GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Standard Features

Similar documents
Introduction. Standard Features. GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Introduction

3 - Protection components Motor circuit-breakers

Short-Circuit Current Ratings

TeSys GV2 - GV3 Manual Starters and Protectors

Protection components

TeSys contactors. Use in category DC-1 (resistive loads; time constant L/R y 1 ms) Rated operational current Ie. to be wired in series

TeSys contactors 5. Characteristics 5. Mini-contactors TeSys LC1 SK and LP1 SK. Environment Rated insulation voltage (Ui) 5/30

Technical data for manual motor starters Type MS325

Page. Circuit-Breakers M4 2 for motor protection. Auxiliary contacts 3 Signalling switch Auxiliary releases

cor Long Run Experience

FMotor Circuit Controllers

GJL 100 A Molded Case Circuit Breaker GJL 75 A Motor Circuit Protector

AF40... AF96 3-pole contactors Technical data

KT4 Manual Motor Starter

MS /27/2015. ABB contact for United States of America. General Information Extended Product Type: Categories

Motor starters up to 150 A

Ideal for use as a manual starter

Circuit-Breakers M4 166 for motor protection. Auxiliary contacts 167 Signalling switch Auxiliary releases

AF09... AF30 3-pole Contactors up to 25 HP / 600 VAC

Contactors. Mini-contactors type LC1-SKGC for use in modular panels. Conforming to standards IEC/EN , IEC/EN , NF C , VDE 0660

MS General Information Extended Product Type: MS

Vistop TM isolating switches 63 to 160A

Modular contactors and relays

Index. Manual Motor Starters 1. Auxiliary Contact Blocks 1. Trip Alarm Auxiliary 1. Switch. Shunt Release 1. Under-voltage Release 2.

Essential equipment for all your requirements

Product index. 4 - Manual motor protectors. Manual motor protectors. Manual motor protectors Low Voltage Products & Systems 4.

Manual Motor Starters. Meta-MEC

Characteristics TeSys contactors 0 TeSys k contactors and reversing contactors

Motor circuit-breakers TeSys GV2, GV3 and GV7. Catalogue July

I r A short-circuit protective device: Observe the maximum permissible fuse of the contactor with direct device mounting.

Industrial Contactors CTX 3 3P 185A - 800A

MULTI 9 System Catalog IEC Rated C60N/H/L Circuit Breakers

AF40... AF96 3-pole contactors 30 to 60 hp at 480 V AC AC / DC operated with 1 N.O. + 1 N.C. auxiliary contacts

Protection Equipment

3VU13, 3VU16 Circuit-Breakers

AF series contactors (9 2650)

Product index. 4 - Manual motor protectors. Phone: Fax: Web: -

Technical Information

CI-TI Contactors and motor starters Types CI 61 - CI 98

DPX moulded case circuit breakers

DNX 3 MCB 4500 A / 6 ka Phase + Neutral, neutral on left side

Siemens AG Price groups PG 14O, 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J

, , PREPARATION - CONNECTION. Mounting:. On symmetrical EN rail or DIN 35 rail

Phase + Neutral, neutral on left side

Features 1 Phase HP/Volts 1/6 HP AT 230 V 3 Phase HP/Volts 1/2 HP AT 200/230 V, 1-1/2 HP AT 460/575 V

Thermal overload relays Type TA Class 10

Data sheet. CI-TI TM Contactors and Motor Starters Circuit Breakers CTI B1427

Phone: Fax: Web: -

TeSys Enclosed Starters. Let TeSys ensure safety in your simple motor applications

C -5 to +55 (0.8 to 1.1Uc) Permissible o

Series KTU7 UL489 Molded Case Circuit Breakers

Micro Contactor MA Series

AF series contactors (9 2650)

Phase + Neutral, neutral on right side

TeSys Motor Starter Solutions for the North American Market

DATASHEET - ZB Delivery program. Overload relay, 50-65A, 1N/O+1N/C. Catalog No Eaton Catalog No. XTOB065DC1 EL-Nummer

AF09... AF38 4-pole Contactors AC / DC Operated - with Screw Terminals

KT4 Manual Motor Starters

DX³ 4-pole RCBO 6000 A/10 ka

LR9 F OVERLOAD RELAYS

Bulletin 193-T1 Bimetallic Overload Relays

B115...B180 RF200 RFN200 B250...B400 RF400 RFN400

Approved Standards. Ordering Information. Mini Motor Contactor J7KNA. Model Number Legend. Main contactor. Accessories. Mini Motor Contactor J7KNA 1

Manual Motor Starters

Series KTU7 UL489 Molded Case Circuit Breakers

4 - Miniature controls

Protection Equipment. 5/2 Introduction

Multistandard offer for OEM applications. Single solution source for business without borders

SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 40 A Accessories Enclosures and front plates

Description. Positive safety relays

AF / AF12Z pole Contactors AC / DC Operated - with Screw Terminals

D509E. Manual Motor - Starters

Short form catalogue. Motor protection & control

MS25, MST25, MS20, MST20

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Protectors. 35mm DIN rail snap-on mounting. Wide range of accessories

Motor-protectivecircuit-breaker,3p,Ir=2.5-4A. Product range PKZM01 motor protective circuit-breakers up to 16 A with pushbutton actuation

XT IEC Power Control Manual Motor Protectors

Motor Protection Circuit Breaker

CTX 3 Control relays Cat. N (s) : /06/09..14/16/19..24/26/29

Manual motor protectors Type MS116 Type MS325 Type MS45X Type MS49X

Meta Solution. Contactors and Overload relays

Interchangeable Built-in Fixed thermal Adjustable thermal Magnetic Fixed Adjustable Adjustable Electronic RMS 7 LS LSI

DPX Thermal magnetic and trip-free switches DPX 3 -I 250

DPX Thermal magnetic and trip-free switches DPX 3 -I 630

Approvals UL 508; CSA-C22.2 No ; IEC/EN ; CE marking

TeSys D Overload Relays

PKZ and PKE motor-protective circuit-breakers

INTEGRAL Self-Protected Combination Motor Controllers

B6, B7, BC6, BC7, TBC7 3- and 4-pole mini contactors VB6, VB7, VBC6, VBC7 3- and 4-pole mini reversing contactors Technical data

Control Circuit Protection

DPX 630 Electronic release

Approbationen IEC/EN ; UL 508; CSA-C22.2 No ; CE marking

Product range Overload relay ZB up to 150 A. Phase-failure sensitivity IEC/EN 60947, VDE 0660 Part 102

FUSOMAT Visible breaking and tripping fuse switches from 250 to 1250 A

AF09... AF30 3-pole Contactors up to 20 HP / 480 VAC

3RV1011-0DA15 CIRCUIT-BREAKER, SIZE S00,

AE 9... AE 40 Contactors NE... Contactor Relays

References 4 Fuse carriers

DPX 1600 Electronic release

Transcription:

Standard Features Table : Standard Features GV2ME GV2P GV3P GV7RE/GV7RS 0. to 32 A Up to 20 hp @ 460 V 0 SCCR @ 480 V Push Button Operator 0. to 30 A Up to 5 hp @ 460 V 50 SCCR @ 480 V Rotary Handle Operator Visible Trip Indication 9 to 65 A Up to 40 hp @ 460 V GV3P3 GV3P32 rated 00 SCCR @ 480 V GV3P40 GV3P65 rated 65 SCCR @ 480 V Rotary Handle 25 to 220 A Up to 50 hp @ 460 V 25 SCCR @ 480 V Toggle Operator Protection Thermal-magnetic (overload relays are bimetallic Class 0) Solid-state overload relay magnetic short circuit (Class 0) Mounting Clip-on mounting on 35 mm DIN rail. Unclips without the use of a tool. Panel mounts using a metal adapter plate. Connection Clip-on mounting on 35 mm DIN rail. Unclips without the use of a tool. Panel mounts directly. Screw terminals using cross-head, captive screws. Cross-head screws used for connections on GV2 starters and their add-on blocks. Clip-on mounting on 35 mm DIN rail. Unclips without the use of a tool. Panel mounts directly. Uses an Allen wrench. Marking Using the marker holder supplied with each unit. Trip test Using a fine-blade screwdriver on the front face of the product. Signaling on the front face Manual control device Mechanical flag indicator Padlocking Tamper-proof current dial Accessories Front-mounting accessories Side-mounting accessories (snap onto the starters without the use of a tool) Other accessories On or Off state On or Off state Trip on overload, short circuit, undervoltage, or shunt trip. On or Off state Trip on overload, short circuit, undervoltage, or shunt trip. Panel mounts directly Clip-on connectors (sold separately) On or Off state Trips on short circuit Trips on short circuit Trip on overload or short circuit Padlocks in the Off position using the system incorporated into the manual control device. (Padlocks are supplied by the customer.) The thermal-current setting dial is covered by a transparent cover, which can be sealed. Instantaneous contact blocks either N.C.,, +, or + N.C. which do not increase the width of the product. On the left side, contact blocks which provide the following: + or + N.C. instantaneous contacts or N.C. trip signaling contact incorporating a mechanical flag indicator and an or N.C. instantaneous contact C/O magnetic trip signaling contact, associated with a mechanical flag indicator, used for reset. On the right side: Shunt trip or undervoltage trip Combination block for use with TeSys contactor Bus bars and connectors Visible isolation block, mounting on the incoming terminals of the device Door interlock mechanism Selection Page 38 Page 38 Page 38 Page 39 Padlockable when used with a door-mounted rotary handle or with a separate locking device Front accessible, internally mounted: Auxiliary contacts Trip indication contacts Shunt trip Undervoltage trip Rotary Handles 6

Short-Circuit Current Ratings GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors Short-Circuit Current Ratings UL 508 Type E Manual Self-Protected Combination Motor Controller, TeSys GV Manual Self-Protected Combination Starter Meeting UL 508 Type E, UL File E6487 Table 2: TeSys GV2P Horsepower and SCCR Ratings In combination with line spacer GV2GH7 (stand-alone starters) or GVG09 terminal and GV2G busbars (multiple starters) Standard Motor Ratings @ 50/60 Hz (hp) Ø 3 Ø 20 V 240 V 200 V 240 V 480 V 600 V Associated Cable, AWG 75 C, Cu Manual Self-Protected Starter Overload Trip Range (A) 0 GV2P0 0. 0.6 00 0 GV2P02 0.6 0.25 00 0 GV2P03 0.25 0.4 00 0 GV2P04 0.4 0.63 00 0.5 0 GV2P05 0.63 00 0.75 0 GV2P06.6 00 0.5 0.5 0 GV2P07.6 2.5 00 0.75 2 0 GV2P08 2.5 4 00.5.5 4 0 GV2P0 4 6.3 00 0.5 2 3 5 7.5 0 GV2P4 6 0 00 2 3 3 0 0 8 GV2P6 9 4 0 3 5 5 0 5 8 GV2P20 3 8 0 2 3 5 7.5 5 20 6 GV2P2 7 23 0 2 3 5 7.5 5 20 6 GV2P22 20 25 0 SCCR () 480Y/277V Table 3: TeSys GV3P Horsepower and SCCR Ratings In combination with line spacer GV3G66 and magnetic trip unit GVAM for stand-alone starters Standard Motor Ratings @ 50/60 Hz (hp) Ø 3 Ø 20 V 240 V 200 V 240 V 480 V 600 V Associated Cable, AWG 75 C, Cu Manual Self-Protected Starter Overload Trip Range (A) SCCR () 480Y/277 V 600Y/347 V 2 3 3 7.5 0 8 GV3P3 9 3 00 25 3 3 5 7.5 0 8 GV3P8 2 8 00 25 2 3 5 7.5 5 20 6 GV3P25 7 25 00 25 2 3 7.5 7.5 20 25 6 GV3P32 23 32 00 25 3 5 0 0 25 30 3 GV3P40 30 40 65 25 3 7.5 0 0 30 40 3 GV3P50 37 50 65 25 5 0 5 5 40 50 3 GV3P65 48 65 65 25 7

Short-Circuit Current Ratings UL 508 Type F Combination Motor Controller, TeSys GV Manual Self-Protected Combination Starter Meeting UL 508 Type F, UL File E6487 Table 4: TeSys GV2P Horsepower and SCCR Ratings In combination with line spacer GV2GH7 (stand-alone starters) or GVG09 terminal and GV2G busbars (multiple starters) Standard Motor Ratings @ 50/60 Hz (hp) Ø 3 Ø 20 V 240 V 200 V 240 V 480 V 600 V Associated Cable, AWG 75 C, Cu Manual Self-Protected Starter Overload Trip Range (A) Type of Contactor Required 0 GV2P0 0. 0.6 00 0 GV2P02 0.6 0.25 00 0 GV2P03 0.25 0.4 00 0 GV2P04 0.4 0.63 00 0.5 0 GV2P05 0.63 00 0.75 0 GV2P06.6 00 0.5 0.5 0 GV2P07.6 2.5 00 0.75 2 0 GV2P08 2.5 4 00.5.5 4 0 GV2P0 4 6.3 00 0.5 2 3 5 7.5 0 GV2P4 6 0 00 2 3 3 0 0 8 GV2P6 9 4 LC or D8 3 5 5 0 5 8 GV2P20 3 8 LC or D8 2 3 5 7.5 5 20 6 GV2P2 7 23 LCD25 or D32 2 3 5 7.5 5 20 6 GV2P22 20 25 LCD25 or D32 SCCR () 480Y/277 V Table 5: TeSys GV3P Horsepower and SCCR Ratings In combination with line spacer GV3G66 and magnetic trip unit GVAM for stand-alone starters Standard Motor Ratings @ 50/60 Hz (hp) Ø 3 Ø 20 V 240 V 200 V 240 V 480 V 600 V Associated Cable, AWG 75 C, Cu Manual Self-Protected Starter Overload Trip Range (A) Type of Contactor Required SCCR () 480Y/ 277 V 2 3 3 7.5 0 8 GV3P3 9 3 LCD8 65 25 3 3 5 7.5 0 8 GV3P8 2 8 LCD8 65 25 2 3 5 7.5 5 20 6 GV3P25 7 25 LCD25 65 25 2 3 7.5 7.5 20 25 6 GV3P32 23 32 LCD32 65 25 3 5 0 0 25 30 3 GV3P40 30 40 LCD40A/ 50A/65A 65 25 3 7.5 0 0 30 40 3 GV3P50 37 50 LCD50A/65A 65 25 5 0 5 5 40 50 3 GV3P65 48 65 LCD65A/80 65 25 600Y/ 347 V 8

Short-Circuit Current Ratings UL 508 Group Motor Installations Manual Combination Motor Controller, TeSys GV GV2ME: UL File E64864 (MC 6458, Report 02350, Project 252063) Table 6: TeSys GV2ME Horsepower and SCCR Ratings In association with LCD contactors, suitable for group installation when protected by fuses or an inverse-time circuit breaker (when used with GVG09 terminal or GV2G05 blocks plus GV2G busbars) Standard Motor Ratings @ 50/60 Hz (hp) Ø 3 Ø 20 V 240 V 200 V 240 V 480 V 600 V Associated Cable, AWG 75 C, Cu Manual Motor Starter Overload Trip Range (A) Contactor 240/ 480 V 600Y/ 347 V SCCR () 480 V with GVL3 Limiter Contactor 600 V with LA9LB920 Limiter 0 GV2ME0 0. 0.6 65 65 0 GV2ME02 0.6 0.25 65 65 0 GV2ME03 0.25 0.4 65 65 0 GV2ME04 0.4 0.63 65 65 0.5 0 GV2ME05 0.63 65 65 0.75 0 GV2ME06.6 65 65 0.5 0.5 0 GV2ME07.6 2.5 65 65 0.75 2 0 GV2ME08 2.5 4 65 65.5.5 4 0 GV2ME0 4 6.3 65 65 0.5 2 3 5 7.5 0 GV2ME4 6 0 65 65 2 3 3 0 0 8 GV2ME6 9 4 LC or D8 22 0 65 LCD32 or D38 3 5 5 0 5 8 GV2ME20 3 8 LC or D8 22 0 65 LCD32 or D38 2 3 5 7.5 5 20 6 GV2ME2 7 23 LCD25 or D32 0 0 65 LCD32 or D38 2 3 5 7.5 5 20 6 GV2ME22 20 25 LCD25 or D32 0 0 65 LCD32 or D38 2 5 0 0 20 30 6 GV2ME32 24 32 LCD25 or D32 5 5 65 LCD32 or D38 9

GV2 Specifications Table 7: Environment Type GV2ME GV2P LSD30, LSD303 Conforming to standards Product approvals UL File Number IEC 60947-, 60947-2, 60947-4-, EN 60204, BS 4752, BS 494, UL 508, CSA C22.2 No. 4, NF C 63-650, NFC63-20, 79-30, VDE 03, 0660. DEMKO, NEMKO, SEMKO, CSA. UL, CSA, UL, PTB UL, CSA BV BV, GL, LROS, DNV, PTB File E64864, CCN NLRV File E9764 CCN IZLT CSA File Number File LR 8630, Class 32 05 File 222370, Class 6225-0 Protective treatment TH TH LSD32, LSD323 File E9764 CCN IZLT2 Degree of protection Conforming to IEC 60529 GV2ME0 enclosure: IP4 GV2ME02 enclosure: IP55 Shock resistance Conforming to IEC 60068-2-27 Vibration resistance Conforming to IEC 60068-2-6 30 g 30 g 5 to 50 Hz (5 g) 5 to 50 Hz (5 g) Ambient air temperature Storage -40 to +76 F (-40 to +80 C) -40 to +76 F (-40 to +80 C) Operation Temperature compensation Flame resistance Conforming to IEC 60695-2- Open: -4 to +40 F (-20 to +60 C) Enclosed: -4 to 04 F (-20 to 40 C) Open: -4 to +40 F (-20 to +60 C) Enclosed: -4 to 04 F (-20 to 40 C) 760 F (960 C) -4 to +40 F (-20 to +60 C) -58 to +58 F (-50 to +70 C) -4 to +40 F (-20 to +60 C) -58 to +58 F (-50 to +70 C) Maximum operating altitude 6562 ft (2000 m) 6562 ft (2000 m) Operating positions in relation to the normal vertical mounting position 90 90 90 90 30 30 90 90 ± 23 Wiring Number of conductors and wire size Maximum Minimum Maximum Minimum Maximum Minimum Solid cable 2 x 8 AWG (2 x 6 mm 2 ) 2 x 6 AWG (2 x mm 2 ) 2 x 8 AWG (2 x 6 mm 2 ) 2 x 6 AWG (2 x mm 2 ) 2 x 8 AWG (2 x 6 mm 2 ) 2 x 6 AWG (2 x mm 2 ) Flexible cable without cable end 2 x 8 AWG (2 x 6 mm 2 ) 2 x 4 AWG (2 x mm 2 ) 2 x 8 AWG (2 x 6 mm 2 ) 2 x 4 AWG (2 x mm 2 ) 2 x 8 AWG (2 x 6 mm 2 ) 2 x 4 AWG (2 x mm 2 ) Flexible cable with cable end 2 x 0 AWG (2 x 4 mm 2 ) 2 x 6 AWG (2 x mm 2 ) 2 x 0 AWG (2 x 4 mm 2 ) 2 x 6 AWG (2 x mm 2 ) 2 x 0 AWG (2 x 4 mm 2 ) 2 x 6 AWG (2 x mm 2 ) Suitable for isolation Conforming to IEC 60947- / 60947--6 Tightening torque Resistance to mechanical impact Yes Yes 5 lb-in (.7 N m) 0.5 J 0.5 J Sensitivity to phase failure Conforming to IEC 60947-4-, paragraph 7-2--5-2 0

Table 8: Technical Characteristics Type GV2ME GV2P LSD30, LSD303 Utilization category Conforming to IEC 60947-2 A A Conforming to IEC 60947-4- AC-3 AC-3 LSD32, LSD323 [] AC 20B# Rated operational voltage (Ue) Conforming to IEC 60947-2 690 V 690 V 690 V 690 V Rated insulation voltage (Ui) Conforming to IEC 60947-2 690 V 690 V Conforming to CSA C22.2 No. 4 and UL 508 600 V 600 V 690 V Rated operational frequency Conforming to IEC 60947-2 50/60 Hz 50/60 Hz 50/60 Hz 50/60 Hz Rated impulse withstand voltage (U imp) Conforming to IEC 60947-2 6 kv 6 kv Total power dissipated per pole (W) 2.5 W 2.5 W 3.2 W 3.2 W Mechanical life (close-open operations) (varies with conditions) Electrical life (close-open operations) (for AC-3 duty) Duty class (close-open operations/hr) (maximum operating rate) 00,000 00,000 00,000 25 25 Rated duty Conforming to IEC 60947-4- Conforming to IEC 60947-3 Continuous duty Table 9: GV2 Trip Module Specifications Type GV2AU GV2AS Rated insulation voltage (Ui) Conforming to IEC 60947-690 V 690 V Operational voltage (Ue) Conforming to IEC 60947-0.85-. V 0.7-. V Drop-out voltage (Ue) 0.35-0.7 V 0.2-0.75 V Inrush consumption Sealed consumption Operating time (ms) Conforming to IEC 60947-2 VA 4 VA 8 W 0.5 W 3.5 VA 5 VA. W.6 W From the moment the voltage reaches its operational value until opening of the GV2 0 5 ms On-load factor 00% Wiring Minimum Maximum Number of conductors and wire size Solid cable x 6 2 AWG (-2.5 mm 2 ) 2 x 6 2 AWG ( 2.5 mm 2 ) Flexible cable without cable end x 8 2 AWG (0.75-2.5 mm 2 ) 2 x 8 2 AWG (0.75 2.5 mm 2 ) Flexible cable with cable end x 8 4 AWG (0.75-.5 mm 2 ) 2 x 8 4 AWG (0.75.5 mm 2 ) Tightening torque 2 lb-in (.4 N m) maximum

Table 0: Type GV Auxiliary and Fault Signaling Contact Specifications Instantaneous Auxiliary Contacts GVAN, GVAD Fault Signaling Contacts GV2AD, GV2AM Rated insulation voltage (Ui) (associated insulation coordination) Conforming to IEC 60947- Conforming to CSA C22.2 No. 4 and UL 508 Conventional rated thermal current (Ith) Conforming to IEC 60947-5- Conforming to CSA C22.2 No. 4 and UL 508 Operational power and current AC operation Conforming to IEC 60947-5- Rated operational voltage (Ue) 690 V 690 V 600 V 300 V 6 A 2.5 A 5 A A AC-5/00,000 close open operations 48 V 0 V 27 V 230 V 240 V 380 V 45 V 440 V 500 V 690 V 24 V 48 V AC-4/000 close open operations Operational power, normal conditions 300 VA 500 VA 720 VA 850 VA 650 VA 500 VA 400 VA 36 VA 48 VA 72 VA 72 VA Occasional breaking and making capacities, abnormal conditions 3000 VA 7000 VA 3,000 VA 5,000 VA 3,000 VA 2,000 VA 9000 VA 220 VA 300 VA 450 VA 450 VA Rated operational current (Ie) 6 A 4.5 A 3.3 A 2.2 A.5 A A 0.6 A.5 A A 0.5 A 0.3 A Operational power and current DC operation Conforming to IEC 60947-5- DC-3/00,000 close open operations DC-3/000 close open operations Rated operational voltage (Ue) 24 V 48 V 60 V 0 V 240 V [] 24 V 48 V 60 V Operational power, normal conditions 40 W 240 W 80 W 40 W 20 W 24 W 5 W 9 W Occasional breaking and making capacities, abnormal conditions 240 W 360 W 240 W 20 W 80 W 00 W 50 W 50 W Rated operational current (Ie) 6 A 5 A 3 A.3 A 0.5 A A 0.3 A 0.5 A Low-level switching contact reliability Number of faults for n million operating cycles (7 V, 5 ma): = 0-6 Short-circuit protection Wiring (screw clamp) Number of conductors and wire size Add an RC circuit, Type LA4D, to the load terminals. Consult the Digest. GB2CB control circuit protector or control circuit fuse gg 0 A maximum (or equivalent). Minimum Maximum Solid cable x 6 2 AWG ( 2.5 mm 2 ) 2 x 6 2 AWG ( 2.5 mm 2 ) Flexible cable without cable end x 8 2 AWG (0.75 2.5 mm 2 ) 2 x 8 2 AWG (0.75 2.5 mm 2 ) Flexible cable with cable end x 8 4 AWG (0.75.5 mm 2 ) 2 x 8 4 AWG (0.75.5 mm 2 ) Wiring (spring terminal) Minimum (GVAN only) Maximum (GVAN only) Flexible cable without cable end x 8 2 AWG (0.75 2.5 mm 2 ) 2 x 8 2 AWG (0.75 2.5 mm 2 ) Tightening torque 2 lb-in (.4 N m) maximum 0 V 27 V 230 V 240 V 2

Table : Type GV2AE Auxiliary Contact Specifications Instantaneous Auxiliary Contacts GV2AE Rated insulation voltage (Ui) (associated insulation coordination) Conforming to IEC 60947- Conforming to CSA C22.2 No. 4 and UL 508 Conventional rated thermal current (Ith) Conforming to IEC 60947-5- Conforming to CSA C22.2 No. 4 and UL 508 Operational power and current AC operation Conforming to IEC 60947-5- 250 V (690 V with respect to main circuit) 300 V 2.5 A A AC-5/00,000 close open operations Rated operational voltage (Ue) 24 V 48 V 0 V 27 V 230 V 240 V Operational power, normal conditions 48 VA 60 VA 20 VA 20 VA Occasional breaking and making capacities, abnormal conditions 480 VA 600 VA 270 VA 2400 VA Rated operational current (Ie) 2 A.25 A A 0.5 A Operational power and current DC operation DC-3/00,000 close open operations Conforming to IEC 60947-5- Rated operational voltage (Ue) 24 V 48 V 60 V Operational power, normal conditions 24 W 5 W 9 W Occasional breaking and making capacities, abnormal conditions 00 W 50 W 50 W Rated operational current (Ie) A 0.3 A 0.5 A Low-level switching contact reliability Number of faults for n million operating cycles (7 V, 5 ma): = 0-6 Short-circuit protection GB2CB control circuit protector or control circuit fuse gg 0 A maximum (or equivalent). Wiring (screw clamp) Number of conductors and wire size Minimum Maximum Solid cable x 6 2 AWG ( 2.5 mm 2 ) 2 x 6 2 AWG ( 2.5 mm 2 ) Flexible cable without cable end x 8 2 AWG (0.75 2.5 mm 2 ) 2 x 8 2 AWG (0.75 2.5 mm 2 ) Flexible cable with cable end x 8 4 AWG (0.75.5 mm 2 ) 2 x 8 4 AWG (0.75.5 mm 2 ) Wiring (spring terminal) Minimum (GVAN only) Maximum Flexible cable without cable end x 8 2 AWG (0.75 2.5 mm 2 ) 2 x 8 2 AWG (0.75 2.5 mm 2 ) Tightening torque 2 lb-in (.4 N m) maximum Contact operation instantaneous auxiliary contacts GVAN20 GVAN GVAE GVAE20 GVAE 0 Power Pole GVAD 0 N.C. N.C. N.C. GVAD 0 N.C. Contact Open Contact Closed Operation of fault signaling contacts GV2AM Change of state following trip on short circuit. GV2AD0 and AD0 Change of state following trip on short circuit, overload or undervoltage. 3

Table 2: GV2 Accessory Specifications 3-Pole Busbars GV2G Rated insulation voltage (Ui) Conforming to IEC 60947-690 V Conventional rated thermal current (Ith) Conforming to IEC 60439-63 A Permissible peak current (I peak) Permissible thermal limit (I 2 t) 04 2 s Degree of protection Conforming to IEC 60529 IP20 Terminal Blocks GV2G05 and GVG09 Rated insulation voltage (Ui) Conforming to IEC 60947-690 V Conventional rated thermal current (Ith) Conforming to IEC 60439-63 A Degree of protection Conforming to IEC 60529 IP20 Wiring Tightening torque Solid cable Flexible cable without cable end Flexible cable with cable end Connector Screw clamp Current Limiter GVL3 (European applications only) x 4 2 AWG (.5 25 mm 2 ) conductor or 2 x 4 6 AWG (.5 0 mm 2 ) conductors x 4 2 AWG (.5 25 mm 2 ) conductor or 2 x 2 6 AWG (2.5 0 mm 2 ) conductors x 4 4 AWG (.5 6 mm 2 ) conductor or 2 x 4 0 AWG (.5 4 mm 2 ) conductors 20 lb-in (2.2 N m) 5 lb-in (.7 N m) Rated insulation voltage (Ui) Conforming to IEC 60947-690 V Conventional rated thermal current (Ith) Conforming to IEC 60947-63 A Operating threshold rms current 500 A (non adjustable threshold) Wiring Tightening torque Solid cable Flexible cable without cable end Flexible cable with cable end x 4 2 AWG (.5 25 mm 2 ) conductor or 2 x 4 6 AWG (.5 0 mm 2 ) conductors x 4 2 AWG (.5 25 mm 2 ) conductor or 2 x 2 6 AWG (2.5 0 mm 2 ) conductors x 4 4 AWG (.5 6 mm 2 ) conductor or 2 x 4 0 AWG (.5 4 mm 2 ) conductors 20 lb-in (2.2 N m) 4

GV2 Operating Curves Table 3: Thermal-Magnetic Trip Curves for GV2ME and GV2P Average operating time at 68 F (20 C) as a function of multiples of the setting current Time (s) 0,000 000 00 0 2 3 0. 0.0 0.00.5 0 00. 3 poles from cold state 2. 2 poles from cold state 3. 3 poles from hot state x setting current (lr) 5

Table 4: Current Limitation on Short Circuit For GV2M and GV2P 3Ø, 400/45 V Dynamic stress peak = f (prospective Isc) at.05 Ue = 435 V Maximum peak current (A) 00,000 = 0.25 = 0.3 2 0,000 = 0.8 = 0.7 = 0.5 3 4 5 6 7 000 cos ϕ = 0.95 = 0.9 8 9 0 00 00 000 0,000 5,000 () 00,000 Prospective Isc (A). I peak maximum 7. 4 6.3 A 2. 20 25 A 8. 2.5 4 A 3. 7 23 A 9..6 2.5 A 4. 3 8 A 0..6 A 5. 9 4 A. Limit of rated ultimate breaking capacity on short circuit of 6. 6 0 A GV2M (4, 8, 23, and 25 A ratings) 6

Table 5: Thermal Limit on Short Circuit for GV2ME Thermal limit in 2 s in the magnetic operating zone Sum of l 2 dt = f (prospective Isc) at.05 Ue = 435 V 2 2 Sum of I dt ( s) 00 2 3 4 5 6 7 0 8 9 0 0. 0.0 0. 0 00 Prospective Isc (). 24 32 A 6. 6 0 A 2. 20 25 A 7. 4 6.3 A 3. 7 23 A 8. 2.5 4 A 4. 3 8 A 9..6 2.5 A 5. 9 4 A 0..6 A 7

Table 6: Thermal Limit on Short Circuit for GV2P Thermal limit in 2 s in the magnetic operating zone Sum of I 2 dt = f (prospective Isc) at.05 Ue = 435 V 2 2 Sum of I dt ( s) 00 2 3 4 5 6 0 7 8 9 0. 0.0 0. 0 00 Prospective Isc (). 24 32 A 6. 6 0 A 2. 20 25 A 7. 4 6.3 A 3. 7 23 A 8. 2.5 4 A 4. 3 8 A 9..6 2.5 A 5. 9 4 A 0..6 A 8

Table 7: GV2ME Breaking Capacity for European Applications Type Rating [] Breaking capacity conforming to IEC 60947-2 Associated fuses (if required) if Isc > breaking capacity Icu conforming to IEC 60947-2 Ics = % of Icu. 230/240 V 400/45 V 440 V 500 V 690 V 230/240 V 400/45 V 440 V 500 V 690 V Catalog Number Suffix (GV2ME) Units 0 06 07 08 0 4 6 20 2 22 A 0..6 2.5 4 6.3 0 4 8 23 25 50 50 % 00 00 5 5 5 5 % 50 50 40 40 50 5 8 8 6 6 Icu % 00 00 50 50 50 50 50 0 6 6 4 4 % 00 00 75 75 75 75 3 3 3 3 3 3 3 3 % 75 75 75 75 75 75 75 75 am 80 80 gl 00 00 am 63 63 80 80 gl 80 80 00 00 am 50 50 50 50 63 63 A gl 63 63 63 63 80 80 am 50 50 50 50 50 50 gl 63 63 63 63 63 63 am 6 25 32 32 40 40 40 40 gl 20 32 40 40 50 50 50 50 Table 8: GV2P Breaking Capacity for European Applications Type Rating [] Breaking capacity conforming to IEC 60947-2 Associated fuses (if required) if Isc > breaking capacity Icu conforming to IEC 60947-2 Ics = % of Icu. 230/240 V 400/45 V 440 V 500 V 690 V 230/240 V 400/45 V 440 V 500 V 690 V Catalog Number Suffix (GV2P) Units 0 06 07 08 0 4 6 20 2 & 22 32 A 0..6 2.5 4 6.3 0 4 8 23 & 25 32 % 50 50 50 % 50 50 50 Ics 50 20 20 20 % 75 75 75 75 50 0 0 0 % 00 75 75 75 75 8 8 6 6 6 4 4 4 % 00 00 00 00 00 00 00 00 am gl am 00 00 00 gl 25 25 25 am 50 63 80 80 A gl 63 80 00 00 am 50 50 50 50 50 gl 63 63 63 63 63 am 20 25 40 40 50 50 50 50 gl 25 32 50 50 63 63 63 63 9

Table 9: GV2P Breaking Capacity for European Applications When Used with Current Limiter GVL3 Type Units Catalog Number Suffix (GV2P ) 0 06 07 08 0 4 6 20 2 & 25 32 Rating [] A 0..6 2.5 4 6.3 0 4 8 2 & 23 32 Breaking capacity conforming to IEC 60947-2 230/240 V 400/45 V 440 V Ics % % 00 % 50 500 V 00 % 50 Ics = % of Icu. Table 20: GV2ME Breaking Capacity for European Applications When Used with Current Limiter GVL3 Type Units Catalog Number Suffix (GV2ME ) 0 to 06 07 08 0 4 6 20 2 22 Rating [] A 0..6 2.5 4 6.3 0 4 8 23 25 230/240 V % Breaking capacity conforming to IEC 60947-2 400/45 V 440 V Ics 00 00 00 00 % 50 50 40 40 50 20 20 20 % 75 75 75 75 500 V 50 0 0 0 % 00 00 75 75 75 Rating A 0..6 2.5 4 6.3 0 4 8 23 25 Ics = % of Icu. 20