Breakers and Switches. Tmax XT Moulded-case circuit-breakers Simply extraordinary

Similar documents
SACE Tmax XT. New low voltage moulded-case circuit-breakers up to 250A.

SACE FORMULA New low voltage moulded-case circuit-breakers up to 630 A

Extract of the technical catalogue SACE Tmax XT New low voltage molded-case circuit breakers up to 250A

Electrification Products Price List (`) ABB Authorised Distributor Spot India Group Tel:

Ordering information for XT1, XT2, XT3, XT4 UL/CSA Accessories

Technical catalogue - Preliminary. SACE Tmax XT New low voltage moulded-case circuit-breakers up to 250 A

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

Low Voltage Products Price list. ABB Authorised Dealer R Sanghavi Mercantile Pvt. Ltd.

Kit EST1 6pcs 1SYN450207R0001 Kit EST2 6pcs. 1SYN450202R0001 Kit EST2 8pcs Kit EST3 6pcs. 1SYN450203R0001 Kit EST3 8pcs. 1SYN450209R0001 Kit EST4 6pcs

DPX Magnetic only

US Brochure. Tmax XT Molded case circuit breakers Simply XTraordinary

Authorised Distributor

DPX earth leakage DPX 3 -I earth leakage

Preliminary - 1SDC210003B0201. New Tmax T4-T5. T Generation.

DPX Electronic + earth leakage

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

Tmax. Technical catalogue. Low voltage moulded-case circuit-breakers up to 630 A. Preliminary - 1SDC210004D0203

Tmax. Technical catalogue. Low voltage moulded-case circuit-breakers up to 630 A. Preliminary - 1SDC210004D0202

cor Long Run Experience

1SDC210015B0203. Tmax. T Generation.

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

Technical catalogue January SACE Tmax. T Generation. Low voltage moulded-case circuit-breakers up to 1600 A

DRX 125 Circuit breaker (not adjustable)

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

DPX moulded case circuit breakers

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

The breakers offer thermal-magnetic trip protection according to Z and K characteristics.

DMX 3 -I 2500 switch disconnectors

DRX 100 B/N/H Circuit breaker (not adjustable)


DPX 1600 Electronic release

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

DRX 250 B/N/H Circuit breaker (not adjustable)

DPX 630 Electronic release

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

GENERA TMAX. COMPLETE FREEDOM.

Circuit Breakers Ex9M

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

(p. 47) (p. 155) (p. 155)

Circuit breakers for power distribution A1 Ordering information

SACE Emax 2/ML Low-voltage air circuit breakers for naval applications

3 - Protection components Motor circuit-breakers

Compact NR630. NR100F to NR630F

Protection components

Tmax Molded Case Circuit Breakers

Tmax Molded Case Circuit Breakers

Thermal magnetic and trip-free switches

3.1. Power Breakers, Contactors and Fuses. Contents. Series NRX Low Voltage Power Circuit Breakers. Power Circuit Breakers

01 Spectra Plus - Introduction

ABB molded case circuit breakers

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Prisma ipm Switchboard Air Circuit Breaker (ACB) Moulded-case Circuit Breaker (MCCB) Contactor Power meter

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on left side

Technical catalogue - Edition SACE Emax 2 New low voltage air circuit-breakers

DX³ RCCBs - ID 4P up to 100 A

Miniature Circuit Breakers

The effective choice The benefits of a product with the highest quality standards

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

MS General Information Extended Product Type: MS

Tmax T8. Annex to the technical catalogue. Low voltage moulded-case circuit-breaker up to 3200 A. 1SDC210027D Edition

Phase + Neutral, neutral on right side

Emax DC. Annex to the technical catalogue. Low voltage switch-disconnectors and automatic circuit-breakers for Direct Current Applications

and other modular devices for low voltage installation

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

4 Moulded Case Circuit Breakers XT1 5 Moulded Case Circuit Breakers XT2 - XT4 6 Moulded Case Circuit Breakers T5 - T6

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

Moulded case circuit breakers

UTS400 SELECTION GUIDE CATALOG NUMBERING [PRODUCT SELECTION] UTS400 NT ATU 400A 3P LL LSIS UL MCCB

Wall mounted switchgear

Miniature Circuit Breaker

Breaking and protection devices

TX³ RCCBs 2P up to 100 A

Manual Motor Starters. Meta-MEC

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches. Ex9 Series - M. na.noark-electric.

Technical catalogue. ArTu PB Panelboard 1STC802005D0201

Advanced retrofitting kits solutions for Megamax Megamax Emax 2

PRICING. Multi 9, Compact, Masterpact, Interpact, and Vigirex Circuit Protection Products. Class 600. October 2004

Emax DC. Annex to the technical catalogue. Low voltage switch-disconnectors and automatic circuit-breakers for Direct Current Applications

C60H-DC C curve. Catalogue numbers

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Selection Guide Motor Control Device Solutions

LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

Medium voltage products HD4/R MV gas circuit-breakers for secondary distribution. Power and productivity for a better world TM

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

Electronic circuit breaker EBU10-T

Data Sheet Molded Case Circuit Breakers Molded Case Motor Circuit Protectors Molded Case Switches Ex9 Series - M

Low voltage circuit breakers

Item Code Description Quantity 1SAZ211201R1028 TA25-DU 2,4A THERMAL O/L ( ) 1 1SAZ211201R1043 TA25-DU-11A-THERMAL-OVERLOAD 0

MINIATURE CIRCUIT BREAKER

S200 UL 1077 Series S200. Supplementary protective devices. UL 1077 Series. Miniature. circuit breakers. S200 Supplementary protective devices

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

Transcription:

Breakers and Switches Tmax XT Moulded-case circuit-breakers Simply extraordinary

Tmax XT Simply extraordinary ABB is proud to present you the result of a long and intense research and development project: the new Tmax XT up to 250A - ABB new family of moulded-case circuit-breakers. 2 Tmax XT

XT complete range 4 Tmax XT frames: The small XT1 up to 160A The high-performing XT2 up to 160A The reliable XT3 up to 250A The powerful XT4 up to 250A Tmax XT1 and Tmax XT3 are reliable circuit-breakers for normal requirements. They are available in the three-pole and four-pole versions, both fixed and plug-in type, and with the thermomagnetic trip units. Tmax XT2 and XT4 are technologically advanced circuitbreakers which offer advanced performances and functionalities and can therefore be used on the highest demanding plants. Electronic and thermomagnetic trip units are available. Tmax XT 3

Tmax XT Electrical characteristics Size [A] 160 Poles [N.] 3, 4 Rated service voltage, Ue (AC) 50-60Hz [V] 690 XT1 (DC) [V] 500 Rated insulation voltage, Ui [V] 800 Rated impulse withstand voltage, Uimp [kv] 8 Versions Fixed, Plug-in (1) Breaking capacities according to IEC 60947-2 B C N S H Rated ultimate short-circuit breaking capacity, Icu Icu @ 415V 50-60Hz (AC) [ka] 18 25 36 50 70 Icu @ 690V 50-60Hz (AC) [ka] 3 4 6 8 10 Icu @ 500V (DC) 2 poles in series [ka] Icu @ 500V (DC) 3 poles in series (2) [ka] 18 25 36 50 70 Rated service short-circuit breaking capacity, Ics Ics @ 415V 50-60Hz (AC) [ka] 100% 100% 100% 75% 50% (37,5) Ics @ 690V 50-60Hz (AC) [ka] 100% 100% 75% 50% 50% Ics @ 500V (DC) 2 poles in series [ka] Ics @ 500V (DC) 3 poles in series (2) [ka] 100% 100% 100% 100% 75% Utilisation Category (IEC 60947-2) Reference Standard IEC 60947-2 Isolation behaviour Mounted on DIN Rail DIN EN 50022 Mechanical life [No. Operations] 25000 A [No. Hourly operations] 240 Electrical life @ 415V (AC) [No. Operations] 8000 Dimensions - Fixed (Width x Depth x Height) Total opening time [No. Hourly operations] 120 3 poles [mm] 76,2 x 70 x 130 4 poles [mm] 101,6 x 70 x 130 Circuit-breaker with shunt opening release [ms] 15 Circuit-breaker with undervoltage release [ms] 15 Trip units for power distribution TMD/TMA TMD Ekip LS/I Ekip LSIG Ekip E Trip units for motor protection MF/MA Interchangeable trip units Weight Fixed 3/4 poles [kg] 1,1 / 1,4 (1) XT1 plug-in: In max=125a (2) XT1 500V DC 4 poles in series 4 Tmax XT

XT2 XT3 XT4 160 250 160 / 250 3, 4 3, 4 3, 4 690 690 690 500 500 500 1000 800 1000 8 8 8 Fixed, Plug-in, Withdrawable Fixed, Plug-in Fixed, Plug-in, Withdrawable N S H N S N S H 36 50 70 36 50 36 50 70 10 12 15 5 6 10 12 15 36 50 70 36 50 70 36 50 36 50 70 100% 100% 100% 75% 50% (27) 100% 100% 100% 100% 100% 100% 75% 50% 100% 100% 100% 100% 100% 100% 100% 100% 100% 100% 75% 100% 100% 100% A A A IEC 60947-2 IEC 60947-2 IEC 60947-2 DIN EN 50022 DIN EN 50022 DIN EN 50022 25000 25000 25000 240 240 240 8000 8000 8000 120 120 120 90 x 82,5 x 130 105 x 70 x 150 105 x 82,5 x 160 120 x 82,5 x 130 140 x 70 x 150 140 x 82,5 x 160 15 15 15 15 15 15 1,2 / 1,6 1,7 / 2,1 2,5 / 3,5 Tmax XT 5

Tmax XT Simply extraordinary 2010 Red dot Design Award winner, Tmax XT set up a new technological standard. extraordinary demonstration of ABB innovation capability. extraordinary lastest generation electronics. extraordinary coverage of all plant requirements. extraordinary performances in compact dimensions. extraordinary simplicity of installation and putting into service. extraordinary range of accessories available. Main characteristics Tmax XT1 Frames and In: XT1 up to 160A Poles: 3, 4 Ue: AC 50-60Hz 690V, DC 500V Versions: F, P Icu: XT1 @415V AC: B, C, N, S, H up to 70kA Trip units: TMD Dimensions: (W 3p/4p x D x H) 76,2/101,6x 70 x 130mm XT1D switch-disconnector version Tmax XT2 Frames and In: XT2 up to 160A Poles: 3, 4 Ue: AC 50-60Hz 690V, DC 500V Versions: F, P, W Icu: XT2 @415V AC: N, S, H up to 70kA @690V AC: N, S, H up to 15kA Trip units: TMD/TM MF/MA, Ekip LS/I, Ekip LSIG Interchangeable trip units Dimensions: (W 3p/4p x D x H) 90/120 x 82,5 x 130 mm Tmax XT3 Frames and In: XT3 up to 250A Poles: 3, 4 Ue: AC 50-60Hz 690V, DC 500V Versions: F, P Icu: @415V AC: N, S up to 50kA Trip units: TMD, MA Dimensions: (W 3p/4p x D x H) 105/140 x 70 x 150 mm XT3D switch-disconnector version Tmax XT4 Frames and In: XT4 up to 160A / 250A Poles: 3, 4 Ue: AC 50-60Hz 690V, DC 500V Versions: F, P, W Icu: XT4 @415V AC: N, S, H up to 70kA @690V AC: N, S, H, up to 15kA Trip units: TMD/TMA, MF/MA, Ekip LS/I, Ekip LSIG, Ekip E-LSIG Interchangeable trip units Dimensions: (W 3p/4p x D x H) 105/140 x 82,5 x 160 mm 6 Tmax XT

XT1 160 Thermal magnetic - Fixed (F) - 3 poles - Front terminals 36 ka 50 ka 70 ka 1SDA066799R1 XT1B 160 TMD 16-450 3p F F - 16kA 1SDA066800R1 XT1B 160 TMD 20-450 3p F F - 16kA 1SDA067391R1 XT1C 160 TMD 25-450 3p F F - 25kA 1SDA067411R1 XT1N 160 TMD 32-450 3p F F 1SDA067412R1 XT1N 160 TMD 40-450 3p F F 1SDA067413R1 XT1N 160 TMD 50-500 3p F F 1SDA067431R1 XT1S 160 TMD 50-500 3p F F 1SDA067449R1 XT1H 160 TMD 50-500 3p F F 1SDA067414R1 XT1N 160 TMD 63-630 3p F F 1SDA067432R1 XT1S 160 TMD 63-630 3p F F 1SDA067450R1 XT1H 160 TMD 63-630 3p F F 1SDA067415R1 XT1N 160 TMD 80-800 3p F F 1SDA067433R1 XT1S 160 TMD 80-800 3p F F 1SDA067451R1 XT1H 160 TMD 80-800 3p F F 1SDA067416R1 XT1N 160 TMD 100-1000 3p F F 1SDA067434R1 XT1S 160 TMD 100-1000 3p F F 1SDA067452R1 XT1H 160 TMD 100-1000 3p F F 1SDA067417R1 XT1N 160 TMD 125-1250 3p F F 1SDA067435R1 XT1S 160 TMD 125-1250 3p F F 1SDA067453R1 XT1H 160 TMD 125-1250 3p F F 1SDA067418R1 XT1N 160 TMD 160-1600 3p F F 1SDA067436R1 XT1S 160 TMD 160-1600 3p F F 1SDA067454R1 XT1H 160 TMD 160-1600 3p F F XT2 160 Electronic and Magnetic only - Fixed (F) - 3 poles - Front terminals 36 ka 50 ka 70 ka 1SDA067056R1 XT2N 160 Ekip LS/I In=63A 3p F F 1SDA067765R1 XT2S 160 MA 20 Im=120...280 3p F F 1SDA067859R1 XT2H 160 Ekip LS/I In=63A 3p F F 1SDA067057R1 XT2N 160 Ekip LS/I In=100A 3p F F 1SDA067766R1 XT2S 160 MA 32 Im=192...448 3p F F 1SDA067860R1 XT2H 160 Ekip LS/I In=100A 3p F F 1SDA067058R1 XT2N 160 Ekip LS/I In=160A 3p F F 1SDA067767R1 XT2S 160 MA 52 Im=314...728 3p F F 1SDA067861R1 XT2H 160 Ekip LS/I In=160A 3p F F 1SDA067768R1 XT2S 160 MA 80 Im=480...1120 3p F F 1SDA067074R1 XT2N 160 Ekip LSIG In=63A 3p F F 1SDA067769R1 XT2S 160 MA 100 Im=600...1400 3p F F 1SDA067874R1 XT2H 160 Ekip LSIG In=63A 3p F F 1SDA067075R1 XT2N 160 Ekip LSIG In=100A 3p F F 1SDA067076R1 XT2N 160 Ekip LSIG In=160A 3p F F 1SDA067875R1 XT2H 160 Ekip LSIG In=100A 3p F F 1SDA067876R1 XT2H 160 Ekip LSIG In=160A 3p F F XT3 250 Thermal magnetic - Fixed (F) - 3 poles - Front terminals 36 ka 50 ka 1SDA068053R1 XT3N 250 TMD 63-630 3p F F 1SDA068215R1 XT3S 250 TMD 63-630 3p F F 1SDA068054R1 XT3N 250 TMD 80-800 3p F F 1SDA068216R1 XT3S 250 TMD 80-800 3p F F 1SDA068055R1 XT3N 250 TMD 100-1000 3p F F 1SDA068217R1 XT3S 250 TMD 100-1000 3p F F 1SDA068056R1 XT3N 250 TMD 125-1250 3p F F 1SDA068218R1 XT3S 250 TMD 125-1250 3p F F 1SDA068057R1 XT3N 250 TMD 160-1600 3p F F 1SDA068219R1 XT3S 250 TMD 160-1600 3p F F 1SDA068058R1 XT3N 250 TMD 200-2000 3p F F 1SDA068220R1 XT3S 250 TMD 200-2000 3p F F 1SDA068059R1 XT3N 250 TMD 250-2500 3p F F 1SDA068221R1 XT3S 250 TMD 250-2500 3p F F XT4 160/250 Thermal magnetic and electronic - Fixed (F) - 3 poles - Front terminals 36 ka 70 ka 1SDA068090R1 XT4N 250 TMA 200-2500 3p F F 1SDA068092R1 XT4N 250 TMA 250-2500 3p F F 1SDA068343R1 XT4H 250 TMA 200-2000 3p F F 1SDA068345R1 XT4H 250 TMA 250-2500 3p F F 1SDA068125R1 XT4N 160 Ekip LS/I In=160A 3p F F 1SDA068126R1 XT4N 250 Ekip LS/I In=250A 3p F F 1SDA068514R1 XT4H 160 Ekip LS/I In=160A 3p F F 1SDA068515R1 XT4H 250 Ekip LS/I In=250A 3p F F 1SDA068140R1 XT4N 160 Ekip LSIG In=160A 3p F F 1SDA068141R1 XT4N 250 Ekip LSIG In=250A 3p F F 1SDA068529R1 XT4H 160 Ekip LSIG In=160A 3p F F 1SDA068530R1 XT4H 250 Ekip LSIG In=250A 3p F F 1SDA069601R1 XT4N 160 Ekip E-LSIG In=40A 3p F F 1SDA069602R1 XT4N 160 Ekip E-LSIG In=63A 3p F F 1SDA069603R1 XT4N 160 Ekip E-LSIG In=100A 3p F F 1SDA069604R1 XT4N 160 Ekip E-LSIG In=160A 3p F F 1SDA069605R1 XT4N 250 Ekip E-LSIG In=250A 3p F F 1SDA069621R1 XT4H 160 Ekip E-LSIG In=40A 3p F F 1SDA069622R1 XT4H 160 Ekip E-LSIG In=63A 3p F F 1SDA069623R1 XT4H 160 Ekip E-LSIG In=100A 3p F F 1SDA069624R1 XT4H 160 Ekip E-LSIG In=160A 3p F F 1SDA069625R1 XT4H 250 Ekip E-LSIG In=250A 3p F F XT1 - XT3 Switch disconnector - Fixed (F) - 3 poles - Front terminals 1SDA068208R1 XT1D 160 3p F F 1SDA068210R1 XT3D 250 3p F F Tmax XT 7

Electronic trip unit Names Names Application Protection functions Ekip E Distribution Energy metering LS/I, LSIG LSIG 10 7 1 2 3 4 Ekip LED Meter 9 8 5 6 Ekip LED Meter can be easily installed on the front of Ekip LSIG and Ekip E-LSIG electronic trip units by means of the test connector on the front of the release. Ekip LED Meter provides an accurate indication of the value of the current flowing through the trip unit by means of an LED scale, which is able to discriminate between operation, pre-alarm and alarm. Characteristics 1. LEDs Protection L, S, I, G 2. Power on LED 3. Lead seal arrangement 4. USB test connector 5. Manual / electronic configuration selector 6. Local / remote configuration selector 7. Selection of S time-current curve 8. Selection of protection functions thresholds 9. Configuration of LSIG protection functions 10. ON/ OFF selector for Neutral Ekip Com Ekip Display Ekip Display can easily be installed on the front of the Ekip LSIG and Ekip E-LSIG electronic trip units by the means of the test connector on the front of the trip unit. Ekip Display has four buttons for browsing though the menus. Ekip Display Shows the current values. Shows the settings of the protection functions. Shows the protection that caused the release to trip and the fault current. Allows the trip thresholds of the trip unit to be programmed and the communication parameters to be set on bus system. Test and programming units Circuit-breaker 3 poles Ekip Com is able to connect Ekip LSIG and Ekip E-LSIG electronic trip unit to a Modbus communication line so that ON/OFF/TRIP state of the circuit-breaker can be detected and MOE-E motor operator can be controlled. Ekip Com module is installed in a dedicated slot in the righthand pole of the circuit-breaker without any need for screws or tools. Ekip Com module allows the trip unit to be connected to a Modbus network, offering the possibility of programming the protections and acquiring the measurements and alarms when it is connected to a control and/or supervision system. When it is connected to the HMI030 unit, it is possible to have data locally on the front of the switchboard. Ekip T&P test and programming purpose offers supervision, configuration and testing of advanced electronic trip units.. Ekip TT can be used to verify the correct functioning of the electronic trip unit s actuation mechanism and to give supply to the trip unit after the breaker trip. Ekip T&P software Ekip Connect is a software for installation and diagnosis for ABB products with Modbus RTU communication. In combination with Ekip T&P unit it is possible to perform any test on the trip unit protection functions. 8 Tmax XT

Electrical accessories Auxiliary Contacts Circuit-breaker 3 pole Service releases To be mounted without the need of any screw Q: Open/closed auxiliary contact SY: Trip position auxiliary contacts S51: Trip position due to trip unit intervention Service releases 3 pole circuit-breaker Shunt opening release (SOR) opens the circuit-breaker by means of a non-permanent electrical control. Undervoltage release (UVR). Opens the circuit-breaker when the release is subjected to either a power failure or voltage drop. Motor operators Device that operates the circuit-breaker in the remote mode, by means of electric controls with thanks to the new design, power consumption is now reduced. Accessories for electronic Trip Units 1SDA068659R1 EKIP DISPLAY x LSI-LSIG-M/LRIU XT2-XT4 1SDA068660R1 EKIP LED METER x LSI-LSIG-M/LRIU XT2-XT4 1SDA068661R1 EKIP COM x LSI-LSIG-M/LRIU XT2-XT4 F/P 1SDA066988R1 Ekip TT XT2-XT4 1SDA066989R1 Ekip T&P XT2-XT4 1SDA069142R1 EXT NEUTRAL CT 63A XT2 1SDA069143R1 EXT NEUTRAL CT100A XT2 1SDA069144R1 EXT NEUTRAL CT160A XT2 1SDA066978R1 EXT NEUTRAL CT160A XT4 1SDA066979R1 EXT NEUTRAL CT250A XT4 Electrical accessories SOR Shunt trip releases 1SDA066314R1 SOR XT1..XT4 24-30 Vac/dc 1SDA066317R1 SOR XT1..XT4 220...240 Vac-220...250 Vdc UVR Undervoltage releases 1SDA066389R1 UVR XT1..XT4 24-30 Vac/dc 1SDA066392R1 UVR XT1..XT4 220-240Vac-220-250Vdc AUX Auxiliary contacts 1SDA066422R1 AUX 250 V XT1..XT4 1SDA066424R1 AUX-SA 250 V XT2-XT4 Motor operators 1SDA066457R1 MOD XT1-XT3 24V dc 1SDA066460R1 MOD XT1-XT3 220...250 V ac/dc Stored energy motor operator MOE, for XT2 and XT4 Direct action motor operator, MOD, for XT1 and XT3 1SDA066463R1 1SDA066466R1 MOE XT2-XT4 24 V dc MOE XT2-XT4 220...250 V ac/dc Tmax XT 9

Mechanical accessories Rotary handles Operating device that allows the circuit-breaker to be operated by means of a rotary handle direct (RHD) and panel mounted (RHE) rotary handle are available. Connection terminals Tmax XT range of connection terminals is now more complete and consistent through the whole range. Rear terminals, extended front terminals, extended spread terminals and copper cable terminals are available for all the frame sizes. Separating partitions and insulating terminal covers can be selected for Tmax XT circuit-breakers. Direct rotary handle Panel mounted rotary handle Mechanical interlock Designed for installation on the rear of two circuit-breakers, mechanical interlock prevents two circuit-breakers from being closed simultaneously. Tmax XT circuit-breakers and switch-disconnectors can be interlocked two-by-two (IO-OI-OO) by means of a frame and special plates, no matter if the breaker is in 3pole or 4pole version. Rear interlock is available also on 160A frame circuit-breakers, so that use of ATS022 (Automatic Transfer Switch Unit) is no more limited to big frame size circuit-breakers. Keylocks and padlocks Padlocks or key locks that prevent the circuit-breaker from being closed and/or opened can be fitted: - Directly on the front of the circuit-breaker. - On the rotary handle operating mechanism. - On the front for lever operating mechanism. - On the motor. ATS022 The ATS022 (Automatic Transfer Switch) is the networkgenerator transfer unit used in installations. 10 Tmax XT

Terminal connections Mechanical accessories Copper cable terminals Rotary handles 1SDA066905R1 KIT FC Cu XT1 3pcs 1SDA066475R1 RHD XT1-XT3 F/P STANDARD DIRECT 1SDA066909R1 KIT FC Cu XT2 3pcs 1SDA069053R1 RHD XT2-XT4 F/P STANDARD DIRECT 1SDA066913R1 KIT FC Cu XT3 3pcs 1SDA066479R1 RHE XT1-XT3 F/P STANDARD RETURNED 1SDA066917R1 KIT FC Cu XT4 3pcs 1SDA069055R1 RHE XT2-XT4 F/P STANDARD RETURNED Extended Front terminals Key locks on circuit breaker 1SDA066865R1 KIT EF XT1 3pcs 1SDA066593R1 KLC XT1 KEY LOCK RONIS SEV.OP. X C.BREA. 1SDA066869R1 KIT EF XT2 3pcs 1SDA066594R1 KLC XT1 KEY LOCK RONIS EQ.FEL.A OP.xC.BR 1SDA066873R1 KIT EF XT3 3pcs 1SDA066599R1 KLC XT2-XT4 KEY LOCK RONIS SE.OP.xC.BRE. 1SDA066877R1 KIT EF XT4 3pcs 1SDA066600R1 KLC XT2-XT4 KEY LOCK RONIS EQ.FE.A OP.xB Extended Spread terminals 1SDA066605R1 KLC XT3 KEY LOCK RONIS SEV.OP. X C.BREA. 1SDA066889R1 KIT ES XT1 3pcs 1SDA066606R1 KLC XT3 KEY LOCK RONIS EQ.FEL.A OP.xC.BR 1SDA066893R1 KIT ES XT2 3pcs Key locks on rotary handle 1SDA066897R1 KIT ES XT3 3pcs 1SDA066617R1 RHL XT1..XT4 KEY LOCK RONIS DIFF. KEY RH 1SDA066901R1 KIT ES XT4 3pcs 1SDA066622R1 RHL XT1..XT4 KEY LOCK RONIS DIFF. KEY OP/CL Rear terminals Padlock devices 1SDA066937R1 KIT R XT1 3pcs 1SDA066588R1 PLL XT1-XT3 PADLOCKS DEVICE REMOV 1SDA066941R1 KIT R XT2 3pcs 1SDA066591R1 PLL XT1-XT3 PADLOCKS DEVICE OP/CL 1SDA066945R1 KIT R XT3 3pcs 1SDA066592R1 PLL XT2-XT4 PADLOCKS DEVICE OP/CL 1SDA066949R1 KIT R XT4 3pcs High terminal covers Automatic Transfer Switch 1SDA066664R1 HTC XT1 3p TERMINAL COVERS HIGH 2pcs 1SDA065524R1 ATS022 AUTO TRANSFER SWITCH RELAY 1SDA066666R1 HTC XT2 3p TERMINAL COVERS HIGH 2pcs 1SDAA99203A1 Loom kit 1SDA066668R1 HTC XT3 3p TERMINAL COVERS HIGH 2pcs 1SDAA99303A1 BTSXT1N160T33H(160) In=160, Icu=36kA 1SDA066670R1 HTC XT4 3p TERMINAL COVERS HIGH 2pcs 1SDAA99333A1 BTSXT1N160T34H(125) In=160, Icu=36kA Low terminal covers 1SDAA99309A1 BTSXT1H160T33H(160) In=160, Icu=70kA 1SDA066655R1 LTC XT1 3p TERMINAL COVERS LOW 2pcs 1SDAA99339A1 BTSXT1H160T34H(160) In=160, Icu=70kA 1SDA066657R1 LTC XT2 3p TERMINAL COVERS LOW 2pcs 1SDAA99503A1 BTSXT3N250T33H(250) In=250, Icu=36kA 1SDA066660R1 LTC XT3 3p TERMINAL COVERS LOW 2pcs 1SDAA99532A1 BTSXT3N250T34H(200) In=200, Icu=36kA 1SDA066662R1 LTC XT4 3p TERMINAL COVERS LOW 2pcs 1SDAA99309A1 BTSXT1H160T33H(160) In=160, Icu=70kA Low phase barriers 1SDAA99339A1 BTSXT1H160T34H(160) In=160, Icu=70kA 1SDA066676R1 PB 100mm 4pcs XT1-XT3 3p 1SDAA99603A1 BTSXT4H250T33H(250) In=250, Icu=70kA 1SDA066675R1 PB 100mm 4pcs XT2-XT4 3p 1SDAA99633A1 BTSXT4H250T34H(250) In=250, Icu=70kA High phase barriers 1SDA066678R1 PB 200mm 4pcs XT1-XT3 3p 1SDA066677R1 PB 200mm 4pcs XT2-XT4 3p Tmax XT 11

Tmax XT Dimensional drawings XT1 XT3 12 Tmax XT

XT2 XT4 Tmax XT 13

Tmax XT Really extraordinary attention to environment. The ABB Quality System conforms to the following standards: ISO 9001 international standard EN ISO 9001 (equivalent) European standard UNI EN ISO 9001 (equilvalent) Italian standards IRIS international railway industry standard The ABB Quality System attained its first certification with the RINA certification body in 1990. The commitment to environmental protection becomes concrete through: Selection of materials, processes and packaging which optimise the true environmental imact of the product. Use of recyclable materials. Respect of the RoHS directive ISO 14001, 18001 and SA8000 recongnitions together with ISO 9001 made it possible to obtain RINA BEST FOR CERTIFICATIONS. 14 Tmax XT

Tmax XT extraordinary commitment to obtaining all the most important certifications. Thanks to its quality and reliability Tmax XT has the approvals for the most important registers. Tmax XT 15

Contact us ABB Australia Pty Limited 601 Blackburn Road Notting Hill VIC 3168. Phone:1300 660 299 Fax: 1300 853 138 Email: atlvsales@au.abb.com www.abbaustralia.com.au/lowvoltage The data and illustrations are not binding. We reserve the right to modify the contents of this document on the basis of technical development of the products, without prior notice.