Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Similar documents
HYDRO Instruction Manual for Model. Hydraulic Generator. Setting the Standard in Mobile Power

HYDRO 600E 10cc. Hydraulic Generator INSTRUCTION MANUAL FOR MODEL. Setting the Standard in Mobile Power

HYDRO 300C-6 Hydraulic Generator

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

Setting the Standard in Mobile Power HYDRO 500-CD-16. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

HYDRO - 200CX HZ

HYDRO 800KEP 11-3 Hydraulic Generator

HYDRO 12KCD 16-3 Hydraulic Generator

Instruction Manual for Model HYDRO 12-KP 11-3 PHASE GENERATOR. Hydraulic Generator. Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

SGB12000HX PORTABLE GENERATOR

Manufacturing of: Vehicle Mounted Generators Hydraulic Generators

AHFP-im-issue INSTRUCTION MANUAL HIGH FLOW DIESEL PUMP AHFP70LPM (70LPM) AHFP100LPM (100LPM) AHFP150LPM (150LPM) AHFP70LPM AHFP100LPM AHFP150LPM

PANCAKE CAPACITOR GENERATOR Installation, Operation and Maintenance Manual

Principals of Operation... 1 Rotary Vane Priming Pump VPE and VPES... 2 Rotary Vane Priming Pump VPO and VPOS Priming Valve...


Designed for Light to Medium Industrial Repair

Commercial generator set Hydraulic Series HG 25000

2015 EDITION SUBMERSIBLE MOTORS AIM MANUAL. APPLICATION INSTALLATION MAINTENANCE 60 Hz, Single-Phase and Three-Phase Motors. franklinwater.

PM300E Voltage Regulator Instruction Manual

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

RigMaster Power Service and Repair Manual Document # S901009

PRO6.4, PRO6.4E, PRO9.0, PRO9.0E Generator Service Manual

ALTERNATOR - CHRYSLER 40/90-AMP & 50/120 AMP

WARNING This manual should only be used by a qualified Service Technician. FinishPro 390/395 Airless/Air-Assisted Sprayer Repair Electrical Manual

Machine Component Identification Items: , ,

FIRE-POWER 12 & 14 KW SELF-CONTAINED HYDRAULICALLY DRIVEN ELECTRIC POWER GENERATOR SYSTEM

3000W POWER INVERTER. User Manual

Model 5-025, 5-050, &

Unit 32 Three-Phase Alternators

CHARGING SYSTEM 8C - 1 CHARGING SYSTEM CONTENTS

OutdoorXUPS-600AHV-8364

CONTENTS. Product Features and Specifications Installation Requirement Steps of Installation 4. Exploded View Test Run...

INSTRUCTION MANUAL ELECTRIC DIESEL PUMP KIT

Operation Manual Model: PPSSS Submersible Slurry Pump

Type C Track Circuit Uninterruptable Power Supply

GEN 5.0 Generator Service Manual

D-Series Blowers and Exhausters

NIGHT-LITE PRO II. Electrical System Troubleshooting Guide and Procedures

WELDING FUME EXHAUSTERS & ARMS

Heavy duty slurry pumps

INDUSTRIAL GENERATOR SERVICE

Model: PI-140 Power Inverter Converts 12V DC battery power to 120V AC household power

Electrical Equipment and Terminology

User s Manual D-Series Blowers and Exhausters

C627, C628, C631, C656, C657, C658, C671 and C680 Alternator Troubleshooting Guide

Hydrostatic Drive. 1. Main Pump. Hydrostatic Drive

This chapter contains information on DC Generation, External Power, and Electrical Load Distribution.

ALTERNATOR - BOSCH 35/75-AMP & 40/90-AMP

Starting up hydraulic systems

POWER MODULE MTU 16V4000 DS2560

Portable Oil Free Silent Series Compressor Operating Instructions

Power-Tronics, Inc. Electronic Voltage Regulators and Static Exciters P.O. Box , Kerrville, Texas 78029

Equipment Coll-O-Crimp Pumps

Operation & Service Manual

FAULT FINDING MANUAL. For Stamford AC Generators

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

6L Oil-less Air Compressor 53103

Troubleshooting 3Z8 038 Rev B

Installation & Operating Manual

Dimensions 12/800N 12/1200N D. DC to AC Power Inverters. OWNERS MANUAL for Models: OWNERS MANUAL April ISO 9001:2000 Certified Company

Technical Information for PVX Series Pumps

V 2.0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W. Instruction Manual

ADI-125/750 ADI-125/1500 ADI-125/2500

AHFP85L-im -issue INSTRUCTION MANUAL 12V HIGH FLOW DIESEL PUMP KIT AHFP85L-12A

MOBILE FIRE - RESCUE DEPARTMENT FIRE CODE ADMINISTRATION

XCITE Owner s Manual. Reso-not TM Damping System XCITE 1502C HYDRAULIC POWER SUPPLY

3 Phase Smart Controller

Automatic taper of charge rate for superior battery life through good equalization of cells and low water use rate.

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

600 Series Troubleshooting Guide for C651 and C654 Alternators

XR500B Universal Voltage Regulator

TA-05/C. Instruction and Operation Manual. valid for art.-no.: F-TA-05/C-ISO. (start at modification No. 1601)

BULLETIN BAQSOLO AQUAVAR SOLO CONSTANT PRESSURE CONTROLLERS FOR: 1Ø 3-WIRE MOTORS, 1Ø 2-WIRE CENTRIPRO MOTORS, 3Ø MOTORS

Pretest Module 21 Units 1-3 AC Generators & Three-Phase Motors

OWNER S MANUAL POWER INVERTER

Artesis MCM Case Studies. March 2011

USER S MANUAL FOR F & Q. Submersible Sewage Pumps

AFM500X Automatic Flashing Module

Caution: This document contains mixed page sizes (8.5 x 11 or 11 x 17), which may affect printing. Please adjust your printer settings according to

Centro América Application of EMI Diagnostics to Diesel Generators

SPECIFICATIONS FOR GASOLINE DRIVEN ENGINE ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B1000 M-G

JCB DIESEL GENERATOR TECHNICAL SPECIFICATIONS

ATD WATT INVERTER

Electric Vehicle Supply Equipment EVSE Vehicle Simulator

PM500. Voltage Regulator User Manual. A Regal Brand. Scan here for other languages.

VAC Electrical Requirements. VDC Electrical Requirements

HYDROMATIC HE8/HE12/HE20/HE25/ HE30/HE35/HE50 HIGH HEAD FILTERED EFFLUENT

RENTAL DIESEL GENERATOR SET

PT, PTS & PTP Series Pump/Reservoirs

Copeland Screw Compressors Semi-Hermetic Compact Operating Instructions

SERVICE MANUAL DGK25E DGK25EU

Home About Us Products & Services Search Contact Us

MODEL 25-OM-10-C & 25-OA-10-C HYDRAULIC BOOSTER

Pyrolance, LLC SPECIFICATIONS FOR DIESEL ENGINE DRIVEN ULTRA HIGH PRESSURE FIRE FIGHTING SYSTEM B2000 M-D

ROGERS MACHINERY COMPANY, INC

XENON POWER SUPPLY 4000 Watt Gladiator IV

TABLE OF CONTENTS. 1. Before You Begin 3 Disclaimer 3 What Is Included 3 Optional Accessories 3 Unpacking Instructions 3 Claims 3 Contact Us 3

Charging Systems. ATASA 5 th. ATASA 5 TH Study Guide Chapter 19 Pages Charging Systems 42 Points. Please Read The Summary

ELECTRICAL SYSTEM RP-7

Transcription:

Setting the Standard in Mobile Power for Model HYDRO 350 SJ Hydraulic Generator Manufacturing of: Vehicle Mounted Generators Hydraulic Generators P.O. Box 582 Chester, NY 10918 845-469-9151 Fax: 845-469-7871 Web Site/E-mail: www.fabcopower.com

GENERAL INFORMATION MODEL: HYDRO 350 - SJ GENERATOR... BRUSHLESS GENERATOR... 3600 (60 Hz) GENERATOR VOLTAGE... 120 or 120/240 MOTOR STARTING... 300% SURGE VOLTAGE REGULATOR... INHERENT OUTPUT... 3500 WATTS CONTINUOUS 4000 WATTS PEAK AT 100 F OIL TEMPERATURE HYDRAULIC MOTOR... GEAR TYPE MAXIMUM SPEED... 4200RPM (3600 RPM IDEAL) MOTOR SHAFT... ½ inch PORT SIZE INLET... S.A.E.-8 RETURN... S.A.E.-10 CASE DRAIN PORT..S.A.E.-4 Page 2

RECOMMENDATIONS MODEL: HYDRO 350- SJ HIGH PRESSURE LINE... ½ inch LOW PRESSURE LINE... ¾ inch FLOW RATE... 7.5 GPM IDEAL FOR BEST RESULTS KEEP HYDRAULIC OIL TEMPERATURE BETWEEN 80 F AND 120 F. DO NOT EXCEED 175 F. AN OIL COOLER IS RECOMMENDED. MAXIMUM BACK PRESSURE... 150 PSI WILL OPERATE ON ANY 2500 PSI OPEN CIRCUIT OR CLOSED LOOP SYSTEMS. RECOMMEND FILTER... 10m RECOMMEND HYDRAULIC OIL... DEXTRON III A.T.F. INSTALLATION TIPS Excessive pressure in your return line will damage the hydraulic motor seal. High back pressure can be caused by spikes sent back through the return from other equipment on a common return line. Another potential problem can develop if several pieces of equipment are connected to one common return line causing a high back pressure (150 PSI is the maximum). We recommend you run the return line from the generator back to the cooling tank with a separate line. You can either run the 3/4 inch return line back to the tank or leave the 3/4 inch line connected to a common return and run a separate 3/8 inch line from the case drain (located at the bottom of the hydraulic motor) directly back to the tank. Either way you completely eliminate any problem of excessive return line pressure damaging your hydraulic motor. Page 3

Initial Installation and Start-Up Be sure you set the hydraulic flow (GPM) to the generator at Approximately 62.5 HZ or 3750 RPM with NO electrical load on the generator. By using this setting you will have approximately 60HZ (cycles) or 3600 RPM when you are running at full rated load. One way this can be accomplished is by using a Photo Tachometer on our generator coupling or generator cooling fan. A Photo Tachometer is an inexpensive tool that can be purchased at McMasters, Grainger, Sears or any other electrical supplier. Page 4

TECHNICAL INFORMATION These self-excited and self-regulating generators, although overall dimensions have been reduced to a minimum, are designed for high-level electrical performance and the maximum in operating reliability. PRELIMINARY CHECKS: STARTING UP: THE IMPORTANCE OF SPEED: CHECKING VOLTAGE: CHECKING THE DIODES: Before touching the machines, perform a thorough and in depth visual inspection, checking that components are correctly connected up and that no cables or terminals are broken or loose. Make sure, when starting up, that cooling air intake and discharge openings are free and unblocked. We also recommend (when the machine operates in a dusty environment) do periodic checks to make sure it is properly ventilated Frequency and voltage depend directly on rotation speed. This must be kept as constantly as possible on its nominal value no matter what the load. Drive motor speed control systems generally have a small drop in speed between no load and loaded conditions. We therefore recommend setting no load speed 3 4% above nominal speed. All the machines are regulated during factory testing. If voltage readings differ from the value indicated on the name plate, this maybe caused by a mistaken reading or by a different rotation speed and we recommend regulating motor speed in order to have nominal RPM under loaded conditions. For the ohmmeter test it is best to disconnect the diode from its circuit. Measure continuity in one direction only. The test can also be made without disconnecting the diode form the circuit, using a 12V battery and a 45 watt light bulb (automobile light) as shown in the illustration. The light should turn totally on only in one direction, as shown below. WINDING RESISTANCE AT 20 C ROOM TEMPERATURE Size Stator Ω Rotor Ω Exciter Ω 3.5 0.7 9.22 4.0 4.0 0.7 9.28 4.0 5.0 0.54 2.97 2.24 6.0 0.54 2.97 2.24 8.0 0.49 2.85 4.41 12.0 0.250 5.65 0.60 Page 5

ELECTRICAL CONNECTIONS CONNECT NEUTRAL TO GROUND IF USING GFCI OUTLETS NEUTRAL (WHITE) U2 V2 120/240 VOLT OPERATION 120 120 V1 W1 RED OR BLACK WIRE 240 25 AMP OVERLOAD SELF RE-SETTING GROUND SCREW ON GENERATOR FRAME. USE GREEN WIRE FOR GROUND IF USING GFCI OUTLETS TERMINAL BLOCK RED OR BLACK WIRE JUMPER (BLACK) 30 AMP OVERLOAD SELF RE-SETTING U2 V2 NEUTRAL (WHITE) HOT LEAD (BLACK) V1 120 W1 120 VOLT FULL POWER OPERATION GROUND SCREW ON GENERATOR FRAME. USE GREEN WIRE FOR GROUND IF USING GFCI OUTLETS TERMINAL BLOCK Page 6

PARTS BREAKDOWN HYDRO 350 - SJ No. PART # DESCRIPTION 1 572262 Louvered Panel 2 572264 Frame For Stator 3 572182 Drive End Bell 3 a 572265 Screen 4 572235 Front Bearing 5 572184 Fan 6 572266 Rotor 8 572064 Rear Bearing 13 572186 User Terminal Board 15 572260 Cover 17 572288 Capacitor 31.5 mfd/w Tie Wraps 19 572189 Diodes 20 572615 Pump Mount 21-23 Discontinued 24 572579 Hydraulic Motor 25 572128 Rails 26 572154 Mounts 28 572261 Stud Cover PART # OPTIONAL CONTROL PANEL 29 572263 Rubber Cup 572227 Complete Control Panel 30 572272 Fan Ring 572228 Control Box (Shell) 572072 Seal For Hydraulic Motor 572052 Volt Meter 572274 Generator Complete 572054 Receptacle 120 Volt 572159 Voltage Indicating Light 572100 Waterproof Recpt. Cover 572158 Overload Protection Device 572226 GFI Outlet 120 Volt Page 7

TROUBLE SHOOTING PROBLEMS CAUSES REMEDIES ALTERNATOR EXCITATION FAILURE 1. Low Speed 2. Faulty capacitor 3. Faulty winding 1. Check RPM and set at nominal value. 2. Check and replace. 3. Check that winding resistance is as shown in the tables. HIGH NO-LOAD VOLTAGE LOW NO-LOAD VOLTAGE PROPER NO-LOAD BUT LOW LOADED VOLTAGE UNSTABLE VOLTAGE NOISY GENERATOR 1. Speed too high. 2. Capacitor with high capacity. 1. Speed too low. 2. Faulty rotary diodes. 3. Breakdown in windings. 4. Capacitor with high capacity. 1. Low loaded speed. 2. Load too large. 3. Rotary diodes short-circuited 1. Loose contacts. 2. Uneven rotation. 1. Broken bearings. 2. Poor couplings. 1. Check and adjust RPM s 2. Check and replace 1. Check and adjust RPM s 2. Check and replace. 3. Check winding resistance, as per tables. 4. Check and replace. 1. Check and regulate RPM. 2. Check and change. 3. Check and replace. 1. Check connections. 2. Check for uniform rotation speed. 1. Replace. 2. Check and repair. Page 8

FIXED DISPLACEMENT TYPE GEAR PUMP 5 6 4 3 7 2 1 TYPICAL HYDRAULIC SCHEMATIC 8 1. HYDRAULIC PUMP 2. PRESSURE RELIEF VALVE 3. CONTROL VALVE 4. PRIORITY FLOW CONTROL* 5. GENERATOR HYRAULIC MOTOR 6. CASE DRAIN LINE** 9 7. RETURN LINE FILTER 8. OIL COOLER 9. HYDRAULIC FLUID RESERVOIR * Some units may be equipped with integral priority flow control, refer to specific model number. ** External case drain line may be required on some units refer to specific model number. When external case drain is required it should be unobstructed direct return to reservoir with a minimum I.D. no less than that of case drain port on generator motor. FOR SPECIFIC INSTALLATION RECOMMENDATIONS CONSULT FACTORY Page 9