UMA Fiber Optic Modular Adapter System Flexibility in a 2-Piece Adapter System

Similar documents
S123 v2 Fusion Splicers Hand-Held Clad Alignment Fusion Splicer

LC Cable Assemblies. Fiber Optic Products Catalog. Product Facts. LC Cable Assembly. Hybrid LC-SC Cable Assembly

OFS 400A FIBER OPTIC INTERCONNECT Instruction Sheet UNIT (FOIU) Comcode INSTALLATION

Crimp & Cleave Termination Instructions

FC/APC Patchcord FC/APC. Insertion Loss(Reference plug) Insertion Loss (Random mated) Return Loss

S Ingle Mode Fiber Patch Cord and Pigtail (SC/APC, LC/APC)

Singlemode Fused Coupler LGX Module (832 Series)

OFS Fitel LST1U-072/7 and LSTLW Instruction Sheet (LaserWave) Fiber Optic Comcode: Termination Shelf Installation

This instruction sheet covers the installation of the Fiber Optic 200A Interconnection Unit, which includes LaserWave Applications.

IBER DISTRIBUTION FRAME (FDF) FOR EXCHANGE SIZE 900MM x 2200MM x 300 MM

EPA10 DOC Inlet Pressure Sensor November Removal of the EPA10 Diesel Oxidation Catalyst Inlet Pressure Sensor. without Sensor Box

INSTALLATION INSTRUCTIONS

MTP Loose Tube Trunk Assemblies. Features. Applications.

MIC Unitized Plenum Cables, Fibers

FITEL S178 Ver.2 Hand-held Core-Alignment Fusion Splicer

ModBox Series SMPTE 304M Modular Rack System Patent Pending 6/8/2009

Illustrated Parts List Pressure Washer / Lavadora de Presión

INSTALLATION INSTRUCTIONS

Illustrated Parts List Pressure Washer / Lavadora de Presión

Crimp & Cleave Termination Instructions

Avionics Optical Cables

Instructions for Use - Opt-X 1000i Enclosure

SFP Fiber Optic Transceivers

MIL-PRF type fiber optic termini F722 - F724

Features and Benefits

IPD Products for CATERPILLAR 3126 ENGINES

MIC Plenum Cables, 2-24 Fibers

ME Switchgear with Vacuum Circuit Breaker and Auto-jet II Switch with Ground Position

Application Specification Circular Plastic Connector (CPC) Series 45 System 05 AUG 14 Rev D

Illustrated Parts List. Pressure Washer / Lavadora de Presión

C ole Instrument Corporation is proud to offer a rotary switch

SAFRAN ELECTRONICS & DEFENSE AVIONICS USA LLC. Series 90 Tellite Switch

Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF and ZDF

ipatch Ready Upgrade Kit for SYSTIMAX 360 Fiber Shelves Instructions

LX2 High Density LGX 4U Patch Panel

FiberConnect Bare Fiber Adapter. nrit

High-Dynamic-Range Power Sensors Models 2101 & 2103

Rated voltage (V) Current (A) Stranded wire. Solid wire A.D.O. (AWG)

Illustrated Parts List. Pressure Washer / Lavadora de Presión

LX2 High Density LGX 4U Patch Panel

Features and Benefits

XB IEC Terminal Blocks. Screw Type Insulation Displacement Connection Type

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, LC InstaPATCH Distribution Panel Instructions

icon User s manual Table of Contents section 6 icon module installation and removal

Amphenol 348 Series High Density Connectors

Illustrated Parts List

ezspan ADSS Short Span All-Dielectric Self-Support Loose Tube Cable

Illustrated Parts List. Pressure Washer / Lavadora de Presión

Plug & Play AnyLAN Systems

40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly

Fiber Optic, Breakout cable, tight buffered, 900 microns

PDA2300. Economical Plastic NEMA 4X Enclosures for 1/8 DIN Digital Panel Meters FEATURES OVERVIEW

6/2 ways/positions flow diverters L (VS120-VS125-VS129)

Illustrated Parts List. Pressure Washer / Lavadora de Presión

CVH103P. Check Valve Series CVH103P. Technical Information. General Description

LSS1U-144/7 FIBER OPTIC SPLICE SHELF INSTALLATION GENERAL CUSTOMER SERVICES REFERENCES TOOLS REQUIRED

Reproduction. Not for. Parts Manual. Tornado Series Straight Shaft String Trimmer. Models

ILL. 1. Horizontal. supply air cover panel shipped on HVAC unit. Access door/ panel

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Illustrated Parts List Pressure Washer / Lavadora de Presión. Pressure Washer

JOHN DEERE AG & TURF DIVISION

Mfg. No: ,100 PSI Briggs & Stratton

INSTALLATION INSTRUCTIONS

Electronic Circuit Breaker ESS20

Panduit PreConfigured ZDF48-RA Industrial Distribution Frame (IDF) Installation Instructions

155 CARTRIDGE SINGLE SEAL

Illustrated Parts List. Pressure Washer / Lavadora de Presión

Masoneilan * Lo-dB Cartridges and Expansion Plates

Illustrated Parts List. Pressure Washer / Lavadora de Presión

DSL-220 MkIII Single Pass Opacity Monitor Measures 0-100% Opacity

Fiber Splice Panel Rack Mount User Manual

F485 Communications Converter

RF COAXIAL CONNECTORS, TYPE SMA, 50 OHMS (FEMALE CONTACT) ESCC Detail Specification No. 3402/002

TE Connectivity DEUTSCH Single Module EN4165 connectors

Illustrated Parts List Portable Generator

ArcTite. single path to optimal performance. Ultra-low profile bends

MMC RTX series EN3716

SNP-8 Series Single mode FC CONNECTOR PLUG - for Angled-PC, Conical Shape -

Directional valve elements L808103P (ED4-PT1) of Tank unloaded excess flow. RE Edition: Replaces:

Fiber Cables & Hardware

BRCP6SM ITT. CentriPro. 6-10" Submersible Motors. For 6" and Larger Deep Well Pumps. Engineered for life

Illustrated Parts List. Pressure Washer / Lavadora de Presión

Get Fiber Smart. Part 1 : Best Practices in Enterprise Fiber Connectivity. Part 3: Best Practices in Tier2 Enterprise Fiber Link Testing and

Construction 2-24 tightly buffered fibres 900 m 50 m. colour code 1 Red 13 Yellow w/mark every 70 mm 2 Green 14 White w/mark every 70 mm 3 Blue 15 Gre

Illustrated Parts List. Pressure Washer / Lavadora de Presión

Illustrated Parts List. Reproduction MODEL Not for. 20,000 Watt Home Generator System

Illustrated Parts List. Inverter Generator

Alter QHE Lighting Systems

Illustrated Parts List. Inverter Generator

Installation and Maintenance Instructions Falk Wrapflex (Page 1 of 7) 1. General Information. 2. Safety and Advice Hints DANGER! Type 10R.

Deuterium and Tungsten-Halogen Hybrid Light Source. Operation Manual

Illustrated Parts List. Portable Generator

SYSTIMAX 360 ipatch G2 Fiber Ultra High Density (UHD) Shelf, MPO Distribution Panel Instructions

Floor diffusers. The art of handling air. Type FB. In aluminium and plastic

Illustrated Parts List Pressure Washer / Lavadora de Presión. Pressure Washer

Illustrated Parts List Pressure Washer / Lavadora de Presión. Pressure Washer

ATN3580 Series: Fixed Attenuator Pads

RP SMA Male Connector Crimp/Solder Attachment for RG174, RG316, RG188, PE-B100, PE-C100, inch, LMR-100

Introduction. Pressed Shaft Flowmeter. Flowmeter Service Kits. Disassembly. Idler Shaft Removal

FIBER INSIDE PLANT. Rack Mount Panels Optical Modules Cable Assemblies Components

Transcription:

UMA Fiber Optic Modular Adapter System Flexibility in a 2-Piece Adapter System Universal Modular Adapter Family (2.5 mm Base) Features Two-piece design Single-mode applications SC, ST, and LC Clothespin Bases SC, ST, FC, and LC Clothespin Straight Caps LC Base and LC Cap Benefits Allows cleaning the behind-thewall connector from the front of the panel Customers can choose the type of connectors Allows OEMs to standardize on a single connector type while allowing service provider customers a choice of connector options Easy migration to new connector types Product Description The Universal Modular Adapter (UMA) System is a two-piece, split adapter system that facilitates standardized equipment design and network configuration. The UMA base mounts in the faceplate adapter opening and accommodates the connector behind the faceplate. The UMA cap contains the alignment sleeve and supports the jumper connector. Universal Modular Adapter Family (LC Clothespin Base and Cap) Applications Optical networking equipment (longhaul, metro, local access, enterprise) Fiber optic distribution systems (LGX distributing frames, building entrance equipment) Original Equipment Manufacturer (OEM) customers can choose the connector style that best fits their requirement behind the faceplate while allowing service provider customers the flexibility to choose a different connector type. Service providers can simplify their migration path to new connector types by adopting the UMA system in their fiber management hardware. Attenuation is easily accomplished by replacing the standard 0 db cap with an attenuated cap of the desired value. The unique split design allows easy access to the rear connector for cleaning, and eliminates the additional jumper protrusion from the panel caused when using typical build-on attenuators. www.ofsoptics.com

UMA Fiber Optic Modular Adapter System Adapters The SC, ST, FC, and LC connectors are currently the most popular single-fiber connections in the communications industry. With the introduction of new hybrid adapter caps (SFF to 2.5 mm), the UMA system allows mating of different connector designs. The UMA Base is mounted into a panel cutout and serves as the connector port behind the faceplate. The UMA Cap contains the alignment sleeve and serves as the mating connector port. The cap is attached to the base through a mechanical latching arrangement and together form the Universal Modular Adapter. The LC UMA Family includ es two different designs: an LC clothespin base that mates only to an LC clothespin cap, and a new LC base that fits into a standard SC cutout. Hybrid UMA caps provide new functionality, allowing users to mate SFF LC jumpers to existing ST and SC bases, and SC jumpers to the new LC base. The hybrid sleeve feature allows mating of connectors with different ferrule diameters. 2.5 mm UMA Base Modular Adapter Ordering Information Description Product Code Flange Connector Used With ST Base A3002 106 709 140 Threaded-Panel ST opening ST A3060, A3070, A3080, FSAHS2-LC SC Base A3003 106 750 763 Clip-Panel SC opening SC A3060, A3070, A3080 FSAHS2-LC SC Cap A3060 106 708 951 SC A3002, A3003 ST Cap A3070 106 795 354 ST A3002, A3003 FC Cap A3080 106 795 404 FC A3002, A3003 1.25 mm LC Clothespin Base Modular Adapter Ordering Information Description Product Code Flange Connector Used With LC Base Clothespin A1LCS-BASE 108 265 950 Clip-Panel LC Clothespin LC A1LCS-CAP LC Cap Clothespin A1LCS 108 388 117 LC A1LCS-BASE www.ofsoptics.com

UMA Fiber Optic Modular Adapter System 9.60 ± 0.08 (.3780 ±.0031) Ø 9.80 ± 0.13 (.3858 ±.0051) 8.00 ± 0.10 (.3150 ±.0039) 1.52 (.0600) (min) 1.70 (.0670) (max) 7.20 ± 0.20 [.2835 ±.0079] 4 x R 0.20 [.0079] Max Typical 13.10 ± 0.08 (.5157 ±.0031) 18.20 ± 0.20 [.7165 ±.0079] LC Panel Mounting Hole Panel opening for SC Base 4 x R 0.40 (.0157) ST Panel Mounting Hole Panel opening for ST Base Panel opening for LC Clothespin Base SC Panel Mounting Hole SC, ST and LC Mounting Hole Dimensions (dimensions in mm (inches)) Hybrid vs. Standard UMA Caps Distinguishing Differences Note: Hybrid UMA caps (1.25 mm SFF to 2.5 mm ferrule) are distinguished from standard UMA caps (1.25 mm SFF to 1.25 mm SFF ferrule or 2.5 mm to 2.5 mm ferrule) by a white sleeve housing, providing easy identification in the field. Cap Description Product Code Sleeve Housing Color Used With Base Type SC Cap A3060 106 708 951 Blue A3002, A3003 www.ofsoptics.com

Install UMA Fiber Optic Modular Adapter System Remove Base and Cap Installation A3060SC Cap (dimensions in mm) A3080FC Cap (dimensions in mm) A3002ST Base (dimensions in mm) A3070ST Cap (dimensions in inches) [(dimensions in mm)] A3003SC Base (dimensions in inches) [(dimensions in mm)] A1LCS Assembly dimensions in mm [dimensions in inches]

UMA Fiber Optic Modular Adapter System Attenuator Identification Description Product Code Connector Color Used With LC Attenuator AALCS-xx.x LC Yellow A1LCS Base SC Attenuator ASCS-xx.x SC Light Green A3003SC Base A3002ST Base ST Attenuator ASTS-xx.x ST Green A3003SC Base A3002ST Base FC Attenuator AFCS-xx.x FC Light Green A3003SC Base A3002ST Base Attenuator Specifications ASCS, AFCS, ASTS, AALCS Series UMA Attenuator Caps Characteristic ASCS, AFCS, ASTS AALCS (Clothespin) Physical Split Adapter Cap Split Adapter Cap Color Green Yellow Transmission Single-mode Single-mode Nominal Attenuation @ 1550 nm See Table 2 See Table 2 Maximum Spectral Attenuation Variation (1530 to 1570 nm) 0.0125 times the nominal loss @ 1550 nm 0.0125 times the nominal loss @ 1550 nm Attenuation Tolerance See Table 3 See Table 3 Maximum Incident Optical Power Handling Capability 23 dbm 23 dbm Reflectance Typically -34 db Typically -34 db Operating Temperature -40 to 75 ºC -40 to 75 ºC Matings over Life 200 200 Attenuator used only with base: A3002 ST Base, A3003 SC Base A1LCS Base (Clothespin) Note: Nominal Attenuation Value is printed on visible part of body

ST UMA Single-Mode Attenuator Caps- Specifications and Ordering Information Attenuator Caps Used With: A3002, A3003 Maximum Reflectance: -30 db Product Code Attenuation db Tolerance at 1550 nm ± db Color: Green ASTS01.0 1.3 0.25 108 572 199 ASTS01.5 1.5 0.25 109 020 297 ASTS02.0 2.0 0.25 108 572 207 ASTS02.5 2.5 0.25 109 020 248 ASTS03.0 3.0 0.25 108 053 059 ASTS03.5 3.5 0.25 108 053 067 ASTS04.0 4.0 0.25 108 053 075 ASTS04.5 4.5 0.25 108 053 083 ASTS05.0 5.0 0.25 108 053 091 ASTS05.5 5.5 0.25 108 053 109 ASTS06.0 6.0 0.25 108 053 117 ASTS06.5 6.5 0.25 108 053 125 ASTS07.0 7.0 0.25 108 053 133 ASTS07.5 7.5 0.25 108 053 141 ASTS08.0 8.0 0.25 108 053 158 ASTS08.5 8.5 0.25 108 053 166 ASTS09.0 9.0 0.25 108 053 174 ASTS09.5 9.5 0.25 108 053 182 ASTS10.0 10.0 0.25 108 053 190 ASTS11.0 11.0 0.5 108 053 208 ASTS12.0 12.0 0.5 108 053 216 ASTS13.0 13.0 0.5 108 053 224 ASTS14.0 14.0 0.5 108 053 232 ASTS15.0 15.0 0.5 108 053 240 ASTS16.0 16.0 0.5 108 053 257 ASTS18.0 18.0 1.0 108 053 265 ASTS20.0 20.0 2.0 108 053 273 SC UMA Single-Mode Attenuator Caps- Specifications and Ordering Information Attenuator Caps Used With: A3002, A3003 Maximum Reflectance: -30 db Product Code Attenuation db Tolerance at 1550 nm ± db Color: Light Green ASCS01.0 1.3 0.25 108 538 760 ASCS01.5 1.5 0.25 109 020 271 ASCS02.0 2.0 0.25 108 538 778 ASCS02.5 2.5 0.25 109 020 214 ASCS03.0 3.0 0.25 108 314 469 ASCS03.5 3.5 0.25 108 314 477 ASCS04.0 4.0 0.25 108 314 485 ASCS04.5 4.5 0.25 108 314 493 ASCS05.0 5.0 0.25 108 314 501 ASCS05.5 5.5 0.25 108 314 519 ASCS06.0 6.0 0.25 108 314 527 ASCS06.5 6.5 0.25 108 314 535 ASCS07.0 7.0 0.25 108 314 543 ASCS07.5 7.5 0.25 108 314 550 ASCS08.0 8.0 0.25 108 314 568 ASCS08.5 8.5 0.25 108 314 576 ASCS09.0 9.0 0.25 108 314 584 ASCS09.5 9.5 0.25 108 314 592 ASCS10.0 10.0 0.25 108 314 600 ASCS11.0 11.0 0.5 108 440 496 ASCS12.0 12.0 0.5 108 440 504 ASCS13.0 13.0 0.5 108 440 512 ASCS14.0 14.0 0.5 108 440 520 ASCS15.0 15.0 0.5 108 440 538 ASCS16.0 16.0 0.5 108 440 546 ASCS18.0 18.0 1.0 108 440 553 ASCS20.0 20.0 2.0 108 440 561

LC UMA Single-Mode Attenuator Caps Specifications and Ordering Information Attenuator Caps Used With: A1LC-BASE Maximum Reflectance: -30 db Product Code Attenuation db Tolerance at 1550 nm ± db Color: Yellow AALCS00.5 0.5 0.25 108 355 363 AALCS01.0 1.0 0.25 108 355 371 AALCS01.5 1.5 0.25 108 355 389 AALCS02.0 2.0 0.25 108 349 457 AALCS02.5 2.5 0.25 108 349 440 AALCS03.0 3.0 0.25 108 288 481 AALCS03.5 3.5 0.25 108 288 440 AALCS04.0 4.0 0.25 108 357 963 AALCS04.5 4.5 0.25 108 357 971 AALCS05.0 5.0 0.25 108 288 473 AALCS05.5 5.5 0.25 108 357 989 AALCS06.0 6.0 0.25 108 349 432 AALCS06.5 6.5 0.25 108 357 997 AALCS07.0 7.0 0.25 108 288 465 AALCS07.5 7.5 0.25 108 358 003 AALCS08.0 8.0 0.25 108 358 011 AALCS08.5 8.5 0.25 108 358 029 AALCS09.0 9.0 0.25 108 358 037 AALCS09.5 9.5 0.25 108 358 045 AALCS10.0 10.0 0.25 108 288 457 AALCS10.5 10.5 0.25 108 358 060 AALCS11.0 11.0 0.50 108 358 078 AALCS11.5 11.5 0.50 108 358 086 AALCS12.0 12.0 0.50 108 358 094 AALCS12.5 12.5 0.50 108 358 110 AALCS13.0 13.0 0.50 108 358 128 AALCS13.5 13.5 0.50 108 358 136 AALCS14.0 14.0 0.50 108 358 144 AALCS14.5 14.5 0.50 108 358 151 AALCS15.0 15.0 0.50 108 358 169 AALCS16.0 16.0 0.50 108 358 177 AALCS17.0 17.0 0.50 108 358 185 AALCS18.0 18.0 0.50 108 358 193 AALCS19.0 19.0 0.50 108 358 201 AALCS20.0 20.0 0.50 108 358 219 FC UMA Single-Mode Attenuator Caps Specifications and Ordering Information Attenuator Caps Used With: A3002, A3003 Maximum Reflectance: -30 db Product Code Attenuation db Tolerance at 1550 nm ± db Color: Light Green AFCS01.3 1.3 0.25 108 385 493 AFCS01.5 1.5 0.25 109 020 255 AFCS02.0 2.0 0.25 108 385 501 AFCS02.5 2.5 0.25 109 020 230 AFCS03.0 3.0 0.25 108 107 053 AFCS03.5 3.5 0.25 108 107 061 AFCS04.0 4.0 0.25 108 107 079 AFCS04.5 4.5 0.25 108 107 087 AFCS05.0 5.0 0.25 108 107 095 AFCS05.5 5.5 0.25 108 107 103 AFCS06.0 6.0 0.25 108 107 111 AFCS06.5 6.5 0.25 108 107 129 AFCS07.0 7.0 0.25 108 107 137 AFCS07.5 7.5 0.25 108 107 145 AFCS08.0 8.0 0.25 108 107 152 AFCS08.5 8.5 0.25 108 107 160 AFCS09.0 9.0 0.25 108 107 178 AFCS09.5 9.5 0.25 108 107 186 AFCS10.0 10.0 0.25 108 107 194 AFCS11.0 11 0.5 108 107 202 AFCS12.0 12 0.5 108 107 210 AFCS13.0 13 0.5 108 107 228 AFCS14.0 14 0.5 108 107 236 AFCS15.0 15 0.5 108 107 244 AFCS16.0 16 1.0 108 107 251 AFCS20.0 20 2.0 108 107 277

UMA Fiber Optic Modular Adapter System For additional information please contact your sales representative. You can also visit our website at www.ofsoptics.com or call 1-888-fiberhelp (1-888-342-3743) USA or 1-770-798-5555 outside the USA. Copyright 2017 OFS Fitel, LLC. All rights reserved, printed in USA. OFS Marketing Communications DOC: fap-147 Date: 07/17 LGX is a registered trademark of OFS Fitel, LLC. OFS reserves the right to make changes to the prices and product(s) described in this document at any time without notice. This document is for informational purposes only and is not intended to modify or supplement any OFS warranties or specifications relating to any of its products or services.