Instruction Manual IVT-10 / IVT-20 Voltage Tester

Similar documents
Instruction Manual ICM A1 AC/DC Clamp Meter ICM A1

Instruction Manual. IM-191 Magnetic Field Meter

INSTRUCTION MANUAL IDM67 DIGITAL MULTIMETER

INSTRUCTION MANUAL IDM93N DIGITAL MULTIMETER EN FR IT DE

INSTRUCTION MANUAL IDM91E DIGITAL MULTIMETER EN FR IT DE JP

ICA 39T INSTRUCTION MANUAL ICA39T AC/DC CURRENT TRANSDUCER

INSTRUCTION MANUAL IDM97II DIGITAL MULTIMETER EN FR IT DE

362 Clamp Meter. Users Manual

362 Clamp Meter. Users Manual

Instruction Manual. IT-1 Infrared Thermometer

Users Manual. Phase Rotation Indicator

365 Detachable Jaw True-rms Clamp Meter

323/324/325 Clamp Meter

373 Clamp Meter. Users Manual

Phase Sequence Tester

302+/303 Clamp Meter. Users Manual

DT33B/C/D OPERATOR S MANUAL LIMITED WARRANTY AND LIMITATION OF LIABILITY

MY /2-DIGIT DIGITAL MULTIMETER Users Manual

RS-3 PRO RS-1007 PRO. CAT IV Analog Clamp meter Series. Users Manual. For detailed specifications and ordering info go to

The following table shows the symbols used on the product and/or in this manual. Hazardous Voltage. Risk of electric shock.

KMP Insulation-Continuity Tester. Users Manual

Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com INSTRUCTION MANUAL PSMR1

Users Manual. Accessories Motor and Phase Rotation Indicator ships with the following items: 3 test leads 3 test probes 3 alligator clips 9 V battery

i400s Calibration Information Introduction

INSTRUCTION MANUAL CM95/ CM100 TRUE RMS FLEXIBLE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Instruction Manual VT4 VOLTAGE TESTER. Check out what else you can get from Martindale:

DIGITAL RCD(ELCB) TESTER

i3000s/i2000 Flex AC Current Probe

MM300. INSTRUCTION MANUAL Manual-Ranging Digital Multimeter

OPERATING INSTRUCTIONS

Dawson DDM190D. Digital Multimeter User s Manual

BT508/BT510/BT520/BT521 Battery Analyzer Safety Sheet

Calibration Manual. Detachable Jaw True-rms Clamp Meter

233 True-rms Remote Display Digital Multimeter Safety Information

Users Manual. MegOhmMeter

PY-11 Voltage & Continuity Tester

Digital Multimeter User's Manual

AC50A. Leakage Clamp Meter. User Manual. For detailed specifications and ordering info go to

Instruction Manual PC104/PC105 3-PHASE SOCKET TESTER. Check out what else you can get from Martindale:

Calibrator Capabilities Function Range Resolution Measure V dc 28 V 1 mv Measure ma dc Source ma dc

1.Safe testing IMPORTANT:

INSTRUCTION MANUAL CM69 TRMS AC EARTH LEAKAGE CLAMP METER. 1. SAFETY INFORMATION: Always read before proceeding. REMEMBER: SAFETY IS NO ACCIDENT

Table of Contents Title Page No.

PRM-4. Phase Sequence and Motor Rotation Tester. Users Manual. For detailed specifications and ordering info go to

1662/1663/1664 FC. Electrical Installation Tester. Safety Information. Warnings

INSTRUCTION MANUAL DM5B Fax: (503)

1587 FC/1587/1577. Insulation Multimeter. Safety Information. Warnings

Mini Multimeter with Non-Contact Voltage Detector (NCV)

USER MANUAL. 200A AC Mini Clamp Meter. Model MA130. Please visit for user manual translations

OPERATING INSTRUCTIONS

OPERATING INSTRUCTION

Instruction Manual VT25 / VT28 VOLTAGE TESTER ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

AMB V Insulation Resistance Tester. Users Manual. For detailed specifications and ordering info go to

Vol-Con XL (61-086) Voltage/Continuity Tester and Vol-Test (61-085) Voltage Tester Instruction Manual WARNING

User Guide. Model Insulation Tester / Megohmmeter. Introduction

Table of Contents. Title Page UT501/UT502 OPERATING MANUAL. Introduction. Unpacking the Meter. Safety Information. International Electrical Symbols

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Instruction Manual. Model 2831D 4 ½ Digit True RMS Digital Multimeter

INSPECTOR LINE LOAD SIMULATOR INSTRUCTION MANUAL TASCO, INC.

Autoranging Industrial Multimeter

LH41A. User Manual. Clamp On Ammeter. For detailed specifications and ordering info go to

ASTROAI USER MANUAL DIGITAL MULTIMETER. NOTE: Fully read and understand this manual before using this instrument.

User's Manual. High Voltage Megohmmeter. Analog Insulation Tester plus AC Voltage and Continuity Tests. Model

DIGITAL INSULATION RESISTANCE TESTER (5KV, 1T )

INSP-3 Wiring Inspection Tester

Instruction Manual. 99 Washington Street Melrose, MA Fax TestEquipmentDepot.com. Model 308A Digital Insulation & Continuity Meter

DIGITAL MULTIMETER INSTRUCTION MANUAL

Cable Length Meter INSTRUCTION MANUAL

USER MANUAL. Insulation Tester + DMM. Model MG320

Visit us at

Go to to register your product and find more information.

True RMS Autoranging Multimeter

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

EZYPAT / EZYPAT+ / SMARTPAT PORTABLE APPLIANCE TESTER INSTRUCTION MANUAL

OPERATING INSTRUCTION

PURE SINE WAVE DC TO AC POWER INVERTER

KMP7010. Ground Resistance Tester. Users Manual

TX900. Microwave Leakage Detector. 99 Washington Street Melrose, MA Phone Toll Free

Instruction manual. High voltage insulation resistance tester KEW3121B/3122B

Mini Multimeter with Non-Contact Voltage Detector (NCV)

INSTRUCTION MANUAL DT173 DT175 DIGITAL THERMOMETERS ALWAYS READ THESE INSTRUCTIONS BEFORE PROCEEDING

Autoranging Multimeter

BK BK A BK MA BK MA BK J93 MN93-BK MN193-BK MR193-BK SL261-BK SR193-BK

MOdel No: MM19.V3 WARNING CAUTION 1. SAFETY INSTRUCTIONS

51 & 52 Series II. Users Manual. Thermometer. Test Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.

& HIGH CURRENT DC POWER SUPPLIES INSTRUCTION MANUAL


Low Amp Probe EETA308A

For technical questions and replacement parts, please call

THERMOCOUPLE CALIBRATOR Mode KM-CAL-710

INSTRUCTION MANUAL ANALOGUE INSULATION TESTER KEW 3131M KYORITSU ELECTRICAL INSTRUMENTS WORKS,LTD., TOKYO JAPAN

Model Insulation Tester / Megohmmeter. User Manual

DT304. Digital Temperature Logger INSTRUCTION MANUAL

TIC 300 PRO. Users Manual Mode d emploi Bedienungshandbuch Manual d uso Manual de uso. Non Contact AC Voltage Detector. High Energy Tic Tracer

Nature Power Inverters. True Sinewave Inverter Modified Sinewave Inverter. Owner s Manual

KEWTECH. KT56 digital multi function tester. Instruction manual

IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL IN1001/IN1003 ANALOGUE INSULATION & CONTINUITY TESTERS INSTRUCTION MANUAL

Digital/Analog Megohmmeter Model 1026 USER MANUAL

Model ST Instruction Manual. Digital Insulation Tester. reedinstruments. www. com

Dawson DAN100. Analog Multimeter User s Manual

TMULD-300 ULD-300. Ultrasonic Leak Detector. Users Manual. 99 Washington Street Melrose, MA Phone Toll Free

Transcription:

Instruction Manual IVT-10 / IVT-20 Voltage Tester EN

1. Safety Safety Information To ensure safe operation and service of the Tester, follow these instructions. Failure to observe warnings can result in severe injury or death. - Avoid working alone so assistance can be rendered. If the operators safety can not be guaranteed, the Tester must be removed from service and protected against use. - Prior to usage ensure perfect instrument function (e.g. on known voltage source) before and after the test. - Do not connect the instrument to voltages higher than 750V. - Do not open the battery cover before take off from voltage source. - The safety can no longer be insured if the Tester : shows obvious damage does not carry out the desired measurements has been stored for too long under unfavorable conditions has been subjected to mechanical stress (i.e. during transport). - All relevant statutory safety regulations must be adhered to when using this instrument. - The Tester may no longer be used if one or several functions fail or if no functionality is indicated or the Tester looks damaged. - When using this Tester, only the handles of the probes may be touched do not touch the probe tips (metal part). - Do not use the Tester if the Tester is not operating properly or if it is wet. - Use the Tester only as specified in the Instruction card including environmental conditions and the usage in dry environments must be followed or the protection by the Tester might be impaired. - Use extreme caution when working around bare conductors or bus bar. Contact with the conductor could result in an electric shock. - Use caution with voltages above 50V AC rms or 110V DC. These voltages pose a shock hazard. 1

2. Symbols and Features Symbols as marked on the Tester and Instruction manual Risk of electric shock See instruction manual + or - + DC or DC measurement Equipment protected by double or reinforced insulation Battery Earth ± AC measurement Conforms to EU directives High Voltage Detection List of features AC Voltage DC Voltage Continuity Resistance (only on IVT-20) Single pole phase test Phase rotation of a three-phase mains Frequency test (only on IVT-20) Auto test Probe tip torch Drop proof 1 meter IP 65 Protection Auto Power On/Off Selectable probe tips 2/4 mm 2

3. AC/DC V Measurements AC V DC V IVT-10 : The safety LED can report a dangerous voltage> 50 V AC and 120 V DC IVT-20 : The safety indicator can report a dangerous voltage > 50 V AC and 120 V DC. If the tester is used in a noisy background, you need to ensure that the soundlevel of the tester is perceptible here. 3

4. Continuity / Diode Test Continuity Tests Diode Tests IVT-10 4

IVT-20 The Continuity / test is only possible when batteries are installed and in good condition. 5

5. Resistance Measurements Only on IVT-20 The Resistance test is only possible when batteries are installed and in good condition. 6. Single-Pole Phase Test Single-Pole Phase Firmly 6

The single-pole phase test is only possible when batteries are installed and in good condition. The single-pole phase test is not always appropriate for testing whether a circuit is not live. For this purpose, the bipolar test is required. To determine external conductors during phase tests the display function may be impaired (e.g. for insulating body protection or insulating sites). Firmly grasp the insulated grips of the Tester probe L2 it is better for increase the sensitivity of single-pole phase test. 7. Phase Rotation Test Rotary phase of a three-phase mains Right rotary field Firmly 7

Left rotary field Firmly Testing of phase-sequence direction is possible from 100V AC voltage (phase to phase) provided the neutral is earthed. On making contact with both test electrodes (probe tips) to two phases of the three-phase power supply which are connected in clockwise rotation, a B symbol appears in the LCD Display. If the rotation is anticlockwise, then a C symbol is displayed. In this case both phases of the unit should be switched around. Note : Testing the phase rotation always requires a negative phase rotation test! To ensure a connect test, it is better to test on a known source. 8

Attention : Please ensure that the test electrodes (probe tips) make good contact with two phases of a three-phase mains while testing the phase rotation. For absolute determination of a clockwise phase rotation it is necessary to make a negative phase rotation test after changing the phases. The indication B or C can be affected by unfavorable light conditions, by protective clothing or in insulated locations. Firmly grasp the insulated grip of the Tester probe L2, it is better for the sensitivity of the phase rotation test. 8. RCD Voltage Test Voltage Test with RCD Trip Test During voltage tests in systems equipped with RCD circuit breakers, a RCD switch can be tripped at a nominal residual current of 10mA or 30mA by measuring the voltage between L and PE. These Testers IVT-10 / IVT-20 are equipped with an internal load enabling the tripping of an RCD protection device of 10mA or 30mA. 9

To avoid RCD tripping, a test has to be carried out between L and N during approx. 5sec. Immediately afterwards, voltage testing between L and PE can be carried out without RCD tripping. 9. Illumination Probe tip torch 10

10. Frequency Tests Only on IVT-20 11. Auto Tests If the instrument shows failue, please don t use it and send it to our service department for repair. 11

12. Battery Replacement If no signal sound is audible (IVT-10) when short circuiting the test probes, if the symbol < is displayed (IVT-20) - Completely disconnect IVT-10 /IVT-20 from the measurement circuit. - Unscrew the screw by a cross screw driver, then open the battery cover. - Remove discharged batteries. - Replace by new batteries, type 1.5V IEC LR03 by respecting correct polarity. - Close the battery cover and re-screw the screw. 13. 4mm Tips Replacement 12

14. Cleaning Prior to cleaning, remove the instruments from all measurement circuits. If the instruments are dirty after daily usage, it is advisable to clean them by using a damp cloth and a mild household detergent. Never use acid detergents or dissolvent for cleaning. After cleaning, do not use the voltage tester till it is dried completely. 15. Transport and Storage In order to avoid instrument damage, it is advised to remove batteries when not using the instrument over a longer period. The tester must be stored in dry and closed areas. In the case of an instrument being transported in extreme temperatures, a recovery time of minimum 2 hours is required prior to instrument operation. 16. Maintenance Unauthorized persons shall not disassemble the tester and the supplementary equipment. When using tester IVT-10 /IVT-20 testers in compliance with the instruction manual, no particular maintenance is required. If functional errors occur during normal operating, our service department will check your instrument without delay. 13

17. Specification The Instruments IVT-10 IVT-20 Voltage range LED/Bargraph resolution LCD voltage range LCD resolution Accuracy Voltage detection Acoustic signal sound Polarity detection Range detection Response time Frequency range Automatic load (RCD) Peak current Operation time Recovery Time Auto Power On 12.750V AC/DC ± 12,24,50,120,230,400, 750V Automatic AC 50V DC 120V Full range Automatic <0.1s 12V 750V AC/DC 1V DC, 45 65Hz Yes AC ±(1.3%+5d) DC ±(1.0%+2d) <0.1s/BAR <2s/RDG Is <0.2A / Is(5s) <3.5mA ED (DT)=30s. 10 min. >12 VAC / DC Single-pole Phase Test Voltage range Frequency range Resistance Test Resistance Range Accuracy Resolution Frequency Test Frequency range Accuracy Resolution Vmin (61Hz~999Hz) 100 750V AC 45 65Hz 0 2KΩ ±(2%+10d) 1Ω 30Hz~999Hz ±(0.3%+5d) 1Hz 20VAC 14

The Instruments IVT-10 IVT-20 Continuity Test Threshold < 200KΩ < 200Ω Diode Test 0.1~1.0V Resolution 0.1V Overvoltage protection 1000V AC/DC Rotary Field Indication Voltage range (LEDs) Frequency range Measurement principle Power supply Power consumption 100 750V 50 60Hz Double-pole and firmly hold the grip (L2) 2 x 1.5V IEC LR03 AAA size Max. 32mA / approx. 94mΩ Operating Temperature -15ºC ~ 45ºC Storage Temperature -20ºC ~ 60ºC Temperature Coefficient Humidity Height above sea level Pollution Degree 2 Type of protection 0.2x(Spec.Accuracy/ºC <18ºC >28ºC Max. 85% relative humidity Up to 2000m IP65 CE EN61326 : EN55011 : Safety EN61010-1 : 2010 EN61010-031 : 2008 EN61243-3 : 2010 UTE 18-510 EN60529 : 2000/AI2000 GS38 Functionality EN61243-3 : 2010 EN61557-7 : 2007 EN61557-10 : 2001 EN 61557-1 : 2007 Weight 230g (IVT-10), 240g (IVT-20), (incl. Batteries) Dimensions 239x68x29mm 15

Overvoltage category Overvoltage class CAT. CAT I CAT II CAT III CAT IV CAT III 1000V/CAT IV 600V Application field The circuits not connected to mains. The circuits directly connected to Low-voltage Installation. The building installation The source of the Low voltage installation. 16

Limited Warranty This meter is warranted to the original purchaser against defects in material and workmanship for 3 years from the date of purchase. During this warranty period, RS Components will, at its option, replace or repair the defective unit, subject to verification of the defect or malfunction. This warranty does not cover fuses, disposable batteries, or damage from abuse, neglect, accident, unauthorized repair, alteration, contamination, or abnormal conditions of operation or handling. Any implied warranties arising out of the sale of this product, including but not limited to implied warranties of merchantability and fitness for a particular purpose, are limited to the above. RS Components shall not be liable for loss of use of the instrument or other incidental or consequential damages, expenses, or economic loss, or for any claim or claims for such damage, expense or economic loss. Some states or countries laws vary, so the above limitations or exclusions may not apply to you. For full terms and conditions, refer to the RS website. 17

Africa RS Components SA P.O. Box 12182, Vorna Valley, 1686 20 Indianapolis Street, Kyalami Business Park, Kyalami, Midrand South Africa www.rs-components.com Asia RS Components Pte Ltd. 31 Tech Park Crescent Singapore 638040 www.rs-components.com China RS Components Ltd. Suite 23 A-C, East Sea Business Centre Phase 2, No. 618 Yan'an Eastern Road Shanghai, 200001 China www.rs-components.com Europe RS Components Ltd. PO Box 99, Corby, Northants. NN17 9RS United Kingdom www.rs-components.com Japan RS Components Ltd. West Tower (12th Floor), Yokohama Business Park, 134 Godocho, Hodogaya, Yokohama, Kanagawa 240-0005 Japan www.rs-components.com U.S.A Allied Electronics 7151 Jack Newell Blvd. S. Fort Worth, Texas 76118 U.S.A. www.alliedelec.com South America RS Componentes Limitada Av. Pdte. Eduardo Frei M. 6001-71 Centro Empresas El Cortijo Conchali, Santiago, Chile www.rs-components.com