 11 Parts & Accessories 11 Sales & Service / Return Goods Authorization 11 1

Limitation of Warranty and Liability Bierer & Associates Inc. warrants this product to be free from defects in workmanship and material, under normal use and service conditions for a period of one year from date of shipment. Due to continuous product improvement and development, Bierer & Associates Inc. reserves the right to modify product designs and specifications without notice. It is impossible to eliminate all risks associated with the use of high voltage electrical devices including this device. Risks of serious injury or death are inherent in working around energized electrical systems. Such risks include but are not limited to variations of electrical systems and equipment, manner of use or applications, weather and environmental conditions, operator mentality, and other unknown factors that are beyond the control of Bierer & Associates Inc. Bierer & Associates Inc. do not express or imply to be an insurer of these risks, and by purchasing or using this product you AGREE TO ACCEPT THESE RISKS. IN NO EVENT SHALL Bierer & Associates Inc. BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM THE USE OR HANDLING OF THIS PRODUCT. SAFETY MESSAGE DEFINITIONS per ANSI Z535 These instructions contain important safety messages to alert the user to potentially hazardous situations, how to avoid the hazard, and the consequences of failure to follow the instruction. The safety alert symbol identifies a safety message. The signal word following the symbol indicates: DANGER A hazardous situation which, if not avoided, will result in death or serious injury and equipment damage. WARNING A hazardous situation which, if not avoided, could result in death or serious injury and equipment damage. CAUTION A hazardous situation which, if not avoided, could result in minor or moderate injury and equipment damage. NOTICE damage only. Important safety message relating to equipment 2

PRODUCT SAFETY INFORMATION WARNING 1. ST500, STRCV Meter, cable assembly, and tool adapters shall be considered insulated for 600V or less. Do not let copper end fittings come in contact with energized and/or grounded conductors at the same time. The tool adapters, fittings, and handles shall not be used on any other devices. 2. Use appropriate length live line tools for voltage being worked and maintain minimum approach distances as outlined in OSHA 1910.269, Table R-6. 3. Do not attach any part of this equipment to voltage exceeding 600 Volts Phase to Phase. The equipment shall be considered insulated for 600V or less and operational from 10V to 600V maximum. 4. This equipment should be used only by qualified employees, trained in and familiar with the safety-related work practices, safety rules and other safety requirements associated with the use of this type of equipment. 5. These instructions are not intended as a substitute for adequate training, nor do they cover all details or situations which could be encountered when operating this type of equipment. 6. Before operating this equipment, read, understand and follow all instructions contained in this manual. Keep instructions with equipment. ANCE BEFORE USE WARNING 1. Prior to using any low/high voltage test equipment a careful inspection should be made to ensure the unit is free from any contaminants such as dirt, grease, etc. and that there are no apparent physical damages. 2. ST500 tester and STRCV meter probe assemblies shall be wiped clean periodically with a silicone impregnated cloth and kept clean and free of contaminants. This will prevent tracking on the outside of the assembly and meter error. 3. Always confirm internal battery voltage before and after use. 4. Unit shall be tested on known voltage prior to each use. If a fuse is blown the unit will not measure voltage and display will remain 000 even if the conductor is energized. 3

DESIGN and FUNCTION The ST500PGN Digital All Purpose Service Tester & Phase Identifier is designed to replace numerous meters that incorporate single range or function. Each tester has three buttons for ease of use on system voltages ranging from 10 volts to 500 volts (phase-to-phase). The digital meter is capable of reading AC voltages as well as AC Current from 10 to 500 Volts/Amps. The ST500PGN kit consist of an ST500 large backlit LCD digital meter contained in plastic injection molded housing, a STRCV receiver probe for indicating signal strength and direction, cable assemblies, and a digital laser pyrometer for identifying poor service connectors. Improved voltage range and output signal creates an all purposed device that identifies the good and bad conductors without being fooled by parallel neutral paths. Patented methodology results in the most accurate and versatile secondary service tester available in the electric utility industry. ST500 Push Button Controls (Left to Right) V / I displays voltage or current OFF / SPAN Helps troubleshoot suspect connectors OFF / ON Turns unit on STRCV Switch Positions OFF position - Unit Off for storage and transit. High - 300+ Amp position Medium- 50 300 Amps position Low- Less than 50 Amp position T" position tests internal battery voltage by sounding buzzer and light indications. BATTERY REPLACEMENT STRCV - The threaded live line tool fitting on the face of the meter probe is furnished with two flat edges for use with a wrench or slip joint pliers to remove and install the fitting from the meter housing. To remove, turn the live line tool fitting in a counterclockwise direction and install in a clockwise direction. Standard 9V battery is used. ST500 A 9V battery compartment is located on the back of the unit where the magnet is mounted. A Phillips head screwdriver is needed. A spare battery is furnished with every new unit in the same compartment. 4

ST500 TESTER & STRCV METER SET-UP and TESTING WARNING see Product Safety Information, page 3. see Inspection & Maintenance, page 3. 1. Turn STRCV meter on and test basic meter functions by turning the function selector switch to the T" position. If the battery voltage is good the unit will sound a buzzer and indicate all three lights in a sequence. If the battery voltage is not good, two yellow lights and the horn will continuously beep. Always test meter before and after each use. 2. Push the OFF/ON button down to turn on the ST500. If battery voltage is good the unit will display all zeros on a backlit LCD panel. If battery is low the unit will blink an alarm symbol but will work. If battery is too low the alarm will be solid and unit will not work at all. 3. Turn both the STRCV and ST500 unit off. Neither unit features automatic off. TESTING ON KNOWN VOLTAGE 3a. Testing the ST500 on known voltage: Attach standard wall socket plug cable to unit. Insert the plug into a 120V wall outlet rated at 30A. Press down OFF/ON button to turn the unit on. Notice the voltage reading +/- 2 counts Press down V/I button to switch to current readings, notice the blue light flashing and the numbers steadily increasing on the display. 3b. Testing the STRCV while the ST500 is operating. Turn the unit to the low current position (most sensitive). Find the voltage/neutral wire using the probe end The unit should sound the buzzer and indicate the pulse direction when you ve found the wire(s) attached to the ST500. NOTICE A current limiter device (PN: CL120) can be used to minimize the breaker requirement for testing the ST500 in a standard wall socket. If the current limiter is not used it could result in tripping the breaker the unit is attached to unless it is rated for 30A or greater. 5

Testing URD / Overhead Service Conductors 1. Pull Meter or open cabinet. 2. Make sure ST500 is in the OFF position (button is up). 3. Attach alligator clips to either hot leg and neutral. 4. Turn unit on by pressing down the OFF/ON button on the right. 5. The unit will begin to blink a blue light indicating it is performing the service conductor test 6. The LCD screen will display the voltage or applied current depending on the button position. 7. After 1 minute, the ST500 will give a red or green pass/fail light in conjunction with the maximum voltage and ampacity of the circuit. 8. With only 3 possible connections, the user can quickly determine the bad conductor in the circuit. CAUTION - Before attaching the ST500 to any voltage, make sure the unit is in the OFF position. 6

Testing Overhead Service Connectors 1. Pull Meter or open cabinet. 2. Make sure ST500 is in the OFF position (button is up). 3. Attach alligator clips to either hot leg and neutral. 4. Turn unit on by pressing down the OFF/ON button on the right. 5. The unit will begin to blink a blue light indicating it is performing the service conductor test 6. The LCD screen will display the voltage or applied current depending on the button position. 7. After 1 minute, the ST500 will give a red or green pass/fail light in conjunction with the maximum voltage and ampacity of the circuit. 8. With only 3 possible connections, the user can quickly determine the bad conductor in the circuit. 9. After the test has failed a red light will come on and the ampacity displayed will be less than 500. Push the SPAN button down and wait 5 minutes before performing the next step. 10. Using the laser pyrometer (PN: STLASER) take a temperature measurement on the connectors in the circuit. A higher reading than normal indicates the bad connector in the circuit. If no abnormal reading is found visually inspect other areas. 7

Identify Pedestal / Transformer Conductors from Meter Base 1. Pull Meter or open cabinet. 2. Make sure ST500 is in the OFF position (button is up). 3. Attach alligator clips to either hot leg and neutral. 4. Turn unit on by pressing down the OFF/ON button on the right. 5. The unit will begin to blink a blue light indicating it is performing the service conductor test 6. The LCD screen will display the voltage or applied current depending on the button position. 7. After 1 minute, the ST500 will give a red or green pass/fail light in conjunction with the maximum voltage and ampacity of the circuit. 8. Turn the STRCV meter to the respective current setting that matches the displayed current reading on the ST500. 9. At the meter base, place the probe tip on each conductor such that the cable rests in the curved section of the tip. An audible tone and a directional light will come on when the tip of the probe is on the same conductor as the ST500. 10. At the pedestal/transformer, place the probe tip on each conductor such that the cable rests in the curved section of the tip. An audible tone and a directional light will come on when the tip of the probe is on the same conductor as the ST500. 8

Identify Pedestal / Transformer Conductors from Electrical Outlet 1. Locate outside electrical outlet to be used. 2. Make sure ST500 is in the OFF position (button is up). 3. Plug in current limiter device to electrical outlet so that the house breaker doesn t trip during the test. Use standard cable with ST500. 4. Turn unit on by pressing down the OFF/ON button on the right. 5. The unit will begin to blink a blue light indicating it is performing the service conductor test 6. The LCD screen will display the voltage or applied current depending on the button position. 7. After 1 minute, the ST500 will give a red or green pass/fail light in conjunction with the maximum voltage and ampacity of the circuit. 8. Turn the STRCV meter to the respective current setting that matches the displayed current reading on the ST500. 9. At the meter base, place the probe tip on each conductor such that the cable rests in the curved section of the tip. An audible tone and a directional light will come on when the tip of the probe is on the same conductor as the ST500. 10. At the pedestal/transformer, place the probe tip on each conductor such that the cable rests in the curved section of the tip. An audible tone and a directional light will come on when the tip of the probe is on the same conductor as the ST500. 9

Testing De-Energized URD Primary Cable for Dead 1. Isolate URD cable on transformer end and leave grounded on other end using bushing ground (PN: GB215 for 15kV or GB225 for 25kV) 2. Test isolated cable for dead using approved voltage detection device. 3. Make sure ST500 is in the OFF position (button is up). 3. Using alligator clip cable, attach one end to secondary voltage and the other to center conductor of isolated cable using optional probe kit (PN: PBKIT). 4. Turn unit on by pressing down the OFF/ON button on the right. 5. The unit will begin to blink a blue light indicating it is performing the service conductor test 6. The LCD screen will display the voltage or applied current depending on the button position. 7. After 1 minute, the ST500 will give a red or green pass/fail light in conjunction with the maximum voltage and ampacity of the circuit. 8. Turn the STRCV meter to the high current setting that matches the displayed current reading on the ST500. 9. At the transformer, place the probe tip on the outside jacket of the isolated cable such that the cable rests in the curved section of the tip. An audible tone and a directional light will come on, note the direction of the light. 10. At the midpoint, manhole, ditch, etc. place the probe tip on each outside jacket such that the cable rests in the curved section of the tip. An audible tone and the same directional light will come on when the tip of the probe is on the same conductor as the ST500. Other cables will have no light or the opposing directional light. 10

Testing IN/OUT Feed on Energized URD Primary Cable 1. On a loop fed circuit, open the midpoint and go to the transformer where the feed needs to be identified. 2. Make sure ST500 is in the OFF position (button is up). 3. Attach brown lead to X1 hot leg bushing and blue lead to X3 hot leg bushing. 4. Turn unit on by pressing down the OFF/ON button on the right. 5. The unit will begin to blink a blue light indicating it is working. 6. The LCD screen will display the voltage or applied current depending on the far left button position. 7. After 1 minute, the ST500 will give a green pass light in conjunction with an approximate 500A or 240V reading. 8. Turn the STRCV meter to the low current setting. 9. If the concentric neutral is good, the audible tone and directional light will be on the concentric neutral twisted off the same cable. 10. If the concentric neutral is bad, place the probe tip on each primary cable just below the elbow such that the cable rests in the curved section of the tip but not on the concentric neutral. An audible tone and a directional light will come on when the tip of the probe is on the cable being fed from the source. If the primary to secondary turns ratio exceeds 60:1, the receiver may not be sensitive enough to pick up the signal. 11

PARTS & ACCESSORIES PART NO. CL120 SCABLE ST500 STRCV 10009CHM STLASER YCABLE PA50AB GB215 / GB225 PBKIT DESCRIPTION Current limiter for electrical outlet use Standard wall outlet cable Service Tester Cable Identifier meter probe 10 handle for use with STRCV Infrared Pyrometer for OH connector testing Alligator clip cable Nylon bag for kit Grounding Bushings for URD cable ends Probe Kit for accessing center conductor NOTES Technical & Service Bierer & Associates Inc. Manufacturing & Repair 10730 Farrow Road Blythewood SC 29016 Tel: (803) 786-4839 Fax: (803) 786-5457 Email:customer_service@bierermeters.com 12