Suspension Systems catalogue 2013 / 2014

Similar documents
CEILING. SYSTEMS CI/SfB (35) Xy. Between us, ideas become reality May TRULOK Brochure.

Armstrong Trulok Suspension System Accessories (56GA)

Available in a variety of edge details for installation on Prelude 15 and Prelude 24 suspension systems.

AXIOM CIRCLE & CURVED CANOPIES For Tegular 8 mm & MicroLook 8 mm reveal edge tiles

I ve absorbed heated debates. I ve welcomed new people. I ve shaped inspirational spaces. And now I m ready to do it

QUICK-LOCK. A complete survey of all Quick-Lock ceiling systems

Knauf AMF Complete system solutions expertise for the modular ceiling from one source with strong product brands

Cable ladder systems. Development and testing

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CD SERIES SERIES

Door Closers Contents

FlowBar High Capacity Slot Diffuser

C O L M A N. Air Distribution LINEAR SLOT DIFFUSERS CE SERIES SERIES

Folding door systems: WingLine L

Hardware Friendly Options are available for plain panels 295 and 299, providing precut finished edge details for fixture openings (1 to 16 diameter)

Door Controls. Door. Controls

Plaster In Grilles 1/1.5/B/1. AHP Plaster-in Linear Bar Grille ADMP Plaster-in Linear Diffuser ALSP Plaster-in Linear Slot Diffuser

contents MALLEABLE PIPE FITTINGS BUsHEs NiPPlEs PlUgs caps BENds BackNUTs UNioNs TEEs 171 cross PN25 p socket PN25 p socket PN25 p.

Catalogue. FlowBar. High Capacity Slot Diffuser.

SAS International +44 (0) tubeline. tubular linear ceiling

Stradaflair. Strada Trench Convectors. Strada Flat Panel Range. Strada Radiant Skirting. Strada Heated & Chilled Ceilings. Strada Electrical Products

GP Lam LVL. Grade Thickness Depth , , , , , 149, 169, 189, 249 (209and 229 by special order) 2.

Swifts SW. strength, speed and flexibility STEEL WIRE CABLE TRAY / PRODUCT GUIDE

Linear Slot Diffusers Model Slot 20 & Model Slot 25

RockLap H&V Pipe Sections

HOWORTH EXFLOW 28 PREVENTS AIRBORNE INFECTION TECHNICAL SPECIFICATION. Exflow 28 Technical Specification. Page 1 of 7

Swifts SW strength, speed and flexibility

HAWA-JUNIOR 80 XINNIX POCKET SLIDING DOOR SYSTEM

HIGH CAPACITY LINEAR SLOT DUFFUSERS

GP Lam LVL. Grade Thickness Depth , 9 1 4, 9 1 2, , , 14, 16, 18, 24 (20 and 22 by special order) 2.

LINEAR SLOT DIFFUSERS

ROOFING SOLUTIONS DESIGN GUIDE PURLINS AND GIRTS DESIGN GUIDE PURLINS AND GIRTS S&T029N

Chicago Metallic 200 Snap Grid 15/16

OWAtecta. OWA metal ceilings. OWAtecta Metal ceilings

C O L M A N. Air Distribution PERFORATED FACE DIFFUSERS P SERIES SERIES

Ceiling swirl diffusers with perforated face plate

Wall and Ceiling Grille

Chicago Metallic /16

PerfectPleat. PerfectPleat M8 ULTRA. PerfectPleat. Better Air is Our Business. 4" Extended Surface Pleated Filters. DuraFlex - AAF s Patented Media

Catalog Swirl diffuser DAL 358

KLIMA Active Chilled Beams

Centrifugal Cabinet Fans Model BCF. Belt Drive Low-Profile

Spaceloft Insulation TECHNICAL GUIDE

COMPETENCE BROCHURE Filter Media DELBAG HEPA Filter. Fresh Air Freed of Floating Materials

Blast tested to 100kg and now 500kg charges and also IED devices

TBS MEDITRACK. Royal Children s Hospital

Mediclean Complanate Ultra Clean Ventilation

... heat for you. Flat panel and decorative radiators

Trelleborg en g INeereD SYSTeMS Marine Fenders

MANUAL INSTALLATION. Active Chilled Beam Linear. ACBL Series. v101 Issue Date: 04/10/ Price Industries Limited. All rights reserved.

style with efficiency

Pipe gasket range. Designed to make a difference. Designed to make a difference 1

LPCB LPS 1175 APPROVED PRODUCTS

PANIC EXIT DEVICES.34

Heradesign fine Product Data & Certificates

Centrifugal Cabinet Fans Model BDF. Belt Drive Duct Fan

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Know-how. and innovation at your service. Transition. profiles. Stopping. profiles. Stair nosing profiles and stair tread inserts. Protection profiles

Innovations. Supplement to Eldon Product Catalogue

Energy saving ventilation Air handling units (Catalogue no. 2) Industrial and commercial ventilation. (Catalogue no. 1)

ADDRESSING CHALLENGES AROUND FOOD GRADE GREASE PRODUCTION. ICIS FOOD GRADE LUBRICANTS 23 rd September 2014 in Berlin

GP Lam LVL. (20!and 22! by special order) 13 4! 31 2! 1.5E. Lengths: up to 60 feet. Referenced dimensions are nominal and used for design purposes.

ISSUE B, OCT Architectural Square Ceiling Diffusers. UNI & AUNI Diffusers. Advanced Air

PROBE LOCKER DIGEST MEETS BS 4680:1996. We reserve the right to alter specifications without prior consent.

CONTENT VIPP LAMPS : TIMELESS ILLUMINATION 4-5 IMPORTANT SAFETY INSTRUCTIONS 6-8 VIPP521 TABLE LAMP VIPP522 WALL LAMP 16-23

C O L M A N. Air Distribution LINEAR BAR GRILLES T SERIES SERIES

Air displacement diffusers - p 202. Diffusers with rotating nozzle - p 215. Alum jet diffusers - p 221. Steel jet diffusers - p 225

Schüco Premium Collectors Outstanding quality, performance and design

SHOWER SCREEN CATALOGUE

4 Door Closers Ä o ²»

Section K. Cabtray - Cable Management System

... heat for you KORALUX. towel rail radiators - technical catalogue

WINDOW VENTILATION High quality, customisable, Surface Mounted and Glazed In options

Manufacturing Quality Control of High-Pressure Composite Cylinders by Acoustic Emission

Elegant-wall 19inch wall mounting rack cabinet W:600 = D:600

Heradesign superfine Product Data & Certificates

Components, Mounting Systems, In-roof PV Solutions FATH Solar About us Page 3

LINEAR SLOT DUFFUSERS

Slot diffusers for ceiling installation

Rail Hoses. The Hose Range for European Rail Transportation

Standard Stock Range. The UK s largest independent multi-metals stockholder.

Exceeding the standards with MNS

Ceiling products Acoustic performance data

Type DCS FOR HORIZONTAL SWIRLING SUPPLY AIR DISCHARGE CREATING HIGH INDUCTION LEVELS, WITH FIXED AIR CONTROL BLADES

STORAGE DESIGN LIMITED TEL: PROBE LOCKER DIGEST

Multideck 60-V2. Contents

Opening Doors Worldwide! TORMAX REVOLVEDOOR Turn System

DieMax XL TM Maximum Life Springs

series Linear grilles

Metal enclosed capacitor banks: ABBACUS family

Table of Contents. Wire Cable Tray. Underfloor. Accessories. Index. pages 1-9. pages pages pages pages

Designed to prevent condensation and energy losses

Ceiling swirl diffusers with perforated face plate

VEHICLE COMPONENTS SUPPLY EXPERTS

AUTOMOTIVE SHAPING ESSENTIAL SOLUTIONS

MATERIAL HANDLING RECYCLING FOOD & PHARMA WORKHOLDING CONVEYING QUICK MOULD SHEETING FILTRATION DEMAGNETIZERS & METERS

About Supply Plus Ltd

Folding door system: WingLine L

Hahn Serie 60 AT. Universal hinge for versatile application. More modern look Improved technology

REBAR CONNECTION SYSTEM

ROL NOZZLE DUCT ROL-S ADJUSTMENT AND SILENCER UNIT

Transcription:

CEILING&WALL SYSTEMS CI/SfB (35) Xy September 2012 Between us, ideas become reality Suspension Systems catalogue 2013 / 2014

S UMMARY ARMSTRONG SUSPENSION SYSTEMS Armstrong s Philosophies 1 Armstrong s Commitment to the Environment 2 CE Marking 3 Armstrong Projects 4 The Range 5 TECHNICAL INFORMATION 6 22 Fire Tests 16 Load Capacity Matrix 20 PRODUCT RANGE DESIGN OPTIONS Axiom Transitions 22 Axiom Profiles 24 Axiom Classic Canopy 26 Axiom Knife Edge Canopy 28 Axiom Circle & Curved 30 Silhouette 15 XL 2 32 Interlude 15 XL 2 34 environment quality/ce marking product innovation service Designed for fast and easy installation GENERAL APPLICATIONS Prelude 15 36 Prelude 24 XL 2 38 Prelude 24 TLX 40 Prelude Sixty 2 42 Prelude 35 XL 2 44 Bandraster 46 System Z 48 CORRIDOR Prelude Sixty 2 50 SPECIFIC APPLICATIONS Clean Room 24 mm Grid System 52 Corrosive Resistant 24 mm Grid System 54 Seismic Solution 56 LongSpan System 58 PERIMETER TRIM AND ACCESSORIES Flexible Perimeter Trim 60 Perimeter Solutions Mineral Ceilings 62 Perimeter Solutions Metal Ceilings 64 Accessories 66 www.armstrong.eu

ARMSTRONG S PHILOSOPHIES TOTAL CEILING SOLUTIONS The suspension system product range forms an integral part of Armstrong s total ceiling solutions policy. Armstrong now offers its customers and specifiers a complete range of ceiling panels including mineral, soft fibre, wood and metal and a wider choice than ever of suspension systems. Armstrong can provide solutions for all elements in today s challenging construction environments. QUALITY Suspension systems are manufactured for Armstrong both by its joint venture company WAVE (Worthington Armstrong Venture) and through various alliances with other companies who are regarded as specialists in their fields of engineering. WAVE operates on a global basis, and brings to its various European operations world class practice on the most technologically advanced equipment. SERVICE Suspension systems are manufactured in three European plants, strategically located to serve all our European customers. Additionally, both Armstrong and WAVE can draw upon their global manufacturing capabilities for both speciality products and manufacturing support. In addition to WAVE s manufacturing sites, Armstrong stocks suspension systems in distribution centres throughout Europe. This allows our customers the convenience of mixed product shipments, combining suspension systems with other Armstrong ceiling products, optimising bulk shipments direct from their manufacturing locations. WAVE WAVE has three manufacturing locations in Europe, three in the USA including the facility in Aberdeen, Maryland which is one of the world s largest grid facilities, plus one in China. INTEGRATION Suspension systems are designed for integration with Armstrong's portfolio of ceiling products, mineral, soft fibre, metal, wood and special solutions. TEAM VALLEY STAFFORD VALENCIENNES MUNSTER MOSCOW BENTON HARBOUR ABERDEEN / MALVERN PONTARLIER MADRID RANKWEIL LAS VEGAS SHANGHAI MUMBAI Metal ceiling plants Mineral fibre plants Grid plants Distribution centres 1

ARMSTRONG S COMMITMENT TO THE ENVIRONMENT Our environmental efforts in the lifecycle of our products start with design. fi fi DESIGN Innovative design creates stronger sections. Reuse of waste materials Raw materials for ceilings are renewable and abundant in nature. Recycled content varies by product: Suspension system contain 25% postconsumer recycled content fi MANUFACTURING Suspension system Main Runners and Cross Tees are rotary stitched by a patented method to deliver extra strength and stability. All in process scrap is recycled back into the process. Suspension systems and panels are manufactured at several locations, thereby reducing transportation costs and environmental impacts associated with transportation. RECYCLE Suspension systems contain up to 25% postconsumer recycled content End of Life ceiling tile recycling scheme. INSTALLATION Integrate technology to reduce installation time. Optimised packaging material less waste on site. Up to 100% of the packaging is made from recycled material. fi In several countries, we support the recollection of packaging. RETHINK PRODUCTS Continuous development of innovative thin gauge products. fi fi WARRANTY ON USE A history of quality products. Various warranty options are available on ceilings systems. MAINTENANCE Minimal maintenance and easy to replace. Armstrong has an expanding portfolio of sustainable products, these include: > Hotdipped galvanised suspension systems provide superior resistance to rust and corrosion. fi 2 www.armstrong.eu

CE Marking What is it? CE stands for Conformité Européenne, which translated literally, means European Conformity. The CE mark is a products passport for entry into the EEA (European Economic Area) and indicates that the product complies with the requirements of the applicable European Directive. For construction products the European Directive is the Construction Products Directive (89/106/ EEC), however, this is being replaced by the Construction Products Regulations (305/2011/EU) which will come into full force on 1st July 2013. The CPD identifies the essential requirements for products (and total projects) such that they are fit for intended use as: mechanical resistance and stability; safety in case of fire; hygiene, health and environment; safety in use; protection against noise; energy economy and heat retention. For suspended ceilings, the way in which we must test and communicate performance for these essential requirements has been defined in EN 13964 Suspended Ceilings Requirements and Test Methods. What does this mean? This standard identifies how the ceiling components must be tested against the essential requirements to identify a performance classification. It also indicates how the manufacturer must ensure that their products maintain these levels of performance on an ongoing basis. On 1st July 2007, it became mandatory for all suspended ceilings and accompanying suspension systems (in the scope of EN 13964) to carry the CE mark and the accompanying essential requirement test information. Since 1st July 2007, nonce marked materials are no longer saleable into the EEA. BRE BUILDING RESEARCH ESTABLISHMENT At Armstrong, we re proud to be a recognised pioneer in green practices, with successful methods to produce environmentally preferable products, prevent pollution and reduce waste. We re the only UK ceiling manufacturer with a BRE Ecopoint profile an external certification of our compliance with ISO 14041 and ISO 21930 standards. Our Ecopoint score in 2007 was 0.10, a significant improvement on 2004, and we re working on lowering it even further. 3

ARMSTRONG PROJECTS Armstrong World Industry (USA) Axiom Circle Canopy Uttoxeter Cinema (UK) Coloured Prelude 24 4

Concordia Hotel (IT) Axiom C Canopy Dutch Technology Leiden (NL) System Z Medis Office (SI) Silhouette Hospital Ruzomberok (SK) Clean Room Grid. Telefonica Center (SP) Bandraster Lothar Meyer School (DE) 5

THE SUSPENSION RANGE The suspension systems include a full range of solutions for all ceiling suspension requirements. General applications, a range of standard Prelude 24mm and Prelude 15mm grid systems, Bandraster and Prelude Sixty 2 for longer spans. Drywall Grid Systems are available for plasterboard ceilings. Designer options including the minimalist grid Silhouette, Interlude and the Axiom range. Specific applications, for clean room and higher humidity environments. Perimeter trims and accessories, for most applications. We also include our comprehensive programme of special size options that is available in most ranges. A range of either stab or hook systems are available to meet the mechanical preferences of the installer. To complete the portfolio we also offer a technical test programme that provides fire, loadings and environmental accreditation. Suspension systems are designed for use with a wide variety of Armstrong ceiling products, mineral, soft fibre, metal, wood and special solutions. Peakform is an innovative design for Main Runners and Cross Tees. The taller Peakform profiles are engineered to create a stronger, more stable suspension system making installation both faster and easier. Superlock is an industry first stakedon clip for Main Runners which provides tighter, secure bulbtobulb connections; connections are confirmed by an audible click; Main Runners are easily disconnected and reconnected laterally. 6 www.armstrong.eu

W HER E INNOVATION MEETS P ER F OR MANCE VOICE OF THE CUSTOMER Customer input is an extremely valuable part of our product innovation progress. Armstrong hold regular voice of customer work sessions to help develop the most innovative products and systems to meet the customer s needs. HOT DIPPED GALVANIZED STEEL: Inhibits red rusting better and longer than electro galvanised or painted systems Installation of grid can start before the building is enclosed or HVAC system is operational. Long term system performance because entire system is hot dipped galvanised steel. THIN GAUGE TECHNOLOGY: Up to 50% lighter carton weight than the competition enables easier handling on site, plus the added benefit of the Peakform bulb allows easy cutting of the grid. OTHER SYSTEMS Our extensive range of performance grids also includes Bandraster, Prelude Sixty 2, Prelude 35, System Z and LongSpan. Specific grid solutions such as Clean Room Grid, Seismic Grid and Corrosive Resistant grid completes Armstrong's suspension solutions. PHYSICAL DETAIL All grids are made from doubleweb galvanised steel with a surface finish of baked polyester paint. STITCHING All Prelude components feature a unique stitched construction. The two metal layers of the vertical web are mechanically locked together in a sophisticated inline process. Stitching enhances the torsional resistance and general feel of the Prelude components. DESIGNER GRIDS Armstrong s designer range, Silhouette, Interlude, Axiom System and Axiom Canopies provide aesthetically enhanced grids. Silhouette creates a level ceiling surface, providing a flush appearance while Interlude gives a clean sophisticated visual that is created by the unique double reveal. Axiom Profiles and Transitions provide an aesthetic solution for changes in level and a flush transition with plaster margins. Axiom Canopies are a perimeter trim system designed to create ceiling clouds in conjunction with full size tiles. FULL RANGE OF ACCESSORIES AND PERIMETER SOLUTIONS Suspension systems are offered with a complete range of commonly required accessories and perimeter solutions. 7

AR MSTR ONG SYSTEMS PRELUDE UNIVERSAL MAIN RUNNER The Prelude Universal Main Runner supports the installation of either hook/butt cut or stab/override Cross Tees from one simple inventory of Main Runners. The universal system is available in Peakform design in both 24mm and 15mm widths. The Peakform Universal Main Runners feature a firm, quick and easy assembled Main Runner to Main Runner / bulbtobulb connection. Metric sized Main Runners are slotted at 100mm centres for more flexibility. Slots are machined to receive positive and accurate assembly of either Prelude TL and TLX (hook installation) or Prelude XL 2 (stab installation) Cross Tees. The stakedon Superlock clip allows for Main Runners to be disconnected and reconnected laterally in lowclearance areas or in the middle of a room. TL TLX PRELUDE XL 2 W HER E INNOVATION MEETS P ER F OR MANCE SEISMIC Rx SYSTEM Armstrong Seismic Rx System is a fully and independently tested approach to achieving ceiling installations that can withstand the forces associated with significant seismic activity or other severe events. In addition to earthquakes, there are several other industries with associated risks (e.g. Blast protection) where the use of Seismic Rx System will provide additional protection for the ceiling e.g. Nuclear installations Defence establishments Chemical installations Transport installations (with intermittent vibrations) The Seismic Rx system provides the additional security required for seismic resistance using specifically designed elements for minimised installation complexity with maximum performance. 8 www.armstrong.eu

PRELUDE XL 2 CLICK INSTALLATION Prelude XL2 Cross Tees in both 24mm and 15mm widths feature an advanced stab system that locates with an audible click, ensuring a solid installation at all times. The stab end is precision stamped from a separate piece of high grade steel permitting an increased accuracy and economy of production over the more conventional integral forming of the Cross Tee ends. A selected range of standard Prelude 15/24 XL2 Cross Tees feature the new Peakform design. The Cross Tees are inserted to the right of each other through the Main Runner slots and easily pushed home. PRELUDE TLX TLX is a new highly engineered stakedon hook system, with a patented clip. Its unique steelbased composite material and shape provide a stronger and level connection, an improved fire performance and an increased overall stability.tlx Cross Tees are quicker and easier to cut due to the Peakform section. When the TLX Cross Tees are inserted to the right of each other through the Main Runner slots, the TLX clip provides a more secure installation. PRELUDE TL HOOK INSTALLATION Prelude TL Cross Tees in 15mm width feature an integrally formed hook nose. This popular installation system has been a feature of Armstrong suspension systems for over 20 years and its proven ease of assembly and precise butt cut joint has been a favourite of installers. Cross Tee alignment is ensured by locating the tees to the right hand side of the adjoining section. 9

STANDARD COLOURS Armstrong suspension system components are manufactured in a range of colours and metal finishes including Global White to complement Armstrong ceiling tiles. For complete information call Internal Technical Sales. GLOBAL WHITE SILVER GREY CARRARA PLATINUM BLACK WHITE GLOBAL WHITE BRASS CHROME WHITE GALVANISED BLACK/WHITE (GW) RAL 9006 (SG) (CA) (PN) (BK) RAL9010 (WR) (GW) (BS) (CE) RAL9010 (WR) Prelude 24 TLX Prelude 24 XL 2 Prelude 15 XL 2 /TL Silhouette XL 2 6mm Silhouette XL 2 3mm Interlude Bandraster Prelude 35 Prelude Sixty 2 Corrosive Resistant Clean Room Grid Axiom System Steel based capping Other than Steel based Painted perimeter trim items are available in Global White and capped angle T 1924 CA is available in all colours except black/white and galvanised. Please contact Internal Technical Sales Group for further details. 10 www.armstrong.eu

COLOUR PALLET Stimulate your imagination to create vibrant interior spaces using custom colour solutions. Choice of more than 180 custom colours upon request. Available for Prelude 15 and Prelude 24 and specific perimeter trims. DETAILS 15 mm Cross Tee and Main Runner 24 mm Cross Tee and Main Runner 15mm 24mm Colour Selection Due to printing limitations, shade may vary from actual product. RAL 1000 RAL 1001* RAL 1002 RAL 1003 RAL 1004 RAL 1005 RAL 1006 RAL 1007* RAL 1011 RAL 1012 RAL 1013* RAL 1014 RAL 1015* RAL 1016 RAL 1017 RAL 1018 RAL 1019* RAL 1020 RAL 1021* RAL 1024 RAL 1027 RAL 1028 RAL 1032 RAL 1033 RAL 1034 RAL 2000* RAL 2001 RAL 2002* RAL 2003 RAL 2004* RAL 2008 RAL 2010 RAL 2011 RAL 2012 RAL 3000* RAL 3001 RAL 3002* RAL 3003 RAL 3004 RAL 3005 RAL 3007 RAL 3009 RAL 3011 RAL 3012 RAL 3013 RAL 3014 RAL 3015 RAL 3016 RAL 3017 RAL 3018 RAL 3022 RAL 3027 RAL 3031 RAL 4001 RAL 4002 RAL 4003 RAL 4004 RAL 4005 RAL 4007 RAL 4008 RAL 4009 RAL 5000 RAL 5001 RAL 5002 RAL 5003* RAL 5004 RAL 5005 RAL 5007 RAL 5008 RAL 5009* RAL 5010* RAL 5011 RAL 5012* RAL 5013 RAL 5014 RAL 5015* RAL 5018 RAL 5019 RAL 5020 RAL 5021 RAL 5022 RAL 5024 RAL 6000 RAL 6001 RAL 6002 RAL 6003 RAL 6004 RAL 6005 RAL 6006 RAL 6007 RAL 6008 RAL 6009 RAL 6010 RAL 6011* RAL 6012 RAL 6013 RAL 6014 RAL 6015 RAL 6016 RAL 6017 RAL 6018 RAL 6019 RAL 6020 RAL 6021 RAL 6022 RAL 6025 RAL 6026 RAL 6027 RAL 6028 RAL 6029 RAL 6032 RAL 7000 RAL 7001* RAL 7002 RAL 7003 RAL 7004 RAL 7005 RAL 7006 RAL 7008 RAL 7009 RAL 7010 RAL 7011 RAL 7012* RAL 7013 RAL 7015 RAL 7016* RAL 7021* RAL 7022 RAL 7023 RAL 7024 RAL 7026 RAL 7030* RAL 7031* RAL 7032* RAL 7033 RAL 7034 RAL 7035* RAL 7036 RAL 7037 RAL 7038* RAL 7039 RAL 7040* RAL 7044* RAL 8000 RAL 8001 RAL 8002 RAL 8003 RAL 8004 RAL 8007 RAL 8008 RAL 8011 RAL 8012 RAL 8014* RAL 8015 RAL 8016 RAL 8017 RAL 8019* RAL 8022 RAL 8023 RAL 8024 RAL 8025 RAL 8028 RAL 9001* RAL 9002* RAL 9003* RAL 9004 RAL 9005* RAL 9010* RAL 9011* RAL 9018* RAL 1023 RAL 2009 RAL 3020 RAL 4006 RAL 5017 RAL 6024 RAL 7042 RAL 7043 RAL 9016* RAL 9017 *Matt finish items are available as a special order. RAL CLASSIC: Important notice: This ORIGINAL RAL colour chart (card) has gone through stringent quality testing by RAL. Only the use of the individual cards of the registers RAL 840HR (semi matt finish) and RAL 841GL (gloss finish) will guarantee a reliable manufacture and control of RAL Colours. 11

PRODUCT SELECTOR by application areas Area Suspension system solution Open spaces Reception areas Meeting rooms / Individual offices Circulation areas Axiom Canopy (C/KE/Circle/Curved) Axiom Transitions Bandraster Axiom Transitions Axiom Profiles Silhouette 15 mm Interlude 15 mm Prelude 24 mm Prelude 15 mm System Z MicroLine 15 mm Prelude Sixty 2 Retail outlets / industrial manufacturing Prelude 35 XL 2 Humid areas Healthcare environments Prelude 24 Corrosive Resistant Clean Room Grid PRODUCT SELECTOR by edge detail compatibility Axiom Silhouette Interlude Prelude Prelude Prelude Prelude Sixty 2 Prelude Clean Room Corrosive Bandraster System Z Transitions/Profiles 15 15 24 XL 2 24 TLX 35XL 2 Resistant Mineral Vector MicroLook MicroLook BE Tegular Board SL2/K2C2 Metal Metal Axal Vector Metal MicroLook 8 Metal MicroLook 16 Metal Tegular 2 Metal Tegular 8, 11F or 16 Metal Board 12 www.armstrong.eu

TECHNICAL ICONS Colour Pallet Peakform Accessories Perimeter Trim Corridor Specific applications / healthcare environment Design Grid General applications 13

HEALTH AND CLEANLINESS Did You Know...? It s all about Air Quality control: The air penetrating the Clean Room can be filtered depending on the size of the undesired elements. Air can be recycled up to 60 times per hour for the total volume of the space. New air is also introduced to avoid a build up in the concentration of CO 2 and maintain enough oxygen for the people working there. Operators in a clean room have to wear equipment such as a clean room suit, hair cover, gloves, shoeprotection, or mask. There are 2 types of rooms: rooms with overpressure, to avoid pollutants from entering (dust, bacteria, ) rooms with negative pressure, to avoid various contaminants from escaping to the outside (viruses, bacteria, spores, ). Building materials used in such spaces shall not have a negative impact on the pursuance of cleanliness and should preferably contribute actively to a better CLEAN ROOM A Clean Room is a space or a series of spaces where the concentration of particles is controlled in order to minimise the introduction, generation, retention of particles inside, generally for a specific industrial or research objective, as well as in healthcare environments. Parameters such as temperature, humidity and relative pressure are also maintained at a precise level, as defined in ISO 146441. Clean rooms are classified ISO 1 (cleanest) to ISO 9 depending on the number of particles measured. The performance is tested to ISO 146441 which determines the particle cleanliness class. Although US Federal Standard 209E has been officially withdrawn, it is continuously used as a reference. The following table shows the equivalence between the 2 standards. ISO Class Maximum Number of Particles in Air (particles in each cubic metre equal to or greater than the specified size) Particle size > 0.1µm > 0.2 µm > 0.3 µm > 0.5 µm > 1 µm > 5 µm ISO Class 1 10 2 ISO Class 2 100 24 10 4 ISO Class 3 1 000 237 102 35 8 Class 1 ISO Class 4 10 000 2 370 1 020 352 83 Class 10 ISO Class 5 100 000 23 700 10 200 3 520 832 29 Class 100 ISO Class 6 1 000 000 237 000 102 000 35 200 8 320 293 Class 1 000 ISO Class 7 352 000 83 200 2 930 Class 10 000 ISO Class 8 3 520 000 832 000 29 300 Class 100 000 ISO Class 9 35 200 000 8 320 000 293 000 Class 1 000 000 HEALTHCARE PREMISE In healthcare premises, it is of critical importance to avoid hospital acquired infections. According to the level of risk, the necessary clean room performance will vary, generally between ISO 5 and ISO 8. All products below: can be used in ISO 5 environments and are certified against ISO 146441; inhibit growth of bacteria, moulds and yeasts tested against norms NF S 90351, France, and JIS Z2801, Japan. Some examples of spaces and system solutions: US Federal Standard 209E TYPE OF SPACE CONSTRAINTS SYSTEM SOLUTION* LEVEL OF PERFORMANCE Operating Theatre Fully airtight Metal Bioguard Plain ClipIn ISO 3 Flush surface finish with appropriate silicone or mastic joint High pressure water cleanable Antimicrobial MRI Nonmagnetic CLEAN ROOM grid with plastic ISO 5 holddown clips & Clean Room FL Antistatic Antimicrobial CLEAN ROOM grid with plastic ISO 5 holddown clips & Bioguard Acoustic Bioguard treatment Intensive Care Antimicrobial Clean Room grid with plastic holddown ISO 5 Wakeup Room Good airtightness clips Bioguard Acoustic or Metal Bioguard Washable Maternity Good acoustical environment Extra Microperforated Rg 0701 with 0.65 w sound absorption Laboratory Premium B15 Pharmacy * Subject to local regulations. Please check with your Armstrong Technical Sales. 14 www.armstrong.eu

Did You Know...? System solutions for the Pharmaceutical, Food and Manufacturing Industry can be found in our brochure Solutions for Clean Room Environments. BIOGUARD products have been especially designed for the healthcare sector. The BIOGUARD paint treatment has additional active components which reduce the colony size of virulent strains of bacteria, moulds and yeasts. BIOGUARD products achieve ISO 5 to ISO 3 in accordance with ISO 146441. BIOGUARD paint has enhanced resistance to disinfectants. Grid and tiles for Clean Room environments GRID MINERAL METAL Clean Room Bioguard Bioguard Clean Room FL Metal Bioguard Metal Bioguard Grid Plain Acoustic Extra Plain Microperforated Rg 0701 with Premium B15 Classification Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2 & 3 Zone 1, 2, 3 & 4 NF S 90351 Particle ISO 4 ISO 5 ISO 5 ISO 5 ISO 5 ISO 3 cleanliness class Material Aluminium Mineral Mineral Mineral Steel with mineral Steel acoustic infill Surface PVC Bioguard paint Glass veil with Polyester film EXTRA PLAIN Bioguard paint MICROPERFORATED with Bioguard Rg 0701 with polyester powder Bioguard polyester paint powder paint Resistance Quaternary Ammonium, Hydrogen Peroxide, Chlorine * Quaternary Ammonium, to disinfectants* Hydrogen Peroxide, Chlorine * Not tested 15

FIRE PERFORMANCES REACTION TO FIRE The harmonisation of technical standards within Europe, and the integration of EN13964 (Suspended ceilings requirements and test methods) into national legislation, means that there is now one series of harmonised European test methods and classifications for the reaction to fire of suspended ceilings. These new reaction to fire classifications, or Euroclasses, are defined in EN135011:2007. The Euroclasses have replaced the old national fire reaction ratings for showing the performance of ceilings in order to meet the Construction Products Directive and national building regulation requirements for internal linings. As reaction to fire is one of the essential safety requirements identified for suspended ceilings, the Euroclass classification is one of the mandatory elements on the CE mark for suspended ceiling tiles and grids. The Euroclasses rate from A1 through to F, with A1 being the best reaction to fire performance and F the worst. Each member state then sets the performance level required for different areas and building types within their own building regulations. Depending upon the reaction to fire test(s) conducted, the rating may include an additional classifications for smoke production and flaming droplets. Smoke and flaming droplets are regulated in some European countries. Smoke production is rated from s1 (the least smoke produced) to s3 (no limit to amount of smoke produced). Flaming droplets is rated from d0 (no flaming droplets) to d2 (no limit to flaming droplets). STRUCTURAL FIRE PROTECTION Throughout Europe, there is a requirement for a building s structure to be protected from fire. This is primarily for the structure to remain stable during a fire to allow the occupants to escape and also to enable fire fighters to work without threat of the building s collapse. The duration of the required protection will usually depend upon the height of, and location within, the building (i.e. typical floor, basement, roof construction etc), whether there is any active methods of fire protection (sprinklers etc) and the type of construction to be protected (steel beams, timber or mezzanine floors etc). A fire protecting suspended ceiling system is one of several important methods of providing the fire protection which fire degradable elements of the structure require. Ceilings can be used to enable a floor construction to meet the duration of protection required by the building regulations that it could not necessarily provide on its own. There are many national test methods for establishing the structural fire protection performance of a suspended ceiling system, as well as several European norms which are acceptable in most European countries. The performance achieved during testing will be classified in terms of the duration of protection given, typically this in accordance with EN135012:2007 for European tests. However, there is not yet one single European test method which is acceptable to all member states. Untested products may be assessed by reference to the product attributes and comparison to similar tested products, provided this is supported by an assessment report from a recognised fire expert and should be provided with the base test report that details how the product should be installed to achieve the assessed performance. The location and type of various service elements such as lighting fittings, smoke detectors etc, are infinite and the designer and installer must satisfy themselves that they can be integrated without reducing the tested performance of the ceiling system. This will usually require a test report from the fitting manufacturer or an assessment issued by the fire authorities. Without these documents the designer or installer may assume an everlasting responsibility for the fire safety of the building and occupants. The complete construction and assembly of the test installation is important to the success of the test, and Armstrong test many ceiling tiles for their structural fire performance, but always on Armstrong grid. There are many other details of the test construction that must be understood and adhered to. These include: main runner and hanger centres the type of top fixings and how the hangers are attached to them the minimum depth of the ceiling void what % of the floor design load is tested whether ceiling tile holddown clips were used. These details must be included in the installation if the tested performance is to be realised and they should be taken into account when writing specifications for ceilings intended to provide structural fire protection. In the UK the fire performance of floor structures protected by Armstrong ceiling tile and grid systems is given in the fire assessment document 173816. This document is based on a large number of fire tests conducted on various Armstrong ceiling tile and grid types. It provides an assessment of the performances attainable when various Armstrong tile and grid systems are installed in accordance with the appropriate base fire test and the permitted installation variations from that base test. The tables opposite give a summary of the performances achievable as stated in the assessment document and are correct at the time of going to print. As products may be modified or retested it is essential that their validity is always checked prior to installation. Therefore, the current version of the assessment document 173816 and the relevant base test report should always be consulted prior to the installation of a floor construction to be protected by an Armstrong ceiling system. A full document is always required and must be read and any limitations understood. Abridged versions must be regarded as undesirable as they will not show the full test details and construction. All Armstrong classification documents are freely available on request from our Internal Technical Sales team. 16 www.armstrong.eu

Assessed Performance Under Structural Steel Beams Base Test Report: 134086 (70995 for ClipIn) Board Tegular MicroLook Tegular 2 ClipIn 3mm Comments Ultima 90 minutes 60 minutes 60 minutes n/a n/a Includes 500 x 500 and 1200 x 300 MicroLook Ultima Ultima db 60 minutes 60 minutes 60 minutes n/a n/a Ultima OP 30 minutes n/a n/a n/a n/a Perla 60 minutes 60 minutes 60 minutes n/a n/a Perla OP 30 minutes n/a n/a n/a n/a Sierra 60 minutes 60 minutes 60 minutes n/a n/a Bioguard Acoustic / Bioguard Plain 60 minutes 60 minutes 60 minutes n/a n/a Fine Fissured 60 minutes 60 minutes 30 minutes n/a n/a Includes Colortone Black Plain 60 minutes 60 minutes 30 minutes n/a n/a Does NOT include Graphis Cirrus 60 minutes 60 minutes 30 minutes n/a n/a Does NOT include Cirrus Image tiles Metal Plain + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m 3 AFBTF* pad Metal Standard Perforated Rg 2516 + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m 3 AFBTF* pad Metal Microperforated Rd 1522 + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m 3 AFBTF* pad Metal Extra Microperforated Rg 0701 + Premium B15 or PAD 60 minutes 60 minutes 60 minutes 60 minutes n/a 8mm and 16mm returns. 18mm 100kg/m 3 AFBTF* pad Metal Plain + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m 3 AFBTF* pad Metal Standard Perforated Rg 2516 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m 3 AFBTF* pad Metal Microperforated Rd 1522 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m 3 AFBTF* pad Metal Extra MicroperforatedRg 0701 + PAD n/a n/a n/a n/a 30 minutes 600 x 600 only. 40mm 45kg/m 3 AFBTF* pad Assessed Performance Under Timber Floors Base Test Report: 167751 Board Tegular MicroLook Tegular 2 ClipIn 3mm Comments Ultima 60 minutes 60 minutes 60 minutes n/a n/a Ultima db 60 minutes 60 minutes 60 minutes n/a n/a Main runners at 600mm centres only Ultima / Ultima db 30 minutes 30 minutes 30 minutes n/a n/a Perla 30 minutes 30 minutes n/a n/a n/a Sierra 30 minutes 30 minutes n/a n/a n/a Bioguard Acoustic / Bioguard Plain 30 minutes 30 minutes n/a n/a n/a Fine Fissured 30 minutes 30 minutes n/a n/a n/a Includes Colortone Black Plain 30 minutes 30 minutes n/a n/a n/a Does NOT include Graphis Cirrus 30 minutes 30 minutes n/a n/a n/a Does NOT include Cirrus Image tiles Assessed Performance Under Mezzanine Floors Base Test Report: 120559 Board Tegular MicroLook Tegular 2 ClipIn 3mm Comments Ultima / Ultima db 60 minutes 60 minutes 30 minutes n/a n/a Perla 30 minutes 30 minutes n/a n/a n/a Sierra 30 minutes 30 minutes n/a n/a n/a Bioguard Acoustic / Bioguard Plain 30 minutes 30 minutes n/a n/a n/a Fine Fissured 30 minutes 30 minutes n/a n/a n/a Includes Colortone Black Plain 30 minutes 30 minutes n/a n/a n/a Does NOT include Graphis Cirrus 30 minutes 30 minutes n/a n/a n/a Does NOT include Cirrus Image tiles *AFTBF = an aluminium foil, black tissue faced acoustic pad 17

INSTALLATION & MAINTENANCE SAFETY Armstrong s commitment on safety concerns each and every step of our business: in our plants & offices, we have implemented rigorous safety policies and procedures to help minimise risk for our products, for which we ensure compliance with appropriate European and local safety regulations. on the jobsite, safety is crucial for our partners: Armstrong therefore recommends the handling, installation & maintenance of our solutions in accordance with the Standards and / or regulations, for the safety of the installers & of the end users. GENERAL ADVICE Installation of suspended ceiling systems should be carried out in accordance with Armstrong's current manufacturer's recommendations. For grid systems there are some specific points that should be considered: The appropriate type of Cross Tee for the ceiling tile edge detail must be considered. The grid systems should be installed in such a way that the loadbearing performance of the grid is not exceeded. 'Dynamic' service fittings should be independently supported so not to transfer vibration into the suspension system. Armstrong recommend the use of the 'ladder formation' and all our loading data is based on the 'ladder formation'. Using the 'Hformation' will give greater deflection for a given load. Ladder formation H formation Yes No 18 www.armstrong.eu

INSTALL ATION & MAINTENANCE 1 B 2 3 A 600 1000 A 800 B 1. Planning grid layout 2. Mark the perimeter trim lines 3. Installation of perimeter trims 4 Max 600 mm 5 6 1200 mm 1200 mm B (Main Runner) B (Main Runner) 4. Mark hanger positions 5. Installation of hangers 6. Positioning Main Runner slots 7 8 9 7. Installation of Main Runners 8. Cross Tees installation right to right 9. Cutting Cross Tees 10 11 12 10. Installation of tiles 11. Measure and cut perimeter tiles 12. Retegulating Tegular or MicroLook tiles POST INSTALLATION After the installation of a suspended ceiling system it is important to ensure that it is properly maintained and that any additional works are not detrimental to the performance of the ceiling installation. Maintenance operations must only be undertaken after the technical impact on the ceiling system has been completely evaluated. For example, hangers should not be removed, adapted or bent without fully understanding the consequences and taking any appropriate mitigating actions. Armstrong suspension systems do not need any more maintenance than normal painted metal surfaces. However, if cleaning is required dust and superficial dirt can easily be removed with a soft brush or a vacuum cleaner with a brush attachment. For more stubborn marks a lightly dampened cloth or sponge can be used, although never use abrasive products. Some companies specialise in chemical cleaning solutions. These should only be undertaken after a test on a small hidden area of grid proves acceptable. Most Armstrong suspension systems can be redecorated, however, consideration should be given to the effect on the fire reaction performance of the grid. Ceiling tiles should be removed, however, the grid can usually be painted in situ. If a firm of professional decorators is used, assurances should be sought that the necessary performances will be maintained. It should be noted that any repainting would invalidate Armstrong's warranty for the product. 19

LOAD CAPACITY MATRIX Loading is an important property of suspended ceiling grid systems both for the mechanical safety of the suspended ceiling and its visual appearance. In the EEA, table 6 of the suspended ceiling product standard, EN 13964:2004+A1:2006, defines 3 classes of deflection, the best being Class 1 which is L/500 (but no greater than 4mm). Class Maximun deflection in mm A 1 L B / 500 and not greater than 4,0 2 L B / 300 3 No limit A The maximun deflection is the accumulative value of the deflection of the substructure component and the deflection of the membrane component. B L is the span in mm between the suspension components or the suspension points. The test method on which the European calculations of loadbearing capacity are based upon is also defined in EN 13964, and considers the influence of both deflection and bending moment. The individual product pages in the second half of this brochure include a table giving the maximum uniform distributed load, based on different hanger centres, in accordance with Class 1 deflection, as defined in EN 13964:2004+A1:2006. For markets outside of the EEA different deflection limits are sometimes required. The tables on this page show the maximum uniform distributed load for the deflection limits shown, but taking into account deflection only. These values are calculated based upon load values determined from laboratory tests in accordance with the EN 13964 test method. For longer spans, some of the criteria shown on this page may give quite large deflection values. Armstrong recommends a maximum of 4mm deflection between points of suspension for all grid components, irrespective of span, for aesthetic reasons. Therefore the numbers in the tables on this page are the maximum loads permitted to meet the give a deflection criteria (such as L/400) but up to a maximum value of 4mm. System Load Summary (1200 x 1200 layout) Max Load kg/m 2 Deflection factor only System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee Prelude 24 XL 2 314032 A 313051 B 312021 A 13,3 16,8 18,8 22,7 22,7 Prelude 24 TLX 314032 A 133031 132031 13,3 16,8 18,7 22,7 22,7 Prelude 15 XL 2 304033 A 303033 B 302033 B 13,1 16,5 18,5 22,3 22,3 Prelude 15 TL 304033 A 103033 A 102033 A 13,1 16,5 18,5 22,3 22,3 Silhouette 15 XL 2 804042 G 803042 G 802042 G 11,4 14,4 16,1 19,5 19,5 Interlude 15 XL 2 614042 G 613042 G 612042 G 14,5 18,3 20,4 24,7 24,7 Prelude 35 XL 2 224042 243042 242042 13,9 17,7 19,8 24 24 Prelude 24 Corrosive Resistant TLX 284042 143032 142032 13,3 16,8 18,7 22,7 22,7 Clean Room 24 EA794044 EA793044 EA792044 12,8 16,3 18,2 22,1 22,1 1200mm spacing 600mm 1200mm Cross Tees MR MR 20 www.armstrong.eu

System Load Summary (1200x1800 layout) Max Load kg/m 2 Deflection factor only System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee Prelude 24 XL 2 (1800 span) 314032 A 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3 Prelude 24 TLX (1800 span) 314032 A 133432 132031 6,5 7,3 7,3 7,3 7,3 1200mm spacing 600mm 1800mm Cross Tees MR MR System Load Summary (1800x1800 layout) Max Load kg/m 2 Deflection factor only System Main Runner Primary Secondary L/500 L/400 L/360 L/300 L/250 Cross Tee Cross Tee Prelude Sixty 2 24 XL 2 404093 G 313431 A 312021 A 6,5 7,3 7,3 7,3 7,3 Prelude Sixty 2 24 TLX 404093 G 133432 132031 6,5 7,3 7,3 7,3 7,3 1800mm spacing 600mm 1800mm Cross Tees MR MR 21

Design Options AXIOM TRANSITIONS The 5 sections are designed to provide a flush transition between plaster margin and mineral, metal or wooden suspended ceilings. Axiom Transitions Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 50 8 T 3208 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36 Tegular/MicroLook 25 15 15 50 T 3219 G (1) Axiom Transitions channel 3000 50 10 30,00 17,10 36 25 15 19 15 50 T 3215 G (1) Axiom Transitions angle 3000 50 10 30,00 15,00 36 25 15 15 25 15 11 50 T 3210 G (1) Axiom Transitions for 3000 50 10 30,00 11,80 36 Vector tiles 25 15 35 15 T 3225 G (1) Axiom Transitions plasterboard 3000 50 10 30,00 11,30 36 perimeter trim Accessories for Axiom Transitions Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg 79 mm A 321 G Axiom Transitions suspension clip straight 79 100 2,10 62 mm A 322 G Axiom Transitions suspension clip angled 62 100 2,10 A 340 G Axiom universal corner clip 100 2,10 A 338 G Axiom universal splice plate 100 2,10 A 339 G Axiom universal T bar connector clip 100 2,10 A 344 G Axiom universal hanging clip 100 2,10 (1) Also available in colour RAL 9010 (WR). Note: As Axiom is an aluminium extrusion it should not be used in ceiling assemblies where structural fire protection is required. All measurements in millimetres. All sizes are nominal. 22 www.armstrong.eu

System Drawing AXIOM TRANSITIONS Design Options A 321 G A 322 G A 340 G A 338 G A 339 G 23

Design Options AXIOM PROFILES Available in 5 heights with a plasterboard trim section, Axiom Profiles are compatible with 24 mm and 15 mm grid systems including designer grid. Axiom Profiles 19 Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 52 42 06 G (1) Axiom Profiles 50 mm 3000 50 5 15,00 7,80 60 19 54 42 06 G (1) Axiom Profiles 100 mm 3000 100 5 15,00 11,20 36 19 200 56 42 06 G (1) Axiom Profiles 150 mm 3000 150 5 15,00 14,70 30 19 100 150 112 58 42 06 G (1) Axiom Profiles 200 mm 3000 200 5 15,00 17,80 24 50 55 14 11 G (1) Axiom Vector Profiles 112 mm 3000 112 5 15,00 12,20 15 T 3213 H (1) Profile plasterboard trim 3000 18,5 10 30,00 5,80 36 Accessories for Axiom Profiles Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg A 334 G (1) Axiom Profiles corner post 50 mm 50 2 0,30 A 335 G (1) Axiom Profiles corner post 100 mm 100 2 0,50 A 336 G (1) Axiom Profiles corner post 150 mm 150 2 0,70 A 337 G (1) Axiom Profiles corner post 200 mm 200 2 0,90 A 345 G (1) Axiom Vector corner post 112 mm 112 2 0,60 A 340 G Axiom universal corner clip 100 2,10 A 338 G Axiom universal splice plate 100 2,10 A 339 G Axiom universal T bar connector clip 100 2,10 A 344 G Axiom universal hanging clip 100 2,10 (1) Also available in colour RAL 9010 (WR) 24 www.armstrong.eu

System Drawing A 344 G A 334 G A 335 G A 336 G A 337 G A 345 G AXIOM PROFILES A 340 G A 344 G Design Options A 338 G A 339 G 200 A 100 (1) Also available in colour RAL 9010 (WR) 25

Design Options AXIOM C CANOPY Axiom C Canopy is a perimeter trim system designed to create ceiling clouds in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom C Canopy will define and individualise any space. Axiom C Canopy Components Item Nr. Description 55 14 11 G Axiom Vector MicroLook Tegular Profile 112 mm 112 mm C 3000 G Primary C channel A WDN 21 H T bar hanger Vector Tegular / MicroLook Cut to size Main Runner 600 mm XL 2 Cross Tees A 345 G Axiom Vector MicroLook Tegular Profile corner post 1.2m 3.0m 10 tiles 2.4m 1.8m 1.2m 8 tiles 6 tiles 4 tiles A 348 G Channel bracket 1.8m 15 tiles 12 tiles 9 tiles CA 97 G Clamp for C channel 2.4m 20 tiles 16 tiles A 347 G 24 mm XL 2 connector clip A 346 G 15 mm XL 2 connector clip 3.0m 25 tiles A 339 H Axiom universal T bar connector clip for cut tees with screws Axiom C Canopy Kits * Module Grid system 15 mm XL 2 Grid system 24 mm XL 2 Item Nr. Item Nr. 1200 x 1200 mm AX 22 G15 AX 22 G24 1800 x 1200 mm AX 32 G15 AX 32 G24 1800 x 1800 mm AX 33 G15 AX 33 G24 2400 x 1200 mm AX 42 G15 AX 42 G24 2400 x 1800 mm AX 43 G15 AX 43 G24 2400 x 2400 mm AX 44 G15 AX 44 G24 3000 x 1200 mm AX 52 G15 AX 52 G24 3000 x 1800 mm AX 53 G15 AX 53 G24 3000 x 2400 mm AX 54 G15 AX 54 G24 3000 x 3000 mm AX 55 G15 AX 55 G24 *Ceiling tiles are NOT included in the kit.! RECOMMENDATIONS Axiom C Canopy should always be installed in accordance with all applicable building codes and regulations. Axiom C Canopy should only be installed on a horizontal plane. They are not approved for exterior installations. Axiom C Canopy should always be installed by a minimum of 2 people. Read the installation instructions included in the carton carefully before starting the installation. Make sure the installation is clean and safe. Any additional weights (such as luminaires...) must be independently suspended from the soffit. Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing. All measurements in millimetres. All sizes are nominal. 26 www.armstrong.eu

System Drawing The 1800 mm x 3000 mm module is used as an example only. An installation instruction guide is available. Please contact our Armstrong Technical Sales for further details. AXIOM C CANOPY Design Options 4 Universal T bar connector clips 8 XL 2 connector clips 6 Aircraft cables & Gripple connectors 6 Universal T bar connector clips 4 Corner posts 4 Axiom profiles cut to size 6 Channel brackets 3 C channels cut to size 6 T bar hangers 12 Cross Tees 600 mm XL 2 (24 mm or 15 mm) 2 Main Runners cut to size (24 mm or 15 mm) OPTION 2 Quick hanger* OPTION 1 Aircraft cable & Gripple connectors OPTION 3 6 mm Threaded rod* * not included in the kit 27

Design Options AXIOM KE CANOPY Axiom KE Canopy is an aesthetic perimeter trim system designed to create ceiling clouds in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Axiom KE Canopy will define and individualise every space. Axiom KE Canopy Components Item Nr. CS 57 42 06 G Description Axiom KE Profile Tegular / MicroLook 106 mm C 3000 G A WDN 21 H Primary C channel T bar hanger 135 mm Cut to size Main Runner 600mm XL 2 Cross Tees Vector 106 mm CS 57 G Mitre corner piece 135 mm A 361 G Mitre corner splice connector 3.0m 2.4m 1.8m 1.2m A 348 G Channel bracket 1.2m 10 tiles 8 tiles 6 tiles 4 tiles CA 97 G Clamp for C channel 1.8m 15 tiles 12 tiles 9 tiles A 347 G 24 mm XL 2 connector clip A 346 G 15 mm XL 2 connector clip 2.4m 20 tiles 16 tiles A 339 H Axiom universal T bar connector clip for cut tees with screws 3.0m 25 tiles A 338 G Axiom universal splice plate Axiom KE Canopy Kits * Module Grid system 15 mm XL 2 Grid system 24 mm XL 2 Item Nr. Item Nr. 1200 x 1200 mm CS AK 22 G15 CS AK 22 G24 1800 x 1200 mm CS AK 32 G15 CS AK 32 G24 1800 x 1800 mm CS AK 33 G15 CS AK 33 G24 2400 x 1200 mm CS AK 42 G15 CS AK 42 G24 2400 x 1800 mm CS AK 43 G15 CS AK 43 G24 2400 x 2400 mm CS AK 44 G15 CS AK 44 G24 3000 x 1200 mm CS AK 52 G15 CS AK 52 G24 3000 x 1800 mm CS AK 53 G15 CS AK 53 G24 3000 x 2400 mm CS AK 54 G15 CS AK 54 G24 3000 x 3000 mm CS AK 55 G15 CS AK 55 G24 *Ceiling tiles are NOT included in the kit. All measurements in millimetres. All sizes are nominal.! RECOMMENDATIONS Axiom KE Canopies should always be installed in accordance with all applicable building codes and regulations. Axiom KE Canopies should only be installed on a horizontal plane. They are not approved for exterior installations. Axiom KE Canopies should always be installed by a minimum of 2 people. Read the installation instructions included in the carton carefully before starting the installation. Make sure the installation is clean and safe. Any additional weights (such as luminaires...) must be independently suspended from the soffit. Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing. 28 www.armstrong.eu

System Drawing The 1800 mm x 3000 mm module is used as an example only. An installation instruction guide is available. Please contact our Armstrong Technical Sales for further details. AXIOM KE CANOPY Design Options 4 Universal T bar connector clips 8 XL 2 connector clips 6 Aircraft cables & Gripple connectors 6 Universal T bar connector clips 16 Axiom universal splice plates 6 Channel brackets 6 T bar hangers 4 Mitre Corners 8 Corner splice connectors 12 Cross Tees 600 mm XL 2 (24 mm or 15 mm) 4 Axiom profiles cut to size 2 Main Runners cut to size (24 mm or 15 mm) 3 C channels cut to size OPTION 2 Quick hanger* OPTION 1 Aircraft cable & Gripple connectors OPTION 3 6 mm Threaded rod* * not included in the kit 29

Design Options AXIOM CIRCLE & CURVED Axiom Curved and Circle Canopies is an aesthetic perimeter trim system designed to create ceiling clouds in conjunction with full size tiles. Made from standard ceiling panels and ready to assemble Axiom components, Curved and Circle Canopies will define and individualise every space. Axiom Circle & Curved Components Item Nr. Description 62 42 06 G Axiom Circle and Curved Profile C3000 G Primary C Channel 30 40 33 A Prelude Peakform Main Runner T15 or 31 40 32 A Prelude Peakform Main Runner T24 30 20 33 B Prelude XL 2 Cross Tee 600 mm T15 or Tegular / MicroLook 31 20 21 A Prelude XL 2 Cross Tee 600 mm T24 AWDN 21 H T bar hanger 1.8m Ø Canopy 1.8m x 2.4m Canopy 1.8m x 3m Canopy A 361 G Splice connector A 339 H Axiom universal T bar connector clip for cut tees with screws A 156 G Perimeter fillin for 15 mm grid 2.4m Ø Canopy 2.4m x 2.4m Canopy 2.4m x 3m Canopy A 246 G Perimeter fillin for 24 mm grid A 348 G Channel bracket 3m x 3m Canopy CA 97 G Clamp for C Channel Axiom Circle & Curved Kits * Module Grid system 15 mm XL 2 Grid system 24 mm XL 2 Item Nr. Item Nr. Circle 1800 CS ACI 33 G15 CS ACI 33 G24 Circle 2400 CS ACI 44 G15 CS ACI 44 G24 Curved 2400 x 1800 CS ACU 43 G15 CS ACU 43 G24 Curved 2400 x 2400 CS ACU 44 G15 CS ACU 44 G24 Curved 3000 x 1800 CS ACU 53 G15 CS ACU 53 G24 Curved 3000 x 2400 CS ACU 54 G15 CS ACU 54 G24 Curved 3000 x 3000 CS ACU 55 G15 CS ACU 55 G24 *Ceiling tiles are NOT included in the kit.! RECOMMENDATIONS Axiom Circle & Curved Canopies should always be installed in accordance with all applicable building codes and regulations. Axiom Circle & Curved Canopies should only be installed on a horizontal plane. They are not approved for exterior installations. Axiom Circle & Curved Canopies should always be installed by a minimum of 2 people. Read the installation instructions included in the carton carefully before starting the installation. Make sure the installation is clean and safe. Any additional weights (such as luminaires...) must be independently suspended from the soffit. Aircraft cables are included as a standard in the kit but if you require more lateral restraint, we would recommend the use of 6 mm threaded rod or provide diagonal bracing. All measurements in millimetres. All sizes are nominal. 30 www.armstrong.eu

System Drawing The 1.8 x 2.4 m module is used as an example only. An installation instruction guide is available. Please contact our Armstrong Technical Sales for further details. AXIOM CIRCLE & CURVED Design Options 10 Universal T bar connector clips 6 Aircraft cables & Gripple connectors 6 Universal T bar connector clips Splice connector 6 Channel brackets 6 T bar hangers Axiom Profiles cut to size 2 Main Runners cut to size (24 mm or 15 mm) 12 Cross Tees 600 mm XL2 (24 mm or 15 mm) 3 C Channels cut to size OPTION 2 Quick hanger* OPTION 1 Aircraft cable & Gripple connectors OPTION 3 6 mm Threaded rod* * not included in the kit 31

Design Options SILHOUETTE 15 XL 2 Exposed 15 mm grid system (nominal). Silhouette 15 XL 2 is a suspension system designed to create a crisp, clean look in conjunction with MicroLook tiles to provide an enhanced aesthetic. Main Runners Silhouette 15 (bypass connection) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg with 6 mm reveal 80 40 42 G (1) 3600 44 20 72,00 24,50 36 80 39 43 G (1) 3125 44 20 62,50 25,40 25 80 44 42 G (1) 2700 44 20 54,00 18,40 30 with 3 mm reveal 81 40 42 WRG (2) 3600 44 20 72,00 24,50 36 Peakform Cross Tees Silhouette 15 XL 2 (stab system) with 6 mm reveal 80 30 42 G (1) 1200 44 60 72,00 24,50 35 80 31 43 G (1) 1250 44 60 75,00 23,50 35 80 33 42 G (1) 1350 44 30 40,50 13,80 50 80 32 42 G (1) 1000 44 60 60,00 20,40 24 80 20 42 G (1) 600 44 60 36,00 12,70 70 80 21 43 G (1) 625 44 30 37,50 16,00 70 80 23 42 G (1) 675 44 60 40,50 14,30 70 80 22 42 G (1) 500 44 60 30,00 10,60 70 80 24 42 G (1) 300 44 120 36,00 34,00 70 with 3 mm reveal 81 30 42 WRG (2) 1200 44 60 72,00 24,50 35 81 20 42 WRG (2) 600 44 60 36,00 12,70 70 Section Drawings Main Runners Silhouette 15 Length 3600 300 600 3 x 600 600 300 3500 250 500 4 x 500 500 250 3125 312,5 625 2 x 625 625 312,5 2700 337,5 675 675 675 337,5 Cross Tee Silhouette 15 XL 2 Length 1350 675 675 1250 625 625 1200 600 600 1000 500 500 Cross Tee Silhouette 15 XL 2 675 / 625 / 600 / 500 / 300 All products standard in Global White unless indicated by index (2). Other standard colours available for item numbers with index (1). See details below. (1) Silhouette with 6 mm reveal is available in white, black (BK) or white with black reveal (BI). (2) WR = White RAL 9010 (WR) All measurements in millimetres. All sizes are nominal. 32 www.armstrong.eu

Silhouette 15 XL 2 Premitred intersections Choice of either 6 or 3 mm reveal dimension Silhouette 15 XL 2 with 3 mm reveal is supplied as standard in RAL 9010 white to compliment Armstrong metal tiles Perimeter Solutions SILHOUETTE 15 XL 2 Design Options Section Cross Tee trimmed to wall angle View of mitred intersection from beneath Section 8 4 24 Cross Tee trimmed to shadowline T 1508 HB at perimeter MCC4 G Mitre closure clip for 6 mm reveal Axiom Profiles (50, 100, 112, 150 and 200 mm heights available) Silhouette 15 XL 2 system A 339 G Axiom universal T bar connector clip Grid Load Capacity Silhouette 15 XL 2 System The following table gives the maximum permitted hanger distance (mm) along the Silhouette Main Runner (80 40 42 G) for the tile weights and Main Runner spacings noted. Tile weight 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 Main Runner spacing 1200 mm 1200 mm XL 2 Cross Tee 80 30 42 G 1800 1700 1650 1600 1500 1450 1400 1300 1200 1100 950 Hanger spacing Main Runner spacing 600 mm 600 mm XL 2 Cross Tee 80 20 42 G 2100 2100 2050 2000 1900 1850 1800 1700 1600 1550 1350 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 33

Design Options INTERLUDE 15 XL 2 Exposed 15 mm grid system (nominal). Interlude 15 XL 2 is a suspension system developed for creative ceiling solutions, and quick and easy installation. Main Runner Interlude 15 (bypass connection) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg TZ 61 40 42 3600 44 20 72,00 23,60 36 Cross Tees Interlude 15 XL 2 (stab system) Cross Tees slotted 61 30 42 G 1200 44 60 72,00 30,30 42 Cross Tees unslotted 61 20 42 G 600 44 60 36,00 15,00 84 TZ 61 24 42 300 44 120 36,00 15,00 84 Section Drawings Main Runner Interlude 15 Length 3600 75 150 22 x 150 75 Cross Tee Interlude 15 XL 2 Length 1200 600 600 Cross Tee Interlude 15 XL 2 600 / 300 Product available as standard in Global White. All measurements in millimetres. All sizes are nominal. 34 www.armstrong.eu

Interlude 15 XL 2 The stepped flange profile provides a unique double reveal visual Unmitred intersections allow for Cross Tee installation at any Main Runner slot position Perimeter Solutions INTERLUDE 15 XL 2 Design Options Interlude 15 XL 2 can be easily field cut with snips in 3 simple steps: Section Cross Tee trimmed to wall angle 1. Cut down through bulb and web Section Cross Tee trimmed to shadowline T 1508 HB 2. Snip flanges Partition Head Fixing 3. Bend away from bulb to snap off centre rail UPC AG Universal partition clip attaches to grid to provide fixing for partition head track: reversible for 15 mm or 24 mm grid systems Grid Load Capacities Interlude 15 XL 2 system The following table gives the maximum permitted hanger distance (mm) along the Interlude Main Runner (TZ 61 40 42) for the tile weights and Main Runner spacings noted. Tile weight 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 Main Runner spacing 1200 mm 1200 mm XL 2 Cross Tee 61 30 42 G 1950 1850 1750 1750 1650 1600 1550 1450 1350 1250 1100 Hanger spacing Main Runner spacing 600 mm 600 mm XL 2 Cross Tee 61 20 42 G 2100 2100 2100 2100 2050 2000 1950 1850 1750 1650 1550 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 20 21. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 35

General Applications PRELUDE 15 Exposed 15 mm grid system (nominal). Universal Main Runners Prelude 15 Peakform and Superlock Clip (bulbtobulb connection) Cross Tees Prelude 15 XL 2 (stab system, override) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 30 40 33 A (1) 3600 43 20 72,00 22,50 32 30 41 33 A (1) 3750 43 20 75,00 23,20 32 30 43 33 A 3375 43 20 67,50 22,50 32 Cross Tees slotted 30 30 33 B (1) 1200 38 60 72,00 20,70 72 30 31 33 A 1250 38 60 75,00 21,50 72 30 32 33 (2) 1000 38 60 60,00 17,20 72 Cross Tees unslotted 30 20 33 B (1) 600 38 60 36,00 10,30 144 30 21 33 A 625 38 60 37,50 10,70 144 30 22 33 (2) 500 38 60 30,00 8,60 144 Cross Tees Prelude 15 TL (hook system, butt cut) Cross Tees slotted 10 34 33 B 1800 38 30 54,00 15,20 20 10 36 33 A 1500 38 30 45,00 14,00 20 10 33 33 1350 38 60 81,00 26,00 72 10 31 33 B (1) 1250 38 60 75,00 21,60 72 10 30 33 A (1) 1200 38 60 72,00 20,70 72 Cross Tees unslotted 10 23 33 675 38 60 40,50 13,00 144 10 21 33 B (1) 625 38 60 37,50 10,70 144 10 20 33 A (1) 600 38 60 36,00 10,30 144 10 25 33 312,50 38 120 37,50 12,50 144 10 24 33 A 300 38 120 36,00 11,50 144 10 12 32 150 38 60 9,00 2,84 144 Section Drawings Universal Main Runners Prelude 15 Length 3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 50 3375 337,5 675 2 x 675 675 337,5 Cross Tee Prelude 15 XL 2 Cross Tee Prelude 15 TL Length 1250 312,5 2 x 312,5 312,5 1200 300 2 x 300 300 1000 250 2 x 250 250 Cross Tee Prelude 15 XL 2 Length 1800 300 4 x 300 300 1500 300 3 x 300 300 1350 337,5 2 x 337,5 337,5 1250 312,5 2 x 312,5 312,5 1200 300 2 x 300 300 Cross Tee Prelude 15 TL 625 / 600 / 500 675 / 625 / 600 / 312,5 / 300 /150 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1)Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in RAL 9010 (WR). Cross tee alignment is achieved by locating the tees to the righthand side of the adjoining section. All measurements in millimetres. All sizes are nominal. 36 www.armstrong.eu

System Drawing (module 600 x 600 mm) Standard layin installation of 15 mm exposed suspension system for MicroLook tiles and specific Board tiles. PRELUDE 15 General Applications *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m 2 (no waste included) 6 1 2 3 4 7 Tile Main Runner Hanger centres Main Runner Cross Tee Cross Tee Hanger Universal centres 1200 mm 600 mm retaining clip 600 x 600 mm 2,78 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 1,67 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 1200 x 600 mm 1,39 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 5 Perimeter trim approx. 0,70 lm/m The chart is for general guidance only. 2 Grid Load Capacities Prelude 15 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (30 40 33 A) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1200 mm 1200 mm TLCross Tee 10 30 33 A Main Runner spacing 600 mm 600 mm TL Cross Tee 10 20 33 A Main Runner spacing 1200 mm 1200 mm XL 2 Cross Tee 30 30 33 B Main Runner spacing 600 mm 600 mm XL 2 Cross Tee 30 20 33 B 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 1900 1800 1750 1650 1550 1550 1500 1400 1300 1150 1050 2100 2100 2100 2050 2000 1950 1900 1800 1700 1600 1500 1900 1800 1750 1650 1550 1550 1500 1400 1300 1150 1050 2100 2100 2100 2050 2000 1950 1900 1800 1700 1600 1500 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. 37

General Applications PRELUDE 24 XL 2 Exposed 24 mm grid system (nominal). Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulbtobulb connection) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 31 40 32 A (1) 3600 43 20 72,00 21,00 30 31 41 33 B (1) 3750 43 20 75,00 21,90 30 31 43 33 A 3375 43 20 67,50 20,00 30 31 42 32 3000 43 20 60,00 17,50 30 Cross Tees Prelude 24 XL 2 (stab system, override) Cross Tees slotted 31 33 31 1350 38 60 81,00 17,20 20 31 31 51 B (1) 1250 38 60 75,00 18,90 72 31 30 51 B (1) 1200 38 60 72,00 18,20 72 31 32 31 (2) 1000 38 60 60,00 15,10 42 31 34 31 A 1800 38 30 54,00 17,00 20 Cross Tees unslotted 31 16 32 750 38 60 45,00 14,70 72 31 25 32 312,50 38 60 18,75 4,60 144 31 24 32 300 38 60 18,00 4,60 144 31 23 21 675 30 60 40,50 7,70 144 31 21 23 A (1) 625 30 60 37,50 8,60 144 31 20 21 A (1) 600 30 60 36,00 8,20 144 31 22 21 (2) 500 30 60 30,00 6,80 84 Section Drawings Universal Main Runners Prelude 24 Length 3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 50 3375 337,5 675 2 x 675 675 337,5 3000 50 100 27 x 100 100 50 Cross Tee Prelude 24 XL 2 Length 1800 300 4 x 300 300 1350 337,5 2 x 337,5 337,5 1250 312,5 2 x 312,5 312,5 1200 300 2 x 300 300 1000 250 2 x 250 250 Cross Tee Prelude 24 XL 2 750 / 675 / 625 / 600 / 500 / 312,50 / 300 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in RAL 9010 (WR). Cross tee alignment is achieved by locating the tees to the righthand side of the adjoining section. All measurements in millimetres. All sizes are nominal. 38 www.armstrong.eu

System Drawing (module 1200 x 600 mm) Standard layin installation of 24 mm exposed suspension system using Board, Tegular or Vector tiles. * * PRELUDE 24 XL 2 General Applications *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m 2 (no waste included) 6 Tile Main Runner Hangers 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal centres centres 1200 mm 600 mm retaining clip 1200 x 600 mm 1,39 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 600 x 600 mm 2,78 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 1,67 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 5 Perimeter trim approx. 0,70 lm/m 2 The chart is for general guidance only. Grid Load Capacities Prelude 24 XL 2 System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 Main Runner spacing 1800 mm 1800 mm XL 2 Cross Tee 31 34 31 A 1650 1600 1500 1450 1350 1350 1250 Main Runner spacing 1200 mm 1200 mm XL 2 Cross Tee 31 30 51 B 1900 1800 1750 1700 1600 1550 1500 1450 1300 1200 1050 Main Runner spacing 600 mm 60 mm XL 2 Cross Tee 31 20 21 A 2100 2100 2100 2100 2000 1950 1900 1800 1700 1600 1500 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 39

General Applications PRELUDE 24 TLX Exposed 24mm grid system (nominal). Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulbtobulb connection) Cross Tees Prelude 24 TLX (Hook system, butt cut) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg 31 40 32 A (1) 3600 43 20 72,00 21,00 30 31 41 33 B (1) 3750 43 20 75,00 21,90 30 31 43 33 A 3375 43 20 67,50 20,00 30 31 42 32 3000 43 20 60,00 17,50 30 Cross Tees slotted 13 31 31 (1) 1250 38 60 75,00 18,90 72 13 30 31 (1) (2) 1200 38 60 72,00 18,10 72 13 60 31 600 38 60 36,00 9,10 144 13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 20 13 33 31 1350 38 60 81,00 19,60 20 13 32 32 1000 38 60 60,00 19,40 72 Cross Tees unslotted 13 18 31 900 38 60 54,00 13,60 72 13 16 31 750 38 60 45,00 11,40 72 13 21 31 (1) 625 38 60 37,50 9,50 144 13 20 31 (1) (2) 600 38 60 36,00 9,10 144 13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80 Section Drawings Universal Main Runners Prelude 24 Length 3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 50 3375 337,5 675 2 x 675 675 337,5 3000 50 100 27 x 100 100 50 Cross Tee Prelude 24 TLX Cross Tee Prelude 24 TLX 900 / 750 / 675 / 625 / 600 / 500 Length 1875 312,5 4 x 312,5 312,5 1800 300 4 x 300 300 1724 262 4 x 300 262 1500 150 350 / 2 x 250 / 350 150 1350 337,5 2 x 337,5 337,5 1250 312,5 2 x 312,5 312,5 1200 300 2 x 300 300 1000 250 2 x 250 250 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE) and White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR) and Beige (BJ). Cross tee alignment is achieved by locating the tees to the righthand side of the adjoining section. 40 www.armstrong.eu

System Drawing (module 1200 x 600 mm) Standard layin installation of 24 mm exposed suspension system using Board, Tegular or Vector edge tiles. * PRELUDE 24 TLX General Applications *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m 2 (no waste included) 6 Tile Main Runner Hanger 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal centres centres 1200 mm 600 mm Retaining Clip 1200 x 600 mm 1,39 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 600 x 600 mm 2,78 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 1,67 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 5 Perimeter Trim approx. 0,70 lm/m 2 The chart is for general guidance only. Grid Load Capacities Prelude 24 TLX System The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (31 40 32 A) for the tile weights and Main Runner spacings noted. Hanger spacing Tile weight Main Runner spacing 1800 mm 1800 mm TLXCross Tee 13 34 32 Main Runner spacing 1200 mm 1200 mm TLXCross Tee 13 30 31 Main Runner spacing 600 mm 600 mm TLX Cross Tee 13 20 31 2,5 kg/m 2 1650 1900 2100 3,0 kg/m 2 1600 1800 2100 3,5 kg/m 2 1500 1750 2100 4,0 kg/m 2 1450 1700 2100 5,0 kg/m 2 1350 1600 2000 5,5 kg/m 2 1350 1550 1950 6,0 kg/m 2 1250 1500 1900 7,0 kg/m 2 1450 1800 8,5 kg/m 2 1300 1700 10,5 kg/m 2 1200 1600 13,0 kg/m 2 1050 1500 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 41

General Applications PRELUDE SIXTY 2 Exposed 24 mm grid system (nominal). Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL 2 and TLX Cross Tees. For corridor applications please see on page 5051. Universal Main Runner Prelude Sixty 2 Double Peakform with Superlock Clip (bulb to bulb connection) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg 40 40 93 G (1) 3600 62 12 43,20 21,90 36 40 41 93 G (1) 3750 62 12 45,00 22,80 36 40 43 93 G (1) 3375 62 12 40,50 20,60 36 Universal Main Runner Prelude Sixty 2 Length 3750 156,25 11 x 312,5 156,25 3600 150 11 x 300 150 3375 168,75 9 x 337,5 168,75 Cross Tees Prelude 24 TLX (hook system, butt cut) Cross Tees slotted 13 31 31 (1) 1250 38 60 75,00 18,90 72 13 30 31 (1) (2) 1200 38 60 72,00 18,10 72 13 60 31 600 38 60 36,00 9,10 144 13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 20 13 33 31 1350 38 60 81,00 19,60 20 13 32 32 1000 38 60 60,00 19,40 72 Cross Tees unslotted 13 18 31 900 38 60 54,00 13,60 72 13 16 31 750 38 60 45,00 11,40 72 13 21 31 (1) 625 38 60 37,50 9,50 144 13 20 31 (1) (2) 600 38 60 36,00 9,10 144 13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80 Cross Tees Prelude 24 XL 2 (stab system, override) Cross Tees slotted 31 33 31 1350 38 60 81,00 17,20 20 31 31 51 B (1) 1250 38 60 75,00 18,90 72 31 30 51 B (1) 1200 38 60 72,00 18,20 72 31 32 31 (3) 1000 38 60 60,00 15,10 42 31 34 31 A 1800 38 30 54,00 17,00 20 Cross Tees unslotted 31 16 32 750 38 60 45,00 14,70 72 31 25 32 312,50 38 60 18,75 4,60 144 31 24 32 300 38 60 18,00 4,60 144 31 23 21 675 30 60 40,50 7,70 144 31 21 23 A (1) 625 30 60 37,50 8,60 144 31 20 21 A (1) 600 30 60 36,00 8,20 144 31 22 21 (3) 500 30 60 30,00 6,80 84 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR), Beige (BJ). (3) Also available in RAL 9010 (WR). All measurements in millimetres. All sizes are nominal. 42 www.armstrong.eu

System Drawing (module 1800 x 300 mm) Standard layin installation of 24 mm exposed suspension system using Board or Tegular edge planks. PRELUDE SIXTY 2 General Applications Quantities required per 1m 2 (no waste included) 3 Tile Main Runner centres 1 Main Runner 2 Cross Tee 1800 mm 2 Cross Tee 1200 mm 2 Cross Tee 600 mm 1800 x 300 mm 1800 mm 0,56 lm 3,34 lm 1800 mm 0,56 lm 1,67 lm 1,12 lm 600 x 600 mm 1200 mm 0,84 lm 1,67 lm 0,84 lm 600 mm 1,67 lm 1,67 lm 1200 x 600 mm 1200 mm 600 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm The chart is for general guidance only. Accessories Item Nr. Description Dimensions Content/Carton Weight/Carton Length (mm) Height (mm) pcs kg A 401 G Top Connector Clip accessory for Prelude Sixty 2 (Included in the carton) A WDN 23 G Double bent tee bar hanger 57 36 100 2,30 Grid Load Capacities Prelude Sixty 2 System Tile weight 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 Main Runner spacing 1800 mm 1800 mm Cross Tees 31 34 31 A/13 34 32 2300 2200 2150 2100 2000 1900 1850 Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. The following table gives the maximum permitted hanger distance (mm) along the double Peakform Main Runner (40 40 93 G) for the tile weights and Main Runner spacings noted. Hanger spacing Main Runner spacing 1200 mm 1200 mm Cross Tees 31 30 51 B/13 30 31 2400 2400 2350 2300 2200 2150 2100 2050 1900 1700 1550 Main Runner spacing 600 mm 600 mm Cross Tees 31 20 21 A/13 20 31 2400 2400 2400 2400 2400 2400 2400 2400 2300 2200 2100 43 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021.

General Applications PRELUDE 35 XL 2 Exposed 35 mm grid system (nominal). For use in large shed type buildings including retail outlets, industrial manufacturing and meeting halls, etc... Main Runners Peakform Prelude 35 XL 2 (bulbtobulb connection) 43 mm Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg White capping 24 40 42 3600 43 16 57,60 22,20 20 Galvanised capping 24 40 42 UP 3600 43 16 57,60 23,50 20 35 mm Black capping 24 40 42 BK 3600 43 16 57,60 22,20 20 Cross Tees Peakform Prelude 35 XL 2 (stab system, override) 43 mm White capping 24 06 42 1990 43 16 31,80 12,30 20 24 36 42 1500 43 32 48,00 16,60 20 24 30 42 1200 43 36 43,20 14,90 60 24 20 42 600 43 36 21,60 7,50 120 35 mm 35 mm 43 mm Galvanised capping 24 06 42 UP 1990 43 16 31,80 13,00 20 24 36 42 UP 1500 43 32 48,00 17,70 20 24 30 42 UP 1200 43 36 43,20 15,90 60 24 20 42 UP 600 43 36 21,60 8,00 120 Black capping 24 06 42 BK 1990 43 16 31,80 12,30 20 24 36 42 BK 1500 43 32 48,00 16,60 20 24 30 42 BK 1200 43 36 43,20 14,90 60 24 20 42 BK 600 43 36 21,60 7,50 120 Perimeter Trim Item Nr. Description Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 30 T 3024 H Perimeter angle, White painted 3000 24 40 120,00 28,50 50 30 30 T 3030 H* Perimeter angle, White painted 3000 30 30 90,00 25,00 40 * Also available in Galvanised (UP) and Black (BK) Please add the corresponding suffix to the item number when placing the order. Section Drawings Main Runners Prelude 35 Length 3600 50 100 33 x 100 100 50 Cross Tee Prelude 35 XL 2 Length 1200 600 600 Cross Tee Prelude 35 XL 2 1990 / 1500 / 600 Cross Tee alignment is achieved by locating the tees to the righthand side of the adjoining section. All dimensions in millimetres. All sizes are nominal. 44 www.armstrong.eu

Key Attributes Peakform Patented universal Main Runner and Cross Tee design increase strength and stability for improved performance and makes the grid easier to cut Rotary stitched Main Runner and Cross Tees for additional torsional strength and extra stability during installation Physical Data Material Doubleweb galvanised steel Surface Finish Baked polyester paint Product Family Exposed tee system Main Runner / Cross Tee Interface Joggled ends PRELUDE 35 XL 2 End Detail Main Runner : with Superlock clip, by pass coupling, single stitching Cross Tees : stakedon stab clip, double stitching General Applications Colour Available in White, Galvanised and Black. Grid Load Capacities Prelude 35 XL 2 System The following table gives the maximum permitted hanger distance (L) along the Main Runner (24 40 42). Hanger spacing Tile weight 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 4,5 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 6,5 kg/m 2 7,0 kg/m 2 8,0 kg/m 2 9,0 kg/m 2 10,0 kg/m 2 12,0 kg/m 2 14,0 kg/m 2 Main Runner spacing 1990 mm (x 1000 mm) 1990 mm XL 2 Cross Tee 24 06 42 1700 1600 1550 Main Runner spacing 1500 mm (x 1000 mm) 1500 mm XL 2 Cross Tee 24 36 42 1900 1800 1700 1650 1600 1550 1500 1400 1350 1300 1250 Main Runner spacing 1200 mm (x 600 mm) 1200 mm XL 2 Cross Tee 24 30 42 1900 1850 1750 1700 1650 1600 1550 1500 1500 1450 1400 1300 1250 1150 1050 Main Runner spacing 600 mm (x 600 mm) 600 mm XL 2 Cross Tee 24 20 42 2000 2000 2000 2000 2000 2000 1950 1900 1900 1850 1750 1700 1650 1550 1450 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 45

General Applications BANDRASTER Bandraster is a suspension system available in a wide range of widths, compatible with Prelude 24 TLX/XL 2 Cross Tees. Bandraster Systems 12mm 150 / 125 / 100 / 75 / 50mm 36mm Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) Height (mm) pcs lm kg Slotted at 312,50 mm (1) 36 2100 B 3750 100 8 30,00 32,60 16 Slotted at 100 mm (1) 36 3050 3600 50 8 28,80 24,00 28 36 3075 3600 75 8 28,80 27,70 20 36 3100* 3600 100 8 28,80 31,40 16 36 3125 3600 125 8 28,80 38,30 12 36 3150 3600 150 4 14,40 21,20 20 Unslotted (2) 36 0050 A 3600 50 8 28,80 24,00 28 36 0075 A* 3600 75 8 28,80 27,70 20 36 0100 A 3600 100 8 28,80 31,40 16 36 0125 A 3600 125 8 28,80 38,30 12 36 0150 3600 150 4 14,40 21,20 20 (1) Is compatible with all plank edge details whether cross tees are required or not. (2) Is compatible with only with plank edge details when no visible cross tees span between bandraster sections. Bandraster Accessories Item Nr. Description Dimension Content / Carton Weight / Carton height (mm) pcs kg A 36 0501 Strip / rod connector 50 50 1,20 A 36 0751 75 50 1,50 A 36 1001 100 50 1,80 A 36 0502 G Nonius hanger 50 100 5,80 A 36 0752 G 75 100 8,10 A 36 1002 G 100 100 11,00 A 36 1252 G 125 100 12,50 A 36 1502 G 150 100 15,00 A 36 0503 G Splice 50 100 8,00 A 36 0753 G 75 100 8,30 A 36 1003 G 100 100 14,00 A 36 1253 G 125 100 17,00 A 36 1503 G 150 100 19,50 A 36 0504 G Cross connector 50 100 5,80 A 36 0754 G 75 100 8,10 A 36 1004 G 100 100 11,00 A 36 1254 G 125 100 12,50 A 36 1504 G 150 50 7,50 A 36 0505 G Wall connector 50 100 5,80 A 36 0755 G 75 100 8,10 A 36 1005 G 100 100 11,00 A 36 1255 G 125 100 12,50 A 36 1505 G 150 50 7,50 A 36 0506 G Crossing element 50 48 7,70 A 36 0756 G 75 30 5,70 A 36 1006 G 100 32 7,40 Product available as standard in Global White. *Also available in RAL 9010 (WR) All measurements in millimetres. All sizes are nominal. 46 www.armstrong.eu

System Drawing Slotted Bandraster is compatible either with Prelude 24 XL 2 or Prelude 24 TLX Cross Tees On special request: Prelude 15 TL can be made compatible for installation with slotted Bandraster; Special spaced slotting; minimum slot spacing is 50 mm; Maximum length of Bandraster is 5000 mm Upper part of Nonius BANDRASTER General Applications Pin to connect bottom and upper part of Nonius A 10229 G (It is recommended to use 2 pins to connect bottom & upper part of Nonius) Splice Nonius hanger Strip / rod connector Cross connector Crossing element Wall connector Threaded rod A 1829 G Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 47

General Applications SYSTEM Z Semiconcealed and concealed systems. Provides specialist solution for corridors giving a monolithic visual. Can also be used for room situations in conjunction with Prelude 24 and Bandraster grid. SemiConcealed Compatible with SL2 and K2C2 Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg CZ 41494 H Deep Z 32 mm 1500 20 30,00 9,40 CZ 41794 H Deep Z 32 mm 1800 20 36,00 11,30 CZ 41795 H Deep Z 70 mm 2500 10 25,00 13,40 CA 5740 G Double height Z 4000 10 40,00 24,00 CA 5733 A Spacer bar 600/625 50 31,20 7,00 CA 5734 Spacer bar 1200/1250 50 62,50 14,00 SemiConcealed CZ 3600 H Z section 3600 20 72,00 22,70 CZ 3600 H CA 21 G Z connector 150 500 10,00 CA 21 G CC 4000 G CA 120 G CC 4000 G Channel 13 x 38 mm 4000 20 80,00 26,50 C 3000 G Channel 19 x 38 mm 4000 8 32,00 23,80 CA 120 G Preformed channel clip 100 0,50 All measurements in millimetres. All sizes are nominal. 48 www.armstrong.eu

SemiConcealed (continued) CC 4000 G SYSTEM Z Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) pcs lm kg CA 97 G Clamp for Cchannel 30 100 1,70 CT 600 G Noggin tee 600 100 60 8,50 General Applications CA 5730 G Antibreather spline 295 200 3,80 System Drawing Semiconcealed SL2/K2C2 Corridor installation SL2 K2C2 Quantities required per 1m 2 (no waste included) 3 Plank size Supporting sections at Z Profile CZ 41494 H 1 Z Profile CZ 41794 H Z Profile CZ 41795 H 1500 x 300 / 312,5 mm 1800 x 300 / 312,5 mm 2500 x 300 / 312,5 mm 300 / 312,5 mm 300 / 312,5 mm 300 / 312,5 mm 3,33 / 3,20 lm 3,33/3,20 lm 3,33 / 3,20 lm 2 Perimeter trim according to circumference of room Perimeter angles should be of thicker material when corridor wider than 1,80 m. The chart is for general guidance only. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 49

Corridor PRELUDE SIXTY 2 Exposed 24 mm grid system (nominal). Double Peakform Main Runner section requiring less suspension points and compatible with Prelude 24 XL 2 and TLX Cross Tees. Universal Main Runner Prelude Sixty 2 Double Peakform The Prelude Sixty 2 system is designed for use in corridor applications, with or without Cross Tees, and where spans do not exceed 3750 mm. For a wider configuration, the Main Runner is compatible with the Prelude 24 TLX and XL 2 Cross Tees. Special length and modulation made to order, with and without slots, please contact your Armstrong Technical Sales. Universal Main Runner Prelude Sixty 2 Length min. 600 mm max. 3750 mm min. 150 min. 300 x number of required slots min. 150 Cross Tees Prelude 24 TLX (hook system, butt cut) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet Length (mm) Height (mm) pcs lm kg Cross Tees slotted 13 31 31 (1) 1250 38 60 75,00 18,90 72 13 30 31 (1) (2) 1200 38 60 72,00 18,10 72 13 60 31 600 38 60 36,00 9,10 144 13 10 32 1875 38 30 56,20 17,80 20 13 34 32 1800 38 30 54,00 17,10 20 13 50 32 1724 38 30 51,70 16,50 20 13 36 32 1500 38 30 45,00 14,50 20 13 33 31 1350 38 60 81,00 19,60 20 13 32 32 1000 38 60 60,00 19,40 72 Cross Tees unslotted 13 18 31 900 38 60 54,00 13,60 72 13 16 31 750 38 60 45,00 11,40 72 13 21 31 (1) 625 38 60 37,50 9,50 144 13 20 31 (1) (2) 600 38 60 36,00 9,10 144 13 23 31 675 38 60 40,50 8,70 144 13 22 32 500 38 60 30,00 9,70 80 Cross Tees Prelude 24 XL 2 (stab system, override) Cross Tees slotted 31 33 31 1350 38 60 81,00 17,20 20 31 31 51 B (1) 1250 38 60 75,00 18,90 72 31 30 51 B (1) 1200 38 60 72,00 18,20 72 31 32 31 (3) 1000 38 60 60,00 15,10 42 31 34 31 A 1800 38 30 54,00 17,00 20 Cross Tees unslotted 31 16 32 750 38 60 45,00 14,70 72 31 25 32 312,50 38 60 18,75 4,60 144 31 24 32 300 38 60 18,00 4,20 144 31 23 21 675 30 60 40,50 7,70 144 31 21 23 A (1) 625 30 60 37,50 8,60 144 31 20 21 A (1) 600 30 60 36,00 8,20 144 31 22 21 (3) 500 30 60 30,00 6,80 84 All products standard in Global White. Other standard colours available for item numbers with index (1) or (2). See details below. (1) Colours available : Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Brass (BS), Chrome (CE), White RAL 9010 (WR). (2) Also available in Black (NG), Brown (MR), Beige (BJ). (3) Also available in RAL 9010 (WR). All measurements in millimetres. All sizes are nominal. 50 www.armstrong.eu

Accessories PRELUDE SIXTY 2 Item Nr. Description Dimensions Content / Carton Weight / Carton Length (mm) Height (mm) pcs kg Corridor A WDN23 G Double bent tee bar hanger 57 36 100 2,30 System Drawing Double bent tee bar hanger Planks Perimeter trim Grid Load Capacities Span in mm Load capacities in kg/m 2 Spacing (mm) 1600 1700 1800 1900 2000 2100 2200 2300 2400 2500 2600 2700 2800 2900 3000 Prelude Sixty 2 300 37,2 32,8 29,1 25,9 23,2 20,9 18,9 17,2 15,6 14,3 13,1 11,8 10,0 8,5 7,1 Butt cut 600 18,6 16,4 14,5 13,0 11,6 10,5 9,5 8,6 7,8 7,1 6,5 5,9 5,0 4,2 3,5 1200 9,3 8,2 7,3 6,5 5,8 5,2 4,7 4,3 3,9 3,5 3,2 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. (1) Colours available: Carrara (CA), Platinum (PN), Black (BK), RAL 9006 (SG), Chrome (CE), White RAL 9010 (WR), Brass (BS). All measurements in millimetres. All sizes are nominal. Please contact our Armstrong Technical Sales for further details. 51

Specific Applications CLEAN ROOM GRID SYSTEM Exposed 24 mm grid system (nominal). A complete system solution: Aluminium construction for maximum corrosion resistance and nonmagnetic environments. Coextruded with a unique factory applied gasket for a better seal between tile and grid. System suitable for use in applications up to Class 4 performance as per Class ISO standard 146441. Main Runner Clean Room Grid System 24 Item Nr. Dimensions Content /Carton Weight/Carton Cartons/Pallet length (mm) height (mm) pcs lm kg EA 794044 3600 43 20 72,00 24,00 30 Cross Tees Clean Room Grid System 24 + Perimeter Trim EA 793044 1200 43 60 72,00 26,00 20 EA 792044 600 43 60 36,00 12,00 40 EA 7801 3660 24 30 109,80 20,00 25 Accessories CHDC Hold down clip suitable for nonmagnetic areas 18 12 16 A 426 Board access clip Section Drawings Main Runner Clean Room Grid 24 Length 3600 150 300 9 x 300 300 150 Cross Tee Clean Room Grid 24 Length 1200 600 300 300 300 300 300 300 All measurements in millimetres. All sizes are nominal. Please contact our Armstrong Technical Sales for further details. 52 www.armstrong.eu

Key Attributes Aluminium construction for maximum corrosion resistance and nonmagnetic environments Unique coextruded section aluminium based Unique, factory applied gasket for a better seal between tile and grid Staked on main runner splice for easy connections, integral hook cross tee end detail Hold down clips to ensure a good seal System suitable for use in applications up to Class 4 performance per ISO standard 146441 CLEAN ROOM GRID SYSTEM Physical Data Material CoExtruded Aluminium Gasketed Cross Tee/Main runner Interface CoExtruded Aluminium Clean Room Flush Fit Product family Exposed grid system End Detail Main Runner: Stakedon clip Cross Tee: Integral hook Specific Applications Clean Room Holddown clip (CHDC) Clean Room Main Runner Clean Room Cross Tee Board Tile Grid Load Capacities Clean Room Grid 24 mm The table gives the maximum permitted hanger distance (mm) along the Clean Room Grid Main Runner (EA 794044) for the tile weights and Main Runner spacings noted. Tile weight Main Runner spacing 1200 mm Main Runner spacing 600 mm 1200 mm Cross Tee 600 mm Cross Tee EA 793044 EA 792044 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 1850 1750 1700 1650 1550 1500 1450 1400 1300 1200 1050 Hanger spacing 2100 2100 2100 2050 1950 1900 1850 1800 1700 1600 1450 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. All measurements in millimetres. All sizes are nominal. Please contact our Armstrong Technical Sales for further details. 53

Specific Applications PRELUDE 24 CORROSIVE RESISTANT Exposed 24 mm grid system (nominal). Special paint finish and TLX steelbased composite clip for enhanced corrosion resistance. Corrosion resistance 700 hours salt spray test on grids according to EN ISO 9227 standards. Durability Class C (EN13964:2004 + A1:2006) Universal Main Runners 24 Corrosive Resistant Peakform and Superlock Clip (bulb to bulb connection) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 28 40 42 3600 43 20 72,00 21,00 30 28 41 42 3750 43 20 75,00 21,90 30 Cross Tees TLX 24 Corrosive Resistant (Hook system, butt cut) 14 30 32 1200 38 60 72,00 18,20 72 14 31 32 1250 38 60 75,00 18,90 72 14 20 32 600 38 60 36,00 9,10 144 14 21 32 625 38 60 37,50 9,50 144 Section Drawings Main Runner 24 Corrosive Resistant Length 3750 78,125 156,25 21 x 156,25 156,25 78,125 3600 50 100 33 x 100 100 50 Cross Tee TLX 24 Corrosive Resistant Cross Tee TLX 24 Corrosive Resistant Length 1200 300 300 300 300 1250 312,5 312,5 312,5 312,5 600/ 625 Perimeter Solution Item Nr. Description Dimensions Content / Carton Weight / Carton length (mm) height (mm) pcs Im kg T 1924 LB Corrosive resistant 3050 24 36 109,80 27,60 perimeter angle Accessories Corrosion resistance 700 hours salt spray test For loading data please see standard versions of these items on pages 6667. A WDNCR 20 H Bent tee bar hanger for threaded rod A CR1827 G Nut for threaded rod A CR827 G 1700 mm hanger with hook A CR12 G Butterfly A CR1829 G 1000mm Threaded rod dia. 6 mm A CR7890 G Universal retaining clip A CR11 G Small hook T 1924 LB Corrosive resistant suspension angle Availability of products may vary according to location. 54 www.armstrong.eu

System Drawing (module 1200 x 600 mm) Standard layin installation of 24 mm exposed suspension system using Board or Tegular edge tiles. PRELUDE 24 CORROSIVE RESISTANT Specific Applications *reduce to 450 if heavy tile / overlays are used or heavy service fittings are located near the perimeter. Quantities required per 1m 2 (no waste included) 6 Tile Main Runner Hanger 1 Main Runner 2 Cross Tee 3 Cross Tee 4 Hanger 7 Universal centres centres 1200 mm 600 mm Retaining Clip 1200 x 600 mm 1,39 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 600 x 600 mm 2,78 pcs 1200 mm 600 mm 1200 mm 1200 mm 0,84 lm 1,67 lm 1,67 lm 0,84 lm 1,67 lm 0,70 pcs 1,40 pcs 5,56 pcs 5,56 pcs 5 Perimeter Trim approx. 0,70 lm/m 2 The chart is for general guidance only. Grid Load Capacities Prelude 24 Corrosive resistant The following table gives the maximum permitted hanger distance (mm) along the Peakform Main Runner (28 40 42) for the tile weights and Main Runner spacings noted. Tile weight 2,5 kg/m 2 3,0 kg/m 2 3,5 kg/m 2 4,0 kg/m 2 5,0 kg/m 2 5,5 kg/m 2 6,0 kg/m 2 7,0 kg/m 2 8,5 kg/m 2 10,5 kg/m 2 13,0 kg/m 2 Main Runner spacing 1200 mm 1200 mm Cross Tee 14 30 32 1900 1800 1750 1700 1600 1550 1500 1450 1300 1200 1050 Hanger spacing Main Runner spacing 600 mm 600 mm Cross Tee 14 20 32 2100 2100 2100 2100 2000 1950 1900 1800 1700 1600 1500 1) Values in the above table conform to Class 1 as defined in EN 13964:2004+A1:2006 table 6. For other classes /deflection limits please contact your local Armstrong Technical Sales. 2) Values are determined from laboratory tests methods in accordance with EN 13964:2004+A1:2006 clause 5. 3) Values are applicable for 600 x 600 mm tiles assuming that the maximum deflection of the grid is L/500 but not greater than 4 mm (L = span). 4) No other applied loads such as luminaires, air diffusers, smoke detectors, sprinklers, hanging signs etc. are permitted. 5) No overlays such as mineral wool or fibre glass quilts, as may be required for enhanced acoustic, fire or thermal performance, are permitted unless their full weight is established and included, together with the weight of the tile, within the appropriate weight groups. 6) For grid loading data calculated to different criteria than Class 1 to EN13964:2004+A1:2006, see the grid loading technical section on pages 2021. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 55

Specific Applications SEISMIC Rx SYSTEM Exposed 24mm grid system (nominal). Independently tested approach using Prelude XL 2 grid to achieve ceiling installations that can withstand the forces associated with significant seismic activity or other severe events. Universal Main Runners Prelude 24 Peakform and Superlock Clip (bulbtobulb connection) Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg 31 40 32 A (1) 3600 43 20 72,00 21,00 30 31 41 33 B 3750 43 20 67,50 20,00 30 Cross Tees Prelude 24 XL 2 (stab system, override) Cross Tees slotted 31 30 51 B (1) 1200 38 60 72,00 18,20 72 31 31 51 B (1) 1250 38 60 75,00 18,90 72 Cross Tees unslotted 31 20 21 A (1) 600 30 60 36,00 8,20 144 31 21 23 A (1) 625 30 60 37,50 8,60 144 Accessories Item Nr. Description Dimensions Quantity / Carton Weight / Carton Cartons / length (mm) pcs kg Pallet T 3024 H Perimeter angle, 3000 40 28,50 50 painted BERC2 Main Runner End 50 200 9,00 36 Retaining Clip SJCG Seismic Joint Clip 200 7,00 36 XL2 Cross Tee (24mm) SJMR15 Seismic Joint Clip 100 11,00 60 Peakform Main Runner (24mm) ES 4 Expansion Sleeve (24mm) 100 100 1,00 170 Availability of products may vary according to location. 442 Vector Seismic Clip 100 1,63 (1) Standard Colours available : BK (Black), CA (Carrara), PN (Platinum), BS (Brass), CE (Chrome), SG (RAL9006), WR (RAL 9010). For special colour, discover our 180 RAL available. Please, contact your local Sales Contact. 56 www.armstrong.eu

System Drawing T 3024 H perimeter trim BERC2 on all (four) sides of room prevents ends of Cross Tees and Main Runners from spreading apart 20mm clearance on two adjacent sides and 10mm overlap of grid on the perimeter trim SEISMIC Rx SYSTEM Specific Applications Attached Wall Detail Attached Wall B A A A Tight Screw 200mm MAX B x Main Runner x Main Runner 30 mm B Unattached Wall Detail Unattached Wall B B x x 200mm MAX B x x B 30mm 20mm Optional Screw B x 600mm c/c x B B B x Unattached Wall Hanger Wire Note: some recommendations / guidelines require additional hangers on perimeter Cross Tees within 200mm of the perimeter. This is not a requirement of the Seismic Rx solution using the BERC2 clip, but may also be incorporated to provide additional system security in very high hazard areas e.g. emergency services control centre, where full functionality is planned post event. For more comprehensive information regarding seismic installations please refer to our brochure "INSTALLATION GUIDELINES FOR SEISMIC APPLICATIONS Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 57

Specific Applications LONGSPAN SYSTEM LongSpan Grids are designed to create a primary framework underneath beams or between walls, thereby allowing the suspended ceiling Main Runners to be installed with fewer suspension points. Primary Channels 54mm 70mm 85mm 120mm Item Nr. Dimensions Content / Carton Weight / Carton Cartons / Pallet length (mm) height (mm) pcs lm kg LP 546 G 5000 54 5 25,00 18,40 10 LP 706 G 5000 70 5 25,00 23,60 10 LP 856 G 5000 85 5 25,00 25,10 10 LP 120 G 6500 120 5 32,50 63,30 10 40mm 40mm 40mm 40mm Accessories Item Nr. Description Dimensions Content / Carton Weight / Carton height (mm) pcs kg A 4510 G Bent hanger for T profile 50 2,00 A 1820 G Beam flange clip 47 100 2,20 A 1821 G 47 100 3,20 h A B11067 G Special holding clamp* 54 100 3,10 A B11066 G 70 100 4,30 A B11065 G 85 100 4,60 A B11064 G 120 50 3,30 A M4538 G Wall connection 54 25 1,30 A M4536 G 70 25 1,70 A M4534 G 85 25 3,20 A M4529 G 120 25 5,90 A R4537 G Connector 54 25 1,90 A R4535 G 70 25 2,30 A R4533 G 85 25 4,20 A R4528 G 120 25 7,00 CC 4000 G CA 120 G CC 4000 G Channel 13 x 38 mm 38 20 26,50 CA 120 G Preformed channel clip** 100 0,50 *Both Bent hanger for T profile and special holding clamp only work with threaded rod A 1829 G+ Connection A1839 G + nut (A 1827 G) **Install one clip on each side of the Channel CC 4000 G All measurements in millimetres. All sizes are nominal. 58 www.armstrong.eu

System Drawing AM 45... Wall connector AR 45... Connector Steel beam LONGSPAN SYSTEM Specific Applications Threaded rod A 1829 G + Connection A 1839 G + Nut A 1827 G CA 120 G Preformed channel clip 1200 CC 4000 G Channel (tie bar) A 182... Beam flange clip Steel beam A 4510 G Bent hanger for T profile 1200 LP... Primary channel Note : Two wall connectors A M45... must be used by connection Two connectors A R45... must be used by connection Two preformed channel clips CA 120 G must be installed on the opposites sides of the Primary channel AB 11... Special holding clamp Grid Load Capacities (LongSpan System) Space 1200 mm 1 tie bar 2 tie bars 3 tie bars Spacing between suspensions (m) 1,25 1,50 1,75 2,00 2,25 2,50 2,75 3,00 3,25 3,50 3,75 4,00 4,25 4,50 4,75 5,00 5,50 5,75 6,00 6,50 Item Nr. LP 546 G kg/m 2 48 48 32 23 16 12 9 LP 706 G kg/m 2 48 34 25 19 14 11 9 7 6 LP 856 G kg/m 2 48 42 25 19 15 12 10 8 7 7 LP 120 G kg/m 2 48 30 24 20 17 14 12 10 9 8 6 Note: Uniformly distributed load kg/m 2. Load charges in kg/m 2 for deflection L/300. Availability of products may vary according to location. Please contact our Armstrong Technical Sales for further details. 59