QLS+ RC Series NEW QUALITY & LEVEL SENSOR (QLS+): ALL IN ONE SOLUTION FOR DIESEL EXHAUST FLUID (DEF) / ADBLUE TANK

Similar documents
QLS-PL Series In Tank Urea Sensor

FPS5851DLC4 Urea Quality Sensor - Provisional Specification

FPS2851ULC4 Urea Quality Sensor

FPS2851ULC4 Urea Quality Sensor

HM1520LF Relative Humidity Module

The concentration measurement is based on measuring the speed of sound in the liquid. The speed of sound is measured by generating an ultrasonic signa

Mountable with O-ring seal Urea level ±0.5% Accuracy Urea pressure ±2.0 Total Error Band Air Brakes Corrosive fluid measurement for E&V applications

EB100 High Accuracy Miniature Pressure Transducer

Encoder WDGA 58V CAN SAE J1939

FS20 Low Force Compression Load Cell

MS52XX SMD Pressure Sensor

MS5201-XD SMD Gage Pressure Sensor

DIAGNOSTIC REPORT. Vehicle Components. Engine Cummins 15.0L ISX B0 BAC Brakes Bendix EC-60 Advanced ABS P

MS52XX SMD Pressure Sensor

DIAGNOSTIC REPORT. Vehicle Components. Speed Brakes Bendix EC-60 Advanced ABS BB40904, L

Vehicle Components. Vehicle Key Data Points

Additional Instructions MHC-1 J1939

J1939 Fault Codes G04.02

Temperature transmitter CAN SAE J1939 DST T92C

GENERIC ENGINE MONITOR 4

ALM-Inline. Accurate Lambda Meter V1.1.2 COPY RIGHTS ECOTRONS LLC ALL RIGHTS RESERVED.

Testing Expo Comparison of OBD II Scan-Tool diagnostics for light-duty vehicles and heavy-duty trucks. Peter Stoß Director RA Automotive

SSI Technologies - Application Note AT-AN2 Acu-Trac NEMA 4 Liquid Level Sensor Product Overview

DIAGNOSTIC REPORT. Vehicle Components. Vehicle Key Data Points

CUMMINS ENGINE DIAGNOSTIC CODES

FEATURES AND BENEFITS

DASH RETRIEVED FAULT CODES C ONVENTIONAL FS65 SAF T LINER C2, C2E H YBRID SAF T LINER HDX, HD, ER SAF T LINER EF, EFX A LL Y EARS

ORDERING INFORMATION # of Ports Pressure Type Device Device Name Options

DIAGNOSTIC REPORT. Vehicle Components. Vehicle Key Data Points

ABS motorcycle braking chip

ABS motorcycle braking chip

Automotive Sensor Products

MS4515 SPECIFICATIONS FEATURES APPLICATIONS

General Presentation

MS4525 SPECIFICATIONS

CANBUS G. Up to mm ( in.) < ± 0.01% of full stroke or ± 0.04 mm ( in.), whichever is greater*

Series 7000 Torque Sensor for PTO-shafts

CTE7000 / CTU7000 Series Miniature pressure transmitters

SAE J1939 CAN compatible sensors for hydraulic system monitoring of flow, pressure and temperature on pumps, valves and hydrostatic transmissions

Sensors for Wind Turbines

CTE9000 / CTU9000 Series OEM pressure transmitters for industrial media

Series 7000 Torque Sensor for PTO-shafts

Fleetguard AdBlue Packaged & Bulk Supply CHEMICALS

CANADA SENSORS TECHNOLOGY INC.

Arduino-based OBD-II Interface and Data Logger. CS 497 Independent Study Ryan Miller Advisor: Prof. Douglas Comer April 26, 2011

Pressure transmitter CAN SAE J1939 DST P92C

THE RIGHT TECHNOLOGY. The Best Route to Euro 4

PMF4000 Series DESCRIPTION FEATURES APPLICATIONS MAXIMUM RATINGS MASS AIR FLOW SENSOR

AVL PLU 131U FLOW METER

Integrated Silicon Pressure Sensor for Manifold Absolute Pressure Applications On-Chip Signal Conditioned, Temperature Compensated and Calibrated

MAN TRUCK FAULT CODES ENGINE CONTROL UNITS (EDC7)

EGQ 212: Duct transducer, CO 2 and temperature

UENR4504 January Troubleshooting. 854F-E34TA Industrial Engine. JU (Engine) This document has been printed from SPI2.

force/torque solutions by sensor type

Intelligent Positioner

Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM

SSI Technologies MediaSensor

Setup and Configuration Guide Universal Switch Interface

CTE8000 / CTU8000 Series

Additions, Revisions, or Updates

Optidew Vision Optical Dew-Point Meter

Is Now Part of. To learn more about ON Semiconductor, please visit our website at

KA317M. 3-Terminal 0.5A Positive Adjustable Regulator. Features. Description. Internal Block Diagram.

1/4" Square Single-Turn Cermet Sealed Trimmer

NTC Thermistors, 2-Point Micro Chip Sensor Insulated Leads

1/4" Square Single-Turn Cermet Sealed Trimmer

ELM327 OBD to RS232 Interpreter

OIS21C. Optical smart sensor for hydraulic cylinders. General Description. Features. Applications. Pin Functions. Ordering Information

NTC Thermistors, Flex Foil Sensors

Sensors for Wind Turbines

BTE2000 / PTE2000 Series Precision stainless steel pressure transmitters

CAN-bus. Scanning of diagnostic trouble codes via OBD-II connector

SentryGOLD Fully-Automated Fuel Management System

Diagnostic Report. Monitor Status Report. Page 1 of 12. Date: 12/18/2016 9:17:03 PM

Aluminum Capacitors Standard C Snap-In

Vehicle Components. (High)/J1587 (Low) Intersection Preemption Emitter. Mack Aftertreatment Control Module

R A, 80V Microstepping Driver The PowerHouse

Temposonics. Magnetostrictive, Absolute, Non-contact Linear-Position Sensors. R-Series Models RP and RH DeviceNet Output.

Trucks. Group 28 MID 128 Fault Code Guide 2007 Emissions VN, VHD VERSION2, VT PV

ZT-USB Series User Manual

Prism PI Intelligent features offer advanced performance

ACT V/1.5A Backup Battery Pack Manager FEATURES APPLICATIONS GENERAL DESCRIPTION. Rev 0, 06-Nov-13 Product Brief

Automotive, Sulfur Resistant Lead (Pb)-Free Thick Film, Rectangular Chip Resistors

LV8804FV. Fan Motor Driver. Overview The LV8804FV is a motor driver for PC and server fans. Feature Direct PWM 3-phase sensorless motor driver

TND337/D. The LIN Bus in Modern Automotive Headlamp Systems TECHNICAL NOTE

Service Bulletin Buses

Aluminum Capacitors Standard - 85 C Snap-In

CUMMINS FAULT CODE: 1239 PID: SPN: 2623 FMI: 3/3 LAMP: AMBER

Part Number AEM 4-CH WIDEBAND UEGO CONTROLLER

new products R02 W02 STAG-4 QBOX PLUS 200 GoFast

ANALOG. PARAMETER SPECIFICATION Measured Variable: Displacement, Velocity (magnitude only) 16 bit or mm, whichever is greater

VariStroke II Electro hydraulic Actuator

Flow measurement FlexFlow PF20H Hygienic flow sensor

Aluminum Capacitors, Power High Ripple Current, Screw Terminals

SPN 4364 (ACM)(EPA10); SPN 4364 (ACM)(GHG14) January Publication Number / Title Platform Section Title Change SPN 4364/FMI 18 - EPA10

Is Now Part of. To learn more about ON Semiconductor, please visit our website at

Pressure transducer DMU 01K Compact version

Millivolt Output Pressure Sensors

Steering units by SKF. By-wire technology for improved vehicle efficiency and performance

FORCE SENSORS FORCE SENSORS

Transcription:

NEW QUALITY & LEVEL SENSOR (QLS+): ALL IN ONE SOLUTION FOR DIESEL EXHAUST FLUID () / ADBLUE TANK / AdBlue level o Continuous measurement based on Magneto Resistive (MR) Technology / AdBlue temperature / AdBlue quality o Urea concentration o Detection of unauthorized fluids / AdBlue suction line (with integrated filter) / AdBlue return Tank thawing (using engine cooling system) Tank vent Fully integrated sensor and processing electronics provide a solid state sensor for in tank urea quality and level monitoring. Factory calibrated in compliance with DIN70070 / ISO 22241 standards. Sensor design compliant to: Cummins AEBs 21.112 and 21.79 Data output compliant to: SAE J1939 CAN 2.0A or CAN 2.0B Cummins AEBs 15.139, 15.140, 15.141 and 15.149 Close-up on the Urea Quality Sensor (concentration, temperature and fluid type) 1/8

DESCRIPTION The new Measurement Specialties / AdBlue Quality & Level Sensor (QLS+) product portfolio is designed to integrate and operate within a broad range of / AdBlue tank configurations. In particular, MEAS can customize the QLS+ assembly to match any tank design while providing robust / AdBlue heating and accurately performing / AdBlue liquid level, temperature and quality measurements. The high performance / AdBlue level measurement relies on our solid state Magneto Resistive (MR) sensor chips which are qualified to automotive performance standards and used for critical component linear position measurements. The Urea Quality Sensor (UQS), which is highly integrated within the / AdBlue QLS+ assembly, directly and simultaneously measures the chemical properties of liquids in the / AdBlue tank to determine the presence and concentration of urea in / AdBlue or contaminated fluids. Relying on our patented near infrared (NIR) optical sensor technology, the UQS measurement of urea concentration helps ensure that the urea concentration and its quality assist Selective Catalytic Reduction (SCR) system in effectively reducing NOx to regulated emission standards. The two integrated temperature sensors (one in the UQS and one on the level board) provide a thermal mapping of the suction area. The QLS+ is a smart system and important tool for meeting regulated OBD compliance to confirm urea presence and concentration and security signal communication. A universal digital CAN J1939 compliant protocol provides easy to connect interface to main control systems (i.e., ECM, SCR feed control, OBD bus). A simple 4 pins connector allows cost effective mounting options. FEATURES High reliability and long term stability Optimized for OEM specifications Urea resistant DIN7070/ISO22241 In-tank mounting APPLICATIONS Diesel Engines Passenger Vehicles Buses & Trucks Commercial On and Off Highway Vehicles Freezing resistant Range of sizes to suit your application High reliability Magneto Resistive technology Urea feed and return in the header Integrated filter 2/8

PERFORMANCE SPECIFICATIONS MAXIMUM RATINGS Ratings Symbol Value Unit Supply voltage (peak) Vcc 36 Vdc Environment Operating Temperature * Te -40 to +105 C Fluid Operating Temperature Tf -40 to +85 C Storage Temperature Tstg -40 to +90 C Input current @ 12 VDC (in rush) Ipk 600 (t<200ms) ma Vibration (peak) 15 Grms Peak conditions: less than 10% of the operating time. * Environment Operating Temperature: Service temperature range at which the sensor and its electronics can operate securely METROLOGICAL CHARACTERISTICS Measurement ranges QLS+ Symbol Min Typ Max Unit Urea concentration %urea 0 32.5 62.5 %mass Response time urea concentration sensing @ 25 C <20 120 s Urea concentration accuracy (in the 0-40% range and 0 +60 C range) -2 +2 %mass Urea concentration accuracy (out of the previous described range) -3 +3 %mass / AdBlue fluid temperature * T -11 70 C Other fluid temperature ** T -40 85 C Response time temperature sensing @ 25 C <20 s Temperature accuracy T +-1 C Response time urea level sensing @ 25 C t <20 s / AdBlue level sensing resolution*** 0.2 mm * / AdBlue fluids classically freeze at temperature inferior to -11 C and quickly degrade at temperatures superior to 40 C. ** Temperature sensor is capable within the -40 to 125 C range with 1 C accuracy. *** Accuracy +/-3mm @ 25 C and +/-4mm @ other temperatures ELECTRICAL CHARACTERISTICS (@Vcc=12 Vdc, ambient temperature) Electrical characteristics Symbol Min Typ 1 Typ 2 Max Unit Supply Voltage VBatt 9 12 24 36 Vdc Supply Current @ VBatt (steady state) Iavg 80 70 50 36 ma 3/8

CONNECTING & MECHANICAL PACKAGING LEVEL AND PICK UP UNIT Mounting Vertical Housing Material Stainless Steel / Rubber Float Material Buna N Fitting 90mm Ø x 33.5mmn with band clamp Level, heating and pick- up tubes Stainless Steel 316L Filter Gradient depth media Filter geometry 70 µm (Optional: 40µm) Sealing Components Rubber Header Connection Type Deutsch DT04-4P or other IP Rating IP 67 4/8

BLOCK DIAGRAM 5/8

TRANSMISSION DATA CAN FRAME DESCRIPTION J1939 STANDARDS Baud rate detection: 250Kbit/s or 500Kbit/s or auto baudrate detection PGN 64923 is related to catalyst reagent fluid properties: Aftertreatment Information Aftertreatment 1 Temperature 2 Aftertreatment 1 Concentration Aftertreatment 1 Temperature 2 Preliminary FMI Aftertreatment 1 Properties Preliminary FMI Aftertreatment 1 Property PGN SPN Byte, bit position Length Data range Min Max 64923 3515 1,1 8-40 C 210 C 64923 3516 2,1 8 0% 62,5% 64923 3519 4,1 5 0 31 64923 3520 5,1 5 0 31 64923 3521 6,1 4 0 15 ENCODING 1 C/bit, -40 C offset 0.25%/bit, 0% offset Refer to FMI Table Refer to FMI Table Refer to Fluid Type Scenarii Rate Source Address 0xA3 PGN 65110 is related to catalyst reagent fluid level: Aftertreatment 1 Tank 1 Information Aftertreatment 1 Tank Level Aftertreatment 1 Tank Temperature Aftertreatment 1 Tank Level 2 Aftertreatment 1 Tank Level Preliminary FMI Aftertreatment 1 Tank 1 Temperature Preliminary FMI PGN SPN Byte, bit position Length Data range Min Max 65110 1761 1.1 8 0% 100% 65110 3031 2.1 8-40 C 210 C ENCODING 0.4%/bit, 0% offset 1 C/bit, -40 C offset Rate 65110 3517 3.1 16 0 Max 0.1mm/bit 65110 3532 5.1 5 0 31 65110 4365 6.1 5 0 31 Refer to FMI Table Refer to FMI Table Source Address 0xA3 PGN 60928 is related to address claim: Arbitrary Address Capable = 0 Industry Group = 0 Function = 45 (Engine Emission After treatment System) Manufacturer Code = 0x0FF (MEAS) Identity Number = Serial Number (21 bits) Following information can be available on request: DM 19 Calibration Information (PGN 54016) Software Identification (PGN 65242) 6/8

FAILURE STATUS AND DIAGNOSTIC & FLUID TYPE SCENARII Failure status and diagnostic of the UQS are defined by SPN 3519 and 3520: Failure Mode SPN 3516 Concentration SPN 3520 Properties FMI SPN 3521 Property SPN 3515 Temp 2 SPN 3519 Temp 2 FMI Aftertreatment 1 Temperature 2 > 125 C 0xFB 31 0xE 125 C 15 Aftertreatment 1 Temperature 2 < -40 C 0xFB 31 0xE -40 C 17 Aftertreatment 1 Temperature 2 Short Circuit 0xFB 31 0xF 0xFE 4 Aftertreatment 1 Temperature 2 Open Circuit 0xFB 31 0xF 0xFE 3 Optical Data Incorrect* 0xFE 2 0xE Aftertreatment 1 Concentration < 0% 0% 17 0xD Aftertreatment 1 Concentration > 62,5% 62,5% 15 0xD UQS Not Detected 0xFE 12 0xF 0xFE 12 No Flag 31 0xD 31 Blank: not impacted by sensor s status *: Optical signal too low or too high Fluid Type Scenarii: Fluid Type SPN 3516 Concentration SPN 3520 Properties FMI SPN 3521 Property Catalyst reagent is diesel 0xFB 31 0x2 Catalyst reagent is proper mixture ( / AdBlue ) 31 0x3 Not able to determine catalyst reagent type X 1 X 2 0xD Error detected with urea reagent type detection X 3 X 4 0xE Not available 0xFB 31 0xF Ice Detected 0xFB 31 0xF Blank: not impacted by sensor s status X 1: 0xFB or not impacted; X 2: 14, 17 or 31; X 3: 0xFB or 0xFE; X 4: 2 or 31 Failure status and diagnostic of the FLS are defined by SPN 3532 and 4365: Failure Mode SPN 3031 Tank Temp SPN 4365 Tank 1 Temp FMI SPN 1761 Tank Level (%) SPN 3517 Tank Level 2 (mm) SPN 3532 Tank Level FMI Aftertreatment 1 Tank Temperature > 125 C 125 C 15 0xFB 0xFB00 31 Aftertreatment 1 Tank Temperature < -40 C -40 C 17 0xFB 0xFB00 31 Aftertreatment 1 Tank Temperature Short 0xFE 4 Circuit Aftertreatment 1 Tank Temperature Open Circuit 0xFE 3 Aftertreatment 1 Tank Level Open Circuit Faulty MR X 5 X 5 3 Aftertreatment 1 Tank Level < 0% 0% 0 mm 17 Aftertreatment 1 Tank Level > 100% 100% Max (mm) 15 Level Data Incorrect** 0xFE 0xFE00 11 Stuck Float 2 No Flag 31 31 Blank: not impacted by sensor s status X 5: Degraded measurement information **: Root cause unknown 7/8

FMI TABLE FMI FMI=2 FMI=3 FMI=4 FMI=11 FMI=12 FMI=15 FMI=17 FMI=31 FMI Description Data erratic, intermittent or incorrect Voltage Above Normal, Or Shorted To High Source Voltage Below Normal, Or Shorted To Low Source Root Cause Not Known Bad intelligent device or component Data Valid But Above Normal Operating Range - Moderately Severe Level Data Valid But Below Normal Operating Range - Moderately Severe Level Condition Exists TECHNICAL CONTACT INFORMATION Measurement Specialties, Inc. 1000 Lucas Way Hampton, VA 23666 Tel: 1-800-555-1551 Fax: 1-757-766-4297 Sales: sales@meas-spec.com Measurement Specialties, Inc. France Impasse Jeanne Benozzi CS 83 163 31027 Toulouse Cedex 3 France Tél: +33 (0) 582 082 200 Fax: +33 (0) 582 082 150 Sales: fluid.sales@meas-spec.com The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assum ed for inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specif ically disclaims any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different applications. All operating parameters must be validated for each customer application by customer s technical experts. Measurement Specialties, Inc. does not convey any license under its patent rights nor the rights of others. 8/8