DI-SP/TP. Operators Guide SUBMERSIBLE HYDRAULIC PUMPS HDI Inc. PO Box 1671 Gresham OR (FAX)

Similar documents
3 SUBMERSIBLE HYDRAPUMP INSTRUCTIONS

HYDRAULIC TRASH PUMP. User s Manual TP03 SERIOUS INJURY OR DEATH COULD RESULT FROM THE IMPROPER REPAIR OR SERVICE OF THIS TOOL.

PARTS AND INSTALLATION MANUAL

DUAL PURPOSE DIAGNOSTIC LEAK DETECTOR

GROUND ROD DRIVER 5/8 & 1 INSTRUCTIONS

Hydraulic PTO Flow Device

Mulcher Operators Manual

Short Rams. Operating Instructions & Parts Manual. Model Number B65141 B Capacity 2 Ton 10 Ton

Hydraulic Immediate Need Power Pack

CDS-JOHN BLUE COMPANY

HWP2/HWP3/HWP4 Hydraulic Submersible Pumps

MODEL 5120 Tire Repair Station

PPM EO-100 TM. Operation Manual

Troubleshooting WARNING

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Illumifalls Patio Pond

Operator s Manual. Nitro 1000 Nitro 1000X. Nitro 750 Nitro 750X. September REV0

MODEL 900 IMPELLER-TYPE FLOW METER

Rams. Operating Instructions & Parts Manual. Model Number B65142 B65150 B65442 B65444 B65452 B Capacity 4 Ton 4 Ton 10 Ton 10 Ton 10 Ton 25 Ton

Pressure Washer Hose Reel

2 Speed Hydraulic Hand Pump

CDS-JOHN BLUE COMPANY

Rams. Operating Instructions & Parts Manual. Model Number B65141 B65553 B65555 B65441 B65446 B65449 B65746

Heavy Duty Engine Cranes

Operator's Manual. VC-60 & VC-60 Plus Harper Industries, Inc. 7/03 Part No

Premium Supply. Direct Push. Models PCK-3530-DP PCK DP PCK-530-DP. Operator s Manual and Installation Instructions

Telescopic Transmission Jacks

Air Actuated Hydraulic Treadle Pump

INSTALLATION AND OPERATING MANUAL

OWNERS MANUAL INSTALLATION AND OPERATING INSTRUCTIONS REPAIR PARTS LIST. Centrifugal Pump Primer MODEL 6D, HAN-DEE PRIMER

StormPro BA Series Sump Pump

ESE Series Cast Iron Sewage Pumps

SHEYENNE TELE-BOOM OWNERS MANUAL OPERATOR INSTRUCTIONS PARTS BOOK

Hydraulic Air Pump. Operating Instructions & Parts Manual. Capacity 10,000 PSI. Model Number Atd-5812

Operating Instructions & Parts Manual. Air/Manual Hydraulic Bottle Jacks

Model GP Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Operating Instructions & Parts Manual

SUBMERSIBLE DIRTY WATER PUMP

Models P420A-3100 & P420A-5100

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance Troubleshooting

AS-57FMH Flush Mount Kit AS-57EBDBP

Voltmaster Centrifugal Trash Pumps

: 1250 gpm in the deck mode : 800 gpm while operating in the ground base - Dual Inlet : 1000 gpm while operating in the ground base - Single Inlet

OWNER S MANUAL SELF-PRIMING PORTABLE UTILITY PUMP

INSTALLATION AND OPERATING MANUAL

MODELS 94100, 94300, and BARE REEL SERIES A OWNER/OPERATOR MANUAL

INSTALLATION AND OPERATING

MetroPrime 22MPC Self-Priming Centrifugal Pump

OPERATION & MAINTENANCE INSTRUCTIONS

Air Actuated Hydraulic Bottle Jacks

PARTS AND INSTALLATION MANUAL

Hydraulic Transmission Jack, Telescopic

Model. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual SP100W/SP351W

J. & M. Mfg. Co., Inc. 284 Railroad Street - P.O. Box 547 Fort Recovery, OH Ph: (419) Fax: (419)

Heavy Duty Jack Stands

OWNER/OPERATOR MANUAL. Airmotor effective dia. in. 2.5

Single Acting Aluminum Cylinders Instruction Manual

GARDEN HOSE UTILITY PUMP

FPC815 Pneumatic Rivet Tool

LUBRICATOR GUN INSTRUCTIONS-PARTS LIST. 10,000 psi (700 bar) Maximum Delivery Pressure. Detachable-type

Maximum Operating Pressure 10,000 PSI

Hydraulic Long Jacks

High Tonnage Single Acting Cylinders Instruction Manual

11202 INSTALLATION INSTRUCTIONS

OPERATING INSTRUCTIONS AND PARTS MANUAL

Extreme Duty Grapple (Rock, Skeleton, Scrap & Tine) Operation and Maintenance Manual

Operating Instructions & Parts Manual

SUNC3000 / Item #40885

Telescoping Pressure Washer Wand 18'

MODEL 660 AUTOMATIC FASTENING CENTER OPERATOR S MANUAL

MODEL BARE REEL SERIES E

MODEL 200 MULTI-JET FLOW METER

Sawhorse with Chainsaw Holder

The following is intended to provide the basic instructions for installation, operating and maintenance of the Severe Duty Monitor.

IMPORTANT OPERATING CONDITIONS. Failure to comply with any of these conditions invalidates the warranty. STANDARD CONFIGURATIONS

Heavy Duty Engine Cranes

StormPro BCV400 Sewage Ejector Pump

MODEL EGA200 OWNERS MANUAL

Model CP420/CP425. Triplex Ceramic Plunger Pump Operating Instructions/ Repair and Service Manual

SUNC1200 / ITEM #40882 SUBMERSIBLE UTILITY PUMP OPERATIONS MANUAL

MODEL G300 BRAKE BLEEDER

Operating Manual. FloorMaster FS Flooring Stapler A18201 READ ALL SAFETY INSTRUCTIONS

Heavy-Duty Welding Fabrication Table

Gauge Adapter Instruction Manual

Model BP6150. Triplex Ceramic Plunger Pump Operating Instructions/ Manual

Pressure Roller with 24-inch Fixed Extension - For application of architectural paints and coatings -

Pro Shot Grease Dispense Valve

INSTRUCTION MANUAL IM245. RGS2012E1 S or E Retrofit Kit SUBMERSIBLE GRINDER PUMP INSTALLATION, OPERATION AND TROUBLESHOOTING MANUAL

Submersible Pond Pump with UV 800 Gallons Per Hour

Getz Equipment Innovators 450 lb Portable / Wheeled Unit Dry Chemical Fill System Part No: 3G0061/3G0063

SPECIFICATIONS CONTENTS: Specifications Warning Information. Operating Instructions Preventative Maintenance and Troubleshooting

Model: PFUPPP M10. 1/4 HP 3450 RPM 60 Hz Submersible Utility Pump OWNER S MANUAL. Power-Flo Pumps & Systems PUMPS

G8 Portable Fuel Transfer Pump Owner s Manual

Model F822 thru F834 Mulsifyre Directional Spray Nozzles, Open, High Velocity General Description

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

Hydraulic Truck Jack

Low Pressure Fluid Filters

AEROMOTIVE Part # Street Rod Fuel Pump System INSTALLATION INSTRUCTIONS

110 Volt/12 Volt Portable Inflator

Adjustable Steel Welding Table

Transcription:

DI-SP/TP SUBMERSIBLE HYDRAULIC PUMPS Operators Guide 2013 HDI Inc. PO Box 1671 Gresham OR 7030 206 274 4855 (FAX)

SAFETY PRECAUTIONS INTRODUCTION Our hydraulically powered submersible dewatering and trash pumps have been engineered to provide long lasting pumping performance with economic advantages that no other pump can match. Yet, even a well-designed and well-built pump can malfunction or become hazardous in the hands of an experienced or untrained user. Anyone that operates or comes in contact with these products must thoroughly read and understand this manual and related equipment manuals prior to handling, operating or servicing these pumps. SAFETY RULES 1. Only use the pump in accordance with the manufacturer s specifications and limitations. 2. Only trained personnel shall operate the pump, conduct maintenance or repairs. A trained person has read and thoroughly understands this instruction manual and related equipment manuals and, through training and experience, has shown knowledge regarding safe operational procedures. 3. Always use appropriate personal protection equipment (PPE) including, but not limited to: eye and ear protection, safety shoes, hard hat and work gloves. 4. Safety goggles must be worn at all times by the operator and any persons or bystanders within 0 feet of the pump or its discharge point. 5. Never lift or lower the pump by its hydraulic hoses; use a cable and a lifting eye where applicable. 6. Do not use any hose showing signs of damage or wear, including both hydraulic and discharge hoses. 7. Secure the discharge hose before operating. 8. Do not allow the discharge hose to be kinked while in operation. If pumping in a shallow basin use a 0 degree elbow on the pump to prevent kinking.. Keep all body parts clear from discharge hose and pump inlet. Keep all body parts away from pressurized hydraulic hoses.. Always stop hydraulic power source and depressurize the hydraulic system before connecting or disconnecting hydraulic hoses. 11. Never try to adjust or service the pump while connected to a hydraulic power source. 12. Hydraulic hoses must be rated for 2500 PSI working pressure and hydraulic power source must not provide more than 2250 PSI at any time. 1

OPERATION AND MAINTENANCE BEFORE OPERATION 1. Anyone that operates or comes in contact with these products must thoroughly read and understand this manual and related equipment manuals prior to handling, operating or servicing these pumps. 2. Check hydraulic flow and relief pressure at the power source. Never exceed the pumps maximum flow rate or pressure. The power source must be open center, single directional and have an unrestricted flow from the pump back to the reservoir. 3. Inspect all hoses for breaks, cracks, abrasions, kinks, bulges or erosion from chemical exposure before use. Replace damaged hoses before use. Inspect pump for damage and insure all decals and warning labels are intact and legible. SET UP AND WORK AREA 1. Do not allow the discharge hose to be kinked while in operation. If pumping in a shallow basin use a 0 degree elbow on the pump to prevent kinking. 2. Keep all body parts clear from discharge hose and pump inlet. Keep all body parts away from pressurized hydraulic hoses. 3. Ensure all coworkers and bystanders are kept at a safe distance from all mechanical equipment including the pump and its discharge point. 4. To start the pump, turn on the hydraulic flow making sure not to exceed the rated flows and pressures. 5. If the pump fails to perform, properly check the troubleshooting chart in the back of this manual for possible causes. Never attempt to service the pump while connected to a hydraulic power source. DAILY MAINTENANCE 1. Inspect hoses for breaks, cracks or abrasions. Never attempt to repair a hose; replace damaged hoses immediately. 2. Disconnect and clean hydraulic hoses and couplers after each use to prevent the introduction of foreign material into the hydraulic system. 3. Ensure all fasteners are tight. 4. Replace all parts that are broken or worn before each use. 5. Clean pump thoroughly before storage to prevent excessive build-up that could cause damage or restrict performance. 2

SP20 2 DISCHARGE SUBMERSIBLE WATER PUMP 150 PERFORMANCE 125 Head (Feet) 0 75 50 25 0 8 GPM 5 GPM 50 0 150 200 250 Testing was done in a controlled environment with a fixed discharge assembly using regulated pressures and flows. Results could vary in field conditions. Water Volume (GPM) SP20 2.0 SUBMERSIBLE WATER PUMP SPECIFICATIONS PUMPING CAPACITY 250 gpm (46 lpm) PUMP TYPE Water CONSTRUCTION Aluminum Body/Stainless Impeller DISCHARGE 2 Cam Loc - 2 NPT Female WEIGHT 12 lbs. (5.5 kg) LENGTH.5 inches (241 mm) WIDTH 8 inches (203 mm) HEIGHT inches (22 mm) HYDRAULIC FLOW RANGE 4- gpm (15-34 lpm) MAXIMUM PRESSURE 2000 psi (138 bar) MAXIMUM BACK PRESSURE 250 psi (17 bar) WARRANTY - Submersible Pumps and their associated parts are warranted against defects in material and workmanship for a period of twelve months from the date of purchase. Repair or replacement of defective parts will be approved by manufacturer. This warranty becomes void if maximum pressures or flows are exceeded. Backpressure should be measured at the tool before being used. Excessive backpressure will damage shaft seal. 3

13 16 15 6 11 12 3 4 14 SP20 PARTS LIST 1 EP251 Volute 2-1/2 Inch 1 2 EP202 Impeller 1 3 EP203 Motor Assembly 1 4 EP204 Motor Mount 1 5 EP205 Motor Mount Bolts 3 6 EP206 Motor Mount Washers 3 7 EP207 Impeller Bolt 1 8 EP208 Impeller Lock Washer 1 EP20 Impeller Washer 1 EP215 Cam Loc 2-1/2 1 11 EP211 Impeller Shim.0 1 12 EP212 Impeller Shim.020 1 13 EP308 FF Coupler Set 1 14 EP316 Motor Shaft Key 1 15 EP208 Flange Lock Washer 2 16 EP213 Flange Bolt 2 EP214 Seal Kit 1 EP216 Decal Kit 1 5 2 8 7 1 4

SP25 2.5 DISCHARGE SUBMERSIBLE WATER PUMP 150 PERFORMANCE 125 Head (Feet) 0 75 50 25 0 8 GPM 5 GPM 50 0 150 200 250 Testing was done in a controlled environment with a fixed discharge assembly using regulated pressures and flows. Results could vary in field conditions. Water Volume (GPM) SP25 2.5 SUBMERSIBLE WATER PUMP SPECIFICATIONS PUMPING CAPACITY 275 gpm (40 lpm) PUMP TYPE Water CONSTRUCTION Aluminum Body/Stainless Impeller DISCHARGE 2-1/2 Cam Loc - 2-1/2 NPT Male WEIGHT 12 lbs. (5.5 kg) LENGTH.5 inches (241 mm) WIDTH 8 inches (203 mm) HEIGHT inches (22 mm) HYDRAULIC FLOW RANGE 4-8 gpm (15-30 lpm) MAXIMUM PRESSURE 2000 psi (138 bar) MAXIMUM BACK PRESSURE 250 psi (17 bar) WARRANTY - Submersible Pumps and their associated parts are warranted against defects in material and workmanship for a period of twelve months from the date of purchase. Repair or replacement of defective parts will be approved by manufacturer. This warranty becomes void if maximum pressures or flows are exceeded. Backpressure should be measured at the tool before being used. Excessive backpressure will damage shaft seal. 5

13 16 15 6 11 12 3 4 14 SP25 PARTS LIST 1 EP251 Volute 2-1/2 Inch 1 2 EP202 Impeller 1 3 EP203 Motor Assembly 1 4 EP204 Motor Mount 1 5 EP205 Motor Mount Bolts 3 6 EP206 Motor Mount Washers 3 7 EP207 Impeller Bolt 1 8 EP208 Impeller Lock Washer 1 EP20 Impeller Washer 1 EP215 Cam Loc 2-1/2 1 11 EP211 Impeller Shim.0 1 12 EP212 Impeller Shim.020 1 13 EP308 FF Coupler Set 1 14 EP316 Motor Shaft Key 1 15 EP208 Flange Lock Washer 2 16 EP213 Flange Bolt 2 EP214 Seal Kit 1 EP216 Decal Kit 1 5 2 8 7 1 6

SP30 3 DISCHARGE SUBMERSIBLE WATER PUMP 120 PERFORMANCE 0 GPM Head (Feet) 80 60 40 20 0 GPM 8 GPM 7 GPM 6 GPM 200 300 400 500 600 Testing was done in a controlled environment with a fixed discharge assembly using regulated pressures and flows. Results could vary in field conditions. Water Volume (GPM) SP30 3 SUBMERSIBLE WATER PUMP SPECIFICATIONS PUMPING CAPACITY 500 gpm (183 lpm) PUMP TYPE Water CONSTRUCTION Aluminum Body/Stainless Impeller DISCHARGE 3 Cam Loc - 3 NPT Female WEIGHT 21 lbs. (.5 kg) LENGTH 12 inches (305 mm) WIDTH inches (254 mm) HEIGHT 12 inches (305 mm) HYDRAULIC FLOW RANGE 7-11 gpm (26-42 lpm) MAXIMUM PRESSURE 2000 psi (138 bar) MAXIMUM BACK PRESSURE 250 psi (17 bar) WARRANTY - Submersible Pumps and their associated parts are warranted against defects in material and workmanship for a period of twelve months from the date of purchase. Repair or replacement of defective parts will be approved by manufacturer. This warranty becomes void if maximum pressures or flows are exceeded. Backpressure should be measured at the tool before being used. Excessive backpressure will damage shaft seal. 7

4 3 12 13 14 2 11 5 SP30 PARTS LIST P/N DESCRIPTION REQ 1 EP351 Volute 3 1 2 EP352 Impeller 1 3 EP353 Motor Assembly 1 4 EP354 Motor Mount Bolts 2 5 EP355 Motor Mount Washers 2 6 EP356 Lock Washers 2 7 EP207 Impeller Bolt 1 8 EP208 Impeller Lock Washer 1 EP20 Impeller Washer 1 EP211 Impeller Shim.0 1 11 EP212 Impeller Shim.020 1 12 EP360 Cam Loc 3 1 13 EP308 FF Coupler Set 1 14 EP316 Motor Shaft Key 1 EP364 Seal Kit 1 EP365 Decal Kit 1 6 7 8 1 8

TP30 3 DISCHARGE SUBMERSIBLE TRASH PUMP PERFORMANCE 0 GPM 80 Head (Feet) 60 40 20 0 8 GPM 5 GPM 0 200 300 400 500 Testing was done in a controlled environment with a fixed discharge assembly using regulated pressures and flows. Results could vary in field conditions. Water Volume (GPM) TP30 3 SUBMERSIBLE TRASH PUMP SPECIFICATIONS PUMPING CAPACITY 475 gpm (1800 lpm) PUMP TYPE Trash-Sludge-Slurry-Water CONSTRUCTION Urethane Volute and Impeller DISCHARGE 3 Cam Loc - 3 NPT Female WEIGHT 30 lbs. (13.6 kg) LENGTH 14 inches (355 mm) WIDTH 12 inches (305 mm) HEIGHT 13 inches (330 mm) HYDRAULIC FLOW RANGE 7-11 gpm (26-42 lpm) MAXIMUM PRESSURE 2000 psi (138 bar) MAXIMUM BACK PRESSURE 250 psi (17 bar) WARRANTY - Submersible Pumps and their associated parts are warranted against defects in material and workmanship for a period of twelve months from the date of purchase. Repair or replacement of defective parts will be approved by manufacturer. This warranty becomes void if maximum pressures or flows are exceeded. Backpressure should be measured at the tool before being used. Excessive backpressure will damage shaft seal.

6 7 8 11 8 12 13 5 4 TP30 PARTS LIST P/N DESCRIPTION REQ 1 EP301 Wingnut 6 2 EP302 Stud 6 3 EP303 Lifting Eye 1 14 15 16 3 4 EP304 Motor 1 5 EP305 Urethane Volute 1 6 EP306 Urethane Impeller 1 7 EP307 Base 1 8 EP308 FF Coupler Set 1 EP30 Impeller Bolt 1 EP3 Impeller Lock Washer 1 11 EP311 Impeller Washer 1 12 EP312 Base Mounting Nuts 3 13 EP313 Base Mounting Bolt 3 14 EP314 Motor Mount Bolts 2 15 EP315 Motor Mount Nuts 2 17 18 1 16 EP316 Motor Shaft Key 1 17 EP317 Motor Mount Plate 1 18 EP318 Cam Loc 3 Male 1 1 EP31 Carry handles 2 20 EP322 Base Mounting Washer 3 2 21 EP321 Gasket 1 EP364 Seal Kit EP365 Decal Kit 1

TP40 4 DISCHARGE SUBMERSIBLE TRASH PUMP PERFORMANCE 40 11 GPM Head (Feet) 30 20 0 GPM 7 GPM 250 375 500 635 750 875 00 Testing was done in a controlled environment with a fixed discharge assembly using regulated pressures and flows. Results could vary in field conditions. Water Volume (GPM) TP40 4 SUBMERSIBLE TRASH PUMP SPECIFICATIONS PUMPING CAPACITY 875 gpm (3312 lpm) PUMP TYPE Trash-Sludge-Slurry-Water CONSTRUCTION Steel Fabrication/Iron Impeller DISCHARGE 4 Cam Loc - 3 NPT Male WEIGHT 5 lbs. (26.8 kg) LENGTH 1 inches (482 mm) WIDTH 15 inches (381 mm) HEIGHT 1 inches (482 mm) HYDRAULIC FLOW RANGE 7- gpm (26-34 lpm) MAXIMUM PRESSURE 2000 psi (138 bar) MAXIMUM BACK PRESSURE 250 psi (17 bar) WARRANTY - Submersible Pumps and their associated parts are warranted against defects in material and workmanship for a period of twelve months from the date of purchase. Repair or replacement of defective parts will be approved by manufacturer. This warranty becomes void if maximum pressures or flows are exceeded. Backpressure should be measured at the tool before being used. Excessive backpressure will damage shaft seal. 11

24 21 25 3 23 17 8 4 8 7 20 1 18 2 12 22 TP40 PARTS LIST P/N DESCRIPTION REQ 16 11 5 6 1 EP401 Volute 1 2 EP402 Impeller 1 3 EP403 Motor Assembly 1 4 EP404 Woorruff Key 1 5 EP405 Washer 1 6 EP406 Impeller Nut 1 7 EP407 Motor Plate 1 8 EP408 Plate Bolt 6 EP40 Plate/Shoe washer 14 EP4 Plate/Shoe Lock Washer 14 11 EP411 UHMW Wear Plate 1 12 EP412 Wear Plate Screws 6 13 EP413 Wear Plate Nuts 6 14 EP414 Shoe 1 1 15 EP415 Shoe Bolts 8 16 EP417 4 Cam Loc 1 13 17 EP418 Carry Handle 1 18 EP420 Shim.020 1 1 EP421 Shim.040 1 20 EP422 Shim.080 1 14 21 EP308 FF Coupler Set 1 22 EP314 Motor Mount Bolts 2 23 EP315 Motor Mount Nuts 2 24 EP423 In Adaptor 1 25 EP424 Out adaptor 1 EP41 Seal Kit 15 EP425 Decal Kit 12

WARRANTY LIMITED PRODUCT WARRANTY Manufacturer warrants to the original purchaser that all products shall be free of defects in material and workmanship for a period of one year from the original date of sale. In no event shall the manufacturer be liable to the buyer or any other person or interest for any indirect, incidental or consequential damage or losses connected with the use or transportation of this product. Warranty is strictly limited to replacement or repair of the product only and is always at the sole discretion of the manufacturer. MANUFACTURER S OBLIGATIONS The manufacturer s sale obligation under this limited warranty is to repair and or replace parts deemed to be defective by the manufacturer. Parts and equipment cannot be returned without a returned goods authorization from the manufacturer. Shipping costs are not part of the warranty policy as most all warranty issues can be settled via electronic communications not limited to but including detailed photos. PARTS MANUFACTURED BY OTHERS This warranty does not cover components manufactured by others. These parts are subject to the warranty of the specific manufacturer. WARRANTY EXCEPTIONS The limited warranty does not include the following: 1. Equipment which has been abused, damaged, or used beyond its rated capacity or previously repaired by persons other than authorized service personnel. 2. Lost time or any other costs related directly or indirectly to the pumps performance or failure. 3. Any failure or performance deficiency attributed to misuse. Misuse is defined as any use of the product outside of its designed intent. 4. Costs of repairing damage caused by poor or improper maintenance. 5. Warranty of product that has been modified. 6. Transportation costs. 7. Any costs that exceed the value of a complete tool replacement. 13

TROUBLESHOOTING TROUBLESHOOTING TIPS AND FIELD SOLUTIONS If a performance problems occurs, consult the chart below for diagnoses and possible solutions. Before consulting the chart, ensure the pump is receiving the proper pressure and flow. Excessive back pressure directly effects pumps performance will prematurely wear out and destroy the shaft seal causing the pump to leak hydraulic fluid. Measure back pressure in hydraulic return line at power source during maximum recommended flow. PROBLEM CAUSE SOLUTION Pump will not pump water No Hydraulic Flow or Pressure Defective couplers or couplers hooked up backwards Impeller jammed with debris Pump Cavitates Check hydraulic pressure supply with a flow and pressure meter Replace couplers or install in correct orientation Take off cover, remove debris Clean weep hole if applicable, remove restrictions obstructing inlet Poor pump performance Hydraulic Fluid in discharge Hydraulic flow reversed Inadequate hydraulic fluid flow Pump submerged in sediment Pump Inlet restricted Discharge hose kinked or restricted Excessive system back pressure Water lift too high Impeller worn or damaged Motor shaft seal failure Check and correct, these pumps can not work properly using as reversing valve Check hydraulic pressure supply with a flow and pressure meter Remove from sediment Inspect and clean Inspect and clean Inspect and reroute return line if necessary Reduce lift to recommended height Inspect adjust, shim or replace Reseal hydraulic motor 14

Assembled and Tested in USA using Global Materials HDI INC. PO Box 1671 Gresham OR 7030 pumps@hdi-inc.com 206 247 4855 (FAX) 2013 HDI Inc. All Rights Reserved.