DPX moulded case circuit breakers

Similar documents
DPX 1600 Electronic release

DPX 630 Electronic release

DPX 630 Thermal magnetic and trip-free switches DPX-I 630

Vistop TM isolating switches 63 to 160A

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

DPX 160 Thermal magnetic and trip-free switches DPX-I 160

New DMX 3. Efficient protection up to A AIR CIRCUIT BREAKERS PRODUCT GUIDE

DPX earth leakage DPX 3 -I earth leakage

DPX Thermal magnetic and trip-free switches DPX 3 -I 160

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Magnetic only

WORKSHOP SPECIFICATIONS

(p. 47) (p. 155) (p. 155)

Thermal magnetic and trip-free switches

DPX Electronic + earth leakage

price list IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Power protection solutions

cor Long Run Experience

DMX 3 -I 2500 switch disconnectors

DPX Electronic. Fiche technique : F01362EN/02 Mise à jour le : 15/12/2011 Créé le : 15/06/2011

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Phase + Neutral, neutral on left side

PRICE LIST THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

New DX 3 High rating & breaking capacity

Phase + Neutral, neutral on right side

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

COMPLETE SOLUTIONS FOR POWER PROTECTION

Breaking and protection devices

DX³ 4-pole RCBO 6000 A/10 ka

3 - Protection components Motor circuit-breakers

NEW TX³ RANGE PROTECTION YOU CAN RELY ON

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

CABINETS AND ENCLOSURES. XL³ 400 and XL³ 800 GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

TX³ RCCBs 2P up to 100 A

Low voltage Direct Current Network. Compact NSX DC PV. Circuit breakers and switch disconnectors for solar application.

(1,5 modules per pole)

Characteristics of LV circuit breakers Releases, tripping curves, and limitation

P. 07 DMX³ ACB from 630 A to 6300 A. P. 11 DMX SP 2500 ACB 630 A to 2500 A. P. 14 DRX MCCBs

87045 LIMOGES Cedex. 2. PRODUCT RANGE (continued) 1. DESCRIPTION - USE. Breaking capacity : Symbol : Technology : 3. OVERALL DIMENSIONS

DX³ RCBO 4500/6 ka Phase + Neutral, neutral on left


LEXIC Curv LIMOGES Cedex. Cats N (s) : /68/87/88, /48, /84/85, /76/77/95/96/97, /71/72 1.

DX³ RCBO 6000 A Phase + Neutral, neutral right side

DX³ RCCBs - ID 4P up to 100 A

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Get detailed information on many digital or printed supports, or contact your Area Commercial Manager

Essential equipment for all your requirements

Protection components

01 Spectra Plus - Introduction

schneider-electric.com/sg K60 Circuit Breakers The affordable way to stay safe from electrocution and electrical overloads schneider-electric.

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

Cat. N (s) : /65/66/83/84, /94/95/96/99, /01/02/06/07/11/12/13/14. Pollution degree : C / + 40 C. .

DX³ RCBO 6000A Phase + Neutral, neutral on left

RX 3 MCB 4500 A Phase + Neutral, neutral on left side

DCX-M. changeover switches ->CATALOGUE PAGES INSIDE THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

Wall mounted switchgear

MCBs and RCDs LR TM 6000

C60H-DC C curve. Catalogue numbers

DRX 125 Circuit breaker (not adjustable)

Cat N 3. OVERALL DIMENSIONS

DRX 250 B/N/H Circuit breaker (not adjustable)

Btdin RCBO 6000A up to 63A (2P)

Compact NR630. NR100F to NR630F

C 1. SPECTRONIC SP - Air circuit breakers. Summary. C2. General characteristics. C3. Fixed circuit breaker. C4. Withdrawable circuit breakers

DRX 100 B/N/H Circuit breaker (not adjustable)


DX³ RCBO 6000 / 10 ka Phase + Neutral, neutral on left

R.C.B.O. SP / 1 module

ATyS d M Remotely operated Transfer Switching Equipment from 40 to 160 A

Equipment model: auxiliary control. Pack Cat.Nos 10/16 A V± P + T shuttered module module

Specification for 70mm pole pitch Air circuit breaker up to 1600 A

dx 3 protection that meets your requirements GloBal SpecialiSt IN electrical AND DIgITAl BUIlDINg INFrASTrUCTUreS catalogue pages inside

C1251N DC and C1251N 1000 V

Low Voltage. EasyPact CVS. Moulded-case circuit breakers from 16 to 100 A

DX³ RCBO 6000A Phase + Neutral, neutral on right

DX 3 MCBs. Choice of DX 3 MCBs for capacitor banks. Technical data

LV switch-disconnectors. Interpact Merlin Gerin 40 to 2500 A. Catalogue. We do more with electricity

MCCB Accessories to suit AF

ATyS range ATyS r, ATyS d, ATyS t, ATyS g, ATyS p from 125 to 3200 A

GE Consumer & Industrial. M-PACT New Air Circuit Breaker A

Btdin-RS RCBO 2p Phase + Neutral, neutral on right

Circuit breakers and switch-disconnectors NT06 to NT16 and NW08 to NW63

up to 63 A (1 module per pole)

COMMERCIAL INFORMATION TECHNICAL INFORMATION BA511*33

MOULDED CASE CIRCUIT BREAKERS BC160N

C60H-DC. C curve IEC Direct current (DC) Breaking capacity (Icu) according to IEC Type 1P 110 V 220 V 250 V 440 V 500 V

SIDERMAT Load break switches for power distribution from 250 to 1800 A with tripping function

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

125 to 4000 A. Functions. Conformity to standards. Approvals and certifications (1) General characteristics. Available on request

Overview of Low voltage equipment - Moulded-case & Air circuit-breakers

ATyS. 63 to 3200 A. Functions. Conformity to standards. General characteristics. Changeover switches. Functions

Contents. Acti 9 MCBs, RCCB. ic60h circuit breakers (curve B, C, D)... pages 2/2 to 2/4. ic60h and ic60h2 RCB0 10, 30 and 100 ma...

An innovative technology

XL Distribution enclosures WORKSHOP SPECIFICATIONS

Btdin RCD Add-on modules 125A for MCBs 1,5 modules per pole

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

Transcription:

BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers DPX moulded case circuit breakers offer optimum solutions for the protection requirements of commercial and industrial installations. They can be installed: - On 2 rail or plate up to 250 A - On plate up to 1600 A THE DPX RANGE Mounting on 2 rail (or plate) with modular faceplate Mounting on plate with special faceplate DPX 125 DPX 160 DPX 250 ER DPX 250 DPX 630 DPX 1600 Thermal-magnetic releases Thermal-magnetic and electronic releases Ratings from 16 to 250 A Ratings from 63 to 1600 A Circuit breakers are available in thermal magnetic and electronic versions with nominal currents from 16 to 1600 A and breaking capacities from 16 to 70 ka. The main characteristics of DPX circuit breakers are their optimised dimensions, their ease of installation, use and accessorisation, and their undisputed reliability. DPX 125, 160 and 250 ER and their side-mounted earth leakage modules can be installed on a 2 rail and under a modular faceplate with window. Height spacer Cat. No. 262 99 can be used to combine modular circuit breakers and DPX on the same rail. The DPX range also includes DPX-I trip-free circuit breakers (see p. 121) 1

1 THERMAL MAGNETIC DPX Circuit breakers equipped with thermal magnetic releases are used to set the thermal intervention thresholds for protection against overloads and the magnetic intervention thresholds for protection against short-circuits. The magnetic threshold setting option is available on all devices from the DPX 250 upwards. This threshold is fixed on equipment for DIN rail mounting (DPX 125, DPX 160 and DPX 250 ER). Thermal magnetic DPXs are available from 16 to 1250 A with breaking capacities from 16 to 70 ka. 2 ELECTRONIC DPX DPXs equipped with microprocessor-based electronic releases offer the option, depending on the version, of precise setting of both the time and current intervention thresholds for overloads, short-circuits and also for earth faults. Electronic DPXs are available from 40 to 1600 A with breaking capacities from 36 to 100 ka. Electronic releases are available in 2 versions: - S1: adjustment of Ir and Im - S2: adjustment of Ir, Tr, Im and Tm DPX-H 630 - Electronic release Sg Identification of the type - Yellow DPX - H Electrical performance and standard references Characteristics - Cat No. - Breaking capacity - Nominal current (rating) - Standard Trip indicator lamps Marker holders Adjustment of the neutral (0-0.5-1) Indicator lamps - Green: normal operation - Continuous red: I < 0,9 Ir - Flashing red: I > 1,05 Ir Test button Setting the releases (cf. p. 59) Test socket Dynamic selectivity - Low - High Sealing of settings 2

BREAKING AND PROTECTION DEVICES 10 / 2011 DPX moulded case circuit breakers (continued) CHARACTERISTICS DPX-E 125 DPX 125 DPX 160 DPX 250 ER Number of poles 1P 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 Type of MCCB 16 ka 16 ka 25 ka 36 ka 25 ka 36 ka 50 ka 25 ka 36 ka 50 ka Nominal rating In (A) 16-125 16-125 16-125 16-125 63-160 63-160 40-160 100-250 100-250 100-250 Rated insulation voltage Ui (V) 290 500 500 500 500 500 500 500 500 500 Rated impulse withstand voltage Uimp (kv) 6 6 6 6 6 6 6 6 6 6 Rated operating voltage Ue (V) AC 50/60 Hz 230 500 500 500 500 500 500 500 500 500 DC (1) 250 250 250 250 250 250 250 250 250 230/240 V AC 16 22 35 40 40 50 65 40 50 65 Ultimate 400/415 V AC 16 25 36 25 36 50 25 36 50 breaking 440 V AC 10 18 20 20 25 30 20 25 30 capacity Icu 480/500 V AC 8 12 14 10 12 15 10 12 15 (ka) 600 V AC 690 V AC 2 poles in series 250 V DC (1) 16 25 30 25 36 25 36 Service breaking capacity Ics (% Icu) 50 100 50 75 100 75 50 100 75 50 Rating closing capacity on short circuit Icm (ka) at 400 V AC 32 32 52.5 75.6 52.5 75.6 105 52.5 75.6 105 Category of use A A A A A A A A A A Isolation capability thermal magnetic Release electronic S1 electronic S2 Earth leakage side by side modules (2) underneath Endurance (o.c. cycle) Dimensions L x H x D (mm) Weight (kg) mechanical 25000 25000 25000 20000 20000 20000 20000 20000 20000 electrical (at In) 8000 8000 8000 8000 8000 8000 8000 8000 8000 electrical (at 0.5 In) 10000 10000 10000 10000 10000 10000 10000 10000 10000 1P 25 x 120 x 74 3P 75.6 x 120 x 74 90 x 150 x 74 90 x 176 x 74 4P 101 x 120 x 74 120 x 150 x 74 120 x 176 x 74 3P 1 1.2 1.2 4P 1.2 1.6 1.6 (1) For voltages greater than 250 V DC: please contact us (2) Above 630 A, use of a relay with separate cores 3

DPX 250 DPX 250 electronic DPX 630 DPX 630 electronic DPX 1250 DPX 1600 electronic 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 3P - 4P - 3P+N/2 36 ka 70 ka 36 ka 70 ka 36 ka 70 ka 36 ka 70 ka 100 ka 50 ka 70 ka 50 ka 70 ka 40-250 40-250 40-250 40-250 250-630 320-630 250-630 400-630 400-630 800-1250 800-1250 800-1600 800-1600 690 690 690 690 690 690 690 690 690 690 690 690 690 8 8 8 8 8 8 8 8 8 8 8 8 8 690 690 690 690 690 690 690 690 690 690 690 690 690 250 250 - - 250 250 - - - 250 250 - - 60 100 60 100 60 100 60 100 170 80 100 80 100 36 70 36 70 36 70 36 70 100 50 70 50 70 30 60 30 60 30 60 30 60 70 65 65 25 40 25 40 25 40 25 40 35 35 20 25 20 25 20 25 20 25 28 25 35 25 35 16 20 16 20 16 20 16 20 22 20 25 20 25 36 40 36 40 50 50 100 75 100 75 100 75 100 75 50 100 75 100 75 75.6 154 75.6 154 75.6 154 75.6 154 220 105 154 105 154 A A A A A A A(250-400) / B(630 A) A A A A 20000 20000 20000 20000 15000 15000 15000 15000 15000 10000 10000 10000 10000 8000 8000 8000 8000 5000 5000 5000 5000 5000 4000 4000 3000 3000 10000 10000 10000 10000 8000 8000 8000 8000 8000 8000 8000 6000 6000 105 x 200 x 105 105 x 200 x 105 140 x 260 x 105 140 x 260 x 105 210 x 320 x 140 210 x 320 x 140 140 x 200 x 105 140 x 200 x 105 183 x 260 x 105 183 x 260 x 105 280 x 320 x 140 280 x 320 x 140 2.5 2.5 from 4.5 to 5.8 from 5.3 to 5.8 18 18 3.7 3.7 from 6.4 to 7.4 from 6.8 to 7.4 23.4 23.4 4

DPX TM 125 thermal magnetic MCCBs from 16 to 125 A 250 18 250 59 262 01 Dimensions (p. 88) Electrical characteristics (p. to 103) 250 + 260 13 MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 86) Can be used with earth leakage modules or with residual current relays (p. 87) Supplied complete with: - cage terminals 70 mm 2 max. - terminal shields Thermal release adjustable from 0.7 to 1 In and sealable Fixed magnetic at 10 In in factory (p. 96) Conform to IEC 607-2 Can be mounted on rail 2 or on plate in XL 3 cabinets and enclosures Pack Cat.Nos DPX-E 125 - fixed version Breaking capacity Icu 16 ka (230 V±) 1P In 1 250 00 16 A 1 250 01 20 A 1 250 02 25 A 1 250 03 32 A 1 250 04 40 A 1 250 05 50 A 1 250 06 63 A 1 250 07 80 A 1 250 08 100 A 1 250 09 125 A Breaking capacity Icu 16 ka (400 V±) 1 250 16 250 24 16 A 1 250 17 250 25 25 A 1 250 18 250 26 40 A 1 250 19 250 27 63 A 1 250 20 250 28 100 A 1 250 21 250 29 125 A 3P + N/2 In 1 250 23 125 A DPX 125 - fixed version Breaking capacity Icu 25 ka (400 V±) 1 250 36 250 44 16 A 1 250 37 250 25 A 1 250 38 250 46 40 A 1 250 39 250 47 63 A 1 250 40 250 48 100 A 1 250 41 250 49 125 A 3P + N/2 In 1 250 43 125 A Breaking capacity Icu 36 ka (400 V±) 1 250 50 250 58 16 A 1 250 51 250 59 25 A 1 250 52 250 60 40 A 1 250 53 250 61 63 A 1 250 54 250 62 100 A 1 250 55 250 63 125 A 3P + N/2 In 1 250 57 125 A Pack Cat.Nos Electronic earth leakage modules Can be fitted onto DPX/DPX-I 125 Adjustable, sealable sensitivity: 0.03-0.3-1 - 3 A Adjustable, tripping: 0-0.3-1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) 230-500 V± Mounted side by side (at right-hand side) 1 260 02 260 03 63 A 1 260 12 260 13 125 A Mounted underneath 1 260 04 63 A 1 260 14 125 A Rotary handles Direct on DPX 1 262 01 Standard (grey) 1 262 03 For emergency use (red/yellow) Vari-depth handle IP 55 Comprising: connection rod, bracket, drilling template, fixing accessories, door lock mechanism 1 262 75 Standard (grey) 1 262 76 For emergency use (red/yellow) Locking accessories 1 262 92 Eurolocks for vari-depth handle 1 262 93 Profalux for vari-depth handle 1 262 Ronis for vari-depth handle 1 262 25 Eurolocks for direct handle Accessories 3P 4P Sealable terminal shields 1 262 05 262 06 Set of 2 Rear terminals Used to connect fixed version with front terminals into fixed version with rear terminal 1 263 00 263 01 Set of upstream or downstream rear terminals 5

DPX TM 160 thermal magnetic MCCBs from 40 to 160 A 251 25 251 72 262 11 Dimensions (p. 89) Electrical characteristics (p. - 103) 251 33 + 260 21 MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 86) Can be used with earth leakage modules or with residual current relays (p. 87) Supplied complete with: - connection plates for bars - upstream and downstream connection devices for lugs (max. width 20 mm) - terminal shields Conform to IEC 607-2 Can be mounted on rail 2 or on plate in XL 3 cabinets and enclosures Pack Cat.Nos Fixed version Thermal adjustable from 0.64 to 1 In and sealable Fixed magnetic at 10 In in factory (p. 96) Breaking capacity Icu 25 ka (400 V±) 1 251 23 251 31 63 A 1 251 24 251 32 100 A 1 251 25 251 33 160 A 3P + N/2 In 1 251 27 160 A Breaking capacity Icu 36 ka (400 V±) 1 251 49 251 57 63 A 1 251 50 251 58 100 A 1 251 51 251 59 160 A 3P + N/2 In 1 251 53 160 A Breaking capacity Icu 50 ka (400 V±) 1 251 62 251 70 40 A 1 251 63 251 71 63 A 1 251 64 251 72 100 A 1 251 65 251 73 160 A 3P + N/2 In 1 251 67 160 A Supply invertor type Mounting plate 1 264 01 For mechanical interlocking of 2 DPX of the same size for use in normal or automatic modes Electronic earth leakage modules Can be fitted onto DPX/DPX-I 160 Adjustable, sealable sensitivity: 0.03-0.3-1 - 3 A Adjustable, tripping: 0-0.3-1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) 230-500 V± 3P 4P Mounted side by side (at right-hand side) 1 260 20 260 21 160 A Mounted underneath 1 260 22 160 A Pack Cat.Nos Rotary handles Direct on DPX 1 262 11 Standard (grey) 1 262 13 For emergency use (red/yellow) Vari-depth handle IP 55 Comprising: connecting rod, bracket, drilling template, fixing accessories, door lock mechanism 1 262 77 Standard (grey) 1 262 78 For emergency use (red/yellow) Locking accessories 1 262 92 Eurolocks for vari-depth handle 1 262 93 Profalux for vari-depth handle 1 262 Ronis for vari-depth handle 1 262 25 Eurolocks for direct handle Accessories 3P 4P Sealable terminal shields 1 262 15 262 16 Set of 2 Cage terminals Set of 4 1 262 18 For cable without lug 95 mm 2 (rigid) or 70 mm 2 (flexible) 1 262 19 For cable without lug 120 mm 2 (rigid) or 95 mm 2 (flexible) Adaptator for lug 1 262 17 Set of 4 (upstream or downstream) Supplied with insulated shield Rear terminals Used to connect a fixed version with front terminals into fixed version with 3P 4P rear terminals 1 263 10 263 11 Set of upstream and downstream rear terminals Mounting accessories and common accessories (p. 77) 6

DPX TM 250 ER thermal magnetic MCCBs from 100 to 250 A 252 55 252 56 + 260 36 Protective cover for Cat.No 265 13 265 17 262 11 Dimensions (p. 90) Electrical characteristics (p. - 103) MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 86) Can be used with earth leakage modules or with residual current relays (p. 87) Supplied complete with: - connection plates for bars - upstream and downstream connection devices for lugs (max. width 20 mm) - terminal shields Can be mounted on rail 2 or on plate in XL 3 cabinets and enclosures Conform to IEC 607-2 Pack Cat.Nos Fixed version Pack Cat.Nos Electronic earth leakage modules Thermal adjustable from 0.64 to 1 In and sealable Fixed magnetic at 10 In in factory (p. 96) Breaking capacity Icu 25 ka (400 V±) 1 252 04 252 14 100 A 1 252 05 252 15 160 A 1 252 06 252 16 250 A 3P + N/2 In 1 252 09 250 A Breaking capacity Icu 36 ka (400 V±) 1 252 24 252 34 100 A 1 252 25 252 35 160 A 1 252 26 252 36 250 A 3P + N/2 In 1 252 29 250 A Breaking capacity Icu 50 ka (400 V±) 1 252 44 252 54 100 A 1 252 252 55 160 A 1 252 46 252 56 250 A 3P + N/2 In 1 252 49 250 A Plug-in version A plug-in is a DPX fitted with tulip contacts mounted on a base 3P 4P Tulip contacts 1 265 12 265 13 Set of tulip contacts (supplied with an incoming/outgoing protective cover) Bases Can accept DPX and DPX-I fitted with tulip contacts For DPX only 1 265 14 265 15 Front terminal mounting base 1 265 16 265 17 Rear terminal mounting base Connectors For connecting the auxiliaries included in the DPX 1 263 99 Set of connectors (8-pin) Supply invertor type Mounting plate 1 264 02 For mechanical interlocking of 2 DPX of the same size for use in normal or automatic modes Can be fitted onto DPX/DPX-I 250 ER Adjustable, sealable sensitivity: 0.03-0.3-1 - 3 A Adjustable, tripping: 0.03-0.3-1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) 4P Mounted side by side (at right-hand side) 1 260 31 160 A 1 260 36 250 A Mounted underneath 1 260 33 160 A 1 260 38 250 A Rotary handles Direct on DPX 1 262 11 Standard (grey) 1 262 13 For emergency use (red/yellow) Vari-depth handle IP 55 Comprising: connecting rod, bracket, drilling template, fixing accessories, door lock mechanism 1 262 77 Standard (grey) 1 262 78 For emergency use (red/yellow) Locking accessories 1 262 92 Eurolocks for vari-depth handle 1 262 93 Profalux for vari-depth handle 1 262 Ronis for vari-depth handle 1 262 25 Eurolocks for direct handle Accessories 3P 4P Sealable terminal shields 1 262 85 262 86 Set of 2 Cage terminals 1 262 88 (1) Set of 4 For cable without lug 185 mm 2 (rigid) or 150 mm 2 (flexible) for DPX 250 ER and DPX-IS 250 3P 4P Spreaders 1 262 90 262 91 Set of incoming or outgoing spreaders Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals 1 265 10 265 11 Set of upstream and downstream rear terminals (1) Can not be mounted on side by side mounted earth leakage modules 160 A 7

DPX TM 125, 160 and 250 ER mounting accessories DPX TM 125, 160 and 250 ER connection Connection DPX front terminals Connection with cables Connection with bars Ø D 262 08 048 67 6 Nm 6 Nm DPX 125 160 250 ER max. Ø 12 18 18 DPX 125 160 250 ER D 12 18 18 Plug-in version (only DPX 250 ER) Front terminals Rear terminals 048 68 262 00 Pack Cat.Nos Fixing plates For fixing devices on rail 1 262 08 For DPX 125 1 262 09 For DPX 160/250 ER Insulated shields Insulated shields Used to isolated the connection between each pole 1 262 07 Set of 3 Distribution terminals 1 048 67 160 A - 6 outputs 25 mm 2 flexible - Isc peak 30 kâ Can be fitted directly onto downstream terminal of DPX 165/160, Vistop 100/160 A and DX H 125 A 1 048 68 250 A - 4 outputs 35 mm 2 flexible and 2 outputs 25 mm 2 flexible- Isc peak 36 kâ Can be fitted directly onto downstream terminal of DPX 250/250 ER and DX-IS 250 Padlocks For locking in "off" position 1 262 00 For DPX 125 1 262 10 For DPX 160 and DPX 250 ER XL 3 mounting accessories (p. 202, 217 and 231) Mounting of distribution terminal 8

DPX TM 250 thermal magnetic and electronic release MCCBs from 40 to 250 A 253 49 253 52 254 23 Dimensions (p. 91) Electrical characteristics (p. - 103) Moulded case MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 86) Can be used with earth leakage modules (opposite) or with residual current relays (p. 87) Supplied complete with: - connection plates for bars - upstream and downstream connection devices for lugs (width max. 20 mm) - terminal shields Conform to IEC 607-2 Sealable adjustment Can be mounted on plate in XL 3 cabinets and enclosures Pack Cat.Nos DPX 250 thermal magnetic Thermal adjustable from 0.64 to 1 In Magnetic adjustable from 3.5 to 10 In t Ir DPX 250 36 ka Breaking capacity Icu 36 ka (400 V±) 1 253 28 253 40 A 1 253 29 253 46 63 A 1 253 30 253 47 100 A 1 253 31 253 48 160 A 1 253 32 253 49 250 A 3P + N/2 In 1 253 41 160 A 1 253 42 250 A DPX-H 250 70 ka Breaking capacity Icu 70 ka (400 V±) 1 253 52 253 69 40 A 1 253 53 253 70 63 A 1 253 54 253 71 100 A 1 253 55 253 72 160 A 1 253 56 253 73 250 A 3P + N/2 In 1 253 66 250 A Im I Pack Cat.Nos DPX 250 electronic release S1 Adjustment of Ir and Im (p. 96) Instantaneous protection If = 4 ka Indicator lamp Minimum current for indicator lamp operation (30 % of In) - green: normal - fixed red: I 0.9 Ir - flushing red: I 1.05 Ir Connector for test unit Dynamic selectivity 4P version: adjustment of neutral on front panel t Ir DPX 250 36 ka Breaking capacity Icu 36 ka (400 V±) 1 254 01 254 07 40 A 1 254 03 254 09 100 A 1 254 04 254 10 160 A 1 254 05 254 11 250 A DPX-H 250 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 254 13 254 19 40 A 1 254 15 254 21 100 A 1 254 16 254 22 160 A 1 254 17 254 23 250 A Im If I 9

DPX TM 250 thermal magnetic and electronic release MCCBs from 40 to 250 A (continued) 260 55 260 53 265 32 265 46 Pack Cat.Nos DPX 250 electronic release S2 Adjustment of Ir, Im, Tr, Tm (p. 96) Instantaneous protection If = 4 ka Indicator lamp Minimum current for indicator lamp operation (30 % of In) - green: normal - fixed red: I 0.9 Ir - flushing red: I 1.05 Ir Connector for test unit Dynamic selectivity 4P version: adjustment of neutral on front panel t Ir Im Tm I DPX 250 36 ka Breaking capacity Icu 36 ka (400 V±) 1 254 40 254 40 A 1 254 41 254 46 100 A 1 254 42 254 47 160 A 1 254 43 254 48 250 A DPX-H 250 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 254 50 254 55 40 A 1 254 51 254 56 100 A 1 254 52 254 57 160 A 1 254 53 254 58 250 A Electronic earth leakage modules Can be fitted onto DPX/DPX-I 250 Adjustable, sealable sensitivity: 0.03-0.3-1 - 3 A Adjustable, time delay: 0-0.3-1 - 3 s Test push-buttons Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) Mounted underneath Standard 1 260 51 160 A 1 260 54 260 55 250 A LED version Monitors the isolation state of the installation via a series of LEDs 4P In 1 260 53 160 A 1 260 57 250 A Tr Pack Cat.Nos Plug-in version A plug-in is a DPX fitted with tulip contacts mounted on a base 3P 4P Tulip contacts 1 265 29 265 30 Set of tulip contacts (supplied with an incoming/outgoing protective cover) Bases for DPX only Accept DPX/DPX-I fitted with tulip contacts 1 265 31 265 32 Front terminal mounting base 1 265 33 265 34 Rear terminal mounting base with threaded rod 1 265 35 265 36 Flat rear terminal mounting base Bases for DPX with earth leakage 4P module 1 265 37 Front terminal mounting base 1 265 38 Rear terminal mounting base with threaded rod 1 265 39 Flat rear terminal mounting base Accessories 1 263 99 Set of connectors (8-pin) 1 098 19 Set of connectors (6-pin) 1 263 43 Set of 2 extractor handle Draw-out version A DPX draw-out version is a plug-in DPX fitted with a "Debro-lift" mechanism which can be used to withdraw the DPX while keeping it on its base "Debro-lift" mechanism Supplied with a rigid slide and handle for 3P 4P drawing-out 1 265 265 46 For DPX base only 1 265 47 For DPX base with earth leakage module Key lock for "Debro-lift" mechanism Enable locking of DPX in drawn-out position 1 265 76 1 key Ronis for DPX only 1 265 78 1 key Ronis for motorised DPX or with rotary handle Accessories for "Debro-lift" mechanism 1 265 75 Isolated handle for drawing-out 1 265 74 Signalling contact (plugged-in/drawn-out) Supply invertor type A supply invertor type is composed of one plate with interlock for 2 devices 1 264 08 Plate for MCCB or trip-free switch fixed version 1 264 03 Plate for MCCB or trip-free switch plug-in and draw-out version Red catalogue numbers : New products 10

DPX TM 250 equipment and accessories 262 22 262 79 262 80 261 30 Pack Cat.Nos Rotary handles Direct on DPX 1 262 22 Standard (grey) 1 262 24 For emergency use (red/yellow) - can be fitted on Cat.Nos 262 22, 262 41 or 262 81 Vari-depth handle IP 55 Comprising: connection rod, bracket, self-adhesive drilling template, mounting accessories and door lock mechanism 1 262 79 Standard (black) 1 262 80 Conversion kit for emergency use Can be fitted on Cat.No 262 79 Locking accessories 1 262 92 Eurolocks for vari-depth handle 1 262 93 Profalux for vari-depth handle 1 262 Ronis for vari-depth handle 1 262 25 Eurolocks for direct handle Motor-driven handles Front operated 1 261 30 24 V±/= 1 261 34 230 V± Accessory 1 261 59 Ronis locking accessory Pack Cat.Nos Accessories Insulated shields 1 262 30 Set of 3 3P 4P Sealable terminal shields 1 262 26 262 27 Set of 2 long terminal shields 1 262 28 262 29 Set of 2 short terminal shields Padlock 1 262 21 For locking in "open" position Cage terminals 1 262 35 Set of 4 terminals for cable 185 mm 2 max. or 150 mm 2 max. (flexible) Adaptor for lug For connecting bare cables with wide lug 1 262 31 Set of 1 adaptor + insulated shields Extended front terminals 1 262 32 Set of 4 3P 4P Spreaders 1 262 33 262 34 Set of spreaders incoming or outgoing Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals 1 263 31 263 32 Set of rear terminals, incoming or outgoing 1 265 27 265 28 Set of flat rear terminals, incoming or outgoing Distribution terminal 250 A 1 048 68 250 A - 4 outputs 35 mm 2 flexible and 2 outputs 25 mm 2 flexible - Isc peak 36 kâ Can be fitted directly onto downstream terminal of DPX 250/250 ER and DPX-IS 250 11

DPX TM 630 thermal magnetic and electronic release MCCBs from 250 to 630 A Green indicator lamp (only S1): normal operation minimum current for indicator lamp operation (30 % of In) Fixed red indicator lamp: 0.9 Ir Flushing red indicator lamp: I 1.05 Ir connector for test unit 255 40 255 53 256 07 Dimensions (p. 92) Electrical characteristics (p. - 103) Moulded case MCCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (p. 86) Can be used with earth leakage modules or with residual current relays (p. 87) Supplied complete with: - connection plates for bars - terminal shields Conform to IEC 607-2 - Sealable adjustment Can be mounted on plate in XL 3 cabinets and enclosures Pack Cat.Nos DPX 630 thermal magnetic Thermal adjustable from 0.8 to 1 In Magnetic adjustable from 5 to 10 In t Ir I DPX 630 36 ka Breaking capacity Icu 36 ka (400 V±) 1 255 21 255 36 250 A 1 255 22 255 37 320 A 1 255 23 255 38 400 A 1 255 25 255 39 500 A 1 255 24 255 40 630 A 3P + N/2 In 1 255 32 320 A 1 255 33 400 A 1 255 35 500 A 1 255 34 630 A DPX-H 630 70 ka Breaking capacity Icu 70 ka (400 V±) 1 255 42 255 57 320 A 1 255 43 255 58 400 A 1 255 255 59 500 A 1 255 44 255 60 630 A 3P + N/2 In 1 255 52 320 A 1 255 53 400 A 1 255 55 500 A 1 255 54 630 A Im Pack Cat.Nos DPX 630 electronic release S1 Adjustment of Ir, Im, (p. 96) Instantaneous protection If = 5 ka Green indicator lamp Connector for test unit Dynamic selectivity 4P version: adjustement of neutral on front panel t Ir Im If I DPX 630 36 ka Breaking capacity Icu 36 ka (400 V±) 1 256 01 256 05 250 A 1 256 02 256 06 400 A 1 256 03 256 07 630 A DPX-H 630 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 256 10 256 14 400 A 1 256 11 256 15 630 A 12

DPX TM 630 thermal magnetic and electronic release MCCBs from 250 to 630 A (continued) DPX TM 630 Performance data S1 - Adjustment of Ir, Im t Ir Im If I 256 35 260 63 Pack Cat.Nos DPX 630 electronic release S2 Adjustment of Ir, Im, Tr, Tm (opposite) Instantaneous protection If = 5 ka Green indicator lamp Connector for test unit Logic and dynamic selectivity 4P version: adjustement of neutral on front panel t Ir Tr Im Tm I DPX 630 36 ka Breaking capacity Icu 36 ka (400 V±) 1 256 26 256 30 250 A 1 256 27 256 31 400 A 1 256 28 256 32 630 A DPX-H 630 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 256 35 256 39 400 A 1 256 36 256 40 630 A DPX-L 630 100 ka Breaking capacity Icu 100 ka (400 V±) In 1 256 43 256 47 400 A 1 256 44 256 48 630 A based on the rms value of the current: Ir = 0.4-0.5-0.7-0.8-0.95-1 x In (8 steps) Tr = 5 s (fixed at 6 tr) threshold: Im = 1.5-2 - 3-4 - 5-6 - 8-10 x Ir (8 steps) Tm = 0.05 s (fixed) if with fixed threshold: If = 5 ka S2 - Adjustment of Ir, Tr, Im, Tm t Ir Tr Im Tm If I based on the rms value of the current: Ir = 0.4-0.5-0.7-0.8-0.9-0.95-1 x In (8 steps) Tr = 5-10 - 20-30 s (at 6 Ir) (4 steps) threshold: Im = 1.5-2 - 3-4 - 5-6 - 8-10 x Ir (8 steps) Tm = 0-0.1-0.2-0.3 s (4 steps) Tm = 0.01-0.1-0.2-0.3 s at 12 x Ir (I2 t constant) (4 steps) with fixed threshold: If = 5 ka Earth leakage modules Can be fitted onto DPX/DPX-I 630 Adjustable, sealable sensitivity: 0.03-0.3-1 - 3 A Adjustable, time delay: 0-0.3-1 - 3 s Test push-button Reset push-button Remote earth fault signalling contact Switch for mechanical tests (installation insulation test) Mounted underneath 230-500 V± Standard 1 260 60 260 61 400 A 1 260 64 260 65 630 A LED version Monitors the isolation state of the installation via a series of LEDs 4P In 1 260 63 400 A 1 260 67 630 A 13

DPX TM 630 equipment and accessories 265 57 265 67 262 50 262 51 262 48 Pack Cat.Nos Plug-in version A plug-in is a DPX fitted with tulip contacts mounted on a base 3P 4P Tulip contacts 1 265 50 265 51 Set of tulip contacts (supplied with an incoming/outgoing protective cover) Bases for DPX only Accept DPX/DPX-I fitted with tulip contacts 1 265 52 265 53 Front terminal mounting base 1 265 54 265 55 Rear terminal mounting base with threaded rod 1 265 56 265 57 Flat rear terminal mounting base 4P Bases for DPX with earth leakage module 1 265 58 Front terminal mounting base 1 265 59 Rear terminal mounting base with threaded rod 1 265 60 Flat rear terminal mounting base Accessories 1 263 68 Set of 2 extractor handle 1 263 99 Set of connectors (8-pin) Draw-out version A DPX draw-out version is a plug-in DPX fitted with a "Debro-lift" mechanism which can be used to withdraw the DPX while keeping it on its base "Debro-lift" mechanism Supplied with a rigid slide and handle for 3P 4P drawing-out 1 265 66 265 67 For DPX base only 1 265 68 For DPX base with earth leakage module Key-lock for "Debro-lift" mechanism Enable locking of DPX in drawn-out position 1 265 76 1 key Ronis for DPX only 1 265 78 1 key Ronis for motorised DPX or with rotary handle Accessories for "Debro-lift" mechanism 1 265 75 Isolated handle for drawing-out 1 265 74 Signalling contact (plugged-in/drawn-out) Supply invertor type Factory assembled A supply invertor type is composed of one plate with interlock for 2 devices 1 264 09 Plate for MCCB or trip-free switch fixed version 1 264 04 Plate for MCCB or trip-free switch plug-in and draw-out version Pack Cat.Nos Rotary handles (continued) Vari-depth handle IP 55 Comprising: connection rod, bracket, self-adhesive drilling template, mounting accessories and door lock mechanism 1 262 81 Standard (grey) 1 262 82 For emergency use (red/yellow) can be fitted on Cat.Nos 262 81 or 262 41 Locking accessories 1 262 92 Eurolocks for vari-depth handle 1 262 93 Profalux for vari-depth handle 1 262 Ronis for vari-depth handle 1 262 25 Eurolocks for direct handle Motor-driven handles Front operated 1 261 40 24 V±/= 1 261 44 230 V± Accessory 1 261 59 Ronis locking accessory Accessories Insulated shields 1 262 30 Set of 3 3P 4P Sealable terminal shields 1 262 44 262 Set of 2 Padlock 1 262 40 For locking in "OPEN" position Cage terminals 1 262 50 Set of 4 terminals for cable 300 mm 2 max. (rigid) or 240 mm 2 max. (flexible) 1 262 51 Set of 4 high-capacity terminals for cable 2 x 240 mm 2 (rigid) or 2 x 185 mm 2 (flexible) Adaptor for lug For connecting bare cables with wide lugs 1 262 46 Set of 4 adaptors + insulated shields Extended front terminals 1 262 47 Set of 4 3P 4P Spreaders 1 262 48 262 49 Set of incoming or outgoing spreaders Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals 1 263 50 263 51 Set of incoming or outgoing swivel terminals 1 263 52 265 53 Set of incoming or outgoing flat terminals Rotary handles Direct on DPX 1 262 41 Standard (grey) 1 262 24 For emergency use (red/yellow) - can be fitted on Cat.Nos 262 22, 262 41 or 262 81 14

DPX TM 1250-1600 thermal magnetic and electronic release MCCBs from 800 to 1600 A 258 04 257 08 Dimensions (p. 93) Electrical characteristics (p. - 103) Moulded case MCBs for switching, control isolation and protection of low voltage electrical lines Can be fitted with auxiliaries (integrated terminal blocks) Can be used with earth leakage modules or with residual current relays (p. 87) Supplied complete with: - connection plates for bars - terminal shields Conform to IEC 607-2 Fixed version - Sealable adjustment Pack Cat.Nos DPX 1250 thermal magnetic Thermal adjustable from 0.8 to 1 In Magnetic adjustable from: 5 to 10 In t Ir I DPX 1250 50 ka Breaking capacity Icu 50 ka (400 V±) 1 258 02 258 09 (1) 800 A 1 258 03 258 10 (1) 1000 A 1 258 04 258 11 (1) 1250 A DPX-H 1250 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 258 16 258 23 (1) 800 A 1 258 17 258 24 (1) 1000 A 1 258 18 258 25 (1) 1250 A Im Pack Cat.Nos DPX 1600 electronic release S1 Adjustment of Ir, Im Instantaneous protection If = 20 ka Indicator lamp Minimum current for indicator lamp operation (30 % In): green: normal; fixed red: I 0.9 Ir; flashing red: I 1.05 Ir Connector for test unit Dynamic selectivity DPX 1600 50 ka Breaking capacity Icu 50 ka (400 V±) 1 257 02 257 06 (2) 800 A 1 257 03 257 07 (2) 1250 A 1 257 04 257 08 (2) 1600 A DPX-H 1600 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 257 10 257 14 (2) 800 A 1 257 11 257 15 (2) 1250 A 1 257 12 257 16 (2) 1600 A DPX 1600 electronic release S2 Adjustment of Ir, Im, Tr, Tm Instantaneous protection If = 20 ka Indicator lamp Minimum current for indicator lamp operation (30 % In): green: normal; fixed red: I 0.9 Ir; flashing red: I 1.05 Ir Connector for test unit Logic and dynamic selectivity DPX 1600 50 ka Im Tm Breaking capacity Icu 50 ka (400 V±) 1 257 26 257 30 (2) 800 A 1 257 27 257 31 (2) 1250 A 1 257 28 257 32 (2) 1600 A DPX-H 1600 70 ka Breaking capacity Icu 70 ka (400 V±) In 1 257 34 257 38 (2) 800 A 1 257 35 257 39 (2) 1250 A 1 257 36 257 40 (2) 1600 A t t Ir Ir Tr Im If I I (1) Neutral without protection (2) Neutral settings 0-0.5-1 N (0-50% - 100% Neutral) 15

DPX TM 1250-1600 equipment and accessories 265 84 (supplied assembled) 262 60 262 70 262 67 + 262 68 Pack Cat.Nos Draw-out version A DPX draw-out version is a plug-in DPX fitted with a "Debro-lift" mechanism which can be used to withdraw the DPX while keeping it on its base Draw-out base Base for DPX 1600 supplied with "Debro-lift" assembled a rigid slide and 3P 4P handle for drawing-out 1 265 82 265 83 Front terminals 1 265 84 265 85 Rear terminals Key lock for "Debro-lift" mechanism Enable locking of DPX in drawn-out position 1 265 76 One key Ronis for DPX only 1 265 80 Two key Ronis (one key supplied) for motorised DPX or with rotary handle Accessories for "Debro-lift" mechanism 1 265 75 Isolated handle for drawing-out 1 265 74 Signalling contact (plugged-in/drawn-out) Supply invertor type A supply invertor type is composed of one plate with interlock for 2 devices 1 264 10 Plate for MCCBs or trip-free switch fixed version 1 264 05 Plate for MCCBs or trip-free switch plug-in and draw-out version Rotary handles Direct on DPX 1 262 61 Standard (black) Vari-depth handle IP 55 Comprising: connection rod, bracket, self-adhesive drilling template, mounting accessories and door lock mechanism 1 262 83 Standard (black) 1 262 84 For emergency use (red/yellow) Locking accessories 1 262 92 Eurolocks for vari-depth handle 1 262 93 Profalux for vari-depth handle 1 262 Ronis for vari-depth handle 1 262 25 Eurolocks for direct handle Pack Cat.Nos Motor-driven handles Factory assembled Front operated 1 261 54 230 V± Customer assembled Front operated 1 261 24 24 V±/= 1 261 25 48 V±/= 1 261 26 110 V±/= 1 261 23 230 V±/= for ratings up to 1250 A (In 1250 A) 1 261 27 230 V±/= for 1600 A (In 1600 A) Locking accessory 1 261 59 Ronis locking accessory Accessories Insulated shields Used to isolate the connections between each pole 1 262 66 Set of 3 3P 4P Sealable terminal shields 1 262 64 262 65 Set of 2 Padlock 1 262 60 For locking in "open" position Cage terminals 1 262 69 Set of 1 terminal for cables without lug 2 x 240 mm 2 for rigid cable or 2 x 185 mm 2 for flexible cable 1 262 70 Set of 1 high-capacity terminal for cables without lug 4 x 240 mm 2 for rigid cable 4 x 185 mm 2 for flexible cable Extended front terminals Set of 4 1 262 67 Short terminals for 630-1250 A (2 bars max. per pole) 1 262 68 Long terminals for 1600 A (3 bars max. per pole) 3P 4P Spreaders 1 262 73 262 74 Set of incoming or outgoing spreaders Rear terminals Used to convert the fixed version with front terminals to the fixed version with rear terminals Set of incoming or outgoing rear terminals 1 263 80 263 82 Short terminals 1 263 81 263 83 Long terminals Red catalogue numbers : New products 16

DPX TM auxiliaries DPX TM auxiliaries 261 85 261 93 Pack Cat.Nos Auxiliary contact or fault signal 1 261 60 For signalling the state of the contacts or opening of the MCCB on a fault For DPX/DPX-I/DPX-IS Changeover switch 3 A - 240 V± Auxiliary contact or fault signal A singly Cat.No 261 60 auxiliary contact or fault signal Releases Allow remote tripping of a DPX Shunt releases For DPX-IS/DPX-I and DPX Shunt inrush power 300 VA 1 261 64 Coil voltage 24 V±/= 1 261 65 Coil voltage 48 V±/= 1 261 66 Coil voltage 110 V±/= 1 261 67 Coil voltage 230 V±/= 1 261 68 Coil voltage 400 V±/= For DPX/DPX-I 160 Undervoltage releases DPX/DPX-I 125 250ER, 630, DPX-IS 250, 1250, 1600 and For DPX-IS/DPX-I and DPX 630 DPX-IS 1600 Undervoltage power consumption 5 VA 1 261 70 261 80 Coil voltage 24 V= 1 261 71 261 81 Coil voltage 24 V± 1 261 72 261 82 Coil voltage 48 V= 1 261 76 261 86 Coil voltage 110 V± 1 261 73 261 83 Coil voltage 230 V± 1 261 74 261 84 Coil voltage 400 V± Time-lag (ms) undervoltage releases Allow remote tripping of a DPX Prevent false tripping in the event of AC supply microbreaks Require a time-lag module connected to the undervoltage releases below Number of modules 1 261 90 Time-lag modules 230 V± 3 1 261 91 Time-lag modules 400 V± 3 1 261 75 Undervoltage releases For DPX/DPX-I 125, DPX -IS 250,630 1 261 85 Undervoltage releases For DPX/DPX-I 160, 250ER, 630, 1250, 1600 and DPX -IS 1600 Undervoltage releases Shunt releases Time-lag undervoltage releases Max. number of contacts per DPX-IS device Auxiliary contact Device AC EBAC FS Shunt release or undervoltage release Electronic test unit 1 261 97 Test connector and software for connecting DPX to a PC Supplied with test software Automation control unit For setting the conditions for supply inversion, generator on loft status acquisition for DMX and DPX circuitbreakers, open/closed Power supply: 230 V± and 12-24-48 V= Connection by plug-in terminals 1 261 93 Standard unit 1 261 Communicating unit, enabling data transmission (RS 485 port) Without release With release DPX-IS 250 1 2 DPX-IS 250 1 1 1 1 AC = auxiliary contact EBAC = "early" auxiliary contact FS = break on trip contact Max. number of contacts per DPX device Device Auxiliary contact AC FS Shunt release or undervoltage release DPX 125 1 1 1 DPX 160 1 1 1 DPX 250 ER 1 1 1 DPX 250 2 1 1 DPX 630 2 2 1 DPX 1600 3 1 1 17

residual current relay and coils residual current relay and coils Residual current relay Cat.No 260 88 60 35 6 44 88 35 90 260 88 260 98 260 93 coil for use with relay Add residual current protection to DPX trip-free switches and DPX MCCBs equipped with release Pack Cat.Nos Residual current relay Detects fault currents, and, when used with a shunt trip or an undervoltage release, it gives the trip command to a MCCB or a switch - a tinged, sealable window - an auxiliary contact - a green Led indicating energisation - 3 yellow Leds indicating respectively the max. phase earth insulation current: 20, 40 and 60 % - a red Led indicating Fixed: exceeding of the insulation fault current value Flashing: breaking of one of the connections between coils and relays - Ø35 and 80 mm Adjustable sensitivity: 0.03, 0.05, 0.075, 0.1, 0.15, 0.2, 0.3, 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A - Ø110 to 210 mm Adjustable sensitivity: 0.3, 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A - Ø150 mm Adjustable sensitivity: 0.5, 0.75, 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A - Ø300 mm Adjustable sensitivity: 1, 1.5, 2, 3, 5, 7.5, 10, 15, 20, 30 A Number of modules 1 260 88 Residual current relay to clip on rail 2 2 Coils For use with residual current relay Cat.No 260 88 1 coil per DPX 1 260 92 Coil Ø35 mm 1 260 93 Coil Ø80 mm 1 260 Coil Ø110 mm 1 260 95 Coil Ø140 mm 1 260 96 Coil Ø210 mm 1 260 97 Coil Ø150 mm - open 1 260 98 Coil Ø300 mm - open Coils Cat.Nos 260 92/93//95/96 Cat.No 260 97 5.5 A E B 6 5 22 L D 23 H C M Cat.Nos A B C D E H L M 260 92 35 75 85 42 92 36 43 56 260 93 80 108 132 67 125 36 65 56 260 110 148 170 86 165 36 84 56 260 95 140 177 206 104 200 36 102 56 260 96 210 270 295 150 290 44 1 64 260 97 150 225 259 133 2 275 95 113 Cat.No 260 98 A B E H 58 5 21 7 M D L C 79 34 Viking 3 disconnector block for measurement 1 connection With its accessories, allows intervention (measurement, maintenance, etc) on a current, voltage and power measuring circuit by keeping the current transformer secondary circuit closed Colour Nominal Capacity Pitch cross rigid Flexible (mm) section wire wire (mm 2 ) (mm 2 ) (mm 2 ) 25 371 92 Grey 4 0.25 to 4 0.25 to 4 8 310 368 400 30 Red catalogue numbers: New products 18

DPX TM 125 Dimensions Fixed version, front terminals 101 75.6 12 12 37.8 8 97 74 32 8 Fixed version, front terminals with earth leakage module mounted underneath 101 97 10 74 8 50.8 120 101 120 101 25.4 25.4 M4 32.25 Fixed version, rear terminals 75.6 101 97 74 8 Fixed version, rear terminals with earth leakage module mounted underneath 97 120 101 101 101 74 8 25.4 25.4 25.4 25.4 25.4 10 M8 M4 39 81 M8 Rotary handle-direct on DPX Fixed version, front terminals with earth leakage module mounted side by side (1) 202 101 101 37.8 25.4 10 97 74 Rotary handle-vari-depth on door Mounting with flexible seal 70 7 8 74 120 103 210 193 193 25.4 Ø 4.3 or M4 210 191 32.25 25.4 25.4 25.4 M4 39 81 Terminal shields A 10 DPX 125 170 DPX 125 + earth leakage module mounted underneath 260 A 25.4 75.5 80 12.7 103 40.2 11.2 60 8 74 48 M4 20 80 20 358.5 max. 173.5 min. (2) 0.8/2 103 12.7 113.7 8 M4 (1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage modules (2) 70 mm without mechanical system 62.5 19

DPX TM 160 Dimensions Fixed version, front terminals 90 120 8 97 74 8 23 Fixed version, front terminals with earth leakage module mounted underneath 120 30 89 97 150 265 247 Fixed version, rear terminals 90 120 97 Fixed version, rear terminals with earth leakage module mounted underneath Fixed version, front terminals with earth leakage module mounted side by side (1) Y 120 30 = = 240 120 M4 = 150 150 30 150 18 max. 30 M4 23 115 14 30 30 M4 23 74 8 Y 30 30 30 30 30 48 95 74 8 X 241 158 55 150 115 265 247 161 55.5 30 30 30 120 74 97 8 M10 M4 8 97 74 8 95 86 Rotary handle direct on DPX X 150 132 = 15 Y 135 30 60 Terminal shields Rotary handle-vari-depth on door Mounting with flexible seal A 8 48 95 30 M4 60 8 74 48 35 15 75.5 80 115 38.5 11.25 1.5 max. 5 70 M4 8 74 358.5 max. 141.5 min. (2) 0.8/2 A 115 DPX 160 278 DPX 160 + earth leakage module mounted underneath 393 62.5 (1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage modules (2) 70 mm without mechanical system 20

DPX TM 250 ER Dimensions Fixed version, front terminals Fixed version with earth leakage module mounted underneath Front terminals Rear terminals 90 120 30 30 30 M4 10 max. 8 18 Ømax. 18 120 30 30 30 10 max. 8 18 Ø18 max. Fixed version, front terminals with earth leakage module mounted side by side (1) 250 A 270 150 30 30 30 15 30 30 30 Terminal shields 38.5 53.5 69 215.5 115 1 176 176 38.5 1 115 53.5 69 20 max. 1.6 30 30 30 18 11.5 74 97 52.8 67.8 83.3 97 74 20 max. 30 30 30 30 30 160 A Y 120 30 = = 240 120 Rotary handle-direct on DPX 60 30 M4 8 74 48 35 X 60 A 115 76.5 237 107.7 267 298 62.7 62.7 91.5 M 4 M 4 30 30 30 20 max. 10 max. 18 1.6 74 97 11.5 8 74 97 11.5 M 4 DPX 250 ER 296 A DPX 250 ER + earth leakage module 418 95 176 15 75.5 80 15 Y 135 30 Rotary handle-vari-depth on door Mounting flexible seal 5 70 M4 8 74 358.5 max. 141.5 min. (2) 0.8/2 115 115 38.5 11.25 1.5 max 62.5 (1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage modules (2) 75 mm without mechanical system 21

DPX TM 250 Dimensions Fixed version, front terminals 105 140 100 70 35 17.5 17 36 105 4 min. Draw-out version, front terminals 187 34.5 32.5 34 5 140 (4P) 105 (3P) 20 52.35 34 200 173.5 170 M5 11 10 155 99.5 66.5 90 X 144.75 124.5 192.75 25 35 35 52.5 35 35 35 27 138.5 24.75 353.5 313 449.5 Fixed version with earth leakage module mounted underneath (1) Ø9 140 24 52.5 Front terminals 138.5 105 11 36 Rear terminals 138.5 105 4 min. 34 35 35 35 Y 100 10 Draw-out version, rear terminals 308 278 281.5 47.5 35 35 35 35 35 M12 M12 93.5 93.5 47.5 81 26 Ø9 35 35 19 37 10 81 35 35 35 19 Ø9 26 37 10 10.5 187 34 34.5 187 34 34 35 70 17.5 M5 27 173.5 108.75 90 66.5 99.5 155 24.75 173.5 108.75 90 66.5 99.5 155 24.75 Plug-in version, front terminals 105 140 186.5 20 32.5 33 4 4 min. Rotary handle-direct on DPX 100 50 25 40 58 2.5 maxi. Terminal shields A DPX 250 330 341.5 2.5 200 90 66.5 A DPX 250 + earth leakage module 438 Ø9 35 35 35 35 35 Plug-in version, rear terminals 105 100 140 35 153 186.5 153 4 min. Rotary handle-vari-depth on door Mounting with flexible seal 132 18.5 105 348 max. 0.8/2 131 min. (2) 200 173.5 173.5 90 66.5 62.5 35 35 52.5 35 35 35 153 (1) Dimensions of 3-pole earth leakage modules are the same as 4-pole earth leakage modules (2) 75 mm without mechanical system 22

DPX TM 630 Dimensions Draw-out version, front terminals Fixed version, front terminals 140 183 32 70 32 70 17 50 144 105 4 min. 5 130 183.5 34 34 29 34 100 100 220 260 15 max. 15 max. 265 302 398 265 130 155 X 43.5 43.5 43.5 43.5 87 M5 43.5 43.5 27 43.5 43.5 43.5 Y 14 187 24.7 Fixed version with earth leakage module mounted underneath Front terminals Rear terminals 183 144 70 105 4 min. 144 32 21.75 17 50 105 4 min. Draw-out version, rear terminals Rear terminal with threaded rod.5 34 34 43.5 43.5 43.5 100 220 130 155 103 58 M 16 412 372 372 187 24.7 Flat rear terminal 87 Ø6 or M5 43.5 43.5 43.5 27.5 34 34 43.5 43.5 8 Plug-in version, front terminals 220 130 155 124 29 15 140 183 153 32 70 29 187 24.7 59 398 100 100 302 220 130 X Rotary handle-direct on DPX 100 50 40 58 Terminal shields A DPX 630 390 4 min. 47 A DPX 630 + earth leakage module 542 Ø14 43.5 43.5 43.5 43.5 43.5 192 2.5 max. Plug-in version, rear terminals 140 183 70 100 100 192 153 Rotary handle-vari-depth handle on door Mounting with flexible seal 132 18.5 105 348 max. 0.8/2 131 min. (1) 265 220 130 X 62.5 4 min. (1) 75 mm without mechanical system 23

DPX TM 1250 - DPX TM 1600 Dimensions Fixed version, front terminals Y 210 70 70 25 70 Y 280 70 70 215 29 8 13 min. X 100 149 280 320 70 M10 50 Y Fixed version, rear terminals Draw-out version, rear terminals Terminal shields 480 169 158 298 278 20 25 max. X M12 140 35 M8 5 140 Y 280 (4P) Vertical Horizontal 210 (3P) 105 13 32 23 140 12.5 163 98 140 12.5 90 40 12 X 100 169 320 273 1.5 118 68 M8 273 1.5 56 X 40 14 13 32 3 238 6 2.5 max. 188 3 238 6 2.5 max. 299 256 364 325 34.5 253 218.5 325 360 70 70 70 70 70 Rotary handle-direct on DPX 125 62.5 49 67.5 Rotary handle-vari-depth handle on door Mounting with flexible seal 132 27 140 359.5 max. 0.8/2 142.5 min. (1) 125 66.5 62.5 2.5 max. (1) 75 mm without mechanical system 24

DPX TM MCCBs electrical characteristics DEVICES DPX 125 DPX 160 DPX 250 ER Type of MCCB DPX-E DPX DPX DPX DPX DPX DPX DPX DPX 16 ka 25 ka 36 ka 25 ka 36 ka 50 ka 25 ka 36 ka 50 ka Number of poles 1P 3P - 3P + N/2-4P 3P - 3P + N/2-4P 3P - 3P + N/2-4P Nominal rating (A) 16-125 16-125 63-160 63-160 40-160 100-250 Breaking capacity (ka) (EN 607-2 and IEC 607-2) 400 V± - 16 25 36 25 36 50 25 36 50 230 V± 16 22 35 40 40 50 65 40 50 65 Breaking capacity Ics (% Icu) 50 100 50 75 100 75 50 100 75 50 Characteristics of use Nominal frequency 50/60 Hz Maximum rated operating voltage Ue (V) 230 V± 500 V± - 250 V= 500 V± - 250 V= 500 VV± - 250 V= Category of use A A A Thermal-magnetic adjustment Thermal 0.7 to 1 In 0.64 to 1 In 0.64 to 1 In Magnetic fixed fixed fixed Electronic protection adjustment S1 - - - - - - - - - S2 - - - Maximum cable cross-section Rigid cable 70 mm 2 95 mm 2 185 mm 2 Flexible cable 50 mm 2 70 mm 2 150 mm 2 Copper bar and lug width 12 mm (1) 18 mm (1) 22 mm (1) Tightening torque 6 Nm 10 Nm 10 Nm Nominal current (In) at 40 C (A) In (A) 16 25 40 63 100 125 40 63 100 160 100 160 250 Phase 16 25 40 63 100 125 40 63 100 160 100 160 250 N 16 25 40 63 100 125 40 63 100 160 100 160 250 N/2 - - - - - 63 - - - 100 - - 160 Magnetic threshold (Im) (A) (2) Fixed In (A) 16 25 40 63 100 125 40 63 100 160 100 160 250 Phase 480 625 800 950 1250 1250 400 630 1000 1600 1000 1600 2500 N 480 625 800 950 1250 1250 400 630 1000 1600 1000 1600 2500 N/2 950 1000 1600 (1) Copper bar only (2) Trip current for 50/60 Hz. For direct current, multiply by 1.5 25

DEVICES Type of MCCB Number of poles DPX 36 ka DPX 250 DPX-H 70 ka 3P - 3P + N/2-4P DPX 250 DPX 630 DPX 630 DPX 1250 DPX 1600 Electronic trip Electronic trip Electronic trip DPX 36 ka 3P - 4P DPX-H 70 ka DPX 36 ka 3P - 4P DPX-H 70 ka DPX 36 ka DPX-H 70 ka 3P - 3P + N/2-4P DPX 36 ka 3P - 4P DPX-H 70 ka DPX DPX-H 50 ka 70 ka 3P - 4P Nominal rating (A) 40-250 40-250 250-630 320-630 250-630 400-630 800-1250 800-1600 Breaking capacity (ka) (EN 607-2 and IEC 607-2) 400 V ± 36 70 36 70 36 70 36 70 50 70 50 70 230 V ± 60 100 60 100 60 100 60 100 80 100 80 100 Breaking capacity Bre Ics (% Icu) 100 75 100 75 100 75 100 75 100 75 100 75 Characteristics of use Nominal frequency Maximum rated operating voltage Ue (V) Category of use Thermal-magnetic adjustment Thermal Magnetic Electronic protection adjustment S1 50/60 Hz 690 V± - 250 V= 690 V± 690 VV± - 250 V= 690 V± 690 V± - 250 V= 690 V± A A A A: In 630 A A B B: In 200 to 400 A 0.64 to 1 In - 0.8 to 1 In - 0.8 to 1 In - 3.5 to 10 In - 5 to 10 In - 5 to 10 In - - Ir: 0.4 to 1 In - Ir: 0.4 to 1 In - Ir: 0.4 to 1 In - Im: 1.5 / 10 Ir - Im: 1.5 / 10 Ir - Im: 1.5 / 10 Ir S2 Maximum cable cross-section Rigid cable Flexible cable Copper bar and lug width Tightening torque Nominal current at 40 C (A) In (A) Phase N N/2 Magnetic threshold (Im) (A) (2) In (A) Phase N N/2 - Ir: 0.4 to 1 In - Ir: 0.4 to 1 In - Ir: 0.4 to 1 In Tr: 5 to 30 s Tr: 5 to 30 s Tr: 5 to 30 s - Im: 1.5 / 10 Ir - Im: 1.5 / 10 Ir - Im: 1.5 / 10 In Tm: 0.01 to 0.3 s Tm: 0.01 to 0.3 s Tm: 0.01 to 0.3 s 185 mm 2 185 mm 2 300 mm 2 or 2 x 240 mm 2 300 mm 2 or 2 x 240 mm 2 2 or 4 x 240 mm 2 2 or 4 x 240 mm 2 150 mm 2 150 mm 2 240 mm 2 or 2 x 185 mm 2 240 mm 2 or 2 x 185 mm 2 2 or 4 x 185 mm 2 2 or 4 x 185 mm 2 25 mm 25 mm 32 mm 32 mm 50 mm 50 mm 15 Nm 15 Nm 15 Nm 15 Nm 20 Nm 20 Nm 40 63 100 160 250 40 100 160 250 250 320 400 500 630 250 400 630 800 1000 1250 800 1250 1600 40 63 100 160 250 40 100 160 250 250 320 400 500 630 250 400 630 800 1000 1250 800 1250 1600 40 63 100 160 250 0-50 - 100 % of phase value 320 400 500 630 0-50 - 100 % of phase value 800 1000 1250 0-50 - 100 % of phase value 40 63 63 100 160 250 250 250 320 500 500 630 Adjustable 63 100 160 250 250 400 630 800 1000 1250 220-350 - 560-900 - 1250-2000 - 3150-4000 - 5000-6250 - 630 1000 1600 2500 2500 4000 6300 8000 10000 12500 220-350 - 560-900 - 1250-2000 - 3150-4000 - 5000-6250 - 630 1000 1600 2500 2500 4000 6300 8000 10000 12500 220-220 - 350-560 - 800-1250 - 2000-630 630 1000 1600 1600 2500 4000 (1) Copper bar only (2) Trip current for 50/60 Hz. For direct current, multiply by 1.5 26

DPX TM reading DPX characteristic curves and adjustment ranges Tripping curve for a DPX thermal-magnetic trip 10 000 Tripping curve for a DPX electronic release S2, adjustable Ir, Im, Tr and Tm 10 000 t (s) 1 000 Thermal realease zone when cold t (s) 1 000 Tr = 30 s 20 % Tr = 20 s 20 % Tr = 10 s 20 % 100 100 10 Tr = 5 s 20 % Isf = 250 A Isf = 160 A Isf = 630 A Isf = 1600 A Isf = 400 A Isf = 1250 A 10 Thermal realease zone when hot 1 I 2 t = K Im Isf = 100 A Isf = 40 A Isf = 160 A Isf = 630 A Isf = 250 A Isf = 800 A 1 Adjustable magnetic realease zone 0.1 Tm 0.1 Im 0.01 0.01 0.001 1 2 3 4 5 10 20 30 50 100 I/Ir I: actual current Ir: thermal protection against overloads (setting: Ir = x In) Im: magnetic protection against short-circuits (setting: Im = x In or Im = x Ir) As the abscissa of the curves represents the ratio I/Ir, modifying the setting of Ir will not change the graphical representation of the thermal trip. However, the magnetic setting can be read directly (between 3.5 and 10 in the example). 0.001 0.2 1 2 3 4 5 10 10 20 304050 10 20 30 10 20 30 I/Ir I/In I/In I/In I: actual current Ir: long delay protection against overloads (setting: Ir = x In) Tr: long delay protection operation time (fixed value: 5 to 30 s) Im: short delay protection against short-circuits (setting: Im = x Ir, between 1.5 and 10 Ir in the example) Tm: short delay protection operation time (setting: 0 to 0.3 s) I 2 t constant (adjustable via Tm) If: fixed threshold instantaneous protection (4 to 20 ka depending on model) Adjustment for thermal-magnetic DPX Tripping curve for a DPX electronic release S1, adjustable Ir and Im 10 000 t (s) 1 000 DPX 160 Setting DPX 125 DPX 250 ER DPX 250 DPX 630 DPX 1250 Ir overload trip threshold 0.7 to 1 In 0.64 to 1 In 0.64 to 1 In 0.8 to 1 In 0.8 to 1 In (thermal) Im short-circuit fixed: 10 In trip threshold (100 and fixed: 10 In 3.5 to 10 In 5 to 10 In 5 to 10 In (magnetic) 125 rating) 100 10 Tr = 5 s 1 Isf = 40 A Isf = 250 A Isf = 630 A Isf = 160 A Isf = 1600 A Isf = 630 A Adjustment for DPX electronic release 0.1 Im Isf = 160 A Isf = 100 A Isf = 400 A Isf = 250 A Isf = 1250 A Isf = 800 A Setting DPX 250 / 630 / 1600 S1 DPX 250 / 630 / 1600 S2 0.01 0.001 0.2 1 2 3 4 56 10 10 20 30 40 50 70 10 20 30 10 20 I/Ir I/In I/In I/In I: actual current Ir: long delay protection against overloads (setting: Ir = x In) Tr: long delay protection operation time (fixed value: 5 s at 6 Ir) Im: short delay protection against short-circuits (setting: Im = x Ir, between 1.5 and 10 Ir in the example) Tm: short delay protection operation time (fixed value: 0.1 s) If: fixed threshold instantaneous protection (4 to 20 ka depending on model) Ir overload trip threshold (long delay) Tr long delay trip time Im short-circuit trip threshold (short delay) Tm Short delay trip time 0.4-0.5-0.6-0.7-0.8-0.9-0.95-1) x In fixed: 5 s (to 6 Ir) 5-10 - 20-30 s (to 6 Ir) (1.5-2 - 3-4 - 5-6 - 8-10) x Ir (1) fixed: 0.05 s 0-0.1-0.2-0.3 s (1) 7.9 Ir for DPX 630 In 630 A 27