LST SWITCHGEA. Motor Starters. Type MN. . Direct-On-Line Starters. Star-Delta Starters LARSEN & TOUBRO LIMITED. Its all about Imagineering TM

Similar documents
HRC Fuse-links Bolted Type HG 2 A - 32 A HQ 2 A A

Switch-Disconnector-Fuse HRC Fuse-links Bolted Type

ML 1.5 SS91851 ML 2 SS A 25 A 40 A 13.5 A 17 A 37 A 37 A. 6.3 A 15.5 A 15.5 A 12.5 A 23 A 23 A 19 A 830 V 415 V 500 V 3 kvar 120 A

Energy Saving HRC Fuse-Links


Energy Saving HRC Fuse-Links

Moulded Case Circuit Breakers New DU Series 20 A to 250 A

About us. Switchgear Factory, Mumbai

Switch-Disconnector-Fuse Switch-Disconnector Type FN

INDEX. Offerings & Compositions. Starters for Agricultural Pumps M-POWER. Submersible Pump Controllers. MK1 Starters 4. MU / MB Starters 6

Dazzle. Designed to. Inspired by the beauty of India

INDEX. Offerings & Compositions. Starters for Agricultural Pumps M-POWER. Submersible Pump Controllers. MK1 Starters. MU / MB Starters.

Reactive Power Management Products

About us. L&T now introduces compact range of 'Load Break Isolators' to suit the needs of Isolation for every safety needs. Switchgear Factory, Mumbai

Ordering Catalogue for Agricultural Standard Products

On Load Changeover Switches

Maximum Retail Prices

INDEX. Starters for Agricultural Pumps. MU - Automatic DOL Starters. Submersible Pump Controllers

Onload Changeover Switch. A Spectrum of Benefits...

SUPERNOVA Series. L&T's Range of Soft Starters

Mining made simple. No drilling. No blasting.

INDEX. Offerings & Compositions 1. MK1 Starters 4. MK2 Starters 6. i-protector 7. LTLK MCB with K-Curve 8 M-POWER+ 9. MU - Automatic DOL Starter 9

Onload Changeover Switch-Disconnectors

Switch-Disconnector-Fuse Switch-Disconnector Type FN

L&T SWITCHGEAR S A F E & S U R E. Moulded Case Circuit Breakers

Henikwon Busduct Systems Power Delivery Systems to Match Every Need

PC HP 12,600 kg 0.64 M3 (SAE) Construction Equipment Business L&T-Komatsu Limited

Moulded Case Circuit Breakers

AC Inverter Drives. For selection and product demonstration, please contact any of our branch offices listed below:

Motor Protection Circuit Breaker

The New 1000 Series AC Drives

DU Range of Moulded Case Circuit Breakers

Single Phase Submersible Pump Starters

Catalog. Low voltage General performance IE3 efficiency cast iron motors

About us. Switchgear Factory, Mumbai

Record SL. Moulded Case Circuit Breaker

Range : 7.5kW to 630/800kW

DRX. MCCBs for residential and commercial SYSTEMS FOR ELECTRICAL INSTALLATIONS & INFORMATION NETWORKS.

Spectronic-SP Air Circuit Breaker

Motor Protection Circuit Breakers

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Quality Products, Prompt Service, Trustful Relationships.

Starters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.

Range of Starters... for Every Need CITATION STARTERS

Flame Proof Motors For Hazardous Environment JHX

Spectra SP. Range of SD & SDF 32A to 800A

Automatic Star Delta Starters IEC : 2012 Compliant Direct-on-Line Starters ISI Marked-BIS Approved

01 RX3 2014_Cover-Front.pdf 1 6/24/ :08:02 PM

Infra Products. Infra Products

Bistable Relay. Types PSU6n, PSU14n.

Auxiliary Relay. Type RXP8n, RXPQ8n

e LARSEN & 70UBRO S '2000 AC Drive > High on intelligence big on reliability ., -mnm; SdOOO L&T SWITCH-I

The most widely used motors from the world leaders

C O M M E R C I A L D E C O R A T I V E L I G H T I N G

Energy Efficient 3 Phase LV Induction Motors

VACUUM PUMP. Material of Construction: Applications:

Spectronic SP Air Circuit Breaker. Protecting people, property & productivity

Auxiliary Relay. Type CV2

A9K. MCB, RCCB, Isolator

Integrated water management solutions

BCH CITATION STARTERS

NATIONAL HOUSING BANK. Press Release

CV Points Required. Economy Premium Economy Business

LABOUR CHARGES - BODYPAINT JOBS. Applicable for Group I+ Cities New GenVerna (HCi)

Smart. Shiny. Solar Powered. All-in-One. Solar Street Light

Non Return Valve Swing Check

Price List. Power Factor. With effect from June 15, Correction Products. With effect from January 03, 2012

ADS7 AC Contactor Starters

ADS8 IP54 Direct-On-Line Starter Technical Focus. Replaces ADS7 Rated up to 9kW

Energy Efficient 3 Phase

Manual changeover switches & Automatic transfer switches

Catalog. Classiq range Wiring accessories

Motor Starters. Star-Delta Starters Open Type 86. Star-Delta Starters Enclosed 88 Enclosure for Star-Delta Starters 88.

Inverse-Time Overcurrent & E/F Relays. Type ICM 21, ICM 21B

The new-age sustainable solution

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

ACX 750. Hydraulic Crawler Crane 75 tons Capacity. High performance rough terrain and rugged crawler crane.

Complete protection made easy. Datasheet. hrc fuses BS TYPE

SPnorm & SPbloc Self Priming Centrifugal Pumps

DC MOTORS. Crompton Greaves EVERYDAY SOLUTIONS

Auxiliary Relay. Type P8n, PQ8n, PN8n

WORM GEARS STIRRER UNITS

LET THE SUN POWER YOUR HOME

Capacity : 5 tons Engine Power : 79 bhp. High Performance & rugged Forklift Trucks.

Price list 03/2018. w.e.f. April 1, 2018

Young energy gives you more air delivery

Moulded Case Circuit Breakers

JFB 15 / 20 / 25 / 30 Josts Electric Counterbalance Trucks (Capacity 1500 / 2000 / 2500 / 3000 Kg)

Metal Clad VCBs ~ Mk1

Indoor Metal Clad Switchgear Type:Cubicle VHA 36 SF6 Circuit Breaker HPA 36 Rated Voltage: ABB Power Distribution

Open Chassis Star-Delta Starter User Guide

EVERY DRILL DIESEL ENGINES FOR COMPRESSOR APPLICATIONS. - Pdf manuals & parts catalogs library

KEOR HPE UPS. 3 PHASE UPS from 60 to 300 kw

Bollards. Our Strengths are: Engineering Expertise Innovative Design Simplified installation Anti-Debris System Performance Safety Maintenance

Kare Zindagi Instant Start

Goldline Miniature Circuit Breakers

INTERNATIONAL FREIGHT

Meeting with Commissioner, Kendriya Vidyalaya Sangathan (KVS) New Delhi 11 April 2016

LV- Power Quality Products and Systems

CI-TI Contactors and Motor Starters Type CI 6-50

Transcription:

LST SWITCHGEA Motor Starters Type MN. Direct-On-Line Starters. Star-Delta Starters LARSEN & TOUBRO LIMITED Its all about Imagineering TM

Larsen & Toubro Limited, India's largest manufacturer of low voltage switchgear products introduces the new MN range of starters. These starters are available in Direct-On-Line (DOL) and Star-Delta versions. This range represents the culmination of intensive R&D and extensive field trials. MN starters, comprising MN contactors and MN relays, provide Overload and Single phasing protection to your motors. MN starter family conforms to IS13947-4, IEC 60947-4 Starter Range

Sal ;en* Features. Conform to IS 13947 (Part 4) & IEC 60947-4. Built-in single phasing protection. In Star Delta Starters, Star contactor has same rating as Hold-on & Delta. Suitable for Industrial & Rural applications. Terminal block for ease of termination. Starter enclosure with IP 54 of protection Ap"lications MN starters are available in following versions: Direct-On-Line starter Semi automatic Star-Delta, starter (SASD). Fully automatic Star-Delta, starter () All MN DOL & Star-Delta starters are suitable for 3-Phase Squirrel Cage motors. MN DOL starters are available in following ratings: MN 16 DOL-upto 10 HP (7.5kW). MN 25 DOL-upto 15 HP (11 kw). MN 32 DOL-upto 20 HP (15kW). MN 45 DOL-upto 30 HP (22.5kW). MN 65 DOL-upto 45 HP (33.5kW) MN Star-Delta starters are available in following ratings:. MN 16 Star-Delta-upto 15 HP (11 kw). MN 25 Star-Delta-upto 25 HP (18.5kW). MN 32 Star-Delta-upto 35 HP (26kW). MN 45 Star-Delta-upto 50 HP (37.5kW). MN 65 Star-Delta-upto 75 HP (55kW). MN 80 Star-Delta-upto 90 HP (67.5kW). MN 110 Star-Delta-upto 125 HP (90kW). MN 140 Star-Delta-upto 175 HP (130kW) MN 45, MN 65, MN 80, MN 110 & MN 140 Star-Delta starters are available only in version. Construction MN starters consist of MNX contactors & MN relays. The relay is directly mounted on the contactor. The colour of the sheet steel enclosure is two-toned. The box is powder coated and gray in colour. The cover is powder coated with ivory colour. The push button is flush mounted in an enclosure cover, which has been given an altogether `new look'. Operational Details Relay Setting A screwdriver is used to set the relay indicator (which is on the dial) to the full load current setting. This ensures optimum protection under Overload and Single Phasing of the motor. In case of Star-Delta Starters, the relay must be set at the values In /j (0.58 In) as given in the selection table, since the connected relay carries only the phase current in Motors having Delta connected winding. MN DOL starters. MN 16, 25, 32, 45, 65 DOL starters incorporate type MNX contactors. MN 16, 25, 32 DOL starters incorporate MN 2 relays. MN 45, 65 DOL starters incorporate MN 5 relays. MN Star-Delta Starters MN Star-Delta starters are available in semi automatic and fully automatic versions. MN 16, 25, 32, 45, 65, 80, 110, 140 Star-Delta starters incorporate type MNX contactors. MN 16, 25, 32, Star-Delta starters incorporate MN 2 relays. MN 45, 65, 80, 110, Star-Delta starters incorporate MN 5 relays. MN 140 Star-Delta starters incorporate MN 12L relays. In case of SASD Starters, the motor gets connected in Star connection when the green button is pressed, after releasing the green button motor gets connected in Delta connection. The button must be released only when the motor reaches its normal speed. In case of Starter, motor gets connected in Star connection, when the green button is pressed. An electronic timer automatically performs the changeover function from Star to Delta. 1

Different sized holes with grommets at top & bottom for various cable sizes IP54 Protection class of enclosure makes it suitable for industrial and rural applications. Earthing screw with proper marking Two-tone colour combinations with box in steel gray & cover in ivory Better corrosion resistance through powder coated enclosure Flush-mounted push buttons. Single Phasing Protection MN relays having phase failure sensitive tripping mechanism provides reliable protection against Single Phasing & Overload conditions. MN relays are compensated for variation in ambient temperature from -5 C to 55 C. IP 54 degree of protection Corrosion resistant powder coated enclosure with IP/54 protection class makes MN starters most suitable for chemical factories, polluted industrial and dusty agricultural environment. Terminal Block MN Star-Delta starters are provided with terminal block with proper terminal marking for ease of wiring. Terminal block can accommodate both aluminium & copper cables. Features & Benefits Base Plate Mounting MN Star-Delta starters are mounted on base plate that can absorb vibrations and it makes MN starters maintenance friendly. Electronic Timer MN Fully Automatic Star-Delta starters are provided with Electronic Timer for high repeat accuracy. Trip Test Facility This facility enables the user to manually check the operation of the trip mechanism. Move the trip slide in the direction shown on the relay. The relay trips with an audible 'Click' sound, indicating that the trip mechanism is in good working order. Off / Reset Push-Button The relay will trip in case of overloads or single phasing conditions. Simultaneously 'Alarm Contact' (97-98) will close. The motor cannot be restarted until the relay has been reset. To reset the relay, allow the bimetals to cool down sufficiently & push this button to reset the trip contact (95-96). If the relay is in reset condition, pressing this push-button will open 'Trip Contact'. But now the alarm contact will not close. This indicates healthy operation of the relay mechanism. The trip contact will again close when this button is released. Auto-Manual Reset Switch There are two modes of reset available : Manual and Auto. By default the relay is in the Manual reset mode and can be converted to Auto reset mode by moving the switch to Auto position marked on the label. 2

Type Maximum Motor Rating at 415V, 3 50Hz Chart for MN DOL starers Approx. Full Load Current In HP KW (A) Relay Range ( A) Relay Contactor Recommended Back-up HRC Fuse Type Rating (A) Switch Disconnector Fuse Unit 2 1.5 3.5 3-5 HF 16 FN32 2.5 1.8 4.8 3-5 HF 16 FN32 3 2.2 5 4.5-7.5 HF 16 FN32 MN 16 4 3 6.2 4.5-7.5 HF 20 FN 32 MN 2 MNX 18 DOL 5 3.7 7.5 6-10 HF 20 FN32 6 4.5 9 6-10 HF 25 FN32 7.5 5.5 11 9-15 HF 32 FN 32 10 7.5 14 9-15 HF 32 FN 32 7.5 5.5 11 9-15 HF 32 FN 32 MN 25 10 7.5 14 9-15 HF 32 FN32 MN 2 MNX 25 DOL 12.5 9.3 18 14-23 HF 50 FN 63 MN 32 DOL 15 11 21 14-23 HF 63 FN 63 15 11 21 20-33 HF 63 FN 63 17.5 13 24 20-33 MN 2 MNX 32 HF 63 FN 63 20 15 28 20-33 HN/100 63 FN 100 MN 45 25 18.5 35 30-50 HN/100 80 FN 100 MN 5 MNX 45 DOL 30 22.5 40 30-50 HN/100 80 FN 100 30 22.5 40 30-50 HN/100 80 FN 100 MN 65 35 26 47 30-50 HN/100 100 FN 100 MN 5 MNX 70 DOL 40 30 55 45-75 HN/100 100 FN 100 Selection Chart for MN DOL Starters Type 45 33.5 60 45-75 HN/100 100 FN 100 Maximum Motor Rating at 415V, 3 O 50Hz Approx. Full Load Current In HP KW ( A) Chart for Star-Delta starters p hase Relay Recommended Switch Current Range Relay Contactor Back-up HRC Fuse Disconnector n i /,u (A) Fuse Unit Type Rating (A) MN 16 10 7.5 14 8.08 6-10 HF 20 FN 32 SASD/ 12.5 9.3 18 10.4 9-15 MN 2 MNX 18 HF 32 FN 32 15 11 21 12.1 9-15 HF 32 FN32 MN 25 20 15 28 16.2 14-23 HF 40 FN 63 MN 2 MNX 25 SASD/ 25 18.5 35 20.2 14-23 HF 50 FN 63 MN 32 30 22.5 40 23 20-33 HF 63 FN 63 SASD/ MN 2 MNX 32 35 26 47 27 20-33 HN/00 63 FN 100 MN 45 40 30 55 31.8 30-50 HN/00 63 FN 100 45 33.5 60 34.6 30-50 MN 5 MNX 45 HN/00 80 FN 100 50 37.5 66 38.2 30-50 HN/00 80 FN 100 60 45 80 46.2 45-75 HN/00 100 FN 100 MN 65 65 48.5 87 50 45-75 HN/00 100 FN 100 MN 5 MNX 70 70 52 94 54.5 45-75 HN/00 125 FN 125 75 55 100 57.5 45-75 HN/00 125 FN 125 MN 80 90 67.5 120 69.2 45-75 MN 5 MNX 80 HN/0 160 Fn 200 MN 110 100 75 135 77.9 66-110 HN/0 160 FN 200 MN 5 MNX 110 125 90 165 95 66-110 HN/0 200 FN 200 MN 140 150 110 200 115 90-150 HN/1 250 FN 250 MN 12L MNX 140 175 130 230 132.8 90-150 HN/1 250 FN 250 Selection Chart for MN Star-Delta Starters 3

Ordering Information - MN DOL Starter* Example: MN 16 DOL - 240V with relay range 9-15 A Ordering Information - SS94015BOBO Srarter Type Version MN 16 MN 25 MN 32 MN 45 MN 65 Cat. No. SS94351 SS94352 SS94353 SS94017 SS94018 Rated control Relay Range voltage (Us) V c 240 360 415 3.0-5.0 - - - - - 4.5-7.5 - - - - - 6.0-10 - - - - - 9.0-15 - BOBO - - - 14-23 - BODO - - - 20-33 - - BOEO - - 30-50 - - - - - 45-75 - - - - - 3.0-5.0 COSO - - - - 4.5-7.5 COUO - - - - 6.0-10 COVO - - - - 9.0-15 COBO COBO - - - 14-23 - CODO - - - 20-33 - - COED - - 30-50 - - - - - 45-75 - - - - - 3.0-5.0 DOSO - - - - 4.5-7.5 DOUG - - - - 6.0-10 DOVO - - - - 9.0-15 DOBO DOBO - - - 14-23 - DODO - - - 20-33 - - DOEO - - 30-50 - - - DOGO - 45-75 - - - - DOJO Ordering Information - MN Star- Delta Starter* Example: MN 16 SASD - 360V with relay range 9-15 A Ordering Information - SS94019COBO Srarter Type Version MN 16 MN 25 MN 32 MN 45 MN 65 MN 80 MN 110 MN 140 Cat. No. Rated control voltage (Us) VA, 360 415 SASD SS94361 SS94363 SS94365 - - - - - SS94362 SS94364 SS94366 SS94021 SS94022 SS94705 SS94706 SS94707 Relay Range 6.0-10 COVO - - - - - - - 9.0-15 COBO - - - - - - - 14-23 - CODO - - - - - - 20-33 - - COED - - - - - 30-50 - - - - - - - - 45-75 - - - - - - - - 66-110 - - - - - - - - 90-150 - - - - - - - - 6.0-10 DOVO - - - - - - - 9.0-15 DOBO - - - - - - - 14-23 - DODO - - - - - - 20-33 - - DOEO - - - - - 30-50 - - - DOGO - - - - 45-75 - - - - DOJO DOJO - - 66-110 - - - - - - DOKO - 90-150 - - - - - - - DOMO * Note: These are the stnadard combinations of relay and contactor. Any other combinations can be supplied on request. 4

Overall Dimensions 4 MOUNTING HOLES 0 6 -Ol to $l e m 235 136 ----------------------------------------- 105 128 2.3 4- I 139 DOL Starters MN 16, MN 25, MN 32 O11 S 200 J IOlmI e 352 I 153 297 4 MOUNTING HOLES08.5 Alk 026 Starters MN 45, MN 65 212.6 4 MOUNTING HOLES 011 Starters MN 80F, MN 110F, MN 140F 5

For selection and product demonstration, please contact any of our branch offices listed below: REGISTERED OFFICE AND L&T House A28,lndira Nagar HEAD OFFICE Group MIG - 5 Faizabad Road L&T House, Ballard Estate Padmanabhpur Lucknow 226 016 P. O. Box 278 Durg 491 001 Uttar Pradesh Mumbai 400 001 Tel: 0788-2200105, 2322809 Tel: 0522-4040905 / 902 / 903 Tel: 022-67525656 Fax: 0788-2210161 Fax: 0522-2311671 Fax: 022-67525858 e-mail: esp-lko@lntebg.com Website: www.larsentoubro.com Al Astronauts Avenue Bidhan Nagar Plot No. 518 ELECTRICAL STANDARD PRODUCTS (ESP) Durgapur 713 212 4th Main Road 501, Sakar Complex Tel: 0343-2536891 / 952 K.K. Nagar Opp. Gandhigram Rly. Station Fax: 0343-2536493 Madurai 625 020 Ashram Road e-mail: esp-dgp@lntebg.com Tel: 0452-2537404/303 Ahmedabad 380 009 Fax: 0452-2537552 Tel: 079-55304007-11, 55304000/1 (Faridabad Switchgear Works) e-mail: esp-mdu@lntebg.com Fax: 079-26580491 12/4, Delhi-Mathura Road e-mail: esp-ahm@lntebg.com Faridabad 121 003 North Wing, Level II, Tel: 0129-2277543, 2275314 Gate 7, Powai 38, Cubbon Road, Post Box 5098 Fax: 0129-2275405 Mumbai 400 072 Bangalore 560 001 e-mail: esp-fbd@lntebg.com Tel: 022-67052287 / 2661 / 2737 Tel: 080-25020100 / 325 Fax: 022-67051112 Fax: 080-25580525 Milanpur Road, Bamuni Maidan e-mail: esp-bom@lntebg.com e-mail: esp-blr@lntebg.com Guwahati 781 021 Tel: 0361-2550565 8B, Farmland, Ramdaspeth 131/1, Zone II Fax: 0361-2551308 Behind Hotel Radhika Maharana Pratap Nagar e-mail: esp-gau@lntebg.com Nagpur 440 010 Bhopal 462 011 Tel: 0712-2420641 / 24 Tel: 0755-4233907 / 8 / 9 5-10-173, Fatah Maidan Road Fax: 0712-2420619 Fax: 0755-2769264 R. O. Box 12 e-mail: esp-ngp@lntebg.com e-mail: esp-bho@lntebg.com Hyderabad 500 004 Tel: 040-23296468 32, Shivaji Marg, P.O. Box 6223 Plot No. 559, Annapurna Complex Fax: 040-23242356 New Delhi 110 015 Lewis Road e-mail: esp-hyd@lntebg.com Tel: 011-41419500 / 1, 41419515 Bhubaneswar 751 014 Fax: 011-41419600 Tel: 0674-2537301, 2436696 D-24, Prithvi Raj Road e-mail: esp-del@lntebg.com Fax: 0674-2537309 C-Scheme e-mail: esp-bbi@lntebg.com Jaipur 302 001 L&T House, P.O. Box 119 Tel: 0141-2341385/386 191/1, Dhole Patil Road SCO 32, Sector 26-D Fax: 0141-2373280 Puna 411 001 Madhya Marg, P. O. Box 14 e-mail: esp-jai@lntebg.com Tel: 020-26135048, 26135611 Chandigarh 160 026 Fax: 020-26129586, 26124910 Tel: 0172-2790750 / 151 Akashdeep Plaza, 2nd Floor e-mail: esp-pnq@lntebg.com Fax: 0172-2792764 P. O. Golmuri e-mail: esp-chd@lntebg.com Jamshedpur 831 003 3rd Floor, Vishwakarma Chambers Jharkhand Majura Gate, Ring Road 10, Club House Road Tel: 0657-2433673 Surat 395 002 Chennai 600 002 Fax: 0657-2341250 Tel: 0261-2473726 Tel: 044-28462072 / 4 e-mail: esp-jam@lntebg.com Fax: 0261-2477078 Fax: 044-28462102 e-mail: esp-sur@lntebg.com e-mail: esp-maa@lntebg.com Skybright Bldg. M.G. Road Radhadaya Complex 67, Appuswamy Road Ravipuram Junction Old Padra Road Post Bag 7156 Emakulam Near Charotar Society Opp. Nirmala College Kochi 682 016 Vadodara 390 015 Coimbatore 641 045 Tel: 0484-2358513, 2358761 Tel: 0265-6613610/11/12 Tel: 0422-2588120, 2588123 Fax: 0484-2358982 Fax: 0265-2336184 Fax: 0422-2588148 e-mail: esp-cok@lntebg.com e-mail: esp-bar@lntebg.com e-mail: esp-cbe@lntebg.com 3-B, Shakespeare Sarani 48-8-16, Dwarakanagar Kolkata 700 071 Visakhapatnam 530 016 Tel: 033-44002301/2/3/4/5, 44002572 Tel: 0891-2755493, 2704928 Fax: 033-22822589 Fax: 0891-2746075 e-mail: esp-ccu@lntebg.com e-mail: esp-viz@lntebg.com Product improvement is a continuous process. For the latest information and special applications, please contact any of our offices listed here. L&T SWITCH kllir Electrical Standard Products Larsen & Toubro Limited Powai Campus, Mumbai 400 072 Tel: 022-6705 0505 Fax: 022-67051324 / 1746 E-mail: esp@lntebg.com Website: www.lntebg.com LARSEN & TOUBRO LIMITED Its all about Imagineering' SP 01936 R 10407