CHIP. Reverse Osmosis System Controller Documentation

Similar documents
ROC-2. icontrols. Reverse Osmosis System Controller Documentation

Duplex Booster System Instruction Manual

Thermaltake Warranty / Support Information

Generator Start Control Module

Generator Start Control Module

AC Irrigation and Propagation Controllers I Four Station, 5006-I and 5006-IP Six Station

WARNINGS, CAUTIONS AND NOTES

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

OPERATION MANUAL Variable Speed Pump Controller Dated: 06/04/2013 Pump Down Application. Document No.: LMSII_V100_OM Page 1 of 8 Model-V100 LMS II

i n s t r u c t i o n m a n u a l

Installation and Operation Guide

INSTRUCTION MANUAL INSTALLATION, OPERATION, AND MAINTENANCE ACTUATOR MANIFOLD

BRAVO Inverter/Battery Charger. Table of Contents

SUBMERSIBLE SUMP PUMPS

The function of this Dynamic Active Probe has divided into three preferences on the screen main Menus:

10 Year Limited Warranty

Owner s Guide ca4054 ca4554

PEDESTAL SUMP PUMP. MODEL # Español p. 11. Zoeller is a registered trademark of Zoeller Co. All Rights Reserved.

Two Channel Remote Shutdown Device

SUBMERSIBLE SUMP PUMPS

SOLAR DASH CHARGING SYSTEM USER GUIDE

SEWAGE PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 14

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Nature s Generator Power Panel

CA 5054 Owner s Guide

Generator Start Control Module

SPC-PANEL Simplex, Single Phase Pump Control Panel

TPAK Series COOLANT PUMP

INSTRUCTIONS FOR INSTALLING AND OPERATING THE UNIVERSAL AUTOSYNC MODEL ASPSS DUAL COMPRESSOR SEQUENCER CONSOLE S/N 1638 AND ABOVE

AUTOMATIC SUBMERSIBLE UTILITY PUMP

6. Electrical. 7. Settings. 8. Quick

Grundfos Variable Speed GRUNDFOS INSTRUCTIONS. Installation and Operation

Power Distribution System User s Manual. Model: PDS-100

NO SINGLE STAGE PROGRESSIVE, TPS, RPM WINDOW SWITCH

VP-4124/VP-4124-E 24/48 VOLT DC SWITCHING POWER SUPPLY

CAPACITOR ACTUATED PORTABLE STARTER CAPS USER GUIDE. INST048 Doc 3.01

Installation & Operation Manual. Electrak 10 Series / Electromechanical Linear Actuator

R & D SPECIALTIES ROTROL I USER'S MANUAL

Owner s Guide CA 4555

GARDEN HOSE UTILITY PUMP

PRE-PLUMBED SEWAGE SYSTEM

CBC-802 Plug-In Clutch/Brake Control with Solid State Switching

Digital echo-charge. Owner s Manual. Xantrex Digital echo-charge Battery Charger

Item no Smart AC 200 USB. User s Manual

Power. On Your Terms.

Owner s Guide CA 5055

GRINDER PUMP MODEL # Zoeller is a registered trademark of Zoeller Co. All Rights Reserved. Español p. 13

EZ SDI TM Booster Pump Assembly

Owner s Guide. ca5354

Model C230 Pump Controller

Owner s Guide. ca5154

SYSTEM MANUAL. Automated Motorized Hydraulic Traffic Controller. Revision CS72-HTC

Installation & Operation Manual. Electrak 100 Series / Electromechanical Linear Actuator

Model 809 Diaphragm Gauge Controller

TPHK Series Immersible Pump

DYNOTUNE 2 STAGE RPM WINDOW SWITCH WITH TPS INSTALLATION INSTRUCTIONS

Table of Contents. Page 2. midlandusa.com. Model PPG100

MAXIMIZER-II Progressive Nitrous Controller INSTALLATION AND USER MANUAL. MAXIMIZER-II rev A

10 Ch Peak & Hold Injector Driver PN

180w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-1800HC14

SELECT DIAGNOSTIC GUIDE. INST028 Doc 3.02

A/C PRESSURE MONITOR INSTALLATION INSTRUCTIONS SYSTEM OPERATION GREEN INDICATOR LIGHT

PVI 1800/PVI Residential/Commercial Grid-Tied Photovoltaic Inverter WARRANTY MANUAL. Subject to Change REV , Solectria Renewables

INSTRUCTION MANUAL. Rotary Unidirectional Piezoelectric Motor Evaluation Kit. (Model: UPM-28) Made in USA

VP-6124/VP-6124-E 24 VOLT DC SWITCHING POWER SUPPLY

DUAL WIDEBAND AIR/FUEL RATIO GAUGE Product Numbers: GS-W702W_Dual, GS-C702W_Dual, GS-T702W_Dual

PH21/27 POWERHOUSE Dual Generator Parallel Kit Operating Instructions

Charging with AC (wall) Charger

EN120 EN180. Owner's Guide Conforms to / Conforme à UL std. 458, Toll Free

SELECT/DIRECT DEMO BOX USER GUIDE. INST164 Doc 1.00

TECHNICAL INFORMATION

1200+ WITH LVD (LOW VOLTAGE DISCONNECT) USER GUIDE

StormPro BA Series Sump Pump

TPHK Series Immersible Pump

Grid Tied Limiter User Manual

Manual Tank Valve Remote Shutdown Actuator

AIR VELOCITY METER ALNOR MODEL AVM410 AIRFLOW INSTRUMENTS MODEL TA410

MV Series Motors Operation & Parts Manual. Models M3V, M5V, M5V-US

GENERATOR START CONTROL MODULE

SUPER PUMP OUT SYSTEM

Operation Manual. English. APC Smart-UPS VA 3U Rack and Stack Uninterruptible Power Supply 230 Vac , Revision 1 12/00

Intelligent Flap Controller

WARNING. Instructions for Guidelights and Chargers. How SnapPower Products Work

Auto-Trol Limited 1660 SW 196th Avenue * Aloha, OR 97003

All products subject to this warranty must be returned for examination, repair or replacement to:

Subject Underhood G System Error Codes and Symptoms System or Parts affected

Active Controlled Cooling System

GENERATOR START CONTROL MODULE

User s Manual. Item no. 2561

MaxLite LED UTILITY WRAP FIXTURES

Owner s Manual Supplement. Liquefied Petroleum Gas (LPG) Fuel System for 1998 GM Medium Duty Chassis (C-60/C-70) with 6.0L and 7.

INW Panel Meter Reading an INW PT12 Sensor

USB Charging Station featuring Qualcomm Quickcharge 2.0 technology

PD404-AN V analog control 4 Channel x 500 W Dimmer & Switch Packs ANALOG 0-10 V. Serial Number

200w Performance Series 2-CH Amplifier Kit For Harley Street Glide/Ultra/Ultra LTD. Fairing JMAA-2000HC14

Owner s Guide ca4053 ca4553

TS400Q TS800Q. Auto Pressure Control Pump Instruction Manual. ISO 9001 Certified Walrus America Inc

Table of Contents. How the Surestart SE 433 Operates Starting the Vehicle with the Remote Starter... 3

CBC-160-1N and CBC-160-2N Clutch/Brake Controls

Tekleen GB6 & GB7 USERS AUTOMATIC FILTERS, INC. MANUAL

Transcription:

CHIP Reverse Osmosis System Controller Documentation Document Revised June, 2017. 2017 icontrols Technologies Inc icontrols Technologies Inc. 1821 Empire Industrial Court, Suite A Santa Rosa, CA 95403 ph (425) 577-8851 www.icontrols.net

Welcome. Thank you for purchasing an icontrols RO controller. You made a good choice in choosing icontrols. You can expect years of trouble-free service. With a design based on feedback from leaders in the RO field plus our own experience in RO system design and manufacture, icontrols RO controllers are truly best in class. As good as our controllers are, there s always room for improvement. If you have an experience, idea or input either positive or negative we d love to hear from you. Again, thanks for your purchase. Welcome to the community of icontrols users. David Spears President, icontrols Technologies Inc. david@icontrols.net 2017 icontrols Technologies Inc. 2

Table of Contents Description Page Specifications: Table 1 4 Controller Overview: Figure 1, 1a 5-6 Controller Detail: Figure 2 7 Controller Detail: Figure 3, 3a 8-9 Program Settings: Figure 4 10 Controller Programming: CHIP Program Selections 11 Controller Programming: Parameters Explained, Appendix A 12-13 Programming Interface, Appendix B 14 Warranty 15 2017 icontrols Technologies Inc 3

Table 1. Specifications Inputs Tank level switch Inlet pressure switch Pretreat lockout switch Controller Power (1) Normally-Closed. RO Runs on switch closure. Normally-Open. Switch opens on low pressure. Normally-Open. Pretreat lockout active with switch closure. NOTE: All switch inputs are dry contacts. Voltage applied to the switch inputs will damage the controller. 120/240 VAC, 60/50Hz (Range: 96-264 VAC) The switching power supply automatically adjusts to supply voltage. Voltage applied to the input is the same voltage the motor and valves will operate on. Relay Output Ratings Feed Solenoid 12A. Output Voltage is the same as motor/supply voltage. Flush Solenoid 12A. Output Voltage is the same as motor/supply voltage. The solenoid relay ratings above reflect the capacity of the relays only. The current capacity of each circuit is 2A. Motor 1.0 HP @ 120V, 2.0 HP @ 240V. Circuit Protection Controller Power Fuse F1 5x20mm 1/4 (0.25) Amp LittleFuse 0218.250MXP Branch circuit protection, motor and valve protection must be provided externally. Other Dimensions Weight Environment 7 tall, 5 wide, 2.375 deep. Nema 4X Polycarbonate Enclosure. 1.1 lb. 0-50 C, 10-90%RH (non-condensing) 2017 icontrols Technologies Inc. 4

Figure 1. Controller Overview-Vertical Solid Green= Tank Full Flashing Red= Standby Off= RO Running Solid Green= Valve Open Flashing Green= Startup Delay Solid Green= RO Running Solid Green= System Flushing Flashing Red= Pretreat Lockout Solid Red= Low Pressure Flashing Red= Low Pressure-restart delay Standby/ON Switch Capacitive touch switch. Tank Full LED turns Red to confirm button contact. To use switch to switch states, hold for 1-2 seconds. 2017 icontrols Technologies Inc 5

Figure 1a. Controller Overview, Horizontal option The CHIP controller is also available in a horizontal orientation. The features are identical to the Vertical Orientation shown on the previous page. 2017 icontrols Technologies Inc. 6

Figure 2. Controller Detail Switching Power Supply Operates on 96-264VAC, adjusts automatically to line voltage. Voltage at the supply terminals is the voltage for the pump and valves.. Programming Port Standard USB port for connection to computer for programming. DIP Switches Select RO Program Switch System ON/Standby 2017 icontrols Technologies Inc 7

Figure 3. Controller Detail-Vertical Pump/Motor 110-240 VAC Supply Power 110-240 VAC Inlet Valve 110-240 VAC Flush Valve 110-240 VAC USB Port DIP Switch RO Program Selection ON/Standby Switch Capacitive touch sensor. Pressure Switch Pretreat Switch Tank Switch Switch Inputs Dry Contact Only icontrols.net 2017 icontrols Technologies Inc. 8

Figure 3a. Controller Detail-Horizontal ON/Standby Switch Capacitive touch sensor. DIP Switch RO Program Selection USB Port icontrols.net Tank Switch Pretreat Switch Pressure Switch Flush Valve 110-240 VAC Inlet Valve 110-240 VAC Supply Power Pump/Motor 110-240 VAC 110-240 VAC Switch Inputs Dry Contact Only 2017 icontrols Technologies Inc 9

Figure 4. DIP Switch Settings See Page 9 for details on the RO Program settings. J5 RO Program Settings Switch 1 Switch 2 Program OFF OFF 1 ON OFF 2 OFF ON 3 ON ON 4 2017 icontrols Technologies Inc. 10

Table 2. Controller Programming: CHIP Program Selections The controller has 4 separate user-selectable sets of settings for configuring the RO. The factory default settings are shown below. The settings are identical except for variations in the flush behavior. Program 1, High Pressure flush. Program 2, No Flush Program 3, Permeate Flush, (low pressure, inlet valve closed) Program 4, Low Pressure, feed water flush See the previous page for instructions on how to select these programs. See Appendix A for a detailed explanation of the Parameters and their affect on the RO s operation. See Appendix B for information on the programming interface for use in modifying these settings. Parameter Value Program 1 Program 2 Program 3 Program 4 Tank Level Switch delay (actuation and de-actuation) Seconds 2 2 2 2 Pressure Switch delay (actuation and de-actuation) Seconds 2 2 2 2 Pretreat Switch delay (actuation and de-actuation) Seconds 2 2 2 2 Pump start delay Seconds 10 10 10 10 Inlet Solenid stop delay Seconds 1 1 1 1 Pump start retry interval (restart delay after LP fault) Seconds 60 60 60 60 Low pressure fault shutdown, # of faults Faults 5 5 5 5 Low pressure fault shutdown, time period to count faults Minutes 10 10 10 10 Low pressure fault shutdown, reset after shutdown Minutes 60 60 60 60 Low pressure timeout fault Seconds 60 60 60 60 Flush Behavior High Pressure No Flush Permeate Flush Low Pressure Flush Startup Flush: Minutes from last flush Minutes 0 0 0 0 Startup Flush: Duration Seconds 0 0 0 30 Periodic Flush: Interval Minutes 60 0 0 0 Periodic Flush: Duration Seconds 30 0 0 0 Shutdown Flush: Time from last flush Minutes 10 0 0 0 Shutdown Flush: Minumum operation Minutes 30 0 0 0 Shutdown Flush: Duration Seconds 60 0 60 60 Idle Flush: Interval * Minutes 0 0 0 0 Idle Flush: Duration * Seconds 0 0 0 0 * These features are disabled by default due to the potential for confusion on the part of end-users in the field. They can be enabled when needed via the OEM PC programming interface which allows changes to all of the values shown above. 2017 icontrols Technologies Inc 11

Appendix A. Controller Programming: Parameters Explained Parameter Value Range Example Input Switch Behaviors Tank Level Switch delay (actuation and de-actuation) Seconds 2.0 This specifies the time that the tank switch must be closed or open before the controller accepts it as a valid condition. The function is to prevent nuisance tripping of the RO especially in small tanks or turbulent tanks Pressure Switch delay (actuation and de-actuation) Seconds 3 This specifies the time that the pressure switch must be closed or open before the controller accepts it as a valid condition. Since pressure switches usually have built-in hysteresis this value is set at 0. Pretreat Switch delay (actuation and de-actuation) Seconds 2 This is the time that the pretreat switch must be OPEN before the controller accepts it as a valid condition. Pump/Inlet Solenoid Behaviors Pump start delay Seconds 10 On RO start-up, after the tank switch opens, the inlet solenoid valve is energized. When the inlet pressure switch closes this begins the Pump start delay. If the pressure switch remains closed, the pump will start after 10 seconds. Inlet Solenid stop delay Seconds 1 This value sets the delay for the inlet solenoid valve to be deenergized following the deenrgizing of the motor on RO shut down. The purpose is to prevent the pump from operating against a closed suction as the pump spins down. Low Inlet Pressure Behaviors Pump start retry interval (restart delay after LP fault) Seconds 60 When the inlet pressure swith opens, the controller deenergizes the motor and the inlet solenoid valve remains open. The controller will continure to monitor the inlet pressure switch. After the switch is closed for the duration of the Pump start retry interval the motor is reenergized. Low pressure fault shutdown, # of faults Faults 5 Low pressure fault shutdown, time period to count faults Minutes 10 Low pressure fault shutdown, reset after shutdown Minutes 60 These three values work together to determine how the RO handles Low Pressure conditions. The first two values, # of faults and time period to count faults, sets the limit for the number of low pressure fault conditions over time that are required to place the RO in Low Pressure Fault Shutdown. The third value sets the duration of the Low Pressure Fault Shutdown which is the period that the RO will remain idle before trying to restart. The purpose of the Low Pressure Fault Shutdown is to prevent an RO from turning OFF/ON repeatedly without any limit. Low pressure timeout fault Seconds 60 If the inlet valve is open, but the pressure isn t sufficient to close the inlet pressure switch, the RO would run indefinitely on line pressure. This value sets the time limit for the RO to operate with the inlet valve open with Low Pressure as indicated by an Open inlet pressure switch before a Low Pressure Fault is added to the counter above 2017 icontrols Technologies Inc. 12

Appendix A. Controller Programming: Parameters Explained Flush Behavior Time from last flush before Flush on Shutdown Minutes 15 Minimum operation before Flush on Shutdown Minutes 60 Flush duration on Shutdown Seconds 60 Periodic Flush interval Minutes 60 Periodic Flush duration Seconds 30 Unit Idle Flush interval * Minutes 0 The Unit Idle Flush Interval sets a time after which the RO will start-up and run in the flush mode. This is disabled by default because of the danger of over-flowing a tank if not properly implemented. It is intended for environments where leaving the RO idle for long periods would invite bio-fouling. (0)=disabled Unit Idle Flush duration * Seconds 0 Sets the duration of the Idle Flush. (0)=disabled 2017 icontrols Technologies Inc 13

Appendix B. Programming Interface The Programming interface is a Windows-based tool for making changes to the CHIP software. This screen shows the RO settings available. There are 4 field-selectable sets of settings stored in the CHIP. 2017 icontrols Technologies Inc. 14

Appendix C. Warranty icontrols Limited Warranty What the warranty covers: icontrols warrants the CHIP controller to be free from defects in materials and workmanship during the warranty period. If a product proves to be defective during the warranty period, icontrols will at is sole option repair or replace the product with a like product. Replacement product or parts may include remanufactured or refurbished parts or components. How long the warranty is effective: The CHIP is warranted for one (1) year for parts and labor from the date of the first consumer purchase or 15 months from ship date, whichever comes first. What the warranty does not cover: 1. Damage, deterioration or malfunction resulting from: a. Accident misuse, neglect, fire, water lightning or other acts of nature, unauthorized product modification or failure to follow instructions supplied with the product. b. Repair or attempted repair by anyone not authorized by icontrols c. Any damage of the product due to shipment. d. Causes external to the product such as electric power fluctuations. e. Use of supplies or parts not meeting i-controls specifications. f. Normal wear and tear. g. Any other cause which does not relate to a product defect. 2. Transportation costs necessary to obtain service under this warranty. 3. Labor other than factory labor. How to get service: 1. To obtain warranty service, contact icontrols for a Return Material Authorization (RMA). 2. You will be required to provide: a. Your name and address b. A description of the problem 3. Package the controller carefully for shipment and return it to icontrols, freight prepaid. Limitation of implied warranties: There are no warranties, expressed or implied, which extend beyond the description contained herein including the implied warranty of merchantablility and fitness for a particular purpose. Exclusion of damages: icontrols liability is limited to the cost of repair or replacement of the product. icontrols shall not be liable for: 1. Damage to other property caused by any defects in the product, damages based upon inconvenience, loss of use of the product, loss of time, loss of profits, loss of business opportunity, loss of goodwill, interference with business relationships or other commercial loss, even if advised of the possibility or such damages. 2. Any other damages, whether incidental, consequential or otherwise. 3. Any claim against the customer by any other party. Effect of state law: This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow limitations on implied warranties and/or do not allow the exclusion of incidental or consequential damages, so the above limitations and exclusions may not apply to you. 2017 icontrols Technologies Inc 15