Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

Similar documents
w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Installation and Operation Back-UPS BX550CI-CN

Installation and Operation Manual Back-UPS BR800/1100CI-IN

BSNL POWER PLANT MANAGEMENT SYSTEM USING VOICE ALONG WITH TELEPHONE LINE

Installation and Operation Manual Back-UPS BX1100CI-CN

3000VA 120/208/230VAC

Installation and Operation Manual Back-UPS BR1000-CH

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

General Precautions. Personnel Precautions

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Back-UPS CS Back-UPS CS 350

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

OutdoorXUPS-600AHV-8364

DC AC POWER INVERTER. LIV 10 / LIV 20 / LIV 30 User Manual

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

Users Manual. Cobra Plus Stand-By Emergency Lighting Inverter. Technical Manual # Revision B

User Manual Digital Energy Uninterruptible Power Supply ML Series UPS VA GE Digital Energy Power Quality

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

Uninterruptible Power System

800VA/ 1000VA/ 1200VA/ 1500VA 2200VA/ 3000VA USER S MANUAL

Users Manual. Defender 1 8.0KW to 14.0KW Online Emergency Lighting Inverter. Technical Manual # Revision B

GP-1000 Inverter. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4 Tel: Fax:

User Manual. Digital Energy Uninterruptible Power Supply ML Series UPS VA. GE Digital Energy Power Quality. GE imagination at work

BRAVO Inverter/Battery Charger. Table of Contents

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Go Power! Manual. GP-1750HD Inverter GP-2500 Inverter

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION INVERTER OPERATION...

Uninterruptible Power Supply

MM-AVR UPS Series User s Manual

APC Smart-UPS RT UXI/UXICH

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

POWER TROLLEY 8 INSTRUCTION MANUAL POWER TROLLEY 8. Model: SINE Instruction Manual for: Self-Contained Sinewave Mobile Power Backup System

Sola 3000 Guide Specifications

Pure Sine Wave Inverter GP-HS1500. Owner s Manual

Phoenix Inverter

USER MANUAL ONLINE UPS 6000L(XL)/10000L(XL) Uninterruptible Power Supply

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

USER MANUAL. Power GUARD UPS. Uninterruptible Power System

USER MANUAL. Blazer Vista 1000/1400/2000. Uninterruptible Power System

BRAVER UPS. (Uninterruptible Power System) User s Manual

USER MANUAL. IPS home inverters with UPS function. IPS home inverter manual

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

Uninterruptible Power System

Limousin II User Manual

BroadBand PowerShield. 20 AHr Battery. User Manual

c-go 12V/10A 12V/20A Power supply and battery charger Instruction manual

MODEL A96 SERIES. 130Vdc Switchmode Utility Rectifier / Battery Charger. Used with LaMarche Power Cage ECN/DATE

USER MANUAL MPS 1-5KW SERIES

Home Solar 400 (HS 400) Home Solar 800 (HS 800) Home Backup 400 (HB 400) Home Backup 800 (HB 800) Owner s Manual

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Go Power! Manual. GP-SW1500 Inverter. Table of Contents. Go Power! Electric Inc. PO Box 6033 Victoria, BC V8P 5L4

LINE INTERACTIVE LONG BACKUP TIME UPS EN-1000 / EN-2000 USER S MANUAL

CONTENTS 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION SYSTEM DESCRIPTION OPERATION... 9

Installation Operation Parts

400 Watt Backup Power System Owner s Manual

Uninterruptible Power System

Match 19" GE Digital Energy. Uninterruptible Power Supply VA. Technology for the Digital World. Match 19" UPS.

Installation, Maintenance and Warranty Flat Plate Battery

Allen-Bradley. User Manual for 8000/10000 VA UPS. Tower/Rack-Mount 6U Uninterruptible Power Supply

Illuminator Series CM. GUIDE SPECIFICATIONS And TECHNICAL DESCRIPTION. 500W, 1000W, 1500W and 2000W Single-Phase Emergency Power System

USER S MANUAL ENDURE 500VA ENDURE 750VA ENDURE 1000VA ENDURE 2000VA

PROwatt 150 DC to AC Power Inverter. Owner s Guide

Installation and Operations Manual

DC TO AC POWER INVERTER PWRIC150012W INSTRUCTION MANUAL

Outdoor UPS. User Manual. Contents. Please read carefully this manual before installing and using this product. 1 Introduction Safety...

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

CP900EPFCLCD User s Manual K

Broadband PowerShield. CP27U Models. User Manual

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

SCC-MPPT Solar Charge Controller

User Manual. Smart-UPS. Uninterruptible Power Supply 750/1000 VA. 100/120/230 Vac. Rack Mount 1U

User Manual 1.5KVA-3KVA INVERTER / CHARGER. Version: 1.1

On Line UPS. LUC 1000E / LUC 2000E / LUC 3000E User Manual

Operators Manual. Recirculating Chiller /06/08

JUMP STARTER OPERATOR S MANUAL RA1900

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

Item no Smart AC 200 USB. User s Manual

Sola/Hevi-Duty S3K Series Mini-Tower UPS

OWNER S MANUAL AND INSTALLATION INSTRUCTIONS

SOLAR INVERTER/CHARGER 1000VA/1500VA/2000VA. Appliances. PC TV Light Electricfan

User Manual 1KVA-5KVA INVERTER / CHARGER

CTFRP Series Power Supplies

UTILITY INPUT MAINS OUTLET

USER MANUAL. PowerMust 1400/2000 LCD. Uninterruptible Power System

WARNINGS, CAUTIONS AND NOTES

Operation and Maintenance

SCC-MPPT Solar Charge Controller

Matrix APAX. 380V-415V 50Hz TECHNICAL REFERENCE MANUAL

Solar Charge Controller

USER S MANUAL CONTENTS. Uninterruptible Power Supply 1. INTRODUCTION SAFTY INSTRUCTION CABLE CONNECTION... 4

SCC-MPPT Solar Charge Controller

02/15/01. Powerware User s Guide VA.

c-go 24V/6A 24V/8A 24V/12A

Transcription:

w w w.apc.com Power Inverter Model BI800T and BI800F Installation Guide and User s Manual 990-1810A Copyright 2004 American Power Conversion. All rights reserved. APC is a registered trademark of American Power Conversion. All other trademarks are the property of their respective owners.

CONTENTS Page Overview 1 Checklist 1 Section 1. Unpacking/Inspection (at reseller location) 2 Main Housing Chassis and Inverter 2 Battery Inspection 2 Unpack Battery 2 Inspect Battery 2 Clean battery 2 Remove Battery from Shipping Container 2 Check Battery Fluid Level 2 Check Battery Charge Level 3 Repackage Battery 3 Section 2. Unpacking/Inspection (at customer location) 3 Main Housing Chassis and Inverter 3 Battery Inspection 4 Unpack Battery 4 Inspect Battery 4 Clean Battery 4 Remove Battery from Shipping Containe 4 Check Battery Fluid Level 4 Check Battery Charge Level 4 Section 3. Installation 1 Main Housing Placement 4 Location Selection 4 Lock Wheels 4 Battery Installation 4 Main Housing Chassis Rear Panel Removal 4 Install a Battery 5 Battery Connections 6 Install Main Housing Chassis Rear Panel 6 Install Inverter 6 Install Wiring Management Kit 7 Section 4. Controls and Indicators 9 Inverter Controls 9 AWAY/HOME 9 TEST/MUTE 9 Circuit Breaker Switch 9 Inverter Indicators 9 Section 5. Troubleshooting 12 Manual Bypass 12 Preventative Maintenance 13 Specifications 14 Warranty 15 Contact Information 15 i

CONTENTS - continued FIGURES Page Figure 1. APC Power Inverter 1 Figure 2. Battery Elements (tubular battery shown) 2 Figure 3. Battery Fill Cap Elements 3 Figure 4. Main Housing Chassis Rear Panel Removal 5 Figure 5. Battery Installations and Connections 6 Figure 6. Inverter Assembly Placement 7 Figure 7. Typical Home Wiring Before Inverter Installation 7 Figure 8. Typical Home Wiring After Inverter Installation 8 Figure 9. Power Inverter Connections 8 Figure 10. Wiring Management Kit Installation 9 Figure 11. Power Inverter Front Panel Controls and Indicators 10 Figure 12. Power Inverter Bypass Connection 13 TABLES Table 1. Power Inverter Indicators 10 Table 2. Power Inverter Troubleshooting 12 Table 3. APC Power Inverter Technical Specifications 14 ii

Thank you for purchasing APC s Power Inverter. Please fill out the enclosed Warranty Registration Card, or register your purchase on-line at: www.apc.com/support. Overview APC s Power Inverter (Figure 1) is designed for years of trouble-free use. The Inverter is a sinewave back-up power supply intended to serve house loads. It is rated for 800 VA/500W at 230 Vac, 50-Hz, and operates on a wide range of input voltages (100-265V). If the input voltage goes out of range (less than 100V or more than 265V), the utility is isolated and the inverter supplies power to the load from the internal batteries. The Inverter can serve inductive loads (flourescent lamps, ceiling and table fans), resistive loads (incandescent lamps), and switched mode power supply (SMPS) loads (television). The typical backup time with the primary battery pack at full load is approximately two (2) hours. Backup time can be further extended by connecting the optional external battery pack in parallel to the existing battery pack. Checklist: Note: APC offers tubular, as well as flat-plate batteries for use with the Power Inverter. For the purposes of this manual, only the tubular batteries are shown. Depending on what the customer has ordered, ensure the following items have been delivered: Inverter Batteries (2), Tubular Batteries Shown Main Housing Wiring Kit Fill Kit (rubber gloves and a funnel) Wire Management Kit Parallel Wiring Kit (if external battery pack was ordered - not shown) Wire Management Kit (Optional) Inverter Assembly Handles (1 each side) Batteries Main Housing Chassis (Wire Harness Not Shown) Figure 1. APC Power Inverter Page 1

Section 1. Unpacking/Inspection (at reseller location) Main Housing Chassis and Inverter! Inspect the shipping containers for signs of obvious damage. If damage to either shipping container is extensive, notify the carrier and return the unit to the factory. If there are no apparent signs of damage, carefully open the container, and remove the packing materials (do not discard). To remove the Main Housing Chassis or Inverter Assembly from the shipping container, grasp the handles located on each side of the housing or inverter (Figure 1), and remove the item from the container. Inspect each for: dents, scratches, broken or missing wheels (housing only), warpage of the top cover, or other signs of damage. If either unit is damaged, please notify the factory and obtain a Return Material Authorization number and return the unit as/if instructed. If there are no obvious signs of damage, repackage the unit for shipment to the customer using the materials already removed from the shipping container. Ship or otherwise deliver the unit to the customer location. Battery Inspection Warning: The Main Housing Chassis weighs 18 kg. Two-person lift required. Failure to comply may result in personal injury. Unpack Battery - Inspect the battery shipping container for signs of obvious damage. Carefully inspect the container for signs of a leaking battery. If the shipping container shows signs of leakage, the battery may be damaged. Contact the factory for instructions to further inspect the battery inside the container, or for return instructions. Carefully open the shipping container and remove the packing materials (do not discard). Inspect Battery - If there are no obvious signs of damage or leakage, with the battery in the shipping container, inspect the battery for leaks, cracks, broken wiring terminals, broken handles, and broken fill caps (Figure 2). Battery Fill Cap (6) Battery Handle (1 each side) Battery Terminal (2) Figure 2. Battery Elements (tubular battery shown) Clean battery - If the inspection shows signs of a leaking battery, put on rubber gloves and remove the battery fluid/residue from the battery housing using a mixture of baking soda and distilled water. If cracks or other damage is noted after cleaning the battery, contact the factory for return or disposal instructions.! Warning: Each battery weighs 28 kg. Two-person lift required. Failure to comply may result in personal injury. Remove Battery from Shipping Container - Remove the battery from the shipping container by grasping the handles (see Figure 1) located at each end of the battery. Lift the battery straight up and out of the shipping container. Check Battery Fluid Level - After cleaning and inspection for damage, check the battery fluid level of each cell (Figure 3). If the fluid level of any cell is not within the specified range on the fill cap, put on rubber gloves (from Fill Kit), remove the battery cell cap, and fill the cell with distilled water using the funnel provided in the Fill Kit. Install the cell cap on each cell. Page 2

Fluid Level Tube Fluid Level Indicator Optimum Fill Range Battery Fill Cap Float Device Figure 3. Battery Fill Cap Elements Check Battery Charge Level - After filling battery cells (if necessary), check the battery specific gravity using a hydrometer. The battery specific gravity should be between 1230 and 1250. If battery specific gravity is below 1230, charge the battery using a battery charger until the battery specific gravity is within the acceptable range.! Repackage Battery - Place the battery in the shipping container by grasping the handles located at each end of the battery. Lift the battery straight upwards and place it in the shipping container. Install packaging materials. Seal the shipping container, and ship the battery to the customer location. Section 2. Unpacking/Inspection (at customer location) Main Housing Chassis and Inverter Warning: Each battery weighs 28 kg. Two-person lift required. Failure to comply may result in personal injury. Note: The Inverter Assembly is shipped with two (one male and one female) IEC connectors for use in installing home wiring to/from the Inverter. Inspect the shipping containers for signs of obvious damage. If damage to either shipping container is extensive, notify the carrier and return the unit to the factory. If there are no apparent signs of damage to the shipping container, carefully open the container, and remove the packing materials (do not discard).! Warning: The Main Housing weighs 18 kg. Two-person lift required. Failure to comply may result in personal injury. To remove the Main Housing Chassis or Inverter from the shipping container, grasp the handles located on each side of the Housing or Inverter (Figure 1), and remove the item from the shipping container. Inspect each for: dents, scratches, broken or missing wheels (housing only), warpage of the top cover, or other signs of damage. If either unit is damaged, please notify the factory and obtain a Return Material Authorization number and return the unit as/if instructed. If there are no obvious signs of damage, proceed with Battery Inspection. Page 3

Battery Inspection Unpack Battery - Inspect the battery shipping container for signs of obvious damage. Carefully inspect the container for signs of damage due to a leaking battery. If the shipping container shows signs of leakage, the battery may be damaged. Contact the factory for instructions to further inspect the battery inside the container, or for return instructions. Carefully open the shipping container and remove the packing materials (do not discard). Inspect Battery - If there are no obvious signs of damage or leakage, with the battery in the shipping container, inspect the battery for leaks, cracks, broken wiring terminals, broken handles, and broken fill caps (Figure 2). Clean Battery - If the inspection shows signs of a leaking battery, put on rubber gloves and remove the battery fluid from the battery housing using a mixture of baking soda and distilled water. If cracks or other damage is noted after cleaning the battery, contact the factory for return or disposal instructions. Remove Battery from Shipping Container - Remove the battery from the shipping container by grasping the handles (see Figure 2) located at each end of the battery. Lift the battery straight upwards and out of the shipping container. Check Battery Fluid Level - After cleaning and inspection for damage, check the battery fluid level of each cell (Figure 3). If the fluid level of any cell is not within the specified range on the fill cap, put on rubber gloves, remove the fill cap, and fill the cell with distilled water. Install the fill cap on each cell. If battery fluid is discharged from the battery during the filling process, put on rubber gloves and remove the battery fluid from the battery housing using a mixture of baking soda and distilled water. Check Battery Charge Level - Ufter filling battery cells (if necessary), check the battery specific gravity using a hydrometer. The battery specific gravity should be between 1230 and 1250. If battery specific gravity is below 1230, charge the battery using a battery charger until the battery specific gravity is within the acceptable range. Section 3. Installation! Main Housing Placement Note: Once the unit has been completely installed, it is not desireable to move it. Location selection - unlock the wheels located at the bottom of the Main Housing Chassis, and roll it to the desired location. Ensure the area where the unit is to be placed is not in direct sunlight (surfaces may become hot). Further ensure the unit is placed in a dry area away from sources of liquids, and that the vents on each side have at least 15 cm (6 inches) of unobstructed clearance (Figure 4). Lock Wheels - Lock the wheels to restrict movement during battery installation. Battery Installation Warning: Each battery weighs 28 kg. Two-person lift required. Failure to comply may result in personal injury. Main Housing Chassis Rear Panel Removal - Remove the four machine screws (Figure 4) that secure the Rear Panel to the Main Housing Chassis. Remove the Rear Panel and set it aside. Page 4

Main Housing Chassis (Rear View - Wire Harness not Shown) Remove the 4 corner screws only. Air Vents (Each Side) Rear Panel Do Not Remove These Two Screws 15 cm (6 inches) Wheels (4). 15 cm (6 inches) Note: Allow 15 cm (6 inches) of unobstructed clearance on each side.! Figure 4. Main Housing Chassis Rear Panel Removal Note: Access through the top of the Main Housing Chassis is provided for connecting and topping (filling) of the batteries only. Warning: Each battery weighs 28 kg, and must be installed through the opening at the rear of the Main Housing Chassis and not through the opening in the top of the unit. Failure to comply may result in personal injury and/or equipment damage Install a Battery - Raise the top lid of the Main Housing Chassis to provide visual access to the interior of the chassis (Figure 5). Note: The batteries are installed with the long side of the battery going across the length of the front panel. Caution: Installation of the Power Inverter Batteries must be performed by a licensed and qualified electrician. Failure to comply may result in equipment damage, and may also void the Warranty. At the rear of the Main Housing Chassis, position the first battery to be installed through the rear opening so that the positive (+) terminal is to the right. Position the second battery so that the positive (+) terminal is to the left. Grasp the battery using the handles (Figure 2) located at each end of the battery. Carefully lift the battery and slide it into the Main Housing through the rear opening. Slide the first battery as far forward as it will go into the Main Housing Chassis. Repeat this step for the second battery until it is up against the second battery. Page 5

Main Housing Chassis (top cover not shown) Main Housing Chassis (top cover shown) Battery Handle Negative (-) Terminal First Battery Battery Handle Positive (+) Terminal Negative (-) Terminal Red (+) Wire Positive (+) Terminal Black (-) Wire Black Wire Battery Handle Battery Handle Positive (+) Terminal Negative (-) Terminal Second Battery (rotated 180 degrees) Battery Installation Main Housing Chassis (rotated 180 degrees) Battery Connections Figure 5. Battery Installations and Connections Battery Connections - Note: The batteries are charged and produce electric current. Small sparks by be noted during the connection process. This is a normal condition and does not pose a threat of injury. Connect the red battery terminal lead (protrudes from the lid) to the positive (+) terminal of the battery (Figure 5) closest to the rear of the Main Housing Chassis (second battery installed). Connect the black battery terminal lead (protrudes from the lid) to the negative (-) terminal of the first battery installed. Connect the black battery cable attached to the left side of the Main Housing Chassis to the positive (+) terminal of the first battery, and to the negative (-) terminal of the second battery. Ensure battery connections are tight by grasping each connector at the terminal and try to move it. If the terminal lead has movement on the terminal, tighten the connection until no movement is evident. Install battery terminal covers. Install Rear Panel - Align the Rear Panel with the mounting holes at the rear of the Main Housing Chassis. Install the four machine screws which secure the Rear Panel to the chassis. Install Inverter Caution: Installation of the Power Inverter must be performed by a licensed and qualified electrician. Failure to comply may result in equipment damage, and may also void the Warranty. Place the Inverter Assembly on top of the Main Housing Chassis with the Inverter facing forward, and the Inverter feet in the indents provided on the Main Housing Chassis top cover. Page 6

Inverter Assembly ( feet not shown) Indents (4 places) (Wire Harness not Shown) Figure 6. Inverter Assembly Placement Remove power at the electricity board meter (circuit breaker panel) of the home. Figure 7 shows a diagram of a typical home wiring scenario. Figure 8 shows a typical home wiring scenario after installation of the Inverter Assembly wiring. Note: The Power Inverter can serve inductive loads (flourescent lamps, ceiling and table fans), resistive loads (incandescent lamps), and SMPS loads (television). The typical backup time with the primary battery pack at full load is approximately two (2) hours. Caution: Connecting the Power Inverter to a branch circuit that exceeds 16 amps may result in equipment damage. Note: Home wiring to power the desired loads should be routed and connected to a single branch circuit providing a maximum of 16 amps to the circuit, Wiring must be in accordance with local electric codes and standards. Connected loads must not exceed 500 watts when the Inverter is On Battery. Double-Pole Switch L L Electricity Board Meter N E N E Load Existing Wiring Figure 7. Typical Home Wiring Before Inverter Installation Page 7

E E Electricity Board Meter N L N L Load Double-Pole Switch Lighting Circuit Input Output Wiring for Power Inverter Figure 8. Typical Home Wiring After Inverter Installation Connect one end of the electrical cable from the double-pole switch lighting circuit in accordance with local electric codes and standards. Connect the other end of the electrical cable to the provided IEC connector, and then to the rear panel Input connector on the Inverter Assembly (Figures 8 and 9). Connect one end of the electrical cable from the load in accordance with local electric codes and standards. Connect the other end of the electrical cable to the provided IEC connector, and then to the rear panel Output connector on the Inverter Assembly (Figures 8 and 9). Connect the wiring harness (protrudes out of the top of the Main Housing Chassis top cover) from the batteries to the rear panel input connector of the Inverter (Figure 9) marked 24V Battery. Once the home wiring is complete and the batteries are connected to the Inverter Assembly, turn on power at the Electricity Board Meter then at the Double-Pole Switch Lighting Circuit. The Inverter will automatically turn on. 24V Battery Push to Reset N INPUT L L OUTPUT N Input : 230V, 5A, 50Hz Output : 230V, 5A, 50HZ Battery Wiring Output Harness (Red and Black Wires from Main Housing Chassis - Top) These connectors are provided with the Inverter Assembly and must be installed on to the wiring. From Electricity Board Meter (through Double-Pole Switch Lighting Circuit) To Load Figure 9. Power Inverter Connections Page 8

Install Wiring Management Kit Installation of the Wiring Management Kit consists of unpacking and inspecting the kit for signs of obvious damage, and return or replace as necessary, and placement of the unit on the Main Housing Chassis. Secure the kit to the chassis by placing the alignment pins (Figure 10) with the holes provided in the top of the Main Housing Chassis, and pushing straight downward until all four retaining pins are fully seated. Wiring Management Kit Holes (4 places) Alignment Pins (4 places) Figure 10. Wiring Management Kit Installation Section 4. Controls and Indicators Please review this section thoroughly before applying power to the Power Inverter. Inverter Controls - Controls provided on the Power Inverter consist of the holiday mode switch marked AWAY/HOME, and the Test/Mute switch, as well as a rear panel Push to Reset circuit breaker, and are defined in the following: AWAY/HOME - (also known as the holiday mode switch) - In the HOME position, this two-position rocker switch (Figure 11) sets the Inverter so that it will switch to battery output when there is a utility power outage. In the AWAY position, the Inverter goes into standby mode and will not switch to battery power in the event of a power outtage. This is to conserve the batteries. However, in this position, the Inverter will charge the batteries until a utility power failure occurs. TEST/MUTE - In TEST mode, when ON MAINS LED is lit, on pressing this push button, the unit will do self test to determine the state of the system. During On Battery self test it will also show the load status which can be used to find out the load capacity. In the MUTE position (push in for 5 seconds), this push button switch silences the low battery buzzer. Circuit Breaker Switch (Rear Panel) - When in ON MAINS mode, if the system draws more than 10A, circuit breaker will trip. To reset the circuit breaker switch, push the switch fully inward. Inverter Indicators - The Inverter provides light emitting diode (LED) indicators (Figure 11) to show the operational condition of the Inverter and batteries. Indicators consist of Inverter Load Status (25%, 50%, 75%, 100%, and OVER LOAD). Other indicators consist of: INVERTER DISABLE, ON MAINS, ON BATTERY, and FAULT). Using Table 1, determine the condition of the Inverter and batteries. Page 9

25% 50% 75% 100% OVER LOAD AWAY TEST INVERTER DISABLE ON MAINS ON BATTERY FAULT INVERTER LOAD HOME MUTE Figure 11. Power Inverter Front Panel Controls and Indicators Table 1. Power Inverter Indicators Mode On Mains On Battery (yellow) Fault (red) INV Disable (red) 25% 50% 75% 100% Overload (red) Buzzer Description ON LINE On Off Off Off Off Off Off Off Off Off The unit is ON-LINE. ON LINE SELF TEST Flashing Off Off Off Off Off Off Off Off Off The unit is in ON-LINE Self- Test mode. ON BATTERY SELF TEST Flashing On Off Off On Off Off Off Off Off The unit is in ON-BATTERY Self-Test mode, and the load is less than 25%. Flashing On Off Off On On Off Off Off Off The unit is in ON-BATTERY Self-Test mode, and the load is between 25% - 50%. Flashing On Off Off On On On Off Off Off The unit is in ON BATTERY Self-Test mode, and the load is between 50% - 75%. Flashing On Off Off On On On On Off Off The unit is in ON-BATTERY Self-Test mode, and the load is more than 75% but less than oveload limit. Flashing On Off Off On On On On On Continuous beep for first 30 seconds for a fresh overload. ON BATTERY Off On Off Off On Off Off Off Off 4 beeps every 22 minutes Off On Off Off On On Off Off Off 4 beeps every 22 minutes Off On Off Off On On On Off Off 4 beeps every 22 minutes Off On Off Off On On On On Off 4 beeps every 22 minutes Off On Off Off On On On On On Continuous beep for first 30 seconds of a new overload. STANDBY ENABLE Off Off Off Off Off Off Off Off Off Short beep every 5 seconds The unit is in ON-BATTERY Self-Test mode, and is in an overload condition. The unit is in ON-BATTERY mode, and the load is less than 25%. The unit is in ON-BATTERY mde, and the load is between 25% and 50%. The unit is in ON-BATTERY mode, and the load is between 50% and 75%. The unit is in ON BATTERY mode; the load is between 75% and the overload limit. The unit is in ON-BATTERY mode, and is in overload condition (see NOTE below). The unit is shut down due to a LOW BATTERY. STANDBY Off Off Off Off Off Off Off Off Off Off The unit is in STANDBY mode, and is not powering the load. FAULT - Off Off Off Off On On On On On Off Iverter load capacity has been exceeded (see NOTE below). FAULT- Flashing Flashing Flashing Off Off Off Off Off Off Off The unit is in FAULT mode, contact APC Technical Support. FAULT- Off Off On Off Off Off Off Off Off Continuously On The unit is in FAULT mode, contact APC Technical Support. Page 10

Mode On Mains On Battery (yellow) Fault (red) INV Disable (red) 25% 50% 75% 100% Overload (red) Buzzer Description FAULT- On Flashing Flashing Off Off Off Off Off Off Chirps every 2.5 seconds; sound is mutable through the front panel TEST/ MUTE push button. BATTERY DISCONNECTED OVER TEMP ON- BATTERY OVER TEMP ON- LINE NOTE: In the case of a sustained overload, the Inverter will be turned off automatically after one minute, and will wait in the fault state for a minute. After that, it will restart again. If the overload still persists, the Inverter will be turned off again after one minute, and will wait in fault state for one minute and restart again. In the same way, it will try for three restarts. If the overload still persists, it will stay in fault state permanently until the unit is restarted with push button. If the time interval between two consecutive overloads is more than 5 mins, then the latest overload is considered as a fresh overload and three restart cycle will begin again. The unit is in FAULT mode, contact APC Technical Support. On Off Flashing Off Off Off Off Off Off Chirp every 2 seconds The unit is ON-LINE mode; battery is disconnected. Off Off 4 flashes every 2 second On Off 4 flashes every 2 second Off Off Off Off Off Off Continuously On The unit is in FAULT mode due to over- temperature condition. Off Off Off Off Off Off Off The unit is in ON-LINE mode, but the charger is switched off due to over- temperature. ON LINE On Off Off On Off Off Off Off Off Off The unit is in ON-LINE, but the inverter is disabled and the unit will not go ON BATTERY during a power failure. ON LINE SELF TEST Flashing Off Off On Off Off Off Off Off Off The unit is in ON-LINE Self- Test mode, but the inverter is disabled and the unit will not go ON-BATTERY during a power failure. ON BATTERY SELF TEST ON BATTERY Low Battery Warning ON BATTERY Low Battery Warning ON BATTERY Low Battery Warning ON BATTERY Low Battery Warning ON BATTERY Low Battery Warning Flashing On Off On On Off Off Off Off Off The unit is ON-BATTERY- Self-Test but the inverter is disabled and the unit will not go ON-BATTERY during a power failure. Off On Off Off On Off Off Off Off Constant Beeping, Can be muted through fron panel TEST/ MUTE push button. Off On Off Off On On Off Off Off Constant Beeping, Can be muted through front panel TEST/ MUTE push button. Off On Off Off On On On Off Off Constant Beeping, Can be muted through front panel TEST/ MUTE push button. Off On Off Off On On On On Off Constant Beeping, Can be muted through front panel TEST/ MUTE push button. Off On Off Off On On On On On Constant Beeping, Can be muted through front panel push TEST/MUTE button. Load is less than 25%. Load is between 25% and 50%. Load is between 50% and 75%. Load is between 75% and Overload limit. Load is more than overlaod limit. Page 11

Section 5. Troubleshooting Note: If the Power Inverter causes interference with a television while ON-BATTERY, move the television at least 3 feet away from the Inverter. Use the information provided in Tables 1 and 2 to diagnos Power Inverter problems. If the problem cannot be resolved using the information provided in this manual, contact APC Technical Support. Table 2. Power Inverter Troubleshooting Problem Cause Corrective Action Inverter fails to operate when mains power is turned on, or during a utility power failure. Computer load reboots when inverter switches to ON BATTERY. Inverter faults. Disconnected battery. Power is off at the Mains. Inverter HOME/AWAY switch in the AWAY position. Dead batteries. Inverter rear panel Push to Reset circuit breaker has tripped. Improper wiring installation or loose connection. Inverter transfer time too slow for computer load. Inverter drops the load. Inverter is overloaded. Ensure batteries are connected as defined in this manual. Turn on power at the Mains. Set switch to the HOME position. Inverter failed to charge batteries, or batteries were allowed to completely discharge. Replace batteries. If replacing the batteries does not fix the problem, contact APC Technical Support. Reset the circuit breaker by pushing it fully inward until it stops; release the circuit breaker. Ensure wiring is as described earlier in this manual, and that all connections are secure. For computer-type loads, a separate battery back-up (UPS) should be used, as the 60 millisecond transfer time is inadequate, and will cause the computer to reboot. Inverter may have an internal failure. If this happens, the unit can be disconnected from the mains by completion of a Manual Bypass (see Manual Bypass). Turn off some loads connected to the Inverter until the OVER LOAD LED is no longer lit Manual Bypass - In the event of an Inverter failure or dead battery condition, the Inverter can be disconnected from the mains and power restored to the circuit by completing a Manual Bypass (Figure 12) of the Inverter, as follows: Remove the Wiring Management Kit from the Inverter. Disconnect all wires connected at the Inverter rear panel. Connect the wire from the Input socket to the wire from the Output socket. Page 12

Push to Reset N INPUT L L OUTPUT N Input : 230V, 5A, 50Hz Output : 230V, 5A, 50HZ Disconnect from Inverter Connect Both Wires Completed Bypass Connection Figure 12. Power Inverter Bypass Connection Preventative Maintenance - Preventative maintenance consists of inspecting the batteries for cracks and/or leakage, and checking battery fluid levels and filling the batteries (every 120 days), using the criteria and methods as defined earlier in this manual. Dust the unit with a dry cloth. Do not use liquids when cleaning. Page 13

Specifications Input Characteristics Output Characteristics Surge Protection Table 3. APC Power Inverter Technical Specifications Item Nominal Voltage Rated Voltage Frequency Nominal Rated Current Input Circuit Breaker Rating Input Voltage Window for Utility Operation Voltage (on Mains) Voltage (on battery) Rated VA Rated Watts Nominal Rated Current Specification 230 V 230 V 47-53 Hz 3.47 A 10 A 100-265 VAC 100-265 VAC 210-240 VAC 800 VA 500 W 3.47 A Overload Indicated ON BATTERY >100% Shutdown due to OVERLOAD > 100% after 60 seconds (see Table 1 and following note) Frequency (ON BATTERY) 50 Hz +/- 1% Built-in Surge Protection Protects the load from surges and spikes.. Environmental Ambient Operating Temperature 0-45 degrees C Humidity Altitude 95 % Relative humidity, non-condensing 3000 m Physical Input Line IEC socket Outlet Receptacles Dimensions - Unit (h) x (w) x (d) Weight Shipping Weight IEC socket Main Housing Chassis: 51.2 x 47.5 x 43.0 cm Inverter Assembly: 13.0 x 50.6 x 29.3 cm Battery: 27.94 x 17.78 x 41.27 cm Main Housing Chassis: 18 kg Inverter Assembly: 13.5 kg Battery: 28 kg Main Housing Chassis: 20.5 kg Inverter Assembly: 14.5 kg Battery: XX kg (each) Batteries Type Two 12 V, 70 Amp-Hour Typical Runtime Typical Load Set Up Runtime at 500 W Typical Recharge Time (for a 90% Charge Following a 50% Discharge) AC Input Voltage Range for Charging Approximately 120 minutes Set-up A = 5 fans, 4 tube lights Set-up B = 4 fans, 4 tube lights, and 1 TV Approximately 120 minutes 8-10 Hours 100-265 V Page 14

Warranty APC warrants its products to be free from defects in materials and workmanship under normal use and service for 2 years for the Inverter, and 2 years for the Batteries to the original purchaser. Its obligation under this warranty is limited to repairing or replacing, at its sole option, any such defective products. To obtain service under warranty you must obtain a Return Material Authorization (RMA) number from APC Technical Support or an APC Service Center. The defective unit must be returned with an RMA number, with transportation charges prepaid and it must be accompanied by a brief description of the problem and proof of date and place of purchase. This warranty applies only to the original purchaser. Contact Information APC Corporate Office 132 Fairgrounds Road West Kingston, RI 02892, USA Tel: 401-789-0204 APC Corporate Office (India) 27 Lavelle Road Bangalore 560 001 www.apc.com Toll Free Helpline: 1600 444 272 and 1600 444 877 email: indiainfo@apc.com Technical Webchat: www.apc.com/in Page 15/Page 16 blank