K0 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads
Overview K0 Circuit Breaker Technical Specification MCB RCCB K0 Circuit Breaker K0N K0H ID K Number of poles -- -- Electrical characteristics General contents Rated current (A) In - - - 0 - Rated Insulation Voltage (V) Ui 0 0 0 Maximum operational voltage (V) Ue AC 0/0 Hz 0 00 0 00 0 Fast closing b b b Suitability for isolation b b b AC breaking capacity IEC 0898 (EN 0898) Icn (A) 0/00 V 000 0000 Equal to K0 Ics (%of Icn) 00% 00% 7% 7% - - Trip units (non adjustable) B (Im = to In) b b - Curve type C (Im = to 0 In) b b - D (Im = 0 to In) - - - Integrated - - b Overview K0 Circuit Breaker Technical Specification... K0 Biconnect Circuit Breakers... K0N Biconnect Circuit Breakers... K0H Biconnect Circuit Breakers...7 Sensitivity type (ma) a AC - - b Electrical auxiliaries Auxiliary and alarm switches (OF-SD) - - - Shunt trip (MX); undervoltage release (MN) - - - Emergency stop opening switch (MNx) - - - Voltage threshold release (MSU) - - - Flexible (y0a) (>0A) Cable maxi capacity (mm ) Rigid (y0a) (>0A) Installation Dimensions (mm) W 8 per pole 7 D x H 7 x 8 8 x 8...8
K0 Biconnect circuit breakers K0 Biconnect circuit breakers Fast closing independent of the speed of actuation of the toggle. Technical Data Main characteristics K0N K0H Insulation voltage (Ui) Phase-to-phase 0 V AC Phase-to-neutral 0 V AC Voltage rating (Ue) Phase-to-phase 00 V AC Reinforced cable pull-out strength: serrated terminals Clip on DIN rail mm. B curve to In Magnetic tripping C curve to 0 In According to EN 0898- Limitation class Rated breaking capacity (Icn) 000 A 0000 A Padlocking device Padlocking possible for work to be carried out on live parts Service breaking capacity (Ics) 00 % of Icn 7 % of Icn Rated breaking and making capacity on a single pole (Icn) Additional characteristics Icn = Icn Indifferent position of installation. Degree of protection (IEC 09) Endurance (O-C) Device in modular enclosure Electrical IP0 Insulation class II >0 A 0,000 cycles < A 0,000 cycles Downstream by Biconnect comb busbar Upstream/downstream by tunnel terminals IP0 Operating temperature Storage temperature Tropicalization (IEC 008-) Mechanical 0,000 cycles - C to + C - C to +8 C Treatment (relative humidity 9% at C) Weight (g) Circuit-breaker Common characteristics Type P P P P Type K0 Biconnect K0 Biconnect 0 0 0 80 mm PZ. mm Rating to 0 A to A Tightening torque N.m. N.m Copper cables Rigid 0. to mm 0. to mm Dimensions (mm) P 7 7 P 9. P 0 P 8 Flexible or with ferrule 0. to mm 0. to mm 8. 8 by comb busbar or cables (conforms to EN 007).
7 K0N Biconnect circuit breakers K0H Biconnect circuit breakers IEC/EN 0898- K0N Biconnect circuit breakers are circuit breakers which combine the following functions: C ircuit protection against short-circuit currents against overload currents Disconnection, opening and closing IEC/EN 0898- K0H Biconnect circuit breakers are circuit breakers which combine the following functions: C ircuit protection against short-circuit currents against overload currents Disconnection, opening and closing K0N Biconnect circuit breaker 0/0 Hz Breaking capacity in short circuit (Icn) as per IEC/EN 0898- K0H Biconnect circuit breaker 0/0 Hz Breaking capacity in short circuit (Icn) as per IEC/EN 0898- Ph/Ph 00 V Ph/Ph 00 V Ph/N 0 V Ph/N 0 V Product Reference K0N Biconnect circuit breaker Rating (In) to A 000 A Service breaking capacity (Ics) 00 % of Icn Type P P P P Product Reference K0H Biconnect circuit breaker Rating (In) to A 0000 A Service breaking capacity (Ics) 7 % of Icn Type P P P P 7 7 8 8 Auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Without auxiliaries Rating (In) Curve B C B C B C B C Rating (In) Curve B C B C B C B C A A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 0 A A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 0 A A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 0 A A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 0 A A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A9K00 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 Width in 9-mm modules 8 Accessories Padlocking device cat. no. 970 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 0 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A A9K A9K A9K A9K A9K A9K A9K A9K 0 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A A9K A9K A9K A9K A9K A9K A9K A9K 0 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 0 A A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A9K0 A A9K A9K A9K A9K A9K A9K A9K A9K Width in 9-mm modules 8 Accessories Padlocking device cat. no. 970
8 9 Technical Data Main characteristics Terminals insulated to IP0 Insulation voltage (Ui) Degree of pollution Rated impulse withstand voltage (Uimp) 0 V kv Test button: used to check that the residual current device is operating correctly Clip on DIN rail mm. Making and breaking capacity (lm/l m Lc) Impulse current withstand (8/0 µs) without dripping Conditional rated short-circuit current (lm/l m Lc) - 0 A 00 A A 0 A With circuit break With fuse Up to 00 Â 000 A 00 A Behaviour in case of voltage drop Residual current protection down to 0 V according to IEC/EN 008-.. Indication of the earth fault on the front panel by the position of the handle Large space for marking circuits Indifferent position of installation. Additional characteristics Degree of protection Endurance (O-C) Device only Device in modular enclosure Electrical Mechanical IP0 IP0 Insulation class II 000 cycles (AC) 000 cycles Operating temperature AC type - C to + C IP0 Storage temperature Tropicalization (IEC 008-) - C to +8 C Treatment (relative humidity 9% at C) Downstream by Biconnect comb busbar Upstream/downstream by tunnel terminals IP0 Weight (g) Residual current circuit breakers Type P P ID K Biconnect 80 0 Dimensions (mm) Common characteristics Type Tightening torque IDK Biconnect. N.m mm. mm Copper cables Rigid to mm PZ Flexible or with ferrule to mm
0 IEC/EN 008- The offer the following functions: Protection of persons against electric shock by direct contact (0 ma) Protection of persons against electric shock by indirect contact (> 00 ma) Protection of installations against the risks of fire (00 ma) Product Reference Type P AC a Sensitivity Rating P Width in 9 mm modules 0 ma 00 ma 00 ma A A9KRS - A9KR 0 A A9KR0S A9KR0 A9KR0 A A9KRS A9KR A9KR A9KR0S A9KR0 A9KR0 Sensitivity 0 A Rating 8 A A9KRS P 0 V P V Operating voltage (Ue) Operating frequency A9KR A9KR About Schneider Electric 0 Hz Schneider Electric is the global specialist in energy management and automation. With revenues of ~ 7 billion in FY0, our 0,000+ employees serve customers in over 00 countries, helping them to manage their energy and process in ways that are safe, reliable, efficient and sustainable. From the simplest of switches to complex operational systems, our technology, software and services improve the way our customers manage and automate their operations. Our connected technologies reshape industries, transform cities and enrich lives. At Schneider Electric, we call this Life Is On.
Schneider Electric 0 Ang Mo Kio Street #0-7/0 TechPoint Singapore 9 09 Phone: + 8 7877 www. April 0 0 Schneider Electric. All Rights Reserved. All trademarks are owned by Schneider Electric SE, its subsidiaries and affiliated companies.