Application The DA03 serves as indicator of differential. Follow mounting instructions in accordance to application.

Similar documents
Differential Pressure Gauge

Data Sheet * * Differential pressure - Measuring device Pressure levels PN40/PN100. Important features. Application scopes

Explosion Proof Equipment General Overview*

* * Data sheet DA01 VUW (ATEX) Differential pressure measuring device Pressure levels PN250/PN400. Models for use in explosive areas

* * Data sheet MA15F... A/B/C/D. Diaphragm manometer for explosive areas

* * Data sheet DA A (ATEX) Differential pressure measuring device for potentially explosive areas

XMP ci. Process Pressure Transmitter with HART -communication. Ceramic Sensor. accuracy according to IEC 60770: 0.1 % FSO.


Absolute pressure gauge with diaphragm

Differential pressure gauge with diaphragm

Differential Pressure and Flow meters Accessories for the Media Series

Design and application

DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor

Differential Pressure Gauges Cryo Gauge Model , Cu-alloy Model , Stainless Steel Series

DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor

JUMO dtrans p20 DELTA

DMP 331P DMP 331P. Industrial Pressure Transmitter. Pressure Ports And Process Connections With Flush Welded Stainless Steel Diaphragm

Differential pressure gauge Model , copper alloy Model , stainless steel version

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm

DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. accuracy according to IEC 60770: 0.

Differential pressure transmitter PASCAL Ci4 Delta P

DMP 331 DMP 331. Industrial Pressure Transmitter for Low Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

JUMO dtrans p20. Process pressure transmitter. Type Brief description. Key features. Block diagram

BGN. All Metal Variable Area Flow Meter. Technical Data Sheet

SATRON VDt Differential Pressure Transmitter

Pressure Transmitter Series TST Pressure Range bar, mbar, bar Output Signals ma, V

Differential pressure gauge with switch contacts For the process industry Models DPGS43HP.1x0, high overload safety up to 40, 100, 250 or 400 bar

Absolute pressure gauge with switch contacts For the process industry, NS 100 and 160 Models , and

Differential pressure gauge For the process industry Models , , high overload safety up to 40, 100 or 400 bar

General Specifications

SITRANS P measuring instruments for pressure

Flap-Type Flow Meter Prall

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Differential pressure gauges with Bourdon tube

GA 24 Heavy-duty variable area flowmeter

Screw-in Thermocouples

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40TA, with component testing

Differential pressure gauge with micro switches With integrated working pressure indication (DELTA-comb) Model DPGS40

Type 2511/12. Type Type 2030 Cable plug. ASI cable plug. Dosing control. General technical data Orifice Type 6518

3/2-, 5/2- and 5/3-way Solenoid Valves for process pneumatics

Differential pressure gauge with output signal With integrated working pressure indication (DELTA-trans) Model DPGT40

Data sheet * * Fill Level Limiter. Application

Differential-Pressure Flow Meter

KINAX SR 709 Transmitter for Position Feedback

Differential pressure gauge with switch contacts For the process industry, all-metal media chamber Models DPGS43.100, DPGS43.160

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

SATRON VT Pressure Transmitter

DMK 331P DMK 331P. Industrial Pressure Transmitter. Pressure Ports With Flush Welded Stainless Steel Diaphragm. Pressure Transmitter.

DMP 331. Industrial Pressure Transmitter for Low Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

JUMO dtrans p20. Process pressure transmitter. Brief description. Special features. Block diagram. Approvals/approval marks (see "Technical data")

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

JUMO dtrans p02. Pressure transmitter. General application. Approvals/marks of conformity. Data Sheet Page 1/6. II 1/2G Ex ia IIC T6 Ga/Gb

Mechatronic pressure measurement. Applications. Special features. Description

Metal tube flowmeters. Series SC250. Metal Tube Flow Meters. Series SC250. Variable area flowmeter for liquids, gases and steam

Metal tube variable area flowmeter for gases, liquids and steam

INLINE Flow sensor for hazardous area II 1 G/D - II 2 D - II 3 GD - I M1

DPT 200. Differential Pressure Transmitter for Process Industry with HART -Communication. accuracy according to IEC 60770: 0.

DMP 333. Industrial Pressure Transmitter For High Pressure DRUCK & TEMPERATUR LEITENBERGER GMBH. Stainless Steel Sensor

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Mechanical pressure gauges

General Specifications

Series V2001 Valves Type 3531 Globe Valve for Heat Transfer Oil with pneumatic or electric actuator

Glass tube flowmeters Series 6000 Variable area flowmeter for liquids and gases

Series V2001 Valves Type 3535 Three-way Valve for Heat Transfer Oil with pneumatic or electric actuator

Pressure transmitter JUMO dtrans p02

PRESSURE TRANSMITTER PYRP-28 INDUSTRIAL & INTRINSICALLY SAFE PRESSURE TRANSMITTER PRESSURE TRANSMITTER

BFS-10-O G1/4: BFS-10-O G1/2: BFS-10-O G1: Contact rating: BFS-10-O G1/4

Material pressure (bar) (Cv (US) kv x 1,2 Seat. N/en

General Specifications

Solenoid Valves Type 3963

Differential pressure switch Model DPS40

Technical Datasheet. Differential Pressure Gauge Diaphragm DG Range. Performance characteristics. Product applications. How can we help you?

LMK 387. Stainless Steel Probe. Ceramic Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO

Differential Pressure Gauges (701P Series)

Magnetic float switch For vertical installation Model FLS (models with Ex approval: 60, AL-ADF)

Series 430 Type 3430 Pneumatic Indicating Controller for Temperature with Capillary Sensor Type 3432 Controller Station Type 3436 Transmitter Module

Pressure Transmitters

Electropneumatic Converters i/p Converters Type 6111 Mounting and Operating Instructions EB 6111 EN

Differential pressure gauge with output signal For the process industry, all-metal media chamber Models DPGT and DPGT43.160

Volumeter TRZ 03-K PRODUCT INFORMATION. Reliable Measurements of Gas

Design and applications

Flow switches Series AD/VH

Pressure transmitter PASCAL CV4

k Applications Bourdon tube pressure gauge with switch contacts For the process industry, NS 100 and 160 Models PGS and PGS23.

THE EXPERT IN LEVEL AND FLOW

Oriflow. Compact Orifice with HART communication. Operating instructions. A-EN RevC Latest Mod von 16

NAMUR FLANGE: With integrated exhaust air recirculation Ordering information

SATRON VVFe Pressure Transmitter

System 6000 Electropneumatic Converter for Direct Current Signals Type 6116 i/p Converter

Electronic Pressure Switches

Type 3761 Pneumatic or Electropneumatic Positioner for Rotary Actuators. Fig. 1 Type 3761 Positioner. Mounting and Operating Instructions EB 8386 EN

Pressure transmitter COMPACT ECOnomic

3/2-way Rocker Solenoid Valve for pneumatic systems

KINAX SR 709 Transmitter for position feedback

Differential pressure transmitter PASCAL Ci4 Delta P

Pneumatic control unit for decentralized automation of ELEMENT process valves

Level Measurement based on Archimedes Principle. Device Description

Smart Pressure Transmitter

Resistance Thermometers Model TR217, with Spring-Loaded Probe Tip

Transcription:

DA03 Differential Pressure Gauge / Differential Pressure Gauge and Switch Models for Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Application The DA03 serves as indicator of differential pressure. Follow mounting instructions in accordance to application. Differential Pressure Gauge without Switching Contacts (Non-electrical Device) DA03##########0A Explosion-hazardous areas zone 1 and 2, as well as 21 and 22, endangerment by gases and dry dusts. II 2 GD c 95 C IP65 19.3.07 DB_GB_DA03_ATEX.fm Differential Pressure Gauge with Built-in Contacts DA03##########1B Simple electrical equipment per EN50020 para. 5.4 for usage in explosion-hazardous areas zone 1 and 2. II 2 G c 95 C IP65 Differential Pressure Gauge with Built-in Inductive Proximity Switch DA03##########1C Explosion-hazardous areas zone 1 and 2, as well as 21 and 22, endangerment by gases and dry dusts. II 2 GD c 95 C IP65 EC-type approval of inductive proximity switch PTB 99 ATEX 2219X II 2 G EEx ia IIC T6 and Zelm 03 ATEX 0128 X II 1 D Ex ia D 20T.. C Differential Pressure Gauge with Built-in Capacitive Electrical Position Transducer (KINAX 3W2) DA03##########2D Explosion-hazardous areas zone 1 and 2, endangerment by gases. II 2 G c 95 C IP65 EC-type approval of built-in capacitive electrical position transducer PTB 97 ATEX 2271 KINAX 3W2 708... II 2 G EEx ia IIC T6 Functional Scheme 7 3 4 6 5 1. Connecting rod 2. O-Ring, differential overpressure protection 3. Sensing diaphragm 4. Pointer mechanism 5. Lever 6. Link 7. Pressure transfer liquid 1 2

Specifications Mounting Options and Accessories Materials Gemeral Measuring ranges Nominal pressure rating Accuracy Max. differential overpressure Indicator Operating temperature Temperature coefficient Zero adjustment Protection class Pressure chambers Pressure connections Purge ports Type R Pressure chamber (wetted part) Diaphragm (wetted part) Type H (1) Pressure chamber (wetted part) Diaphragm (wetted part) Intermediate plate Dial mechanism, gauge housing Dial window Dial scale and pointer O-ring gasket Electrical accessories Liquid filling Reference pointer Peak registering pointer Options (on special order) Accessories Pressure connections Wall mounting (Type W ) Pipe mounting (Type R ) Panel mounting (2) Panel mounting with front cover ring and support (3) 0...40 mbar to 0...25 bar (see Ordering Code) 40 bar or 100 bar (max. static pressure) ± 1.6% of span Safe up to max. static pressure; in either direction Circular dial type, 100 mm or 160 mm diameter Ambient: -20 C to +60 C Media: see advice given in Assignment in Explosion-hazardous Areas, resp. device Approx. 0.3% / 10 C Screw through hole on top of dial housing. ±25% FS. IP 65 per DIN EN 60529 Smooth internal surfaces without recesses; flush sensing diaphragms DIN 19213 connecting flanges with 2x G½ (F) threaded sockets. Various bite type ferrule connectors (see Ordering Code) 2x G 1/8 (F) threaded sockets, in flanged pressure chamber casing; screw plugs fitted Stainless steel 1.4404 ( ANSI 316L) Ranges 400 mbar: stainless steel 1.4571 Ranges 0.6 bar: DURATHERM (stainless steel) Hastelloy C4 Ranges 2.5 bar: Hastelloy C 276 Ranges 4 bar: Standard diaphragm with separating foil made from Hastelloy C 276 Caution: Models with separating foil are unsuitable for vacuum application. Aluminium alloy (AlMgSiPb); HART-COAT Stainless steel 1.4301 Laminated safety glass Aluminium Viton (FKM, flourocarbon elastomere) Limit signalling contacts: delayed action / magnet actuated switch type / non-contact proximity type limit detector. Pointer rotation transducer: capacitance type, with output signal proportional to the pointer position (uses deeper gauge housing: see Dimensions) For details of electrical accessories, see Data Sheet KE. For application in explosion-hazardous areas note version restrictions (see Ordering Code)! For operating conditions involving vibration, pressure fluctuations, and/or moisture condensation inside, the gauge can be supplied with glycerine filling. Adjustable pointer for visual marking of limit / reference value. Separate pointer without spring, friction holding: dragged by the measuring pointer as the measured value increases. Stays put when the measuring pointer recedes, thereby registering peak value. Manual re-setting. Special materials: PTFE coated gaskets (compatibility of medium) Special dial scales; Housing of 1.4571 stainless steel Direct fitting 3-spindle blocking/equalizing valves unit. Installs directly on the gauge flanges. Rating PN 100; size DN 5; stainless steel 1.4571 (Model DZ 36-00LV0300) Process pipe connection to be erected by using bite type ferrule connectors or direct fitting of pipe into G½ F thread. Make sure that the connection is firmly sealed. With mounting plate on back of instrument With mounting parts for vertical or horizontal mounting on 2 pipes Due to the instruments heavy weight the small measuring cell only is suitable for direct panel mounting: measuring ranges 0.6 bar, dial ND 100, without contacts or transmitters. The instrument factory prepared for panel mounting and the necessary mounting parts may be ordered with code T. All models may be fitted with a costumer made support construction and the front cover ring to be used for panel mounting (Ordering Code G ).

Differential Pressure Gauge without Switching Contacts (non-electrical device) Ordering Code DA03 # # # # # # # # # #0A Range of Applications: Explosion-hazardous areas zone 1 and 2, as well as 21 and 22, endangerment by gases and dry dusts. Permissible temperatures: Max. surface temperature of 95 C was calculated without settled dust and without safety factor. Perm. ambient temperature -20 C up to +60 C. Perm. medium temperature within differential pressure gauge < 85 C. Caution! When used with gasous media temperature of device might increase due to compression temperature. In such cases pressure variation speed resp. perm. media temperature must be reduced. Note: During pressure variation between 10% and 90% of FS and a pulsation rate < 0.06 Hz temperature raises <10K. To avoid additional heating of instrument they must not be used in direct sunshine! Regarding explosion protection for non-electrial part of device applied standards EN13463-1, EN13463-5 and EN50281-1-2 are met. Documents are deposited at TÜV-Nord-Cert. Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Declaration CE II 2 GD c 95 C IP65

Differential Pressure Gauge with built-in contacts Ordering Code DA03 # # # # # # # # # #1B with built-in contacts KE# # M # # 0 D 4H2 Range of Applications: Simple electrical equipment per EN50020 para. 5.4 for usage in explosion-hazardous areas zone 1 and 2 Permissible temperatures: Max. surface temperature of 95 C was calculated without settled dust and without safety factor. Perm. ambient temperature -20 C up to +60 C. Perm. medium temperature within differential pressure gauge < 85 C. Caution! When used with gasous media temperature of device might increase due to compression temperature. In such cases pressure variation speed resp. perm. media temperature must be reduced. Note: During pressure variation between 10% and 90% of FS and a pulsation rate < 0.06 Hz temperature raises <10K. To avoid additional heating of instrument they must not be used in direct sunshine! Regarding explosion protection for non-electrial part of device applied standards EN13463-1, EN13463-5 and EN50281-1-2 are met. Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Simple electrical equipment must meet requirements of EN50020 para. 5.4 and applicable requisitions of EN50014. The devices are not marked regarding electrical parts. For application in explosion-hazardous areas the devices need to be connected to certified intrinsically safe circuits: max. voltage U max = 30 V max. current I max = 200 ma max. power P max = 800 mw Device specifications (per contact): max. internal capacity C i max = 60 pf max. internal inductivity L i max = 4 µh Documents regarding mechanical parts are deposited at TÜV-Nord-Cert. Declaration CE II 2 G c 95 C IP65 Recommended isolating switches: MTL 5011B (1-channel, for contacts / inductive proximity switch, Operating voltage 20-35 V DC) MTL 5015 (2-channel, for contacts / inductive proximity switch, Operating voltage 20-35 V DC) KFA6-SR2-Ex1.W (1-channel, for contacts / inductive proximity switch, Operating voltage 230 V AC) KFA6-SR2-Ex2.W (2-channel, for contacts / inductive proximity switch, Operating voltage 230 V AC)

Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Differential Pressure Gauge with built-in inductive proximity switch Ordering Code DA03 # # # # # # # # # #1C with built-in inductive proximity switch KE# #I# # 0C 0 H 2 Range of Applications: Explosion-hazardous areas zone 1 and 2, as well as 21 and 22, endangerment by gases and dry dusts Permissible temperatures: Max. surface temperature of 95 C was calculated without settled dust and without safety factor. Perm. ambient temperature -20 C up to +60 C. Perm. medium temperature within differential pressure gauge < 85 C. Caution! When used with gasous media temperature of device might increase due to compression temperature. In such cases pressure variation speed resp. perm. media temperature must be reduced. Note: During pressure variation between 10% and 90% of FS and a pulsation rate < 0.06 Hz temperature raises <10K. To avoid additional heating of instrument they must not be used in direct sunshine! EC-type approval of inductive proximity switches: PTB 99 ATEX 2219 X and Zelm 03 ATEX 0128 X The type of inbuilt inductive proximity switch is declared on type plate / connection scheme. IP protection class of housing: IP65 acc. to EN60529. For application in explosion-hazardous areas the devices need to be connected to certified intrinsically safe circuits: max. voltage U max = 16 V max. current I max = 25 ma max. power P max = 64 mw Device specifications (per contact): max. internal capacity C i max = 30 pf max. internal inductivity L i max = 100 µh Permissible limit values of U i, Ι i and P i of intrinsically safe circuits depend on type of inductive proximity switch. See respective EC-type approvals. Regarding explosion protection for non-electrial part of device applied standards EN13463-1, EN13463-5 and EN50281-1-2 are met. Documents regarding mechanical parts are deposited at TÜV-Nord-Cert. Declaration CE II 2 GD c 95 C IP65 Built-in inductive proximity switch PTB 99 ATEX 2219X II 2 G EEx ia IIC T6 Zelm 03 ATEX 0128 X II 1 D Ex ia D 20T.. C Recommended isolating switches: MTL 5011B (1-channel, for contacts / inductive proximity switch, Operating voltage 20-35 V DC) MTL 5015 (2-channel, for contacts / inductive proximity switch, Operating voltage 20-35 V DC) KFA6-SR2-Ex1.W (1-channel, for contacts / inductive proximity switch, Operating voltage 230 V AC) KFA6-SR2-Ex2.W (2-channel, for contacts / inductive proximity switch, Operating voltage 230 V AC)

Assignment in Explosion-hazardous Areas per Directive 94/9/EC (ATEX) Differential Pressure Gauge with built-in capacitive electrical position transducer (KINAX 3W2)) Ordering Code DA03 # # # # # # # # # #2D with built-in capacitive electrical position transducer KE0905#90000 Range of Applications: Explosion-hazardous areas zone 1 and 2 endangerment by gases Permissible temperatures: Max. surface temperature of 95 C was calculated without settled dust and without safety factor. Perm. ambient temperature -20 C up to +60 C. Perm. medium temperature within differential pressure gauge < 85 C. Caution! When used with gasous media temperature of device might increase due to compression temperature. In such cases pressure variation speed resp. perm. media temperature must be reduced. Note: During pressure variation between 10% and 90% of FS and a pulsation rate < 0.06 Hz temperature raises <10K. To avoid additional heating of instrument they must not be used in direct sunshine! EC-type approval of built-in capacitive electrical position transducer: PTB 97 ATEX 2271 KINAX 3W2 708... Type of built-in capacitive electrical position transducer is declared on type plate / connection scheme. IP protection class of housing: IP65 acc. to EN60529. For application in explosion-hazardous areas the devices need to be connected to certified intrinsically safe circuits: max. voltage U max = 30 V max. current I max = 160 ma max. power P max = 1mW Device specifications (per contact): max. internal capacity C i max = 10 pf max. internal inductivity L i max = 0 µh Permissible limit values of U i, Ι i and P i of intrinsically safe circuits depend on type of inductive proximity switch. See respective EC-type approvals. Regarding explosion protection for non-electrial part of device applied standards EN13463-1, EN13463-5 and EN50281-1-2 are met. Documents regarding mechanical parts are deposited at TÜV-Nord-Cert. Declaration CE II 2 G c 95 C IP65 Built-in capacitive electrical position transducer PTB 97 ATEX 2271 II 2 G EEx ia IIC T6 Recommended supply device: MTL 5041 Operating voltage 20-35 V DC

Dimensions (all units in mm unless stated otherwise) for ranges 40...400 mbar connection M20 x 1.5 152 132 120 (with built-in contacts) 108 Ø9 rinsing and venting connection 60 100 141 80 239.5 (with built-in contacts) 141 193,5 NG160 = Ø161 2" pipe parts for pipe mounting 65 Drilling plan for mounting plate 60 G1/2 41,3 Ø9 for ranges 0.6...25 bar 7/16 UNF 90 (with built-in contacts) 54 130 110 114 80 Ø9 75 93 184.5 (with built-in contacts) 93 145.5 NG100=Ø101 / NG160=Ø161 132 Drilling plan for mounting plate Bohrbild Montageplatte Ø9 connection M20 x 1.5 110 Three spindle blocking / equalising valves unit DZ 36-00 LV 0300 fits directly onto the DIN 19209 flanges Panel mounting with customer prepared support (Ordering Code G ) Panel 2 ~145 ~105 Cutting ring connection 70 Instrument NG160 Panel cutout Ø164 Ø178 Ø5.8-3x120 Ø192 LK 54 108 (Fitting dimension) ~147 41 M10 Process Drilling Ø4.8 Panel 2 Support 120 Panel mounting accessories only for bar ranges (Ordering code T ) 75 NG100 / NG160 Panel cutout Ø104 / Ø164 LK Ø116 / Ø178 Ø132 / Ø192 54

Ordering Code Differential Pressure Gauge DA 03 Range 0... 40 mbar... > 5 7 0... 60 mbar... > 5 8 0... 100 mbar... > 5 9 0... 160 mbar... > 6 0 0... 250 mbar... > 8 2 0... 400 mbar... > 8 3-40... 60 mbar... > 7 0-60... 100 mbar... > 7 2-100... 150 mbar... > 7 4-150... 250 mbar... > 7 6 0... 0.6 bar... > 0 1 0... 1 bar... > 0 2 0... 1.6 bar... > 0 3 0... 2.5 bar... > 0 4 0... 4 bar... > 0 5 0... 6 bar... > 0 6 0... 10 bar... > 0 7 0... 16 bar... > 0 8 0... 25 bar... > 0 9-1... 0.6 bar... > 3 2-1... 1.5 bar... > 3 3-1... 3 bar... > 3 4-1... 5 bar... > 3 5 Nominal Pressure Rating 40 bar... > H 100 bar... > L Measuring System Material Pressure chamber of Hastelloy C4 / Sensing diaphragm of Hastelloy C276 (1)... > Pressure chamber of chrome-nickel-steel 1.4404 / AISI 316 L / Standard sensing diaphragm... > H R Pressure Connections DIN 19213 flanges with threaded sockets: 2x G1/2 (F)... > 0 3 Threaded connectors: 2x NPT 1/4-18 (F)... > 0 4 Threaded connectors: 2x NPT 1/2-14 (F)... > 0 5 Threaded connectors: 2x G1/2 (M) stainless steel... > 1 3 Threaded connectors: 2x NPT 1/4-18 (M) stainless steel... > 1 4 Threaded connectors: 2x NPT 1/2-14 (M) stainless steel... > 1 5 Bite type ferrule connectors (1.4571) for 12 mm tube... > 2 7 Dial Size Bayonet ring case ø 100 mm (only for ranges 0.6 bar) 1.4301... > Bayonet ring case ø 160 mm, 1.4301... > L M Mounting Wall mounting (Standard)... > Pipe mounting... > Panel mounting (only for bar ranges) (2)... > Front cover ring for panel mounting (3)... > W R T G Dial Liquid Filling Without liquid filling... > 0 Dial with liquid filling: glycerine (only for devices without contacts)... > 1 Dial with liquid filling: compatible with built-in inductive contacts (Silicone oil)... > 4 Dial with liquid filling (Silicone oil)... > 5 Additional Pointer Without additional pointer 0 Adjustable reference pointer... > 1 Peak registering pointer, resettable (only for ranges 60 mbar)... > 2 Signalling Accessories: Contacts / Transmitters Without contacts / transmitter... > 0 Built-in contacts per Data Sheet KE... (ranges 100 mbar)... > 1 Built-in capacitive electrical position transducer per Data Sheet KE09 (ranges 100 mbar)... > 2 Built-in contacts with plug connection (power plant model)... > 5 Built-in resistance type remote sensors acc. to data sheet KE07 (ranges 100 mbar)... > 6 Explosion Protection / Contacts Standard... > 0 Non-electrical device (without switching contacts) II2 GD c 95 C IP65... > A Device with switching contacts (simple electrical equipment per EN50020 para. 5.4 ) Built-in contacts, per Data Sheet KE... (ranges 100 mbar) II2 G c 95 C IP65... > B (4) Device with switching contacts (inductive proximity switch) Built-in contacts, per Data Sheet KE... (ranges 100 mbar) II2 GD c 95 C IP65... > C (4) Device with built-in capacitive electrical position transducer KINAX 3W2 708-226D0 oder KINAX 3W2 708-226E0... (ranges 100 mbar) II2 G c 95 C IP65... > D (4) (1), (2), (3) see Specifications (4) Version restrictions B: KE##M##0D4H2 C: KE##I##0C0H2 D: KE0905#90000 Technische Änderungen vorbehalten Subject to change without notice Changements techniques sous réserve Fischer Mess- und Regeltechnik GmbH Bielefelder Str. 37a D-32107 Bad Salzuflen Tel. +49 5222 9740 Fax +49 5222 7170 email: info@fischermesstechnik.de www.fischermesstechnik.de