TWIN FAN CONTROLLER. Models:- ITC and ITC-DS Maximum load : V 50Hz ~ 9A and V 50Hz 3 ~ 9A

Similar documents
Single Phase Electronic Speed Controllers

Vent-Axia Galaxy TM In-Line Belt Driven Twin Fans (GDB)

Galaxy TM In-Line Belt Driven Twin Fans (GDB)

FLÄKTGROUP PM-MOTOR WITH INTEGRATED FC 106 FREQUENCY CONVERTER

MAKING MODERN LIVING POSSIBLE. Quick Setup VLT FCM 300 Series. Phone: Fax: Web: -

Acoustic Twin Fans (ATQ)

Dycon D1532SM. EN50131/PD6662 Grade 3, 12V 2A Power Supply. Technical Description Installation and Operating Manual DYCON POWER SOLUTIONS LTD

Sentinel D-Box Twin Fan

ACC Series Power Conditioner OPERATION & INSTALLATION MANUAL

INFRESCO-S-4kW X20034 Issue: 7

Sentry Technical. Miniature Circuit Breakers (MCBs) Standards and approvals. Description. Technical specification

PSU EN54-4 Power Supplies

Central Battery Systems Loadstar AC/DC Systems

Dycon D2430 EN54-4 Fire Alarm Power Supply Series

INSTALLATION & MAINTENANCE MANUAL HBL

MODEL 520 REMOTE START ENGINE MANAGEMENT SYSTEM

LED AC DRIVERLESS FLOODLIGHTS WITH PIR FOR MODEL: FLAC10BPIR, FLAC20BPIR, FLAC30BPIR & FLAC50BPIR

DS DC1100 Energy Controller SELF CONFIGURING OPTIMISER/COMPENSATOR WITH BOILER SEQUENCE AND HWS CONTROL

Emergency lighting units EM converterled. EM converterled ST 90 V SELFTEST series

Emergency lighting units EM converterled. EM converterled ST 50 V SELFTEST series

icebreaker icebreaker A C G GE Lighting 2D lamps are fitted as standard. I44

HR25 Solo. Installation and User Instructions. Through the Wall Heat Recovery Ventilators

Advantage-D. Operating Instructions and Maintenance Manual. Central Vacuum Systems (Expandable/Modular Models) (Ver.

PBA Series Prelube Controls

RELAY BOX PRODUCT MANUAL IMPORTANT

Doc Ref: WD030/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

Auxiliary Status Switch Kit

Installation manual. Modbus Interface DIII EKMBDXA7V1. Installation manual Modbus Interface DIII. English

Installation Instructions

Combined Ventilation Controller RVWS-T-224HA

Burden Fuse Rating Resistor SAF / SAK6 1NM 10mm M8 12NM SAF / SAK10 2NM 16mm M8 12NM

Doc Ref: WD027/2/11/12 Fern-Howard Ltd. 2 Newman Lane, Alton, Hampshire, GU34 2QR. Reg. No

SBC / 2140 / Stage Battery Charger User Manual

Owners Manual: - Pumps

IGLOO IGLOO EASY INSTRUCTION MANUAL

ENGLISH NO Fan Starter INSTRUCTION MANUAL. Fan Starter 4. 4 kw 400 V 3~(+N) 50 Hz ART. NO

Quick guide. Plug-in fans GPPM with FC101_106 August 2014

SN1010 NATURAL VENTILATION CONTROLLER SET POINT

SOLID STATE POWER CONTROLLERS ACL-series AC1-series AC3-series ACF3-series DAC3- series

Hired Hand, Inc Co Rd 68 PO Box 99 Bremen, AL Manual Part No

ADS7 AC Contactor Starters

MANUFACTURED IN THE UK

ST - II Series POWER SUPPLIES USER INSTRUCTIONS

2.7. IT system floor-standing distribution cabinet Series -IPS-F

Phoenix Inverter

panasonic.net/id/pidsx/global Solve issues related to machine safety and other safety measures with a safety door switch with key!

2D products are warranted for one year, the expected life of the ballast and/or Emergency module is 5 years

SUBMERSIBLE WATER PUMP

Mizer Single Pump and Starter Box

OPERATION & MAINTENANCE INSTRUCTIONS

Twin and Single Inline Fans. Offers a range of flexible installation and application options, including auto-changeover on the Twin range

Operating & Maintenance Manual Compact Domestic Booster Set Model BTAF Arrow Valves

Elmdene International Ltd

Specification of Battery Charger

ACE Variable Frequency Drive System

Sentinel D-Box Single Fan

EdgeLED TM Range. Installation and Operating Instructions EdgeLED TM RANGE INSTALLATION NON-EMERGENCY LUMINAIRES PRE INSTALLATION

RE-PR3-E-86&105 3-Phase Panel Mount 86 and 105kW

SUM340 SUMMATION BOARD

Technical Specification

The 4HR-UPS 220V ac output is provided via a Pure Sine Wave inverter, allowing it to be backed up by 2x 12V standby batteries.

Emergency lighting units EM converterled

3 Pin Schuko Converter Plug Technical Data & Fitting Instructions

DEEP SEA ELECTRONICS PLC

TURBOTRONIK NT 151/361

EXI LED INTRODUCTION APPLICATION PRODUCT SPECIFICATION

TOWER MAXI T SINGLE CONVERSION ON LINE UPS SYSTEMS

Instruction Manual. Q Series 2 Motor Control Modules - OEM

On-Site Guide (BS 7671:2008 Wiring Regulations, incorporating Amendment No 1:2011)

Emergency lighting units EM converterled. EM converterled BASIC 200 V BASIC series

LED Emergency Luminaires

INDEX. SUPER VENT By Beta Industrial. pages INTRODUCTION CONSTRUCTION PERFORMANCE CHART ACOUSTIC DATA CHART DIMENSION SHEET - SINGLE CABINET FANS

Emergency lighting units EM converterled

Emergency lighting units EM converterled. EM converterled BASIC 90 V BASIC series

BENCHTOP INSTRUMENT. Single Channel DC Power Supply SL Series Operation Manual V1.0

LED emergency exit signage from Channel Safety Systems

3ph Belt Drive, Run & Standby, Roof & Plantroom Twinfans

FUM-24xxCBP Series 3 Stage Battery Charger User Manual

X20020 INFRESCO P 4kW Issue 4 User manual Date 16/02/16. Page 1 of 9 KEY FEATURES

Emergency lighting units EM converterled

Art. No. EC-315. Art. No. EC-330. Art. No. EC-340 SWITCH-MODE BATTTERY CHARGER CONTENTS IMPORTANT SAFETY PRECAUTIONS... 2

MAX. AC 600V HOLD V M H.V. LIVE CIRCUIT DIGITAL INSULATION TESTER DO NOT OPERATE IF LIT POWER DATA HOLD TEST ON / OFF 250V 500V 1000V OFF CAT.

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

C.fm Page 1 Thursday, February 21, :28 AM Raptor user manual

SUBMERSIBLE WATER PUMP

Installation instructions for ATS panel Ref:ATS --/2 M2GC705 Issue

Emergency lighting units EM converterled. EM converterled BASIC 50 V BASIC series

TPED /4-A-F-A-BQQE 3X400 50HZ

Frost protection for pipes. 16 Technical handbook. Thermostat with line or ambient temperature sensor

OPERATION & MAINTENANCE INSTRUCTIONS

Installation & User Instructions

250W PUDDLE PUMP WITH AUTO SENSOR MODEL NO: PSP105

EMEX Power. EMEX Power. Modular AC/AC Central Battery System. EMEX Power

AXUS AX High Temperature 300 C for 2hr, 400 C for 2 hour

Emergency lighting units EM converterled

OTEC Transfer switch open transition

SUBMERSIBLE WATER PUMP

ANZI Transfer Switch and Generator Wiring Installation Addendum

DEEP SEA ELECTRONICS PLC

DCE 100 Series Dust Filter

Transcription:

TWIN FAN Installation and Wiring Instructions Models:- ITC and ITC-DS Maximum load : 220-240V 50Hz ~ 9A and 380-415V 50Hz 3 ~ 9A IMPORTANT - READ THESE INSTRUCTIONS FULLY BEFORE COMMENCING INSTALLATION. 1. Ensure that the mains supply voltage, frequency, number of phases and power rating comply with the details on the rating label. Check that the controller can cope with the load (including starting current). 2. All wiring must be in accordance with current I.E.E. wiring regulations (BS7671), or the appropriate standards in your country. The equipment should be provided with a local all pole isolator switch having a contact separation of at least 3mm. We recommend that wiring to the equipment be made in conduit for added protection. 3. This equipment must be earthed. 4. Ensure safety regulations and practices are adhered to when installing and using this equipment. 5. The controller must not be used where it is liable to be subjected to water spray from hoses, etc., or where the ambient air temperatures may exceed 40 C. 6. When the fan motor thermal protector terminals (TK or TP) are brought out externally, they MUST be connected to the relevant controller terminals.

FOREWORD The Vent Axia twin fan controller range comprise of the following modules; 1. ITC Basic twin fan controller. 2. ITC-DS Twin fan controller with 12/24 hr duty sharing. 3. RVC Remote visual controller 4. RSC Remote setback controller Both the ITC and ITC-DS controllers have the following features; a. control both single and three phase fans if thermal overloads are fitted to the motors. b. fan failure indication to Building Management System (BMS) via voltage-free contacts. c. connection to external sensors (sensors must have voltage-free contacts). d. fan can be speed controlled using only one speed controller. The RVC module is used to indicate the status and to select the operation of the fans remotely (up to 100m away). Connections to the ITC and ITC-DS are Extra Low Voltage data link. The RSC is used to change the power supply to the fans (eg. switching between the mains supply and a speed controller). The selection of power supply can be achieved by any sensors or timers with voltage-free contacts. Connections between the RSC and the sensor are Extra Low Voltage. Contact your local Vent-Axia distributor for a full list of compatible sensors. MOUNTING 1. Install the controller in a ventilated area. ITC and ITC-DS can be fitted locally to the fans to reduced wiring cost and are rated to IP44. In this setup, RVC should be be used to indicate the status of the system at a remote location. 2. If the controller is mounted on metal or other conductive surface; that surface MUST be earthed. 3. Open the lid to gain access to the fixing holes. Securely mount the controller to the surface using appropriate fasteners. Route the supply and outlet cables through knock-out holes in the casing. OPERATING STATUS The ITC and ITC-DS has 2 LED's to indicate which fan is operating and a pushbutton to select either fan 1, fan 2 or standby mode. The relay contacts for BMS indications are used to indicate the following conditions: contacts#1 contacts#2 system condition closed closed system OK opened closed fan 1 failed closed opened fan 2 failed opened opened both fans failed or power failure FUSES The electronic circuit is protected by a 20mm long 1A time-lag (type T) fuse. The 24AC output is protected by a 20mm long 500mA time-lag (type T) fuse.

SUPPLY CONNECTIONS TO 220-240V ~ 50Hz SUPPLY 3 PHASE FANS TO 380-415V 3~ 50Hz SUPPLY WITH SPEED TO 220-240V ~ 50Hz SUPPLY 3 PHASE FANS WITH SPEED TO 380-415V 3~ 50Hz SUPPLY NOTE: IF THE SPEED S HAVE TK OR TP TERMINALS, A LINK SHOULD BE WIRED ACROSS THESE TERMINALS. SPEED SPEED

OUTLET CONNECTIONS WITH INTERNALLY WIRED THERMAL OVERLOAD PROTECTION. FAN 2 FAN 2 LINK WIRE LINK WIRE 3 PHASE FANS FAN 2 NOTE: 3 PHASE FANS MUST HAVE EXTERNALLY CONNECTED THERMAL OVERLOAD PROTECTION. NOTE: INSTALLER MUST PROVIDE ADEQUATE EARTH BONDING TO THE FANS

RSC CONNECTIONS EXTRA LOW VOLTAGE WIRING 220-240V ~ SUPPLY POWER SUPPLY No. 1. POWER SUPPLY No. 2. 240V INPUT 1 INPUT 2 RSC (10314230A) +Ve -Ve OUTPUT SELECTOR SWITCH ANY TIMER OR SENSOR WITH VOLTAGE - FREE CONTACTS ONLY REQUIRED IF USING 3 PHASE FANS ITC

GENERAL WIRING WARNING - ISOLATE MAINS SUPPLY BEFORE MAKING CONNECTIONS - THIS EQUIPMENT MUST BE EARTHED 1. All electrical connections should be made by a properly qualified electrician. 2. Wire the supply and outlet cables as shown in the wiring diagrams. 3. After making wiring connections, replace the lid onto the base and ensure the cable glands; gasket; etc. are securely located. NOTES ON RUNNING Both the ITC and ITC-DS operates by detecting the current flowing to the fan. If it is necessary to switch the fan on and off for any reason; e.g. fan off at night, this switching operation must be done via the ITC or ITC-DS controller by making or breaking the contacts connected across S1 - SG. Otherwise a fan failure will be registered. Before switching on CHECK: 1. All mountings are secure. 2. Circuit protection devices are fitted. 3. Earth connections have been made and are secure. 4. The fan is installed properly and the impeller is free to rotate. 5. All relevant guards are fitted. LAYOUT OF CONNECTIONS VOLTAGE-FREE CONTACTS TO BMS REMOTE VISUAL CONNECTIONS SUPPLY FOR ITC SUPPLY FOR FANS FAN 2 REMOTE 24V AC OUTPUT TO FAN 2 LED 1 LED 2 SENSOR CONNECTIONS OUTPUT TO LINK TO SELECT 24HR. CHANGE OVER. MODEL ITC-DS ONLY IS INSERTED HERE (12HR. IS SELECTED WITHOUT THE LINK IN PLACE)

RVC CONNECTIONS RVC EXTRA LOW VOLTAGE WIRING UP TO 100M LONG. FAN 2 FAN 1 REMOTE. 24V AC LED 1 LED 2 SENSOR CONNECTIONS AND BMS CONNECTIONS TO BMS STATUS (CONTACTS #1) TO BMS FAN 2 STATUS (CONTACTS #2) NOTE: IF A SENSOR IS NOT USED A LINK MUST BE WIRED ACROSS S1 - SG. (FACTORY PREWIRED). FAN FAN 2 1 REMOTE. 24V AC LED 1 LED 2 SENSOR WITH VOLTAGE - FREE CONTACTS EXTRA LOW VOLTAGE WIRING UP TO 25M LONG