Solar Combiner Solutions

Similar documents
Solar Combiner Solutions

Mipco Connections for Refrigerated Containers. No One Does It Like Mipco. The Mipco. Advantage. Reliability. Safety. Easy Installation & Service

Quik-Spec. Section Contents

Now - Up To 400A Mains!

AM-Tite Series Non-Metallic Plugs MSR Series Switched and Interlocked Receptacles

Quik-Spec Electrical Gear

Bussmann series Quik-Spec Coordination Panelboard

Solar circuit protection application guide. Complete and reliable solar circuit protection

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Residential Transition Box. Model RU-1. Specifications. Electrical

2016 Photovoltaic Solar System Plan Review List

NMC Combination Line Starters and Enclosures

Photovoltaic Solar Plan Review

Design Standard. Purpose: Design Standard:

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Non-Fused Load Break Switches FSSC, SX, SXDC, SC

A. Submit manufacturer's literature and technical data before starting work.

Solar Power Installation Application

2018 Consultant s Handbook Division 26 Electrical 2413 Switchboards

Steel Outlet Boxes 4 11 /16" Welded

Simplified Guide To Understanding Short-Circuit Current Rating FIND IT, FIX IT, FORGET IT

PV Vault Yielding safety quickly

Taxonomies, Classifications, and Categories CIRCUIT BREAKING, COMPRESSOR, CONVEYOR, MOTOR GENERATOR SET, POLARIZED, WELDER

Fused Coordination Panelboard

BRANCH CIRCUIT PROTECTION FUSED COORDINATION PANELBOARD

Understanding National Electric Code (NEC) tap rules How do they apply to circuit breaker terminals?

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Arktite Circuit Breaking CPS Receptacles and CPP Plugs Delayed Action Factory Sealed

NATURAL HIGH IMPACT STRENGTH COPPER FREE ALUMINUM Number of Wires VAC AT 50 TO 400 HZ/250 VDC

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Application Note Three Phase String Inverters NEC 2014 Compliance

HelioProtection HP15NH3L Photovoltaic fuse-links gpv 1500VDC

P SERIES POWERPLEX DISTRIBUTION PANELBOARDS SAFETY MADE SIMPLE

PowerPact Circuit Breakers for Control Panel Disconnects Class 0611

Photovoltaic System Overcurrent Protection

PowerPact Q-Frame Molded Case Circuit Breakers and Switches (Types QB, QD, QG and QJ)

6/4/2017. Advances in technology to address safety. Thomas A. Domitrovich, P.E., LEED AP VP, Technical Sales Eaton

Explosion Proof Receptacle - Integral Circuit Breaker - Class 2 Division 1-30 Amp 480VAC

Solar Power Switchgear & Energy Storage Renewable Energy Systems

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

1.1. Switching Devices

Service Entrance Methods

U-Line Contender Factory Sealed 20 Amp Plugs and Receptacles Explosionproof, Dust-Ignitionproof

SECTION PANELBOARDS

Compact Circuit Protector (CCP) Application Note

D2P and EWP Factory Sealed Circuit Breaker Panelboards Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

ENR Value Series Dead Front Interlocked Circuit Breaking Receptacles

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

Special Specification 6058 Battery Back-Up System for Signal Cabinets

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

Arktite Heavy Duty Circuit Breaking Plugs and Connectors

Complete and reliable solar circuit protection

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Advanced Guide To Understanding Assembly Short-Circuit Current Rating WITH ENGINEERING SOLUTIONS AND OVERCURRENT PROTECTION DEVICES TO ENHANCE SCCR

Selection Guide Motor Control Device Solutions

Hazardous Factory Sealed Control Devices

Solar PV Standard Electrical Plan

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

ARL2042 Receptacle. Long Description. Manufacturer Information PLUGS & RECEPTACLES GTIN Manufacturers Part Number UPC

Product Guide. NEMA pump controls.

Arktite Plugs and Receptacles Industrial Heavy Duty Hazardous

P-2 D2P and EWP Factory Sealed Circuit Breaker Panelboards: Explosionproof, Dust-Ignitionproof, Watertight, Corrosion-Resistant

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Effective December 2015 Supersedes September 2013

Technical catalog February 2017 Low Voltage Switchboards and Panelboards UL/CSA

FM9 Aluminum Unilet Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Safety Alert: Square D Safety Switches

Design Build Deliver. Metal Enclosed Switchgear, 5-35kV 1200 A Maximum Loadbreak, 4000 A Maximum Non-Loadbreak

Selective Coordination Enforcement:

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

LENRK/LESRK CLASS RK1 DUAL ELEMENT TIME-DELAY FUSES

Multi-Pak Group Control

Photovoltaic System Overcurrent Protection

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

Bolted contact switches. Pringle switches

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A, up to 1500 VDC

Plugs and Receptacles Industrial Heavy Duty Interlocked Non-Hazardous

FACTORY SEALED CIRCUIT BREAKER PANELBOARDS

General Specifications for Lighthouse Power Pedestal

ATLV MaxSG. Low Voltage Metal Enclosed Switchgear

FM9 Aluminum Conduit Outlet Bodies, Covers and Gaskets For use with Rigid Steel, Rigid Aluminum and IMC.

Hubbell Marine Isolation Transformers 15 kva and 25 kva Models

Michigan State University Construction Standards SECONDARY UNIT SUBSTATIONS PAGE

Application guide. Tmax Link OEM UL 891 Switchboard Program

Quik-Spec Coordination Panelboard Specifications

AMENDMENT ELECTRIC SERVICE MANUAL 2014

Fused Coordination Panelboard

UBW Family UL489 Molded Case Circuit Breakers

Selection Guide. Control Circuit and Load Protection

APJ Amp Pin & Sleeve Plug 3-W 4-P 250 VDC/600 Vac

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

Industrial Generator Set Accessories. Standard Features. Line Circuit Breakers kw

Control Circuit Protection

25.4. Molded Case Circuit Breakers. For Immediate Delivery or Tech Support call KMParts.com at (866) Contents

Arktite Heavy Duty Circuit Breaking Plugs and Receptacles

HelioProtection HP15NH Photovoltaic fuse-links gpv 1500VDC

Transcription:

Solar Combiner Solutions Providing combiners and disconnects that offer superior resistance and durability from harsh weather and abusive solar environments

Solar Technology Leading the way in Solar Technology Cooper Crouse-Hinds combiner boxes and disconnects for the solar market integrate a comprehensive line of electrical products with expert support, industry insights, and local availability to improve safety and productivity in the most demanding industrial, commercial and residential environments worldwide. Solar Background Information A solar array may be one panel or many in series, and may range from a single 12 volt panel up to multi-panel high voltage array for grid tie systems. Grid tie systems can go as high as 1000 VDC, while battery systems are typically 12, 24, or 48 V. Higher voltage systems (over 48 V) have different NEC code requirements than those for low voltage battery systems, and the two types are NOT interchangeable. Cooper Crouse-Hinds Solar Combiners are designed for higher voltage circuits used in grid tie and off-grid applications. All meet NEC requirements and are made in accordance with UL requirements. Cooper Crouse-Hinds Solar Combiners have additional breakers, disconnects, and fuses for the combined high current buss. Typical Solar Grid System Diagram Cooper Crouse-Hinds Supplied Components (CCBF04 setup shown) SOLAR ARRAYS (PANELS) COMBINER BOX DISCONNECT Combiner box also available with integral disconnect replacing the need for a separate disconnect INVERTER(S) Cooper Crouse-Hinds Product Offering Solar Combiners Cooper Crouse-Hinds Solar Combiners are used to group input wires/circuits from several arrays and/or solar panels. The combined circuit results in fewer output circuits and combines them into one main buss or feed going to the inverter saving labor and material costs. Solar Recombiners Cooper Crouse-Hinds Recombiners are used whenever PV output circuits are combined in the field, external to the inverter. Where inverter input circuits are combined internal to the inverter, we refer to this common connection point as an array combiner or recombiner. In practice, these terms are often used interchangeably. Solar Disconnects The National Electrical Code requires a disconnect switch which provides circuit interruption to the down stream inverter. The disconnect can be internally mounted to the combiner or externally mounted between the combiner and inverter. The disconnect switch can be located at one of two places: either inside the building nearest the point of entrance of the system conductors, or outside the building. If the solar disconnect is not located near the utility company's meter, then a plaque is required by the front door stating where the solar disconnect is located. Solar Cable Assemblies A comprehensive offering of solar cable assemblies are also available in molded to cable or mechanical termination configurations. Typical conductor size is #12 or #10. Available in standard or custom cable lengths. Consult factory for more details. Cooper Crouse-Hinds Solar Protection for Fiberglass Enclosures The Cooper Crouse-Hinds solar protection formula provides the enclosure the strength and durability to provide long, dependable service even in the most demanding environmental conditions. Cooper Crouse-Hinds fiberglass enclosures retain gloss and color even when exposed to harsh UV light and offer superior resistance to chemicals are fire retardant. A special UV absorber is added into this solar protection formula and works to absorb UV energy and release it without damaging the fiberglass enclosure thus providing increased protection of the polyester material and increased resistance to the damaging effects of UV radiation. For additional information on Cooper Crouse-Hinds Solar Protection, choose Fiberglass Enclosures from: http://www.crouse-hinds.com/contractorcorner Cooper Crouse-Hinds Solar Solutions email: solarsolutions@cooperindustries.com 2

Solar Combiners Solar Combiners Cooper Crouse-Hinds Solar Combiner Solutions are designed and built to minimize system costs by providing maximum flexibility. Solar Combiner Solutions offer a range of 1 to 48 input circuits, with a durable non-metallic (NEMA 4X) enclosure, engineered and manufactured to perform in the harshest environmental conditions. Built in accordance with UL1741 standard; providing peace of mind and plenty of wiring room for ease of installation. Built to UL 1741 Standards RATED FOR 1000 VDC - CONTINUOUS DUTY Built to UL 1741 Standards 75ºC output terminals Fiberglass enclosures provided as standard; also available in NEMA 3R painted steel or NEMA 4X stainless steel Touch-Safe fuse holders and power distribution blocks for safe operation Configured for positive and negative grounded arrays Integral disconnects available as an option (600 VDC) Enclosure Standard Materials/ Finishes Hot compression molded fiberglass reinforced thermoset polyester Non-conductive, impact resistant, UV resistant, flame retardant Captive cover screws can t be dropped or lost Poured polyurethane seamless gasket provides water-tight, dusttight environmental seal Stainless steel used on all external hardware Solar Combiners and Solar Combiners with Integral Disconnect Ordering Information SOLAR COMBINERS CCBF 12 F 15 Enclosure Type Number of Input Circuit Fused Fuse Amperage D CCBF (Fiberglass N4X) CCBS (Painted Steel N3R) CCBSS (Stainless Steel N4X) 01 (1 input circuit) 02 (2 input circuit) 03 (3 input circuit) 04 (4 input circuit) 05 (5 input circuit) 06 (6 input circuit) Offered up to 48 circuits F (Fuses provided) BLANK (Fuses not supplied by factory) 08 (8A fuse) 10 (10A fuse) 12 (12A fuse) 15 (15A fuse) BLANK (Fuses not provided by factory) Standards manufactured in accordance with IEC 60269 Volts: 1000VDC Amps: 8-15A Breaking Capacity: 33kAdc Min Interrupting:1.3 x I n See technical information (pg. 6) for more fuse information DS (Disconne 1-48 input CB (Circuit B use with 1 - BLANK (No integral d Cooper Crouse-Hinds Solar Solutions email: solarsolutions@cooperindustries.com 3

Solar Combiner with Integral Disconnect Solar Combiners with Integral Disconnect Cooper Crouse-Hinds Solar Combiners with Integral Disconnects provide all the strong and durable features of our standard Solar Combiners and are available with 1-48 input circuits. Integral disconnects save material costs, installation time and labor by joining the combiner box and disconnect within one enclosure and eliminating the need for a disconnect in a separate enclosure. RATED FOR 600 VDC - CONTINUOUS DUTY Built to UL 1741 Standards 75ºC output terminals Fiberglass enclosures provided as standard; also available in NEMA 3R painted steel or NEMA 4X stainless steel Touch-Safe fuse holders and power distribution blocks for safe personnel operation Configured for positive and negative grounded arrays Shown with Integral Disconnect Integral Disconnect Rating To determine the rating of the integral disconnect, simply multiply the number of input circuits by the ampacity rating of each fuse in these circuits. Round to the next (higher) trip rating. In NO case can the max current exceed the trip rating of the disconnecct switch or breaker. Example: a 12 stringer combiner box with every input circuit with a fuse rated at 8 Amps is 12 x 8 = 96. Required rating for the switch or circuit breaker would be 100 Amps. SOLAR COMBINERS WITH OPTIONAL INTEGRAL DISCONNECT CB 200 SP Integral isconnect ct Switch for use with circuits) reaker for 48 input circuits) isconnect) Disconnect Switch 100 (100A) 200 (200A) 400 (400A) See Table 2 BLANK (No integral disconnect) Trip Rating for Integral Disconnect Circuit Breaker 30 (30A) 50 (50A) 100 (100A) 125 (125A) 150 (150A) 175 (175A) 200 (200A) 225 (225A) 250 (250A) 400 (400A) See Table 1 BLANK (No integral disconnect) Surge Protection SP (Surge protection) Rated 15kA (10/350μs) per pole Type I Small size takes up minimal space in the enclosure (Only 1.5 inches wide) Highest fault current clearing, 100kA without backup fuses Thermal and short circuit fusing BLANK (No surge protection) Cooper Crouse-Hinds Solar Solutions email: solarsolutions@cooperindustries.com 4

Recombiners and Disconnect Switches Recombiners In large Photovoltaic (PV) systems, multiple combiner boxes are often necessary, and the outputs of these combiner boxes may need to be combined again recombined before reaching a central inverter. Cooper Crouse-Hinds Recombiners accommodate an increase in wire size, or, in the case of a subcombiner, a transition to the inverter DC input busbar, and they incorporate OCPDs for conductors. Combining PV output or inverter input circuits requires overcurrent protection whenever the combined fault current available at the busbar exceeds the ampacity of the upstream conductors. Consult Cooper Crouse-Hinds factory for ordering information. Heavy Duty Disconnect Switches Cooper Crouse-Hinds Solar Disconnect Solutions are used as a disconnecting means and rated for use as 600 VDC/AC. The disconnects are offered separately in a sheet steel enclosure or as an integral mounted device to the Cooper Crouse-Hinds Combiner Solutions, offering reduced space and cost of installation, the ability to disconnect power from a remote location, and provide short circuit protection. Switches are NEMA type HD heavy duty 3-pole, with visible blades; a quick make-and-break mechanism with reinforced, positive pressure type blade and jaw construction. Fusible types have fuse clips with steel reinforcing springs of positive pressure type. Pressure connectors are used for wire connectors. Switch enclosure covers are interlocked with the body and operating mechanism and cannot be opened when the plug is engaged and the switch is closed ("ON"). When the switch is open, the switch cannot be put in a closed ("ON") position with the door open. The switch operating handle may be padlocked in the "ON" or "OFF" position. In addition, a unique hinge arrangement has been devised to allow the door of the unit to be padlocked. This feature allows operation while preventing unqualified or unauthorized entry. Enclosure Standard Materials/ Finishes Enclosure sheet steel Operating handle non-metallic Other exterior parts stainless steel Enclosure Certification & Compliances NEMA Types 3R UL Standard 98 Electrical Rating Ranges 3 and 4 pole; fusible or non-fusible; 240 VAC/250 VDC; 600 VAC/600 VDC 30, 60, 100, 200 or 400 amperes Disconnect Switches Ordering Information Specifications Heavy Duty Safety Switch - 600 VDC Catalog Number - Fusible Catalog Number - Non-fusible 30 Amp, 3 pole 60 Amp, 3 pole 100 Amp, 3 pole 200 Amp, 3 pole Sheet Steel Fiberglass Sheet Steel Fiberglass Sheet Steel Fiberglass Sheet Steel Fiberglass CH361R CH361F CH362R CH362F CH363R CH363F CH364R CH364F CHU361R CHU361F CHU362R CHU362F CHU363R CHU363F CHU364R CHU364F For 4 pole 400 Amp or disconnect switches in a stainless steel enclosure - consult factory. Cooper Crouse-Hinds Solar Solutions email: solarsolutions@cooperindustries.com 5

Technical Information Combiner Technical and Dimensional Information Number of input circuits 1 TO 4 5 TO 6 7 TO 12 13 TO 20 21 TO 24 25 TO 28 29 TO 37 38 TO 48 CCBF_ CCBF_ CCBF_ CCBF_ CCBF_ CCBF_ CCBF_ CCBF_ Catalog number(i.e. CCBF12) (1-4) (5-6) (7-12) (13 TO 20) (21 TO 24) (21 TO 28) (29 TO 41) (42 TO 48) Maximum Input Fuse Rating (A) 15 15 15 15 15 15 15 15 Maximum Continuous Operating Current (A) Using Maximum Input Fuse 60 90 180 300 360 420 555 720 SCCR at 600VDC (KAIC) 10 10 10 10 10 10 10 10 Maximum Voltage (VDC) 600 600 600 600 600 600 600 600 Operating Voltage Range - Combiner Only(VDC) 0-1000 0-1000 0-1000 0-1000 0-1000 0-1000 0-1000 0-1000 Operating Voltage Range - Combiner With Integral Disconnect (VDC) 0-600 0-600 0-600 0-600 0-600 0-600 0-600 0-600 Positive Input Wire Size (AWG) #8-#18 #8-#18 #8-#18 #8-#18 #8-#18 #8-#18 #8-#18 #8-#18 Positive Input Terminal Torque (in-lbs) 16-22 16-22 16-22 16-22 16-22 16-22 16-22 16-22 Negative Input Wire Size (AWG) #10-#14 #10-#14 #4-#14 #4-#14 #4-#14 #4-#14 #4-#14 #4-#14 Negative Input Terminal Torque (in-lbs) 20 35 35 35 35 35 35 35 Positive Output Wire Size (AWG) 1/0-#10 1/0-#10 350kcmil-#6 (2) 300kcmil-#4 (2) 350kcmil-#6 (2) 350kcmil-#6 (2) 600kcmil-#2 (2) 600kcmil-#2 Positive Output Terminal Torque (in-lbs) 35 35 120 275 120 120 500 500 Negative Output Wire Size (AWG) 2/0-#8 500kcmil-#6 350kcmil-#6 (2) 300kcmil-#4 (2) 350kcmil-#6 (2) 350kcmil-#6 (2) 600kcmil-#2 (2) 600kcmil-#2 Negative Output Teminal Torque (in-lbs) 120 500 120 275 120 120 500 500 Ground Output Wire Sizes (AWG) #4-#14 #4-#14 250-#6 250-#6 250-#6 250-#6 250-#6 250-#6 Ground Output Terminal Torque (in-lbs) 20-35 20-35 275 275 275 275 275 275 Enclosure Nema Rating 3/3R/4/4X 3/3R/4/4X 3/3R/4/4X 3/3R/4/4X 3/3R/4/4X 3/3R/4/4X 3/3R/4/4X 3/3R/4/4X Enclosure Size 12X10X5 12X10X5 16X14X6 18X16X8 20X16X8 24X20X8 30X20X6 36X30X8 Maximum # of inputs 4 6 12 20 24 28 37 48 Overcurrent Protection - PV Fuse-Links Current Rating Energy Integrals (A2s) Power Loss (watts) Pre-Arcing Total at 1000V 0.8 In In. 8A 3 32 0.5 2.0 10A 7 50 0.6 2.1 12A 10 100 1.3 2.6 15A 20 200 1.8 3.0 Combiner Dimensional Information # of Input Circuits Enclosure Size Inches (HxWxD) Overall Dimensions Inches (HxWxD) Inside Dimensions Inches (HxWxD) Mounting Dimensions Inches (HxW) Approximate Weight (lbs) 1-6 12x10x5 13.56 x 11.43 x 5.21 11.79 x 9.80 x 4.94 12.75 x 8.00 10 7-12 16x14x6 17.53 x 15.46 x 6.23 15.63 x 13.60 x 5.94 16.75 x 12.00 18 13-20 18x16x8 19.62 x 17.61 x 8.82 17.69 x 15.69 x 8.45 18.88 x 12.00 27 21-24 20x16x8 22.00 x 17.68 x 8.83 19.72 x 15.72 x 8.45 21.25 x 10.00 33 25-28 24x20x8 27.00 x 21.24 x 9.90 24.05 x 20.39 x 9.25 25.75 x 14.00 47 29-37 30x20x6 32.86 x 20.99 x 7.89 29.90 x 20.14 x 7.23 30.75 x 14.25 60 38-48 36x30x8 39.31 x 32.50 x 10.05 36.31 x 31.69 x 9.36 38.13 x 23.88 112 Cooper Crouse-Hinds For P.O. 4 Box pole 4999 or 400A disconnect switches or NEMA 4X stainless enclosures information - consult factory Syracuse, NY 13221 Toll Free: (866) 764-5454 Fax: (315) 477-5179 FAX Orders Only: (866) 653-0640 crouse.customerctr@cooperindustries.com 4959-1109 Printed in USA