From the dawn of Excellence emanates the high noon of Performance.

Similar documents
From the dawn of Excellence emanates the high noon of Performance.

Series Motor Protection

Micro Controller based Motor Protection Relay & Motor Management System

Metering Products. Metering Products Protection Units April 1, Price List. Price List. With effect from April 1,

Ambilin Incorporate.

Metering Products Protection Units Current Transformers. April 1, 2015

Starters. Overview. Siemens caters with following types of starters to agricultural and industrial sector.

M440 MOTOR PROTECTION, EARTH FAULT LOCKOUT & MANAGEMENT RELAY VERSION 3.5 NINGI SERVICES (PTY) LTD

LA Motor Protection. A South African Company to be Proud of

KD LV Motor Protection Relay

Part # Features & Applications Specifications Cross Reference

DIP SWITCH BASED EARTH LEAKAGE RELAY (ELR) WITH CORE BALANCE CURRENT TRANSFORMER (CBCT / ZCT) EL SERIES

Rotomatik Corporation

ICG Switchgear Price List 2009

Franklin Electric Submersible Motors SUBMERSIBLE MOTORS. Motors Accessories. Product Information and Service

TENDER FOR FOR 2 X 1010 KVA, 1500 RPM, 415 V DG SETS FOR CONSTRUCTION OF NEW CDRI CAMPUS AT SITAPUR ROAD, LUCKNOW (U.P.) SUMMARY OF PRICE BID

Application Engineering

Bulletin 825 SMM Smart Motor Manager

TOTALINE PROTECTION CONTROLS

Quality Products, Prompt Service, Trustful Relationships.

CI-tronic Soft Start Motor Controller Type MCI 25B with Brake

Application Engineering

Designed for ease of integration with automation systems

GCU-10. Automatic Engine Control Unit Operators Manual

PRODUCT / TEST MANUAL 2L9K2 BATTERY EARTH FAULT RELAY

DRAFT 1400HP 1000HP 100HP. Reduced Voltage Solid State Starters. Softstarters SOFT. PF Controller PCS Controller PDS Controller V 1...

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

2.1 Warnings & Agency Approvals Electrical Connections - Specifications Standard Wiring Configurations...2 4

XM1 - Motor protection relay

SALES PRESENTATION FOR RELAYS, CONTACTORS & MOTOR STARTER TESTING EQUIPMENTS

SECTION MOTOR CONTROL

Open Chassis Star-Delta Starter User Guide

B BASIC HEAT TREATMENT CONSOLE

Variable Speed Product Line

MCD Pump Application Module

Contactors and Overloads MC

TDX - Taco Duplex Starter with

MODEL 422 Submersible Pump Controller

Defining a timer in simple terms. Which actions are executed? Which market are they used frequently? Benefits and Advantages

TECHNOLOGICALLY ADVANCED ENERGY PRODUCTS. Product Preview & Price List 2018

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

SDS Enclosed Star-Delta Starter User Guide

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

NOCCHI FREQUENCY CHANGER PRESSURE BOOSTERS WITH VARIABLE SPEED

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

32XR. 3 Phase Duplex Pump Control Panel (Level Transmitter Based) Quick Start Guide

331-SV. User Manual THREE PHASE DUPLEX LIFT STATION CONTROL PANEL WITH STATIONVIEW CONTROLLER. Ashland, OH

EPS-ECONOMY PUMP STARTER

ELECTRICAL SYSTEM RP-7

Selection Guide Motor Control Device Solutions

HOTLINE ELECTRICAL TRADING

Cascade CD101 Auto-Start Controller. Installation and Operations Manual Sections 40 & 75

CG PRESSURE BOOSTING SYSTEMS

Type CDG 14 Extremely Inverse Time Overcurrent and Earth Fault Relay

Designed for Today s World

Product selection table

Designed for Today s World

CI-TI Contactors and Motor Starters Type CI 6-50

Hydrovar and Packaged Hydrovar

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

CONSTANT PRESSURE CONTROLLERS

MINIATURE CIRCUIT BREAKER

SINGLE-PHASE PUMP START AND PROTECTION BOX Type V1M, V1N, V1E, V1F

Contents. We build a better future! MCC HCB

825-P Modular Protection System for motors Specification Guide

Designed for Today s World

Electromagnetic Industries LLP

UNIVERSAL PRODUCT RANGE. Performance I Durability I Serviceability

SDM72 Start on Demand Modules

BRSDRIVE ITT. Goulds Pumps. S-Drive. Simplex Variable Speed Submersible Pump Controller. Engineered for life

Meta Solution. Contactors and Overload relays

ICON 2 1. FEATURES AND CHARACTEIRICS

DIGITAL EARTH LEAKAGE RELAY

Legat-65. Voltage Stabilizer Technical Certificate. NOVATEK-ELECTRO LTD Research-and-Manufacture Company

ADJUSTABLE FREQUENCY CONTROLS SENSORLESS VECTOR CONTROL. Dual Rating. Technologies Inc. mgitech.com NRTL/C CERTIFIED

CP Automatic capacitor bank

Generator Controller Manual

Soft Starter. Types RSBD. Product Description. Type Selection. Ordering Code RSB D E V 61 HP

New range of reclosing systems

Moulded Case Circuit Breakers

PHASE PERFECT PHASE CONVERTERS OPERATION & INSTALLATION MANUAL PHASE TECHNOLOGIES, LLC


SECTION MICROPROCESSOR TRIP UNITS FOR LV CIRCUIT BREAKERS. This section is organized as indicated below. Select desired Paragraphs.

SD Series Non-Fused Load Switches

ABB Softstarter Benefits Charnchanok Thongprad

1 Phase electronic contactor (SC 1)

Auto Mains Failure AMF Controller AE10113

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

power made simple kva RANGE Performance I Durability I Serviceability

Moulded case circuit breakers

Electronic timers CT-S range Function diagrams

GRUNDFOS PRODUCT GUIDE. Redi-Flo3 and CU 300. Environmental Pumps 60Hz

AQUAVAR Intelligent Pump Controller TECHNICAL BROCHURE BCPAQIPC R2

60 Series Engine Controls

NOVATEK-ELECTRO LTD Research-and-Manufacture Company SINGLE PHASE VOLTAGE MONITORING RELAY RN-113 USERS MANUAL

VOLUME: IIIC SCHEDULE IIIC/4 11 KV AND 3.3 KV SWITCHGEARS

canfield connector 8510 Foxwood Court Youngstown, Ohio (330) Fax: (330)

Transcription:

From the dawn of Excellence emanates the high noon of Performance.

Gelco Electronics is a full service electronic company that manufactures superior quality electronic control & measuring equipment alongwith power saving devices. Established in 1984, the company is located in the industrial belt of Ahmedabad, which is one of the fastest developing metropolitan cities of India. Our state of the art manufacturing facility with its prolific R&D centre in conjunction with our strict adherence to quality control and safety norms has ensured an impressive growth record in these past three decades. More importantly, it has gained a reputation of Excel- lence & Dependability from its clients. After achieving wide success in the Indian market, Gelco Electronics is now spreading its wings internationally. To attain the same level of success globally, Gelco Electronics has conducted extensive research in each market to understand their electrical equipment s needs and subsequently, developed specific products for them that are longlasting, efficient and safe. R a n g e of P r o d u c t s Single Phase Motor Starters & Control Panel Three Phase DOL Motor Starters & Control Panel Three Phase Star Delta Motor Starters & Control Panel Duty Stand by Panel for Duplex Pumps Panel Accessories A p p l i c at i o n s Home Agriculture Industries

SINGLE PHASE MOTOR STARTER Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC +20% INDEX Topic Page Single Phase Motor Starter 1-2 Single Phase Electronic Control Panel 3 Three Phase Dol Motor Starter 4-5 Three Phase Dol Motor Starter - Metal Body 6 Three Phase Star Delta Motor Starter 7 Three Phase Dol Electronic Control Panel 8 Three Phase Star Delta Electronic Control Panel 9 Duty Stand By Panel For Duplex Pumps Operation 10 Stabilizer 11 Auto Switch 12 Motor Starter 13 A.C. Switch 14 Phase Failure Relay 15 Phase Failure Relay 16 Motor Protection Relay 17 Pump Protection Relay 18 Analog Timer 19-20 Digital Timer 21 Digital Time Switch 22 Earth Leakage Relay 23-24 Earth Leakage Circuit Breaker 25 Panel Meters 26 Automatic Light Controller 27 Spp With Water Level Guard 28 Water Level Controller 29-30 (1.1) GSS-MCB Easy to operate Overload protection through MCB Economical Solution Enclosure made from Engineering grade Plastic (ABS) Only for Oil Filled Pump set Motor H.P. Run Capacitor MCB 0.75 HP 0 + 25 MFD 10 Amp. 1.0 HP 0 + 36 MFD 10 Amp. 1.5 HP 0 + 50 MFD 16 Amp. 2.0 HP 0 + 72 MFD 25 Amp. (1.2) GSS-RE Electronic Start/Stop push buttons. Electronic Overload protection High voltage protection above 270 Vac. Low voltage protection below 150 Vac. Engineering grade plastic enclosure (ABS). Facility to connect Gelco Water Level Controller Adaptor NOTE: A wide range of products which can be offered on request. We can supply starter / panel / A.T.S. panel / 60 Hz starter / panel as per customer s specifications. A wide range of lighting products which can be offered on request. We can supply submersible flat & round, PVC & rubber, 3 core and 4 core cable. We can supply submersible pumpsets, monoblock pumpsets, industrial pumpset, electric induction motors & UPVC column pipes etc. Due to continues R & D; specifications, construction of materials, design, out look, colour & finishing etc. can be changed without intimation. ( LLC-001D/LLC-001) Only for Oil Filled Pump set Motor H.P. Run Capacitor MCB 0.75 HP 0 + 25 MFD 4-10 Amp. 1.0 HP 0 + 36 MFD 4-10 Amp. 1.5 HP 0 + 50 MFD 10-16 Amp. 2.0 HP 0 + 72 MFD 10-16 Amp. 1

SINGLE PHASE MOTOR STARTER Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC +20% SINGLE PHASE ELECTRONIC CONTROL PANEL Input Supply voltage : 230V, AC ±20% Output supply voltage : 230V, AC ±20% (1.3) DCP - RE Electronic Start/Stop Push button. In built digital volt and amp meter Latest Micro Controller Based Technology for better accuracy Presice protection against Overload( Over Current) Presice protection aganist high voltage Presice protection against low voltage Dry run protection ( Optional) Digital indication of fault condition. Engineering grade plastic enclosure( ABS) Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Parameters can be programmable Only for Oil filled pumpset Motor H.P. Run Capacitor 1.0 HP 36 MFD 1.5 HP 50 MFD 2.0 HP 72 MFD (2.1) MCB WS In built digital Volt and Amp. Meter ( GELCO ACCURA) Easy to operate Powder coated sheet metal enclosure. Submersible/Monoblock Pump set. MCB Start Capacitor Run Capacitor 10 100/120 MFD 36 MFD 20 150/200 MFD 36 + 36 MFD 25 200/250 MFD 36 + 36 MFD 25 200/250 MFD 50 + 50 MFD (2.2) DCP - 7201 Fully automatic Electronic Start/Stop facility Digital Micro Controller based technology Higher accuracy Digital indication of fault condition. Precise overload protection( Over Current) Precise Overvoltage protection Precise Under voltage protection Dry run Protection. Parameters can be programmable In built Auto ON/OFF timer ( 1-240 Minutes) Powder Coated sheet metal enclosure. Submersible/Monoblock Pumpset for water in residence, commercial, farming, gardening. Motor H.P. Start Capacitor Run Capacitor 1.0 HP 100/120 MFD 36 MFD 1.5 HP 150/200 MFD 36 + 36 MFD 2.0 HP 200/250 MFD 50 + 50 MFD 2 3

THREE PHASE DOL MOTOR STARTER Input/Output Voltage :415 V ± 20%VAC (3.1) GTW Current sensing unit Inverse current characteristics Electronic start/stop push button facility Electronic overload protection. Under voltage protection Dry run protection(optional). Reverse phasing protection Can be used up to 7.5Hp DOL moter/pumps Other Models are also available on request D.O.L. Submersible Pump set for water in residence, commercial, farming, gardening. Induction motor in industries Type GTW-304 GTW-305 GTW-306 (3.2) GTV Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. All facilities available as per GTW Current and voltage sensing unit Facility to connect GELCO Water Level Controller (Model LLC-001/LLC-001D) Can be used up to 7.5Hp DOL moter/pumps D.O.L. Submersible Pump set for water in residence, commercial, farming, gardening. Induction motor in industries Type GTV-304 GTV-305 GTV-306 Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. (3.3) GTA Current Sensing Unit Additional facility to make Motor/Pump ON automatically after power supply resumption. One minute Time Delay before start Can be used up to 7.5Hp DOL moter/pumps D.O.L. Submersible Pump set for water in residence, commercial, farming, gardening. Induction motor in industries Type GTA-304 GTA-305 GTA-306 (3.4) DCP - 304 Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. Used latest Micro controller based technolgy Electronic Start/Stop push button Inbuilt digital volt & amp Meter Digital display of fault condition Electronic overload protection Under voltage protection Dry Run protection Parameters can be programmed Reverse phasing protection Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Can be used up to 7.5Hp DOL moter/pumps Three phase DOL Submersible/Monoblock Pump set for water in residence, commercial, farming, gardening Current Range 2-5 Amp. 4 5

THREE PHASE DOL MOTOR STARTER - METAL BODY Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC THREE PHASE STAR DELTA MOTOR STARTER Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC (4.1) GEW-1(DOL) (5.1) GLO-FASD / SA-Metal Body Easy to operate Powder Coated sheet metal enclosure. Thermal Overload protection D.O.L Motors for water in residence, commercial, farming, gardening. Motor H.P. Overload range 5.0 HP 6 10 A 7.5 H.P 9 14 A 10 H.P 13 21 A Type Motor H.P. Overload range GLO-1 3 HP 6-10 A GLO-1 4 HP 6-10 A GLO-1 5 HP 6-10 A GLO-1 6 HP 6-10 A GLO-1 7.5 HP 6-10 A GLO-1 10 HP 6-10 A GLO-1 12 HP 10-16 A GLO-1.5 15 HP 13-21 A GLO-2 20 HP 20-32 A GLO-2 25 HP 20-32 A GLO-3 30 HP 28-42 A GLO-3 40 HP 28-32 A (4.2) GLO-1 (DOL) Motor H.P. Overload range 3.0 HP 6 10 A 5 H.P 6 10 A 7.5 H.P 10-16 A (4.3) GLO-1.5 / 2 / 3 (DOL) Motor H.P. Overload range 10 HP 13-21 A 15 H.P 20-32 A 20 H.P 20-32 A 30 H.P 28-42 A 6 7

THREE PHASE DOL ELECTRONIC CONTROL PANEL Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC THREE PHASE STAR DELTA ELECTRONIC CONTROL PANEL Input Voltage : 415 V ± 20% VAC Output Voltage: 415 V ± 20% VAC (6.1) DIGI : DOL In Built digital volt& Amp meter ( AVM-101) With bright LED phase indication with flash Automatic rotational phase to phase voltage indication Thermal overload protection Short circuit protection through MCB Under voltage protection Phase Failure Protection Auto Start after resumption of Supply Powder coated sheet Metal encloser For 3 phase DOL Submersible/Monoblock Pump set at irrigation, remote farms, unattainable gardening area. Relay Range 4-6.5 Amp. 6-10 Amp. 9-14 Amp. 13-21 Amp. (6.2) DCP-9603 Used latest Micro controller based technolgy Electronic Start/Stop push button Inbuilt digital volt & amp Meter Digital display of fault condition Electronic overload protection Under voltage protection Dry Run protection Parameters can be programmed Reverse phasing protection Facility to connect GELCO Water Level Controller Adaptor ( LLC-001D) Remote ON/OFF Powder coated sheet metal enclosure (7.1) DCP-9613 Fully Automatic Star delta starter Used latest micro controller based technology Inbuilt Digital volt /Amp Meter Electronic Overload protection Under Voltage protection Dry run protection Current sensing unit Reverse phase protection Parameters can be programmed Inbuilt Auto ON/OFF timer Powder coated sheet metal enclosure( IP55) Easy to maintain detachable spares Remote ON/OFF For three phase star delta motors used in farms, pumping station, municipal corporation Motor H.P. Overload Overload Motor H.P. range range 7.5 HP 8-20 Amp. 20.0 HP 16-40 Amp. 10.0 HP 8-20 Amp. 25.0 HP 16-40 Amp. 12.5 HP 8-20 Amp. 30.0 HP 32-80 Amp. 15.0 HP 16-40 Amp. 35.0 HP 32-80 Amp. Three phase DOL Submersible/Monoblock Pump set for water in residence, commercial, farming, gardening. Current Range 2-5 Amp. 4-10 Amp. 8-20 Amp. 8 9

DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION STABILIZER (8.1) DUTY STAND BY PANEL FOR DUPLEX PUMPS OPERATION Suitable for Single Phase & Three Phase Power Supply Volt Current and other Fault Conditions Display. Over voltage, under Voltage and Dry run Protection. Pump run and trip indication. Singe Phasing, Current and Voltage Sensing Protection. Selector/Toggle Switch for pump-1 and pump-2 parallel/alternate operation Manual/Auto ON/OFF Sheet metal enclosre with IP-55 Protection Suitable for booster pumps application (9.1) SERVO S e r v o C o n t r o l l e d Vo lta g e Sta b i l i z e r I/P: 170V to 270V (For 1 Phase) 360V to 460V (For 3 Phase) O/P: 215V AC +/- 1% for 1 Phase 415V AC +/- 1% for 3 Phase Capacity: Up to 400 KVA Cooling: Air Cooled Oil Cooled Balance or Unbalance Type, Display Parameter: Digital Volt and Amp. Meter Protection: Over Voltage, Under Voltage, Overload, Single Phasing Prevention Up to 35 HP (9.2) VIOLTEE Model Input Range Output Range Time Delay Application GDMS-20 170V AC 270V AC 220V AC ± 10% 10 Sec. Television GDMS-50 170V AC 270V AC 220V AC ± 10% 3 Min. Refrigerator DLC-50 170V AC 270V AC 210V AC 230V AC 10 Sec. Computer Model Input Range Output Range Time Delay GDMS - 300 GDMS - 400 GDMS - 500 170V AC 270V AC 170V AC 270V AC 170V AC 270V AC 220V AC ± 10% 220V AC ± 10% 220V AC ± 10% 3 Min. 3 Min. 3 Min. 10 11

AUTO SWITCH MOTOR STARTER (10.1) Auto Switch Voltage sensing unit Reverse phasing protection Engineering grade plastic enclosure (ABS) Auto ON after resumption of power supply Panel mountable Aux Supply Voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Start Time delay: 1 Minute Output: 1 C/O, 6 Amp (Resi.)@ 230 VAC For MCC of water pumps at remote farms, unattaindable area. (10.2.1) GSW I/P: 230 V, 1Phase, AC Supply ABS Body High/Low voltage protection Over Load Protection Variable current (Amp.) Setting Type GSW-104 GSW-105 GSW-106 GSW-107 GSW-108 Current Range: 2-5 Amp. 4-10 Amp. 8-14 Amp. 10-16 Amp. 14-22 Amp. (10.2.2) GSW-T I/P: 230 V, 1Phase, AC Supply, ABS Body High/Low voltage protection Over Load Protection Time Delay Facility Built in Starter Variable current /AMP setting Relay Type Switching device Type GSW-T-104 GSW-T-105 GSW-T-106 GSW-T-107 GSW-T-108 Current Range: 2-5 Amp. 4-10 Amp. 8-14 Amp. 10-16 Amp. 14-22 Amp. 12 13

A.C. SWITCH PHASE FAILURE RELAY ((10.2.2) AaCcSVCH Input Voltage: 85V Ac To 300V Ac Current Range: 2A to 16A High Voltage Protection : Above 280v High Voltage Cut Off: Below 260v Low Voltage Protection : Below 160v Low Voltage Cut in : Above 175v Over Load Protection programmable range 2A to 16A Time Delay : 60 sec.(1minute) After resumption of power supply Switching device : Relay Unique Alarm system for High voltage, Low voltage, Over load tripping Display of live voltage and live current by seven segment LED Display total run time of your load in hour Air-Conditioner, Television, Refrigerator, Domestic Flour Mill (10.3.1) PFR-104 Micro controller based technology Slim in size Higher accuracy Voltage sensing unit Reverse phasing protection Engineering grade plastic enclosure (ABS) DIN rail mountable Aux Supply Voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC of water pumps, generators, compressors (10.3.2) PFR-105 Micro controller based technology Slim in size Higher accuracy Voltage sensing unit Engineering grade plastic enclosure (ABS) DIN rail mountable Aux Supply Voltage: 415 VAC +/- 20 %, 50 Hz Phase unbalance volt: 45 V +/- 5 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC of water pumps, generators,compressors 14 15

PHASE FAILURE RELAY MOTOR PROTECTION RELAY (10.3.3) PFR-106 Micro controller based technology Slim in size Higher accuracy Voltage sensing unit (PFR 106) Under voltage protection (PFR 106) Reverse phasing protection Engineering grade plastic enclosure (ABS) DIN rail mountable Aux Supply Voltage: 415V AC +/- 20 %, 50 Hz Phase unbalance volt: 45V +/- 5 V Over voltage: Above 480 VAC Under Voltage: Below 320 V Tripping delay: 4 to 7 sec Output: 1 C/O, 6 Amp (Resi.) For MCC of water pumps, generators, compressors, Lift (10.4.1) MGR-101 Current Sensing unit Inverse current characteristics-2 Micro controller based technology Electronic Over load protection DIN rail & Panel Mountable Aux. Supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under Voltage : 80 % +/- 5 V of supply voltage Hysterius Current unbalance Phase-Phase: 50 % of Full Scale current Tripping Delay: 4 to 7 Sec. Dry run : 40% to 80% of Overload Setting MCC Panels of Water Pumps in hilly area. (10.4.2) MGR-102 Current & Voltage Sensing unit Inverse current characteristics-2 Micro controller based technology Electronic Over load protection Under voltage protection Reverse phase protection DIN rail & Panel Mountable Aux. Supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under Voltage : 80 % +/- 5 V of supply voltage Current unbalance Phase-Phase: 50 % of Full Scale current Voltage Unbalance Phase-Phase : 45 +/- 5 V Tripping Delay: 4 to 7 Sec. MCC Panels of water pumps. 16 17

PUMP PROTECTION RELAY ANALOG TIMER (10.5.1) PGR-101 Current Sensing unit Inverse current characteristics Micro controller based technology Electronic Over load protection Under voltage protection Reverse phase protection Output 1 c/o, 6Amp.(Resi) at 230VAC Dry run Protection ( Prodless ) (10.6.1) AC-22 Micro Controller based technology Cyclic timer Easy to programme,through dial on front DIN Rail Mountable Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC Output: 2 C/O Relay (5A @ 230 VAC) Control Action: Cyclic Time Range: 1-10 sec /min/hr. Selectable trough DIP Switch Reset: Power On reset MCC panel for water pumps, compressors, generators, airconditioners (10.5.2) PGR-102 Current & Voltage Sensing unit Inverse current characteristics Micro controller based technology Electronic Over load protection Under voltage protection Reverse phase protection Dry Run protection ( Prodless ) DIN rail & Panel Mountable Aux. Supply voltage 415 +/- 20 % VAC Over voltage: 120% +/- 5 V of supply voltage Under Voltage : 80 % +/- 5 V of supply voltage Current unbalance Phase-Phase: 50 % of Full Scale current Voltage unbalance Phase-Phae : 45 V +/- 5 V Dry Run : 40 % to 80 % of overload setting Tripping Delay: 4 to 7 Sec. (10.6.2) AS-22 Micro Controller based technology Single action timer Delay ON/ OFF timer (Selectable ) Easy to programme,through dial on front DIN Rail Mountable Engineering grade plastic enclosure (ABS) Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC Output: 2 C/O Relay (5A @ 230 VAC) Control Action: Selectable Delay ON/OFF Time Range: 1/3/10/30 sec/min/hr. Selectable trough DIP Switch Reset: Power On reset MCC panel for water pumps, compressors, generators MCC Panels of water pumps in hilly area 18 19

ANALOG TIMER DIGITAL TIMER (10.6.3) AS-21 Micro Controller based technology Single Action timer Delay ON/OFF timer (Factory set) Higher Accuracy Easy to programme,through dial on front DIN Rail Mountable (10.6.1) DT-48 Supply: 230V AC ± 20%, 50 Hz Output: 2 C/O Relay (5A @ 230 VAC) Control Action: Selectable Delay On/Off Time Range: 0-99.9 hr./min./sec. Display: 0.4 Seven Segment LED Accuracy: ± 0.01% of FSD Supply: 110/230/415V AC ± 20% 50 Hz, 12/24V AC/DC Output: 1 C/O Relay (5A @ 230 VAC) Control Action: Delay ON/ Delay OFF Time Range: 0-60 sec Reset: Power On reset MCC panel for water pumps, compressors,generators, airconditioners (10.6.4) SD-22 Micro Controller based technology Star Delta timer Din rail Mountable Higher Accuracy Easy to programme Engineering grade plastic Encloser(ABS) Supply: 110/230/415V AC ± 20% 50 Hz Output: 2 No. 1 C/O (230V AC, 6A) Time Range: y run up time 30/60 sec y to Δ change over time 30-100msec Reset: Power On Reset MCC panel for Star Delta pumps set. 20 21

DIGITAL TIME SWITCH EARTH LEAKAGE RELAY (10.7.1) DTS-502 Micro controller based technology On/ Off time is programmable 10 No of programme for On/Off Display of real time clock LED display of unit On Easy to programme Engineering grade plastic enclosure (ABS) Input Supply: 230 +/- 20 % VAC Output Supply: 230 +/- 20 % VAC Capacity: 20 amp at 230 VAC (Resi.) Water pump, Street lights (10.8.1) ELR-101 Micro Controller Based technology Higher precision Panel/Surface mountable Parameters are settable through knob in front panel Engineering grade plastic enclosure( ABS) With CBCT Auxiliary Supply: 110/280/415v, 50 HZ, Relay Contact: 1 C/O contact with 6 Amp. Resistive load at 230v AC, Leakage Current Range: 30 to 100 ma 0.1 to 1 Amp 0.5 to 5 Amp. Reset: Manual Operating Temp. : -5 C to 60 C (10.7.2) DTS-601 Micro controller based technology On/ Off time is programmable CBCT : 70,100,200,300 & 400mm Distribution panels for hotels, commercial complex, residential blocks, industrial complex. Mining industry 10 No of programme for On/Off Display of real time clock LED display of unit On Easy to programme Engineering grade plastic enclosure (ABS) Input Supply:415 +/- 20 % VAC Output :Potential Free 1 Contact,6 amp at 230 VAC (Resi.) Water pump, street lights 22 23

EARTH LEAKAGE RELAY EARTH LEAKAGE CIRCUIT BREAKER (10.8.2) ELR-9601 Micro Controller Based technology Higher precision DIN standard flush mountable(92x92) Digital display of leakage current Parameters are programmable Engineering grade plastic enclosure( ABS) With CBCT (10.9.1) EL+MCB Load Current Rating: 16A / 25A / 32A System Voltage: 230V AC, 1 Phase, 50Hz, Sensitivity: 3-50 ma, Tripping Time: <30 ms. High/Low Voltage Cut off, Overload Short Circuit Protection Supply Voltage : 75-275V AC/DC, 50/60 Hz 415V AC, 50Hz ± 15% Relay contact : 1 change over Potential free contact Positive safety output (Relay will energies on fault) Contact Rating: 6A at 230V AC / 30V DC Leakage current range : 50-999mA Trip time set: 0.05 to 5 Sec. Display: Digital 7seg. LED display Operating temp. : -5 c to 60 c CBCT 70, 100, 200, 300 & 400mm Distribution panels for hotels, commercial complex, residential blocks, industrial complex. Mining industry. 24 25

PANEL METERS AUTOMATIC LIGHT CONTROLLER (10.10) AVM-101 Micro Controller Based technology Inbuit C.T. Indicates phase phase voltage Indicates system current Indication for phase through high bright LED Voltage indiaction rotate at fixed interval for different phase-phase Panel mountable Aux. Supply : 415 +/- 20 % VAC Amp. Range : 4-40 Amp, 10-100 Amp (10.11.1) AUTOPHOTO Type AMPR PHASE APPLICATION ALC 6 ( I ) 1 6 Amp 1 Phase Indoor application ALC 10 ( I ) 1 10 Amp 1 Phase Indoor application ALC 10 ( O ) 1 10 Amp 1 Phase Indoor application ALC 25 ( I ) 1 25 Amp 1 Phase Indoor application ALC 25 ( O ) 1 25 Amp 1 Phase Indoor application ALC 16 ( O ) 3 16 Amp 1 Phase Indoor application ALC 32 ( O ) 3 32 Amp 1 Phase Indoor application ALC 63 ( O ) 3 63 Amp 1 Phase Indoor application Control Panels for housing, water pumps, industries, residential complex etc. 26 27

SPP WITH WATER LEVEL GUARD WATER LEVEL CONTROLLER (10.12.1) SWG Phase failure relay with dry run protection ( with Prod) Voltage sensing unit Under voltage protection Engineering grade plastic (HIPS) enclosure Panel mountable Available with S.S. Sensor. Aux Supply: 415 +/- 20 % VAC, 50 Hz Output : 1 C/O, 6Amp @ 230 AC (Resi.) Over voltage: Above 480 VAC Under voltage : Below 320 VAC MCC for sewage pumps (10.13.1) LLC-101 Easy to install DIN rail/ Panel mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for three phase motor starters Availabe with S.S Sensors/Magnetic sensors/float switch System Voltage: 415 VAC +/- 20 %, 50 Hz Output : 1 CO contact,1 Amp. At 415 VAC, Pf=0.5 MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. (10.13.2) LLC-2 Easy to install Panel mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for single phase motor starters Availabe with S.S Sensors/Magnetic sensors/float switch System Voltage: 230 VAC +/- 20 %, 50 Hz Output Voltage: 230 VAC +/- 20 %, 50 Hz Capacity 30 A at 230 VAC ( Resi.) MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. 28 29

WATER LEVEL CONTROLLER (10.13.3) LLC-2S Easy to install Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Specially for single phase submersible semi automatic motor starters Availabe with S.S Sensors/Magnetic sensors/float switch System Voltage: 230 VAC +/- 20 %, 50 Hz Output Voltage: 230 VAC+/- 20 %, 50 Hz Capacity 30 A at 230 VAC ( Resi.) MCC of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. (10.13.4) LLC-001/LLC-001D Water Level controller adopter Usefull with GELCO make single or three phase DOL or FASD starters having adopter facility only Easy to install Panel mountable Two tank controller Automatic control of starter according to set water level in tanks LED indications for water level in tank Availabe with S.S Sensors/Magnetic sensors/float switch Engineering grade plastic enclosure (ABS) For GELCO starter having micro controller based technology use LLC-001 D Motor starter of water pump in hotels, housed, high rise towers, societies, industries, commercial complexes, municipal water stations. 30 31

32