SIRIUS Online UPS. data CeNTReS. TeleCoMMUNICATIoN devices. MedICAl devices. emergency devices. TRANSPoRTATIoN. Smart Energy Solutions

Similar documents
Sirius series. UPS kva single/single-phase and three/single-phase kva three/three-phase. online

SR series. on-line

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

TELECOM- MUNICATIONS DEVICES INDUSTRIAL EMERGENCY DEVICES. (Servers Farms, ISP/ASP/POP)

EMERGENCY ELECTRO- MEDICAL INDUSTRIAL PLCS DEVICES. (Lights/Alarms)

SUPREME kva three-phase/single-phase 10-80kVA three-phase/three-phase

tel: Enhanced Power Services Limited Industrial PLCs Electro Medical Devices

UPS Multi Sentry 10-20kVA

Multi DIALOG MDM/MDT. MDM 10-20kVA single/single-phase and three/single-phase MDT 10-80kVA three/three-phase NETWORK RANGE

Master Plus kva

INDUSTRIAL PROCESSES TELECOM- MUNICATIONS DEVICES EMERGENCY DEVICES INDUSTRIAL

Master MPS kva kva 3:1 3:3 VFI TYPE

UPS Sentry HPS. power supply sources - isolation transformers and generators over less sophisticated power systems.

Master DIALOG INDUSTRY RANGE

Master MPS kva kva 3:1 3:3 VFI TYPE

Master MPS. Highlights kva kva. Three-phase/Three-phase. Three-phase/Single-phase

Phase Modular Finally the benefits of Modular ups are for all

Master MPS kva kva 3:1 3:3 VFI TYPE

BMPM/ BMPT Series. 3: kva VFI TYPE. Efficiency Control System (ECS) Robust and reliable Galvanic isolation High overload capacity

Master Plus kva

set out in standard IEC EN ). Multi Sentry is designed and built using state-of-the-art technology and components.

Multi Sentry kva kva 3:3 VFI. Complete range kva Small footprint

DELPHYS GP. Green Power 2.0 range 160 to 1000 kva/kw

MKN-DSP SERIES - THREE PHASE

TECHNICAL DATA SHEET KVA UPS Systemss

EFFEKTA Power Supplies

PowerScale TECHNICAL SPECIFICATIONS

D Series: UPS UPTO - 300KVA - Three / Three Phase

Technical data sheet VH UL. Digital Energy Uninterruptible Power Supply. GE Digital Energy Power Quality

Industrial PFC UPS System

Technical Specifications. Sentinel PRO 700 VA up to 3000 VA 1000 VA ER-2200 VA ER-3300 VA ER

PowerScale kva Technical Specifications

gimagination at work Technical data sheet Uninterruptible Power Supply LP Series 6 & 10 kva GE Digital Energy

Technical Specification SENTINEL PRO

Technical data sheets

Series. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Rack Mount. Your Tailored Power Solutions Provider TM

SENTINEL VA

» Sophisticated» Reliable» Intelligent

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

PowerWave 33 Efficient power protection for today s IT and process-related work environments

POWER+ PREMIUM CBS. BS-EN Emergency electrical installations Electric power systems Emergency lighting Escape lighting

Series. Full Three Year Warranty. On-line, Single-phase Parallel Redundant UPS System. 6 and 10 kva Tower. Your Tailored Power Solutions Provider TM

KEOR HP. THREE-PHASE UPS from 100 to 800 kva GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

60 to 160 kva.

MASTERYS IP+ 10 to 80 kva

Green Power 2.0 MASTERYS GP

Liebert. FP 50Z kva

10 20KVA 3Ph/1Ph KVA 3Ph / 3Ph

MGE TM Galaxy TM 7000

HAIRF UPS. X5 Series KVA

PowerValue 11/31 T kva

Technical Data Sheets

YOUR POWER IN SAFE HANDS. E Series UPS

MGE TM Galaxy TM 7000 GFC

3ph UPS NS3000 series kVA

Technical Data Sheets

Technical Data Sheets

Eaton 93PS 8-40kW UPS Technical Specification Manufacturer s declaration in accordance with IEC

Liebert NXC. 10kVA - 60kVA. Compact, Efficient, and Reliable Power Solution

TECHNICAL DATA SHEET INFINITY kva 3Ph(in) 3Ph(out)

Est ComPower Mini UPS (3 Phase) CPX Mini 10 50kVA

kVA. Liebert NX. Enterprise-Scale UPS Protection For Medium And Large Data Centers

2033A Series. Where Reliability Breeds Confidence UNINTERRUPTIBLE POWER SUPPLY SYSTEMS ISO 9001 CERTIFIED

Technical Data Sheets

Onfiniti. 1 Phase UPS

Via Somalia, Cormano (MI) - ITALY Ph Fax:

POWERTRONIX QUASAR 5-40 KVA

Galaxy VM. From 160 kva to 1000 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity. schneider-electric.

Technical Data Sheets

ConceptpowerTM Modular kVA

On-line, Single Phase, Double Conversion UPS

Three Phase UPS Systems Range: 10 to 500kVA

Galaxy VM. From 160 kva to 1000 kva, 160 kva or 200 kva modular approach. Three-phase power protection

Technical Data Sheets

MODULAR THREE-PHASE AND SINGLE-PHASE UPS SYSTEM

SmartOnline S3MX Series 3-Phase 380/400/415V 60kVA 54kW On-Line Double-Conversion UPS

Technical Data Sheet. Uninterruptible Power Supply. Digital Energy. imagination at work

S2000 PRODUCT RANGE. Ultra compact

TECHNICAL DATA SHEET B8033FXS kva 3Ph(In) 3Ph(Out)

SmartOnline SVTX Series 3-Phase 380/400/415V 20kVA 18kW On-Line Double-Conversion UPS, Tower, Extended Run, SNMP Option

PowerWave 33 S kw Efficient and reliable power protection for IT equipment in small- and medium-sized organizations

SmartOnline SUT Series 3-Phase 208/120V 220/127V 30kVA 30kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

M4T, the latest generation of UPS by INFOSEC UPS SYSTEM. M4T 10 to 40 kva with built-in batteries.

UniStar III Series. Full Three Year Warranty. On-line, Single-phase UPS System. 1, 2, & 3kVA Tower Model

TECHNICAL DATA SHEET B8031 FXS kva 3Ph(In) 1Ph(Out)

MARUSON TECHNOLOGY. Uninterruptible Power Supply.

TLE Series UPS 400/500 kw With eboost Technology

SmartOnline SUT Series 3-Phase 208/120V 220/127V 20kVA 20kW On-Line Double- Conversion UPS, Tower, Extended Run, SNMP Option

Technical Data Sheets

Power Safety. Protect 8. Industrial UPS. Protect 8.31 Single Phase output 10 kva 120 kva. Protect 8.33 Three Phase output 10 kva 120 kva

Galaxy VM. From 160 kva to 1000 kva Three-phase power protection. apc.com/products

» Eco-Friendly. » Intelligent» Space Saving

MODULYS RM GP. Rack-mounted modular UPS system. Green Power 2.0 range up to 4 x 25 kw

MODULYS RM GP. Rack-mounted modular UPS system Green Power 2.0 range up to 4 x 25 kw

POWER kva Nominal output power (Cos φ0,8) kva Nominal output power (Cos φ1,0) kw >88 Efficiency (AC AC)

POWER kva

Three-phase UPS system DPA UPScale ST kw The modular UPS designed for lowand medium-power applications

TLE Series UPS 160/200/225/250 kw with eboost Technology

Technical data sheets

Transcription:

Online UPS 10 20 kva single/single-phase and three/single-phase 10 120 kva three/three-phase data CeNTReS TeleCoMMUNICATIoN devices MedICAl devices emergency devices TRANSPoRTATIoN Smart Energy Solutions

2 Product Overview MAIN CHARTeRISTICS: HIGH efficency MAXIMUM RelIABIlITY FleXIBIlITY ZeRo SoURCe IMPT SMART BATTeRY MANAGeMeNT THe SeRIeS IS IdeAl FoR PRoTeCTING INFoRMATIoN SYSTeMS, TeleCoMMUNICATIoNS, IT NeTWoRKS, ANd CRITICAl SYSTeMS IN GeNeRAl WHeRe THe RISKS ARISING FRoM A PooR-QUAlITY PoWeR SUPPlY MAY CoMPRoMISe THe CoNTINUITY of BUSINeSS ANd SeRVICeS ANd entail VeRY HIGH CoSTS. The Sirius Series is available in 10-20 kva three-phase or single-phase input and single-phase output models, and 10-120 kva three- phase input and output models, with double conversion on-line technology according to the VFI-SS-111 classification, as defined by the IEC EN 62040-3 standard. This UPS range has been designed and engineered with cutting-edge technologies and components. Controlled by digital signal processor (DSP), they guarantee maximum protection for the installations supplied, no impact on the power line and signifi cant energy savings. The high level of flexibility means that there is full compatibility both with three-phase power and with single-phase sources, thus eliminating any critical factors in the connection between UPS and system. MAXIMUM RelIABIlITY Transformerless, fully digital control with microprocessor, no break in static and manual transferring. The high frequency PWM (Pulse with modulation) for rectifier and inverter minimizes noise levels. The technology and the choice of highest specification components, allows exceptional performance in an extremely compact solution. The input PFC (Power Factor Correction) stage assures a power factor close to 1 and current distortion below 3%, without additional filters. Great availability: the 0.9 output power factor means up to 15% more active power available, guaranteeing a greater margin in UPS sizing for potential load increases. SMART BATTeRY MANAGeMeNT The wide input voltage range and the variations in frequency tolerance enable transfers to battery to be minimised and reduce battery charging and running-down cycles. True on-line double conversion technology protects the system against the full range of power irregularities, requiring fewer transfers to battery. In the parallel redundant configuration a battery string can be connected to have full battery capacity also in case of one UPS failure, without any additional accessory. The high frequency battery charger reduces ripple to negligible levels, prolonging battery life and maintaining high performance over a long period of time. Suitable for use with sealed VRLA, AGM, GEL lead or wet type Ni- Cd batteries. ZeRo SoURCe IMPT The superior technology of Sirius allows it be used where the site mains power supply is limited in capacity or power, is also supplied by an on-site generator and/or loads that generate problems with current harmonics. Sirius is designed to have a zero-impact on its upstream power supply (mains or generator). FleXIBIlITY Sirius can be used in the following different modes: Normal mode or online: Eco mode with 99% effi ciency Smart active to adapt operation to the quality of the mains supply; Stand-by off to lengthen component life; Frequency converter. Configurable Power Share sockets to ensure backup for the most critical loads or those programmed to operate only when mains power fails; Cold Start to switch on the UPS even when there is no mains power. Additional battery chargers to optimise charge time. Provide added backup capacity for extended runtimes; optional dual inputs up to 80kVA, and standard for sizes above; isolation transformers to vary neutral connectivity in the event of separate power sources or for galvanic isolation between input and output.

Communications 3 operating SYSTeMS SUPPoRTed Windows 95-OSR2, 98, Me, NT 4.0, 2000, XP, 2003 and latest versions; Linux; Novell Netware 3.x, 4.x, 5.x, 6; Mac OS X, 9.x; IBM OS/2 Warp and Server; HP OPEN VMS; The most widely used UNIX operating systems such as: IBM AIX, HP UNIX, SUN Solaris INTEL and SPARC, SCO Unix and UnixWare, Silicon Graphic IRIX, Compaq Tru64 UNIX and DEC UNIX, BSD UNIX and FreeBSD UNIX, NCR UNIX. UPSmod 5 provides user-friendly UPS management. The software displays real time information in the form of bar charts and values for critical data such as mains voltage, UPS load and battery charge. It allows remote interrogation of UPS logs and operating parameters to help diagnose alarms and potential fault conditions. When instructed, the software performs an automated safe power down of the protected PCs and file server. Advanced Communication Direct Connection with Ethernet Network POWER SUPPLY Sirius is equipped with a graphic display that provides information, measures, states and alarms regarding the UPS in 5 different languages RS232 or USB serial port 3 slots for the installation of optional communication accessories such as network adapters and volt-free contacts REPO (Remote Emergency Power Off) with which to power down the UPS through a remote emergency pushbutton for connection of the auxiliary contact of an external manual bypass for synchronization from an external source Graphic mimic panel display for remote connection The SNMP agent allows UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface via SNMP LINK RS232 RS232 Terminals Administrating Workstation Windows Workstation SNMP TRAP WEB PAGE SNMP ETHERNET NETWORK SHUTDOWN SHUTDOWN Server 1 Server 2

4 UPS - configuration SWMB Maintenance by-pass switch Line In PFC CONVERTER INVERTER Automatic static by-pass Line Out SWIN breaker Relay Battery charger Stand-by switch SWOUT Output breaker SWBATT Battery MENU: 1. SYSTEM ON 2. SYSTEM STAND-BY 3. TEMPERATURE 4. COMMAND 5. HISTORY 6. WAVEFORM 7. DIAGNOSTICS 8. CONFIGURATION Parallel Configuration BYPASS LINE Parallel redundant configurations allow for the failure of a single UPS module without requiring that the critical load is transferred to the utility source. A parallel redundant configuration consists of paralleling multiple, same size UPS modules into a common output bus. Sirius can work in parallel up to 4 units in threephase/singlephase and up to 6 units in threephase/threephase. The UPS continues to operate in parallel if one of the communication cables is disconnected. LOAD

High Efficiency 5 PoWeR loss 8400 KWH 33,5% difference PoWeR loss 12600 KWH energy SAVed 4200 KWH* 40 kva Effi ciency 96% at 75% rated load STANdARd UPS 40 kva Effi ciency 88% at 75% rated load * for standard utility contract at 0,15 /kwh that means 630 saved per year. Green Technology Sirius is 96% efficient whereas other UPS products on the market achieve only 92% efficiency. If Sirius is used with Ecomode 99% efficiency can be achieved. This means a power saving of over 50%. The investment is paid back over the working of the UPS. % Effi ciency 40 kva traditional UPS 40 kva 100 98 96 94 92 90 88 86 84 82 80 78 76 0 20 30 40 60 80 100 120 % load

6 Technical Specifications Model SR010M SR012M SR015M SR020M Rated voltage Voltage range Rated frequency Frequency range INPUT 380-400-415 Vac three-phase with Neutral / 220-230-240 single-phase 320-480V @ 100% load; 240-480V @ 50% load (3ph) 184-276V @ 100% load; 140-276V @ 50% load (1ph) 50/60 Hz 40 72 Hz Power factor at full load 0.99 Current distorsion THDI 3% Rated Voltage Voltage tolerance Rated frequency Frequency tolerance By Pass 220-230-240 Vac single phase with neutral 180 264 V (selectable) 50/60 Hz (selectable) ±5 (selectable) OUTPUT Rated power (kva) 10 12 15 20 Active power (kw) 9 10.8 13.5 18 Output power factor 0.9 Rated voltage (V) 220-230-240 Vac (selectable) single phase with neutral Static variation ± 1% Dynamic variation ± 3% Crest factor (Ipeak/Irms) 3: 1 Voltage distortion Frequency 1% with linear load / 3% with non-linear load 50/60 Hz Frequency stability on battery mode 0.01% Overload at pf 0.8 Number of VRLA batteries Type Recharge time 110% for 10 minutes, 133% for 1 minute, 150% for 5 seconds BATTERIES 40 batt. 12V (internal up to 2 strings 9 Ah) VRLA AGM/GEL; Ni-Cd; WET TYPE 6 h ENVIRONMENTAL Weight with internal batteries (Kg) 315 320 325 330 Dimensions (HxWxD) (mm) Communication Operating temperature Relative humidity 1320x440x850 DOUBLE RS232/C - SNMP Agent - MODBUS - PROFIBUS 0 C / +40 C 90% non condensing Colour Dark Grey RAL 7016 Noise At 1m < 48 dba < 52 dba Protection rating Efficiency Normal Mode 93,3% 93,5% 93,8% 94% European Directives: L V 2006/95/CE Low voltage directive; EMC 2004/108/EC Electromagnetic compatibility directive Compliance Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111 IP20 Note: product specifications are subject to change without further notice

Technical Specifications 7 Model SR010T SR012T SR015T SR020T SR030T SR040T SR060T SR080T SR100T SR120T INPUT Rated voltage Voltage range Rated Frequency Frequency range 380-400-415 Vac, three-phase with Neutral 320-480V@100% of the load 240-480 V@50% of the load 50/60 Hz 40 72 Hz Power factor at full load 0.99 Current distortion THDI 3% BY PASS Rated voltage Voltage tolerance Rated frequency Frequency tolerance 380-400-415 Vac, three-phase with Neutral 180 264 V (selectable) 50/60 Hz (selectable) ±5 (selectable) OUTPUT Rated power (kva) 10 12 15 20 30 40 60 80 100 120 Active power (kw) 9 10.8 13.5 18 27 36 54 72 90 108 Output power factor 0.9 Rated voltage (V) 380-400-415 Vac (selectable), three phase with neutral Static variation ± 1% Dynamic variation ± 3% Crest factor (Ipeak/Irms) 3: 1 Voltage distortion Frequency 1% with linear load / 3% with non-linear load 50/60 Hz Frequency stability on battery mode 0.01% Overload at pf 0.8 115% unlimited, 125% for 10 minutes, 150% for 1 minute, 168% for 5 seconds BATTERIES Number of VRLA batteries 40 batt. 12V (internal up to 2 strings 9 Ah) 40 batt. 12V (external) Type Recharge time VRLA AGM/GEL; Ni-Cd; WET TYPE 6 h ENVIRONMENTAL Weight* (Kg) 315 320 325 330 345 355 190 200 220 380 Dimensions (HxWxD) (mm) 1320x440x850 1600x500x850 Communication DOUBLE RS232/C - SNMP Agent - MODBUS - PROFIBUS 1900x 750x 855 Operating temperature Relative humidity 0 C / +40 C 90% non condensing Colour Dark Grey RAL 7016 Noise at 1 mt < 48 dba < 52 dba < 48 dba < 56 dba <58 dba < 70 dba Protection rating IP20 Efficiency Normal Mode 93,5% up to 94% up to 96% up to 95% 93% Compliance European Directives: L V 2006/95/CE Low voltage directive; EMC 2004/108/EC Electromagnetic compatibility directive Standards: Safety IEC EN 62040-1; EMC IEC EN 62040-2 C2 Classification according to IEC 62040-3 (Voltage Frequency Independent) VFI - SS - 111 * with internal batteries where applicable Note: product specifications are subject to change without further notice

G-Tec Service G-TeC Service, our technical assistance facility, employs highly trained engineers able to provide a reliable sales assistance service. A dedicated CAll CeNTRe for connection repairs. Contracts range from periodic in- to the G-TEC Service organisation. G-TEC spections to comprehensive cover including Service personnel are always on hand and labour and materials. happy to provide advice and assistance regarding the installation, maintenance, fault FAST & ReAdY: fast repair on site is gua- fi nding and repair of UPS equipment. ranteed thanks to the use of state-of-the- G-TEC Service can provide assistance art UPS technology and the professiona- during commissioning and start-up of the lism of the G-TEC Service personnel and UPS equipment on-site with additional Authorised Assistance Centres. training of site personnel during handover. G-TEC Service guarantees that failed parts are replaced with original ones and are te- MAINTeNANCe CoNTRTS can be prosted and updated in order to maintain the vided by G-TEC Service Partners to minimi- safety, reliability and operating characterise response times and reduce the cost of stics of the UPS system. www.gtec-power.eu www.gtec-power.eu G-Tec Europe srl Strada Marosticana, 81/13 36031 Povolaro (VI), Italia Tel. +39 0444.361321 - Fax +39 0444.365191 info@gtec-power.eu Rev. 07/08/2014