Automatic Back-Flushing Filter AutoFilt RF9.

Similar documents
Automatic Back-Flushing Filter for Process Technology AutoFilt RF3.

Process Inline Filter Medium / High Pressure PFM / PFH

HYDAC Process Technology Gas Filters Product Overview

Backflushing Filter AutoFilt RF3

Automatic back-flushing filter AutoFilt RF4

EN / Modern Duplex Filters for Large Engines

Backflushing Filter AutoFilt RF4

HYDAC Process Technology Water Filtration Product Overview

Components and Systems for the Automotive Industry

HYDAC Quality for Pall Housings: Ecomicron 2-fit.

Process Inline Filter Protective filter PLF2-9HF

Process Inline Filter PLF1

Electrohydraulic Drive System EHC-A

Process screen basket filter PRFS

HYDAC AutoFilt Automatic Filters Product Overview

Merkel PRW 1 Double Wiper with Integrated Pressure Relieve. Product Information Merkel Hydraulics

HYDAC KineSys The energy-efficient drive system

Process Multi-Rheo Filter PMRF

HYDAC KineSys Motion Control Systems

Inline Filters for Process Technology

Change-Over Pressure Filter DFDK

AutoFilt RF3 Automatic Self-Cleaning Filter

AutoFilt RF3 Automatic Self-Cleaning Filter

Wärtsilä NO X Reducer. Environmental Efficiency

KAESER FILTER. KF F350 to F3360 Series Reliable purity for high flow rates Flow rate 35.4 to m³/min, Pressure 2 to 16 bar COMPRESSORS

E / HYDAC Control Cabinet Cooler HCC

Plug & Seal Fast-fit plug Connections for Housings, Pipe Ends and Assemblies. Product Information Special Sealing Products

modern, unique, versatile

Pressure Filter DF...K P, DF...M P, Flange Mounted

MAHLE Automatic Filter Series R8-30W

Spare Parts List Tank-Top Return Line Filter RFN with Elements to DIN up to 630 l/min, up to 10 bar

Pressure Filter for Manifold Mounting DFP and for Reversible Flow DFPF

Change-Over Inline Filter RFLD Welded Version

Process Technology. Product Catalogue.

Price List 2018 In-House Repairs and Calibrations

Standard filter Disk filter Return filter. Lubrication systems can fail from the following

Expertise. Hydraulics. What you should know about us. excellent pressure solutions

Replacement Elements

HYDAC LowViscosity Housings: Highest diesel quality on the whole transport route

Spare Parts List Filter NFD Change-Over Version

Profluid and Gap-type tube filters. Automatic filters

Change-Over Inline Filter AFLD to API 614

Diesel PreCare HDP up to 1800 l/h

Spare parts list Inline filter FLND switchable

Spin-on filter according to Bosch Rexroth standard: Type 50 SL 30 to 80D. Features. Contents. RE Edition:

Valve Technology and Special Solutions for Transmissions on Mobile Machines

Pressure Filter DF Pressure Filter for Reversible Oil Flow DFF/DFFX

METAL PUMPS GVSO. Vertical Chemical Centrifugal Pumps One Concept for Maximum Flexibility.

Return Line Filter RF

Quality features of genuine oil filters

Spare Parts List Return Line Filter RFM with 4-hole attachment

Spare parts list Return line filter RFM with 2-hole attachment

HYDRAULICS VINCKE HYDRAULIC PUMPS

CLAIRE TOTAL SAFETY CABINET TYPE B2 Safe for chemicals due to Total Exhaust

Inline Filter MFM. Flow rates up to 100 l/min Pressure range up to 280 bar Material: EN-GJS / steel E /01.04

Number Title Year Organization Page

Price List 2013 In-House Repairs and Calibration

Rotary Blowers Omega Series Air delivery from 0.5 to 160 m³/min Pressure up to 1000 mbar, vacuum to -500 mbar

Return Line Filter RFM with 2-Hole Mounting

Spin-on elements. Type 80, 81 and 82. Contents. Features. RE Edition:

Filter elements, two-stage for installation in wind turbines with Hydac filter housings. Type 65. Filter elements. Contents.

Filter Type PR-BW 100-FC. Filtration

Leadership in Filtration. MANN+HUMMEL Fuel Filters

Change-Over Diesel PreCare HDPD up to 1800 l/h

RFN Series Service and Parts

Innovative Element Technology for installation in HYDAC filters E / Quick Selection -

Return Line Filter HF4R up to 450 l/min, up to 10 bar

Safety Equipment for Hydraulic Accumulators

Filter elements for microfiltration. Type 46. CELLUDISC filter elements. Features. Contents. RE Edition:

Pressure Relief Valve DB12 CE

Filter Elements. for use in HYDAC filters* Pressure filter. Pressure filter. filter element (DIN 24550) elements. long seam weld

Inline Filter LPF D A Flange-Mounted up to 280 l/min, up to 25 bar

Spare Parts List Return line filter RF

2/2-Way Pressure Relief Valve CX DBV (Right-Angle Design)

PTFE seals for screw compressors

The D series CONTENTS. the single-cylinder diesel engine with revolutionary technology 4. -SILENT PACK environmentally friendly perspectives 5

SAMSON GROUP. Perfect Solutions. Local customer assistance across the world SAMSON AG. AIR TORQUE S.p.A. CERA SYSTEM GmbH. KT-ELEKTRONIK GmbH

Shell Alexia S4. Proven performance under tough conditions. Shell Marine Products

SKF Flowline. for circulating oil lubrication systems

Return Line Filter RFM with 4-Hole Mounting

HYDAC nitrogen charging units facilitate fast and cost effective filling or topping up of the required gas pre charge pressure in bladder, diaphragm

Spin-on filter according to Bosch Rexroth standard. Type 7 SL ; 7 SLS Features. Contents. RE Edition: Replaces: 01.

Proportional Pressure Reducing Valve PDM08130

Filter elements for installation in Pall filter housings. Type 16. filter elements. Contents. Features. RE Edition:

Perfectly Adapted. ISL Euro 6 Diesel Engine PS

LowViscosity Housing Filter LVH-F

Off-line Filters FNS 060. With flow control valve Operating pressure up to 320 bar Nominal flow rate up to 4 l/min e

PRODUCT BROCHURE AUTOMATIC AND MANUAL. filtration systems BOLLFILTER UK LIMITED

Duplex Filter Pi Features. Nominal pressure 40 bar (570 psi), nominal size 800 and 1100

LEISTRITZ PUMPEN GMBH. Screw Pumps & Systems. Storage-, Export- and Distribution Outlets

VERTICAL CHEMICAL CENTRIFUGAL PUMP MADE FROM METAL TYPE GVSO

Starting up hydraulic systems

Watz Hydraulik Your specialist for customised and standard hydraulic products

Air Cooler Industry AC-LN 8-14 / ACA-LN 8-11 / ACAF-LN 8-11

Meeting the Future of Combustion Engines

Return Line Filter RFM with 4-Hole Mounting

Duplex Filter Pi 3700

Automatic filter AF 173 G

Suction Filter SF/SFM/SFF and Suction Filter Elements S/S..

Duplex Filter Pi 2100

Transcription:

Automatic Back-Flushing Filter AutoFilt RF9.

AutoFilt RF9 Clearing the Way. The Challenge: In response to the Tier III standard which will come into effect in 2016, the International Maritime Organization (IMO) is placing tighter limits on the greenhouse gases, such as nitrogen oxide and sulphur oxide, produced by shipping. Marine engine builders are banking on common rail systems to reduce fuel consumption and exhaust gases, resulting in new requirements for efficient fluid management in marine engines. Efficient fluid management for marine engines. HYDAC's solution: To meet the resulting demand for cleanliness in marine fuels and lubricants, HYDAC presents the new AutoFilt RF9. This filter is a product of HYDAC's expertise and strong innovative drive. In combining the two disciplines, namely robust filtration and triedand-tested piston accumulators, a new, cutting-edge filter technology has emerged. What sets the AutoFilt RF9 apart is its patented hydropneumatic back-flushing technology, and secure media separation. Clean fuel, clean combustion, clean air. Heavy Fuel Oil Diesel Marine Diesel Oil / Marine Gas Oil Biodiesel oil Lubricating oil AutoFilt RF9. The specially developed filter elements with filtration ratings from 1 µm (absolute) offer low flow resistance and high contamination retention capacities. They also clean without leaving any residue. ECA (Emission Control Area) guidelines. You can benefit from robust filter technology with consistently high cleanliness classes for diesel fuels, too, up to ISO 11/8/7 and highly efficient back-flushing, all in one system. 2 Existing ECAs Planned ECAs Proposed ECAs Most used trade routes

On every sea. In every port. At the heart of filtration the AutoFilt RF9 covering all aspects of the marine engine. MDO / MGO HFO 1 HYDAC AutoFilt RF9 2 3 4 3 4 1 HYDAC AutoFilt RF9 5 LNG 6 HYDAC AutoFilt RF9 1 Heavy Fuel Oil Marine Diesel Oil / Marine Gas Oil Liquified Natural Gas Leakage oil Lubricating oil 1 2 3 4 5 6 7 HYDAC AutoFilt RF9 HYDAC Heat exchanger HYDAC Duplex filter HYDAC Metal bellows accumulator HYDAC Leakage oil module HYDAC Gas filter HYDAC Oil care system Lubricating oil 7 2 3

Robust filter technology on the outside. Qualities of the AutoFilt RF9 back-flushing filter. Back-flushing driven by external medium No mixing with the compressed air Adjustable back-flushing intensity Efficient hydraulic cleaning High cleaning efficiency No reduction in pressure during back-flushing Low compressed air consumption Low pressure drops Large filter surface for its compact size Low-maintenance, service-friendly design External heater possible Intelligent control system Terminal box Compressed air tank 4 Pneumatic control unit

Elementary filter qualities: Filter elements. Selection of filter materials.* Filter material Chemicron metal fibre Dutch weave Square mesh Depth filtration Surface filtration Surface filtration Stainless steel Stainless steel Stainless steel Filtration rating μm 1 to 100 25 to 60 100 to 500 Retention rate Absolute Nominal Nominal 400 400 400 Description Filtration Material Temperature C * Other materials and filtration ratings on request and dependent on the particular operating conditions. 5

Back-flushing that makes the difference. Filtration Consistent filtration performance. The medium enters the filter housing via the inlet and is distributed evenly to the different filter chambers. One cleaned filter chamber is always on stand-by. The flow direction through the filter elements (A) in the chambers is from the outside to the inside. The contamination is separated from the fluid on the outer surface of the filter element and is retained there. The cleaned medium leaves the various filter chambers, collects in the upper part of the filter housing and exits the filter through the outlet. As the level of contamination in the filter elements increases, the differential pressure in the filter increases. Preparing to flush Without interrupting the filtration. When the differential pressure in the filter reaches the pre-set value, back-flushing is initiated. Back-flushing can also be carried out manually or at set intervals. When back-flushing is initiated the gear motor turns the back-flushing unit (B) to the next filter chamber. As the unit turns, the cleaned filter element is released from stand-by and the differential pressure is re-set. A sensor stops the gear motor from turning the back-flushing unit as soon as it reaches the new filter chamber. The back-flushing valve (C) and the piston accumulator diaphragm valve open simultaneously. A A 6

Back-flushing With excellent efficiency. The energy stored in the compressed air moves the back-flushing piston (D), forcing the filtrate to flow in the reverse direction through the filter elements. The contaminated particles are detached from the filter material and discharged through the open back-flushing port. When the back-flushing piston (D) has reached its end position both the back-flushing port and piston accumulator diaphragm valve close. It takes less than a second to clean the filter element. The back-flushing chamber is refilled via the filling bore and the piston returns to its starting position; in other words the accumulator is charged with the filter's own cleaned medium, ready to clean another filter element. B D C 7

Best Performance! The merits of the AutoFilt RF9 are what make the difference to performance, quality and service life. Filter elements held securely: Back-flushing piston: Pneumatic control unit: Special design to hold filter elements securely A lug in the filter chamber prevents the filter element from working loose or falling out Easy to handle - No tools or specific torque required - Filter elements can easily be screwed in by hand by the user Changing the filter element Changing the element is quick and easy - simply remove the filter cover plate Piston accumulator diaphragm valve: Powerful cleaning - The piston accumulator diaphragm valve is equipped with a special high temperature diaphragm - This diaphragm ensures that a large fluid mass is used and moves the piston at a constant discharge speed Cleaning without any residue - The filtrate is pushed with high kinetic energy through the filter material in the opposite direction to the filtration - Deposits and contaminants are very effectively detached from the filter material and discharged via the back-flushing line Guaranteed separation of filtrate and compressed air - Cleaning is carried out using its own cleaned medium (filtrate) - The external energy required for cleaning the filter elements is provided by compressed air Special H design Permits installation in any position Flushing device: Optimized flow dynamics - Maximum flow cross-section of inlet and outlet on back-flushing unit is guaranteed to allow for tolerances - Special design to compensate for casting tolerances and prevent the flow losses that arise when openings are identical in size Flexible design Reliable filter operation is guaranteed by the fact that the gear motor does not need to be set to a specific direction of rotation Optimum adaptability for every application The filling bore is specially designed to take different sized orifices for optimal charging of the accumulator Variable adjustment of the back-flushing pressure optimizes the back-flushing process Back-flushing port: Can be configured to suit installation situation - The back-flushing port can be rotated through 360 in 90 steps - Space-saving positioning Trace heating (optional): Start not dependent on temperature Highly viscous media such as heavy diesel oils can be pre-heated for a cold start. Potential heat losses are offset. Choice of heating media Various heating media can be used: - Hot water (Tmax / Pmax ) - Steam (Tmax / Pmax ) - Thermal oil (Tmax / Pmax ) 8

Innovative filter technology on the inside. Gear motor with position monitoring Differential pressure monitoring Filter chamber Outlet Inlet Back-flushing line Pressure release valve 9

FluidCareCenter. Surface filtration. Expertise when it comes to filtration. Know-how produces efficient solutions: The FluidCareCenter at HYDAC. High flow test rig: Essentially, the particles are separated at the surface of the filter material. Once a pre-set pressure drop is achieved or according to fixed intervals, the filter materials are cleaned and the filtration process can continue continuously or intermittently. Retention rate - nominal: The test filter must retain 90-95 % of all particles larger than the given filtration rating. Depth filtration. To provide the right environment to develop, revise and optimize filtration solutions tailored to specific applications, HYDAC has established its own research and development centre, the only one of its kind in the world. At the HYDAC FluidCareCenter we have built up a wealth of knowledge of media and their properties, we put new developments to the test and our visions become new products. Flow rate test rig to determine a filter's flow capacity. Hydromechanical test facility / Universal test rig: Measurement of: Collapse burst pressure to ISO 2941 Flow fatigue resistance to ISO 3724 Flow characterisitics to ISO 3968 The fluid being cleaned penetrates the filter structure. The contaminating particles become trapped in the deeper layers of the filter. The flow resistance increases as the media becomes more and more clogged, with the result that the filter element must be back-flushed. Retention rate - absolute: The test filter must retain at least 99.5 % of all particles larger than the given filtration rating. All the knowledge held collectively in the HYDAC FluidCareCenter reaches far beyond the visible technology. In addition to the systematic analysis of fluids, we are commissioned to run tests based on good science and issue corresponding reports. Our objective is to develop machines and systems which are optimized for lubrication applications. This know-how, together with the product range across the whole HYDAC group, creates synergies which are reflected in the AutoFilt RF9. The RF9 combines state-of-the-art filtration with proven piston accumulators to produce a high-end solution. Bubble point test rig: Cold start test rig: Simulation of cold start conditions on filters. Multi-pass test rig: Filtration efficiency and contamination retention capacity determined by multi-pass test to ISO 16889. 10 Quality testing for filter elements to ISO 2942.

The filter which grows with the task. The AutoFilt RF9 is highly versatile. HYDAC's AutoFilt RF9 was designed for use on ships and complies with the design specifications of all international classification organizations. AutoFilt RF9 RF9-0 RF9-1 RF9-2 RF9-3 RF9-4 RF9-5 RF9-6 RF9-7 RF9-8 RF9-9 Connection (DN) 25 / 32 / 40 / 50 32 / 40 / 50 / 65 40 / 50 / 65 50 / 65 / 80 65 / 80 / 100 100 / 125 125 / 150 150 / 200 200 / 250 250 / 350 Design PED 97/23 EC AD 2000 Material EN-GJS-400-15 / DIN EN 1563 / AD 2000 W3/2 Permitted operating pressure Permitted test pressure Permitted operating temperature Weight 120 kg 270 kg 295 kg 320 kg 370 kg 480 kg 540 kg 630 kg 1050 kg 1200 kg Volume 20 l 40 l 45 l 50 l 60 l 110 l 130 l 150 l 320 l 360 l No. of filter chambers 2 2 3 4 6 4 6 8 6 8 Pilot air supply Back-flushing process Back-flushing medium 4- / 58- Hydropneumatic back-flushing with secure media separation Filtrate Volume per flushing 1.1 l 5.0 l 5.0 l 5.0 l 5.0 l 9.0 l 9.0 l 9.0 l 17.7 l 17.7 l Air consumption per flushing 0.03 m³ 0.03 m³ Flushing duration < 2 sec. < 2 sec. < 2 sec. < 2 sec. < 2 sec. < 3 sec. < 3 sec. < 3 sec. Trace heating (optional) 2 2 2 2 4 2 4 4 Permitted operating pressure Permitted test pressure Permitted operating temperature Heating medium 11

Cooling Systems 5.700 Electronics 180.000 Accessories 61.000 Compact Hydraulics 53.000 Filter Systems 79.000 Process Technology 77.000 Filter Technology 70.000 Accumulator Technology 30.000 Global Presence. Local Expertise. www.hydac.com HYDAC Head Office HYDAC Companies HYDAC Sales and Service Partners Head Office HYDAC PROCESS TECHNOLOGY GMBH Industriegebiet Grube König Am Wrangelflöz 1 66538 Neunkirchen Germany Tel.: +49 6897 509-1241 Fax: +49 6897 509-1278 E-Mail: prozess-technik@hydac.com Internet: www.hydac.com