New range of reclosing systems

Similar documents
Solutions for earth leakage protection and circuit breakers with automatic reclosing system

Protection and control. Self-reclosing overload and earth leakage protection

Product selection table

CONTENTS. Earth leakage and overload/short circuit protection systems with self-reclosing Associated breaking element

Protection and control P. 1 /2. Smart earth leakage protection

P.1 CONTENTS. Industrial Earth Leakage Protection. Page

Electric Switchboards

Smart earth leakage protection

Solutions for Electrical energy efficiency

Automatic capacitor banks

AUTOMATIC CAPACITOR BANK WITH CONTACTOR OPERATIONS

CIRCUTOR s Energy Management System

LCL FILTERS INSTRUCTIONS MANUAL (M A) (c) CIRCUTOR S.A.

Smart equipment and Systems for electric vehicle charging

Protection and control P. 1 /2. Smart earth leakage protection

Mobility & emobility

Operation of a CDP in SPLIT-PHASE installations

Air Circuit Breakers

RVS-DN Digital Reduced Voltage Motor Starter

RVS-DX Digital Reduced Voltage Motor Starter

Innovating to shape the present and move towards the future

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

01 Spectra Plus - Introduction

Solid Dielectric, Single Phase Recloser

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Air Circuit Breakers

Solutions for Self-consumption

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

Observe all necessary safety precautions when controlling the soft starter remotely. Alert personnel that machinery may start without warning.

KD LV Motor Protection Relay

Application Engineering

HGM7100N SERIES (HGM7110N/7120N) GENSET CONTROLLER USER MANUAL

BT300 HVAC Drives Conventional Bypass (C-Bypass) Options

Liebert. FP 50Z kva

RESIDUAL CURRENT CIRCUIT BREAKER

USERS MANUAL MCD REMOTE OPERATOR

A21M. Introduction: Functional Overview: Key Protection & Control Functions:

Moulded case circuit breakers

Self-consumption solutions

SPEEDRIVE INSTRUCTIONS MANUAL

Bulletin 825 SMM Smart Motor Manager

DEEP SEA ELECTRONICS PLC

Designed for ease of integration with automation systems

Application Note: Protection of Medium-Power Motors With SIPROTEC Compact 7SK80

Application Engineering

OSS - TN, TBN Type. Information to Order. Features. External View ATS(60~600A) OSS P- A B C D. Rated Current. D Operating Voltage

HGM1750 Genset Security Module USER MANUAL Smartgen Technology

(p. 47) (p. 155) (p. 155)

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

The University of New South Wales. School of Electrical Engineering and Telecommunications. Industrial and Commercial Power Systems Topic 6

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

Smart Energy Control With the use of new technologies

Thermal Overcurrent Circuit Breaker 3120-F...

Data sheet. CI-tronic Soft start motor controller Type MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 50 I-O 520B1443

PD-Series Ground Fault Circuit Protection

MINIATURE CIRCUIT BREAKER

COMPLETE SOLUTIONS FOR POWER PROTECTION

NEW The new PROmax power supplies offer a wide range of robust solutions for demanding application requirements.

HGM1780 AUTOMATIC GENERATOR MODULE CONTENT 1. SUMMARY PERFORMANCE AND CHARACTERISTICS SPECIFICATION OPERATION...

New DX 3 High rating & breaking capacity

Pulsar EXtreme 2200C / 3200C

Thermal-magnetic Miniature Circuit Breaker 4230-T...

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

QUOTATION BLADE 7 LX. Product code GEAL6S2BAA

U n i n t e r r u p t i b l e P o w e r S y s t e m

Thermal Overcurrent Circuit Breaker 3120-F...

SecureUPS On-Line 120V AC Output, 1300VA

Installation and Maintenance Instructions. World Leader in Modular Torque Limiters. PTM-4 Load Monitor

CI-Tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

DEEP SEA ELECTRONICS PLC

HGM1780. Automatic Genset Controller USER MANUAL. Smartgen Technology

Thermal Overcurrent Circuit Breaker 3120-F...

DMX 3 -I 2500 switch disconnectors

User Manual. Solar Charge Controller 3KW

ampcontrol s Hard rock relay range

INSTALLATION INSTRUCTIONS FOR SYMCOM'S MODEL 777-HVR-SP ELECTRONIC OVERLOAD RELAY

Essential Loads also use stand by generator systems mostly in process industries as they relate to high restarting times or high down times.

Breaker failure relay REB 010

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

MCD 200 Series Soft Starters

DEVICE STATE/BYPASSED FAILURE OVERLOAD

1.7. Portable insulation fault location system EDS3060/EDS3360 in combination with EDS460/461 systems

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

Solid Dielectric, Triple Option Reclosers Catalog O-vlt14

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

RAPTOR DEFAULT TEST TEMPLATES

User Manual Solar Charge Controller 3KW

HIGH POWER SOLENOID DRIVER 1

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Residual current devices

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

TX³ RCCBs 2P up to 100 A

CirPark. EFFICIENT PARKING Product Catalogue 2017 SOLUTIONS FOR. Solutions for Efficient Parking. circontrol.com

020: 2013 CEB SPECIFICATION MINIATURE CIRCUIT BREAKER (MCB)

Thermal Overcurrent Circuit Breaker 3120-F...

PowerValue 11/31 T kva

Transcription:

Protection and Control RECmax New range of reclosing systems Earth leakage and circuit breaker protection with automatic earth leakage reclosing system. Manage its installation remotely Energy efficiency technology

How to enhance electrical quality and continuity for your infrastructures or services by ensuring electrical protection Today, our industrial production processes and the myriad of services for individuals normally entail a constant demand for electrical energy. Electrical service continuity ensures high energy management efficiency (ISO 50001) in our companies and quality of life for individuals in their homes or places of entertainment. When dealing with electrical protection, one of the most frequently used solutions for protection devices is to cut off the electric supply from affected areas when an insulation fault is detected. Therefore, we are faced with a critical electric supply continuity point, given that services and production processes are interrupted to protect people against electrocution or property against fire hazards or other damage. Clearly, this is the correct decision. Safety comes first, even though we cannot leave our installations without electrical service indefinitely, especially infrastructures, production processes or services that are difficult to maintain. These types of applications make it necessary to use intelligent automatic reclosing earth leakage and circuit breaking protection devices. This implies devices that guarantee protection activated only when the problem is real, with capacity to re-establish the electric supply under the reclosing conditions required by the application. CIRCUTOR offers equipment that self-manages anomalous and random situations in electrical installations, minimizing the effects of power cuts and making energy saving easier.

CIRCUTOR presents, within a wide range of solutions for the automatic reclosing of circuit breakers and earth leakage protection, an exclusive range for installations of up to : RECmax NEW RECmax RANGE Protection with s and earth leakage s and earth leakage Triggered reclosing s and earth leakage * s and earth leakage * Leak display Yes Yes (RGU-10C MT) Communications RS-485 Yes (RGU-10C MT) RECmax P RECmax LPd Earth leakage transf. 25 / 35 RECmax MP Earth leakage transf. 25 / 35 + RGU-10 C MT *The programming of the equipment allows circuit breaker reclosing to be disabled.

Comparison table. RECmax range The RECmax range of products for the earth leakage and circuit breaker protection of the installation is capable of meeting the needs of any installation up to. Model design with special features depending on specific needs, for example: preventive maintenance, control and telemanagement of electrical installations. Protection with Earth leakage and/or circuit breaker Reclosing with Earth leakage and/or circuit breaker Classification of models based on need, installation and features of the model. RECmax MP + RGU-10 C MT + RECmax LPd + RECmax P Customer need Continuity of service Status outputs Control, telemanagement, telecontrol LCD Display RS-485 communication Installation (RGU-10C MT) Single-phase Three-phase (4 wires) Three-phase Used with external earth leakage transformers Nominal current Attached to DIN rail Size in DIN modules 7.5 / 9.5 (with RGU-10C MT) 4.5 / 6.5 4.5 / 6.5 Protection features Type A earth leakage protection(ultra-immunized) Used for instantaneous protection Use as selective protection Configurable system in terms of time and current Pre-alarm/status output Programmable Standard IEC 60947-2 Appendix M, IEC 62020 IEC 60898 Reclosing system features Number of reclosing procedures, N 3 Time between reclosing procedures, T Reclosing meter RESET time Programmable N T 3 minutes 30 minutes

Application in industries and offices The dual function of earth leakage protection devices as automatic reclosing elements enables them to be used in earth leakage protection and circuit breaker applications. Possible applications of these units in low or zero supervision installations or infrastructures are, among others: yytelecommunications stations, signalling and control boxes yywater and gas distributors, pumping blocks yyphotovoltaic installations, panels yycomputer systems, UPS yyfood preservation Supermarkets, frozen food companies, refrigerating chambers Hotels, restaurants, catering (HORECA) Climate controls, heat pumps, air-conditioning yy24-hour public services, ATMs, banks, etc. yyexterior building lighting, stores and illuminated indicators yymunicipal infrastructures, traffic lights, public lighting yyautomation, home automation, alarms, garage doors, irrigation systems. CBS-4 C Ethernet RS-485 EDS RGU-10 C Air-conditioning Line Lighting Line Power Line 1 Power Line 2 RECmax P RECmax LPd 4 Poles RECmax LPd 2 Poles RECmax P RGU-10C MT RECmax P

RECmax LPd Earth leakage circuit breaker with self-reclosing system and display (LCD) Compact dimensions 2 Poles 4 Poles Description Self-resetting cut off device with circuit breaker and ultra-immunizedearth leakage protection. Programmable unit with display, which measures leakage currents (earth leakage protection), and orders the disconnection or reclosing of the circuit breaker (circuit breaker protection) through a motor that controls it mechanically. The leakage current measurement, I Δ, needs an external earth leakage / WGStransformer, which is supplied separately. The assembly is regularly used in electrical, single-phase and three-phase installations that require high continuity of the electric supply. It has inputs/outputs which provide information and control on the state of the electrical installation where it is working. x7.5 6 to x9.5 6 to Simple, intuitive programming N T t A External signals x2 outputs Remotely manageable x1 input Remote control LCD DISPLAY LED display and backlit (LCD) display: yyearth leakage protection/reclosing parameters. yyprotection trip current. yynumber of reclosures yyprotection status messages, etc. Applications The RECmax LPd connected to the / WGS toroidal transformers ensure earth leakage and circuit breaker protection with self-reclosing after an earth leakage, overload or short-circuit trip. It is a good solution for those infrastructures that are hard to control and monitor because of their location in the following control boards: yytelephony systems yydtt systems yycomputer systems, UPS yyother difficult maintenance services Parameter display Trigger event display Display due to earth leakage protection. External signal trigger, remote control. No. reclosures made. TEST trigger Instantaneous leakage current value. Nº reclosings due to earth leakage trip. Trip current value.

RECmax LPd Earth leakage circuit breaker with self-reclosing system and display (LCD) Installation elements Technical features RECmax LPd Protection Protection Earth leakage Class A (IEC 60755) A ultra-immunized Measurement True root mean square (TRMS) Adjustable sensitivity 0.03-0.1-0.3-0.5-1 A (*) Trip delay Trip curves: INS, SEL Time defined: 0.1-0.2-0.3-0.4-0.5-0.6-0.8 1 sec. Test and Reset Using buttons T and R Sensor element to connect / WGS earth leakage transformer Integrated element Motorized circuit breaker Current, 6-10-16-20-25-32-40-50- Number of poles 2/4 Dimensions 45 86 90 110 35 50 115 79 83 33 90 110 45 Rated voltage U n 240 / 415 V AC Trip curves C Cut off power (EN 60898) 6 ka Reclosing system No. of reclosures Programmable Time between reclosures In accordance with sequence configured RESET time In accordance with sequence configured External signalling LED Presence of voltage, leakage trip, timing between reclosures LCD Display Instantaneous value of leakage, trip leakage value, reclosing energy meter, programming values, protection statuses Remote Potential free auxiliary contact output, of the locking status (reclosing not enabled) and circuit breaker position status External inputs Remote circuit breaker ON/OFF Opening time < 10 ms Pulse time for opening > 200 ms Closure time < 1,000 ms Pulse time for closing > 200 ms Electrical Auxiliary power supply 230 V AC features Remote locking output contact Potential free, 230 V, maximum current 250 ma Remote output contact of circuit breaker position Remote control inputs Potential free, 230 V, maximum current 500 ma Voltage-free, activated by button or external switch Mechanical features Operating temperature -10...+50 ºC Fixing DIN rail 46277 (EN 50022) Dimensions (modules) 4.5 (2 poles) - 6.5 (4 poles) Mechanical working life > 10,000 operations Weight (g) 452 (2-pole) 703 (4-pole) Protection degree IP 20 terminals IP 41 embedded Plug-in connection terminals Vertical orientation Standards IEC 60947-2, IEC 60755 (*) if adjusted to an earth leakage trigger of 30 ma, the default delay is set to INStantaneous.

RECmax MP Motorized automatic switch (up to ) Compact dimensions 2 Poles x4.5 6 to x6.5 4 Poles 6 to External signals Remotely manageable x2 outputs x2 inputs Installation elements Remote control Description The RECmax MP series are motorized circuit breaker switches. They protect against short-circuits and overloads, but are also used as circuit breakers. After a disconnection caused by a circuit breaker, the switch can be reconnected through an external order. It has two inputs which, through voltage-free external signals, order the opening (input O) and subsequent closing (reclosing system) of the circuit breaker (input I). It also has three outputs for signalling the status and the cause of the opening and closing of the circuit breaker (trigger, manual/test). Applications The RECmax MP series are motorized circuit breakers that can be controlled remotely, apt for any application in which remote connection/disconnection control is required. They are also used as circuit breakers linked to CIRCUTOR self-reclosing relays. They are a vital accessory in the automatic self-reclosing overload and earth leakage protection process. Technical features Protection Integrated circuit breaker Motorized circuit breaker Current, 6-10-16-20-25-32-40-50- Number of poles 2 / 4 RECmax MP RGU-10C MT Rated voltage U n 240 / 415 V AC Cut off power (EN 60898) 6 ka Trip curve C External signalling LEDs Presence of voltage OFF/ON Remote Locking status (reclosing not enabled) position status Opening time < 10 ms external input OFF Pulse time for opening > 10 ms Closure time < 1,000 ms external input ON Pulse time for closing > 10 ms With reclosing element and earth leakage RGU-10C MT + Simple, intuitive programming N T t A Communications RS 485 LCD DISPLAY Electrical features Auxiliary power supply 230 ±30% V AC Working frequency range 50 60 Hz Remote locking output Auxiliary contact potential-free, 230 V, maximum current 250 ma position double remote output Remote control external inputs OFF/ON Auxiliary contact potential-free: 230 V, maximum current 500 ma 230 V, maximum current 100 ma Voltage-free pulse-activated (t > 10 ms) Mechanical features Operating temperature -10 +50 ºC Fixing DIN rail 46277 (EN 50022) Mechanical working life > 10,000 operations Dimensions (modules) 6.5 modules - 4-pole 4.5 modules - 2-pole Weight (g) 452-2-pole 703-4-pole Protection degree Terminals IP20, embedded IP41 Plug-in connection terminals Vertical orientation Standards IEC 60947-2, IEC 60898

RECmax P Motorized automatic reset circuit breaker (up to ) Compact dimensions 2 Poles x4.5 6 to x6.5 4 Poles 6 to External signals Remotely manageable x2 outputs x2 inputs Depending on the fixed automatic reclosing sequence Sequence of 3 timed reclosings every N T 3 minutes with a 30-minute restart time after the last reclosing. Installation elements RECmax P Remote control Description The RECmax P series are 2- and 4-pole circuit breakers connected to a compact motor and internal control unit that enables automatic reclosing. After a trip, the switch recloses, following a sequence of 3 reclosings with 3 minutes between rearms. If the unit is not able to reconnect after 3 attempts, it remains triggered until a manual or remote reset is made. They can also be connected remotely to an external control. It has two inputs which, through voltage-free external signals, order the opening (input O) and subsequent closing (reclosing system) of the circuit breaker (input I). It also three two singlecontact outputs for signalling the status and the cause of the opening of the circuit breaker (trigger, manual/test). Applications The RECmax P series are motorized circuit breakers that can be rearm automatically or controlled remotely, suitable for any application in which remote connection/ disconnection control is required. They are an essential accessory for protection and automatic circuit breaker and earth leakage reclosing system, and for external connection/disconnection control. Technical features Protection Reclosing activated by: Integrated circuit breaker Motorized circuit breaker Current, 6-10-16-20-25-32-40-50- Number of poles 2 / 4 Rated voltage U n 240 / 415 V AC Cut off power (EN 60898) 6 ka Trip curve C No. of reclosures 3 Time between reclosures 3 minutes Reset time 30 minutes External signalling LEDs voltage OFF/ONTiming between reclosings Remote Locking status (reclosing not enabled) position status. Opening time < 10 ms external input OFF Pulse time for opening > 10 ms Closure time < 1,000 ms external input ON Pulse time for closing > 10 ms Electrical features Auxiliary power supply 230 ±30% V AC Working frequency range 50 60 Hz Locking remote output position double remote output Remote control external inputs OFF/ON Plug-in connection terminals Auxiliary contact potential-free, 230 V, maximum current 250 ma Auxiliary contact potential-free: 230 V, maximum current 500 ma 230 V, maximum current 100 ma Voltage-free pulse-activated (t > 10 ms) Vertical orientation Mechanical features Operating temperature -10 +50 ºC Fixing DIN rail 46277 (EN 50022) Mechanical working life > 10,000 operations Dimensions (modules) 6.5-4-pole, 4.5-2-pole Weight (g) 452-2-pole, 703 4-pole Protection degree Terminals IP20, embedded IP41 Plug-in connection terminals Vertical orientation Standards IEC 60947-2, IEC 60898

Symbols x4 40 A Dimensions (DIN modules) Nominal currents N T Configurable automatic reclosing parameters t A Configurable earth leakage protection settings I Δn 30 ma 300 ma Sensitivity LCD DISPLAY Display Key TEST TEST button, earth leakage protection Opt. output Aux. contact status outputs. Opt. input Remote control input 6 to Range of nominal currents Opt. RS 485 RS-485 communication output: RECmax LPd Versatile Available in 2- and 4-pole for all types of installations. Control Remote-control input: Easy Quick connection from the earth leakage transformers via removable terminal. Safe Mechanical reconnection locking. Visual Display of statuses, parameters and trigger events with the LCD displayand LEDs. Control Through the outputswe can have protection status and reclosing alarms

Management and monitoring software With PowerStudio Scada you can: yyguarantee the accurate energy supervision of your installation yyachieve the preventive maintenance of all lines and installations The RGU-10 C series uses the standardized Modbus/RTU (RS-485) or Modbus/ TCP (Ethernet) protocols, which can be queried from any other market application. http://powerstudio.circutor.com

REC Max New range of reclosing systems + information: proteccion@circutor.es www.circutor.com Designed by: Image and Communications Department - CIRCUTOR, SA CIRCUTOR, SA - Vial Sant Jordi, s/n 08232 Viladecavalls (Barcelona) Spain Tel. (+34) 93 745 29 00 - Fax: (+34) 93 745 29 14 central@circutor.es Code: C2P263-01 CIRCUTOR, SA reserves the right to make changes to the content of this catalogue.