Application Note Three Phase String Inverters NEC 2014 Compliance

Similar documents
CPS 3Phs String Inverters NEC 2014 Compliance

SUPPLEMENTAL CORRECTION SHEET FOR SOLAR PHOTOVOLTAIC SYSTEMS - ELECTRICAL

2016 Photovoltaic Solar System Plan Review List

This is intended to provide uniform application of the codes by the plan check staff and to help the public apply the codes correctly.

Residential microinverter system

SunLink PV System Disconnect with Arc Fault Detection Installation and Operations Manual

Residential Photovoltaic (PV) Packet

Photovoltaic Solar Plan Review

CP-250E-60/72-208/240-MC4 Microinverter with Modular Trunk Cable

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

Solar PV Standard Plan Simplified Central/String Inverter Systems for One- and Two-Family Dwellings

PV Vault Yielding safety quickly

FRONIUS RAPID SHUTDOWN BOX MOUNTING OPTIONS For Rail and Rail-less systems on L-feet, stand-offs, and other attachment types

Solar Power Installation Application

SOLAR PV STANDARD PLAN - COMPREHENSIVE Central/String Inverter Systems for One and Two Family Dwellings

Photovoltaic Installations

Bulletin Wiring methods for solar photovoltaic systems Rules 2-034, , , , , Tables 11 and 19

Minnesota Dept. of Commerce, Division of Energy Resources. Distributed Generation Workshop Interconnection Standards

EXPANSION JOINT DETAILS DURA-BLOK CONDUIT SUPPORT CONDUIT ATTACHMENT DETAIL SCALE: NOT TO SCALE GROUNDING WIRE DETAIL SCALE: NOT TO SCALE

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

City of Manhattan Beach Community Development

Inspector Training Workshops Module One Photovoltaic Labeling based on 2008 NEC

SECTION 1: Field Inspection Guide for Rooftop Photovoltaic (PV) Systems

Bulletin Wiring methods for Solar Photovoltaic Systems Rules, 2-034, , and , Tables 11 and 19

Document Requirements for Engineering Review- PV Systems v1.1 12/6/2018

Pika Energy Island Made in America

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Update to the 2014 NEC Changes for PV

Solar PV Standard Electrical Plan

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

Technical Summary of Battery Energy Storage Systems

First Responder System Identification Quiz. Presented by the NY-SUN PV Trainers Network

CHAPTER 10 ELECTRICAL. Notes:

Optimizing Emergency Power Systems for Health Care Applications

Green Building Technology

NC PV DG Program SEPA Presentation. December 15, 2011

Solar Combiner Solutions

Non-Residential Solar Energy Photovoltaic (PV) Packet

Mike Holt s Illustrated Guide to SOLAR PV SYSTEMS

2011/2008/2005 NATIONAL ELECTRICAL CODE SOLAR PV CODE COMPLIANCE REFERENCE

Bussmann 10x38mm Photovoltaic fuses 1000Vdc, 1-30A

CHAPTER 10 ELECTRICAL

INSPECTION REQUIREMENTS: PHOTOVOLTAIC (PV) RESIDENTIAL

Arial Regular 25pt. Learn Solar Installation From the Pros!

STOREDGE TM. SolarEdge Single Phase StorEdge TM Solutions for North America SolarEdge StorEdge Solutions Benefits:

ENGINEERING SPECIFICATION

City of Manhattan Beach Community Development

Solar Combiner Solutions

Ginlong Solis US 4G PV Single-Phase String Inverters; 6 kw through 10 kw. Terence Parker Ginlong Technologies

Document Requirements for Engineering Review PV Systems v1.0 6/9/2017

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

Product manual Rapid Shutdown (RSD) system for residential and small commercial

Questions from the AHJ To Fuse or Not to Fuse?

CP /240-MC4 User Manual

Definitions. Scope. Customer Generation Interconnection Requirements

SOLAR PV INSTALLATIONS

Microinverters and AC PV modules are becoming. Microinverters and AC PV Modules. Different Beasts. Perspectives on PV.

ELECTRIC SERVICE RULES DISTRIBUTED GENERATION Issued Jan 2016

Shining a Light On Commercial Building Solar Ready Requirements

CPS Energy Balancer. Version: 1.0

RESIDENTIAL PHOTOVOLTAIC (PV) PACKET

Arc Fault Circuit Interrupter (AFCI) FACT SHEET

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

PHOTOVOLTAIC ELECTRICAL POWER SYSTEMS INSPECTOR/INSTALLER CHECKLIST

XL Style Photovoltaic Fuse Links for Solar Panel Applications 50 to 630A, 1000 & 1500Vdc PV Series

Enphase M215 PRODUCTIVE SIMPLE RELIABLE. Enphase Microinverters

9/7/2010. Objectives. Article 90. Introduction NEC Significant Changes. Review significant revisions in the 2011 NEC

CITY OF LANCASTER SPV TOOLKIT DOCUMENT #1

SBCB-6, SCCB-12, 28, 52 6 to 52 Circuit Combiner Boxes

Rated Current (Amps) Power Loss (Watts) 0.8 x I n 1 x I n PVM PVM PVM

Roof Top Solar Permit Document 1 Submittal Requirements Bulletin. Solar Photovoltaic Installations 10 kw or Less in One- and Two-Family Dwellings

40kW (and under) Solar/Inverter Installations Generation Interconnection Application to Minnesota Power

Georgia Tech Bunger Henry Solar Roof Array ENGINEERING PACKAGE

SIRCO PV UL98B Load break switches for photovoltaic applications from 100 to 2000 A - up to 1500 VDC

Quik-Spec Coordination Panelboard Specifications

RSDCOM. Installation and Operation Guide. Commercial Rapid Shutdown Combiner. DOCR Published March 2017 Revision C English

Productive. Reliable. Smart. Safe. Brandon J. Pierquet. The Impact of Microinverters in Photovoltaic Systems Enphase Energy

NEC REQUIREMENTS FOR GENERATORS

STREAMLINED SOLAR CHECKLIST Owner Name:

2. Fire Department Inspections are required and available by appointment on Tuesdays and Wednesdays. See item number four for fees.

Temporarily Approved Solar Photovoltaic System Electrical Schematics

Load Side PV Connections

3 Phase Power Systems - Designed for Canada

Health & Safety Issues Associated with Solar Photovoltaic (PV)

Energy & Cost Savings The Friends Meeting of Austin 3701 Martin Luther King Blvd. Austin, TX (46) Sharp 208 W Modules = 9.

Solar PV Standard Plan Simplified Microinverter and ACM Systems for One- and Two-Family Dwellings

Instruction of Solar Charge Controller. User s Manual

Solar Photovoltaic Power. Overarching Objectives. How many questions? 9/16/2012. From plan review to Final Inspection

PHOTOVOLTAIC SYSTEMS

Solar Standard Plan Simplified Systems for - and Two-Family Dwellings

PVGard 600 and 1000 Vdc solar photovoltaic circuit breakers

Continuing Education Course #206 Introduction to Designing Machine Control Systems Part 2

Combiner Manual #OMBINER #OMBINER < 2* )NSTALLATION 7(&+12/ i 62/$5

Micro3 Grid Tied Residential Package

HelioProtection HP10NH Photovoltaic fuse-links gpv 1000VDC

Solar PV Standard Plan Simplified Microinverter and ACM Systems for Oneand Two-Family Dwellings

Station Identification. Results. PV System Specifications. Energy Specifications. Solar Radiation (kwh/m 2 /day) Energy Value ($) AC Energy (kwh)

Model ESV Uninterruptible Power System 1.5 KVA/KW KVA/KW Single Phase

SOLAR PHOTOVOLTAIC SYSTEMS INSPECTOR CHECKLIST

Transcription:

Application Note Three Phase String Inverters NEC 2014 Compliance Version 2.0 July 07, 2014 The technical information and cross references of this document are subject to a continuous improvement and the right to change as may be technically or legally required is reserved. Code compliance for any PV System extends well beyond the specific design features of the inverter. This Application Guide is intended as a guide for our CPS customers, but is not a substitute for the comprehensive design and installation work required to comply with NEC 2014 code. For further questions: Chint Power Systems America Co. 700 International Parkway, Suite 102 Richardson, TX 75081 Tel: 855-584-7168 AmericaSales@chintpower.com 1

This application note describes the major changes in the National Electrical Code going from the 2011 to 2014 code cycle that effect photovoltaic installations and more specifically string inverters. NEC 2014 adoption varies state by state. Massachusetts, Nebraska, Washington, South Dakota, Minnesota, Maine, Kentucky, Idaho and Colorado have adopted 2014 code as of the release date of this Application Note. However, by the end of 2014, 18 more states plan to adopt NEC 2014. The NEC Adoption by state map is shown below as of June 30 th 2014. The major changes in NEC 2011 and 2014 that effect photovoltaic installations, and specifically are related to the application and use of inverters, are: 1. Section 690.5 - Ground Fault Protection 2. Section 690.11 - Arc-Fault Circuit Protection 3. Section 690.12 - Rapid Shutdown 4. Section 690.16 - Fuse Servicing The Application Note evaluates each of these sections with respect to the use of string inverter products, specifically CPS 23kW and CPS 28kW inverters. 2

1. Section 690.5 - Ground Fault Protection 690.5 Ground-Fault Protection. Grounded dc PV arrays shall be provided with dc ground-fault protection meeting the requirements of 690.5(A) through (C) to reduce fire hazards. Ungrounded dc PV arrays shall comply with 690.35. Exception: Ground-mounted or pole-mounted PV arrays The changes in this section effect the arrays and inverters in which at least one DC conductor is grounded. CPS three phase string inverters the arrays are floating (ungrounded) and are compliant with 690.35. Section 690.35 requires detection of ground faults via residual current monitoring and requires that the device providing ground fault protection (GFP) should be listed for that purpose. CPS inverters provide GFP and are listed for that function under UL 1741. 2. Section 690.11 - Arc-Fault 690.11 Arc-Fault Circuit Protection (Direct Current). Photovoltaic systems with dc source circuits, dc output circuits, or both, operating at a PV system maximum system voltage of 80 volts or greater, shall be protected by a listed (dc) arc-fault circuit interrupter, PV type, or other system components listed to provide equivalent protection. The PV arc-fault protection means shall comply with the following requirements: (1) The system shall detect and interrupt arcing faults resulting from a failure in the intended continuity of a conductor, connection, module, or other system component in the dc PV source and dc PV output circuits. (2) The system shall require that the disabled or disconnected equipment be manually restarted. (3) The system shall have an annunciator that provides a visual indication that the circuit interrupter has operated. This indication shall not reset automatically. CPS three phase string inverters come with an Arc-Fault Circuit Interrupter (AFCI) device as a standard feature set. This circuit board is located in the inverter wiring box. The AFCI device has been tested and listed to UL 1699B for the 23kW and 28kW inverters. In the event of an arc fault, the inverter will 3

detect and interrupt the ARC and disconnect from the grid. A visual indication through the error code on the LCD screen and the LED on the front panel is provided. The inverter will not restart until it is manually reset by engaging the inverter AC/DC disconnect switch off and then on again. After being turned on it will check to see if the error has been corrected before it starts exporting power. 3. Section 690.12 - Rapid Shutdown 690.12 Rapid Shutdown of PV Systems on Buildings. PV system circuits installed on or in buildings shall include a rapid shutdown function that controls specific conductors in accordance with 690.12(1) through (5) as follows. (1) Requirements for controlled conductors shall apply only to PV system conductors of more than 1.5 m (5 ft) in length inside a building, or more than 3 m (10 ft) from a PV array. (2) Controlled conductors shall be limited to not more than 30 volts and 240 volt-amperes within 10 seconds of rapid shutdown initiation. (3) Voltage and power shall be measured between any two conductors and between any conductor and ground. (4) The rapid shutdown initiation methods shall be labeled in accordance with 690.56(B). (5) Equipment that performs the rapid shutdown shall be listed and identified. The conditions outlined in this section can be met with string inverters. If the inverters are placed within 10ft of the perimeter of the array, they can support the requirement outlined in 690.12. The ac output conductors become the controlled conductors that are subject to the 690.12 requirements. The CPS 1000Vdc inverters (23kW and 28kW) have a unique ability to be 4

installed at a low tilt angle (15⁰) which improves the ability install these units near the array, particularly in a rooftop application. The inverters NEMA 4 rating supports this type of installation. Note, however, that the low tilt installation method is not necessary to comply with the code described above. The inverter can be installed on nearby parapet walls or by any other structural installation means. Low tilt install illustration Parapet wall installation example When there is a requirement for rapid shutdown the main AC disconnect for the system can be turned off. Doing so will cut off AC power to the inverter forcing it to shutdown in much less than 10 sec. Per the inverters UL1741 listing, the inverters are designed to turn off in 2 seconds if AC power is lost for any reason. Removing ac power will eliminate voltage and current on the controlled conductors, leaving only the conductors within the 10 foot array perimeter to remain energized. This feature, when combined with inverter location within 10ft of the perimeter of the array, enables the system to comply with 690.12.(2). To complete the compliance with this section, the installation will need to include labels per 690.56 identifying the rapid shutdown device for the PV system conductors. 5

4. Section 690.16 - Fuse Servicing Disconnects 690.16 Fuses. (A) Disconnecting Means. Disconnecting means shall be provided to disconnect a fuse from all sources of supply if the fuse is energized from both directions. Such a fuse in a PV source circuit shall be capable of being disconnected independently of fuses in other PV source circuits. (B) Fuse Servicing. Disconnecting means shall be installed on PV output circuits where over current devices (fuses) must be serviced that cannot be isolated from energized circuits. The disconnecting means shall be within sight of, and accessible to, the location of the fuse or 6

integral with fuse holder and shall comply with 690.17. Where the disconnecting means are located more than 1.8 m (6 ft) from the over current device, a directory showing the location of each disconnect shall be installed at the over current device location. Non-load-break-rated disconnecting means shall be marked Do not open under load. The wiring box for 23/28kW inverters are equipped with standard touch safe fuse holders (shipping beginning 10/1/2014, see Touch Safe Fuse Puller Retrofit Solution for product received before 10/1/2014) with pre-installed DC fuses and AC and DC disconnects to meet this requirement. The load break rated DC dis-connect opens the circuit on the output side of the fuse, between the fuse and the inverter to meet the requirements of 69016(A). Opening this switch stops all current from flowing from the array into the inverter and places the array into open circuit. There is still voltage present on the terminals but the conductors and fuses are no longer under load. The touch safe fuse holders can safely be used to independently remove the fuse, complying with 690.16(A) and (B). However, the touch safe fuse holders must not be opened under load. They are safely used only after the DC disconnect is turned to the OFF position. An alternate solution is provided by CPS for any customer seeking a touch safe fuse solution for an inverter received prior to October 1 st, 2014. The solution 7

includes a permanently attached fuse holder for each DC fuse in the wire-box (16 total), as shown below. This fuse holder solution can be provided at no charge upon customer request (contact your sales representative). *Touch Safe Fuse Puller Retrofit Solution Summary The CPS 23 and 28kW three phase string inverters comply with the NEC2014 code requirements outlined in Sections 690.5 (690.35), 690.11 and 690.16. The inverters include specific design features listed to meet these requirements. Section 690.12 (Rapid Shutdown) can be met with proper system design and installation techniques. The CPS 23 and 28kW, when placed within 10ft of the array perimeter, can support this requirement as the inverters will disconnect within 2 seconds of AC power loss. However, the system design and installation must follow all requirements of NEC code to support compliance and, as in all cases, should work with local AHJ s to ensure compliance. Please contact our Application Engineering staff if you have any questions or need assistance. 8