Operation and Maintenance

Similar documents
Installation. InfraStruXure PDU 80kW PD80F6FK1-M-14 PD80F6FK1-M PD80G6FK1-M PD80G6FK1-M-14

InfraStruXure PDU Power Cable

AIS and 40 kva 400 V. Site Preparation and Installation Manual

Cable Ladders with Troughs and Partitions

PDU Input Power Cord. Before installation. Specifications

Bottom Hose Kit for the High-Density Cooling Enclosure ARACBH1

Operation. Smart-UPS TM VT Rack-mounted kva 200/208 V

Valve Box Assembly for the High-Density Cooling Enclosure ARACVB1

Power Distribution Units

Start UP Guide. Symmetra LX Tower Rack-Mount. UPS Models 200 V, 4-8 kva 208/240 V, 4-8 kva 220/230/240 V, 4-8 kva

Addendum. Remote Air-Cooled Condenser

Operation. Symmetra PX 48, 96, and 160 kw 400 V 100 kw 208 V

Smart-UPS RT External Battery Pack Stack/Rack-Mount 6U

Electrical Installation

Safety and General Information

Installation and Operation Back-UPS BX550CI-CN

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

Power Distribution Units AP9560 & AP9561

Symmetra PX. 48, 96, and 160 kw 400 V 100 kw 208 V. Operation 09/

Installation and Operation Manual Back-UPS BR1000-CH

Installation and Operation Manual Back-UPS BX1100CI-CN

Installation and Operation Manual Back-UPS BX800CI-ZA/BX1100CI-ZA

Installation Guide. Marine Filter SURT023M SURT024M

Broadband PowerShield. External Battery Pack 20 Ah 12 V Battery. User Manual

User Manual Back-UPS BX650CI-MS 230 Vac with AVR

Installation Guide Smart-UPS On-Line External Battery Pack XBP48RM1U-LI

Installation and Operation

BroadBand PowerShield. 20 AHr Battery. User Manual

Symmetra PX. 48, 96, and 160 kw 400 V 100 kw 208 V Operation 07/2017.

3000VA 120/208/230VAC

User Manual Easy UPS BV Series 500VA, 650VA, 800VA, 1000VA Safety and General Information

Broadband PowerShield. CP27U Models. User Manual

Installation Guide Smart-UPS X 2000/2200/3000 XL Tower/Rack-Mount 4U

User Manual Back-UPS BC500-RS, BC650-RS 650 VA 230 V

Smart-UPS VT Rack Mounted

Installation Guide Smart-UPS On-Line SRT1000/1500 UXI-NCLI, SRT1000/1500 UXI-LI, Tower/Rack-Mount

Smart-UPS VT kva 208/220 V. Site Preparation and Installation Manual

Back-UPS 650 VA 230 V with AVR (BX650CI-ZA)

Symmetra PX kw and 20 kw 208 V Operation 10/2016.

Extended Battery Cabinet for Nfinity

Galaxy kva 3:3 and 3:1. Receiving and Unpacking. 380/400/415 and 208/220 V 04/2016.

Symmetra PX. 48 kw 400 V, 96 kw 400 V, 100 kw 208 V, 160 kw 400 V. Receiving and Unpacking 01/2016.

w w w.apc.com Home Appliance & Lighting UPS HI800SQ Installation Guide and User s Manual

Installation Guide Smart-UPS On-Line SRT1000/SRT1500 XLA Tower/Rack-Mount

Single and Parallel Installation

APC Smart-UPS RT UX. User s Manual. Models SURT1000UXI and SURT2000UXI 220/230/240 Tower/Rack Mount Uninterruptible Power Supply.

User Manual. NetGuard IMPORTANT. PSD 650/1200/1600 Line Interactive UPS Uninterruptible Power Supply System. UPS Monitoring Software

Installation. Symmetra MW. 400 kw 480 V. UPS Summary UPS Summary. Normal Normal X017 X012 X008A X014A X014B X013 X008B X011 X405 X010 X007 X021

User Manual Easy UPS On-Line SRV Series 1000VA, 2000VA, 3000VA

Installation Guide Smart-UPS 1200/1500 VA 100/120/230 Vac Rack-Mount 1U

Bubble King. User Manual

Back-UPS CS Back-UPS CS 350

Smart-UPS RC External Battery Pack Tower/Rack-Mount 4U

User Manual. English. APC Smart-UPS. 750/1000/1500 VA 100/120/230 Vac 2U Rack-Mount Uninterruptible Power Supply

User Manual Easy UPS On-Line SRVS Series Rack-Mount 1000VA, 2000VA, 3000VA

Powerware Battery Charger Module. User s Guide. Models ASY-0652 and ASY

Power Inverter. Model BI800T and BI800F. w w w.apc.com. Installation Guide and User s Manual

CTFRP Series Power Supplies

Operation Manual. Smart-UPS C. Uninterruptible Power Supply 1000/1500/2000/3000 VA. 120/230 Vac. Tower. su0813a

Galaxy VM. Battery Breaker Box Installation 09/

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Installation and Operation Manual Back-UPS BR800/1100CI-IN

! "! User Manual Myers Power Products CTEP/G Manual 6/2009

Bubble Machine. User Manual

User Manual. English. APC Smart-UPS. 7500/10000 VA VAC 6U Tower/Rack Mount Uninterruptible Power Supply B 02/2004

MDX-645P INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

DP140e. Installation & Operations Manual

User s Manual. English. APC Smart-UPS RT. 3000/5000 VA VAC 3U Tower/Rack Mount Uninterruptible Power Supply

Galaxy Receiving and Unpacking 09/

n Operator s Manual n Redundant Control Unit FOR CFR UNINTERRUPTIBLE POWER SUPPLIES FROM ALPHA TECHNOLOGIES

M T E C o r p o r a t i o n MATRIX FILTER. SERIES B Volts, 50HZ USER MANUAL PART NO. INSTR REL MTE Corporation

Back-UPS ES APC Back-UPS ES, 6 outlet 350VA, 120V, without auto shutdown software

Single and Parallel Installation. MGE Galaxy kva 208/220 V

XPC-EBP64 External Battery Pack User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

MTE SERIES RLW. World REACTORS USER MANUAL PART NO. INSTR 030 REL MTE Corporation

Operation Manual. Smart-UPS Uninterruptible Power Supply. 1000/1500/2200/3000 VA 220 Vac. Rack-Mount 2U

Operation Manual. Smart-UPS. Uninterruptible Power Supply. Rack-Mount 1U. 1200/1500 VA 100/120/230 Vac

Technical Specifications. Symmetra PX kw 208 V

APC Smart-UPS RT UXI/UXICH

Installation and Operations Manual

Power Inverter. User s Manual. Diamond Series CPD1200EILCD

MDX-645 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

Installation, Maintenance and Warranty Flat Plate Battery

FieldView External Charger. User Guide

Symmetra PX 20 kw. InfrastruXure 208 V. Installation 01/

Solar Hybrid Power Generating System CPS1200EOH12SC CPS2200EOH24SC CPS3000EOH24SC. User s Manual K01-C

Earthing Principles. Symmetra PX 250/500 kw

Inlet Controller TC5-ITA USER'S MANUAL. M rev. 02 K rev. 00

Installation Power Management Unit Battery Cables and Battery Harness

Operation Manual. Smart-UPS. Uninterruptible Power Supply. 750/1000/1500/2200/3000 VA Tower 100/120/230 Vac. 500 VA Tower 100 Vac

Dual-Lite Trident TRF 40 Wide Battery Cabinet 20-40kVA Systems USER MANUAL

Valcom Failsafe Unit. 1620ESv2 SERIES. Operation and Maintenance Manual

Galaxy VM. Modular Battery Cabinets Installation GVMMODBCW, GVMMODBCN 09/

High Frequency SineWave Guardian TM

dv Sentry TM 208V 600V INSTALLATION GUIDE Quick Reference ❶ How to Install Pages 6 14 ❷ Startup/Troubleshooting Pages WARNING

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Introduction Safety precautions for connections... 3 Series 3700 documentation... 4 Model 3732 overview... 5 Accessories...

MDX-640 MDX-640 INSTRUCTION MANUAL. Battery Conductance Analyzer. For 6 & 12-volt automotive starting batteries

Electrically Held to Mechanically Latched Contactor

Safe & Secure Series Electric Actuator with Internal Battery Back-up Installation, Operation & Maintenance Manual

Transcription:

Operation and Maintenance Symmetra PX Battery Enclosure 80kW

Contents Safety... 1 ON, OFF & STAND-BY switch symbols..................... 1 Overview... 2 System Components Overview.......................... 2 Front view of battery enclosure......................... 2 Operation... 3 Operation Procedures................................ 3 How to perform a system start-up procedure with additional battery enclosures................................... 3 How to perform a total power off procedure............... 4 Troubleshooting..................................... 6 Maintenance... 7 Parts Replacement................................... 7 How to determine if you need a replacement part........... 7 How to return parts to APC............................ 7 User replaceable components.......................... 8 How to replace a card................................ 8 How to replace a battery module........................ 8 Directions for replacement............................. 9 How to store the battery modules...................... 10 Frame Adjustments................................. 11 How to adjust the battery enclosure.................... 11 How to reverse the door (if required for easier access to the battery enclosure) - steps 1-4............... 12 How to reverse the door - steps 5-8.................... 13 Symmetra PX Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

Safety Warning: ALL safety instructions in the Safety Sheet (990-2984) must be read, understood and followed. Failure to do so could result in equipment damage, serious injury, or death. For safety reasons, the trained user is only allowed to operate the display and replace the following parts: Battery module System Power Supply Card ing Card Battery Communication Card ON, OFF & STAND-BY switch symbols Indicates the ON position for a switch or breaker. Indicates the OFF position for a switch or breaker. Indicates the STAND-BY position for a switch or breaker. Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 1

Overview System Components Overview Front view of Battery Enclosure Battery Enclosure Empty 455 lb. (206 kg) 8 battery module bays Battery module (4 battery units) 4x50 lb. (4x23 kg) System Power Supply Card System Power Supply DC disconnect switch Battery Enclosure Address Switch (the plate must be removed to gain access) Cards Battery Enclosure Communication Card 2 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

Operation Operation Procedures How to perform a system start-up procedure with additional battery enclosures Note: The UPS is assumed to be powered and operating during this start-up procedure; if not, power up the UPS now. Note: A no good batteries fault will occur until at least one battery module is reinserted. 1 2 3 4 2 3 4 1 XR Battery Enclosure Address 2 3 4 1 XR Battery Enclosure Address 2 3 4 1 XR Battery Enclosure Address 2 3 4 1 XR Battery Enclosure Address Check that each battery enclosure is set to a different enclosure address in each battery monitor card. If not, remove all the batteries to the red disconnect line, and follow the procedure under Maintenance: How to replace a battery module. Set the DC disconnect switches in all your battery enclosures to the ON position. Wait 15 seconds for the battery enclosure to start up. The PowerView will display the following message: Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 3

Operation Operation Procedures LOAD ON ON BATT BYPASS FAULT # of batteries increased. Press any key... ESC? From the top-level menu, select status and scroll down to verify the battery unit count. Control Status Setup Accessories Logging Display Diags Help Top-Level Menu Bat Voltage: 218V Bat Capacity 100.0% Runtime: 01hr 30min 32 Batts, 0 Bad Sub-Sub-Status Screen From the top-level menu, select Diags, enclosure Status, and verify the enclosure count. Control Status Setup Accessories Logging Display Diags Help Top-Level Menu Enclosure: 2 of 2 Status: 32 of 32 Sub-System Raw Status Data Enclosure-Status Screen Note: If the total number of battery units or enclosures do not equal the amount in your configuration, ensure that all components are correctly installed (see the procedure Maintenance: How to replace a battery module). If the problem persists, see Troubleshooting. How to perform a total power off procedure Warning: All safety instructions in the Safety Sheet (990-2984) must be read, understood and followed prior to performing a total power off procedure. Note: For local, country-specific centers: go to www.apc.com/support/contact or see the back cover of the operation manual (990-4147) for phone numbers. Electrical Hazard: Before electrical installation/module handling begins, verify that all systems are in the total power off mode by following this procedure. 4 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

BATTERY UNIT Operation Operation Procedures Set the System Enable switch on the UPS to the STAND-BY position. Set the DC disconnect switch on the UPS and all battery enclosures in the system to the OFF position. Disconnect all the battery units by removing or pulling them out to the red disconect line. Caution: To ensure solid stability, do not pull battery units out beyond the red disconnect line unless completely removing them from the enclosure. Red disconnect line Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 5

Operation Operation Procedures Set the upstream utility/mains to the OFF or LOCKED OUT position. If the UPS has dual utility/ mains supply, set both supplies to the OFF or LOCKED OUT position. ON ON OFF OFF 6 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

Maintenance Parts Replacement How to determine if you need a replacement part To determine if you need a replacement part, contact APC Customer Support and follow the procedure below so that the APC Customer Support representative can assist you promptly: 1. In the event of a module failure, the display interface may show additional fault list screens. Press any key to scroll through these fault lists, record the information, and provide it to the representative. 2. Write down the serial number of the unit so that you will have it easily accessible when you contact APC Customer Support. 3. If possible, call APC Customer Support from a telephone that is within reach of the UPS display interface so that you can gather and report additional information to the representative. 4. Be prepared to provide a detailed description of the problem. A representative will help you solve the problem over the telephone, if possible, or will assign a return material authorization (RMA) number to you. If a module is returned to APC, this RMA number must be clearly printed on the outside of the package. 5. If the unit is within the warranty period, repairs or replacements will be performed free of charge. If it is not within the warranty period, there will be a charge. 6. If the unit is covered by an APC service contract, have the contract available to provide information to the representative. How to return parts to APC Call APC Customer Support to obtain an RMA number. To return a failed module to APC, pack the module in the original shipping materials, and return it by insured, prepaid carrier. The APC Customer Support representative will provide the destination address. If you no longer have the original shipping materials, ask the representative about obtaining a new set. Pack the module properly to avoid damage in transit. Never use styrofoam beads or other loose packaging materials when shipping a module. The module may settle in transit and become damaged. Enclose a letter in the package with your name, RMA number, address, a copy of the sales receipt, description of the problem, a phone number, and a check as payment (if necessary). Note: Damages sustained in transit are not covered under warranty. Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 7

Maintenance Parts Replacement User replaceable components Part Battery Enclosure Battery Module Battery Unit System Power Supply Card ing Card Battery Communication Card Part Number SYCF8BF SYBT4 SYBTU1 SYCSPS SYCBTMON SYCXRCOM How to replace a card Electrical Hazard: Only APC-trained personnel familiar with the construction and operation of the equipment, and the electrical and mechanical hazards involved, may install and remove system components. Loosen the Phillips screw at each side of the card. Carefully pull the card outward. Verify that the UPS display interface shows a message reporting that it has registered the removal. Port 1 Port 2 XR Communications Install the new card, carefully sliding the card on the guide rails in the card slot. Re-insert the Phillips screw at each side of the card and tighten. Verify that the UPS display interface shows a message reporting that it has registered the installation. How to replace a battery module Note: The UPS display will indicate the location of the faulty battery module (rows L1 through L8). Warning: Only trained persons familiar with the construction and operation of the equipment, as well as the electrical and mechanical hazards involved, may install and remove system components. 8 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

Maintenance Parts Replacement Caution: Wait until the system is ready to be powered up before installing battery modules in the UPS. Failure to do so can result in a deep discharge of the batteries and cause permanent damage (the time from the battery installation time till the UPS is powered up should not exceed 72 hours or 3 days). Directions for replacement Caution: Do not mix battery units. Replace with same model. Battery enclosures with four batteries in a row. APC recommends that a whole battery module (one row of batteries) is replaced at the same time to ensure optimal run-time (see example 1). However, it is only necessary to replace two batteries at the same time according to example 2 and 3 in the table below. ACCEPTABLE Column A Column B Column C Column D Example 1 New New New New Example 2 New New Old Old Example 3 Old Old New New The following examples are NOT acceptable: NON- ACCEPTABLE Column A Column B Column C Column D Example 1 Old New New Old Example 2 Old New Old New Use two people to lift components weighing between 18 32 kg/40 70 lb. Pxb0026a Holding the handle, gently lift the battery unit and pull it halfway out. A lock mechanism prevents it from being pulled all the way out. Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 9

Maintenance Parts Replacement Release the lock by pushing the battery unit upwards and pull the battery unit all the way out while supporting it. Take the replacement battery unit and push it into the system. Note: Allow for a 24-hour recharging period of the batteries after system start-up/battery replacement for battery monitoring data to become fully reliable. How to store the battery modules The battery modules must be stored indoors and with their protective packaging still in place. Ambient temperature: -15 to 40 C/5 F to 104 F Relative Humidity: 25-85% Non-condensing Storage place free from vibration, dust, direct sunlight, and moisture. Stored batteries should be recharged at regular intervals depending on the storage temperature: Storage Temperature Recharge interval -15 to 20 C/5 F to 68 F 9 months 20 to 30 C/68 F to 86 F 6 months 30 to 40 C/86 F to 104 F 3 months Caution: Do not store the batteries for more than 12 months. 10 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

Frame Adjustments If your UPS/battery enclosure has been moved to a new location, follow the below battery enclosure adjustment procedure, and, if applicable, the door reversal procedure. How to adjust the battery enclosure Caution: Do not move the enclosure after the stabilizing feet have been lowered as the feet may bend. Secure the enclosure by setting the stabilizing feet. After the electrical wiring has been completed, secure the enclosure in its final operating position. Use a 14-mm wrench (shipped with the enclosure) to adjust all 4 stabilizing feet until the pads make solid contact with the floor. Level the enclosure (optional). Adjust the stabilizing feet to level from the front to the back and from the left to the right. Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 11

Maintenance Frame Adjustments How to reverse the door (if required for easier access to the battery enclosure) - steps 1-4 1 Remove the handle 2 Rotate the handle 180 3 Re-install the handle 4 Remove the door 12 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

Maintenance Frame Adjustments How to reverse the door - steps 5-8 5 Remove thehinge pin brackets from their original positions (A) and re-install them to their new positions (B) (A) (B) (A) (B) 6 Remove the two door bumpers from their original positions (A) and re-install them to their new positions (B) (B) (A) (A) 7 Remove the latch plate from its original position (A) and re-install it to its new position (B) (B) (A) 8 Re-install the door Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001 13

Maintenance Frame Adjustments Troubleshooting This section will help you to solve most problems. If the problem persists, note the UPS/Battery Enclosure # and serial # before contacting APC Customer Support (back cover). Display Issues Meaning Corrective Action The battery monitor board LEDs do not light up or the PowerView displays an inaccurate number of battery enclosures. The PowerView displays an inaccurate number of batteries. The PowerView reports a battery unit fault. The PowerView reports a tripped internal DC disconnect switch. The battery enclosure(s) are not recognized. Unrecognized batteries in your configuration. A faulty battery has been detected. The DC breaker is open or the DC fuses are blown. Check that the communications cable(s) are connected, and that the battery enclosure selector switch(es) are in the correct position. Ensure that all batteries and/or communication cables are correctly installed. (See How to replace a battery module). (See How to replace a battery module). Verify the status of the DC breakers and check the fuses. 14 Symmetra PX 80 kw Battery Enclosure, Operation and Maintenance Manual - 990-1426B-001

APC Worldwide Customer Support Customer support for this or any other APC product is available at no charge in any of the following ways: Visit the APC Web site to access documents in the APC Knowledge Base and to submit customer support requests. www.apc.com (Corporate Headquarters) Connect to localized APC Web sites for specific countries, each of which provides customer support information. www.apc.com/support/ Global support searching APC Knowledge Base and using e-support. Contact an APC Customer Support center by telephone or e-mail. Regional centers Direct InfraStruXure Customer Support Line APC headquarters U.S., Canada Latin America Europe, Middle East, Africa Western Europe (inc. Scandinavia) (1)(877)537-0607 (toll free) (1)(800)800-4272 (toll free) (1)(401)789-5735 (USA) (353)(91)702000 (Ireland) +800 0272 0272 Japan (0) 35434-2021 Australia, New Zealand, South Pacific area (61) (2) 9955 9366 (Australia) Local, country-specific centers: go to www.apc.com/support/contact for contact information. Contact the APC representative or other distributor from whom you purchased your APC product for Entire contents copyright 2007 American Power Conversion Corporation. All rights reserved. Reproduction in whole or in part without permission is prohibited. APC, the APC logo, and TRADEMARK NAMES are trademarks of American Power Conversion Corporation. All other trademarks, product names, and corporate names are the property of their respective owners and are used for informational purposes only. 990-1426B-001 *990-1426B-001* 05/2007