Engine Model: 4B3.9-G1 Engine Technical Data No. of Cylinders / Alignment: Cycle: 4 / In Line 4 Stroke Bore / Stroke: mm 102/120 Induction: Cooling Me

GKP 550KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

DIESEL GENERATOR SET DE165E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE220E0. Output Ratings. Technical Data. Image shown may not reflect actual package. Standby* Generator Set Model - 3 Phase

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

GKP 660KVA. GKP Series. Generator Set Specification. Ultra Silent, Extended Life!

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Image shown may not reflect actual package.

DIESEL GENERATOR SET DE110E2. Output Ratings. Technical Data. EU stage II emissions compliant. Generator Set Model - 3 Phase Prime* Standby*

EP series WPS100S-AU rpm,3-phase/5-wiring

WPS10S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

EP series WPS800S rpm,3-phase/5-wiring

WPS137S. EP Series. Generator Set Specification. Super Quiet, Superior Life! 广泛应用于通讯 工业 租赁. Widely applied in Telecom, Industry, Rental, 户外工程 矿山 军事等领域

WPS625 / WPS625S. Features: EP Series

EP series WPS150BS-AU rpm,3-phase/5-wiring

WPS1000 / WPS1000S. Features: EP Series

DIESEL GENERATOR SET. DE22E3 (B Series) Output Ratings. Technical Data

EC series GMS30CS-AU 50

WPS1250 / WPS1250S. Features: EP Series

TPD2250H6.3 TECHNICAL DATA

LSP88S3. Powered by 50HZ. Water-cooled. Three Phase. Diesel KVA 88 KW 70. Standby Power

PGPLS215Kw. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

WCS2000 / WCS2000S. Features: WCS Series

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

WPS100 / WPS100S. Features: EP Series

PGDLS352KW 380/ / / / / / / / /

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

DIESEL GENERATOR SET. 60 Hz FEATURES

PGPLS10. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PGPLS45. 60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps 240 ( )

WPS60 / WPS60S. Features: EP Series

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

50 HZ. l Outgoing cable stub-up area directly below circuit breaker. l Voltage regulation ±0.5 % l Provides fast recovery from transient load changes

AP59-6. Model Name AP59-6 Frequency / PF 60Hz, 1800 rpm, 0.8pf. Engine Make & Model Perkins 1103A-33TG1 Alternator Make Stamford

50 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

SIVASA Doosan Series. SD250 Technical Data

LSC500S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 500 KW 400. Standby Power

GMP80PX/ Features:

GMS1400C / GMS1400CS. Features: EC Series

GMS800C/ Features:

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

DIESEL GENERATOR SETS

PGDLS / / / / / / / / /

GMP400PX/ Features:

TECHNICAL DATA 50HZ MPMC POWERTECH CORP. DIESEL GENERATING SET MPS180S-1E / MPS180-1E

PGDLS200. Overall Dimensions (mm) & Weight (kg) Length:3900. Width:1140. Height: 1850

APD-ULJ250. Standby Power

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

60Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

LSC220S3. Powered by Cummins 50HZ. Water-cooled. Three Phase. Diesel KVA 220 KW 176. Standby Power

PGKT / / / / / / / / / / / /

PGCLS Hz/1800 r.p.m-p.f.0.8 Prime Power Standby Power Rated Current Genset Engine Alternator Voltage(V) PH kw/kva kw/kva Amps

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

2800 Series 2806A-E18TAG1A Diesel Engine ElectropaK

PGDLS / / / / / / / / /

DS100C6S. 2 Years or 2000 Hours Warranty. Power Your Dream! Enclosed structure, Small in size, High safety, Easy installation and operation

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

60 Hz FEATURES. Exclusively from your Caterpillar dealer

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

PRO Rental Product Range. PRO275-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Model NA 2 L

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

GMS100C / GMS100CS. Features: EC Series

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rating Definitions and Conditions

APD-ULM2000. Engine Alternator Voltage Standby Power Power Factor. PI734E (Wnd-312) 480 / 277V 2000kW A N.A.

60 Hz FEATURES. Exclusively from your Caterpillar dealer

Model MP150 W W

BC DIESEL GENERATORS TECHNICAL DATA DIESEL GENERATING SET 60HZ

ANG50P-6. Voltage Stand-by Power Stand-by Current Prime Power Prime Current. 480 / 277V 50kVA / 40kW 60.1 A 40kVA / 32kW 48.1 A

PRO Rental Product Range. PRO100-2 (EUIIIa Compliant) KEY FEATURES. Rental Ready Features. Alternator. Integrated Voltage Regulator (IVR) Enclosure

Rating Definitions and Conditions

Rating Definitions and Conditions

130 KW / 165 KVA POWERED by

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Rental Power QSB7 series engine

50 HZ 60 HZ. l Standard ambient temperatures up to 50 C (122 F) l Fan, fan drive and charging alternator fully guarded l Antifreeze protection coolant

APD-NG400. NG Standby Power

(1) Prime power: The rating is available for an unlimited of annual operating hours in variable load applications, in accordance with

Réf GB / e ALTERNATORS. LSA Pole. Electrical and mechanical data

GEH250 (3-Phase) 50 HZ. 230 kva / 184 kw FEATURES. Exclusively from your Caterpillar dealer

Super Silent, Superior Life!

Transcription:

Features: Rotate speed governor: Electronic Excitation system: self-excited, SHUNT A.V.R model: R250/R450 Emergency stop switch ATS (automatic transfer switch) receptacle 2x12V sealed for life maintenance free battery Lockable battery isolator switch Powder coated canopy (Only for Soundproofed sets) 50 radiator Oil pump on the engine Steel base frame with fork holes Vibration isolators between the engine/alternator and base frame Dry type air filter Base fuel tank for daily running Drain points for fuel tank Operation Manual / Specifications Model Length (L) Width (W) Height (H) Dry Weight kg WPS350 3520 1210 2150 3080 WPS350S 4450 1500 2200 4432 Notes: *** Dimensions and Weights *Prime Power Continuous duty operation, under variable load 24/24h-10% over load permissible 1 hour/12 hours; **Standby Power Standby duty, operation under variable load, without over load; Standard Reference Conditions Note: Standard reference conditions 25 C (77 F) Air Inlet Temp, 100m(328 ft) A.S.L. 30% relative humidity. Fuel consumption data at full load with diesel fuel with specific gravity of 0.85 and conforming to BS2869: 1998, Class A2. Output Ratings Generating Set Model Prime Power* Standby Power** WPS350 350kVA/280kW 385kVA/308kW WPS350S 350kVA/280kW 385kVA/308kW Ratings at 0.8 power factor Ratings and Performance Data Engine Make & Model: Alternator Brand: Alternator Model: Control System: Circuit Breaker Type: Frequency & Phase: Perkins 2206A-E13TAG2 Leroy somer LSA47.2VS1 Auto Gen Engine Speed: RPM 1500 Fuel Tank Capacity: litres WPS350 WPS350S Fuel Consumption: l/hr (100% ) Power -Standby Power 3 Pole MCCB 50Hz & 3PH 900 800 71 80 1/ 5

Engine model:2206a-e13tag2 Engine Technical Data No. of Cylinders / Alignment: Cycle: 6/Vertical in-line 4 Stroke Bore / Stroke: 130/157 Induction: Cooling Method: Governing Type: Governing Class: Turbocharged Water cooled Electronic ISO 8528 5 Class G2 Compression Ratio: 16.3:1 Displacement: 12.5L Moment of Inertia: kg m² 1.36 Engine Electrical System: - Voltage / Ground - Battery Charger Amps Weight: kg - Dry - Wet 24/Negative 24/70 1478 1582 Cooling System Cooling System Capacity: l 51.4 Capacity without Radiator: Energy to coolant and lubricating oil: kwt Energy to Radiation: kw 24.1 32.2 113.5 128.5 Energy to cooling fan: kwm 14 Radiator Cooling Airflow: m³/min External Restriction to Cooling Airflow: Pa Designed to operate in ambient conditions up to 50 C (122 F). Contact your local PowerLink Dealer for power ratings at specific site conditions Performance Engine Speed: rpm 1500 Gross Engine Power: kw 368.4 412.5 BMEP: kpa 2344 2637 Lubrication System Oil Filter Type: Spin-On, Full Flow Total Oil Capacity: l 40 Minimum: l 32.5 Oil Type: API-CH-SAE15W-40 Fuel System Fuel Filter Type: Replaceable Element Recoended Fuel: Diesel Class A2 Fuel Consumption: l/hr Prime 110% 100% 75% WPS350 77 71 54 37 WPS350S 77 71 54 37 (Based on diesel fuel with a specific gravity of 0.85 and conforming to BS2869,Class A2) 50% Oil Cooling Method: Water-cooled Exhaust System Air Systems Silencer Type: Industrial Air Filter Type: Paper Element Exhaust Outlet Size: 123 Silencer Noise Reduction Level: Maximum Allowable Back Pressure: kpa Combustion Air Flow: m³/min 21.3 23.6 Exhaust Gas Flow: m³/min 56.6 64.8 Max. Air Intake Restriction: kpa -clean filter -dirty filter 2.5 6.4 Exhaust Gas Temperature: C 630 630 The weights are approximate and without fuel. 2/ 5

Alternator model: LSA47.2VS1 Alternator Physical Data Manufactured for FG Wilson by: Leroy somer Model: LSA47.2VS1 No. of Bearings: Single Insulation Class: H Winding Pitch Code: 2/3 Wires: 12 Ingress Protection Rating: IP23 Excitation System: SHUNT, AREP or PMG AVR Model: R250, R450 Alternator Operating Data Overspeed: rpm 2250min 1 Voltage Regulation: (Steady state) ±0.5% Wave Form NEMA = TIF: <50 Wave Form IEC = THF: <2% Total Harmonic content LL/LN: No load <1.5% on load <2% Radio Interference: Radiant Heat: kw (Btu/min) -WPS350 -WPS350S Alternator WPS350 WPS350S Performance Data: Data Item Motor Starting Capability* kva Short Circuit Ratio** % Reactances: Per Unit Xd X'd X"d Voltage Technical Data WPS350 Voltage Prime: Standby: kva kw kva kw Voltage Technical Data WPS350S Voltage Prime: Standby: kva kw kva kw 3/ 5

Control System PLC-7420 FEATURES Microprocessor control, with high stability and credibility. Mains supply and generator operation monitoring. Indicating operation status and fault conditions. Multiple protections; multiple parameters display, such as pressure, temperature. Manual and automatic work mode selectable. Real time clock for time and date display, overall runtime display, 99 log entries. Overall power output display. Integral speed/frequency detecting, telling status of start, rated operation, overspeed. Counication with PC via RS485 or RS232 interface, using MODBUS protocol. Engine ECU is available. Coon USB cable is usable for parameter configuration. Multi-language is available. PLC-920 (Optional) FEATURES Parameter configuration via RS-232 serial counication; Log last 50 events & alarm information with measured values; Statistics records; Remote start/stop; Speed sensing from alternator voltage or magnetic pickup; Configurable 3 inputs and 6 outputs; ECU powers, ECU stop, STOP or fuel solenoid selection; Automatic transfer switching control and engine control; Adjustable start, load and stop timers. 4/ 5

Optional Engine Alternator Generator Set Fuel System Canopy Water Jacket Preheater Oil Preheater Winding Temperature Measuring Instrument Alternator Preheater PMG Anti-damp and anti-corrosion treatment Anti-condensation heater Tools with the machine Low fuel level alarm Automatic fuel feeding system Fuel T-valves Trailer Lubricating System Exhaust System Cooling System Control System Voltages Oil with the machine Protection board from hotness Front heat protection Coolant (-30 C) Remote control panel PLC-920 ATS 415/240V 400/230V 380/220V 220/127V 200-115V The following lists are optional by the needs of customers. Minor Repair / 1000 hrs optional No. Part Name Part No. Qty Remark 1 Fuel Filter CH10931 6 2 Pre fuel filter CH10930 6 3 Oil Filter CH10929 6 4 Air Filter CH11217 5 5 BELT CH12032 1 6 ALT belt CH11037 1 7 SEAL ROCKER BOX COVER CH12142 1 8 GASKET CYLINDER HEAD CH12454 1 9 THERMOSTAT CH11620 2 10 FRONT OIL SEAL CH12442 1 11 SEAL REAR END OIL CH12721 1 If you have any question or inquiry, please contact PowerLink sales organization or contact: info@powerlinkworld.com Local Distributor Specification may change without prior notice. For more info, please contact PowerLink or your local distributors. /2013 1 st Edition 5/ 5