Plastic Flow Meters for gases & liquids, using TROGAMID* & POLYSULFONE Technology

Similar documents
Plastic tube variable area flowmeter for liquids and gases

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Flowmeters with Float. Flow Measurement of Gases & Clear Liquids with Float Series 6001 & Series 6001/ Measurement Principle.

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Flow switches Series AD/VH

Orifice plate flowmeters Series PR By-pass flowmeter for liquids, gases and steam

Level switches Series LC40 Float level switch for liquids

Oscillating piston flowmeters Series COVOL Positive displacement flowmeter for liquids

Metal tube variable area flowmeter for gases, liquids and steam

Metal tube flowmeters Series M21 Variable area flowmeter for low flows of liquids, gases and steam

Electromagnetic flowmeters Series FLOMAT Insertion electromagnetic flowmeter for conductive liquids

Electromagnetic flowmeters Series FLOMID Electromagnetic flowmeter for conductive liquids

Variable Area Flow Meters

Turbine flowmeters Series TM

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Flowmeter, Plastic 805 / 807 / 815 / / 825 / 832 / 835. Sectional drawing

KM-165, KM-185, KM-200 OVERVIEW. Flow Monitor & Flow Indicator. Features. Operation

Flowmeter DFM

GA 24 Heavy-duty variable area flowmeter

Oscillating piston flowmeter series COVOL Instructions manual

Operating Instructions for Plastic Flow Meter. Model: KSK

Flowmeter, Plastic 855 / 857 / 865 / / 875 / 880 / 885

Flap-Type Flow Meter Prall

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Technical Data. Flow Meter Schwertberg, Poneggenstr. 5 Austria/Europe Fax +43/7262/ Tel.

TORRIX Magnetostrictive level sensor

SATRON VTe pressure transmitter

RCM - Direct Reading Flowmeters

MWD. Industrial Temperature Assemblies RTD. Meassuring range ºC. Pt100 sensor class A, class B, class 1/3, class 1/10, or Cryogenic.

Magnetic Inductive Flowmeter EP / UMF2 (B)

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Installation and Operating Instructions. Variable area flow meter RA 65 / FA 65

Visual Level Indicators (VLI) Plastic & Top of Tank Series Series Type Material Pipe Operating Operating Page

Magnetic Paddle Flow Sensor/Switch for Easy On/Off Control

display on the wall or in a panel away from the inline sensor SE30 for easy meter reading.

COVOL. Operating Data. Areas of Application. Measuring Ranges. Method of Operation. Fields of operation. Features. Installation information

ORIMAS Mass Flowmeter

BM 26 BASIC/ADVANCED Technical Datasheet

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Miniature Float Switches

Primus 221 offers optimum dosing accuracy and operating convenience. The dosing flow variation is only ± 1,5 %

MINI-NBK ECONOMICAL LEVEL INDICATOR

The EPSILON is based on the principle of measuring velocity in the pipe line, therefore the flow measurement is volumetric.

INSTALLATION AND OPERATION

Corrosion Resistant and Ultra-Pure Rotameters for Accurate Measurement of Liquids and Gases

Diaphragm Valve, Plastic 2/2 way, motorized

HG5 Series. Metal Tube Rotameter CATALOG MAIN FEATURES TECHNICAL PARAMETERS

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

STEEMCO-MAS Flowmeter for Steam

STEEMCO Flowmeter for Steam

SITRANS P measuring instruments for pressure

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

BM 26 BASIC/ADVANCED Technical Datasheet

SATRON VT Pressure Transmitter

Magnetic-inductive flow meter EPS / UMF2. Technical data sheet

Float switch For industrial applications, with temperature output Model RLS-3000

Differential-Pressure Flow Meter

Assembly and operating Instructions

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.

Control Components Pty Ltd. Drawing Number. Indicator Model Overview A 66.01A Side flanged connection

Insertion magnetic inductive flowmeter

magnetic flow meters Johannesburg (Head Office) Technical Data Safmag Wafer Type

General Specifications

Industrial OG meter series IOG Inline and flanged oval gear meter

Valves for building. Y-strainers... page 204 PVC valves Ball valves... page 204 Butterfly valve... page 204 Ball check valve...

Flow-rate curves for diaphragm valves Type 2730 plastic, 2731 forged, 2731 cast, 2731 GP cold formed pipe valve body

/ 855 / 857 / 861 / / 870 / 875 / 880 / 885. Variable Area Flowmeter, Plastic

Digital ph transmitter

유량계전문제조업체. Electro Magnetic FLOWMETER

ISTEC MAGNETIC METERS

Assembly and operating Instructions RA 60 / FA 60

Flow Measurement SITRANS F C. Flow sensor MASS 2100 DI 3 to DI 40. 4/180 Siemens FI

Valves for building. Y-strainers... page 272 PVC valves Ball valves... page 272 Butterfly valves... page 272 Ball check valves...

HH5 Variable Area Flow meter

Control Components Pty Ltd. PO Box 212 Caringbah NSW 1495 Sydney Australia ph: +61 (0) fx: +61 (0)

Resistance thermometer Model TR10-L, Ex d, for additional thermowell

Digital ph transmitter

Ar-Mite TM Low Flow Armored Flowmeter

2/2-way ball valve with electric rotary actuator, ball valve in plastic, DN 10-50

Modulating control valve PN16 with magnetic actuator

Pressure transmitter for industrial applications Type MBS 4510

VALVES WITH SA ELECTRIC ACTUATOR

2 way ball valve S4 with pneumatic actuator

CombiTemp Temperature Measuring System

F6700 ELECTROMAGNETIC METER

For industrial applications For marine applications With proximity switch. Piston type flow switches

Resistance thermometer Model TR10-E, for additional thermowell

Variable Area Flow Meters RA 65 / FA 65

SATRON VDt Differential Pressure Transmitter

ARBO. ARBO Magnetic drive pumps. Pompen en Filters b.v. Product group 2.2

Pressure transmitters for heavy duty applications MBS 3200 and 3250

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

KDM ARMORED FLOW METER & SWITCH

PMG MAGNETIC FLOWMETER

Vortex Flowmeters VFM 3100 F-T VFM 3100 W-T

2/2 Pressure operated valves

A Higher Level of Performance. Data Sheet. Centurion. Guided Radar. CGR Series. For more information, please visit >

Modulating control valve PN16 with magnetic actuator

Electromagnetic Flow Monitor magphant

Transcription:

Plastic Flow Meters for gases & liquids, using TROGAMID* & POYSUFONE Technology Applications Monitoring & Control of processes for: Water & Waste Water Treatment Chemical, Petrochemical & Paper Pharmaceutical, Cosmetics & Synthesis Refrigeration & Air Conditioning Refining Osmosis Gas processes Benefits ow cost Excellent readability Scaled directly in l/h, m 3 /h, %, etc. Temperatures up to 60 o C TROGAMID*, and 90 o C POYSUFONE Pressures up to 15 bar Simple installation (flanged, threaded or glued connections) ight weight High & ow Flow Switches 4-20 ma Output (18 points max.) (On request HART, PROFIBUS, FIEDBUS protocols) * TROGAMID is a registered trade mark of Dynamit Nobel.

Type AC Reading line Type ACT Measurement Principle Variable area flow using a float in a tapered tube made from special plastic materials. Operation The fluid flows up through the tapered tube forcing the float to a position with sufficient free area to enable the flow to pass. This free area is related to the flow rate, the weight of the float and the density and viscosity of the fluid. The pressure drop across the flow meter remains constant over the entire flow range. This occurs because the pressure drop is related to the fluid velocity and area of flow, the area of flow increases as the flow rate increases. Reading Reading Technical Data Connections: PT-11 & PS-31: Threaded or glued fittings from 1/2 to 3 BSPF PT-12 & PS-32: Flanges DN 15 to DN 80, PN 10 PTM-01 & PSM-21: Threaded or glued fittings of 1/2 and 3/4 BSPF PTM-02 & PSM-22: Flanges DN 15 and DN 20, PN 10 Other connections available on request ength (in mm) Minimum Maximum PT-11 340 414 PT-12 390 538 PT-12 (BR) 380 420 PTM-01 / PSM-21 232 +1 mm PTM-02 / PSM-22 260 +1 mm Accuracy: PT & PS: According to Standards VDE / VDI Class 4 PTM & PSM: According to Standards VDE / VDI Class 6 Scales calibrated directly in l/h, m 3 /h, % Scale length: PT & PS: 160 +5 mm PTM & PSM: 100 +5 mm Rangeability: 10:1 Pressure: up to 15 bar @ 20 o C NOTE: a more cost effective PTM Series flow meter is available from stock, the model PTM-03 with NAS 30 clear performance plastic. Available flow rates and options, same as PTM Series. Temperature imits: PT-TROGAMID T tubes: 60 o C PS-POYSUFONE tubes: 90 o C PTM-TROGAMID T tubes: 60 o C PSM-POYSUFONE tubes: 90 o C PVC fittings: max. 55 o C PP fittings: max. 90 o C Materials: Flow tube Fittings Float Float Stops PT-TROGAMID T EN 1.4404 (SS-316) PVDF+ ead PS-POYSUFONE PVC Aluminium PP PTFE PVDF PTM-TROGAMID T SS-316 PTFE+ead Steel PVC PSM-POYSUFONE PVC + ead Alarm Options: PT-AMR 1...2 Magnetic actuated reed switch Transmitter Options: PT-TMUR 0...4-20 ma (16...18 points resolution for Series PT-PS) PTM-TMUR 0...4-20 ma (11 points resolution for Series PTM-PSM) NAS is a registered trade mark of NOVA Chemicals Inc. 2

PT-11, PS-31/PTM-01, PSM-21 PT-12, PS-32/PTM-02, PSM-22 PT-12(BR), PS-32(BR) Nº Item PT-11/12,PTM-01/02,PT-12(BR) PS-31/32,PSM-21/22,PS-32(BR) On demand 1 Flow tube TROGAMID T POYSUFONE PVDF 2 Float EN 1.4404 (SS-316), EN 1.4404 (SS-316), PTFE, PTFE+ead, PVDF+ead, Aluminium PVDF+ead, Aluminium Hastelloy, Titanium 3 Fitting PVC PVC PP, Steel, SS-316 4 Nut PVC PVC PP, Steel, SS-316 5 Gasket NBR NBR Viton, EPDM 6 Float Stop PVDF PVDF - 7 Flow Indicator PVC PVC - 8 Tube Union PVC PVC - 9 Flange (glued) PVC PVC - 10 Flange Neck PVC PVC PP PTM + PTM-TMUR PTM + PTM-AMR PT + PT-TMUR PT + PT-AMR 3

PT-11 / PS-31... PT-12 / PS-32... PT-12(BR) / PS-32(BR) Flow Tube Measuring Ranges vs Float Type AC Max. P mm H 2 O Tube Series Series PT Operating PT-11 Series PS* Pressure PT-12 EN 1.4404 AUMINIUM PS-31 7.95 g/cm 3 2.85g/cm 3 Float PS-32 PT-12(BR) Model Nº Water 20 o C Air@STP Air@STP ength PS-32(BR) l/h Nm 3 /h Nm 3 /h bar EN 1.4404 AUM. mm Min. Max. Min. Max. Min. Max. (+1mm) DN E PT-312-0160 (1) * 16 160 - - 0.6 6 15 90 (1) - 300 15 20 PT-312-0250 (1) * 25 250 - - 1 10 15 90 (1) - 300 15 20 PT-313-0400* 40 400 1.1 11 0.7 7 15 125 50 300 20 25 PT-313-0630* 60 630 1.8 8 1 10 15 125 50 300 20 25 PT-313-1000* 100 1000 3 30 1.7 17 15 125 50 300 20 25 PT-314-1600* 160 1600 4.5 45 2.5 25 10 175 75 300 25 32 PT-314-2500* 250 2500 7 70 4 40 10 175 75 300 25 32 PT-315-4000* 400 4000 11 110 7 70 10 230 95 300 40 50 PT-315-6300* 500 6300 18 180 10 100 10 230 95 300 40 50 PT-316-6300 500 6300 18 180 10 100 10 300 125 300 50 63 PT-316-M010* 1000 10000 30 300 17 170 10 300 125 300 50 63 PT-316-M014* 2000 14000 120 420 45 200 10 300 125 300 50 63 PT-317-M016 1600 16000 45 450 25 250 8 400 170 300 65/80 75/90 PT-317-M020 2000 20000 60 600 35 350 8 400 170 300 65/80 75/90 PT-317-M025 2500 25000 70 700 40 400 8 400 170 300 65/80 75/90 PT-317-M030 3000 30000 90 900 50 540 8 400 170 300 65/80 75/90 PT-317-M040 6000 40000 180 1200 100 712 8 400 170 300 65/80 75/90 PT-317-M040 (3) 8000 50000 240 1500 150 900 8 400 170 300 65/80 75/90 (1) With PTFE float (2) NOTE: for PT and PS Series, all plastic loaded floats are in PVDF+ead, except for the tubes with model nº PT-316-M014, PT-317-M016, PT-317-M020, PT-317-M025, PT-317-M030, PT-317-M040 where the material for the float is PVC+ead (3) Fits special float to reach higher flow rate * Flow tube available in Polysulfone PTM-01 / PSM-21... PTM-02 / PSM-22 Flow Tube Measuring Range vs Float Type AC Max. Pressure Drop Tube Series Series PTM Pressure P mm Water PTM-01 Series PSM* PTM-02 EN 1.4404 (1) Aluminium PSM-21 7.95 g/cm 3 2.85 g/cm 3 Float PSM-22 Model N o Water 20 o C Air @ STP Air @ STP ength I/h Nm 3 /h Nm 3 /h bar EN 1.4404 (1) Al mm Min. Max. Min. Max. Min. Max. (+1mm) DN E PTM-312-0040 (2) * 4 40 - - 0.12 1.5 15 (2) 30-192 15 20 PTM-312-0060 (2) * 6 60 - - 0.2 2 15 (2) 30-192 15 20 PTM-312-0100* 10 100 0.3 3 0.15 1.8 15 90 35 192 15 20 PTM-312-0160* 16 160 0.5 5 0.25 2.5 15 90 35 192 15 20 PTM-312-0250* 25 250 0.7 7 0.4 4 15 90 35 192 15 20 PTM-313-0400* 40 400 1.1 11 0.7 7 15 125 50 192 20 25 PTM-313-0630* 60 630 1.8 8 1 10 15 125 50 192 20 25 PTM-313-1000* 100 1000 3 30 1.7 17 15 125 50 192 20 25 (1) EN 1.4404 = SS-316 (2) With PTFE float * Flow tube available in Polysulfone 4

PT-11 / PS-31 Rp = DN E RE A 1 2 H 1/2 15 20 1 43 340 300 307 17 3/4 20 25 1 1/4 53 346 300 309 19 1 25 32 2 74 352 300 311 22 1 1/2 40 50 2 1/4 80 366 300 314 31 2 50 63 2 3/4 99 372 300 314 38 2 1/2 65 75 4 135 378 300 318 44 3 80 90 4 135 414 300 318 51 PT-12 / PS-32 & PT-12(BR) / PS-32(BR) DN E D k g lxnº B (BR) 15 20 95 65 45 14x4 12 390 380 20 25 105 75 58 14x4 13 396 380 25 32 115 85 68 14x4 15 412 390 40 50 150 110 88 18x4 17 446 400 50 63 165 125 102 18x4 20 458 41 65 75 185 145 122 18x4 21 490 420 80 90 200 160 138 18x4 22 538 420 PT-11 Ø A PT-12 Ø D PT-12(BR) Ø RE Ø K PS-31 PS-32 PS-32(BR) Ø g Ø E Ø E Rp DN DN H B B 2 1 PTM-01 / PSM-21 Rp = DN E RE A 1 2 H 1/2 15 20 1 43 232 192 198 17 3/4 20 25 1 1/4 53 232 192 198 19 PTM-02 / PSM-22 DN E D k g lxnº B 15 20 95 65 45 14x4 12 257 20 25 105 75 58 14x4 13 260 PTM-01 PSM-21 Ø A Ø RE Ø E Rp PTM-02 PSM-22 Ø D Ø K Ø g Ø E DN H B 2 1 5

Adjustable imit Switches PT-AMR (from 25-250 l/h H 2 O, and 0.8-8 Nm 3 /h air) Adjustable imit Switches PTM-AMR (from 6-60 l/h H 2 O, and 0.2-2 Nm 3 /h air) Reed switch, actuated by a magnet inside the float. Mounted within a PVC enclosure: PT-AMR & PTM-AMR 1...2 Adjustable reed switches Operation: The contact is normally open, when not in alarm condition Maximum Flow: On increasing flow, the contact closes when the float reaches the height of the alarm sensor. It remains closed while the float is above the sensor. It opens again when the flow reduces and the float returns below the sensor. Minimum Flow: On reducing flow, the contact closes when the float reaches the height of the alarm sensor. It remains closed while the float is below the sensor. It opens again when the flow increases and the float rises above the sensor. Normally Closed reed switches are available on order. Technical Characteristics Material: PVC housing Ambient temperature: -15 to 60 o C Contact rating: 0.5 A / 250 VDC / 12 VA Hysteresis: +5% of full scale value Ingress protection degree: IP65 DIN 43650-A connector, PG9 cable gland Conforms to 73/23/EEC Directive Electrical Connection In the female connector (A): Terminal 1: Reed switch contact Terminal 2: Reed switch contact Terminal 3: No connection Earth terminal: No connection 2 3 1 Mounting Once the electrical connection has been made and the cable gland has been tightened, mount the female connector (A) on the male base (C), placing the seal (B) between the two pieces. A B To fix the limit switch in its position on the flowmeter, unscrew the screw (E) to release the bracket (D), situate the limit switch on the desired point at the tube and reassemble the bracket by tightening the screw (E). PTM/PSM PT/PS PT-11/12...PS-31/32 & PTM-01/02...PSM-21/22 DN 15 20 25 40 50 65 80 R 1/2 3/4 1 1 1/2 2 2 1/2 3 A 47 52 62 70 70 90 90 C 18 42 70 9,5 D A E 6

Transmitter PT-TMUR 0/4-20 ma (16...18 point) (from 25-250 l/h H 2 O and 0.8-8 Nm 3 /h air) Transmitter PTM-TMUR 0/4-20 ma (11 points) (from 6-60 l/h H 2 O and 0.2-2 Nm 3 /h air) The TMUR electric transmitter consists of a chain of reed switches which is mounted inside a plastic enclosure IP-65 rated which is attached to the side of the flow tube and a separated converted TR420 which converts the resistance in to current (0...4-20 ma). The converter TR420 can be installed by means of screws or in a DIN 46277 rail. TR420 Converter Technical Data: Power supply: 110, 230, 240, 24 V ac 50/60 Hz 24 V dc Max. Power: < 1 VA Accuracy: +0.1% Working Temperature: 0 o C +60 o C Electrical connection: 4 wires, standard 2 wires, on demand Resolution: 10 mm (On request HART, PROFIBUS, FIEDBUS protocols) PTM/PSM + PTM-TMUR TR420 Converter TR420 (converter Ω/mA) Information for order a / vvv PT-11/12... PS-31/32 y PTM-01/02... PSM-21/22 DN 15 20 25 40 50 65 80 A 95 105 110 120 130 145 145 PT-11/PS-31... PT-12/PS-32 with TMUR PT/PS + PT-TMUR PTM-01/02... PSM-21/22 55 75 110 4,5 x 6 37,5 61,2 a = Output signal = A 0-20 ma = B 4-20 ma = D 0-5 V dc = E 0-10 V dc = F 1-5 V dc = G 2-10 V dc vvv = Supply = 110 110 V ac 50/60 Hz = 220 220-230 V ac 50/60 Hz = 240 240 V ac 50/60 Hz = 024 24 V ac 50/60 Hz = 24d 24 V dc A 30 *PTM... PSM 139 mm 48 DN15 - DN50 = 215* DN65 - DN80 = 195 7

Optional connections PT-11/INOX (SS 316 = EN 1.4404) Rp 1/2... 3 BSP/NPT PT-11/INOX (SS 316 = EN 1.4404) for welding DN15... DN80 PT-11/PP Rp 1/2... 3 BSP PT-11 with nuts in PVC and metallic end connectors: PT-11/Fe, end connector in steel PT-11/INOX, end connector in SS 316 = EN 1.4404 Rp 1/2... 3 BSP/NPT R+D, Manufacturing and assembly workshop Machine shop Sales department and calibration facilities Glass workshop Ref. PT- 02/06 P-3481 We are at your service, please consult us. TECFUID develops and manufactures instruments for gases and liquids, using the most advanced techniques. Request information by telephone nº: +34 93 372 45 11 C/. Narcís Monturiol, 33-08960 SANT JUST DESVERN (BARCEONA) International: Telephone. +34 93 372 45 11 - Fax +34 93 473 44 49 www.tecfluid.com - e-mail: tecfluid@tecfluid.com The technical data in this pamphlet is subject to modification without notification, if the technical innovations in the product or manufacturing processes so require.