INSTRUCTION MANUAL BGI 400. Personal Sampler Pump

Similar documents
OPERATING MANUAL. June 2003

ESCORT LC Pump. Instruction Manual WARNING

Buck BioAire Model B520 Instruction Manual

Universal Pump Cat. Nos XR, 224-PCXR4, and 224-PCXR8

MODEL 901 OPERATING INSTRUCTIONS

Operating Instructions AirLite Sample Pump Cat. No SKC Inc. 863 Valley View Road Eighty Four, PA 15330

04979, 04980, 04981, 04982, 04983, 04984, 39054, 39055, 39056, 39057, 39225, 81459,

7007 Loop Mate 2 Loop / Voltage / Current Simulator

KV4-300 mk2. KV5-200 mk2. KV5-100T mk2. KV3-250 mk2

OPERATION & SERVICE MANUAL

Battery Powered Hydraulic Pump; Kit PN [ ]

Maintenance Manual 3-INCH INTERNAL VALVE F660 SERIES

Ph: (07) Fax: (07) Pump Manual

MODEL 905V OPERATING INSTRUCTIONS

ESCORT ELF and ESCORT LC SAMPLING PUMPS

The EFL 2000/1 & 2 User Guide Test Sieve Shaker. Contents

Universal Sample Pump Catalog No. 224-PCXR4

Instruction Manual AVTM for. Strip Chart Recorder Catalog Nos and

BGI 58 Guinan St. Waltham, MA V: F:

Model 2310 Series. Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Maintenance Manual. 3-Inch Internal Valve. F660 Series

Pump inlet (inlet fi lter underneath) Top view. Figure 1. AirChek 52 Sample Pump

PROCESS ELECTRONICS CORPORATION

JACKALL HYDRAULIC SYSTEM

Buck BioSlide Model B1020 Instruction Manual

Battery compartment door. Belt clip (back of pump) Front view Top view. Figure 1. AirLite Sample Pump

Model 340 Tune-Up Kit Instructions

2.- HANDLING OF VALVES BEFORE ASSEMBLY 3.- FITTING THE VALVE TO THE REST OF THE ASSEMBLY 5.- PERIODICAL INSPECTION OF THE VALVE AND MAINTENANCE

National Board Update

DCell Suction. Model DM Operating Instructions & Maintenance Manual. Clearing The Airway Is Our #1 Priority

Embedded Rack Slide-out System

#9040 FUEL TANK SWEEPER

RP-4000 Reserve Power Control

EMERGENCY EGRESS LIGHTING POWER SUPPLY BATTERY

CBC-300 Series & CBC-300C Series Dual Channel Adjust Clutch/Brake Controls

GPM Hydraulic Flow Meter User Manual

OFX7 Operating Maintenance and Troubleshooting Manual L-4219

INSTRUCTION MANUAL FOR THE THERMOCOUPLE ATTACHMENT UNIT (TAU)

Reproduction or other use of this Manual, without the express written consent of Vulcan, is prohibited.

Optima ETF-600/ETF-610

LNW-5. Installation... 2 Lift Truck Conditions Indicator Installation Hose Installation

KEEP FOR FUTURE REFERENCE DC VACUUM BACK-UP SYSTEM READ ALL INSTRUCTIONS AND WARNINGS BEFORE USING THIS PRODUCT

Maintenance Manual WATER SUMP CONTROL VALVE F532B

Operating Instructions & Parts Manual

OWNER S MANUAL. Model: LG-30-TRL ( ) (30 Gallon Lawn & Garden Trailer Sprayer)

MODEL 7100 PORTABLE PIN WELDER OPERATOR S MANUAL

EV-2051-M Electric Motor. Operation and Maintenance Manual

Convertible - Rated 3 4-Ton /2-Ton Nylon Strap Hoists Refer to any questions about the use, application, repair or testing of this hoist to:

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Figure 1. AirChek XR5000 Air Sample Pump

FAIRCHILD T5420 DIGITAL-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

1. INTRODUCTION AND SYSTEM DESCRIPTION BLOCK DIAGRAM GENERAL INFORMATION GLOSSARY... 7

LBC Series Battery Charger Instructions

Troubleshooting Guide: 255 LED Light

INSTALLATION, OPERATION AND MAINTENANCE INSTRUCTIONS

MotorScrubber MS2000S/M/L Instruction Manual

8,1,8,1,2,7,2,7,6,3,6,3,4,5,4,5

Operating Instructions. High Energy Vibratory Finishing Bowl. Model FSV-25/50. Vibra Finish Company

Universal Sample Pump

FAIRCHILD T5220 SERIES ELECTRO-PNEUMATIC TRANSDUCER Installation, Operation and Maintenance Instructions

Bio-Pump Plus. Operating Instructions. Product # ZBP-200. Description. Specifications

PROwatt 150 DC to AC Power Inverter. Owner s Guide

OPERATING AND MAINTENANCE MANUAL. Primary Current Injection Test Set. 750ADM-H mk2

INSTALLATION, OPERATION, MAINTENANCE MANUAL FOR MANUALLY OPERATED STOP CHECK VALVE

A2P Single Phase Automatic Industrial Battery Charger

Operation and Maintenance Manual for BS and BH Hydraulic Torque Wrenches

MGM Brakes Service Manual

103 Differential Pressure Switch

SM64052 Maintenance & Repair Manual Commercial 2" Unisex Coupling - Valved Model 64052

HVF110, 210, 310, 410HD

CHAPTER 22 STARTER Models J05C-TD, J08C-TP and TR

H-10G Refrigerant. Leak Detector

ACHL Series Pump. Operation and Maintenance Manual Air Driven, Hand Operated High Pressure Liquid Pump

Optima ETF-500. Hand Hygiene. Repair Parts and Maintenance Guide PARTS LIST ETF-500 FAUCET ETF-500. See page 157 for faucet cable extension cords.

MARTINDALE INSTRUCTIONS ELITE FUSE FINDER KIT ELECTRIC. Trusted by professionals. 4.4 Storage Conditions

Maintenance Instructions

GENERAL INFORMATION. INSTRUCTIONS FOR 500A Lithium Jump Starter

Operating and Installation Instructions Diaphragm Vacuum Pumps and Compressors

200 Shadylane Drive Philipsburg, PA Phone: (814) Fax: (814) Service Manual. Model 642E Centrifuge

LM-200 MECHANICAL LUBE METER Owner s Manual

PARTS CATALOGUE / TECHNICAL GUIDE

MD10. Engine Controller. Installation and User Manual for the MD10 Engine Controller. Full Version

DC REGULATED POWER SUPPLY

INSTRUCTION MANUAL CAT Bio-Pump Plus

WESCO INDUSTRIAL PRODUCTS, INC. Heavy Duty Semi Electric Pallet Truck. Part Number:


MR 5-30 or MR 5-30N Series Fuel Meter Owner s Manual

MotorScrubber MS2000S/M/L Instruction Manual

HT Dielectric Withstand Tester Volts AC Output 25mA Leakage Option

H.S. MACHINERY RING COMPRESSORS

Jerome DOSIMETER POCKET PUMP OPERATOR S MANUAL

Maintenance Information

SERIES G3DB/AG3DB ELEVATOR

Service Bulletin Trucks Date Number Page


MODEL 422 Submersible Pump Controller

TILLOTSON LTD., CLASH INDUSTRIAL ESTATE, TRALEE, CO. KERRY, IRELAND PHONE: FAX:

Model Differential Sticking Tester Instruction Manual

DUAL LINEAR MOTOR / ACTUATOR CONTROLLER W/ CURRENT SENSING AUTO REVERSE

PARTS LIST / TECHNICAL GUIDE Perpetual Calendar/Alarm Chronograph Cal. 7T86A

Transcription:

INSTRUCTION MANUAL BGI 400 Personal Sampler Pump BGI Incorporated 58 Guinan Street Waltham, MA 02451 Ph: 781-891-9380 Fax: 781-891-8151 http://www.bgiusa.com e-mail: info@bgiusa.com Version 1.4 Feb 2010

BGI 400 Personal Air Sampling Pump 1.0 APPLICATION To collect a sample of a contaminant from the air (preferably in the breathing zone). The choice of sampling head lies with the investigator. However, the BGI-400 was designed for use with the BGI/KTL cyclone which operates at 4 Lpm and provides a (PM) 2.5 size cut. Utilizing the KTL Cyclone fitted with a 37 mm cassette loaded with 0.8 µm MCE membrane, 24 hour samples is readily accomplished. 2.0 CONSTRUCTION The aluminum case houses a double diaphragm pump, double pulsation dampners, electronic control board and an elapsed time indicator with a Lithium battery back up. External controls comprise an on/off switch, flow rate setting potentiometer and an access hole for resetting the elapsed time indicator. The entire inside of the case is lined with sound deadening material which results in essentially silent operation. 3.0 SAMPLING This instruction manual describes how the sampler works and how to maintain it. It does not detail how to sample, or how to analyze collected samples nor how to select methods for various investigations. The BGI instruction manuals for various sampling heads contain the information on their usage. The battery must be fully charged to insure a 24 hour run. Full charging is achieved by connecting the battery to its charger and allowing a 16 hour period to elapse. NOTE: The sampler should never be run without a filter on the inlet. A suitable filter is put into the appropriate holder and is connected by a length of plastic tube to the inlet of the sampler. Switch the pump ON using the slide switch located in the recess in the back of the case. A flashing light indicates that the pump is running. Setting of the flow rate is by adjustment of the potentiometer marked FLOW on the back of case. Turn clockwise to increase the flow rate. In order to check the pump calibration prior to sampling, it is only necessary to connect a suitable rotameter (BGI Part No. RM67, 2-20 Lpm), a bubble meter or the BGI TetraCal (formally trical) (BGI Part No. TC-5) to the filter inlet as shown in Figure 1. Adjust the FLOW screw to the desired sampling value, which will then remain constant within the specified limits of flow rate and pressure drop for any sampling head and filter. It is advisable to run the pump for 10 minutes before checking flow rate. 2

If it is desired to check the limits of pressure drop increase to which a filter can be utilized, then an optional valve and pressure gage should be inserted in the system. By closing the valve (and increasing the pressure drop), you are simulating an increasingly dirty filter. However, it should be emphasized that this is not a required procedure and is only presented as a matter of interest. When the flow rate has been set only routine checking is required as long as no change in flow rate is required. For personal monitoring, attach sampling head in person s breathing zone. Do not neglect to reset the elapsed time indicator before sampling. This is accomplished by inserting a pin through the hole located near the display screen. When sampling is to be ended, check flow rate, switch off and note time. The flow should be within +/- 5% of original setting. Put battery on charge using charger. To evaluate collected sample unload sampling head in the appropriate way, dispatch to laboratory with details of time, flow rate, location, probable contaminant, likely concentration and any other relevant points. Check List Before Sampling Make sure the battery has been fully charged. Insure sampling head is correctly fitted with no leaks. If flow rate cannot be obtained with similar conditions to previous occasions, suspect leakage. Operational Run Time Limits The BGI 4004, with 24 hour battery will run more than 24 hours against a resistance of 45 cm of H 2 O at 4 Lpm. It will run more than 24 hours against a resistance of 40 cm of H 2 O at 5.2 Lpm. Double those run times will be achieved with the 48 hour battery. 3

4.0 MAINTENANCE Keep a record of hours used and replace parts at intervals: Part Replacement Interval in Hours Valves 2000 Pump diaphragm 2500 Dampner 2500 Ball Bearing on eccentric 4000 Motor 4500 NOTE: If above maintenance is carried out, failure to obtain a sample should be very infrequent. If conditions of use are in dusty surroundings or are in rough handling locations, replacement intervals may be shorter. 4.1 SERVICING It is highly recommended that repairs and service are carried out at BGI, by trained personnel. Nevertheless, it is recognized that there may be reasons or need for user performed servicing. 4.1.1 PUMP UNIT - FIGURE 2 1. Remove the four screws, remove case lid shown in Figure 2. 2. Lift out the pump unit together with the circuit board to avoid straining the motor connection to board. 4.1.2 VALVES - FIGURE 3 1. Remove the double valve chest. Note position and method of securing valves and discard. 2. Examine valve seat C. Use non-metallic probe- for example, wooden toothpick to remove dirt. Use care at valve edge. 3. Fit new valves. Replace valve chest. Do not use too much pressure when tightening screws. 4. Brush any dust from the ball bearing in eccentric. Put one drop of lubricant on motor bearing. 4

4.1.3 PUMP DIAPHRAGM FIGURE 3 Diaphragm should be replaced at the recommended interval or if the slightest damage is suspected. First follow the steps in section 4.1.2 and 4.1.3 but do not reassemble. A. Withdraw the screw, now visible in the center of the support disk. Withdraw the diaphragm and both support disks. Note direction of convolution in diaphragm and replace new diaphragm in the same direction. B. Reassemble in reverse order and attend to the opposite side of the pump. 4.1.4 MOTOR AND BEARINGS It is not recommended that the replacement of the bearings on the eccentric shaft be attempted. The bearings and eccentric are available as a complete assembly. A. Remove valve chests, clamp rings and diaphragm as above. B. Loosen set (Grub) screw and withdraw eccentric and bearings as a complete assembly. C. Remove three screws holding motor in place and withdraw motor from chassis. D. Carefully unsolder electrical leads from old motor and transfer to new motor. E. Reassemble in reverse order. 4.1.5 ELECTRONIC CONTROL CIRCUIT - FIGURE 4 If the pump does not run carry out the following checks A. That battery voltage appears at the input terminals of the control board. B. That a voltage appears at the motor terminals. If no volts at input, check battery and connections. If no volts at the motor terminal, the control board should be replaced. 5

4.1.6 SETTING THE CONSTANT FLOW COMPENSATION CIRCUIT - FIGURE 5 As the pump unit is received from the factory, the circuit is properly set up for 4 Lpm. The following information is presented for checking purposes or when other than factory repairs have been effected. NOTE: The pump is set to give the minimum variation in flow rate against a pressure drop at 4 Lpm. And at this setting there will be very little change in flow rate. It may be necessary to make minor adjustments to the trimmer potentiometer, VR2, Figure 4, to obtain the ± 5% accuracy at 4 Lpm. For greater accuracy at any flow rate within the range, this procedure should be followed using the required flow rate at the datum. Referring to Figure 5, set the shut off and load valve fully open. Adjust the FLOW potentiometer (VR1) to the desired flowrate (say 4 Lpm) and allow one minute to stabalize. Close the shut off valve and close down the load valve until a pressure drop of approximately 15 inches H 2 O back pressure is achieved. If necessary, adjust the potentiometer VR2 to bring the flow back to the desired figure (in this case 4 Lpm). Open the shut off valve. If the flow has altered from the set point (4 Lpm), reset with potentiometer VR1 (FLOW) and repeat the above procedure. 4.1.7 DAMPNERS - FIGURE 2 The Dampners are a glued up assembly and are not user reparable. The complete dampner assembly may be returned to the factory for rebuilding or a complete new assembly acquired. 4.1.8 BATTERY CHARGE This component has an extremely long life and is not a servicable item. If inoperative, replace. NOTE: If, after replacement of a part, performance is not regained it is usually an indication some procedure has not been carried out correctly or that there is a small leak. Most common cause of poor performance is in the valve. They must be flat and aligned on valve seat. 6

5.0 ALTERATIONS WITHOUT NOTICE The contents of this manual are subject to alteration without notice. As specifications and design of instruments are under continual review, illustrations and descriptions should not be taken as correct in every detail. 6.0 FAULT TRACING Your personal sampler is designed and engineered for long distance and dependable service but as a precision instrument it should be given the best of care. Typical problems are shown on the accompanying chart. When testing, refer to the exploded views contained in this manual. Other than service hints outlined in the instruction manual, we recommend factory service by technicians trained and equipped to repair your sampler. Should you wish factory repair assistance obtain an RMA from our website (www.bgiusa.com), pack your sampler in a carton equal to the original packaging. Insure to full value and ship prepaid. Include a letter giving full details with your packing list. SYMPTOM POSSIBLE CAUSE SERVICE HINT Pump does not run Battery fully discharged Replace with fully charged battery LED not illuminated Wiring loom disconnect at some point Fault on circuit board Locate and resolder joint Replace Pump does not run LED illuminated Eccentric bearing seizure Motor shaft seizure Replace Replace motor Motor runs but pump inoperative Set screw securing eccentric to motor shaft loose Retighten Pump runs but no air drawn Diaphragm rubber split Replace Pulsation dampner membrane split Renew pulsation dampner 7

Flow potentiometer on bottom setting Tube between pulsation dampner and valve chest split or disconnected Readjust Replace Pump runs but cannot achieve flowrate Leak on pump assembly Dirt under valves or valves damaged Flow potentiometer inoperative Locate and correct Replace Replace circuit board Cannot obtain full cycle working even when pressure drop does not exceed 15 ins H 2 O Incomplete charge Battery below capacity End of battery service life High current consumption due to mechanical defect in pump Recharge Fully charge Replace battery Locate and correct 8

7.0 BGI-400 PARTS LIST BGI PART # DESCRIPTION QUANTITY FIGURE 400A Pump Motor Assembly 3-6 Lpm 1 2 DA1 Dampner Assembly 1 2 TPCB400 Timer Board 1 2 PPCB400 Pump Board 1 2 HS-02 Connector Tubes 2 2 HS-01 Connector Tube 1 2 SW52 On/Off switch 1 2 7576/A28 Belt Clip 1 2 A1793 Belt Clip Spacer 1 2 A2005 Inlet Tube 1 2 BNC1 Electric Connector 1 2 B-01 LED 1 2 SPC-01 TPCB400 Spacers 2 2 SC-01 TCPB400 Screws 2 2 NUM-161 TCPB400 Nuts 2 2 SM912-8 Switch Screws 2 2 NUM160 Switch Nuts 2 2 SC-03 Belt Clip Screws 2 2 SC-02 PCB Holder Screws 4 2 NUM162 Belt Clip Nuts 2 2 A1792 PCB Holder 1 2 A2125 Valve Chest 2 3 A1956 Valve 2 3 A1955 Valve Seat 2 3 10057 Diaphragm 2 3 7806-1A10 Diaphragm Support Disk 4 3 9

A1630 Yoke 1 3 BGI PART # DESCRIPTION QUANTITY FIGURE MO-50 Motor 1 3 A1496/2 Eccentric/Bearing 1 3 Assembly 3-6 Lpm HK-2 Eccentric Set Screw 1 3 SM1824-8 Motor Mount Screws 3 3 400-1A Diaphragm Screws 2 3 SM2130-8 Valve Seat Screws 8 3 SM1736-8 Valve Chest Screws 12 3 A1946 Pump Body 1 3 10

Figure 1: Schematic of Flow Setting and Testing Circuit 11

Figure 2: BGI 400 (Only numbered components available for replacement) 12

Figure 3; Pump Assembly. (Only numbered components available for replacement) 13

Figure 4: Main PCB 14

Figure 5: Schematic of Apparatus for Testing and Setting Electronic Flow Regulation Circuit 15

Revision History Version 1.0 Manual Published February 1999 Version 1.1 Corrections, additions February 2002 Version 1.2 Added TetraCal May 2007 Version 1.3 Removed obsolete items September 2009 Version 1.4 Updated Fig. 2, 3 & 4 February 2010 16