Contactor Combiner Box Installation Manual

Similar documents
Disconnect Combiner Box Installation Manual

Combiner Box Installation Manual

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

Sunny Boy Accessories SUNNY BOY COMBINER BOX TLUS SBCBTL6

Sunny Central Accessories SUNNY CENTRAL STRING-MONITOR US

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Installation Guide. Trace Combiner Box 6

Residential Transition Box. Model RU-1. Specifications. Electrical

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

Acme Conduit Entry. String Combiner/Pass-Through. FOR PHOTOVOLTAIC INSTALLATION Installation Manual

GS-IOB-120/240VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

Model LA 4300 Time Delay OFF Controller

Model LA 4400 Time Delay OFF Controller

Solar Inverter SUNNY BOY 5000US / 6000US / 7000US

Model LA 4100 Time Delay OFF Controller

MIL-24/2600Q MIL-24/3200DQ

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Patient Care Facility

Model C230 Pump Controller

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

F-4600 INLINE ULTRASONIC FLOW METER Installation and Operation Guide

Model Description Vac. Max rating Pedestal Only: 36 Utility Pedestal W/O Disconnect General Duty Series:

OWNERS MANUAL JANUARY 2007 ISO

Outdoor Nema Enclosure For Dotworkz CoolDome Power Supply Product Code: NM-CDPS. User Manual

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

INSTRUCTIONS FOR THE RELIANCE CONTROLS ARM SERIES AUTOMATIC TRANSFER SWITCH

Micro Inverter with Communication Unit SUNNY BOY 240-US SUNNY MULTIGATE-US

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

Model HPX60 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

Operations Manual. Zero Speed Switch Sensor Model ZS09P

PowerWorx Power Distribution Products Select Series Circuit Breaker for ±24 or ±48 Vdc User Manual

Safety and Installation Instructions

24/3000H-3PH 24/4500H-3PH 24/6000H-3PH

Solar Power Installation Application

Model APS 3B Snow and Ice Melting Control

Patient Care Facility

Drug Testing Labs. Style 2 W/ Ver 4.41 pcb & Pulse Relay pcb(s) Installation, Operations, Start-up and Maintenance Instructions

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Monicon Instruments Co., Ltd. CHR-1285/2485 CHR-1285/2485 BATTERY CHARGER

Bulletin 1494M Fixed Depth Remote Operated Disconnect Switches Renewal Parts

miconverter 18-Module Rack-Mount Power Chassis User Manual 38 Tesla, Irvine, CA USA Phone: (949) ; Fax: (949) Page 12

MaxLite StaxMax LED Flood Lights

GS-IOB-230VAC. Input/Output/Bypass Assembly. Installation Instructions. Purpose. Scope. Requirements. Grounding Instructions

OWNERS MANUAL JANUARY 2007 ISO

DC to AC Power Inverters

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

DC to AC Power Inverters

BMRX Series ROTARY LEVEL CONTROL

Quick Connection Panel (QCP) Installation Guide

LIGHTNING PROTECTION UNIT (LPU)

CPS 3Phs String Inverters NEC 2014 Compliance

Model NTX7 Series Automatic Battery Charger User s Manual Rev. 1.0 October 17, 2006

INSTRUCTIONS FOR THE RELIANCE Fast/Tran TM ARL0909 & ARL0909R

WattStation Wall Mount User Manual

OnBoard Drum Major Podium

Installation Manual. Rev

2016 Photovoltaic Solar System Plan Review List

ADI-125/750 ADI-125/1500 ADI-125/2500

OPERATING INSTRUCTIONS PLEASE READ CAREFULLY

CONTACTS RELAY TESTER 66249

Owner's/Installation Manual

MNPVHV Disco Installation Instructions

READ THIS BEFORE INSTALLING SWITCHGEAR

100A 225A 400A PATENT PENDING

PowerWorx GMT Series Power Distribution Panel Uninterrupted (C-Source) Power User Manual

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

Mechanical Spiral Sensor

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Product guide. Enclosed NEMA starters. usa.siemens.com/controls

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Owner's Manual. GenReady Load Center and Transfer Switch. This manual should remain with the unit. Model Numbers. GenReady Basic Panelboard

MODEL SIT -6E PAVEMENT-MOUNTED SNOW AND ICE SENSOR

Central Inverter SUNNY CENTRAL 500U

REFERENCE MANUAL FORM: MX-TRM-E REL REV MTE

The LED Driver Expert

SineWave Guardian TM 380V 600V INSTALLATION GUIDE. Quick Reference. ❶ How to Install Pages 6 17 ❷ Startup/Troubleshooting Pages WARNING

High Frequency SineWave Guardian TM

TECHNICAL BRIEF Americas

CONTACTS EGR VALVE TESTER 66248

Solar Combiner Solutions

Technical Manual. DLM Module. This manual should remain with the unit.

END USER TERMS OF USE

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Installation Manual Stand-Alone Dispenser Pan Sensor

Universal Battery Holder Operator s Manual

ISIMET/MAPA, LLC, an affiliate of WCM Industries, Inc. 103 CJ Wise Parkway Naples, TX (903) fax (903)

Patient Care Facility Multiple Room Configuration Style 3 W/ Ver 4.41 pcb & Pulse Relay pcb(s)

ELECTRONIC FIREPLACE DAMPER

Operator s Manual. Fairbanks FH Series by Fairbanks Scales, Inc. All rights reserved. . Revision 1 06/2017

Copyright 2012 DelSolar Co. Ltd MQWRD installation manual-iec Ver. 1.4

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

SunWize SWPB Series Solar Modules GENERAL INSTALLATION & USER GUIDE

CTFRP Series Power Supplies

APPROACHING. The Inverter. 92 IAEI NEWS May.June approaching the inverter

Freedom egen System End-of- Line Functional Checklist

BMRX Series Rotary Level Indicator

Sunwize Power Ready Express Quick Start

RK Standby Battery Operator s Manual

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

Transcription:

Contactor Combiner Box Installation Manual SolarBOS, Inc. 310 Stealth Court Livermore CA 94551-9552 925-456-7744 ph. 925-456-7710 fax www.solarbos.com

Copyright 2008 SolarBOS, Inc. All rights reserved. All rights reserved. No part of this document may be reproduced, stored in a retrieval system, or transmitted, in any form or by any means, electronic, mechanical, photographic, magnetic, or otherwise, without the prior written permission of SolarBOS, Inc. SolarBOS makes no representations, express or implied, with respect to this documentation or any of the equipment and/or software it may describe, including (with no limitation) any implied warranties of utility, merchantability, or fitness for any particular purpose. All such warranties are expressly disclaimed. SolarBOS is not liable for any indirect, incidental, or consequential damages under any circumstances. (The exclusion of implied warranties may not apply in all cases under some statutes, and thus the above exclusion may not apply.) Specifications are subject to change without notice. Every attempt has been made to make this document complete, accurate and up-to-date. Users are cautioned, however, that SolarBOS reserves the right to make changes without notice and shall not be responsible for any damages, including indirect, incidental or consequential damages, caused by reliance on the material presented, including, but not limited to, omissions, typographical errors, arithmetical errors or listing errors in the content material. Revision History Rev. No. Date By Description 1.0 12 Jan 2010 AS Preliminary Release 1.1 27 Jan 2010 JS Revised pgs 6-7 1.2 13 Apr 2010 AS Control Wire revision 1.3 3 Oct 2011 CS 350A 1.4 17 March 2014 WC Torque Values SolarBOS, Inc. 310 Stealth Court Livermore CA 94551 925-456-7744 ph. 925-456-7710 fax www.solarbos.com 1

IMPORTANT SAFETY INSTRUCTIONS ***SAVE THESE INSTRUCTIONS*** This manual contains important instructions for all SolarBOS contactor combiner box models that must be followed during the installation and use of the combiner boxes. The contactor combiner boxes are designed and tested according to international safety requirements, but as with all electrical and electronic equipment, certain precautions must be observed when installing the contactor combiner boxes. To reduce the risk of personal injury and to ensure the safe installation and operation of the contactor combiner boxes, you must carefully read and follow all instructions and warnings in this Installation Guide. Safety and Hazard Symbols Warnings This symbol appears beside instructions and warnings that deal with dangerous voltages that can injure people who come in contact with them. WARNING: A warning describes a hazard to equipment or personnel. It calls attention to a procedure or practice, which, if not correctly performed or adhered to, could result in damage to or destruction of part or all of the SolarBOS equipment and/or other equipment connected to the SolarBOS equipment or personal injury. Warnings may also be accompanied by one or more of the safety and hazard symbols described above to indicate the type of hazard described therein. Other Symbols In addition to the safety and hazard symbols described previously, the following symbol is also used in the Installation Guide: This symbol accompanies notes that call attention to supplementary information that you should know to ensure optimal operation of the system. This GROUND symbol marks areas in the combiner box for connecting equipment grounds only. 2

Warranty All contactor combiner boxes sold in the USA have a one-year warranty. For warranty coverage, or if you have questions about the current monitoring array combiner box warranty, contact SolarBOS at the address, telephone number, or Web Site listed on page 1 (to send e-mail, see the Contact section of the SolarBOS Web Site: www.solarbos.com). WARNING: The contactor combiner boxes use an integrated contactor and disconnect switch, yet both the line and load side of the contactor may still be energized when the contactor is OFF. Always test both sides of the contactor before servicing the contactor combiner. WARNING: All electrical installation must be done in accordance with the National Electrical Code ANSI/NFPA 70, local building codes, and the requirements of the authority having jurisdiction. WARNING: To prevent electrical shock or injury, all wiring and commissioning procedures must be performed by qualified personnel. WARNING: Before installing or using the current monitoring array combiner box, read all of the instructions and warnings on the array combiner box and in this Installation Guide. WARNING: PV arrays produce electrical energy when exposed to light and thus create an electrical shock hazard. WARNING: Never open a fuse holder while it is under load. Electrical arcing and damage to the fuse holder will occur if a fuse holder is opened under load. 3

Introduction SolarBOS has introduced a new line of PV contactor combiner boxes designed for use with all module and inverter combinations. Combiner box features include: Listed to UL 1741 Compact, low-cost, and flexible design Available in NEMA 3, 3R, 4 powder-coated steel, and NEMA 4X stainless steel or fiberglass enclosures Integrated load-break contactor Contactor over-ride switch Unpacking and Inspection All SolarBOS contactor combiner boxes are thoroughly checked before they are packaged and shipped. Although they are shipped in sturdy packaging, damage can still occur during shipping and delivery. It is important to carefully inspect the shipping container and contents prior to installation. If you detect any external damage after unpacking, report the damage immediately to SolarBOS and the shipping company that delivered the unit. Items not rejected within 10 days of delivery are considered accepted without recourse. If it becomes necessary to return the combiner, please use the original packing material. If you need assistance in dealing with a damaged unit, contact SolarBOS at 925-456-7744. 4

Installation Refer to Figure 1 and Table 1 for enclosure dimensions. Use appropriate hardware for the mounting surface. The weight of the unit is shown in Table 1. Figure 1 Combiner Enclosure Dimensions Table 1 Contactor Combiner Dimensions and Weights Enclosure Type Max. Output # input strings H W D X Y (lbs.) Weight N3/N4/4XSS 200 ADC 8-18 20 20 6 18.5 18.5 48 N3/N4/4XSS 200 ADC 20-36 24 24 6 22.5 22.5 55 4XF 200 ADC 8-18 26 22 8 18.75 26.85 30 4XF 200 ADC 20-36 26 26 8 22.75 26.85 40 N3/N4/4XSS 350 ADC 8-18 20 20 6 18.5 18.5 48 N3/N4/4XSS 350 ADC 20-36 24 24 6 22.5 22.5 55 4XF 350 ADC 8-18 26 22 8 18.75 26.85 30 4XF 350 ADC 20-36 26 26 8 22.75 26.85 40 NOTE: SolarBOS contactor combiner boxes are rated for continuous duty operation. Contactor Combiner Orientation NEMA-3R enclosures may only be installed in the vertical orientation. This applies to contactor combiners with the 3R designation. NEMA-3R/4/4X enclosures may be installed in either the vertical or the horizontal orientation. This applies to contactor combiners with the N3 N4 4XF and 4XSS designation. The over-ride switch external handle base carries a NEMA-4X rating. 5

Contactor Combiner Assembly The contactor combiner contains an integrated contactor to break the circuit from the combiner to the inverter when the contactor is turned OFF. This contactor can be turned OFF by de-energizing the power supply near the inverter, or by using the over-ride switch. Contactor Combiner Wiring The contactor combiner contains a normally open contactor which requires a 24 VDC power supply (sold separately see SolarBOS website for power supplies). The power supply inputs should be connected to the disconnect switch using the connections labeled "(+)" and "(-)" (see Figure 2). Positive input from power supply Negative input from power supply Figure 2 Contactor Combiner Connections Contactor Combiner CS200C-14-15-N3 shown 6

Low Voltage Control Wiring The contactor combiners require power to be supplied by an external power source. When providing power to the contactor combiners, note that multiple contactor combiners can be connected in parallel to utilize a single power supply. See Figure 3. Figure 3 Contactor Combiner Line Diagram 7

600 VDC Input Wiring Refer to Figure 5 and Table 2 for the input wiring locations of the contactor combiner box. PV positive and negative conductors are wired into the positive lug and negative distribution block, respectively. These terminal locations are clearly marked. All PV safety ground conductors are wired into the ground bus located at the bottom of the current monitoring array combiner box. NOTE: The contactor combiner enclosure is shipped with no entry holes. A knock-out is required for the appropriate conduit size. SolarBOS recommends wire entry be made according to Figure 5. 600 VDC Output Wiring When temperature and voltage drop adjustments are considered, the output conductor sizes can become quite large (500 MCM or greater) and difficult to manage. NEC Article 310.4 allows paralleling of conductors greater than AWG 1/0 to achieve higher ampacities. Most SolarBOS contactor combiner boxes provide output terminals for paralleling two conductors for the PV positive and negative, as well as the equipment ground conductors. Refer to Figure 4 and Table 2 for the output wiring locations. NOTE: On units with provision for using crimp lugs use Panduit part number LAA250-38-5 for 250MCM wire or a UL listed equivalent part from another manufacturer. Be sure to use the appropriate part number for the intended wire gauge. NOTE: Raintight or wet location hubs that comply with the Standard UL514B must be used for NEMA 3/3R outdoor applications. NEMA 4 or 4X applications must use watertight hubs that comply with the Standard UL514B. Use Myers-type, water-tight conduit fittings such as Thomas & Betts H200TB (for 2 conduit) or H300TB (for 3 conduit) or equivalent from others. Install fittings per manufacturer s recommendations. 8

Figure 5 Combiner Wire Entry Locations Dimensions A, B, C, and D are for input and output wire locations. These locations are recommendations only. Care should always be taken to assure there is enough wire bend space for the desired output wire gauge when choosing a conduit entry location. Table 2 Wire Entry Dimensions Enclosure Type Max. Output # input strings A B C D N3/N4/4XSS 200 ADC 8-18 20 5 8 20 N3/N4/4XSS 200 ADC 20-36 24 7 10 24 4XF 200 ADC 8-18 20 7 10 20 4XF 200 ADC 20-36 24 7 10 24 N3/N4/4XSS 350 ADC 8-18 20 5 8 20 N3/N4/4XSS 350 ADC 20-36 24 7 10 24 4XF 350 ADC 8-18 20 7 10 20 4XF 350 ADC 20-36 24 7 10 24 WARNING: Never open a fuse holder while it is under load. Electrical arcing and damage to the fuse holder will occur if a fuse holder is opened under load. PV String Fuses All SolarBOS disconnect combiner boxes ship with fuses installed according to the user s predetermined requirements. All fuses and connection points are electrically tested prior to shipment. SolarBOS maintains stock of common fuse sizes if replacements are necessary or spares desired. 9

Over-ride Switch The contactor combiner includes an over-ride switch assembly. An internal switch is connected to an external handle with clearly marked ON and OFF positions. External Handle The switch handle (located on the enclosure door) allows padlocking in the OFF position with the door closed. This feature can be used for Lock Out/Tag Out procedures. For commissioning and/or testing, it may be necessary to temporarily defeat the catch on the external handle with the handle in the ON position. With the switch on, the handle door interlock may be defeated with a tool to allow the door to be opened. The door interlock may be defeated in the ON position but reactivates automatically when the enclosure door is closed. See item 1 on Figure 4. Figure 4 Defeating the handle catch in the ON position WARNING: Only qualified personnel should perform any work within the contactor combiner box. 10

Combiner Box Torque Values BOX LUG OUTPUTS SMALL CONDUCTORS CONDUCTOR SIZE TORQUE ITEM TORQUE 1/0-2/0 180 in-lbs FUSEHOLDER/SURGE (TVSS) 22 in-lbs 3/0-4/0 250 in-lbs NEGATIVE/NEUTRAL INPUTS 25 in-lbs 250-350 325 in-lbs SMALL GROUND SCREW 25 in-lbs 400-600 375 in-lbs LARGE GROUND SCREW 50 in-lbs 700-800 500 in-lbs BOLTED CONNECTIONS & 900-1000 600 in-lbs COMPRESSION LUGS THREAD SOCKET TORQUE 1/4" 7/16" 120 in-lbs M8 13mm 220 in-lbs M10* 17mm 275 in-lbs M10 17mm 550 in-lbs *For Contactor Combiners M12 19mm 600 in-lbs 11