Getting started with

Similar documents
Micro Wireless Electricity Monitor

5 IN 1 JUMP START OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JS5IN1 PART NO: LS0810

Operating instructions. sonnenprotect for operators. KD-337 Part no Version X00.

362 Clamp Meter. Users Manual

JUMP STARTER OPERATION & MAINTENANCE INSTRUCTIONS MODEL NO: JSM350 PART NO: ORIGINAL INSTRUCTIONS LS1117-ISS 1

HALOGEN FLOODLIGHTS Models CHL1260C & 1260T Part Nos: &

instructions for roadstart units

SWING ARM MAGNIFYING LAMP MODEL NO: SAM170

SL2380. Installer s guide. Owner skit. Blind control device Battery module.

1 Plug one extender near your router 2 Plug one extender near your device 3 Connect your device

Rescue Pac. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference

OWNER S MANUAL Please read and understand all precautions prior to use.

Owner skit. Manuale per l installatore Installer s guide Installations- Anweisungen Notice installateur SL2380

ORIGINAL INSTRUCTIONS

Eazidraw Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

Please read and understand all precautions prior to use.

User Guide. Model No.: GDI-GFD7200

My Reserve 500 Install Guide

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

Pro Booster 802Li. Please read and fully understand the instructions in this manual before operation. Keep this manual safe for future reference.

28W WORK LAMP Model: CTL28 Part No:

JUMPSTART MODEL NO: JS1000, JS1010 & JS1224 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: , & GC0514

Adam Equipment DUNE DCT SERIES. (P.N. 9384, Revision B2, June 2013)

Eazipole Cordless. Installation & Set Up Instructions. Electric Blinds & Curtains

ELECTRIC CAR POLISHER

Warning: Electricity. Wear Protective Gloves

CONTENT 1 PICTURE GENERAL... 3

LEAD ACID BATTERY CHARGER

StarEye. 350 ma version. No control electronics on board

Owners Manual for TPMS plus GPS

Installing a Programmed Fronius SCERT in a Managed AC Coupled system

OPERATION & MAINTENANCE INSTRUCTIONS

Wallbox Commander. User Guide WBCM-UG-002-EN 1/11

Solo III display. Quick Reference Guide

INSP-3 Wiring Inspection Tester

i3000s/i2000 Flex AC Current Probe

OPERATION & MAINTENANCE INSTRUCTIONS

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

365 Detachable Jaw True-rms Clamp Meter

HIGH FREQUENCY AUTOMATIC BATTERY CHARGER

BATTERY STARTER/CHARGER MODEL NO: BC125, BC190

OPERATION & MAINTENANCE INSTRUCTIONS

Battery Charger JCB-FCH12Li

HOT WASHER MODEL NO: KING 125 OPERATION & MAINTENANCE INSTRUCTIONS PART NO: LS1009

Bosch Smart Home. Door/Window Contact Instruction Manual

BMW i. Freude am Fahren. BMW i Wallbox Plus. Owner's manual

ENERGY MANAGER. Installation Manual

2011 Ocean Signal Ltd

24V DC - 1/2 SQUARE DRIVE IMPACT WRENCH KIT

HD18F2M1.

Non-Contact Phase Rotation Tester

WELDING INVERTER. PEGAS 160 E Smart PEGAS 200 E Smart OPERATING MANUAL. ALFA IN a.s. PEGAS E Smart Manual EN 04

Contents. English 1. French 40. Spanish 81

Sinewave Inverters. SWING 150VA and 300VA. User s manual

BMW i. Freude am Fahren. BMW i Wallbox Plus. Instructions for use

323/324/325 Clamp Meter

LIGHTBOLT MAX EXTENDABLE WORK LIGHT INSTRUCTION MANUAL. Model No. 4063

EASY CHARGE Weather-resistant fixed mount Battery Charger

MODEL Nos: CVAC20SS CVAC25SS CVAC30SSR OPERATING & MAINTENANCE INSTRUCTIONS. Distributed by CLARKE International Ltd.

8-Bay Rapid Charger. for AA/AAA NiMH & NiCd Rechargeable Batteries. Owner's Manual. Please read before using this equipment.

JUMPSTART MODEL NO: JS900/JS910 OPERATING & MAINTENANCE INSTRUCTIONS PART NO: & GC10/16

SMA INTEGRATED STORAGE SYSTEM

The following lighting types are NOT compatible with the TT- 402Wireless Inline Dimmers:

PROFESSIONAL CORDLESS IMPACT SCREWDRIVER

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

Patron Call System. Scope s DataPage II Lite & NexCall Coaster. Operators/Installation Manual

Wireless Digital Room Thermostat with Night Set-Back

NANOPAC-300 & 500 Power Supply. Instruction manual NANOPAC-300 & NANOPAC-500

MANUAL. Protein skimmer with external pump. Protein skimmer with internal pump ZL-SKIMMER-MANUAL-V1.0

CORDLESS COMPRESSOR WITH SPOTLIGHT + JUMP START

Battery System User Manual for Panasonic LJ-SK56A BATTERY SYSTEM USER MANUAL FOR PANASONIC LJ-SK56A

USE AND CARE GUIDE DUALCHECK CIRCUIT TESTER

Electric Hi Lo Screen lift Trolley Mount 8960

RS1.V4 RS102.V3 RS103.V2 RS104.V2 RS105.V2

MANUAL BAT/48342 IMPORTANT NOTE : BEFORE FIRST USE CHARGE THE JUMP STARTER WITH THE SUPPLIED CHARGER FOR AT LEAST 12 HOURS.

Battery Charger JCB-FCH20LI2

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

Daylight Rechargeable Portable Light

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

WIRELESS TRI-JACK WIRELESS REMOTE KIT COMPONENTS LITERATURE NUMBER REV. C WARNING EXPLOSION WARNING PERSONAL INJURY & PROPERTY DAMAGE

T Series (N6052T) Solar Battery Hybrid System. Installation Manual Version 1.1

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

PV Master OPERATION MANUAL

OPERATING INSTRUCTION

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

SPECTRE DRONE USER MANUAL

Emergency Power Supply for the OMEGA ACTIVE-System. Operating Instructions

18V CORDLESS DRILL MODEL NO: CON18LiC

BATTERY BOOSTER/CHARGER MODEL NO: DIGICAR 600

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Installer Guide smart connect

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

18V CORDLESS STAPLER/NAILER

1200W INVERTER GENERATOR

OPERATING INSTRUCTIONS

Universal 8-Bay Charger. for AA/AAA/C/D/9 NiMH & NiCd Rechargeable Batteries. Owner's Manual

Transcription:

PART NO. CMA113 MADE IN CHINA 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp Getting started with Electricity consumption & Solar PV generation monitoring single phase, for homes fitted with Solar PV IN THE BOX: Transmitter unit 3 channel 2 x plug-in standard Sensor clamp (<10mm cable, <71A) x 2 3 x AA alkaline battery 2 Save Energy Limited 2014 1

Introduction This Electricity Transmitter is a part of the OWL Intuition range of cloud connected monitoring and control products. Its operation is dependant upon being paired to the broadband Internet connected Network OWL (supplied separately). This version of the Electricity Transmitter is designed for monitoring single phase electricity consumption and Solar PV generation. It is suitable for use in homes and some smaller light commercial premises. Access to both live and historic energy information collected by this Transmitter is via the OWL Intuition web dashboard, from any Internet connected computer anywhere in the World. iphone and Android smartphone apps are also available for free download. For details on using your new OWL Intuition-pv system, please download the Electricity Monitoring User Manual document by clicking on Manuals on the web dashboard (lower right). 2 2 Save Energy Limited 2014

Installation Instructions BEFORE YOU START - Determine PV System Type Intuition-pv will NOT work correctly unless the correct wiring configuration has been identified and the 2 or 3 Sensor clamps are correctly installed. Intuition-pv Type 1 (solar PV - Henley block) The standard Intuition-pv package is only suitable for a Type 1 wiring configuration where the PV generation feed is connected to the properties existing mains wiring via a Henley Junction Block. Please refer to wiring diagram on page 4 to identify if this installation is a Type 1 configuration. Intuition-pv Type 2 (solar PV - Consumer unit) If the PV generation feed is connected to the properties existing mains wiring via a circuit breaker or fuse within your main Consumer Unit / Fuse Box then this is a Type 2 wiring configuration. Please refer to wiring diagram on page 5 to identify if this installation is a Type 2 configuration. IMPORTANT: If you have a Type 2 wiring configuration you MUST also purchase a Y-Cable Pack (Part Number: TSE200-010). This includes a third Sensor clamp and a Y-Cable. 2 Save Energy Limited 2014 3

Type 1 Intuition-pv (solar PV - Henley block) Transmitter & Sensor Installation Transmitter Grid-tie Inverter DC Solar PV Array Utility Meter 230V AC 50Hz PV Generation Sensor Fuse Box / Consumer Unit Domestic Loads WARNING - RISK OF ELECTRICAL SHOCK - Please Refer to User Manual. Electricity Grid Henley Junction Block WARNING - RISK OF ELECTRICAL SHOCK - Please Refer to User Manual. Ring Mains, Lights, Cooker etc Consumption Sensor Normal Convention with Live cable to Consumer Unit being the right most cable connected to the Meter (Brown or Red normally covered with Grey sheath) 4 2 Save Energy Limited 2014

Type 2 Intuition-pv (solar PV - Consumer unit) Transmitter & Sensor Installation Transmitter PV Gen Sensor 1 Orientation of this clamp is not important Y-Cable 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp PART NO. CMA113 MADE IN CHINA Grid-tie Inverter 230V AC 50Hz DC PV Gen Sensor 2 Important: Orient this clamp so that the CE marking is facing the inverter Solar PV Array Domestic Loads Utility Meter 1. Measuring CAT II 2. Max. voltage 250V ~ 3. Max. current 71 Amp PART NO. CMA113 MADE IN CHINA Fuse Box / Consumer Unit Electricity Grid Grid Sensor Important: Orient this clamp so that the CE marking is facing WARNING - RISK OF ELECTRICAL SHOCK - Please Refer to User Manual. Y-Cable Pack also required Ring Mains, Lights, Cooker etc Normal Convention with Live cable to Consumer Unit being the right most cable connected to the Meter (Brown or Red normally covered with Grey sheath) 2 Save Energy Limited 2014 the grid supply 5

STEP ONE - Install Network OWL If you are adding PV monitoring to an existing Intuition installation then please jump to STEP THREE - Log in and follow Wizard. If this is a new Intuition installation then you will first need to install the Network OWL (supplied separately). For full details please refer to the Network OWL installation guide supplied with that product, however a summary of the steps are listed below: 1. Connect Ethernet cable between spare active LAN port on your broadband Internet router and the Network OWL. 2. Plug the power supply into the mains and insert the DC jack connector into the base of the Network OWL. 3. Wait until the green LED on the top of the Network OWL is flashing with a triple blip pattern. This should not normally take longer than 2 minutes. 4. Do NOT proceed to STEP TWO until this flashing pattern is observed. STEP TWO - Create Intuition online account If you are adding PV monitoring to an existing Intuition installation then please jump to STEP THREE - Log in and follow Wizard. If this is a new Intuition installation then you will first need to create a new OWL Intuition account. For full details please refer to the Network OWL installation guide supplied with that product, however a summary of the steps are listed below: 6 2 Save Energy Limited 2014

1. Using a web browser visit https://www.owlintuition.com 2. Click Create Account. 3. Check and confirm that the Network OWL is online. 4. Fill in the information requested. 5. Click Create Account button. 6. Ensure successful account creation completion message is displayed. STEP THREE - Log in and follow Wizard Log in to the OWL Intuition account with username and password. If this is a new system the installation & configuration Wizard will automatically open. For existing Intuition installations you should start the Wizard by clicking the Wizard menu bar option at the top of the screen. Select Electricity / Solar Monitoring from the drop down box. Click the Start button and follow the Wizard through these steps: Select Electricity Transmitter 2 Save Energy Limited 2014 7

type as CMR180i and click Next. Slide back cover off of the Transmitter and insert the batteries into the unit. Press the small Check button in the Transmitter battery compartment until the red LED on the front starts flashing. PART NO. CMR180i MADE IN CHINA PRESS CHECK BUTTON The Transmitter is now in Pairing / Check Mode and the red LED on the front will start flashing every 2 seconds (for 30 seconds). Click the Wizard Next button. IMPORTANT Pairing Notes: Please DO NOT remove the Transmitter batteries once fitted or the pairing will be lost. You can quickly check for correct pairing at any time by pressing the Transmitter Check button until the red LED starts flashing - if the Transmitter red LED and Network OWL blue LED flash within a fraction of a second of each other, they are correctly paired. When the Pairing Successful message is displayed in the Wizard click Next. Select Electricity Monitoring System type as either Intuition-pv Type 1 (Solar PV - Henley block) OR Intuition-pv Type 2 (Solar PV - Consumer unit) to suit the wiring configuration used by this installation (see page 3 for details) 8 2 Save Energy Limited 2014

and click Next. Adjust consumption Voltage and Power Factor settings to measured values if available. If in doubt leave the default values (Voltage = 230; Power Factor = 1.0) and click Next. Configure the Solar Settings (Generation) settings to measured values / current meter readings if available. If in doubt leave the default values (Voltage = 240; Power Factor = 1.0). Enter the PV System Rating (kw) and select the direction that the majority of the solar panels are facing then click Next. Ensure message Device successfully added to your Intuition system. is displayed. Click the Finish button. Unless you have further Intuition devices to install / configure then click the Finish button. Click the OK button to close the Wizard. The web dashboard will then automatically refresh itself and you should now have an Electricity and Solar widget within the web dashboard, although the live readings will be zero at this stage until the Sensors are correctly attached in the next step. 2 Save Energy Limited 2014 9

STEP FOUR - Install Transmitter and attach Sensors IMPORTANT: You must ensure that each Sensor is ONLY around the live core and NOT around a sheathed cable containing live, neutral and earth. The Sensors must be a loose fit onto the cables. After the Sensors have been installed, the Transmitter should be hung on the wall in a free area as far from large metal objects as possible. In the section BEFORE YOU START on page 3 you will have determined whether you are installing an Intuition-pv Type 1 (solar PV - Henley block) OR an Intuition-pv Type 2 (solar PV - Consumer unit) system. Please now follow the relevant sub-section below, referring to the diagrams on pages 4 and 5 as required. Intuition-pv Type 1 (solar PV - Henley block) Consumption Sensor - Locate the supply cables between the Henley block and consumer unit (fuse box). Using the latch, clamp the first Sensor around the insulated Live cable going into the consumer unit. Plug this Sensor into the Transmitter left hand socket. The orientation of this Sensor is not important. Generation Sensor - Locate the PV generated power cable between the Henley block and Generation meter / Inverter. Using the latch, clamp the second Sensor around the insulated Live cable going into the Henley Block. Plug this Sensor into the Transmitter centre socket. The orientation of this Sensor is not important. 10 2 Save Energy Limited 2014

Intuition-pv Type 2 (solar PV - Consumer unit) PV Generation Sensor 1 - Locate the PV generated power cable between the inverter and consumer unit (fuse box). Using the latch, clamp the first Sensor around the insulated Live cable going into the consumer unit. Plug this Sensor into the Transmitter centre socket. The orientation of this Sensor is not important. PV Generation Sensor 2 - For correct operation it is important that the CE mark on this Sensor is oriented to face the Inverter end of the cable. Taking this into account, using the latch, clamp this second Sensor around the same insulated Live cable that PV Generation Sensor 1 is attached to. Plug this Sensor into either of the arms of the Y-Cable. Grid Sensor - Locate the supply cables between your electricity meter and consumer unit (fuse box). For correct operation it is important that the CE mark on this Sensor is oriented to face the electricity meter end of the cable. Taking this into account, using the latch, clamp this third Sensor around the insulated Live cable going into the consumer unit. Plug this Sensor into the remaining arm of the Y-Cable. Y-Cable - With both Sensors attached, plug the Y-Cable into the Transmitter left-hand socket. Tip: Orient the Sensor clamps such that the CE mark faces the direction the power is coming from. 2 Save Energy Limited 2014 11

STEP FIVE - Log in to your OWL Intuition account If you are not already, please log in to your OWL Intuition account with your username and password at: https://www.owlintuition.com You should now have an Electricity and Solar widget within your web dashboard. If you watch these new widgets, you should see the live consumption and generation values updating every 12 to 60 seconds. Type 2 systems only - If when the Generation figure changes you see the Consumption figure change by a similar amount you need to reverse the direction the cable is going through Grid Sensor. Undo the Sensor latch, remove, twist 180 degrees and re-attach around the cable. If unclear please see web site Support for further information. Consumption Generation Check the signal strength of the radio signal between your Transmitter and Network OWL: If the signal strength is only 1 or 2 bars, to reduce the chance of intermittent / inconsistent data reception it is suggested that you reposition the Network OWL so that it is physically closer to the Transmitter. 12 2 Save Energy Limited 2014

Signal strength indicator Settings icon The Network OWL should ideally be hung on the wall in a free area as far from large metal objects as possible. Position the antenna in a vertical orientation. If necessary you can replace the Ethernet cable with a longer cable (up to 100 meters long). If installing a long Ethernet cable is a problem, you can use a Powerline Range Extender or Wireless Range Extender - please search for these common products online. Click on the Electricity widget Settings icon - here you can set details of your electricity tariff. 2 Save Energy Limited 2014 13

Click on the Solar widget Settings icon - here you can set details of your feed in / export tariff. For details on using your new OWL Intuition-pv system, please now download the Electricity Monitoring User Manual document by clicking on Manuals on the web dashboard (lower right). Please ensure you retain this document for future reference. 14 2 Save Energy Limited 2014

INFORMATION & TROUBLE SHOOTING TIPS Unless the Transmitter is in Check Mode, the red LED does not flash, in order to prolong battery life. Check that the blue LED on the Network OWL flashes at least every 12 seconds if the monitored electricity supply consumption is varying, or every 60 seconds when at a steady state. For wireless range testing you can make the Transmitter send its signal every 2 seconds (for 30 seconds) by pressing the Check button in the battery compartment for 10 seconds. The red LED will flash with each transmission, the Network OWL blue LED will flash to confirm the signal has been received. If the blue LED does not flash then the Transmitter signal is not being received or the Transmitter Pairing has been lost. On the web dashboard click on the Devices menu, then click on Electricity Transmitter. If the Last Reported time is greater than 60 seconds then it is likely the batteries have been removed from the Transmitter since pairing. Click on the Change Batteries button and follow the instructions provided. If necessary undo the Transmitter s Sensors and move it so it is close to the Network OWL. Repeat step above to confirm if radio range is an issue. Battery change - when the Transmitter batteries require replacement the battery icon on the Electricity widget will change to red. Use web dashboard Devices menu / Electricity Transmitter / Change Batteries feature to ensure that pairing is not lost. 2 Save Energy Limited 2014 15

SAFETY INFORMATION To ensure that you use your product safely and correctly please read the warnings & safety precautions below before installing your OWL Intuition Transmitter & Sensor. This product uses a Type C current Sensor. Do not apply around or remove from hazardous LIVE conductors. When fitting the Sensor if in any doubt always contact a qualified electrician. Do not immerse the unit in water or other liquids. If you spill liquid over it, dry it immediately with a soft cloth. Do not use or store the product in conditions that could adversely affect the product such as rain, snow, desert and magnetic fields. Do not subject the product to excessive force, shock, dust, temperature or humidity. Keep the product away from heat sources - radiators, stoves, heaters etc. Do not use the product in or near water or in high moisture areas such as bathrooms. Do not tamper with the product s internal components. This invalidates the warranty. Do not attempt to repair the product yourself. Contact the retailer or Customer Services if your product requires servicing. If the equipment is used in a manner not specified in this manual, the protection provided by the equipment may be impaired. Take care when handling all battery types. Batteries can cause injuries, burns or damage to property if they come into contact with conducting materials, heat, corrosive 16 2 Save Energy Limited 2014

materials or explosives. Remove the batteries before storing the product for extended periods. Only use fresh batteries. Do not mix new and old batteries. Do not dispose of old batteries as unsorted municipal waste, only do so in accordance with your local waste disposal regulations. When disposing of this product do so in accordance with your local waste disposal regulations. CARING FOR YOUR PRODUCT Before cleaning, disconnect the Sensor and remove the batteries from the Transmitter. Use a lightly dampened cloth. Do not use liquid or aerosol cleaning agents, benzene, thinners, abrasive or corrosive materials. Do not scratch hard objects against the product. Do not leave discharged batteries in the product. 2 Save Energy Limited 2014 17

SPECIFICATIONS Transmitter dimensions Sensor dimensions (max when closed) Radio frequency band Operating range Power source Operating temperature range Storage temperature range Relative humidity COMPLIANCE 64mm x 95mm x 40mm 50mm x 50mm x 30mm 433MHz unlicenced ISM band Up to 30m (in free space) 3 x 1.5V Alkaline AA batteries 0 C to +40 C -25 C to +65 C 25% to 95% non-condensing The CE marking certifies that this product meets the main requirements of the European Parliament and Council Directive 1999/5/EC. A copy of the signed and dated Declaration of Conformity is available on request. OWL Intuition products are manufactured to ISO-9001 Quality Assurance Standards. 18 2 Save Energy Limited 2014

WARRANTY INFORMATION 2 Save Energy Limited guarantees that OWL Intuition products will work for a minimum period of 24 months from date of purchase and that it will be free from defects in materials, workmanship or design. If during this limited 2 year period of guarantee, from date of purchase, you find that the equipment is not working properly, you may return it to us and we will replace, or, (at our discretion) repair it, free of charge. 2 Save Energy Limited will not accept any liability for defects arising from fair wear and tear, accidental or wilful damage, misuse or failure to follow product or safety instructions If you return any equipment as faulty, 2 Save Energy Limited reserves the right to test the equipment and if found to be in perfect working order, to return it to you. In this event, 2 Save Energy Limited reserves the right to charge for any testing or postage costs incurred. This does not affect your legal rights relating to equipment, which is faulty. Warranty conditions only apply where Proof of Purchase is provided. To return your OWL Intuition product please contact customer.services@theowl.com to report the issue and your reason for wishing to return your product. 2 Save Energy Limited will issue you an RMA number. You should ensure that the returned product is clearly marked with the issued RMA number. Once we have received the product and proof of purchase we will commence the returns process. 2 Save Energy Limited 2014 19

20