ZR125KC-TFD HCFC, R-22, 5 Hz, 3 - Phase, 38/42 V Production Status: Available for sale to all U.S. customers. Please check with your local Copeland representative for international availability. Evap( F)/Cond( F) RG( F)/Liq( F) Performance 45/13 65/115 45/1 65/85 Capacity (Btu/hr): 15 122 Power (Watts): 91 665 Current (Amps): EER (Btu/Wh): Mass Flow (lbs/hr): 15.9 11.5 154 12.5 18.4 158 Sound Power (dba): Vibration (mils(peak-peak)): 77. Ave 82. Max 2.5 Ave 3.5 Max Number of Cylinders: Bore Size (in): Stroke(in): Overall Length (in): Overall Width (in): Overall Height (in): Suction Size (in): Discharge Size (in): Initial Oil Charge (oz): Oil Recharge (oz): Net Weight (lbs):.. 1.38 11.19 21.5 Mechanical CIR (in^3/rev): CFH (ft^3/hr): Mounting Length (in): Mounting Width (in): Mounting Height (in): 1 3/8 Stub 7/8 Stub 11 16 144. 1.16 117.613 7.5 7.5 21.75 Electrical RLA: 19.2 MCC (Amps): 26.9 UL File No.: SA-2337 LRA-Low: 11. RPM: 29 UL File Date: 27-Sep-1996 LRA-High: 118. Max Operating Current: 19.6 CSA File No.: LR314C LRA-Half Winding: Alternate Applications Refrigerant Frequency (Hz) Phase Voltage Application R-22 HCFC 6 3 46
ZR125KC-TFD HCFC, R-22, 5 Hz, 3 - Phase, 38/42 V Production Status: Available for sale to all U.S. customers. Please check with your local Copeland representative for international availability. Evap( C)/Cond( C) RG( C)/Liq( C) Performance 7.2/54.4 18.3/46.1 7.2/37.8 18.3/29.4 Capacity (Watts): 31 36 Power (Watts): 91 665 Current (Amps): EER (COP): Mass Flow (g/s): 15.9 3.37 194 12.5 5.39 199 Sound Power (dba): Vibration (mm(peak-peak)): 77 Ave 82 Max.63 Ave.89 Max Number of Cylinders: Bore Size (mm): Stroke(mm): Overall Length (mm): Overall Width (mm): Overall Height (mm): Suction Size (in): Discharge Size (in): Initial Oil Charge (liters): Oil Recharge (liters): Net Weight (kg): Mechanical 263.652 284.226 546.1 CIR (cm^3/rev): CFH (cm^3/hr): Mounting Length (mm): Mounting Width (mm): Mounting Height (mm): 1 3/8 Stub 7/8 Stub 3.253 3.135 65.317.166 28815.6 19.5 19.5 552.45 Electrical RLA: 19.2 MCC (Amps): 26.9 UL File No.: SA-2337 LRA-Low: 11. RPM: 29 UL File Date: 27-Sep-1996 LRA-High: 118. Max Operating Current: 19.6 CSA File No.: LR314C LRA-Half Winding: Alternate Applications Refrigerant Frequency (Hz) Phase Voltage Application R-22 HCFC 6 3 46
ZR125KC-TFD HCFC, R-22, 6 Hz, 3 - Phase, 46 V Production Status: Available for sale to all U.S. customers. Please check with your local Copeland representative for international availability. Evap( F)/Cond( F) RG( F)/Liq( F) Performance 45/13 65/115 45/1 65/85 Capacity (Btu/hr): 126 148 Power (Watts): 11 815 Current (Amps): EER (Btu/Wh): Mass Flow (lbs/hr): 16.3 11.5 186 13 18.2 191 Sound Power (dba): Vibration (mils(peak-peak)): 8. Ave 85. Max 2.5 Ave 3.5 Max Number of Cylinders: Bore Size (in): Stroke(in): Overall Length (in): Overall Width (in): Overall Height (in): Suction Size (in): Discharge Size (in): Initial Oil Charge (oz): Oil Recharge (oz): Net Weight (lbs):.. 1.38 11.19 21.5 Mechanical CIR (in^3/rev): CFH (ft^3/hr): Mounting Length (in): Mounting Width (in): Mounting Height (in): 1 3/8 Stub 7/8 Stub 11 16 144. 1.16 1228.161 7.5 7.5 21.75 Electrical RLA: 19.2 MCC (Amps): 26.9 UL File No.: SA-2337 LRA-Low: RPM: 35 UL File Date: 27-Sep-1996 LRA-High: 125. Max Operating Current: 19.6 CSA File No.: LR314C LRA-Half Winding: Alternate Applications Refrigerant Frequency (Hz) Phase Voltage Application R-22 HCFC 5 3 38/42
ZR125KC-TFD HCFC, R-22, 6 Hz, 3 - Phase, 46 V Production Status: Available for sale to all U.S. customers. Please check with your local Copeland representative for international availability. Evap( C)/Cond( C) RG( C)/Liq( C) Performance 7.2/54.4 18.3/46.1 7.2/37.8 18.3/29.4 Capacity (Watts): 37 435 Power (Watts): 11 815 Current (Amps): EER (COP): Mass Flow (g/s): 16.3 3.37 234 13 5.33 241 Sound Power (dba): Vibration (mm(peak-peak)): 8 Ave 85 Max.63 Ave.89 Max Number of Cylinders: Bore Size (mm): Stroke(mm): Overall Length (mm): Overall Width (mm): Overall Height (mm): Suction Size (in): Discharge Size (in): Initial Oil Charge (liters): Oil Recharge (liters): Net Weight (kg): Mechanical 263.652 284.226 546.1 CIR (cm^3/rev): CFH (cm^3/hr): Mounting Length (mm): Mounting Width (mm): Mounting Height (mm): 1 3/8 Stub 7/8 Stub 3.253 3.135 65.317.166 34777.67 19.5 19.5 552.45 Electrical RLA: 19.2 MCC (Amps): 26.9 UL File No.: SA-2337 LRA-Low: RPM: 35 UL File Date: 27-Sep-1996 LRA-High: 125. Max Operating Current: 19.6 CSA File No.: LR314C LRA-Half Winding: Alternate Applications Refrigerant Frequency (Hz) Phase Voltage Application R-22 HCFC 5 3 38/42
RATING CONDITIONS 2 F Superheat 15 F Sub Cooling 95 F Ambient Air Over 5 Hz Operation AIR CONDITIONING ZR125KC 3 PHASE SCROLL HCFC-22 COMPRESSOR 38/42-3-5 -TFD Condensing CAPACITY (BTU/HR) Evaporating Temperature Temperature -1 1 2 3 4 45 5 55 F ( C) (-23.3) (-17.8) (-12.2) (-6.7) (-1.1) (4.4) (7.2) (1.) (12.8) 8 (26.7) 48 523 663 827 114 1225 1339 1459 1584 9 (32.2) 386 495 627 784 965 1169 1279 1395 1517 1 (37.8) 367 469 595 745 919 1115 1222 1335 1453 11 (43.3). 444 563 76 873 162 1166 1275 139 12 (48.9).. 529 665 825 18 118 1213 1324 13 (54.4)... 62 773 949 146 1148 1255 14 (6.).... 715 884 977 175 1179 15 (65.6)..... 89 899 994 194 Condensing EER (BTU/WATT-HR) Evaporating Temperature Temperature -1 1 2 3 4 45 5 55 F ( C) (-23.3) (-17.8) (-12.2) (-6.7) (-1.1) (4.4) (7.2) (1.) (12.8) 8 (26.7) 8.3 1.5 13. 16. 19.3 22.9 24.6 26.4 28.1 9 (32.2) 7.1 8.9 11.1 13.6 16.5 19.7 21.3 22.9 24.5 1 (37.8) 6. 7.5 9.4 11.6 14.2 17. 18.4 19.9 21.4 11 (43.3). 6.4 7.9 9.9 12.1 14.6 15.9 17.2 18.6 12 (48.9).. 6.7 8.3 1.2 12.4 13.6 14.8 16. 13 (54.4)... 6.9 8.5 1.4 11.5 12.5 13.6 14 (6.).... 7. 8.6 9.5 1.5 11.5 15 (65.6)..... 7. 7.8 8.6 9.5 Condensing POWER (WATTS) Evaporating Temperature Temperature -1 1 2 3 4 45 5 55 F ( C) (-23.3) (-17.8) (-12.2) (-6.7) (-1.1) (4.4) (7.2) (1.) (12.8) 8 (26.7) 489 5 59 516 524 536 544 553 564 9 (32.2) 546 559 568 575 583 593 6 68 618 1 (37.8) 61 624 633 641 648 657 663 67 679 11 (43.3). 698 78 716 722 73 735 74 748 12 (48.9).. 795 82 88 813 817 822 827 13 (54.4)... 92 96 91 913 916 92 14 (6.).... 121 123 125 127 129 15 (65.6)..... 1155 1155 1155 1156 Condensing CURRENT (AMPS) @ 38 Volts Temperature -1 1 2 3 4 45 5 55 F ( C) (-23.3) (-17.8) (-12.2) (-6.7) (-1.1) (4.4) (7.2) (1.) (12.8) 8 (26.7) 1.5 1.6 1.7 1.8 1.9 11. 11.1 11.2 11.3 9 (32.2) 11.1 11.2 11.4 11.5 11.6 11.7 11.8 11.9 12. 1 (37.8) 11.9 12. 12.2 12.3 12.4 12.5 12.5 12.6 12.7 11 (43.3). 13. 13.1 13.2 13.3 13.4 13.5 13.5 13.6 12 (48.9).. 14.3 14.3 14.4 14.5 14.6 14.6 14.7 13 (54.4)... 15.7 15.8 15.8 15.9 15.9 16. 14 (6.).... 17.4 17.4 17.4 17.5 17.5 15 (65.6)..... 19.3 19.3 19.3 19.3 Condensing MASS FLOW (LBS/HR) Evaporating Temperature Temperature -1 1 2 3 4 45 5 55 F ( C) (-23.3) (-17.8) (-12.2) (-6.7) (-1.1) (4.4) (7.2) (1.) (12.8) 8 (26.7) 523 663 828 12 124 148 16 174 188 9 (32.2) 516 651 815 1 122 146 159 172 186 1 (37.8) 51 643 84 993 121 145 158 171 185 11 (43.3). 634 794 981 12 144 157 17 185 12 (48.9).. 779 966 118 142 156 169 184 13 (54.4)... 943 116 14 154 168 182 14 (6.).... 113 137 151 165 18 15 (65.6)..... 133 147 161 176 Nominal Performance Values (±5%) based on minimum 24 hours run-in. Subject to change without notice. 22 Copeland Corporation #2.22AC5-225.3 Printed in U.S.A. Issued 4-18-22 98-56
RATING CONDITIONS 2 F Superheat 15 F Sub Cooling 95 F Ambient Air Over 5 Hz Operation ZR125KC 3 PHASE HCFC-22 PLEASE NOTE: Compressor requires a minimum of 24 hours "run-in" to attain specified performance. CAPACITY (BTUH X 1) 16 15 14 13 12 11 1 9 8 7 6 CAPACITY Cond. Temp. ( F) Cond. Press. (PSIG) 8 144 9 168 1 196 11 226 12 26 13 297 14 337 15 382 5 4 3-1 16.5-5 2.1 24. 5 28.2 1 32.8 15 37.7 2 43. 25 48.8 3 54.9 35 61.5 4 68.5 45 76. 5 84. 55 92.6 Evap. Temp. ( F) Evap. Press. (PSIG) 2 CURRENT @ 38 Volts 19 15 382 18 CURRENT (AMPS) 17 16 15 14 13 12 14 337 13 297 12 26 11 226 1 196 9 168 8 144 11-1 16.5-5 2.1 24. 5 28.2 1 32.8 15 37.7 2 43. 25 48.8 3 54.9 35 61.5 4 68.5 45 76. 5 84. 55 92.6 Evap. Temp. ( F) Evap. Press. (PSIG) #2.22AC5-225.3 Copeland Corporation Issued 4-18-22 Sidney, Ohio 45365-669
USE COPPER CONDUCTORS ONLY. USE THIS EQUIPMENT ON A GROUNDED SYSTEM ONLY. USE MINIMUM 75C WIRE FOR AMPACITY DETERMINATION. INTERNAL MOTOR PROTECTION- ALLOW TIME FOR RESET. PRIMARY SINGLE PHASE FAILURE PROTECTION IS PROVIDED. CRANKCASE HEATER, WHEN APPLIED, MUST BE CONNECTED ONLY TO ITS RATED VOLTAGE. OVERCURRENT PROTECTION DEVICE RATING AND TYPE MUST BE IN ACCORDANCE WITH REGULATORY AGENCY END PRODUCT APPROVALS -SEE SYSTEM NAMEPLATE TO CORRECT IMPROPER MOTOR ROTATION. SWITCH ANY TWO SUPPLY LINES. 1 L1 5-922- 3-98 L2 XX 2 MOTOR WINDING CONNECTION 3 L3